Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 3.293
Filter
1.
BMC Oral Health ; 24(1): 871, 2024 Aug 01.
Article in English | MEDLINE | ID: mdl-39090743

ABSTRACT

BACKGROUND: The aim of this research was to analyse the current literature on displaced dental implants in the mandibular body, including local and systemic variables related to their cause, and to identify the most frequent location. METHODS: The study conducted a search of three databases (Pubmed, Scopus, and Web of Science) using specific index terms such as 'dental implant', 'displacement', 'dislocation', 'displaced', and 'mandible'. The analysis focused on the direction of displacement and the characteristics of the bone tissue (bone quality, density, and quantity) in cases where dental implants were displaced. RESULTS: A total of 371 articles were obtained. Thirteen of these articles were selected and read in full. To define bone quality, the Lekholm and Zarb classification, modified by Rosas et al., was used. The type II-B bone, which is characterized by thick cortical bone surrounding cancellous bone with extremely wide medullary spaces, presented the largest number of complications. Twenty-two cases were found in which the displacement direction was horizontal. Of these, four were displaced vestibularly, fourteen lingually, and four remained in the center. Additionally, 24 cases presented vertical displacement, with 12 displaced towards the inferior border of the mandible, 9 towards the middle or adjacent to the inferior dental nerve canal, and 3 above the inferior dental nerve canal. CONCLUSION: The accidental displacement of implants within the mandibular body is associated with various risk factors, including the characteristics of the bony trabeculum and the size of the medullary spaces. It is reasonable to suggest that only an adequate pre-surgical diagnostic evaluation, with the help of high-resolution tomographic images that allow a previous evaluation of these structures, will help to have better control over the other factors, thus minimizing the risk of displacement.


Subject(s)
Dental Implants , Mandible , Humans , Dental Implants/adverse effects , Mandible/diagnostic imaging , Risk Factors , Foreign-Body Migration/prevention & control , Foreign-Body Migration/etiology , Bone Density , Dental Restoration Failure
8.
Jt Dis Relat Surg ; 35(2): 439-442, 2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38727126

ABSTRACT

Tension band wiring (TBW) is one of the most commonly used fixation techniques to fix olecranon osteotomies. Hardware prominence has been the most commonly reported complication of TBW. However, distal migration of Kirschner (K)-wire after TBW fixation for olecranon osteotomy has not been reported. In this case report, we presented distal migration of K-wire detected nine months after initial surgery in a 46-year-old male patient. The patient was operated on for an intraarticular distal humerus fracture using an olecranon osteotomy. The osteotomy was fixed with TBW fixation. The patient missed routine follow-ups and presented to the outpatient clinic with a complaint of skin irritation at the elbow nine months after the surgery. On radiological examination, distal migration of one K-wire was detected. The K-wire was surgically removed without any complication. Physicians should be aware of possible complications of TBW and remove fixation after fracture union to avoid unexpected complications.


Subject(s)
Bone Wires , Foreign-Body Migration , Olecranon Process , Osteotomy , Humans , Bone Wires/adverse effects , Male , Middle Aged , Olecranon Process/injuries , Olecranon Process/surgery , Olecranon Process/diagnostic imaging , Osteotomy/adverse effects , Osteotomy/methods , Osteotomy/instrumentation , Foreign-Body Migration/surgery , Foreign-Body Migration/diagnostic imaging , Foreign-Body Migration/etiology , Humeral Fractures/surgery , Humeral Fractures/diagnostic imaging , Fracture Fixation, Internal/adverse effects , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Device Removal/methods , Elbow Joint/surgery , Elbow Joint/diagnostic imaging , Intra-Articular Fractures/surgery , Intra-Articular Fractures/diagnostic imaging
10.
Dig Dis Sci ; 69(6): 2018-2025, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38580887

ABSTRACT

INTRODUCTION: Pancreatic duct stents (PDS) are widely used for the prevention of post-endoscopic retrograde cholangiopancreatography (ERCP) pancreatitis. However, there is a paucity of data regarding the adverse events associated with PDS placement. This study aims to investigate the reported adverse events and device failures related to PDS, utilizing the Manufacturer and User Facility Device Experience (MAUDE) database maintained by the U.S. Food and Drug Administration (FDA). METHODS: Post-marketing surveillance data from January 2013 to December 8, 2023, were extracted from the FDA's MAUDE database to analyze the reports pertaining to the use of commonly used PDS. The primary outcomes of interest were device issues and patient-related adverse events. Statistical analysis was performed using Microsoft Excel 2010, with the calculation of pooled numbers and percentages for each device and patient adverse event. RESULTS: A total of 579 device issues and 194 patient-related adverse events were identified. Device issues were primarily attributed to stent deformation (n = 72; 12.4%), followed by migration of the device into the pancreatic duct or expulsion out of the duct (n = 60; 10.4%), and stent fracture/breakage (n = 55; 9.4%). Among the patient-reported adverse events, inflammation was the most common (n = 26; 13.4%), followed by reports of stents becoming embedded in tissue (n = 21; 10.8%) and stent occlusion/obstruction (n = 16; 8.2%). The most prevalent device failures associated with Advanix stents were material deformation, with perforation (n = 3, 30%) being the most frequently reported adverse event. Concerning Geenen stents, migration or expulsion of the device (n = 34, 16.9%) constituted the most common device-related adverse events, while inflammation (n = 20, 16.7%) was the most frequently reported patient-related issue. For Zimmon stents, migration or expulsion of the device (n = 22, 8.8%) were the most frequently reported device-related problems, whereas perforation (n = 7, 10.9%) and bleeding (n = 7, 10.9%) were the most frequent patient-related adverse events. CONCLUSION: Our findings highlight important device and patient adverse events that endoscopists and referring providers should be aware of before considering pancreatic stent placement.


Subject(s)
Databases, Factual , Pancreatic Ducts , Product Surveillance, Postmarketing , Prosthesis Failure , Stents , United States Food and Drug Administration , Humans , United States/epidemiology , Stents/adverse effects , Pancreatic Ducts/surgery , Cholangiopancreatography, Endoscopic Retrograde/adverse effects , Cholangiopancreatography, Endoscopic Retrograde/instrumentation , Pancreatitis/etiology , Pancreatitis/epidemiology , Pancreatitis/prevention & control , Equipment Failure/statistics & numerical data , Foreign-Body Migration/etiology , Foreign-Body Migration/epidemiology , Foreign-Body Migration/prevention & control
11.
Catheter Cardiovasc Interv ; 103(7): 1152-1155, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38606476

ABSTRACT

The use of left atrial appendage occlusion (LAAO) devices have gained prominence as an alternative to long-term anticoagulation therapy in patients with atrial fibrillation at risk of stroke and high risk of bleeding. While these devices have shown efficacy in reducing stroke risk, there have been reported cases of embolization of the Watchman device. There are very few cases of successful percutaneous retrieval of embolized Watchman devices from the left ventricle (LV), as many of these cases require open heart surgery for safe removal. We are presenting a case of an 80-year-old male whose Watchman device embolized to the LV and was entrapped on the LV papillary muscle that was then successfully retrieved via percutaneous methods, which shows the percutaneous options remain a viable strategy to retrieve LAAO devices from the LV.


Subject(s)
Atrial Fibrillation , Cardiac Catheterization , Device Removal , Foreign-Body Migration , Papillary Muscles , Humans , Male , Aged, 80 and over , Treatment Outcome , Atrial Fibrillation/therapy , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnosis , Cardiac Catheterization/instrumentation , Cardiac Catheterization/adverse effects , Foreign-Body Migration/therapy , Foreign-Body Migration/etiology , Foreign-Body Migration/diagnostic imaging , Papillary Muscles/diagnostic imaging , Heart Ventricles/diagnostic imaging , Embolism/etiology , Embolism/diagnostic imaging , Embolism/therapy , Embolism/diagnosis , Atrial Appendage/diagnostic imaging , Atrial Appendage/physiopathology , Echocardiography, Transesophageal
12.
Rev Esp Anestesiol Reanim (Engl Ed) ; 71(4): 291-297, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38431047

ABSTRACT

BACKGROUND: Continuous peripheral nerve blocks are commonly used for pain management. However, the incidence of catheter dislodgement or migration is unclear, and may be underestimated and underreported. Our objective was to assess suprascapular catheter tip positioning before and after routine simulated shoulder physiotherapy manipulation in an anatomical cadaver model. METHOD: Eight ultrasound-guided continuous suprascapular nerve block catheters were placed in cryopreserved fresh cadavers. Computed tomography (CT) confirmed the location of the catheter tip after injection of 1 ml of contrast medium. We performed a series of standardized shoulder movements during a simulated shoulder physiotherapy session in cadavers. Following this, we administered 1 ml of methylene blue through the catheters, and then performed anatomical dissections to accurately identify the location of the catheter tips and compare them to their placement prior to the 'physiotherapy'. RESULT: CT imaging confirmed the location of the catheter tips at the suprascapular notch in all cases. However, following physiotherapy, 2 catheters (25%) were found to have migrated - specifically, 1 was located in the supraspinatus muscle, and the other was located in the trapezius muscle. CONCLUSION: Our findings suggest that catheter dislodgement may occur in approximately 25% of cases following simulated physiotherapy manipulation. However, further research is needed to determine the read incidence of catheter dislodgement in clinical practice.


Subject(s)
Cadaver , Nerve Block , Humans , Nerve Block/methods , Nerve Block/instrumentation , Physical Therapy Modalities , Catheters , Tomography, X-Ray Computed , Ultrasonography, Interventional , Foreign-Body Migration/diagnostic imaging , Foreign-Body Migration/etiology , Male , Shoulder
13.
J Vasc Interv Radiol ; 35(6): 890-894, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38447770

ABSTRACT

This report describes the experience of removing migrated gastrointestinal (GI) stents using a gastrostomy (G) access. Four male patients aged 23-62 years (mean, 42 years) had 6 migrated stents removed using an existing (n = 3) or new (n = 1) G access. Removed stents included 5 covered esophageal stents that migrated into the stomach and 1 distal noncovered duodenal stent that migrated into the proximal duodenum. One patient had 2 stents removed during the same session. All stents were removed successfully without adverse events. Techniques used included the folding technique using a wire in 3 stents and forceps in 2 stents. Eversion technique was used in the duodenal stent. The G or gastrojejunostomy tubes were replaced after stent removal and used for enteral feedings. In conclusion, removing migrated GI stents using an existing or new G access was technically successful and safe.


Subject(s)
Device Removal , Foreign-Body Migration , Gastrostomy , Stents , Adult , Humans , Male , Middle Aged , Young Adult , Foreign-Body Migration/diagnostic imaging , Foreign-Body Migration/etiology , Foreign-Body Migration/therapy , Foreign-Body Migration/surgery , Gastrostomy/instrumentation , Gastrostomy/adverse effects , Treatment Outcome
14.
Urol Int ; 108(3): 272-275, 2024.
Article in English | MEDLINE | ID: mdl-38377979

ABSTRACT

INTRODUCTION: Approximately 5% of bladder stones occur in women and are usually associated with foreign bodies or urinary stasis. Spontaneous migration of the intrauterine device (IUD) into the bladder is a rare complication. In this report, we present 2 cases of migrated IUD who had undergone surgery at our clinic due to bladder stones. CASE PRESENTATIONS: We detected migrated IUDs into the bladder in 2 female patients, aged 37 and 56 years, who presented with lower urinary tract symptoms and urinary tract infection. In the first case, endoscopic cystolithotripsy was performed, and the IUD was removed without complications. In the second case, the IUD could not be removed endoscopically since it had fractionally invaded the bladder wall, and the IUD was removed without complications by performing an open cystolithotomy. CONCLUSION: A comprehensive gynecological history should be taken from every female patient presenting with recurrent urinary tract infections and lower urinary tract symptoms. If these patients have a history of IUD placement, the possibility of the intravesical migration of this device should be kept in mind.


Subject(s)
Intrauterine Device Migration , Intrauterine Devices , Lithotripsy , Urinary Bladder Calculi , Humans , Female , Urinary Bladder Calculi/etiology , Urinary Bladder Calculi/surgery , Adult , Middle Aged , Intrauterine Devices/adverse effects , Intrauterine Device Migration/adverse effects , Lithotripsy/adverse effects , Foreign-Body Migration/etiology , Foreign-Body Migration/surgery , Urinary Bladder/surgery , Cystoscopy , Device Removal , Urinary Tract Infections/etiology , Treatment Outcome
16.
J Vasc Surg ; 79(6): 1369-1378, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38316346

ABSTRACT

OBJECTIVE: There are a variety of methods used today to treat common iliac aneurysms with endovascular techniques. Of these approaches, little is known about whether a particular limb strategy influences endoleak, reintervention, or aneurysm regression rates. We present 5-year data comparing endoleak, stent graft migration, fracture, aneurysm sac dynamics, and aortic rupture rates among patients treated with bell bottom limbs (BB), iliac branch endoprosthesis (IBE), and coil and cover (CC) approaches from the Global Registry for Endovascular Aortic Treatment registry. Secondary end points were all-cause mortality, stroke, reintervention, and paraplegia. METHODS: Subjects from the GORE Global Registry for Endovascular Aortic Treatment were enrolled over a 5-year period from October 2017 to August 2022. We included 924 subjects in this study. Statistical data was generated on R software and limb groups were compared using the Pearson's χ2 test and the Kruskal-Wallis rank-sum test. RESULTS: We found no statistical difference in endoleak rates, stent graft migration, fracture, or aortic rupture when stratified by limb strategy. There was no difference between limb approaches with regard to aneurysm sac dynamics among those with abdominal aortic aneurysms and common iliac aneurysms. Similarly, no statistical difference between limb strategies was found in all-cause mortality, stroke, paraplegia, or reintervention rates. Among patients that required an additional graft during reintervention, the highest rates were found within the IBE group 8.6%, compared with BB group 2.2% and CC group 1.3% (P = .006). CONCLUSIONS: Overall, there was no difference among limb strategies in endoleak rates, stent graft migration, aneurysm sac dynamics, aortic rupture rates, or our secondary end points. Increased rates of reintervention requiring an additional graft within the IBE group is noteworthy and must be weighed against the adverse effects of hypogastric sacrifice with the CC approach or potentially less advantageous seal zones in the BB approach. This finding suggests that all limb approaches have equivalent effectiveness in managing the aneurysmal common iliac artery; thus, the choice of limb strategy should be individualized and remain at physician discretion. Future research should include a more robust sample size to reproduce these findings.


Subject(s)
Blood Vessel Prosthesis Implantation , Blood Vessel Prosthesis , Endovascular Procedures , Iliac Aneurysm , Prosthesis Design , Registries , Stents , Humans , Iliac Aneurysm/surgery , Iliac Aneurysm/mortality , Iliac Aneurysm/diagnostic imaging , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Endovascular Procedures/mortality , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/mortality , Male , Female , Treatment Outcome , Time Factors , Aged , Risk Factors , Endoleak/etiology , Endoleak/surgery , Aged, 80 and over , Aortic Rupture/surgery , Aortic Rupture/mortality , Aortic Rupture/diagnostic imaging , Prosthesis Failure , Retrospective Studies , Risk Assessment , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/mortality , Aortic Aneurysm, Abdominal/diagnostic imaging , Foreign-Body Migration/etiology
17.
Dermatol Surg ; 50(5): 453-458, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38386847

ABSTRACT

BACKGROUND: Traditionally, hyaluronidase (HYAL) is used after hyaluronic acid (HA) injection to dissolve the undesired migration of product. OBJECTIVE: To describe a novel lip augmentation technique that uses HA and HYAL simultaneously in patients who previously had HA migration. METHODS AND MATERIALS: Nine hundred twenty female patients were included. In the first group ( n = 793), HA injections were performed in subcutaneous plane of the lips. In the second group who had previous product migration ( n = 127), 7.5 units of HYAL is injected in 4 points in ergotrid area before proceeding with HA injection. RESULTS: The medicis lip fullness scale scores after 2 weeks improved in all patients, while 92% of patients perceived the results as "very much improved" with Global Aesthetic Improvement Scale ( p ˂ .001). There was no difference between 2 groups regarding the patient satisfaction rates ( p ˃.05), while filler migration was seen in 0.2% ( n : 15) of patients in the first group during the follow-up period. CONCLUSION: The new vertical injection approach provided an increased vertical height, optimal eversion, and an incisor display on the lips. The simultaneous use of HYAL before HA injection seems to be a safe and effective practice in 1-stage treatment of the previously injected lips with filler migration into ergotrid area.


Subject(s)
Cosmetic Techniques , Dermal Fillers , Hyaluronic Acid , Hyaluronoglucosaminidase , Lip , Patient Satisfaction , Humans , Female , Hyaluronic Acid/administration & dosage , Hyaluronic Acid/adverse effects , Retrospective Studies , Dermal Fillers/administration & dosage , Dermal Fillers/adverse effects , Adult , Middle Aged , Hyaluronoglucosaminidase/administration & dosage , Aged , Injections, Subcutaneous , Esthetics , Treatment Outcome , Foreign-Body Migration/etiology
18.
J Cardiothorac Surg ; 19(1): 101, 2024 Feb 19.
Article in English | MEDLINE | ID: mdl-38374106

ABSTRACT

BACKGROUND: Acupuncture, a traditional Chinese medical treatment, has been gaining popularity over the years. However, it also presents certain risks. We report a case of a patient who discovered a foreign body in their lung several years after undergoing acupuncture. CASE PRESENTATION: A middle-aged woman presented to our hospital with chest pain. An X-ray revealed a needle-like foreign body in the middle lobe of her right lung. The patient had previously undergone acupuncture treatment for local pain in her lower back and lower extremities many years prior. Based on the imaging findings and her medical history, we hypothesized that the foreign body in her lung was a result of a dislodged acupuncture needle. Through preoperative 3-dimensional reconstruction and indocyanine green localization, we were able to locate the foreign body in the lateral segment of the right middle lobe. We successfully removed the foreign body via wedge resection, and the patient made a smooth recovery post-surgery. CONCLUSION: Acupuncturists and surgeons should remain vigilant about the potential risks associated with acupuncture.


Subject(s)
Acupuncture Therapy , Foreign Bodies , Foreign-Body Migration , Humans , Middle Aged , Female , Needles/adverse effects , Acupuncture Therapy/adverse effects , Foreign Bodies/diagnostic imaging , Foreign Bodies/etiology , Foreign Bodies/surgery , Radiography , Chest Pain , Foreign-Body Migration/diagnostic imaging , Foreign-Body Migration/etiology
SELECTION OF CITATIONS
SEARCH DETAIL