Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
Appl Radiat Isot ; 134: 112-116, 2018 Apr.
Article in English | MEDLINE | ID: mdl-29273465

ABSTRACT

The realization and dissemination of the 68Ga activity measurement unit in Cuba is presented. Firstly, the implementation of the Triple to Double Coincidence Ratio (TDCR) method is described for the calibration of the activity concentration of a 68Ga solution using a Hidex™ commercial liquid scintillation counter and a FORTRAN code developed for the calculation of the 68Ga counting efficiencies in the given measurement system. The relative expanded uncertainty (k = 2) associated with the 68Ga activity concentration obtained with the TDCR method is equal to 2%. With the aim to validate this measurement uncertainty estimate, the method is also applied to an Amersham standard solution of 22Na - a positron emitter with a similar decay mode to the 68Ga disintegration scheme from the point of view of type of emitted particles detected in the measurement system. The observed difference between the measured 22Na activity concentration by the TDCR method and the corresponding reference value traceable to NIST is equal to 0.16%. Outcomes of transferring the 68Ga activity standard, realized with the TDCR method, to the secondary standard radionuclide calibrator Capintec CRC™ 15R and to three radionuclide calibrators used for 68Ga PET applications in a hospital are also shown.


Subject(s)
Gallium Radioisotopes/analysis , Nuclear Medicine Department, Hospital , Calibration , Cuba , Gallium Radioisotopes/standards , Reference Standards , Reproducibility of Results , Uncertainty
2.
Appl Radiat Isot ; 64(10-11): 1225-8, 2006.
Article in English | MEDLINE | ID: mdl-16556502

ABSTRACT

The activity of 72Ga sources produced by irradiation at the IEA-R1 reactor have been performed in a 4pibeta-gamma coincidence system by using the extrapolation technique. The measurements were undertaken selecting two windows in the gamma-channel, in order to check the consistency of the results. A Monte Carlo calculation was performed in order to predict the behavior of the observed activity as a function of the 4pibeta detector efficiency and the results were compared to experimental values.


Subject(s)
Algorithms , Gallium Radioisotopes/analysis , Gallium Radioisotopes/standards , Scintillation Counting/standards , Spectrometry, Gamma/standards , Brazil , Guidelines as Topic , Radiation Dosage , Reference Standards , Reference Values , Reproducibility of Results , Scintillation Counting/methods , Sensitivity and Specificity , Spectrometry, Gamma/methods
SELECTION OF CITATIONS
SEARCH DETAIL