Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 7.104
Filter
1.
BMC Cardiovasc Disord ; 24(1): 421, 2024 Aug 13.
Article in English | MEDLINE | ID: mdl-39134935

ABSTRACT

BACKGROUND: Idiopathic ventricular arrhythmias (IVAs) arising from different portions of the communicating vein of the left ventricular summit (summit-CV) are not a rare phenomenon. Whereas its electrocardiographic (ECG) and electrophysiological characteristics are not fully investigated. OBJECTIVE: This study aimed to identify distinct ECG and electrophysiological features of IVAs originating from different portions of summit-CV. METHODS: Nineteen patients confirmed arising from summit-CV were included in this study. RESULTS: The 19 patients were divided into proximal and distal portion groups based on their target sites in summit-CV. In the proximal portion group, 100% (11/11) VAs showed dominant negative (rs or QS) waves in lead I, while in the distal portion group, 87.5% (7/8) showed dominant positive waves (R, Rs or r) (p < 0.000). In lead V1, 100% (11/11) of the proximal portion group showed dominant positive waves (R or Rs), while 62.50% (5/8) of the distal portion group showed positive and negative bidirectional or negative waves (RS or rS) (p < 0.005). RI>4mV, SI<3.5mV, RV1<13mV, SV1>3.5mV, RI/SI>0.83, and RV1/SV1< 2.6 indicated a distal portion of summit-CV with the predictive value of 0.909, 1.000, 0.653, 0.972, 0.903, 0.966, respectively. A more positive wave in lead I and a more negative wave in lead V1 indicated more distal origin in summit-CV. Target sites in proximal and distal summit-CV groups showed similar electrophysiological characteristics during mapping. CONCLUSIONS: There were significant differences in ECG characteristics of VAs at different portions of summit-CV, which could aid pre-procedure planning and facilitate radiofrequency catheter ablation (RFCA) procedures.


Subject(s)
Action Potentials , Catheter Ablation , Electrocardiography , Heart Rate , Heart Ventricles , Predictive Value of Tests , Humans , Catheter Ablation/adverse effects , Female , Male , Middle Aged , Adult , Treatment Outcome , Heart Ventricles/physiopathology , Heart Ventricles/surgery , Tachycardia, Ventricular/physiopathology , Tachycardia, Ventricular/surgery , Tachycardia, Ventricular/diagnosis , Electrophysiologic Techniques, Cardiac , Retrospective Studies , Aged
2.
Radiographics ; 44(9): e230222, 2024 09.
Article in English | MEDLINE | ID: mdl-39115996

ABSTRACT

Cardiac electrophysiology involves the diagnosis and management of arrhythmias. CT and MRI play an increasingly important role in cardiac electrophysiology, primarily in preprocedural planning of ablation procedures but also in procedural guidance and postprocedural follow-up. The most common applications include ablation for atrial fibrillation (AF), ablation for ventricular tachycardia (VT), and for planning cardiac resynchronization therapy (CRT). For AF ablation, preprocedural evaluation includes anatomic evaluation and planning using CT or MRI as well as evaluation for left atrial fibrosis using MRI, a marker of poor outcomes following ablation. Procedural guidance during AF ablation is achieved by fusing anatomic data from CT or MRI with electroanatomic mapping to guide the procedure. Postprocedural imaging with CT following AF ablation is commonly used to evaluate for complications such as pulmonary vein stenosis and atrioesophageal fistula. For VT ablation, both MRI and CT are used to identify scar, representing the arrhythmogenic substrate targeted for ablation, and to plan the optimal approach for ablation. CT or MR images may be fused with electroanatomic maps for intraprocedural guidance during VT ablation and may also be used to assess for complications following ablation. Finally, functional information from MRI may be used to identify patients who may benefit from CRT, and cardiac vein mapping with CT or MRI may assist in planning access. ©RSNA, 2024 Supplemental material is available for this article.


Subject(s)
Magnetic Resonance Imaging , Tomography, X-Ray Computed , Humans , Tomography, X-Ray Computed/methods , Magnetic Resonance Imaging/methods , Catheter Ablation/methods , Tachycardia, Ventricular/diagnostic imaging , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Electrophysiologic Techniques, Cardiac/methods , Arrhythmias, Cardiac/diagnostic imaging
3.
BMC Cardiovasc Disord ; 24(1): 347, 2024 Jul 08.
Article in English | MEDLINE | ID: mdl-38977958

ABSTRACT

BACKGROUND: CHA2DS2-VASc score-related differences have been reported in atrial fibrotic remodeling and prognosis of atrial fibrillation (AF) patients after ablation. There are currently no data on the efficacy of low voltage zone (LVZ)-guided ablation in persistent AF patients according to CHA2DS2-VASc score. We assessed in a cohort of persistent AF patients the extent of LVZ, the regional distribution of LA voltage and the outcome of LA voltage-guided substrate ablation in addition to PVI according to CHA2DS2-VASc score. METHODS: 138 consecutive persistent AF patients undergoing a first voltage-guided catheter ablation were enrolled. 58 patients with CHAD2DS2-VASc score ≥ 3 and 80 patients with CHAD2DS2-VASc score ≤ 2 were included. LA voltage maps were obtained using 3D-electroanatomical mapping system in sinus rhythm. LVZ was defined as < 0.5 mV. RESULTS: In the high CHAD2DS2-VASc score group, LA voltage was lower (1.5 [1.1-2.5] vs. 2.3 [1.5-2.8] mV, p = 0.02) and LVZs were more frequently identified (40% vs. 18%), p < 0.01). Female with CHA2DS2-VASc score ≥ 3 (p = 0.031), LA indexed volume (p = 0.009) and P-wave duration ≥ 150 ms (p = 0.001) were predictors of LVZ. After a 36-month follow-up, atrial arrhythmia-free survival was similar between the two groups (logrank test, P = 0.676). CONCLUSIONS: AF patients with CHAD2DS2-VASc score ≥ 3 display more LA substrate remodeling with lower voltage and more LVZs compared with those with CHAD2DS2-VASc score ≤ 2. Despite this atrial remodeling, they had similar and favorable 36 months results after one single procedure. Unlike male with CHAD2DS2-VASc score ≥ 3, female with CHAD2DS2-VASc score ≥ 3 was predictor of LVZ occurrence.


Subject(s)
Action Potentials , Atrial Fibrillation , Atrial Function, Left , Atrial Remodeling , Catheter Ablation , Predictive Value of Tests , Humans , Atrial Fibrillation/physiopathology , Atrial Fibrillation/surgery , Atrial Fibrillation/diagnosis , Atrial Fibrillation/mortality , Female , Male , Catheter Ablation/adverse effects , Middle Aged , Aged , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome , Heart Atria/physiopathology , Heart Atria/surgery , Heart Rate , Decision Support Techniques , Electrophysiologic Techniques, Cardiac , Recurrence , Retrospective Studies
5.
Europace ; 26(7)2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38988256

ABSTRACT

AIMS: A pulsed electric field (PF) energy source is a novel potential option for catheter ablation of ventricular arrhythmias (VAs) as it can create deeper lesions, particularly in scarred tissue. However, very limited data exist on its efficacy and safety. This prospective observational study reports the initial experience with VA ablation using focal PF. METHODS AND RESULTS: The study population consisted of 44 patients (16 women, aged 61 ± 14years) with either frequent ventricular premature complexes (VPCs, 48%) or scar-related ventricular tachycardia (VT, 52%). Ablation was performed using an irrigated 4 mm tip catheter and a commercially available PF generator. On average, 16 ± 15 PF applications (25 A) were delivered per patient. Acute success was achieved in 84% of patients as assessed by elimination of VPC or reaching non-inducibility of VT. In three cases (7%), a transient conduction system block was observed during PF applications remotely from the septum. Root analysis revealed that this event was caused by current leakage from the proximal shaft electrodes in contact with the basal interventricular septum. Acute elimination of VPC was achieved in 81% patients and non-inducibility of VT in 83% patients. At the 3-month follow-up, persistent suppression of the VPC was confirmed on Holter monitoring in 81% patients. In the VT group, the mean follow-up was 116 ± 75 days and a total of 52% patients remained free of any VA. CONCLUSION: Pulsed electric field catheter ablation of a broad spectrum of VA is feasible with acute high efficacy; however, the short-term follow-up is less satisfactory for patients with scar-related VT.


Subject(s)
Catheter Ablation , Tachycardia, Ventricular , Ventricular Premature Complexes , Humans , Female , Middle Aged , Male , Tachycardia, Ventricular/surgery , Tachycardia, Ventricular/physiopathology , Catheter Ablation/methods , Catheter Ablation/adverse effects , Treatment Outcome , Aged , Ventricular Premature Complexes/surgery , Ventricular Premature Complexes/physiopathology , Ventricular Premature Complexes/diagnosis , Prospective Studies , Cicatrix/etiology , Electrophysiologic Techniques, Cardiac
6.
BMC Cardiovasc Disord ; 24(1): 340, 2024 Jul 05.
Article in English | MEDLINE | ID: mdl-38970012

ABSTRACT

Atrial flutter, a prevalent cardiac arrhythmia, is primarily characterized by reentrant circuits in the right atrium. However, atypical forms of atrial flutter present distinct challenges in terms of diagnosis and treatment. In this study, we examine three noteworthy clinical cases of atypical atrial flutter, which offer compelling evidence indicating the implication of the lesser-known Septopulmonary Bundle (SPB). This inference is based on the identification of distinct electrocardiographic patterns observed in these patients and their favorable response to catheter ablation, which is a standard treatment for atrial flutter. Remarkably, in each case, targeted ablation at the anterior portion of the left atrial roof effectively terminated the arrhythmia, thus providing further support for the hypothesis of SPB involvement. These insightful observations shed light on the potential significance of the SPB in the etiology of atypical atrial flutter and introduce a promising therapeutic target. We anticipate that this paper will stimulate further exploration into the role of the SPB in atrial flutter and pave the way for the development of targeted ablation strategies.


Subject(s)
Action Potentials , Atrial Flutter , Catheter Ablation , Electrocardiography , Heart Rate , Atrial Flutter/physiopathology , Atrial Flutter/diagnosis , Atrial Flutter/surgery , Atrial Flutter/therapy , Atrial Flutter/etiology , Humans , Male , Treatment Outcome , Middle Aged , Female , Aged , Pericardium/physiopathology , Electrophysiologic Techniques, Cardiac
8.
Europace ; 26(8)2024 Aug 03.
Article in English | MEDLINE | ID: mdl-39082747

ABSTRACT

AIMS: Right phrenic nerve (RPN) injury is a disabling but uncommon complication of atrial fibrillation (AF) radiofrequency ablation. Pace-mapping is widely used to infer RPN's course, for limiting the risk of palsy by avoiding ablation at capture sites. However, information is lacking regarding the distance between the endocardial sites of capture and the actual anatomic RPN location. We aimed at determining the distance between endocardial sites of capture and anatomic CT location of the RPN, depending on the capture threshold. METHODS AND RESULTS: In consecutive patients undergoing AF radiofrequency ablation, we defined the course of the RPN on the electroanatomical map with high-output pacing at up to 50 mA/2 ms, and assessed RPN capture threshold (RPN-t). The true anatomic course of the RPN was delineated and segmented using CT scan, then merged with the electroanatomical map. The distance between pacing sites and the RPN was assessed. In 45 patients, 1033 pacing sites were analysed. Distances from pacing sites to RPN ranged from 7.5 ± 3.0 mm (min 1) when RPN-t was ≤10 mA to 19.2 ± 6.5 mm (min 9.4) in cases of non-capture at 50 mA. A distance to the phrenic nerve > 10 mm was predicted by RPN-t with a ROC curve area of 0.846 [0.821-0.870] (P < 0.001), with Se = 80.8% and Sp = 77.5% if RPN-t > 20 mA, Se = 68.0% and Sp = 91.6% if RPN-t > 30 mA, and Se = 42.4% and Sp = 97.6% if non-capture at 50 mA. CONCLUSION: These data emphasize the utility of high-output pace-mapping of the RPN. Non-capture at 50 mA/2 ms demonstrated very high specificity for predicting a distance to the RPN > 10 mm, ensuring safe radiofrequency delivery.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Imaging, Three-Dimensional , Peripheral Nerve Injuries , Phrenic Nerve , Predictive Value of Tests , Humans , Phrenic Nerve/injuries , Phrenic Nerve/diagnostic imaging , Atrial Fibrillation/surgery , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/physiopathology , Female , Male , Middle Aged , Aged , Catheter Ablation/methods , Peripheral Nerve Injuries/etiology , Peripheral Nerve Injuries/prevention & control , Treatment Outcome , Electrophysiologic Techniques, Cardiac , Tomography, X-Ray Computed , Cardiac Pacing, Artificial/methods , Radiographic Image Interpretation, Computer-Assisted , Action Potentials , ROC Curve
10.
Europace ; 26(7)2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38954426

ABSTRACT

AIMS: Prior case series showed promising results for cardioneuroablation in patients with vagally induced atrioventricular blocks (VAVBs). We aimed to examine the acute procedural characteristics and intermediate-term outcomes of electroanatomical-guided cardioneuroablation (EACNA) in patients with VAVB. METHODS AND RESULTS: This international multicentre retrospective registry included data collected from 20 centres. Patients presenting with symptomatic paroxysmal or persistent VAVB were included in the study. All patients underwent EACNA. Procedural success was defined by the acute reversal of atrioventricular blocks (AVBs) and complete abolition of atropine response. The primary outcome was occurrence of syncope and daytime second- or advanced-degree AVB on serial prolonged electrocardiogram monitoring during follow-up. A total of 130 patients underwent EACNA. Acute procedural success was achieved in 96.2% of the cases. During a median follow-up of 300 days (150, 496), the primary outcome occurred in 17/125 (14%) cases with acute procedural success (recurrence of AVB in 9 and new syncope in 8 cases). Operator experience and use of extracardiac vagal stimulation were similar for patients with and without primary outcomes. A history of atrial fibrillation, hypertension, and coronary artery disease was associated with a higher primary outcome occurrence. Only four patients with primary outcome required pacemaker placement during follow-up. CONCLUSION: This is the largest multicentre study demonstrating the feasibility of EACNA with encouraging intermediate-term outcomes in selected patients with VAVB. Studies investigating the effect on burden of daytime symptoms caused by the AVB are required to confirm these findings.


Subject(s)
Atrioventricular Block , Registries , Humans , Male , Female , Retrospective Studies , Aged , Middle Aged , Treatment Outcome , Atrioventricular Block/physiopathology , Atrioventricular Block/therapy , Atrioventricular Block/surgery , Catheter Ablation/methods , Time Factors , Vagus Nerve Stimulation/methods , Electrophysiologic Techniques, Cardiac , Syncope/etiology , Recurrence , Atrioventricular Node/surgery , Atrioventricular Node/physiopathology
12.
Pacing Clin Electrophysiol ; 47(8): 1079-1086, 2024 Aug.
Article in English | MEDLINE | ID: mdl-39031595

ABSTRACT

BACKGROUND: Identification of infrequent nonpulmonary vein trigger premature atrial contractions (PACs) is challenging. We hypothesized that pace mapping (PM) assessed by correlation scores calculated by an intracardiac pattern matching (ICPM) module was useful for locating PAC origins, and conducted a validation study to assess the accuracy of ICPM-guided PM. METHODS: Analyzed were 30 patients with atrial fibrillation. After pulmonary vein isolation, atrial pacing was performed at one or two of four sites on the anterior and posterior aspects of the left atrium (LA, n = 10/10), LA septum (n = 10), and lateral RA (n = 10), which was arbitrarily determined as PAC. The intracardiac activation obtained from each pacing was set as an ICPM reference consisting of six CS unipolar electrograms (CS group) or six CS unipolar electrograms and four RA electrograms (CS-RA group). RESULTS: The PM was performed at 193 ± 107 sites for each reference pacing site. All reference pacing sites corresponded to sites where the maximal ICPM correlation score was obtained. Sites with a correlation score ≥98% were rarely obtained in the CS-RA than CS group (33% vs. 55%, P = .04), but those ≥95% were similarly obtained between the two groups (93% vs. 88%, P = .71), and those ≥90% were obtained in all. The surface areas with correlation scores ≥98% (0[0,10] vs. 10[0,35] mm2, P = .02), ≥95% (10[10,30] vs. 50[10,180] mm2, P = .002) and ≥90% (60[30,100] vs. 170[100,560] mm2, P = .0002) were smaller in the CS-RA than CS group. CONCLUSIONS: ICPM-guided PM was useful for identifying the reference pacing sites. Combined use of RA and CS electrograms may improve the mapping quality.


Subject(s)
Atrial Fibrillation , Pulmonary Veins , Humans , Female , Male , Atrial Fibrillation/physiopathology , Atrial Fibrillation/surgery , Pulmonary Veins/physiopathology , Aged , Body Surface Potential Mapping/methods , Reproducibility of Results , Middle Aged , Electrophysiologic Techniques, Cardiac/methods , Sensitivity and Specificity , Heart Atria/physiopathology
13.
Circ Arrhythm Electrophysiol ; 17(8): e012829, 2024 Aug.
Article in English | MEDLINE | ID: mdl-39051110

ABSTRACT

BACKGROUND: The clinical outcome of pulmonary vein isolation (PVI) for persistent atrial fibrillation (AF) is suboptimal. Mapping studies have demonstrated atrial sites outside of the pulmonary veins displaying focal activation patterns during AF. We sought to determine whether adding catheter ablation of focal activation sites to PVI improves clinical outcomes of catheter ablation for persistent AF. METHODS: In this multicenter, randomized, single-blinded trial, we assigned patients with persistent AF to either PVI alone or to mapping-guided ablation of focal activation sites in addition to PVI in a 1:1 ratio. In the mapping-guided group, both atria were mapped after PVI using a Pentaray catheter (Biosense-Webster) and focal activation sites identified by CARTOFINDER (Biosense-Webster) were ablated. The primary end point was freedom from AF or atrial tachycardia without antiarrhythmic drugs beyond a 90-day blanking period. RESULTS: A total of 98 patients were assigned to the mapping-guided group and 102 to the PVI alone group. In the mapping-guided group, focal activation sites were identified at 2.6±0.3 and 2.5±0.2 sites per patient in the left and right atrium, respectively. Patients were followed up for 768.5 (interquartile range, 723.75-915.75) and 755.5 days (interquartile range, 728.5-913.75) in the mapping-guided ablation and the PVI alone groups, respectively. Freedom from AF/atrial tachycardia without antiarrhythmic drugs at 2-year follow-up was 66.8% and 75.2% in the mapping-guided ablation and the PVI alone groups, respectively (hazard ratio, 1.26 [95% CI, 0.76-2.10]; P=0.37). Adverse events occurred in 3 patients (3.0%) and none (0%) in the mapping-guided ablation and the PVI alone groups, respectively (P=0.12). CONCLUSIONS: In patients with persistent AF, the addition of mapping-guided ablation of focal activation sites to PVI did not improve clinical outcomes compared with PVI alone. REGISTRATION: URL: https://center6.umin.ac.jp/cgi-open-bin/ctr/index.cgi?function=02; Unique identifier: UMIN000037569.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnosis , Male , Female , Catheter Ablation/methods , Catheter Ablation/adverse effects , Pulmonary Veins/surgery , Pulmonary Veins/physiopathology , Single-Blind Method , Middle Aged , Aged , Heart Rate , Time Factors , Recurrence , Treatment Outcome , Electrophysiologic Techniques, Cardiac , Action Potentials
14.
JACC Clin Electrophysiol ; 10(7 Pt 2): 1576-1588, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38864810

ABSTRACT

BACKGROUND: Epicardial unipolar mapping has not been thoroughly investigated in Brugada syndrome (BrS). OBJECTIVES: This study aims to examine the characteristics of epicardial unipolar potentials in BrS and investigate the differences from overt cardiomyopathy. METHODS: Epicardial mapping was performed in 8 patients with BrS and 6 patients with cardiomyopathy. We investigated the J-wave amplitudes using unipolar recordings at delayed potential (DP) sites via bipolar recordings. The repolarization time (RT) at and around the DP recording sites was measured, and maximum dispersion of the RT divided by the distance was defined as the RT dispersion index. RESULTS: Epicardial mapping at baseline revealed significantly higher J-wave amplitude with bipolar DP in patients with BrS than in patients with cardiomyopathy. J-wave amplitude ≥0.42 mV had 99.1% sensitivity and 100% specificity for diagnosing BrS. The RT dispersion index was significantly higher in patients with BrS than in patients with cardiomyopathy at baseline. In all patients with BrS, coved-type unipolar electrograms without negative T waves (short RT) appeared close to coved-type electrograms with negative T waves (long RT) at the DP recording sites after pilsicainide administration. Thus, a steep RT dispersion was observed in this region, and ventricular arrhythmias emerged from this shorter RT area in all 3 patients with BrS in whom ventricular arrhythmias were induced. CONCLUSIONS: Bipolar DP-related prominent unipolar J waves and steep repolarization gradients may be more specific for characterizing BrS than for overt cardiomyopathy. Ventricular arrhythmias in BrS are associated with a steep repolarization gradient, indicating phase 2 re-entry as a possible cause.


Subject(s)
Brugada Syndrome , Electrocardiography , Epicardial Mapping , Humans , Brugada Syndrome/physiopathology , Male , Middle Aged , Female , Adult , Electrophysiologic Techniques, Cardiac/methods , Aged , Cardiomyopathies/physiopathology
16.
Circ Arrhythm Electrophysiol ; 17(7): e012684, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38939983

ABSTRACT

BACKGROUND: Atrial fibrillation (AF) and ventricular fibrillation (VF) episodes exhibit varying durations, with some spontaneously ending quickly while others persist. A quantitative framework to explain episode durations remains elusive. We hypothesized that observable self-terminating AF and VF episode lengths, whereby durations are known, would conform with a power law based on the ratio of system size and correlation length ([Formula: see text]. METHODS: Using data from computer simulations (2-dimensional sheet and 3-dimensional left-atrial), human ischemic VF recordings (256-electrode sock, n=12 patients), and human AF recordings (64-electrode basket-catheter, n=9 patients; 16-electrode high definition-grid catheter, n=42 patients), conformance with a power law was assessed using the Akaike information criterion, Bayesian information criterion, coefficient of determination (R2, significance=P<0.05) and maximum likelihood estimation. We analyzed fibrillatory episode durations and [Formula: see text], computed by taking the ratio between system size ([Formula: see text], chamber/simulation size) and correlation length (xi, estimated from pairwise correlation coefficients over electrode/node distance). RESULTS: In all computer models, the relationship between episode durations and [Formula: see text] was conformant with a power law (Aliev-Panfilov R2: 0.90, P<0.001; Courtemanche R2: 0.91, P<0.001; Luo-Rudy R2: 0.61, P<0.001). Observable clinical AF/VF durations were also conformant with a power law relationship (VF R2: 0.86, P<0.001; AF basket R2: 0.91, P<0.001; AF grid R2: 0.92, P<0.001). [Formula: see text] also differentiated between self-terminating and sustained episodes of AF and VF (P<0.001; all systems), as well as paroxysmal versus persistent AF (P<0.001). In comparison, other electrogram metrics showed no statistically significant differences (dominant frequency, Shannon Entropy, mean voltage, peak-peak voltage; P>0.05). CONCLUSIONS: Observable fibrillation episode durations are conformant with a power law based on system size and correlation length.


Subject(s)
Atrial Fibrillation , Ventricular Fibrillation , Humans , Ventricular Fibrillation/physiopathology , Ventricular Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnosis , Time Factors , Male , Female , Action Potentials , Computer Simulation , Heart Rate , Models, Cardiovascular , Middle Aged , Heart Conduction System/physiopathology , Electrophysiologic Techniques, Cardiac , Aged , Bayes Theorem
17.
J Cardiovasc Electrophysiol ; 35(6): 1174-1184, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38867544

ABSTRACT

INTRODUCTION: The left ventricular summit (LVS) is the highest point on the epicardial surface of the left ventricle. A part of the LVS that is located between the left coronary arteries (lateral-LVS) is one of the major sites of idiopathic ventricular arrhythmia (VA) origins. Some idiopathic epicardial VAs can be ablated at endocardial sites adjacent to the epicardial area septal to the lateral-LVS (septal-LVS). This study examined the prevalence and electrocardiographic and electrophysiological characteristics of septal-LVS VAs. METHODS: We studied consecutive patients with idiopathic VAs originating from the LVS (67 patients) and aortic root (93 patients). RESULTS: Based on the ablation results, among 67 LVS VAs, 54 were classified as lateral and 13 as septal-LVS VAs. As compared with the lateral-LVS VAs, the septal-LVS VAs were characterized by a greater prevalence of left bundle branch block with left inferior-axis QRS pattern, later precordial transition, lower R-wave amplitude ratio in leads III to II, lower Q-wave amplitude ratio in leads aVL to aVR, and later local ventricular activation time relative to the QRS onset during VAs (V-QRS) in the great cardiac vein. The electrocardiographic and electrophysiological characteristics of the septal-LVS VAs were similar to those of the aortic root VAs. However, the V-QRS at the successful ablation site was significantly later during the septal-LVS VAs than aortic root VAs (p < .0001). The precordial transition was significantly later during the septal-LVS VAs than aortic root VAs (p < .05). CONCLUSIONS: Septal-LVS VAs are considered a distinct subgroup of idiopathic VAs originating from the left ventricular outflow tract.


Subject(s)
Action Potentials , Catheter Ablation , Electrocardiography , Electrophysiologic Techniques, Cardiac , Predictive Value of Tests , Humans , Female , Male , Prevalence , Middle Aged , Adult , Aged , Treatment Outcome , Heart Rate , Heart Ventricles/physiopathology , Heart Ventricles/surgery , Tachycardia, Ventricular/physiopathology , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/surgery , Tachycardia, Ventricular/epidemiology , Retrospective Studies , Time Factors
18.
BMC Cardiovasc Disord ; 24(1): 316, 2024 Jun 24.
Article in English | MEDLINE | ID: mdl-38910261

ABSTRACT

BACKGROUND AND AIMS: Electrophysiological characteristics and radiofrequency catheter ablation (RFCA) of premature ventricular contractions (PVCs) originating from the superior septal left ventricle (SSLV) have not yet been fully characterized. METHODS AND RESULTS: This study included 247 patients who underwent RFCA for PVCs arising from the ventricular outflow tract between February 2020 and August 2022. The successful ablation site was on the SSLV in 37 of the 247 patients. In 12 (32.4%) of those 37 patients, a low amplitude and high frequency spiky potential (SP) was recognized. Five patients showed a narrow QRS duration (86.8 ± 4.6 ms), with a discrete SP observed in PVCs and sinus rhythm, which showed an isoelectric line with the ventricular electrogram at the earliest activation site. Seven patients showed a wide QRS duration (131.6 ± 4.5 ms), with SP observed in PVCs without an isoelectric line with the ventricular electrogram. RFCA was successful at the site of the earliest SP in all 12 patients. The time from SP onset at the successful ablation site to the QRS onset (local activation time) was 30 ± 12 ms, which differed significantly from that for the remaining 25 patients withoutSP(22.1 ± 7.1 ms, P < 0.05). CONCLUSIONS: SPs were recorded in 12 (32.4%) of the 37 patients with PVCs originating from the SSLV. The morphology of the PVCs may show a narrow or wide QRS duration and the target site for successful ablation should be identified by the earliest SP.


Subject(s)
Action Potentials , Catheter Ablation , Electrophysiologic Techniques, Cardiac , Heart Rate , Ventricular Premature Complexes , Humans , Catheter Ablation/adverse effects , Ventricular Premature Complexes/physiopathology , Ventricular Premature Complexes/surgery , Ventricular Premature Complexes/diagnosis , Male , Female , Middle Aged , Treatment Outcome , Adult , Time Factors , Retrospective Studies , Aged , Electrocardiography
19.
Europace ; 26(7)2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38833626

ABSTRACT

AIMS: Successful ventricular arrhythmia (VA) ablation requires identification of functionally critical sites during contact mapping. Estimation of the peak frequency (PF) component of the electrogram (EGM) may improve correct near-field (NF) annotation to identify circuit segments on the mapped surface. In turn, assessment of NF and far-field (FF) EGMs may delineate the three-dimensional path of a ventricular tachycardia (VT) circuit. METHODS AND RESULTS: A proprietary NF detection algorithm was applied retrospectively to scar-related re-entry VT maps and compared with manually reviewed maps employing first deflection (FDcorr) for VT activation maps and last deflection (LD) for substrate maps. Ventricular tachycardia isthmus location and characteristics mapped with FDcorr vs. NF were compared. Omnipolar low-voltage areas, late activating areas, and deceleration zones (DZ) in LD vs. NF substrate maps were compared. On substrate maps, PF estimation was compared between isthmus and bystander sites. Activation mapping with entrainment and/or VT termination with radiofrequency (RF) ablation confirmed critical sites. Eighteen patients with high-density VT activation and substrate maps (55.6% ischaemic) were included. Near-field detection correctly located critical parts of the circuit in 77.7% of the cases compared with manually reviewed VT maps as reference. In substrate maps, NF detection identified deceleration zones in 88.8% of cases, which overlapped with FDcorr VT isthmus in 72.2% compared with 83.3% overlap of DZ assessed by LD. Applied to substrate maps, PF as a stand-alone feature did not differentiate VT isthmus sites from low-voltage bystander sites. Omnipolar voltage was significantly higher at isthmus sites with longer EGM durations compared with low-voltage bystander sites. CONCLUSION: The NF algorithm may enable rapid high-density activation mapping of VT circuits in the NF of the mapped surface. Integrated assessment and combined analysis of NF and FF EGM-components could support characterization of three-dimensional VT circuits with intramural segments. For scar-related substrate mapping, PF as a stand-alone EGM feature did not enable the differentiation of functionally critical sites of the dominant VT from low-voltage bystander sites in this cohort.


Subject(s)
Algorithms , Catheter Ablation , Electrophysiologic Techniques, Cardiac , Tachycardia, Ventricular , Tachycardia, Ventricular/physiopathology , Tachycardia, Ventricular/surgery , Tachycardia, Ventricular/diagnosis , Humans , Catheter Ablation/methods , Electrophysiologic Techniques, Cardiac/methods , Female , Male , Retrospective Studies , Middle Aged , Action Potentials , Aged , Heart Rate , Predictive Value of Tests , Signal Processing, Computer-Assisted
SELECTION OF CITATIONS
SEARCH DETAIL