Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 853
Filter
1.
Clin Exp Dent Res ; 10(4): e924, 2024 Aug.
Article in English | MEDLINE | ID: mdl-39016106

ABSTRACT

OBJECTIVES: The aim of this in vitro study was to investigate whether and to what extent different scenarios of rotational freedom in different IAC designs affect the vertical dimension of a three-part fixed partial denture (FPD). At the same time, the experimental setup should simulate all clinical and laboratory steps of the implementation of such an FPD as accurately as possible. MATERIAL AND METHODS: Twenty identical pairs of jaw models were fabricated from aluminum, each lower-jaw model holding two implants with conical or flat IACs. Three impressions of each model were taken to fabricate stone casts and three-unit FPDs. Three assembly scenarios were compared for the vertical position stability they offered for these FPDs, differing by how the sequential implant components (impression posts > laboratory analogs > abutments 1 > abutments 2) were aligned with the positional index of the IAC. In this way, a total of 60 stone casts and FPDs were fabricated and statistically analyzed for changes in vertical dimension (p < 0.05). RESULTS: Regardless of whether a conical/flat IAC was used (p > 0.05), significantly greater mean changes in vertical dimension were consistently (all comparisons p < 0.0001) found in a "worst-case scenario" of component alignment alternating between the left- and right-limit stop of the positional index (0.286/0.350 mm) than in a "random scenario" of 10 dentists and 10 technicians with varying levels of experience freely selecting the alignment (0.003/0.014 mm) or in a "best-case scenario" of all components being aligned with the right-limit stop (-0.019/0.005 mm). CONCLUSIONS: The likelihood of integrating a superstructure correctly in terms of vertical dimension appears to vary considerably more with assembly strategies than with IAC designs. Specifically, our findings warrant a recommendation that all implant components should be aligned with the right-limit stop of the positioning index.


Subject(s)
Dental Prosthesis, Implant-Supported , Denture, Partial, Fixed , Humans , Dental Prosthesis, Implant-Supported/methods , Rotation , Models, Dental , Dental Abutments , Vertical Dimension , Dental Implant-Abutment Design/methods , Dental Implants , In Vitro Techniques , Dental Impression Technique/instrumentation
2.
Int J Implant Dent ; 10(1): 31, 2024 Jun 10.
Article in English | MEDLINE | ID: mdl-38856842

ABSTRACT

PURPOSE: Prosthetics for patients after oncological resection of the upper jaw is a complex problem associated with the physiological and anatomical separation of the oral cavity and the nasal/paranasal region. This study reports the clinical results of the use of the zygomatic implants for prosthetic rehabilitation in patients with maxillectomy due to upper jaw tumors. MATERIALS AND METHODS: The study included 16 patients who underwent prosthetic rehabilitation using a zygomatic implant after maxillectomy period from 2021 to 2023. After the tumor was removed, immediate surgical obturators were placed. Main prosthetic rehabilitation was performed 6-12 months after tumor removal, but before that, a temporary obturator was made and used. Six-twelve months after tumor resection, 1-4 zygomatic implants were inserted into the zygomatic bone unilaterally or bilaterally. A total of 42 zygomatic implants were installed, 2 of which were unsuccessful and were removed in 1 patient. The implants were placed using the surgical guide, which was planned and prepared digitally. RESULTS: No postsurgical complications were seen, and the patients were discharged from the hospital after 7-10 days. The patients were able to return to a normal diet (hard food) after just 7 days following surgery, with no further complaints regarding function or pain, apart from the residual edema caused by the intervention. CONCLUSIONS: The use of prostheses fixed on zygomatic implants in patients with maxillary defects is an effective method of prosthodontic rehabilitation in complex clinical cases after maxillectomy.


Subject(s)
Maxillary Neoplasms , Zygoma , Humans , Zygoma/surgery , Male , Female , Maxillary Neoplasms/surgery , Maxillary Neoplasms/rehabilitation , Middle Aged , Adult , Aged , Dental Implants , Maxilla/surgery , Palatal Obturators , Treatment Outcome , Dental Prosthesis, Implant-Supported/methods
3.
Clin Exp Dent Res ; 10(3): e910, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38881222

ABSTRACT

OBJECTIVE: To assess the reliability of implant stability measurements recorded with the Periotest device and to investigate the differences in values when these measurements were taken on implant retained crowns and healing abutments. MATERIALS AND METHODS: Fifty-six implants in eight synthetic bone blocks were used to carry out implant stability measurements using the Periotest device by two different operators. Each block constituted an example of bone of density D1, D2, D3, or D4, and two blocks of each density were used. The healing abutments placed were of a height to allow approximately 6 mm of the implant-abutment complex to be supracrestal and temporary crowns were made to match the dimensions of an average central incisor. Descriptive statistics were used to describe the perio test values (PTVs) at each of the different heights on the implant abutments and implant crowns. Means for each site were calculated and distribution of data assessed using the Kruskal Wallis test. The interclass correlation coefficient (ICC) was used to determine the relationship between the PTVs recorded on the implant abutments and implant crowns. RESULTS: The mean PTV (±standard devidation) recorded across all sites was 5.57 ± 11.643 on the implant abutments, and 12.27 ± 11.735 on the temporary crowns. Excellent/good inter-operator ICCs were recorded for the mid-abutment site in all bone blocks D1-D4 (ICC = 0.814, p < 0.001, ICC = 0.922, p < 0.001, ICC = 0.938, p < 0.001, ICC = 776, p < 0.001). For mid crown sites, ICC between operators was excellent/good only for recordings in D2 bone (ICC = 0.897, p < 0.001). CONCLUSIONS: Periotest device seems to be able to reliably measure implant stability across all types of bones when the implant stability is assessed at approximately 3 mm coronal to the implant platform for abutments and 4.5 mm for implant supported single crowns.


Subject(s)
Crowns , Dental Abutments , Humans , Dental Prosthesis Retention/instrumentation , Dental Prosthesis Retention/methods , Reproducibility of Results , Dental Implants , Dental Prosthesis, Implant-Supported/instrumentation , Dental Prosthesis, Implant-Supported/methods , In Vitro Techniques , Dental Implant-Abutment Design/instrumentation , Dental Implant-Abutment Design/methods , Bone Density
4.
Swiss Dent J ; 134(3): 1-17, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38757922

ABSTRACT

The concept of bilateral cantilevers on a single central implant (T-design) for three-unit implant-supported fixed dental prostheses (ISFDPs) has not been explored nor tested. This technical hypothesis aimed to explore the feasibility of such an approach as a cost-effective alternative to conventional treatments. Careful considerations regarding implant diameter, length, ideal position, occlusal scheme, and bone remodeling are essential to ensure adequate support, stability, and prevention of complications. In this proof of concept, we present a preliminary case with this novel design to replace missing posterior teeth in a patient with narrow bone conditions. In addition, a series of planned investigations and preliminary results, including preclinical studies, are presented to illustrate our concept and its potential clinical implications. Clinically, after two-year follow-up, healthy and stable peri-implant tissues around the ISFDP exemplarily demonstrated excellent stability, functionality, and comfort, which is supported by acceptable fracture resistance data in vitro, suggesting indeed the practical potential and suitability. Thus, we claim that such a treatment modality has the at least theoretical potential to revolutionize implant dentistry by providing innovative and cost-effective treatment options for patients with partial ISFDPs in very specific cases. Of course, further research and evaluations are necessary to validate the clinical implications of this innovative hypothesis. Implementing the 3-on-1 T-bridge approach in partial ISFDPs could offer a promising alternative to traditional methods. If proven successful, this technique may lead to significant advancements in clinical practice, providing a less invasive cost-effective treatment option.


Subject(s)
Dental Prosthesis, Implant-Supported , Humans , Dental Prosthesis, Implant-Supported/methods , Denture Design , Denture, Partial, Fixed , Proof of Concept Study
5.
Medicina (Kaunas) ; 60(5)2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38792903

ABSTRACT

(1) Background: Recent digital workflows are being developed for full-arch rehabilitations supported by implants with immediate function. The purpose of this case series is to describe a new digital workflow for the All-on-4 concept. (2) Methods: The patients were rehabilitated using the All-on-4 concept with a digital workflow including computerized tomography scanning, intra-oral scanning, and CAD-CAM production of the temporary prosthesis, with the 3D printing of stackable guides (base guide, implant guide, and prosthetic guide). The passive fit of the prostheses and the time to perform the rehabilitations were evaluated. (3) Results: The digital workflow allowed for predictable bone reduction, the insertion of implants with immediate function, and the connection of an implant-supported prosthesis with immediate loading. The time registered to perform the full-arch rehabilitations (implant insertion, abutment connection, prosthesis connection) was below 2 hours and 30 min. No passive fit issues were noted. (4) Conclusions: within the limitation of this case series, the digital workflow applied to the All-on-4 concept using stackable base-, implant-, and prosthetic guides constitutes a potential alternative with decreased time for the procedure without prejudice of the outcome.


Subject(s)
Workflow , Humans , Female , Male , Middle Aged , Computer-Aided Design , Aged , Dental Prosthesis, Implant-Supported/methods , Printing, Three-Dimensional , Tomography, X-Ray Computed/methods , Mouth, Edentulous/rehabilitation
6.
Int J Esthet Dent ; 19(2): 140-150, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38726856

ABSTRACT

The present technical article describes a protocol to digitally reproduce the emergence profile of an interim implant prosthesis (IP) and to transfer its macrogeometry into the definitive restoration. The purpose of this protocol was to minimize alterations in the gingival architecture developed during the interim restorative phase of a single implant that could potentially jeopardize its esthetic outcome. The process included obtaining an intraoral scan with the interim IP in situ, a duplicate of this intraoral scan that was used to capture the exact position of the implant, and an extraoral scan of the prosthesis. These data could then be imported into IOS software to create a model where the patients' soft tissue was incorporated with precision, allowing for the fabrication of a definitive crown with an optimal soft tissue adaptation. As there are few articles in the scientific literature that have reported a consistent method to replicate the emergence profile of an interim IP, the present technical article aims to highlight the potential of utilizing the emergence profile of an interim IP created by IOS software.


Subject(s)
Software , Humans , Esthetics, Dental , Computer-Aided Design , Crowns , Dental Prosthesis, Implant-Supported/methods , Dental Restoration, Temporary/methods , Dental Prosthesis Design/methods , Dental Implants, Single-Tooth
7.
BMC Oral Health ; 24(1): 410, 2024 Apr 02.
Article in English | MEDLINE | ID: mdl-38566034

ABSTRACT

BACKGROUND: To clinically compare the effect of the conventional and the digital workflows on the passive fit of a screw retained bar splinting two inter-foraminal implants. METHODS: The current study was designed to be a parallel triple blinded randomised clinical trial. Thirty six completely edentulous patients were selected and simply randomized into two groups; conventional group (CG) and digital group (DG). The participants, investigator and outcome assessor were blinded. In the group (CG), the bar was constructed following a conventional workflow in which an open top splinted impression and a lost wax casting technology were used. However, in group (DG), a digital workflow including a digital impression and a digital bar milling technology was adopted. Passive fit of each bar was then evaluated clinically by applying the screw resistance test using the "flag" technique in the passive and non passive situations. The screw resistance test parameter was also calculated. Unpaired t-test was used for intergroup comparison. P-value < 0.05 was the statistical significance level. The study protocol was reviewed by the Research Ethics Committee in the author's university (Rec IM051811). Registration of the clinical trial was made on clinical trials.gov ID NCT05770011. An informed consent was obtained from all participants. RESULTS: Non statistically significant difference was denoted between both groups in all situations. In the passive situation, the mean ± standard deviation values were 1789.8° ± 20.7 and1786.1° ± 30.7 for the groups (CG) and (DG) respectively. In the non passive situation, they were 1572.8° ± 54.2 and 1609.2° ± 96.9. Regarding the screw resistance test parameter, they were 217° ± 55.3 and 176° ± 98.8. CONCLUSION: Conventional and digital fabrication workflows had clinically comparable effect on the passive fit of screw retained bar attachments supported by two dental implants.


Subject(s)
Bone Screws , Dental Implants , Mouth, Edentulous , Humans , Computer-Aided Design , Dental Impression Technique , Dental Prosthesis Design , Dental Prosthesis, Implant-Supported/methods , Workflow
8.
Head Face Med ; 20(1): 24, 2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38627712

ABSTRACT

OBJECTIVES: A randomized controlled clinical trial of dental implants was conducted to compare the clinical properties of a novel electrochemically deposited calcium phosphate coating to those of a common marketed surface treatment. MATERIAL AND METHODS: Forty implants of the same brand and type were placed in 20 fully edentulous participants requiring mandibular implantation. The two study groups were defined by the surface treatment of the implants. 20 implants in the control group were coated via a commercial electrochemical surface treatment that forms a mixture of brushite and hydroxyapatite, while the remaining 20 in the test group were coated with a novel electrochemical Smart Bioactive Trabecular Coating (SBTC®). A split-mouth design was employed, with each participants receiving one control implant in one mandibular side and a test implant in the other. To mitigate potential operator-handedness bias, control and test implants were randomly assigned to mandibular sides. All cases underwent digital planning, implant placement with a static surgical guide, and participants received locator-anchored full-arch dentures. The primary outcome was implant stability (measured using Osstell ISQ) assessed at insertion, loading, and then 3 months, 9 months, and 2 years post-insertion. The secondary outcome was bone level change (in millimeters) over the 2-year observation period. Oral health-related quality of life (OHRQL) was monitored using the OHIP-14 questionnaire. Complications and adverse events were recorded. RESULTS: Successful osseointegration and implant stability were achieved in all cases, allowing loading. ISQ values steadily increased throughout the observation period. While no significant differences were observed between the SBTC® and control coatings, the test group exhibited a higher ISQ gain. Bone resorption was somewhat lower in the SBTC® but not significantly so. Patients' OHRQL significantly improved after denture delivery and remained stable throughout the follow-up. No complications or adverse events were observed. CONCLUSIONS: Based on the study results, we conclude that the new surface treatment is a safe alternative to the widely used control surface, demonstrating similar osseointegrative properties and time-dependent bone level changes. Further research may explore the broader implications of these findings. TRIAL REGISTRATION: The study is registered on clinicaltrials.gov under the identifier ID: NCT06034171.


Subject(s)
Dental Implants , Mouth, Edentulous , Humans , Dental Implantation, Endosseous/methods , Quality of Life , Osseointegration , Treatment Outcome , Dental Prosthesis, Implant-Supported/methods , Dental Prosthesis Design
9.
Medicina (Kaunas) ; 60(4)2024 Mar 31.
Article in English | MEDLINE | ID: mdl-38674234

ABSTRACT

Background and Objectives: Despite the identified benefits of early implant loading, studies have questioned its advantages compared to delayed loading in edentulous patients. This study aimed to evaluate clinical peri-implant parameters and marginal bone loss around early placed and loaded mandibular implant overdentures with a 60-month follow-up. Materials and Methods: In this prospective cohort study, 43 patients were enrolled to receive 86 early loading sub-crestal dental implants through prosthetic guides. Implant overdentures were supported by two isolated implant locator attachments between two mental foramens. Clinical peri-implant parameters, including plaque index (PI), bleeding index (BI), peri-implant pocket depth (PIPD), and marginal bone loss (MBL) were evaluated using standardized techniques at 1, 12, 24, 36, 48, and 60 months follow-up. At 60 months, complications associated with implant overdentures (IOD's) were noted. The mean comparison of peri-implant clinical parameters was performed through ANOVA test. A p-value of ≤0.05 was taken as significant. Results: Out of the total 43 enrolled patients, 8 patients were lost during follow-up; as a result, 35 patients completed the 5 years follow-up. The mean values of PI, BI, and PIPD increased with no statistical difference (p > 0.05). For marginal bone loss, an increase in the mean values was noted at different time intervals with statistical differences (p < 0.001). The most common complications noted were loosening of the abutment, occlusal adjustment, retentive locator loosening and replacement, and relining of the denture. Conclusions: Early placement of IODs failed to prevent bone loss over time and was associated with complications, predominantly consisting of abutment loosening, occlusal adjustments, broken retentive locator components, relining, and rebasing.


Subject(s)
Alveolar Bone Loss , Denture, Overlay , Mandible , Humans , Female , Male , Prospective Studies , Alveolar Bone Loss/etiology , Middle Aged , Follow-Up Studies , Mandible/surgery , Aged , Dental Prosthesis, Implant-Supported/methods , Dental Prosthesis, Implant-Supported/adverse effects , Dental Implants/adverse effects , Cohort Studies , Adult
10.
Evid Based Dent ; 25(2): 71-72, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38570647

ABSTRACT

DESIGN: This study was an extension of a randomized crossover clinical trial approved by the institutional ethics committee (approval number: D2014-148) and adhered to the CONSORT guidelines. The original study juxtaposed patient contentment with single-implant overdentures (1-IODs) against conventional complete dentures (CCDs), with patient satisfaction being the primary focus. In this follow-up study, the cognitive function of edentulous patients receiving 1-IODs was assessed, specifically monitoring for the emergence of mild cognitive impairment (MCI) throughout a three-year period. Patient outcomes were systematically recorded at predetermined intervals: initially, two months post-1-IOD placement, after one year (with groups alternated between denture types at eight-month marks), then after two and three years. A prosthodontist with a decade of expertise performed all denture-related procedures. This follow-up emphasized the cognitive outcomes using the Montreal Cognitive Assessment (MoCA-J), considering it alongside previously documented results on masticatory function, bone resorption, survival rates, and patient-reported outcomes. CASE SELECTION: Between 2015 and 2016, a follow-up study enrolled edentulous patients over 50 years of age who were proficient in Japanese, had sufficient mandibular bone for implants, and were free of systemic health issues and habits that could impact oral health. The participants were randomly divided into two groups after receiving a central mandibular implant. Group 1 initially used 1-IODs, and Group 2 used unloaded CCDs. After two months and subsequent periods, they swapped denture types. Eventually, all patients chose 1-IODs for continued use. Implant success was monitored over three years. The design featured block randomization and accounted for a sample size of 22, determined to be sufficient for evaluating the primary outcome of patient satisfaction. All patients underwent careful allocation and received customized dental interventions, with detailed radiographic planning and surgical precision guiding the implantation process. DATA ANALYSIS: Multivariable linear mixed models were used to assess within-group changes in both overall and specific cognitive function scores across five timepoints. Age, assessment interval, and upper jaw denture status were incorporated as consistent variables, while individual participants were considered variable elements in the analysis. SPSS software version 22.0 was utilized to conduct the statistical tests, and a p value threshold of 0.05 was predetermined to establish statistical significance. RESULTS: Twenty-two patients with edentulous mandibles received 1-IODs. Memory and executive functions saw significant score increases at multiple timepoints over the three-year period, with statistical significance. Though one participant dropped out and another passed away, and two did not complete the 3-year follow-up, the remaining 18 participants provided comprehensive data. Age and type of maxillary denture were significant factors, influencing MoCA-J scores with older participants and those with fixed dentures showing lower scores in certain domains. Overall, the findings illustrated the positive correlation between 1-IODs and cognitive function in older adults. CONCLUSIONS: Older adults with no natural teeth left in their mandible showed improved cognitive function after one and three years of using 1-IODs, as reflected by their total and specific cognitive domain scores. The study suggests that such implant therapy may offer protective benefits against cognitive decline, demonstrating clinical relevance for patient care, regardless of the maxillary arch (antagonist) condition.


Subject(s)
Cognition , Denture, Overlay , Humans , Aged , Female , Male , Dental Prosthesis, Implant-Supported/methods , Cross-Over Studies , Cognitive Dysfunction , Aged, 80 and over , Patient Satisfaction , Middle Aged , Follow-Up Studies , Mouth, Edentulous
11.
Rev. ADM ; 81(2): 117-122, mar.-abr. 2024. ilus, tab
Article in Spanish | LILACS | ID: biblio-1562752

ABSTRACT

La microtia es un padecimiento congénito de etiología desconocida que se puede presentar asociado a síndromes, su frecuencia es mayor en hombres, tiene predilección por el oído derecho. Se han propuesto distintas alternativas de tratamiento tanto estéticas como funcionales que disminuyan riesgos y aumenten la calidad de vida de los pacientes. Entre los tratamientos más comunes se encuentra el injerto costocondral, siendo una alternativa viable, aunque de mayor riesgo y que puede necesitar varios procedimientos quirúrgicos con el fin de lograr el mejor resultado estético; por lo mismo, uno de los tratamientos más realizados actualmente, es la reconstrucción auricular con implantes osteointegrados que se colocan en la región mastoidea y soportan una prótesis auricular. Se presenta el caso de un paciente masculino quien fue rehabilitado con implantes mastoideos ostoeintegrados para reconstrucción auricular implantosoportada. Las prótesis implantosoportadas reducen la necesidad de realizar cirugías correctivas y posibilitan la buena higiene de la prótesis al ser ésta removible, pero sin sacrificar su estabilidad. Los sistemas más utilizados son los mismos que se emplean en sobredentaduras, ya que el diseño del aditamento transmucoso, se adapta perfectamente al grosor del epitelio en la región mastoidea, por lo que es una excelente alternativa de tratamiento (AU)


Microtia is a congenital condition of unknown etiology that can occur associated with syndromes. Its frequency is greater in men and has a predilection for the right ear. Different treatment alternatives, both aesthetic and functional, have been proposed that reduce risks and increase the quality of life of patients. Among the most common treatments can be found the costochondral graft being a good alternative although greater risk of failure and the probability of several surgeries to get the best aesthetic result. Because of that one of the most used treatments is the placement of osseointegrated implants that can hold a prosthetic ear. Here is a case of a male patient who was rehabilitated with osseointegrated mastoid implants for ear reconstruction. Implant-supported prostheses significantly reduce the number of surgeries that must be performed and is a good option to maintain excellent hygiene as the prosthetic ear is removable, without compromising stability. The most common system is the same as those used in overdentures since the design of the transmucosal attachment fits perfectly to the thickness of epithelium in mastoid region (AU)


Subject(s)
Humans , Male , Adult , Dental Prosthesis, Implant-Supported/methods , Ear Auricle/surgery , Congenital Microtia/rehabilitation , Plastic Surgery Procedures/methods , Ear Auricle/abnormalities
12.
Rev. Odontol. Araçatuba (Impr.) ; 45(1): 9-15, jan.-abr. 2024.
Article in Portuguese | LILACS, BBO - Dentistry | ID: biblio-1553247

ABSTRACT

A evolução dos tratamentos em implantodontia possibilitou uma mudança nos tratamentos reabilitadores para pacientes edêntulos, tornando possível a colocação de próteses fixas, que proporcionam maior qualidade de vida para estes pacientes. Para que estas próteses tenham bom desempenho e longevidade satisfatórios é essencial que se mantenha um padrão adequado de higienização bucal e manutenção profissional. Assim, o objetivo deste trabalho foi realizar uma revisão de literatura a respeito dos principais recursos disponíveis para higienização e manutenção das próteses totais fixas sobre implante (protocolo de Branemark), tanto nos cuidados domiciliares dos pacientes quanto no atendimento profissional do cirurgião dentista. Foi realizada uma busca eletrônica, não sistemática, nas bases de dados Lilacs, Pubmed/Medline, Scielo e ScienceDirect, cruzando-se os seguintes descritores: "Higiene Oral"; "Implantes Dentários"; "Implantação Dentária"; "Manutenção"; "Prótese Dentária Fixada por Implante" e "Prótese Dentária". Foram consultados artigos de revisão de literatura, revisão sistemática, meta-análise, estudos clínicos randomizados, além de livros pertinentes ao assunto, publicados no período de 1995 a 2022.Verificou-se na literatura disponível que os principais instrumentos indicados para uso domiciliar são escova dental, fio dental, escova interdental, irrigador oral, dentifrício e enxaguatório. No atendimento profissional em consultório odontológico deve ser dispendida atenção especial às instruções passadas ao paciente e também fazer o possível para motivar e encorajar o seu engajamento na rotina de higienização, além do acompanhamento periodontal, possíveis substituições de parafusos e instalação de placa oclusal estabilizadora, quando necessário. Manter uma higiene oral adequada é essencial para o sucesso das próteses fixas sobre implantes e o cirurgião dentista desempenha um papel crucial não apenas ao realizar o acompanhamento periódico do paciente, mas também ao sugerir os instrumentos mais apropriados, instruir sobre a higiene oral adequada e motivar o paciente a manter a saúde bucal satisfatória(AU)


The evolution of treatments in implantology has enable a change in rehabilitation treatments for edentulous patients, making it possible to place fixed prostheses that provide a better quality of life for these patients. In order to ensure good performance and satisfactory longevity, it is essential to maintain an appropriate standard of oral hygiene and professional maintenance. Thus, the objective of this work was to conduct a literature review on the main resources available for cleaning and maintenance of complete fixed prostheses on implants (Branemark protocol), both in the patients' home care and in the professional care provided by the dentist. A nonsystematic electronic search was carried out in the Lilacs, Pubmed/Medline, Scielo, and ScienceDirect databases, crossing the following descriptors: "Oral Hygiene"; "Dental Implants"; "Dental Implantation"; "Maintenance"; "Dental Prosthesis, ImplantSupported"; and "Prosthodontics". Literature review articles, systematic reviews, meta-analyses, randomized clinical studies, and relevant books on the subject published from 1995 to 2022 were consulted. The literature available indicates that the main instruments recommended for home care are toothbrush, dental floss, interdental brush, oral irrigator, toothpaste, and mouthwash. In the professional dental office, special attention should be given to the instructions given to the patient, as well as to motivate and encourage their engagement in the hygiene routine, in addition to periodontal monitoring, possible screw replacements, and installation of an occlusal splint when necessary. Maintaining adequate oral hygiene is essential for the success of fixed prostheses on implants, and the dentist plays a crucial role, not only in providing periodic patient follow-up, but also in suggesting the most appropriate instruments, instructing on adequate oral hygiene, and motivating the patient to maintain satisfactory oral health(AU)


Subject(s)
Dental Care , Preventive Dentistry , Dental Prosthesis, Implant-Supported/methods , Dentifrices , Dentists , Mouthwashes
13.
Value Health Reg Issues ; 42: 100979, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38340673

ABSTRACT

OBJECTIVES: The most cost-effective option for replacing lost teeth is not evident because there is a dearth of evidence-based information on implant-supported single crowns versus tooth-supported fixed dental prostheses. This study conducted the analysis of cost-effectiveness of implant-supported single crown and tooth-supported fixed dental prostheses from a social perspective in Türkiye. METHODS: Costs were calculated in the analysis from a social perspective for 2021. Costs and quality-adjusted prosthesis year (QAPY) values were computed over a 20-year period in the study using the Markov model. The computed values were discounted by 5%. The results are presented as the incremental cost-effectiveness ratio. To assess the impact of uncertainty on cost-effectiveness analyses, a tornado diagram and Monte Carlo simulations were created. RESULTS: Throughout the 20-year time horizon, tooth-supported fixed dental prostheses cost $985.58 cumulatively, whereas implant-supported single crown cost $2161.64 (US $1 = 9.22 ₺ as of 15 October 2021). The calculated incremental cost-effectiveness ratio is 1.333 per QAPY. Compared with the implant-supported single crown tooth-supported fixed dental prostheses, it offers a QAPY of 0.882 over a 20-year period, while costing an additional $1176.06. CONCLUSIONS: These results suggest that the implant-supported single crown provided higher QAPY value but was costlier. When the research's findings are compared with the literature, it becomes clear that Türkiye has lower dental care expenses than most other nations.


Subject(s)
Cost-Benefit Analysis , Crowns , Dental Prosthesis, Implant-Supported , Humans , Cost-Benefit Analysis/methods , Dental Prosthesis, Implant-Supported/economics , Dental Prosthesis, Implant-Supported/methods , Crowns/economics , Denture, Partial, Fixed/economics , Quality-Adjusted Life Years , Dental Implants, Single-Tooth/economics , Cost-Effectiveness Analysis
14.
J Esthet Restor Dent ; 36(1): 174-185, 2024 Jan.
Article in English | MEDLINE | ID: mdl-36866726

ABSTRACT

OBJECTIVE: This article highlights a CAD/CAM complete-mouth rehabilitation in an 82-year-old patient by means of a complete maxillary prosthesis and mandibular implant- and tooth-supported fixed restorations made from multilayered zirconia. CLINICAL CONSIDERATIONS: Comprehensive complete-mouth rehabilitations in elderly patients with adaptation of the occlusal vertical dimension (OVD) often present particular challenges. This applies especially when exacting functional and esthetic requirements are to be met and the treatment should not cause the patient too much effort, still ensuring the highest level of quality and efficiency and a low intervention rate. CONCLUSION: The digital approach used for the present patient allowed for an efficient treatment procedure, facilitated virtual evaluations using a face-scan, and enhanced the predictability of the prosthodontic outcome. The approach enabled some steps required in the conventional protocol to be omitted, resulting in a straightforward clinical treatment with minimal strain on the patient. CLINICAL SIGNIFICANCE: Because of the comprehensive recording of extraoral and intraoral data, for example with a facial scanner, it was possible to transfer a digital replica of the patient to the dental laboratory technician. With this protocol, many steps can be performed in the absence of the real patient.


Subject(s)
Dental Prosthesis, Implant-Supported , Mouth Rehabilitation , Aged, 80 and over , Humans , Computer-Aided Design , Dental Prosthesis Design/methods , Dental Prosthesis, Implant-Supported/methods , Denture, Complete , Zirconium
15.
J Esthet Restor Dent ; 36(1): 186-196, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37792734

ABSTRACT

OBJECTIVE: Complete arch implant rehabilitation necessitates meticulous treatment planning and high-level collaboration between surgical and prosthetic dental teams. Emerging virtual technologies hold considerable promise in streamlining this process. The aim of this article is to extend recommendations to clinicians venturing into the virtual patient-assisted esthetic implant rehabilitation workflow. OVERVIEW: This article summarizes recommendations for virtual patient-assisted esthetic implant rehabilitation in the following five aspects: three-dimensional data handling and superimposition, occlusion and virtual articulator integration in creating virtual patients, streamlined face- and prosthetic-driven surgical planning, reuse of presurgical data ("Copy & Paste"), and final impression for passive fitting of final restoration. To illustrate these principles, a case with complete-mouth implant rehabilitation completed within six visits using this virtual patient workflow is presented. CONCLUSION: The virtual patient workflow serves as an invaluable tool to perform treatment planning, enhance efficiency, and ensure predictable outcomes in esthetic complete arch implant rehabilitation. CLINICAL SIGNIFICANCE: Virtual workflows are increasingly prevalent in esthetic implant rehabilitation. Nevertheless, these workflows necessitate a distinct set of knowledge and tools divergent from conventional dentistry practices. This article offers guidelines and recommendations for dental clinicians who are new to this field.


Subject(s)
Computer-Aided Design , Dental Implants , Humans , Dental Prosthesis, Implant-Supported/methods , Esthetics, Dental , Workflow
16.
J Esthet Restor Dent ; 36(4): 566-572, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37882153

ABSTRACT

The reverse impression method involves the extraoral digitalization of the interim implant-supported prostheses and intraoral digitalization of antagonist arch and maxillomandibular relationship. This technique allows the fabrication of implant-supported prostheses by using a complete-digital workflow. The scan analogs make the reverse impression method feasible. However, this method may not be recommended if the interim polymethyl methacrylate prosthesis does not have passive fit. The present manuscript describes an altered reverse impression technique that involves the extraoral digitalization of a conventional verification jig, which has attached scan analogs. With this technique modification, the implant positions captured using the verification jig are used to obtain the virtual definitive implant cast and fabricate the definitive implant-supported prosthesis.


Subject(s)
Dental Implants , Workflow , Dental Impression Technique , Dental Prosthesis, Implant-Supported/methods , Computer-Aided Design
17.
J Oral Maxillofac Surg ; 82(1): 65-72, 2024 01.
Article in English | MEDLINE | ID: mdl-37832597

ABSTRACT

PURPOSE: The purpose of this article is to provide clinicians with options to restore the adult patient with an impacted maxillary canine using dental implants. Literature was reviewed to provide evidence for the methods suggested. METHODS: The search strategy utilized pubmed.gov to identify articles pertinent to identified treatment options. The search used terms which included dental implants and impacted tooth, tilted implants and fixed partial prostheses, 6 mm dental implants, and 4 mm dental implants. Articles were included if they reported dental implant procedures associated with impacted canines in adults, or if they reported on the use of tilted implants, immediate implant placement at time of canine removal, or the use of short implants. Articles with less than 12 months follow up were excluded. RESULTS: The search identified articles which included dental implants and impacted tooth (n = 142), tilted implants and fixed partial (n = 36), 6 mm dental implants (n = 182), and 4 mm dental implants (n = 162). From this search, 28 articles were collated that satisfied the inclusion criteria. The use of tilted implants had success rates ranging from 93% to 99%. Short implants had success rates ranging from 87 to 90% in the posterior maxilla. Immediate implant placement after removal of the impacted canine lacked long term reports. Two cases are included to demonstrate treatment planning using navigation to guide implant placement in an adult patient with an impacted maxillary canine. CONCLUSIONS: The evidence-based literature concerning implant placement associated with adult maxillary canines is limited. There is evidence to support tilting implants to avoid the impacted canine, or the use of short implants splinted together to avoid the impacted tooth. Other options had insufficient data to offer support.


Subject(s)
Dental Implants , Tooth, Impacted , Adult , Humans , Dental Implantation, Endosseous/methods , Tooth, Impacted/surgery , Dental Prosthesis, Implant-Supported/methods , Maxilla/surgery , Treatment Outcome , Dental Prosthesis Design , Follow-Up Studies
18.
J Prosthodont Res ; 68(2): 206-214, 2024 Apr 08.
Article in English | MEDLINE | ID: mdl-37648482

ABSTRACT

PURPOSE: The present study aimed to identify, through a critical review of the literature, the success factors associated with the splinting of fixed prostheses on adjacent implants of the posterior sectors in partially edentulous patients compared with those not splinted. STUDY SELECTION: A MEDLINE strategy was implemented based on a research question to systematically search and extract information from databases (PubMed and Scopus) using MeSH terms/keywords identified for each domain. Systematic reviews, clinical and in vitro studies were selected and classified according to eligibility criteria based on the research question and level of evidence using the PRISMA flowchart. RESULTS: A total of 32 studies were selected for data extraction and analysis according to study design (three systematic reviews, 14 clinical studies, and 15 in vitro studies). Overall, the studies found no significant difference in the association between the survival rate and prosthesis type. In clinical studies, there have been no differences in marginal bone loss between splinted and non-splinted prostheses, and the influence of peri-implant status and restorative materials has been poorly evaluated. The distribution of stress and loads determined in the in vitro studies showed results that could favor splinted prostheses; however, are generally associated with implant design. CONCLUSIONS: The need for splinted or non-splinted adjacent implant-supported prostheses remains controversial. The reviewed evidence indicates that factors such as implant size and its relationship with coronal height could be important in decision-making.


Subject(s)
Dental Implants , Mouth, Edentulous , Humans , Dental Materials , Dental Prosthesis, Implant-Supported/methods , Dental Prosthesis Design
19.
J Prosthodont ; 33(1): 95-101, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37157952

ABSTRACT

Clinically, the proximal surfaces of teeth adjacent to an implant restoration usually need to be adjusted to build a preferable adjacency relationship. However, it is difficult for freehand preparation to get a favorable proximal contour in some cases. In the workflow presented here, virtual grinding can be made to adjacent teeth, under the consideration of functional reconstruction and biological requirements, and then the grinding can be implemented using digital templates and a specialized bur. This allows for more precise and accurate adjustments to be made during the clinical procedure, reducing the risk of over- or under-preparation of the proximal surfaces. In addition, the use of specialized diamond burs and grinding guides can make the procedure more efficient and streamlined, reducing the time required for proximal adjustment and minimizing patient discomfort. The resulting implant-supported prosthesis is more likely to function properly and last longer, as the precise proximal contacts can help distribute occlusal forces more evenly across the dentition. Overall, the use of digital technology for precise adjustment of proximal contacts during implant restorations represents an important advancement in modern dentistry, enabling dentists to provide their patients with more accurate, efficient, and effective dental care.


Subject(s)
Dental Implants , Humans , Workflow , Dental Prosthesis, Implant-Supported/methods , Computers , Diamond , Computer-Aided Design
20.
J Prosthodont Res ; 68(1): 40-49, 2024 Jan 16.
Article in English | MEDLINE | ID: mdl-37211409

ABSTRACT

PURPOSE: This systematic review aimed to evaluate the effects of implant placement sites on the biomechanical behavior of implant-assisted removable partial dentures (IARPDs) using finite element analysis (FEA). STUDY SELECTION: Two reviewers independently conducted manual searches of the PubMed, Scopus, and ProQuest databases for articles investigating implant location in IARPDs using FEA, according to the 2020 Systematic Reviews and Meta-analyses statement. Studies published in English up to August 1, 2022, were included in the analysis based on the critical question. RESULTS: Seven articles meeting the inclusion criteria were systematically reviewed. Six studies investigated mandibular Kennedy Class I and one study investigated mandibular Kennedy Class II. Implant placement reduced the displacement and stress distribution of the IARPD components, including dental implants and abutment teeth, regardless of the Kennedy Class type and dental implant placement site. Most of the included studies showed that, based on the biomechanical behavior, the molar region, rather than the premolar region, is the preferred implant placement site. None of the selected studies investigated the maxillary Kennedy Class I and II. CONCLUSIONS: Based on the FEA regarding mandibular IARPDs, we concluded that implant placement in both the premolar and molar regions improves the biomechanical behaviors of IARPD components, regardless of the Kennedy Class. Implant placement in the molar region results in more suitable biomechanical behaviors compared with implant placement in the premolar region in Kennedy Class I. No conclusion was reached for Kennedy Class II due to the lack of relevant studies.


Subject(s)
Dental Prosthesis, Implant-Supported , Denture, Partial, Removable , Dental Implants , Dental Prosthesis, Implant-Supported/methods , Finite Element Analysis , Mandible , Humans
SELECTION OF CITATIONS
SEARCH DETAIL