Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 2.674
1.
Sci Robot ; 9(91): eadk3925, 2024 Jun 12.
Article En | MEDLINE | ID: mdl-38865475

Electrotactile stimulus is a form of sensory substitution in which an electrical signal is perceived as a mechanical sensation. The electrotactile effect could, in principle, recapitulate a range of tactile experience by selective activation of nerve endings. However, the method has been plagued by inconsistency, galvanic reactions, pain and desensitization, and unwanted stimulation of nontactile nerves. Here, we describe how a soft conductive block copolymer, a stretchable layout, and concentric electrodes, along with psychophysical thresholding, can circumvent these shortcomings. These purpose-designed materials, device layouts, and calibration techniques make it possible to generate accurate and reproducible sensations across a cohort of 10 human participants and to do so at ultralow currents (≥6 microamperes) without pain or desensitization. This material, form factor, and psychophysical approach could be useful for haptic devices and as a tool for activation of the peripheral nervous system.


Elastomers , Electric Conductivity , Psychophysics , Touch , Humans , Touch/physiology , Adult , Female , Male , Equipment Design , Electric Stimulation , Young Adult , Polymers , Electrodes , Calibration , Touch Perception/physiology
2.
Prog Orthod ; 25(1): 24, 2024 Jun 17.
Article En | MEDLINE | ID: mdl-38880839

INTRODUCTION: Metallic and elastomeric ligatures are widely used in orthodontics to secure the archwire within the bracket slots, but elastomeric ligatures have traditionally been associated with increased microbial colonization, which could adversely affect periodontal health. AIM: This systematic review compares the periodontal effects of elastomeric and steel ligatures used for orthodontic fixed appliances. METHODS: Unrestricted literature search of 7 databases (MEDLINE, Scopus, Web of Science, Embase, Cochrane Database of Systematic Reviews, Cochrane Central Register of Controlled Trials, and Virtual Health Library) up to July 2023 were performed for randomized / non-randomized clinical studies on humans comparing the two ligation methods during fixed-appliance therapy. After duplicate study selection, data extraction, and risk-of-bias assessment with the Risk of Bias (RoB) 2 or the Risk Of Bias In Non-randomized Studies - of Interventions (ROBINS-I) tool, random-effects meta-analyses of Mean Differences (MD) or Standardized Mean Differences (SMD) and their 95% confidence intervals (CIs) were carried out, followed by assessment of certainty of existing evidence with the Grades of Recommendation, Assessment, Development, and Evaluation (GRADE) approach. RESULTS: A total of 11 studies (3 randomized / 8 non-randomized) with 354 patients (mean age 14.7 years and 42% male) were included. No statistically significant differences were seen for plaque index (5 studies; SMD = 0.48; 95% CI = -0.03 to 1.00; P = 0.07), gingival index (2 studies; MD = 0.01; 95% CI = -0.14 to 0.16; P = 0.89), probing pocket depth (2 studies; MD = 0; 95% CI = -0.17 to 0.16; P = 0.97), or Streptococcus mutans counts (4 studies; SMD = 0.40; 95% CI=-0.41 to 1.20; P = 0.21). Elastomeric ligatures were associated with moderately increased total bacterial load (3 studies; SMD = 0.43; 95% CI = 0.10 to 0.76; P = 0.03). Confidence in these estimates was low in all instances due to the inclusion of non-randomized studies with high risk of bias. CONCLUSIONS: Existing low quality evidence indicates that ligature method does not seem to influence the periodontal health during fixed treatment, even if elastomeric ligatures are associated with a moderate increase of bacterial load. REGISTRATION: PROSPERO (CRD42023444383).


Elastomers , Orthodontic Appliances, Fixed , Humans , Steel , Periodontal Index , Orthodontic Brackets , Ligation
3.
Int J Biol Macromol ; 271(Pt 2): 132766, 2024 Jun.
Article En | MEDLINE | ID: mdl-38823742

The efficient development and utilization of green biomass-based macromolecule engineering materials are essential for the sustainable development of human civilization. In this study, lignin-based ethylene-propylene-diene-monomer (EPDM) composites with excellent mechanical performance were fabricated using a simple method. The effects of water-insoluble enzymatically hydrolyzed lignin (EL) and alkali lignin (KL) on the mechanical performance of the composites were investigated separately. The results showed that the tensile strength of EPDM reinforced with KL and EL increased to 24.5 MPa and 22.1 MPa, respectively, surpassing that of the carbon black (CB)-reinforced EPDM. After 72 h of thermo-oxidative aging, the retention rates of the tensile strength and elongation at break in the lignin-reinforced EPDM were much better than those formed with pure CB, indicating that lignin significantly improved the thermo-oxidative aging resistance of the composites. In summary, the Zn2+ coordination bonds formed between the interface of EPDM and lignin in lignin/CB/EPDM ternary composites effectively improved the mechanical performance and aging resistance of the composites. This study has significant implications for enhancing the utilization of lignin and green functional polymer materials.


Lignin , Lignin/chemistry , Tensile Strength , Ethylenes/chemistry , Structure-Activity Relationship , Zinc/chemistry , Oxidation-Reduction , Cross-Linking Reagents/chemistry , Elastomers
4.
BMC Oral Health ; 24(1): 713, 2024 Jun 20.
Article En | MEDLINE | ID: mdl-38902666

BACKGROUND: Low mechanical properties are the main limitation of glass ionomer cements (GICs). The incorporation of elastomeric micelles is expected to enhance the strength of GICs without detrimentally affecting their physical properties and biocompatibility. This study compared the chemical and mechanical properties, as well as the cytotoxicity, of elastomeric micelles-containing glass ionomer cement (DeltaFil, DT) with commonly used materials, including EQUIA Forte Fil (EF), Fuji IX GP Extra (F9), and Ketac Molar (KT). METHOD: Powder particles of GICs were examined with SEM-EDX. Setting kinetics were assessed using ATR-FTIR. Biaxial flexural strength/modulus and Vickers surface microhardness were measured after immersion in water for 24 h and 4 weeks. The release of F, Al, Sr, and P in water over 8 weeks was analyzed using a fluoride-specific electrode and ICP-OES. The toxicity of the material extract on mouse fibroblasts was also evaluated. RESULTS: High fluoride levels in the powder were detected with EF and F9. DT demonstrated an initial delay followed by a faster acid reaction compared to other cements, suggesting an improved snap set. DT also exhibited superior flexural strength than other materials at both 24 h and 4 weeks but lower surface microhardness (p < 0.05). EF and F9 showed higher release of F, Al, and P than DT and KT. There was no statistically significant difference in fibroblast viability among the tested materials (p > 0.05). CONCLUSIONS: Elastomeric micelles-containing glass ionomer cement (DT) exhibited satisfactory mechanical properties and cytocompatibility compared with other materials. DT could, therefore, potentially be considered an alternative high-strength GIC for load-bearing restorations.


Elastomers , Fibroblasts , Flexural Strength , Glass Ionomer Cements , Hardness , Materials Testing , Micelles , Glass Ionomer Cements/toxicity , Glass Ionomer Cements/chemistry , Animals , Mice , Fibroblasts/drug effects , Elastomers/chemistry , Elastomers/toxicity , Aluminum/chemistry , Fluorides/chemistry , Strontium/chemistry , Polycarboxylate Cement/chemistry , Polycarboxylate Cement/toxicity , Cell Survival/drug effects , Microscopy, Electron, Scanning , Surface Properties , Pliability , Kinetics , Spectroscopy, Fourier Transform Infrared , Stress, Mechanical , Time Factors , Biocompatible Materials/chemistry
5.
ACS Appl Bio Mater ; 7(6): 3777-3785, 2024 Jun 17.
Article En | MEDLINE | ID: mdl-38754861

Oral devices, such as foil-type devices, show great potential for the delivery of poorly permeable macromolecules by enabling unidirectional release of the loaded pharmaceutical composition in close proximity to the epithelium in the small intestine or colon. However, one of the primary concerns associated with the use of foil-type devices so far has been the utilization of nonbiodegradable elastomers in the fabrication of the devices. Therefore, research into biodegradable substitute materials with similar characteristics enables drug delivery in a sustainable and environmentally friendly manner. In this study, a biodegradable elastomer, polyoctanediol citrate (POC), was synthesized via a one-pot reaction, with subsequent purification and microscale pattern replication via casting. The microstructure geometry was designed to enable fabrication of foil-type devices with the selected elastomer, which has a high intrinsic surface free energy. The final elastomer was demonstrated to have an elastic modulus ranging up to 2.2 ± 0.1 MPa, with strain at failure up to 110.1 ± 1.5%. Devices were loaded with acetaminophen and enterically coated, demonstrating 100% release at 2.5 h, following dissolution for 1 h in 0.1 M hydrochloric acid and 1.5 h in pH 6.8 phosphate-buffered saline. The elastomer demonstrated promising properties based on mechanical testing, surface free energy evaluation, and degradation studies.


Biocompatible Materials , Elastomers , Materials Testing , Particle Size , Elastomers/chemistry , Biocompatible Materials/chemistry , Biocompatible Materials/chemical synthesis , Drug Delivery Systems , Humans , Acetaminophen/chemistry , Acetaminophen/administration & dosage , Administration, Oral , Citrates/chemistry , Macromolecular Substances/chemistry , Macromolecular Substances/chemical synthesis , Polymers/chemistry
6.
J Mech Behav Biomed Mater ; 155: 106566, 2024 Jul.
Article En | MEDLINE | ID: mdl-38729087

The objective of this study is to develop a reliable tribological model to enable a more thorough investigation of the frictional behavior of fascia tissues connected to non-specific lower back pain. Several models were designed and evaluated based on their coefficient of friction, using a low-frequency, low-load reciprocating motion. The study found that two technical elastomers, layered on PDMS to simulate the fascia and underlying muscle, are suitable substitutes for biological tissue in the model. The influence of tribopair geometry was also examined, and the results showed that greater conformity of contact leads to a lower COF, regardless of the material combination used. Finally, the friction properties of HA of various molecular weights and concentrations were tested.


Fascia , Friction , Materials Testing , Fascia/physiology , Dimethylpolysiloxanes/chemistry , Biomechanical Phenomena , Models, Biological , Elastomers/chemistry
7.
ACS Appl Mater Interfaces ; 16(19): 25404-25414, 2024 May 15.
Article En | MEDLINE | ID: mdl-38692284

Liquid crystal elastomers (LCEs), as a classical two-way shape-memory material, are good candidates for developing artificial muscles that mimic the contraction, expansion, or rotational behavior of natural muscles. However, biomimicry is currently focused more on the actuation functions of natural muscles dominated by muscle fibers, whereas the tactile sensing functions that are dominated by neuronal receptors and synapses have not been well captured. Very few studies have reported the sensing concept for LCEs, but the signals were still donated by macroscopic actuation, that is, variations in angle or length. Herein, we develop a conductive porous LCE (CPLCE) using a solvent (dimethyl sulfoxide (DMSO))-templated photo-cross-linking strategy, followed by carbon nanotube (CNT) incorporation. The CPLCE has excellent reversible contraction/elongation behavior in a manner similar to the actuation functions of skeletal muscles. Moreover, the CPLCE shows excellent pressure-sensing performance by providing real-time electrical signals and is capable of microtouch sensing, which is very similar to natural tactile sensing. Furthermore, macroscopic actuation and tactile sensation can be integrated into a single system. Proof-of-concept studies reveal that the CPLCE-based artificial muscle is sensitive to external touch while maintaining its excellent actuation performance. The CPLCE with tactile sensation beyond reversible actuation is expected to benefit the development of versatile artificial muscles and intelligent robots.


Elastomers , Liquid Crystals , Nanotubes, Carbon , Liquid Crystals/chemistry , Elastomers/chemistry , Nanotubes, Carbon/chemistry , Porosity , Solvents/chemistry , Touch/physiology , Artificial Organs , Muscle, Skeletal/physiology , Muscle, Skeletal/chemistry , Humans
8.
Int J Biol Macromol ; 268(Pt 2): 131946, 2024 May.
Article En | MEDLINE | ID: mdl-38692545

The development of flexible wearable multifunctional electronics has gained great attention in the field of human motion monitoring. However, developing mechanically tough, highly stretchable, and recyclable composite conductive materials for application in multifunctional sensors remained great challenges. In this work, a mechanically tough, highly stretchable, and recyclable composite conductive elastomer with the dynamic physical-chemical dual-crosslinking network was fabricated by the combination of multiple hydrogen bonds and dynamic ester bonds. To prepare the proposed composite elastomers, the polyaniline-modified carboxylate cellulose nanocrystals (C-CNC@PANI) were used as both conductive filler to yield high conductivity of 15.08 mS/m, and mechanical reinforcement to construct the dynamic dual-crosslinking network with epoxidized natural rubber latex to realize the high mechanical strength (8.65 MPa) and toughness (29.57 MJ/m3). Meanwhile, the construction of dynamic dual-crosslinking network endowed the elastomer with satisfactory recyclability. Based on these features, the composite conductive elastomers were used as strain sensors, and electrode material for assembling flexible and recyclable self-powered sensors for monitoring human motions. Importantly, the composite conductive elastomers maintained reliable sensing and energy harvesting performance even after multiple recycling process. This study provides a new strategy for the preparation of recyclable, mechanically tough composite conductive materials for wearable sensors.


Cellulose , Elastomers , Electric Conductivity , Rubber , Wearable Electronic Devices , Elastomers/chemistry , Cellulose/chemistry , Rubber/chemistry , Humans , Nanocomposites/chemistry , Nanoparticles/chemistry , Mechanical Phenomena , Aniline Compounds/chemistry
9.
ACS Nano ; 18(22): 14558-14568, 2024 Jun 04.
Article En | MEDLINE | ID: mdl-38761154

To propel electronic skin (e-skin) to the next level by integrating artificial intelligence features with advanced sensory capabilities, it is imperative to develop stretchable memory device technology. A stretchable memory device for e-skin must offer, in particular, long-term data storage while ensuring the security of personal information under any type of deformation. However, despite the significance of these needs, technology related to stretchable memory devices remains in its infancy. Here, we report an intrinsically stretchable floating gate (FG) polymer memory transistor. The device features a dual-stimuli (optical and electrical) writing system to prevent easy erasure of recorded data. An FG comprising an intermixture of Ag nanoparticles and elastomer and with proper energy-band alignment between the semiconductor and dielectric facilitated sustainable memory performance, while achieving a high memory on/off ratio (>105) and a long retention time (106 s) with the ability to withstand 50% uniaxial or 30% biaxial strain. In addition, our memory transistor exhibited high mechanical durability over multiple stretching cycles (1000 times), along with excellent environmental stability with respect to factors such as temperature, moisture, air, and delamination. Finally, we fabricated a 7 × 7 active-matrix memory transistor array for personalized storage of e-skin data and successfully demonstrated its functionality.


Transistors, Electronic , Wearable Electronic Devices , Information Storage and Retrieval , Silver/chemistry , Humans , Elastomers/chemistry , Computer Storage Devices , Metal Nanoparticles/chemistry , Equipment Design
10.
Biomaterials ; 309: 122598, 2024 Sep.
Article En | MEDLINE | ID: mdl-38696943

Current vascular grafts, primarily Gore-Tex® and Dacron®, don't integrate with the host and have low patency in small-diameter vessels (<6 mm). Biomaterials that possess appropriate viscoelasticity, compliance, and high biocompatibility are essential for their application in small blood vessels. We have developed metal ion crosslinked poly(propanediol-co-(hydroxyphenyl methylene)amino-propanediol sebacate) (M-PAS), a biodegradable elastomer with a wide range of mechanical properties. We call these materials metallo-elastomers. An initial test on Zn-, Fe-, and Cu-PAS grafts reveals that Cu-PAS is the most suitable because of its excellent elastic recoil and well-balanced polymer degradation/tissue regeneration rate. Here we report host remodeling of Cu-PAS vascular grafts in rats over one year. 76 % of the grafts remain patent and >90 % of the synthetic polymer is degraded by 12 months. Extensive cell infiltration leads to a positive host remodeling. The remodeled grafts feature a fully endothelialized lumen. Circumferentially organized smooth muscle cells, elastin fibers, and widespread mature collagen give the neoarteries mechanical properties similar to native arteries. Proteomic analysis further reveals the presence of important vascular proteins in the neoarteries. Evidence suggests that Cu-PAS is a promising material for engineering small blood vessels.


Blood Vessel Prosthesis , Carotid Arteries , Elastomers , Animals , Elastomers/chemistry , Rats , Male , Biocompatible Materials/chemistry , Rats, Sprague-Dawley , Polymers/chemistry , Materials Testing
11.
ACS Appl Mater Interfaces ; 16(15): 19480-19495, 2024 Apr 17.
Article En | MEDLINE | ID: mdl-38581369

Light-driven soft actuators based on photoresponsive materials can be used to mimic biological motion, such as hand movements, without involving rigid or bulky electromechanical actuations. However, to our knowledge, no robust photoresponsive material with desireable mechanical and biological properties and relatively simple manufacture exists for robotics and biomedical applications. Herein, we report a new visible-light-responsive thermoplastic elastomer synthesized by introducing photoswitchable moieties (i.e., azobenzene derivatives) into the main chain of poly(ε-caprolactone) based polyurethane urea (PAzo). A PAzo elastomer exhibits controllable light-driven stiffness softening due to its unique nanophase structure in response to light, while possessing excellent hyperelasticity (stretchability of 575.2%, elastic modulus of 17.6 MPa, and strength of 44.0 MPa). A bilayer actuator consisting of PAzo and polyimide films is developed, demonstrating tunable bending modes by varying incident light intensities. Actuation mechanism via photothermal and photochemical coupling effects of a soft-hard nanophase is demonstrated through both experimental and theoretical analyses. We demonstrate an exemplar application of visible-light-controlled soft "fingers" playing a piano on a smartphone. The robustness of the PAzo elastomer and its scalability, in addition to its excellent biocompatibility, opens the door to the development of reproducible light-driven wearable/implantable actuators and lightweight soft robots for clinical applications.


Elastomers , Robotics , Elastomers/chemistry , Polyurethanes , Urea
12.
Biomed Mater ; 19(3)2024 Apr 30.
Article En | MEDLINE | ID: mdl-38636492

Three-dimensional (3D) printing has emerged as a transformative technology for tissue engineering, enabling the production of structures that closely emulate the intricate architecture and mechanical properties of native biological tissues. However, the fabrication of complex microstructures with high accuracy using biocompatible, degradable thermoplastic elastomers poses significant technical obstacles. This is primarily due to the inherent soft-matter nature of such materials, which complicates real-time control of micro-squeezing, resulting in low fidelity or even failure. In this study, we employ Poly (L-lactide-co-ϵ-caprolactone) (PLCL) as a model material and introduce a novel framework for high-precision 3D printing based on the material plasticization process. This approach significantly enhances the dynamic responsiveness of the start-stop transition during printing, thereby reducing harmful errors by up to 93%. Leveraging this enhanced material, we have efficiently fabricated arrays of multi-branched vascular scaffolds that exhibit exceptional morphological fidelity and possess elastic moduli that faithfully approximate the physiological modulus spectrum of native blood vessels, ranging from 2.5 to 45 MPa. The methodology we propose for the compatibilization and modification of elastomeric materials addresses the challenge of real-time precision control, representing a significant advancement in the domain of melt polymer 3D printing. This innovation holds considerable promise for the creation of detailed multi-branch vascular scaffolds and other sophisticated organotypic structures critical to advancing tissue engineering and regenerative medicine.


Biocompatible Materials , Elastomers , Polyesters , Printing, Three-Dimensional , Tissue Engineering , Tissue Scaffolds , Elastomers/chemistry , Tissue Scaffolds/chemistry , Tissue Engineering/methods , Polyesters/chemistry , Biocompatible Materials/chemistry , Elastic Modulus , Materials Testing , Humans , Stress, Mechanical , Blood Vessels , Blood Vessel Prosthesis
13.
ACS Sens ; 9(4): 2156-2165, 2024 04 26.
Article En | MEDLINE | ID: mdl-38629405

Anisotropic strain sensors capable of multidirectional sensing are crucial for advanced sensor applications in human motion detection. However, current anisotropic sensors encounter challenges in achieving a balance among high sensitivity, substantial stretchability, and a wide linear detection range. To address these challenges, a facile freeze-casting strategy was employed to construct oriented filler networks composed of carbon nanotubes and conductive carbon black within a brominated butyl rubber ionomer (iBIIR) matrix. The resulting anisotropic sensor based on the iBIIR composites exhibited distinct gauge factors (GF) in the parallel and vertical directions (GF∥ = 4.91, while GF⊥ = 2.24) and a broad linear detection range over a strain range of 190%. This feature enables the sensor to detect various human activities, including uniaxial pulse, finder bending, elbow bending, and cervical spine movements. Moreover, the ion-cross-linking network within the iBIIR, coupled with strong π-cation interactions between the fillers and iBIIR macromolecules, imparted high strength (12.3 MPa, nearly twice that of pure iBIIR) and an ultrahigh elongation at break (>1800%) to the composites. Furthermore, the sensor exhibited exceptional antibacterial effectiveness, surpassing 99% against both Escherichia coli and Staphylococcus aureus. Notably, the sensor was capable of wireless sensing. It is anticipated that anisotropic sensors will have extensive application prospects in flexible wearable devices.


Elastomers , Nanotubes, Carbon , Wireless Technology , Humans , Elastomers/chemistry , Nanotubes, Carbon/chemistry , Anisotropy , Wearable Electronic Devices , Soot/chemistry , Movement , Staphylococcus aureus/isolation & purification
14.
Sci Rep ; 14(1): 7172, 2024 03 26.
Article En | MEDLINE | ID: mdl-38531891

To address the concern that biodegradable elastomers are environmental-friendly but usually associated with poor properties for practical utilization, we report a star-crosslinked poly(ethylene glycol-glycerol-itaconate-sebacate) (PEGIS) elastomer synthesized by esterification, polycondensation and UV curing, and reinforced by bacterial cellulose (BC). The interpenetrating network of primary BC backbone and vulcanized elastomer is achieved by the "in-situ secondary network construction" strategy. With the well dispersion of BC without agglomeration, the mechanical properties of PEGIS are significantly enhanced in tensile strength, Young's modulus and elongation at break. The reinforcement strategy is demonstrated to be efficient and offers a route to the development of biodegradable elastomers for a variety of applications in the future.


Cellulose , Decanoates , Elastomers , Glycerol/analogs & derivatives , Polymers , Succinates , Ethylene Glycol , Materials Testing
15.
Biosens Bioelectron ; 254: 116222, 2024 Jun 15.
Article En | MEDLINE | ID: mdl-38518560

Materials that have the ability to manipulate shapes in response to stimuli such as heat, light, humidity and magnetism offer a means for versatile, sophisticated functions in soft robotics or biomedical implants, while such a reactive transformation has certain drawbacks including high operating temperatures, inherent rigidity and biological hazard. Herein, we introduce biodegradable, self-adhesive, shape-transformable poly (L-lactide-co-ε-caprolactone) (BSS-PLCL) that can be triggered via thermal stimulation near physiological temperature (∼38 °C). Chemical inspections confirm the fundamental properties of the synthetic materials in diverse aspects, and study on mechanical and biochemical characteristics validates exceptional stretchability up to 800 % and tunable dissolution behaviors under biological conditions. The integration of the functional polymer with a bioresorbable electronic system highlights potential for a wide range of biomedical applications.


Biosensing Techniques , Elastomers , Elastomers/chemistry , Biocompatible Materials/chemistry , Absorbable Implants , Polymers/chemistry , Polyesters/chemistry
16.
Sensors (Basel) ; 24(5)2024 Mar 05.
Article En | MEDLINE | ID: mdl-38475217

Age-related vessel deterioration leads to changes in the structure and function of the heart and blood vessels, notably stiffening of vessel walls, increasing the risk of developing cardiovascular disease (CVD), which accounts for 17.9 million global deaths annually. This study describes the fabrication of custom-made silicon vessels with varying mechanical properties (arterial stiffness). The primary objective of this study was to explore how changes in silicone formulations influenced vessel properties and their correlation with features extracted from signals obtained from photoplethysmography (PPG) reflectance sensors in an in vitro setting. Through alterations in the silicone formulations, it was found that it is possible to create elastomers exhibiting an elasticity range of 0.2 MPa to 1.22 MPa. It was observed that altering vessel elasticity significantly impacted PPG signal morphology, particularly reducing amplitude with increasing vessel stiffness (p < 0.001). A p-value of 5.176 × 10-15 and 1.831 × 10-14 was reported in the red and infrared signals, respectively. It has been concluded in this study that a femoral artery can be recreated using the silicone material, with the addition of a softener to achieve the required mechanical properties. This research lays the foundation for future studies to replicate healthy and unhealthy vascular systems. Additional pathologies can be introduced by carefully adjusting the elastomer materials or incorporating geometrical features consistent with various CVDs.


Cardiovascular Diseases , Vascular Stiffness , Humans , Photoplethysmography , Silicones , Arteries , Elastomers
17.
Chem Soc Rev ; 53(8): 4086-4153, 2024 Apr 22.
Article En | MEDLINE | ID: mdl-38465517

Degradable biomedical elastomers (DBE), characterized by controlled biodegradability, excellent biocompatibility, tailored elasticity, and favorable network design and processability, have become indispensable in tissue repair. This review critically examines the recent advances of biodegradable elastomers for tissue repair, focusing mainly on degradation mechanisms and evaluation, synthesis and crosslinking methods, microstructure design, processing techniques, and tissue repair applications. The review explores the material composition and cross-linking methods of elastomers used in tissue repair, addressing chemistry-related challenges and structural design considerations. In addition, this review focuses on the processing methods of two- and three-dimensional structures of elastomers, and systematically discusses the contribution of processing methods such as solvent casting, electrostatic spinning, and three-/four-dimensional printing of DBE. Furthermore, we describe recent advances in tissue repair using DBE, and include advances achieved in regenerating different tissues, including nerves, tendons, muscle, cardiac, and bone, highlighting their efficacy and versatility. The review concludes by discussing the current challenges in material selection, biodegradation, bioactivation, and manufacturing in tissue repair, and suggests future research directions. This concise yet comprehensive analysis aims to provide valuable insights and technical guidance for advances in DBE for tissue engineering.


Biocompatible Materials , Elastomers , Regenerative Medicine , Tissue Engineering , Humans , Elastomers/chemistry , Biocompatible Materials/chemistry , Animals
18.
Environ Pollut ; 347: 123652, 2024 Apr 15.
Article En | MEDLINE | ID: mdl-38447657

The widespread use of synthetic turf in sports has raised health concerns due to potential risks from nanoplastic inhalation or ingestion. Our research focused on detecting nanoplastics in drainage water from a synthetic football field and evaluating the toxicity of these materials after mechanical fragmentation. We collected and analysed drainage water samples for polymer content and subjected high-density polyethylene (HDPE) straws and ethylene propylene diene monomer (EPDM) granules used on synthetic football fields, to mechanical breakdown to create nanoplastics. The results indicated the presence of trace amounts of EPDM in the water samples. Furthermore, the toxicological assessment revealed that the broken-down nanoplastics and leachate from the surface of EPDM rubber granules exhibited high toxicity to Daphnia magna, while nanoplastics from the inner material exhibited no significant toxicity. The findings highlight the urgent need for future research to identify these specific toxic agents from the surface of EPDM granules.


Microplastics , Soccer , Elastomers , Ethylenes , Water
19.
J Am Chem Soc ; 146(15): 10699-10707, 2024 Apr 17.
Article En | MEDLINE | ID: mdl-38518116

Ultralow temperature-tolerant electronic skins (e-skins) can endow polar robots with tactile feedback for exploring in extremely cold polar environments. However, it remains a challenge to develop e-skins that enable sensitive touch sensation and self-healing at ultralow temperatures. Herein, we describe the development of a sensitive robotic hand e-skin that can stretch, self-heal, and sense at temperatures as low as -78 °C. The elastomeric substrate of this e-skin is based on poly(dimethylsiloxane) supramolecular polymers and multistrength dynamic H-bonds, in particular with quadruple H-bonding motifs (UPy). The structure-performance relationship of the elastomer at ultralow temperatures is investigated. The results show that elastomers with side-chain UPy units exhibit higher stretchability (∼3257%) and self-healing efficiency compared to those with main-chain UPy units. This is attributed to the lower binding energy variation and lower potential well. Based on the elastomer with side-chain UPy and man-made electric ink, a sensitive robotic hand e-skin for usage at -78 °C is constructed to precisely sense the shape of objects and specific symbols, and its sensation can completely self-recover after being damaged. The findings of this study contribute to the concept of using robotic hands with e-skins in polar environments that make human involvement limited, dangerous, or impossible.


Elastomers , Wearable Electronic Devices , Humans , Elastomers/chemistry , Elasticity , Skin , Electricity
20.
Bioinspir Biomim ; 19(3)2024 Apr 03.
Article En | MEDLINE | ID: mdl-38467068

Bioinspired and biomimetic soft grippers are rapidly growing fields. They represent an advancement in soft robotics as they emulate the adaptability and flexibility of biological end effectors. A prominent example of a gripping mechanism found in nature is the octopus tentacle, enabling the animal to attach to rough and irregular surfaces. Inspired by the structure and morphology of the tentacles, this study introduces a novel design, fabrication, and characterization method of dielectric elastomer suction cups. To grasp objects, the developed suction cups perform out-of-plane deflections as the suction mechanism. Their attachment mechanism resembles that of their biological counterparts, as they do not require a pre-stretch over a rigid frame or any external hydraulic or pneumatic support to form and hold the dome structure of the suction cups. The realized artificial suction cups demonstrate the capability of generating a negative pressure up to 1.3 kPa in air and grasping and lifting objects with a maximum 58 g weight under an actuation voltage of 6 kV. They also have sensing capabilities to determine whether the grasping was successful without the need of lifting the objects.


Octopodiformes , Robotics , Animals , Biomimetics/methods , Elastomers , Octopodiformes/anatomy & histology , Robotics/methods
...