Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 12.302
Filter
1.
Article in English | MEDLINE | ID: mdl-39236262

ABSTRACT

INTRODUCTION: Femoral shaft nonunion negatively affects patient quality of life. Although multiple risk factors have been identified for femoral shaft nonunion after intramedullary nail (IMN) fixation, there is no quantitative model for predicting nonunion. STUDY DESCRIPTION: The study is a retrospective cohort study of patients with femoral shaft fractures treated at two level one trauma centers who were followed to fracture union or nonunion. Patient, injury, and surgical characteristics were analyzed to create a quantitative model for nonunion risk after intramedullary nailing. METHODS: Eight hundred one patients aged 18 years and older with femoral shaft fractures treated with reamed, locked IMNs were identified. Risk factors including demographics, comorbidities, surgical variables, and injury-related characteristics were evaluated. Multivariate analysis was conducted, and several variables were included in a scoring system to predict nonunion risk. RESULTS: The overall nonunion rate was 7.62% (61/801). Multivariate analysis showed significant association among pulmonary injury (odds ratio [OR] = 2.19, P = 0.022), open fracture (OR=2.36, P = 0.02), current smoking (OR=3.05, P < 0.001), postoperative infection (OR=12.1, P = 0.007), AO/OTA fracture pattern type A or B (OR=0.43, P = 0.014), and percent cortical contact obtained intraoperatively ≥25% (OR=0.41, P = 0.021) and nonunion. The scoring system created to quantitatively stratify nonunion risk showed that a score of 3 or more yielded an OR of 6.38 for nonunion (c-statistic = 0.693, P < 0.0001). CONCLUSIONS: Femoral shaft nonunion risk is quantifiable based on several independent injury, patient, and surgical factors. This scoring system is an additional tool for clinical decision making when caring for patients with femoral shaft fractures treated with IMNs.


Subject(s)
Femoral Fractures , Fracture Fixation, Intramedullary , Fractures, Ununited , Humans , Femoral Fractures/surgery , Male , Female , Retrospective Studies , Adult , Middle Aged , Risk Factors , Aged , Young Adult , Risk Assessment
2.
Article in English | MEDLINE | ID: mdl-39240759

ABSTRACT

Several challenges exist for the foot and ankle surgeon when addressing the complications associated with ankle fracture repair. The risk of joint destruction, debilitation, and even limb loss may be amplified by the noncompliant patient. There is an abundance of literature documenting the management of fracture nonunions in the setting of infection with a variety of techniques proven successful in managing large osseous defects and eradicating infection. We present a particularly challenging case in which we modified an existing method of treatment to preserve the ankle joint of a failed reduction complicated by septic nonunion following placement of a fibular intramedullary nail.


Subject(s)
Fracture Fixation, Intramedullary , Fractures, Ununited , Limb Salvage , Humans , Fractures, Ununited/surgery , Fractures, Ununited/etiology , Fracture Fixation, Intramedullary/adverse effects , Limb Salvage/methods , Fibula/surgery , Fibula/injuries , Male , Bone Nails/adverse effects , Ankle Fractures/surgery
3.
JBJS Case Connect ; 14(3)2024 Jul 01.
Article in English | MEDLINE | ID: mdl-39241095

ABSTRACT

CASE: A 39-year-old man fell during a mountain hike and injured his left, nondominant ring finger, presenting with swelling, tenderness, and crepitus of the proximal interphalangeal joint. A computed tomography scan demonstrated a displaced intra-articular impaction fracture of the middle phalanx base. Surgery was performed with a combination of intramedullary reduction by K-wire and dynamic external fixation, using a Suzuki frame, to allow early active motion and prevent collapse of the reduced fragments. At 1-year follow-up, the clinical and radiological results were excellent. CONCLUSION: The impaction fracture of our patient was successfully treated with Suzuki pins and rubber after intramedullary reduction by K-wire.


Subject(s)
Fracture Fixation, Intramedullary , Humans , Male , Adult , Fracture Fixation, Intramedullary/instrumentation , Traction/instrumentation , Bone Nails , Finger Injuries/surgery , Finger Injuries/diagnostic imaging , Rubber , Bone Wires
4.
Unfallchirurgie (Heidelb) ; 127(10): 722-728, 2024 Oct.
Article in German | MEDLINE | ID: mdl-39266714

ABSTRACT

BACKGROUND: The pertrochanteric femoral fracture (PFF) represents one of the most common fracture types throughout Germany. To enable early mobilization of patients, the primary surgical goal is load-stable osteosynthesis. Implant failure still represents the largest group of implant-related complications (>80%). OBJECTIVE: The aim of the study was to document and analyze the influence of the implant on the functional outcome and an evaluation of the rotationally stable screw anchor (RoSA) vs. Gamma3 nail. MATERIAL AND METHODS: In a retrospective study 43 patients with PFF (AO 31A1-A3) were included in the study. The influence of the implant on the functional outcome was assessed by 2 standardized questionnaires (SF-36, NMS (New Mobility Score)) and analyzed in a retrospective evaluation. RESULTS: In the study no significant differences in functional outcome scores ≥ 1 year after osteosynthesis of the PFF could be shown depending on the implant used. There is an overall tendency for a better outcome in the G3N group. DISCUSSION/CONCLUSION: In the literature the superiority of intramedullary nailing over extramedullary implants is continually discussed. Implant failure is still the most frequent complication. In intramedullary implants, such as the G3N, the primary cause is failure of the head-neck component. For conventional extramedullary implants the biomechanical properties on the femoral shaft also pose a challenge in the case of unstable PFF. The further development of the RoSA to an intramedullary implant could combine the advantages of intramedullary load carriers with the advantages of the blade-screw combination in the head-neck fragment and lead to a reduction in implant-associated complications.


Subject(s)
Bone Nails , Bone Screws , Humans , Female , Male , Retrospective Studies , Aged , Treatment Outcome , Middle Aged , Aged, 80 and over , Fracture Fixation, Intramedullary/instrumentation , Fracture Fixation, Intramedullary/methods , Fracture Fixation, Intramedullary/adverse effects , Hip Fractures/surgery , Femoral Fractures/surgery , Prosthesis Design , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation
5.
J Orthop Surg Res ; 19(1): 583, 2024 Sep 20.
Article in English | MEDLINE | ID: mdl-39304891

ABSTRACT

OBJECTIVE: Given the recent application of two new types of intramedullary nail devices in the treatment of comminuted femoral intertrochanteric fractures (CFIFs), there is still a lack of deep understanding and comparative evaluation of their biomechanical properties. Therefore, this study aims to systematically compare the advantages and disadvantages of these two new devices with traditional proximal femoral nail antirotation (PFNA) and InterTan nails in the fixation of CFIFs through finite element analysis. METHODS: Based on the validated finite element model, this study constructed an accurate CFIFs model. In this model, PFNA, InterTan nails, proximal femoral bionic nails (PFBN), and new intramedullary systems (NIS) were implanted, totaling four groups of finite element models. Each group of models was subjected to simulation tests under a vertical load of 2100 N to evaluate the displacement and Von Mises stress (VMS) distribution of the femur and intramedullary nail devices. RESULTS: Under a vertical load of 2100 N, a comparative analysis of the four finite element models showed that the NIS device exhibited the most superior performance in terms of peak displacement, while the PFNA device performed relatively poorly. Although the NIS device had the highest peak stress in the femur, it had the smallest peak displacement of both the femur and intramedullary nail devices, and the peak stress was mainly concentrated on the lateral side of the femur, with significantly lower stress in the proximal femur compared to the other three intramedullary nail devices. In contrast, the PFBN device had the lowest peak stress in the femur, and its peak displacement of both the femur and intramedullary nail devices was also less than that of PFNA and InterTan nails. CONCLUSION: This study demonstrates that in the treatment of CFIFs, PFBN and NIS devices exhibit superior biomechanical performance compared to traditional PFNA and InterTan nail devices. Especially the NIS device, which can achieve good biomechanical results when fixing femoral intertrochanteric fractures with missing medial wall. Therefore, both PFBN and NIS devices can be considered reliable closed reduction and internal fixation techniques for the treatment of CFIFs, with potential clinical application value.


Subject(s)
Bone Nails , Finite Element Analysis , Fracture Fixation, Intramedullary , Fractures, Comminuted , Hip Fractures , Humans , Fracture Fixation, Intramedullary/methods , Fracture Fixation, Intramedullary/instrumentation , Biomechanical Phenomena , Hip Fractures/surgery , Fractures, Comminuted/surgery , Femur/surgery
6.
Medicine (Baltimore) ; 103(37): e39676, 2024 Sep 13.
Article in English | MEDLINE | ID: mdl-39287232

ABSTRACT

OBJECTIVE: Although a large body of evidence has reported on surgical approaches for the treatment of unstable intertrochanteric femoral fractures, studies that comprehensively evaluate treatment outcomes are limited. The purpose of this study was to compare the effectiveness of extramedullary fixation (i.e., dynamic hip screw [DHS]), intramedullary fixation (i.e., the proximal femoral nailing [PFN]), and hemiarthroplasty (HA) for the treatment of unstable intertrochanteric femoral fractures using network meta-analysis. METHODS: This study meets the preferred reporting items for systematic reviews and meta-analyses criteria. The Patient, Intervention, Comparison and Outcome search protocol framework was used to search the Google Scholar, PubMed, Embase, and Cochrane Library databases were searched from inception until June 2023. RESULTS: A total of 15 randomized controlled trials, including 1282 patients were analyzed. The Harris hip score (HHS) after DHS fixation was the lowest compared with that of PFN fixation and HA. DHS fixation had a significantly longer operation time than that of PFN fixation. Compared with HA, a lower incidence of superficial wound infection was observed with PFN and DHS fixations. PFN was significantly more likely to be implant cut out compared with HA. Compared with DHS, PFN and HA showed a lower incidence of fracture healing malunion. CONCLUSION: HA and PFN have good efficacy in improving the HHS and preventing joint deformities. However, HA showed a higher incidence of superficial infection than that observed with PFN, whereas a higher risk of screw cutout is observed with PFN than with HA.


Subject(s)
Hip Fractures , Network Meta-Analysis , Humans , Hip Fractures/surgery , Fracture Fixation, Intramedullary/methods , Hemiarthroplasty/methods , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/adverse effects , Bone Screws , Bone Nails , Treatment Outcome , Operative Time , Randomized Controlled Trials as Topic
7.
JBJS Case Connect ; 14(3)2024 Jul 01.
Article in English | MEDLINE | ID: mdl-39270038

ABSTRACT

CASE: A 34-year-old man with a distal tibia bone defect was treated with an intramedullary bone transport nail (Precice Bone Transport System, NuVasive). During planned removal after successful treatment, 7 separate subcomponents of the nail became disconnected and had to be separately removed using specialized instrumentation. This occurred despite adherence to the manufacturer's recommended technique for nail removal and in the absence of clinical or radiographic evidence of implant failure. CONCLUSION: When planning for implant removal, surgeons should be aware of potential intraoperative disconnection of subcomponents of this magnetic bone transport nail and ensure that equipment for retrieval (e.g., very long endoscopy forceps) is available.


Subject(s)
Bone Nails , Device Removal , Tibial Fractures , Humans , Male , Adult , Device Removal/methods , Tibial Fractures/surgery , Tibial Fractures/diagnostic imaging , Fracture Fixation, Intramedullary/instrumentation
8.
Unfallchirurgie (Heidelb) ; 127(10): 713-721, 2024 Oct.
Article in German | MEDLINE | ID: mdl-39283533

ABSTRACT

BACKGROUND: To break or not to break-That is the question that has been asked in pediatric traumatology for many years regarding the treatment of greenstick fractures of the diaphyseal forearm shaft. OBJECTIVE: The frequency of greenstick fractures of the forearm shaft in children and adolescents; the influence of breaking the fracture on the refracture rate. METHODS: Analysis and discussion of relevant articles, analysis of the refracture rate of pediatric greenstick fractures of the forearm shaft in our own patient population. RESULTS: Greenstick fractures frequently occur in the area of the forearm shaft and incomplete consolidation leads to an increased refracture rate. In the patient collective of the authors of 420 children with greenstick fractures of the diaphyseal forearm, there was a refracture rate of 9.5%; however, the rate for non-completed fractures was significantly higher compared to the group with completed fractures (15.2% vs. 3%). While in the subgroup of conservatively treated fractures (n = 234), breaking the intact cortex significantly reduced the refracture rate, breaking the intact cortical bone during surgical treatment with elastic stable intramedullary nailing (ESIN) did not change the refracture rate. CONCLUSION: As part of the conservative treatment of greenstick fractures of the diaphyseal forearm, completing the fracture can be recommended in order to lower the refracture rate. Completing the fracture does not appear to be necessary during surgical treatment using ESIN.


Subject(s)
Radius Fractures , Ulna Fractures , Humans , Child , Radius Fractures/surgery , Radius Fractures/therapy , Ulna Fractures/surgery , Adolescent , Male , Female , Fracture Fixation, Intramedullary/methods , Fracture Fixation, Intramedullary/instrumentation , Forearm Injuries/surgery , Child, Preschool , Diaphyses/injuries , Cortical Bone/injuries
9.
Medicine (Baltimore) ; 103(22): e38353, 2024 May 31.
Article in English | MEDLINE | ID: mdl-39259099

ABSTRACT

BACKGROUND: Distal tibial fractures remains a significant challenge in orthopedic trauma surgery. As the fracture level approaches the joint, alternative fixation options instead of intramedullary nailing (IMN) come to the fore. The present study aimed to assess the biomechanical stability of IMN at different distal tibial fracture levels and the number of locking screws required. METHODS: Using a total of 21 sawbone models, 3 different tibial fracture levels (3, 4.5, and 6 cm proximally to the talocrural joint) were created and the fractures were fixed using 2, 3, or 4 distal locking screws. A single compression force at a speed of 30 mm/min with a maximum force of 800 Newton and a cyclic compression force of 60 cycles at a speed of 60 mm/min was applied to all tibia models. The applied weight and displacements from the fracture lines were recorded and evaluated. RESULTS: There was no statistically significant difference in fixation with 2 distal locking screws in groups 1, 2, and 3 (single test P =.9689) (cyclic test P =.8050). Therefore, if 2 distal screws are used, the fracture level does not affect the strength of fixation. In fractures located 6 cm proximal to the talocrural joint, all 4 holes of the nail can be used to insert screws, which provides a stronger fixation. When 2 screws are used, a statistically weaker fixation is obtained than with 3 or 4 screws. However, there is no significant difference between using 3 or 4 screws. CONCLUSION: Our findings support the use of IMN with 2 distal locking screws as a viable option for the management of distal tibial fractures. We found that it provides sufficient fixation regardless of the fracture level, suggesting that there is no need to choose an alternative fixation technique due to concerns of inadequate fixation as the fracture line moves distally. In cases where more stable fixation is desired, an additional locking screw can be used, but the potential increase in procedure and fluoroscopy time should be considered.


Subject(s)
Bone Screws , Fracture Fixation, Intramedullary , Tibial Fractures , Fracture Fixation, Intramedullary/methods , Fracture Fixation, Intramedullary/instrumentation , Tibial Fractures/surgery , Humans , Biomechanical Phenomena , Bone Nails , Models, Anatomic
10.
PeerJ ; 12: e18020, 2024.
Article in English | MEDLINE | ID: mdl-39308830

ABSTRACT

Objective: Cephalomedullary nails (CMN) are implants with a high success rate in the surgical treatment of trochanteric fractures. The aim of this study is to compare the radiological outcomes and mechanical complications of femoral trochanteric fractures treated with three different CMNs. Methods: Intertrochanteric fractures in patients aged 50 years and older treated with CMN between January 2016 and December 2021 were reviewed retrospectively. A total of 158 cases meeting the criteria were included to final analysis. Cases were divided into three groups based on the type of nail used (helical blade: group 1, n = 54; screw: group 2, n = 53; winged screw: group 3, n = 51). Demographic characteristics, mechanical complications, reduction quality, tip-apex distances (TAD) and Cleveland zones were compared between the groups. Femoral neck shortening, varus collapse, lag sliding, changes in abductor length were compared between study groups. Factors affecting mechanical complications were also analyzed. Results: Study groups were homogenic in terms of demographic characteristics, fracture type and reduction quality. Regarding mechanical complications, no statistically significant difference was found between groups. All three implants had similar outcomes on femoral neck shortening, varus collapse and lag sliding. Pooled analysis of 158 cases showed that mechanical complications increase as the quality of reduction decreases (p = 0.000) same applies when TAD alters from the desired range (p = 0.025) and with non-optimally implanted blade according to Cleveland zones (p = 0, 000). Conclusion: The radiological outcomes and mechanical complications of helical blade, screw type blade and winged screw type blade proximal femoral nails are similar in selected group. Regardless of the device type, it is necessary to obtain high reduction quality, obtain TAD within described range and optimally place the blade according to Cleveland Zones to reduce the failure rate and avoid complications.


Subject(s)
Bone Nails , Bone Screws , Fracture Fixation, Intramedullary , Hip Fractures , Humans , Male , Female , Retrospective Studies , Fracture Fixation, Intramedullary/instrumentation , Fracture Fixation, Intramedullary/methods , Aged , Hip Fractures/surgery , Hip Fractures/diagnostic imaging , Middle Aged , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Aged, 80 and over , Treatment Outcome , Radiography
11.
Med Eng Phys ; 131: 104230, 2024 09.
Article in English | MEDLINE | ID: mdl-39284656

ABSTRACT

There is currently no definitive evidence for the implant of choice for the treatment of reverse pertrochanteric fractures. Here, we aimed to compare the stability provided by two implant options: long and short intramedullary nails. We performed finite element simulations of different patterns of reverse pertrochanteric fractures with varying bone quality, and compared the short vs long nail stabilization under physiological loads. For each variable combination, the micromotions at the fracture site, bone strain, and implant stress were computed. Mean micromotions at the fracture surface and absolute and relative fracture surface with micromotions >150 µm were slightly lower with the short nail (8%, 3%, and 3%, respectively). The distal fracture extension negatively affected the stability, with increasing micromotions on the medial side. Bone strain above 1 % was not affected by the nail length. Fatigue stresses were similar for both implants, and no volume was found above the yield and ultimate stress in the tested conditions. This simulation study shows no benefit of long nails for the investigated patterns of reverse pertrochanteric fractures, with similar micromotions at the fracture site, bone strain, and implant stress.


Subject(s)
Bone Nails , Finite Element Analysis , Fracture Fixation, Intramedullary , Biomechanical Phenomena , Humans , Fracture Fixation, Intramedullary/instrumentation , Stress, Mechanical , Hip Fractures/surgery , Hip Fractures/physiopathology , Mechanical Phenomena
12.
J Orthop Trauma ; 38(10): 527-533, 2024 Oct 01.
Article in English | MEDLINE | ID: mdl-39325050

ABSTRACT

OBJECTIVES: To determine the association between postoperative enoxaparin use and the risk of requiring surgery for nonunion in patients treated with intramedullary nailing for midshaft fractures of the tibia. DESIGN: Retrospective cohort analysis. SETTING: Data were sourced from the PearlDiver national database. PATIENT SELECTION CRITERIA: Patients were identified through the PearlDiver database by using Current Procedural Terminology and International Classification of Diseases (ICD-10) codes. Included patients had undergone intramedullary nailing for midshaft fractures of the tibia between 2015 and 2020 and subsequently underwent revision surgery due to nonunion. OUTCOME MEASURES AND COMPARISONS: The primary outcome measured in this study was the rate of nonunion following intramedullary nailing for the different types of tibial shaft fractures (closed, Type I/II open, Type III open). For each fracture subtype, the study compared nonunion rates between those who received enoxaparin in the postoperative period and those who did not receive enoxaparin at any time during the first 6 weeks postoperatively. Factors such as the timing and duration of enoxaparin therapy and demographic variables were also considered. RESULTS: The study included 16,986 patients, average age was 49.2 years (SD 17.3); 43.1% were female. Five hundred four patients required revision surgery for nonunion (3.4%). Among patients who did not receive enoxaparin, the nonunion rates were 1.6%, 3.9%, and 6.9% for closed, Type I/II open, and Type III open fractures, respectively. For patients who received enoxaparin within the first 2 weeks, the nonunion rates were 2.6%, 4.7%, and 7.9% for closed (RR = 1.67, P < 0.0001), Type I/II open (RR = 1.21, P < 0.0001), and Type III open (RR = 1.17, P = 0.355) fractures, respectively. Logistic regression confirmed enoxaparin was independently associated with nonunion (odds ratios [OR] = 1.75, P = 0.0013 for closed fractures; OR = 1.51, P = 0.034 for Type I/II open fractures). Tobacco use was also a contributing factor (OR = 2.43, P < 0.0001 for closed fractures; OR = 2.00, P < 0.0001 for Type I/II open fractures; OR = 2.04, P = 0.0008 for Type III open fractures). CONCLUSIONS: The postoperative use of enoxaparin was associated with an elevated risk of nonunion in patients treated with intramedullary nailing for fractures of the tibial shaft. LEVEL OF EVIDENCE: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.


Subject(s)
Enoxaparin , Fracture Fixation, Intramedullary , Fractures, Ununited , Reoperation , Tibial Fractures , Humans , Tibial Fractures/surgery , Female , Male , Enoxaparin/therapeutic use , Middle Aged , Retrospective Studies , Reoperation/statistics & numerical data , Fracture Fixation, Intramedullary/adverse effects , Adult , Fractures, Ununited/epidemiology , Fractures, Ununited/surgery , Anticoagulants/therapeutic use , Aged , Cohort Studies
13.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(9): 1130-1137, 2024 Sep 15.
Article in Chinese | MEDLINE | ID: mdl-39300890

ABSTRACT

Objective: To review and summarize the projections of radiographic images during cephalomedullary nailing fixation for intertrochanteric femoral fractures, and to propose a set of three projections as standard requirement in immediate postoperative fluoroscopy. Methods: Papers on intertrochanteric femoral fractures treated with cephalomedullary nailing fixation that published in a three-year period of 2021-2023 in four leading English orthopedic trauma journals were searched in PubMed. The presented radiographic pictures were identified and scrutinized as whether they were in standard anteroposterior and/or lateral projections of the implanted nails. The nonstandard presence percentage was calculated. Combined with clinical experience, the standard anteroposterior and lateral perspective images of femoral neck, the current situation of radiographic imaging in the operation of cephalomedullary nails, the literature analysis of nonstandard images, the impact of limb rotation on image interpretation, and the characteristics of anteromedial 30° oblique perspective were summarized and analyzed. Results: The presence of nonstandard radiographic pictures is 32.1% in anteroposterior view and 69.2% in lateral view in leading orthopedic trauma journals. In cephalomedullary nailing fixation operation of intertrochanteric femoral fractures, it is reasonable to use the radiographic images of the implanted nails to represent the fractured head-neck, as the head-neck implant (lag screw or helical blade) is aimed to put into centrally in femoral head in lateral projection. Limb rotation or nonstandard projections produced distortion of images, which interfers the surgeons' judgement of fracture reduction quality and the measurement of implant position parameters in femoral head (such as neck-shaft angle and tip-apex distance), and finally lead to a meaningless comparison with the accurate normal value. The 30° anteromedial oblique view from the true lateral (set as 0°) is a tangential projection of the cortices at the anteromedial inferior corner, which gives a clear profile for the determination of cortical apposition status and mechanical support. It is essential to get firstly the true standard lateral fluoroscopy of the nail (shown as a line), then rotate the C-arm to 90° and 30° to get anteroposterior and anteromedial oblique views, and use these three immediate postoperative radiographies as the baseline for evaluation of operative quality and follow-up comparisons. Conclusion: As for real-time monitoring of surgical steps, intraoperative fluoroscopy follows the "Enough is Good" principle, but as for immediate postoperative data storage and basis for operative quality evaluation and baseline for follow-up comparison, it is recommended to obtain a set of three standard radiographic pictures in anteroposterior, true lateral, and 30° anteromedial oblique fluoroscopic projections.


Subject(s)
Bone Nails , Fracture Fixation, Intramedullary , Humans , Fracture Fixation, Intramedullary/methods , Fracture Fixation, Intramedullary/instrumentation , Hip Fractures/surgery , Hip Fractures/diagnostic imaging , Radiography/methods , Fluoroscopy/methods , Femoral Fractures/surgery , Femoral Fractures/diagnostic imaging
14.
Acta Orthop Traumatol Turc ; 58(4): 209-214, 2024 Aug 29.
Article in English | MEDLINE | ID: mdl-39320260

ABSTRACT

This study aimed to investigate the outcomes of Gamma3 nails fitted with U-blade lag screws in the management of combined neck and trochanter fracture of the femur. Two hundred-fifty patients with fractures in the proximal femur underwent treatment using Gamma3 nails integrated with U-blade lag screws from 2015 to 2022. Among these cases, 33 had combined neck and trochanteric fractures; 8 patients were excluded because of follow-up for <1 year. The remaining data of 25 patients (7 males and 18 females) were reviewed. Bone mineral density (BMD), body mass index (BMI), tip-apex distance (TAD), extent of lag screw migration, femoral neck-shaft angle, callus formation, fracture type, and treatment failure were analyzed. The mean patient age was 76.3 (range, 61-91) years, and the mean follow-up duration was 17.3 (range, 12.5-57.3) months. The mean BMD T-scores for the spine and femoral neck were -2.3 ± 1.0 and -2.8 ± 0.7, respectively; 18 patients had T-scores ≤-2.5, indicating osteoporosis. The mean BMI was 23.2 ± 3.8 kg/m2 , and the mean operative time was 69.8 (range, 45-90) minutes. Twenty-one patients experienced injuries from slipping, 2 sustained injuries from falling, and 2 from car traffic accidents. The mean TAD was 21.6 ± 5.9 mm, with 16 patients showing <25 mm. The mean extent of lag screw migration was 5.7 ± 5.1 mm. The mean femoral neck-shaft angle on plain radiographs was 125.1 ± 8.6 degrees immediately postoperatively and 120.3 ± 9.5 degrees at the final follow-up. During the follow-up period, the first callus formation was observed at 3.8 months (range, 1.4-7.3) on plain radiographs in the anteroposterior and axial views. Based on our fracture criteria, 4 patients had a two-part fracture type, 12 patients had three-part, and 9 patients had four-part. Out of 25 patients, 3 exhibited treatment failure. No significant differences were observed between the groups with and without bone union regarding age, BMD, BMI, operative time, TAD of the lag screw, extent of lag screw migration, and femoral neck-shaft angle. The bone union was achieved in 88% of patients who underwent treatment utilizing the U-blade Gamma3 nail for concomitant ipsilateral neck and trochanteric fractures. Level IV, Therapeutic Study.


Subject(s)
Bone Nails , Bone Screws , Femoral Neck Fractures , Fracture Fixation, Intramedullary , Hip Fractures , Humans , Male , Female , Aged , Hip Fractures/surgery , Hip Fractures/diagnostic imaging , Femoral Neck Fractures/surgery , Aged, 80 and over , Fracture Fixation, Intramedullary/methods , Fracture Fixation, Intramedullary/instrumentation , Middle Aged , Treatment Outcome , Retrospective Studies , Bone Density
16.
J Orthop Surg Res ; 19(1): 542, 2024 Sep 05.
Article in English | MEDLINE | ID: mdl-39238000

ABSTRACT

OBJECTIVE: The effectiveness and safety of fibular intramedullary nail fixation (FINF) compared to plate fixation (PF) in treating ankle fractures among adults remains unclear. Therefore, we conducted a meta-analysis to assess the efficacy and safety of FINF versus PF, aiming to provide orthopedic surgeons with valuable insights when choosing between the two internal fixation methods for patient treatment. METHODS: PubMed, EMBASE, and SCOPUS were systematically searched for articles comparing FINF and PF in ankle fractures among adults. Functional outcomes, complications, and bony union were compared between the implants. RESULTS: A total of seven studies were included in the study, involving 586 patients. The results revealed no statistically significant differences in functional outcomes between two groups at 3, 6, and 12 months postoperatively. The outcomes favoring FINF comprised a lower infection rate (RR = 0.23, 95%CI, 0.11 to 0.47, P < 0.0001). Conversely, the PF group exhibited a superior performance in terms of hardware failure rate (RR = 2.05, 95%CI, 1.16 to 3.60, P = 0.01). A statistically significant difference was observed in the results of hardware failure rate in the subgroup of studies conducted in Europe (RR = 2.74, 95%CI, 1.45 to 5.18, P = 0.002). Comparable findings were also noted in a subgroup of older adults (RR = 4.25, 95%CI, 1.57 to 11.50, P = 0.004). CONCLUSION: This systematic review suggests that FINF exhibits comparable effectiveness in the management of ankle fractures among adults, as compared to PF. Consequently, it is imperative to further delineate the surgical indications for both FINF and PF with precision to mitigate the risk of complications. Nevertheless, larger sample sizes and multi-center RCTs are imperative to corroborate this conclusion in the future.


Subject(s)
Ankle Fractures , Bone Nails , Bone Plates , Fracture Fixation, Intramedullary , Randomized Controlled Trials as Topic , Humans , Ankle Fractures/surgery , Fracture Fixation, Intramedullary/methods , Fracture Fixation, Intramedullary/instrumentation , Adult , Fibula/injuries , Fibula/surgery , Treatment Outcome
17.
BMC Musculoskelet Disord ; 25(1): 697, 2024 Sep 02.
Article in English | MEDLINE | ID: mdl-39223520

ABSTRACT

OBJECTIVE: There is currently a lack of in-depth comparative evaluation regarding the biomechanical properties of novel intramedullary nail devices in the treatment of basal femoral neck fractures (BFNF). This study aims to utilize finite element analysis to compare the performance differences of two novel devices with traditional PFNA and InterTan nails in the fixation of BFNF. METHODS: Based on a validated finite element model, this study constructed an accurate BFNF model and implanted four different intramedullary nail devices: PFNA, InterTan nail, PFBN (proximal femoral biomimetic nail), and NIS (novel intramedullary system). Under a vertical load of 2100N, the displacement and Von Mises stress (VMS) distribution of each group of models were evaluated through simulation testing. RESULTS: Under a load of 2100N, the PFBN device exhibited the best performance in terms of displacement and peak stress, while PFNA performed poorly. The peak displacement of the NIS device was lower than that of PFNA and InterTan nails, while the peak stress of the InterTan nail was lower than that of PFNA and NIS. CONCLUSION: The PFBN device demonstrates stronger load-bearing and shear-resistant properties in the treatment of BFNF, and the NIS device also shows significant improvement in stability. Therefore, both the PFBN and NIS devices are reliable internal fixation techniques for the treatment of CFIFs, with potential clinical application prospects.


Subject(s)
Bone Nails , Femoral Neck Fractures , Finite Element Analysis , Fracture Fixation, Intramedullary , Humans , Fracture Fixation, Intramedullary/instrumentation , Fracture Fixation, Intramedullary/methods , Femoral Neck Fractures/surgery , Femoral Neck Fractures/physiopathology , Biomechanical Phenomena/physiology , Stress, Mechanical , Weight-Bearing
18.
J Musculoskelet Neuronal Interact ; 24(3): 310-317, 2024 Sep 01.
Article in English | MEDLINE | ID: mdl-39219329

ABSTRACT

OBJECTIVES: To compare early outcomes of proximal femoral bionic nail (PFBN), Inter-TAN, proximal femoral nail antirotation (PFNA) for intertrochanteric fractures in elderly patients. METHODS: Eighty-two elderly patients with intertrochanteric femoral fractures treated at Xiangyang No. 1 People's Hospital affiliated with Hubei University of Medicine from December 2021 to 2022 were retrospectively analyzed. They were categorized into three surgical groups: PFBN (22 cases), Inter-TAN (20 cases), and PFNA (40 cases). Preoperative demographics and fracture characteristics were compared, alongside intraoperative and postoperative metrics like operative time and complication rates. RESULTS: In the PFBN group, operative time, fluoroscopy use, blood loss, and transfusion were higher, but postoperative weight-bearing, healing, and hospital stay were shorter compared to the Inter-TAN and PFNA groups (P<0.05). Inter-TAN had a significantly shorter postoperative weight-bearing time than PFNA (P<0.001). Other compared factors showed no significant differences between groups (P>0.05), including complication rates and scores at 6-month follow-up. CONCLUSIONS: PFBN, a novel surgical approach for intertrochanteric fractures in elderly patients, outperforms Inter-TAN and PFNA by accelerating early weight-bearing and hastening fracture recovery.


Subject(s)
Fracture Fixation, Intramedullary , Hip Fractures , Humans , Female , Fracture Fixation, Intramedullary/methods , Fracture Fixation, Intramedullary/adverse effects , Male , Aged , Hip Fractures/surgery , Retrospective Studies , Aged, 80 and over , Treatment Outcome , Bone Nails , Weight-Bearing/physiology , Postoperative Complications/epidemiology , Postoperative Complications/etiology
19.
Eur J Orthop Surg Traumatol ; 34(6): 3265-3273, 2024 Aug.
Article in English | MEDLINE | ID: mdl-39136728

ABSTRACT

PURPOSE: Malalignment of distal tibia fractures can lead to malunion/nonunion or alter the limb mechanical axis which may cause arthritis. Proposed methods to decrease malalignment include fibular fixation or multiplanar interlocking screws, however these remain controversial. This study aimed to identify factors associated with malalignment in distal tibial fractures with associated fibular shaft fractures. METHODS: A retrospective review was performed of distal tibia fractures with associated fibular shaft fractures treated with intramedullary nailing at two level one trauma centers between 2015 and 2019. Cases involving malalignment (> 5° of deviation from anatomic axis on either coronal/sagittal axis) on final follow-up (minimum three months postoperatively) were compared to those without malalignment with regard to demographics, fracture characteristics, intraoperative characteristics, and complications. RESULTS: The rate of malalignment was 13%. On multivariate analysis, multiplanar distal interlocking screw fixation (odds ratio [OR], 0.18; 95% confidence interval [CI] 0.03-0.92) was associated with a decreased rate of final malalignment, while nail diameter > 10 mm was associated with a higher rate (OR, 4.05; 95% CI 1.25-13.11). Fibular fixation was not associated with malalignment. CONCLUSION: Multiplanar distal interlocking screws may protect against malalignment. Fibula fixation does not appear associated with a decreased rate of malalignment in distal tibia fractures treated with intramedullary nails. LEVEL OF EVIDENCE: III.


Subject(s)
Bone Malalignment , Fibula , Fracture Fixation, Intramedullary , Tibial Fractures , Humans , Fracture Fixation, Intramedullary/adverse effects , Fracture Fixation, Intramedullary/instrumentation , Fracture Fixation, Intramedullary/methods , Tibial Fractures/surgery , Tibial Fractures/complications , Male , Female , Fibula/injuries , Fibula/surgery , Retrospective Studies , Bone Malalignment/etiology , Bone Malalignment/surgery , Middle Aged , Adult , Risk Factors , Bone Nails/adverse effects , Postoperative Complications/etiology , Bone Screws/adverse effects , Aged , Fibula Fractures
20.
Eur J Orthop Surg Traumatol ; 34(6): 2891-2902, 2024 Aug.
Article in English | MEDLINE | ID: mdl-39150553

ABSTRACT

BACKGROUND: Although segmental femoral shaft fractures (SFSF) are very challenging to manage, there has been no critical evaluation of the current practices and outcomes. The aim of this study is to evaluate their characteristics, management trends, outcomes, and complications. METHODS: A literature search was conducted via the SCOPUS, Embase (via SCOPUS) and MEDLINE (via PubMed) between 1995 and 2023. Studies were included if they reported patient demographics, mechanism of injury, classification of fractures, associated injuries, type of management, outcomes, and complications. EXCLUSION CRITERIA: only diaphyseal fractures were included and proximal and distal femoral fractures were excluded from this study. RESULTS: Overall, 22 studies met the inclusion criteria reporting on 313 patients. Mean age was 36.2 years with male-female ratio of 4.8 to 1. The majority were high-energy fractures secondary to road traffic accidents and 16% were open. The most commonly associated injuries included chest injury (27%) and lower leg fractures (24%). Treatment consisted of intramedullary nailing (IMN) (72%), plating (22%) or both combined (6%). Outcomes reported: good in 70%, fair in 10%, excellent in 19% and poor in 2% of cases. Mean time to union was 20 weeks. Complications are reported in 24% of cases, with most common delayed union (5%) and non-union (4%). CONCLUSION: SFSF are high-energy fractures occurring most commonly in young males, are open in 16% of cases and have significant associated injuries. In their overwhelming majority, IMN is the mainstay of treatment. The expected outcome is generally good in 70% of cases, although not devoid of complications in 24% of cases and patients must be aware of this during the consent process.


Subject(s)
Femoral Fractures , Fracture Fixation, Intramedullary , Postoperative Complications , Humans , Femoral Fractures/surgery , Postoperative Complications/etiology , Postoperative Complications/epidemiology , Fracture Fixation, Intramedullary/adverse effects , Fracture Fixation, Intramedullary/methods , Incidence , Male , Female , Bone Plates , Fractures, Open/surgery , Fractures, Open/complications , Treatment Outcome , Adult
SELECTION OF CITATIONS
SEARCH DETAIL