Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 25.569
1.
Interv Cardiol Clin ; 13(3): 333-341, 2024 Jul.
Article En | MEDLINE | ID: mdl-38839167

The surgical pulmonary artery band was first introduced in 1952 and, to this day, can produce challenges in regard to the ideal amount of restriction and the need for reoperations. A transcatheter option may be the ideal solution as it allows for a less-invasive approach for a better hemodynamic assessment and easier re-intervention. To date, multiple approaches have been developed with device modifications to create restrictions to flow, each with advantages and limitations. Continued experience is still necessary to determine the ideal device to use to create an adequate and modifiable level of restriction.


Heart Defects, Congenital , Pulmonary Artery , Humans , Heart Defects, Congenital/surgery , Heart Defects, Congenital/physiopathology , Pulmonary Artery/surgery , Cardiac Catheterization/methods , Hemodynamics/physiology , Equipment Design
3.
BMC Anesthesiol ; 24(1): 201, 2024 Jun 06.
Article En | MEDLINE | ID: mdl-38844869

BACKGROUND: Significant hemodynamic changes occur during liver transplantation, emphasizing the importance of precious and continuous monitoring of cardiac output, cardiac index, and other parameters. Although the monitoring of cardiac output by pulse indicator continuous cardiac output (PiCCO) was statistically homogeneous compared to the clinical gold standard pulmonary artery catheterization (PAC) in previous studies of liver transplantation, there are fewer statistical methods for the assessment of its conclusions, and a lack of comparisons of other hemodynamic parameters (e.g., SVRI, systemic vascular resistance index). Some studies have also concluded that the agreement between PiCCO and PAC is not good enough. Overall, there are no uniform conclusions regarding the agreement between PiCCO and PAC in previous studies. This study evaluates the agreement and trending ability of relevant hemodynamic parameters obtained with PiCCO compared to the clinical gold standard PAC from multiple perspectives, employing various statistical methods. METHODS: Fifty-two liver transplantation patients were included. Cardiac output (CO), cardiac index (CI), SVRI and stroke volume index (SVI) values were monitored at eight time points using both PiCCO and PAC. The results were analyzed by Bland-Altman analysis, Passing-bablok regression, intra-class correlation coefficient (ICC), 4-quadrant plot, polar plot, and trend interchangeability method (TIM). RESULTS: The Bland-Altman analysis revealed high percentage errors for PiCCO: 54.06% for CO, 52.70% for CI, 62.18% for SVRI, and 51.97% for SVI, indicating poor accuracy. While Passing-Bablok plots showed favorable agreement for SVRI overall and during various phases, the agreement for other parameters was less satisfactory. The ICC results confirmed good overall agreement between the two devices across most parameters, except for SVRI during the new liver phase, which showed poor agreement. Additionally, four-quadrant and polar plot analyses indicated that all agreement rate values fell below the clinically acceptable threshold of over 90%, and all angular deviation values exceeded ± 5°, demonstrating that PiCCO is unable to meet the acceptable trends. Using the TIM, the interchangeability rates were found to be quite low: 20% for CO and CI, 16% for SVRI, and 13% for SVI. CONCLUSIONS: Our study revealed notable disparities in absolute values of CO, CI, SVRI and SVI between PiCCO and PAC in intraoperative liver transplant settings, notably during the neohepatic phase where errors were particularly pronounced. Consequently, these findings highlight the need for careful consideration of PiCCO's advantages and disadvantages in liver transplantation scenarios, including its multiple parameters (such as the encompassing extravascular lung water index), against its limited correlation with PAC.


Cardiac Output , Catheterization, Swan-Ganz , Hemodynamics , Liver Transplantation , Monitoring, Intraoperative , Liver Transplantation/methods , Humans , Catheterization, Swan-Ganz/methods , Cardiac Output/physiology , Male , Middle Aged , Female , Hemodynamics/physiology , Monitoring, Intraoperative/methods , Aged , Adult , Pulmonary Artery/physiology
4.
Clin Cardiol ; 47(6): e24277, 2024 Jun.
Article En | MEDLINE | ID: mdl-38838029

BACKGROUND: Invasive hemodynamics are fundamental in assessing patients with advanced heart failure (HF). Several novel hemodynamic parameters have been studied; however, the relative prognostic potential remains ill-defined. HYPOTHESIS: Advanced hemodynamic parameters provide additional prognostication beyond the standard hemodynamic assessment. METHODS: Patients from the PRognostic Evaluation During Invasive CaTheterization for Heart Failure (PREDICT-HF) registry who underwent right heart catheterization (RHC) were included in the analysis. The primary endpoint was survival to orthotopic heart transplant (OHT) or durable left ventricular assist device (LVAD), or death within 6 months of RHC. RESULTS: Of 846 patients included, 176 (21%) met the primary endpoint. In a multivariate model that included traditional hemodynamic variables, pulmonary capillary wedge pressure (PCWP) (OR: 1.10, 1.04-1.15, p < .001), and cardiac index (CI) (OR: 0.86, 0.81-0.92, p < .001) were shown to be predictive of adverse outcomes. In a separate multivariate model that incorporated advanced hemodynamic parameters, cardiac power output (CPO) (OR: 0.76, 0.71-0.83, p < .001), aortic pulsatility index (API) (OR: 0.94, 0.91-0.96, p < .001), and pulmonary artery pulsatility index (OR: 1.02, 1.00-1.03, p .027) were all significantly associated with the primary outcome. Positively concordant API and CPO afforded the best freedom from the endpoint (94.7%), whilst negatively concordant API and CPO had the worst freedom from the endpoint (61.5%, p < .001). Those with discordant API and CPO had similar freedom from the endpoint. CONCLUSION: The advanced hemodynamic parameters API and CPO are independently associated with death or the need for OHT or LVAD within 6 months. Further prospective studies are needed to validate these parameters and elucidate their role in patients with advanced HF.


Cardiac Catheterization , Heart Failure , Hemodynamics , Registries , Humans , Heart Failure/physiopathology , Heart Failure/diagnosis , Heart Failure/therapy , Heart Failure/mortality , Male , Female , Middle Aged , Hemodynamics/physiology , Risk Assessment/methods , Prognosis , Aged , Risk Factors , Pulmonary Wedge Pressure/physiology , Heart-Assist Devices , Heart Transplantation , Retrospective Studies , United States/epidemiology , Time Factors , Predictive Value of Tests , Ventricular Function, Left/physiology
6.
PLoS One ; 19(5): e0302828, 2024.
Article En | MEDLINE | ID: mdl-38722930

Cupping therapy is a popular intervention for improving muscle recovery after exercise although clinical evidence is weak. Previous studies demonstrated that cupping therapy may improve microcirculation of the soft tissue to accelerate tissue healing. However, it is unclear whether the cupping size could affect the spatial hemodynamic response of the treated muscle. The objective of this study was to use 8-channel near-infrared spectroscopy to assess this clinical question by assessing the effect of 3 cupping sizes (35, 40, and 45 mm in inner diameter of the circular cup) under -300 mmHg for 5 min on the muscle hemodynamic response from the area inside and outside the cup, including oxyhemoglobin and deoxy-hemoglobin in 18 healthy adults. Two-way factorial design was used to assess the interaction between the cupping size (35, 40, and 45 mm) and the location (inside and outside the cup) and the main effects of the cupping size and the location. The two-way repeated measures ANOVA demonstrated an interaction between the cupping size and the location in deoxy-hemoglobin (P = 0.039) but no interaction in oxyhemoglobin (P = 0.100), and a main effect of the cup size (P = 0.001) and location (P = 0.023) factors in oxyhemoglobin. For the cupping size factor, the 45-mm cup resulted in a significant increase in oxyhemoglobin (5.738±0.760 µM) compared to the 40-mm (2.095±0.312 µM, P<0.001) and 35-mm (3.134±0.515 µM, P<0.01) cup. Our findings demonstrate that the cupping size and location factors affect the muscle hemodynamic response, and the use of multi-channel near-infrared spectroscopy may help understand benefits of cupping therapy on managing musculoskeletal impairment.


Hemodynamics , Muscle, Skeletal , Oxyhemoglobins , Spectroscopy, Near-Infrared , Humans , Spectroscopy, Near-Infrared/methods , Male , Hemodynamics/physiology , Female , Adult , Muscle, Skeletal/physiology , Muscle, Skeletal/blood supply , Oxyhemoglobins/metabolism , Oxyhemoglobins/analysis , Cupping Therapy/methods , Young Adult , Hemoglobins/metabolism
7.
J Biomed Opt ; 29(Suppl 3): S33302, 2024 Jun.
Article En | MEDLINE | ID: mdl-38707651

Significance: Cerebral oximeters have the potential to detect abnormal cerebral blood oxygenation to allow for early intervention. However, current commercial systems have two major limitations: (1) spatial coverage of only the frontal region, assuming that surgery-related hemodynamic effects are global and (2) susceptibility to extracerebral signal contamination inherent to continuous-wave near-infrared spectroscopy (NIRS). Aim: This work aimed to assess the feasibility of a high-density, time-resolved (tr) NIRS device (Kernel Flow) to monitor regional oxygenation changes across the cerebral cortex during surgery. Approach: The Flow system was assessed using two protocols. First, digital carotid compression was applied to healthy volunteers to cause a rapid oxygenation decrease across the ipsilateral hemisphere without affecting the contralateral side. Next, the system was used on patients undergoing shoulder surgery to provide continuous monitoring of cerebral oxygenation. In both protocols, the improved depth sensitivity of trNIRS was investigated by applying moment analysis. A dynamic wavelet filtering approach was also developed to remove observed temperature-induced signal drifts. Results: In the first protocol (28±5 years; five females, five males), hair significantly impacted regional sensitivity; however, the enhanced depth sensitivity of trNIRS was able to separate brain and scalp responses in the frontal region. Regional sensitivity was improved in the clinical study given the age-related reduction in hair density of the patients (65±15 years; 14 females, 13 males). In five patients who received phenylephrine to treat hypotension, different scalp and brain oxygenation responses were apparent, although no regional differences were observed. Conclusions: The Kernel Flow has promise as an intraoperative neuromonitoring device. Although regional sensitivity was affected by hair color and density, enhanced depth sensitivity of trNIRS was able to resolve differences in scalp and brain oxygenation responses in both protocols.


Cerebrovascular Circulation , Spectroscopy, Near-Infrared , Humans , Spectroscopy, Near-Infrared/methods , Spectroscopy, Near-Infrared/instrumentation , Female , Male , Adult , Cerebrovascular Circulation/physiology , Hemodynamics/physiology , Oximetry/methods , Oximetry/instrumentation , Oxygen/blood , Oxygen/metabolism , Brain/diagnostic imaging , Brain/blood supply , Equipment Design
8.
Andes Pediatr ; 95(2): 202-212, 2024 Apr.
Article Es | MEDLINE | ID: mdl-38801369

Sepsis is one of the main causes of admission to Intensive Care Units (ICU). The hemodynamic objectives usually sought during the resuscitation of the patient in septic shock correspond to macrohemodynamic parameters (heart rate, blood pressure, central venous pressure). However, persistent alterations in microcirculation, despite the restoration of macrohemodynamic parameters, can cause organ failure. This dissociation between the macrocirculation and microcirculation originates the need to evaluate organ tissue perfusion, the most commonly used being urinary output, lactatemia, central venous oxygen saturation (ScvO2), and veno-arterial pCO2 gap. Because peripheral tissues, such as the skin, are sensitive to disturbances in perfusion, noninvasive monitoring of peripheral circulation, such as skin temperature gradient, capillary refill time, mottling score, and peripheral perfusion index may be helpful as early markers of the existence of systemic hemodynamic alterations. Peripheral circulation monitoring techniques are relatively easy to interpret and can be used directly at the patient's bedside. This approach can be quickly applied in the intra- or extra-ICU setting. The objective of this narrative review is to analyze the various existing tissue perfusion markers and to update the evidence that allows guiding hemodynamic support in a more individualized therapy for each patient.


Hemodynamics , Microcirculation , Humans , Child , Microcirculation/physiology , Hemodynamics/physiology , Shock, Septic/therapy , Shock, Septic/physiopathology , Shock, Septic/diagnosis , Monitoring, Physiologic/methods , Hemodynamic Monitoring/methods , Acute Disease , Sepsis/diagnosis , Sepsis/therapy , Sepsis/physiopathology , Biomarkers/blood
10.
Sensors (Basel) ; 24(9)2024 May 03.
Article En | MEDLINE | ID: mdl-38733027

Heart failure (HF) is a complex clinical syndrome associated with significant morbidity, mortality, and healthcare costs. It is characterized by various structural and/or functional abnormalities of the heart, resulting in elevated intracardiac pressure and/or inadequate cardiac output at rest and/or during exercise. These dysfunctions can originate from a variety of conditions, including coronary artery disease, hypertension, cardiomyopathies, heart valve disorders, arrhythmias, and other lifestyle or systemic factors. Identifying the underlying cause is crucial for detecting reversible or treatable forms of HF. Recent epidemiological studies indicate that there has not been an increase in the incidence of the disease. Instead, patients seem to experience a chronic trajectory marked by frequent hospitalizations and stagnant mortality rates. Managing these patients requires a multidisciplinary approach that focuses on preventing disease progression, controlling symptoms, and preventing acute decompensations. In the outpatient setting, patient self-care plays a vital role in achieving these goals. This involves implementing necessary lifestyle changes and promptly recognizing symptoms/signs such as dyspnea, lower limb edema, or unexpected weight gain over a few days, to alert the healthcare team for evaluation of medication adjustments. Traditional methods of HF monitoring, such as symptom assessment and periodic clinic visits, may not capture subtle changes in hemodynamics. Sensor-based technologies offer a promising solution for remote monitoring of HF patients, enabling early detection of fluid overload and optimization of medical therapy. In this review, we provide an overview of the CardioMEMS device, a novel sensor-based system for pulmonary artery pressure monitoring in HF patients. We discuss the technical aspects, clinical evidence, and future directions of CardioMEMS in HF management.


Heart Failure , Humans , Heart Failure/therapy , Heart Failure/physiopathology , Cardiology/methods , Monitoring, Physiologic/methods , Monitoring, Physiologic/instrumentation , Disease Management , Hemodynamics/physiology
11.
Khirurgiia (Mosk) ; (5): 95-100, 2024.
Article Ru | MEDLINE | ID: mdl-38785244

A personalized approach with attention to anamnesis and specific symptoms is necessary in patients with internal carotid artery tortuosity. Neuroimaging (especially before elective surgery) or functional stress tests following ultrasound of supra-aortic vessels may be necessary depending on medical history and complaints. In addition to standard Doppler ultrasound, these patients should undergo rotational and orthostatic transformation tests. We analyze changes in shape and hemodynamic parameters within the tortuosity area in various body positions. This is especially valuable for patients with concomitant carotid artery stenosis. The article presents a clinical case illustrating the importance of such approach.


Carotid Artery, Internal , Carotid Stenosis , Humans , Carotid Artery, Internal/diagnostic imaging , Carotid Artery, Internal/abnormalities , Carotid Artery, Internal/physiopathology , Carotid Stenosis/physiopathology , Carotid Stenosis/complications , Carotid Stenosis/diagnosis , Carotid Stenosis/surgery , Male , Female , Middle Aged , Ultrasonography, Doppler/methods , Hemodynamics/physiology , Atherosclerosis/complications , Atherosclerosis/diagnosis , Atherosclerosis/physiopathology , Vascular Malformations/diagnosis , Vascular Malformations/complications , Vascular Malformations/physiopathology , Aged , Arteries/abnormalities , Joint Instability , Skin Diseases, Genetic
12.
J Biomech ; 168: 112124, 2024 May.
Article En | MEDLINE | ID: mdl-38701696

Congenital arterial stenosis such as supravalvar aortic stenosis (SVAS) are highly prevalent in Williams syndrome (WS) and other arteriopathies pose a substantial health risk. Conventional tools for severity assessment, including clinical findings and pressure gradient estimations, often fall short due to their susceptibility to transient physiological changes and disease stage influences. Moreover, in the pediatric population, the severity of these and other congenital heart defects (CHDs) often restricts the applicability of invasive techniques for obtaining crucial physiological data. Conversely, evaluating CHDs and their progression requires a comprehensive understanding of intracardiac blood flow. Current imaging modalities, such as blood speckle imaging (BSI) and four-dimensional magnetic resonance imaging (4D MRI) face limitations in resolving flow data, especially in cases of elevated flow velocities. To address these challenges, we devised a computational framework employing zero-dimensional (0D) lumped parameter models coupled with patient-specific reconstructed geometries pre- and post-surgical intervention to execute computational fluid dynamic (CFD) simulations. This framework facilitates the analysis and visualization of intricate blood flow patterns, offering insights into geometry and flow dynamics alterations impacting cardiac function. In this study, we aim to assess the efficacy of surgical intervention in correcting an extreme aortic defect in a patient with WS, leading to reductions in wall shear stress (WSS), maximum velocity magnitude, pressure drop, and ultimately a decrease in cardiac workload.


Hemodynamics , Models, Cardiovascular , Williams Syndrome , Humans , Williams Syndrome/physiopathology , Williams Syndrome/diagnostic imaging , Hemodynamics/physiology , Heart Defects, Congenital/physiopathology , Heart Defects, Congenital/complications , Heart Defects, Congenital/diagnostic imaging , Aorta/physiopathology , Aorta/diagnostic imaging , Blood Flow Velocity/physiology , Male , Female , Computer Simulation
13.
Eur J Cardiothorac Surg ; 65(5)2024 May 03.
Article En | MEDLINE | ID: mdl-38710669

OBJECTIVES: The objective of this analysis was to assess the normal haemodynamic performance of contemporary surgical aortic valves at 1 year postimplant in patients undergoing surgical aortic valve replacement for significant valvular dysfunction. By pooling data from 4 multicentre studies, this study will contribute to a better understanding of the effectiveness of surgical aortic valve replacement procedures, aiding clinicians and researchers in making informed decisions regarding valve selection and patient management. METHODS: Echocardiograms were assessed by a single core laboratory. Effective orifice area, dimensionless velocity index, mean aortic gradient, peak aortic velocity and stroke volume were evaluated. RESULTS: The cohort included 2958 patients. Baseline age in the studies ranged from 70.1 ± 9.0 to 83.3 ± 6.4 years, and Society of Thoracic Surgeons risk of mortality was 1.9 ± 0.7 to 7.5 ± 3.4%. Twenty patients who had received a valve model implanted in fewer than 10 cases were excluded. Ten valve models (all tissue valves; n = 2938 patients) were analysed. At 1 year, population mean effective orifice area ranged from 1.46 ± 0.34 to 2.12 ± 0.59 cm2, and dimensionless velocity index, from 0.39 ± 0.07 to 0.56 ± 0.15. The mean gradient ranged from 8.6 ± 3.4 to 16.1 ± 6.2 mmHg with peak aortic velocity of 1.96 ± 0.39 to 2.65 ± 0.47 m/s. Stroke volume was 75.3 ± 19.6 to 89.8 ± 24.3 ml. CONCLUSIONS: This pooled cohort is the largest to date of contemporary surgical aortic valves with echocardiograms analysed by a single core lab. Overall haemodynamic performance at 1 year ranged from good to excellent. These data can serve as a benchmark for other studies and may be useful to evaluate the performance of bioprosthetic surgical valves over time. CLINICAL TRIAL REGISTRATION NUMBER: NCT02088554, NCT02701283, NCT01586910 and NCT01531374.


Aortic Valve , Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Hemodynamics , Humans , Hemodynamics/physiology , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aged , Female , Male , Aged, 80 and over , Heart Valve Prosthesis Implantation/methods , Echocardiography , Middle Aged , Prosthesis Design
14.
Sci Rep ; 14(1): 10242, 2024 05 03.
Article En | MEDLINE | ID: mdl-38702415

Cerebral infra-slow oscillation (ISO) is a source of vasomotion in endogenic (E; 0.005-0.02 Hz), neurogenic (N; 0.02-0.04 Hz), and myogenic (M; 0.04-0.2 Hz) frequency bands. In this study, we quantified changes in prefrontal concentrations of oxygenated hemoglobin (Δ[HbO]) and redox-state cytochrome c oxidase (Δ[CCO]) as hemodynamic and metabolic activity metrics, and electroencephalogram (EEG) powers as electrophysiological activity, using concurrent measurements of 2-channel broadband near-infrared spectroscopy and EEG on the forehead of 22 healthy participants at rest. After preprocessing, the multi-modality signals were analyzed using generalized partial directed coherence to construct unilateral neurophysiological networks among the three neurophysiological metrics (with simplified symbols of HbO, CCO, and EEG) in each E/N/M frequency band. The links in these networks represent neurovascular, neurometabolic, and metabolicvascular coupling (NVC, NMC, and MVC). The results illustrate that the demand for oxygen by neuronal activity and metabolism (EEG and CCO) drives the hemodynamic supply (HbO) in all E/N/M bands in the resting prefrontal cortex. Furthermore, to investigate the effect of transcranial photobiomodulation (tPBM), we performed a sham-controlled study by delivering an 800-nm laser beam to the left and right prefrontal cortex of the same participants. After performing the same data processing and statistical analysis, we obtained novel and important findings: tPBM delivered on either side of the prefrontal cortex triggered the alteration or reversal of directed network couplings among the three neurophysiological entities (i.e., HbO, CCO, and EEG frequency-specific powers) in the physiological network in the E and N bands, demonstrating that during the post-tPBM period, both metabolism and hemodynamic supply drive electrophysiological activity in directed network coupling of the prefrontal cortex (PFC). Overall, this study revealed that tPBM facilitates significant modulation of the directionality of neurophysiological networks in electrophysiological, metabolic, and hemodynamic activities.


Electroencephalography , Prefrontal Cortex , Spectroscopy, Near-Infrared , Humans , Prefrontal Cortex/physiology , Prefrontal Cortex/metabolism , Male , Adult , Female , Spectroscopy, Near-Infrared/methods , Low-Level Light Therapy/methods , Young Adult , Rest/physiology , Oxyhemoglobins/metabolism , Electron Transport Complex IV/metabolism , Hemodynamics/physiology , Nerve Net/physiology , Nerve Net/metabolism
15.
Physiol Behav ; 281: 114574, 2024 Jul 01.
Article En | MEDLINE | ID: mdl-38697274

Postural change from supine or sitting to standing up leads to displacement of 300 to 1000 mL of blood from the central parts of the body to the lower limb, which causes a decrease in venous return to the heart, hence decrease in cardiac output, causing a drop in blood pressure. This may lead to falling down, syncope, and in general reducing the quality of daily activities, especially in the elderly and anyone suffering from nervous system disorders such as Parkinson's or orthostatic hypotension (OH). Among different modalities to study brain function, functional near-infrared spectroscopy (fNIRS) is a neuroimaging method that optically measures the hemodynamic response in brain tissue. Concentration changes in oxygenated hemoglobin (HbO2) and deoxygenated hemoglobin (HHb) are associated with brain neural activity. fNIRS is significantly more tolerant to motion artifacts compared to fMRI, PET, and EEG. At the same time, it is portable, has a simple structure and usage, is safer, and much more economical. In this article, we systematically reviewed the literature to examine the history of using fNIRS in monitoring brain oxygenation changes caused by sudden changes in body position and its relationship with the blood pressure changes. First, the theory behind brain hemodynamics monitoring using fNIRS and its advantages and disadvantages are presented. Then, a study of blood pressure variations as a result of postural changes using fNIRS is described. It is observed that only 58 % of the references concluded a positive correlation between brain oxygenation changes and blood pressure changes. At the same time, 3 % showed a negative correlation, and 39 % did not show any correlation between them.


Blood Pressure , Brain , Hemodynamics , Posture , Spectroscopy, Near-Infrared , Humans , Brain/diagnostic imaging , Brain/blood supply , Brain/metabolism , Blood Pressure/physiology , Posture/physiology , Hemodynamics/physiology
16.
Comput Biol Med ; 176: 108526, 2024 Jun.
Article En | MEDLINE | ID: mdl-38749328

Aortic valve replacement has become an increasing concern due to the rising prevalence of aortic stenosis in an ageing population. Existing replacement options have limitations, necessitating the development of improved prosthetic aortic valves. In this study, flow characteristics during systole in a stenotic aortic valve case are compared with those downstream of two newly designed surgical bioprosthetic aortic valves (BioAVs). To do so, advanced three-dimensional fluid-structure interaction simulations are conducted and dedicated analysis methods to investigate jet flow configuration and vortex dynamics are developed. Our findings reveal that the stenotic case maintains a high jet flow eccentricity due to a fixed orifice geometry, resulting in flow separation and increased vortex stretching and tilting in the commissural low-flow regions. One BioAV design introduces non-axisymmetric leaflet motion, which reduces the maximum jet velocity and forms more vortical structures. The other BioAV design produces a fixed symmetric triangular jet shape due to non-moving leaflets and exhibits favourable vorticity attenuation, revealed by negative temporally and spatially averaged projected vortex stretching values, and significantly reduced drag. Therefore, this study highlights the benefits of custom-designed aortic valves in the context of their replacement through comprehensive and novel flow analyses. The results emphasise the importance of analysing jet flow, vortical structures, momentum balance and vorticity transport for thoroughly evaluating aortic valve performance.


Aortic Valve , Heart Valve Prosthesis , Hemodynamics , Models, Cardiovascular , Humans , Aortic Valve/physiopathology , Aortic Valve/surgery , Aortic Valve/physiology , Hemodynamics/physiology , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Blood Flow Velocity , Bioprosthesis
17.
Comput Biol Med ; 176: 108552, 2024 Jun.
Article En | MEDLINE | ID: mdl-38754219

Severe aortic valve stenosis can lead to heart failure and aortic valve replacement (AVR) is the primary treatment. However, increasing prevalence of aortic stenosis cases reveal limitations in current replacement options, necessitating improved prosthetic aortic valves. We investigate flow disturbances downstream of severe aortic stenosis and two bioprosthetic aortic valve (BioAV) designs using advanced energy-based analyses. Three-dimensional high-fidelity fluid-structure interaction simulations have been conducted and a dedicated and novel spectral analysis has been developed to characterise the kinetic energy (KE) carried by eddies in the wavenumber space. In addition, new field quantities, i.e. modal KE anisotropy intensity as well as normalised helicity intensity, are introduced. Spectral analysis shows kinetic energy (KE) decay variations, with the stenotic case aligning with Kolmogorov's theory, while BioAV cases differing. We explore the impact of flow helicity on KE transfer and decay in BioAVs. Probability distributions of modal KE anisotropy unveil flow asymmetries in the stenotic and one BioAV cases. Moreover, an inverse correlation between temporally averaged modal KE anisotropy and normalised instantaneous helicity intensity is noted, with the coefficient of determination varying among the valve configurations. Leaflet dynamics analysis highlights a stronger correlation between flow and biomechanical KE anisotropy in one BioAV due to higher leaflet displacement magnitude. These findings emphasise the role of valve architecture in aortic turbulence as well as its importance for BioAV performance and energy-based design enhancement.


Aortic Valve Stenosis , Aortic Valve , Heart Valve Prosthesis , Hemodynamics , Models, Cardiovascular , Humans , Aortic Valve/physiopathology , Aortic Valve/surgery , Anisotropy , Hemodynamics/physiology , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging
18.
Comput Biol Med ; 176: 108563, 2024 Jun.
Article En | MEDLINE | ID: mdl-38761498

Boundary conditions (BCs) is one pivotal factor influencing the accuracy of hemodynamic predictions on intracranial aneurysms (IAs) using computational fluid dynamics (CFD) modeling. Unfortunately, a standard procedure to secure accurate BCs for hemodynamic modeling does not exist. To bridge such a knowledge gap, two representative patient-specific IA models (Case-I and Case-II) were reconstructed and their blood flow velocity waveforms in the internal carotid artery (ICA) were measured by ultrasonic techniques and modeled by discrete Fourier transform (DFT). Then, numerical investigations were conducted to explore the appropriate number of samples (N) for DFT modeling to secure the accurate BC by comparing a series of hemodynamic parameters using in-vitro validated CFD modeling. Subsequently, a comprehensive comparison in hemodynamic characteristics under patient-specific BCs and a generalized BC based on a one-dimensional (1D) model was conducted to reinforce the understanding that a patient-specific BC is pivotal for accurate hemodynamic risk evaluations on IA pathophysiology. In addition, the influence of the variance of heart rate/cardiac pulsatile period on hemodynamic characteristics in IA models was studied preliminarily. The results showed that N ≥ 16 for DFT model is a decent choice to secure the proper BC profile to calculate time-averaged hemodynamic parameters, while more data points such as N ≥ 36 can ensure the accuracy of instantaneous hemodynamic predictions. In addition, results revealed the generalized BC could overestimate or underestimate the hemodynamic risks on IAs significantly; thus, patient-specific BCs are highly recommended for hemodynamic modeling for IA risk evaluation. Furthermore, this study discovered the variance of heart rate has rare influences on hemodynamic characteristics in both instantaneous and time-averaged parameters under the assumption of an identical blood flow rate.


Hemodynamics , Intracranial Aneurysm , Models, Cardiovascular , Intracranial Aneurysm/physiopathology , Intracranial Aneurysm/diagnostic imaging , Humans , Hemodynamics/physiology , Blood Flow Velocity/physiology , Ultrasonography/methods , Male , Carotid Artery, Internal/physiopathology , Carotid Artery, Internal/diagnostic imaging , Cerebrovascular Circulation/physiology , Fourier Analysis , Computer Simulation , Female
19.
Comput Biol Med ; 176: 108604, 2024 Jun.
Article En | MEDLINE | ID: mdl-38761502

OBJECTIVE: In young patients, aortic valve disease is often treated by placement of a pulmonary autograft (PA) which adapts to its new environment through growth and remodeling. To better understand the hemodynamic forces acting on the highly distensible PA in the acute phase after surgery, we developed a fluid-structure interaction (FSI) framework and comprehensively compared hemodynamics and wall shear-stress (WSS) metrics with a computational fluid dynamic (CFD) simulation. METHODS: The FSI framework couples a prestressed non-linear hyperelastic arterial tissue model with a fluid model using the in-house coupling code CoCoNuT. Geometry, material parameters and boundary conditions are based on in-vivo measurements. Hemodynamics, time-averaged WSS (TAWSS), oscillatory shear index (OSI) and topological shear variation index (TSVI) are evaluated qualitatively and quantitatively for 3 different sheeps. RESULTS: Despite systolic-to-diastolic volumetric changes of the PA in the order of 20 %, the point-by-point correlation of TAWSS and OSI obtained through CFD and FSI remains high (r > 0.9, p < 0.01) for TAWSS and (r > 0.8, p < 0.01) for OSI). Instantaneous WSS divergence patterns qualitatively preserve similarities, but large deformations of the PA leads to a decrease of the correlation between FSI and CFD resolved TSVI (r < 0.7, p < 0.01). Moderate co-localization between FSI and CFD is observed for low thresholds of TAWSS and high thresholds of OSI and TSVI. CONCLUSION: FSI might be warranted if we were to use the TSVI as a mechano-biological driver for growth and remodeling of PA due to varying intra-vascular flow structures and near wall hemodynamics because of the large expansion of the PA.


Hemodynamics , Models, Cardiovascular , Pulmonary Artery , Hemodynamics/physiology , Pulmonary Artery/physiology , Pulmonary Artery/physiopathology , Hydrodynamics , Animals , Humans , Computer Simulation , Pulmonary Valve/surgery , Pulmonary Valve/physiology , Autografts , Stress, Mechanical
20.
Aerosp Med Hum Perform ; 95(6): 297-304, 2024 Jun 01.
Article En | MEDLINE | ID: mdl-38790119

INTRODUCTION: Negative pressure breathing is breathing with decreased pressure in the respiratory tract without lowering pressure acting on the torso. We lowered air pressure only during inspiration (NPBin). NPBin, used to increase venous return to the heart, is considered a countermeasure against redistribution of body fluids toward the head during spaceflight. We studied NPBin effects on circulation in healthy humans with an emphasis on NPBin-induced oscillations of hemodynamic parameters synchronous with breathing. We propose an approach to analyze the oscillations based on coherent averaging.METHODS: Eight men ages 24-42 yr participated in the NPBin and control series. During the series, to reproduce fluids shift observed under microgravity, subjects were supine and head down (-8°). Duration of NPBin was 20 min, rarefaction -20 cm H2O. Hemodynamic parameters were measured by Finometer. Electrical impedance measurements were used to estimate changes in blood filling of cerebral vessels.RESULTS: Mean values of hemodynamic parameters virtually did not change under NPBin, but NPBin induced oscillations of the parameters synchronous with respiration. Peak-to-peak amplitude under NPBin were: mean arterial pressure, 4 ± 1 (mmHg); stroke volume, 7 ± 3 (mL); and heart rate, 4 ± 1 (bpm). Electrical impedance of the head increased during inspiration. The increase under NPBin was three times greater than under normal breathing.DISCUSSION: Analysis of oscillations gives more information than analysis of mean values. NPBin induces short-term decrease in left ventricle stroke volume and arterial blood pressure during each inspiration; the decrease is compensated by increase after inspiration. NPBin facilitates redistribution of body fluids away from the head.Semenov YS, Melnikov IS, Luzhnov PV, Dyachenko AI. Oscillations of hemodynamic parameters induced by negative pressure breathing in healthy humans. Aerosp Med Hum Perform. 2024; 95(6):297-304.


Hemodynamics , Humans , Male , Adult , Hemodynamics/physiology , Young Adult , Heart Rate/physiology , Stroke Volume/physiology , Fluid Shifts/physiology , Weightlessness , Healthy Volunteers , Respiration , Head-Down Tilt/physiology , Inhalation/physiology
...