Results 1 - 20 de 35.682
Filter
1.
Mycopathologia ; 189(4): 68, 2024 Jul 18.
Article in English | MEDLINE | ID: mdl-39023843

ABSTRACT

CONTEXT: Allergic bronchopulmonary mycoses (ABPM) can be due to molds other than Aspergillus fumigatus in patients with cystic fibrosis (pwCF). We aimed to develop immunoassays for the detection of specific IgE (sIgE) directed against five fungal species involved in ABPM: Aspergillus terreus, Scedosporium apiospermum, Lomentospora prolificans, Rasamsonia argillacea, and Exophiala dermatitidis. MATERIALS AND METHODS: Serum samples (n = 356) from 238 pwCF, collected in eight CF care centers in France, Germany, and Italy, were analyzed by dissociated enhanced lanthanide fluorescent immunoassay (DELFIA®) to assess levels of sIgE directed against antigenic extracts of each fungus. Clinical, biological, and radiological data were collected for each episode. One hundred serum samples from healthy blood donors were used as controls. Sera were classified into four groups depending on the level of sIgE according to the quartile repartition calculated for the pwCF population. A score of 4 for values above the 3rd quartile corresponds to an elevated level of sIgE. RESULTS: PwCF showed higher levels of sIgE than controls. Based on criteria from the ABPA-ISHAM working group, with an additional criterion of "a sIgE score of 4 for at least one non-A. fumigatus mold", we were able to diagnose six cases of ABPM. CONCLUSIONS: Using 417 IU/mL as the threshold for total IgE and the same additional criterion, we identified seven additional pwCF with "putative ABPM". Detection of sIgE by DELFIA® showed good analytical performance and supports the role played by non-A. fumigatus molds in ABPM. However, commercially available kits usable in routine practice are needed to improve the diagnosis of ABPM.


Subject(s)
Antibodies, Fungal , Cystic Fibrosis , Fungi , Immunoglobulin E , Humans , Cystic Fibrosis/complications , Immunoglobulin E/blood , Female , Male , Adult , Young Adult , Adolescent , Fungi/immunology , Fungi/classification , Fungi/isolation & purification , Immunoassay/methods , Child , Antibodies, Fungal/blood , Italy , France , Germany , Child, Preschool , Middle Aged , Aspergillosis, Allergic Bronchopulmonary/diagnosis , Aspergillosis, Allergic Bronchopulmonary/immunology , Aspergillosis, Allergic Bronchopulmonary/blood
2.
Methods Mol Biol ; 2829: 277-286, 2024.
Article in English | MEDLINE | ID: mdl-38951344

ABSTRACT

Quantitative immunoassays, such as the traditional enzyme-linked immunosorbent assay (ELISA), are used to determine concentrations of an antigen in a matrix of unknown antigen concentration. Magnetic immunoassays, such as the Luminex xMAP technology, allow for the simultaneous detection of multiple analytes and offer heightened sensitivity, specificity, low sample volume requirements, and high-throughput capabilities. Here, we describe a quantitative immunoassay using the Luminex MAGPIX® System to determine the antigen concentration from liquid samples with unknown concentrations. In detail, we describe a newly developed assay for determining production yields of Drosophila S2-produced Marburg virus (MARV) glycoprotein in insect-cell-culture-derived supernatant. The potential applications of this assay could extend to the quantification of viral antigens in fluids derived from both in vitro and in vivo models infected with live MARV, thereby providing additional applications for virological research.


Subject(s)
Antigens, Viral , Microspheres , Animals , Immunoassay/methods , Antigens, Viral/immunology , Antigens, Viral/analysis , Marburgvirus/immunology , Marburgvirus/isolation & purification , Drosophila , Cell Culture Techniques/methods , Cell Line , Enzyme-Linked Immunosorbent Assay/methods
3.
Vet Med Sci ; 10(4): e1532, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38952277

ABSTRACT

BACKGROUND: Antibodies have been proven effective as diagnostic agents for detecting zoonotic diseases. The variable domain of camel heavy chain antibody (VHH), as an antibody derivative, may be used as an alternative for traditional antibodies in existing immunodiagnostic reagents for detecting rapidly spreading infectious diseases. OBJECTIVES: To expedite the isolation of specific antibodies for diagnostic purposes, we constructed a semi-synthetic camel single domain antibody library based on the phage display technique platform (PDT) and verified the validity of this study. METHODS: The semi-synthetic single domain antibody sequences consist of two parts: one is the FR1-FR3 region amplified by RT-PCR from healthy camel peripheral blood lymphocytes (PBLs), and the other part is the CDR3-FR4 region synthesised as an oligonucleotide containing CDR3 randomised region. The two parts were fused by overlapping PCR, resulting in the rearranged variable domain of heavy-chain antibodies (VHHs). Y. pestis low-calcium response V protein (LcrV) is an optional biomarker to detect the Y. pestis infection. The semi-synthetic library herein was screened using recombinant (LcrV) as a target antigen. RESULTS: After four cycles of panning the library, four VHH binders targeting 1-270 aa residues of LcrV were isolated. The four VHH genes with unique sequences were recloned into an expression vector and expressed as VHH-hFc chimeric antibodies. The purified antibodies were identified and used to develop a lateral flow immunoassay (LFA) test strip using latex microspheres (LM) for the rapid and visual detection of Y. pestis infection. CONCLUSIONS: These data demonstrate the great potential of the semi-synthetic library for use in isolation of antigen-specific nanobodies and the isolated specific VHHs can be used in antigen-capture immunoassays.


Subject(s)
Antigens, Bacterial , Camelus , Single-Domain Antibodies , Yersinia pestis , Animals , Yersinia pestis/immunology , Single-Domain Antibodies/immunology , Antigens, Bacterial/immunology , Plague/diagnosis , Plague/veterinary , Plague/immunology , Immunoassay/methods , Immunoassay/veterinary , Antibodies, Bacterial/immunology
4.
Sex Transm Dis ; 51(8): 545-547, 2024 Aug 01.
Article in English | MEDLINE | ID: mdl-38989902

ABSTRACT

ABSTRACT: At our medical center, HIV nucleic acid tests are recommended when the HIV antigen-antibody screening immunoassay and antibody differentiation tests are discordant, but not done reflexively. A retrospective chart review found that 35% of discordant test results did not have HIV nucleic acid test completed as recommended.


Subject(s)
Algorithms , HIV Infections , Nucleic Acid Amplification Techniques , Humans , HIV Infections/diagnosis , Retrospective Studies , Male , Female , Adult , HIV Testing , RNA, Viral , Mass Screening/methods , Middle Aged , HIV-1/isolation & purification , HIV-1/immunology , HIV Antibodies/blood , Immunoassay/methods
5.
Sci Adv ; 10(28): eadn5698, 2024 Jul 12.
Article in English | MEDLINE | ID: mdl-38985882

ABSTRACT

Gold nanoparticle-based lateral flow immunoassays (AuNP LFIAs) are widely used point-of-care (POC) sensors for in vitro diagnostics. However, the sensitivity limitation of conventional AuNP LFIAs impedes the detection of trace biomarkers. Several studies have explored the size and shape factors of AuNPs and derivative nanohybrids, showing limited improvements or enhanced sensitivity at the cost of convenience and affordability. Here, we investigated surface chemistry on the sensitivity of AuNP LFIAs. By modifying surface ligands, a surface chemistry strategy involving weakly ionized AuNPs enables ultrasensitive naked-eye LFIAs (~100-fold enhanced sensitivity). We demonstrated how this surface chemistry-amplified immunoassay approach modulates nanointerfacial bindings to promote antibody adsorption and higher activity of adsorbed antibodies. This surface chemistry design eliminates complex nanosynthesis, auxiliary devices, or additional reagents while efficiently improving sensitivity with advantages: simplified fabrication process, excellent reproducibility and reliability, and ultrasensitivity toward various biomarkers. The surface chemistry using weakly ionized AuNPs represents a versatile approach for sensitizing POC sensors.


Subject(s)
Gold , Metal Nanoparticles , Point-of-Care Systems , Gold/chemistry , Metal Nanoparticles/chemistry , Immunoassay/methods , Humans , Biosensing Techniques/methods , Reproducibility of Results , Biomarkers/analysis
6.
Sensors (Basel) ; 24(13)2024 Jul 03.
Article in English | MEDLINE | ID: mdl-39001098

ABSTRACT

The quartz tuning fork (QTF) is a promising instrument for biosensor applications due to its advanced properties such as high sensitivity to physical quantities, cost-effectiveness, frequency stability, and high-quality factor. Nevertheless, the fork's small size and difficulty in modifying the prongs' surfaces limit its wide use in experimental research. Our study presents the development of a QTF immunosensor composed of three active layers: biocompatible natural melanin nanoparticles (MNPs), glutaraldehyde (GLU), and anti-IgG layers, for the detection of immunoglobulin G (IgG). Frequency shifts of QTFs after MNP functionalization, GLU activation, and anti-IgG immobilization were measured with an Asensis QTF F-master device. Using QTF immunosensors that had been modified under optimum conditions, the performance of QTF immunosensors for IgG detection was evaluated. Accordingly, a finite element method (FEM)-based model was produced using the COMSOL Multiphysics software program (COMSOL License No. 2102058) to simulate the effect of deposited layers on the QTF resonance frequency. The experimental results, which demonstrated shifts in frequency with each layer during QTF surface functionalization, corroborated the simulation model predictions. A modelling error of 0.05% was observed for the MNP-functionalized QTF biosensor compared to experimental findings. This study validated a simulation model that demonstrates the advantages of a simulation-based approach to optimize QTF biosensors, thereby reducing the need for extensive laboratory work.


Subject(s)
Biosensing Techniques , Immunoglobulin G , Melanins , Nanoparticles , Quartz , Immunoglobulin G/chemistry , Immunoglobulin G/immunology , Biosensing Techniques/methods , Biosensing Techniques/instrumentation , Nanoparticles/chemistry , Melanins/chemistry , Quartz/chemistry , Immunoassay/methods , Immunoassay/instrumentation , Computer Simulation , Antibodies, Anti-Idiotypic/immunology , Antibodies, Anti-Idiotypic/chemistry , Humans
7.
Molecules ; 29(13)2024 Jun 24.
Article in English | MEDLINE | ID: mdl-38998952

ABSTRACT

The sensitivity of immunoassays is generally limited by the low signal reporter/recognition element ratio. Nanomaterials serving as the carriers can enhance the loading number of signal reporters, thus improving the detection sensitivity. However, the general immobilization strategies, including direct physical adsorption and covalent coupling, may cause the random orientation and conformational change in proteins, partially or completely suppressing the enzymatic activity and the molecular recognition ability. In this work, we proposed a strategy to load recognition elements of antibodies and enzyme labels using boronic acid-modified metal-organic frameworks (MOFs) as the nanocarriers for signal amplification. The conjugation strategy was proposed based on the boronate ester interactions between the carbohydrate moieties in antibodies and enzymes and the boronic acid moieties on MOFs. Both enzymes and MOFs could catalyze the oxidation of 3,3',5,5'-tetramethylbenzidine (TMB) by H2O2, therefore achieving dual signal amplification. To indicate the feasibility and sensitivity of the strategy, colorimetric immunoassays of prostate specific antigen (PSA) were performed with boronic acid-modified Cu-MOFs as peroxidase mimics to catalyze TMB oxidation and nanocarriers to load antibody and enzyme (horseradish peroxidase, HRP). According to the change in the absorbance intensity of the oxidized TMB (oxTMB), PSA at the concentration range of 1~250 pg/mL could be readily determined. In addition, this work presented a site-specific and oriented conjugation strategy for the modification of nanolabels with recognition elements and signal reporters, which should be valuable for the design of novel biosensors with high sensitivity and selectivity.


Subject(s)
Boronic Acids , Colorimetry , Metal-Organic Frameworks , Metal-Organic Frameworks/chemistry , Colorimetry/methods , Boronic Acids/chemistry , Immunoassay/methods , Humans , Benzidines/chemistry , Oxidation-Reduction , Prostate-Specific Antigen/analysis , Hydrogen Peroxide/chemistry , Antibodies/chemistry , Biosensing Techniques/methods , Horseradish Peroxidase/chemistry , Horseradish Peroxidase/metabolism
8.
J Vis Exp ; (208)2024 Jun 28.
Article in English | MEDLINE | ID: mdl-39007561

ABSTRACT

Quantum dots, also known as semiconductor nanocrystals, are novel fluorescent labels for biological imaging and sensing. However, quantum dot-antibody conjugates with small dimensions (~10 nm), prepared through laborious purification procedures, exhibit limited sensitivity in detecting certain trace disease markers using lateral flow immunoassay strips. Herein, we present a method for the preparation of quantum dot nanobeads (QDNB) using a one-step emulsion evaporation method. Using the as-prepared QDNB, a fluorescent lateral flow immunoassay was fabricated to detect disease biomarkers using C-reactive protein (CRP) as an example. Unlike single quantum dot nanoparticles, quantum dot nanobead-antibody conjugates are more sensitive as immunoassay labels due to signal amplification by encapsulating hundreds of quantum dots in one polymer composite nanobead. Moreover, the larger size of QDNBs facilitates easier centrifugation separation when conjugating QDNBs with antibodies. The fluorescent lateral flow immunoassay based on QDNBs was fabricated, and the CRP concentration in the sample was measured in 15 min. The test results can be qualitatively assessed under UV light illumination and quantitatively measured using a fluorescent reader within 15 min.


Subject(s)
C-Reactive Protein , Quantum Dots , Quantum Dots/chemistry , Immunoassay/methods , Immunoassay/instrumentation , C-Reactive Protein/analysis , Humans , Fluorescent Dyes/chemistry
9.
World J Microbiol Biotechnol ; 40(9): 269, 2024 Jul 16.
Article in English | MEDLINE | ID: mdl-39009934

ABSTRACT

Gold Nanoparticles (AuNPs) have gained significant attention in biosensor development due to their unique physical, chemical, and optical properties. When incorporated into biosensors, AuNPs offer several advantages, including a high surface area-to-volume ratio, excellent biocompatibility, ease of functionalization, and tunable optical properties. These properties make them ideal for the detection of various biomolecules, including proteins, nucleic acids, and bacterial and viral biomarkers. Traditional methods for detecting bacteria and viruses, such as RT-PCR and ELISA, often suffer from complexities, time consumption, and labor intensiveness. Consequently, researchers are continuously exploring novel devices to address these limitations and effectively detect a diverse array of infectious pathogenic microorganisms. In light of these challenges, nanotechnology has been instrumental in refining the architecture and performance of biosensors. By leveraging advancements in nanomaterials and strategies of biosensor fabrication the sensitivity and specificity of biosensors can be enhanced, enabling more precise detection of pathogenic bacteria and viruses. This review explores the versatility of AuNPs in detecting a variety of biomolecules, including proteins, nucleic acids, and bacterial and viral biomarkers. Furthermore, it evaluates recent advancements in AuNPs-based biosensors for the detection of pathogens, utilizing techniques such as optical biosensors, lateral flow immunoassays, colorimetric immunosensors, electrochemical biosensors, and fluorescence nanobiosensors. Additionally, the study discusses the existing challenges in the field and proposes future directions to improve AuNPs-based biosensors, with a focus on enhancing sensitivity, selectivity, and their utility in clinical and diagnostic applications.


Subject(s)
Bacteria , Biosensing Techniques , Gold , Metal Nanoparticles , Viruses , Biosensing Techniques/methods , Gold/chemistry , Metal Nanoparticles/chemistry , Viruses/isolation & purification , Bacteria/isolation & purification , Nanotechnology/methods , Humans , Biomarkers/analysis , Virus Diseases/diagnosis , Immunoassay/methods
10.
J Med Virol ; 96(7): e29816, 2024 Jul.
Article in English | MEDLINE | ID: mdl-39015036

ABSTRACT

Hepatitis B virus (HBV) RNA and hepatitis B core-related antigen (HBcrAg) have been reported to reflect the transcriptional activity of covalently closed circular HBV DNA. We retrospectively investigated the proportions of quantifiable serum HBV RNA and immunoassay for total antigen including complex via pretreatment-hepatitis B core-related antigen (iTACT-HBcrAg) in chronic hepatitis B patients negative for hepatitis B e antigen (HBeAg) and/or with hepatitis B surface antigen (HBsAg) seroclearance. This study included 246 HBeAg-negative HBV-infected patients, who comprised 13 with liver cirrhosis (LC, the LC group), 118 chronic hepatitis (CH, the CH group), and 115 inactive carriers (IC, the IC group), and 44 patients with HBsAg seroclearance. iTACT-HBcrAg and HBV RNA levels were determined using stored serum samples. Higher proportions of the patients had quantifiable iTACT-HBcrAg than HBV RNA in all groups of HBeAg-negative patients (iTACT-HBcrAg: 84.6%, 90.7%, 35.7%, HBV RNA: 23.1%, 26.3%, 14.8%, for the LC, CH, IC groups). With HBsAg seroclearance (HBsAg <0.05 IU/mL), the proportions of quantifiable samples for HBV RNA were also lower than iTACT-HBcrAg (0% for HBV RNA). Thus, iTACT-HBcrAg was more often detectable than circulating HBV RNA in this study population. Further long-term prospective evaluation of iTACT-HBcrAg is desirable for its utilization in clinical practice.


Subject(s)
Hepatitis B Core Antigens , Hepatitis B Surface Antigens , Hepatitis B e Antigens , Hepatitis B virus , Hepatitis B, Chronic , RNA, Viral , Humans , Hepatitis B, Chronic/virology , Hepatitis B, Chronic/blood , Male , Female , Hepatitis B Surface Antigens/blood , RNA, Viral/blood , Middle Aged , Retrospective Studies , Adult , Hepatitis B virus/genetics , Hepatitis B virus/immunology , Hepatitis B virus/isolation & purification , Hepatitis B Core Antigens/blood , Hepatitis B e Antigens/blood , Aged , Immunoassay/methods
11.
Lab Chip ; 24(14): 3536-3545, 2024 Jul 10.
Article in English | MEDLINE | ID: mdl-38946347

ABSTRACT

Early-stage diagnosis of prostatic carcinoma is essential for successful treatment and, thus, significant prognosis improvement. In laboratory practice, the standard non-invasive diagnostic approach is the immunochemical detection of the associated biomarker, prostate-specific antigen (PSA). Ultrasensitive detection of PSA is essential for both diagnostic and recurrence monitoring purposes. To achieve exceptional sensitivity, we have developed a microfluidic device with a flow-through cell for single-molecule analysis using photon-upconversion nanoparticles (UCNPs) as a detection label. For this purpose, magnetic microparticles (MBs) were first optimized for the capture and preconcentration of PSA and then used to implement a bead-based upconversion-linked immunoassay (ULISA) in the microfluidic device. The digital readout based on counting single nanoparticle-labeled PSA molecules on MBs enabled a detection limit of 1.04 pg mL-1 (36 fM) in 50% fetal bovine serum, which is an 11-fold improvement over the respective analog MB-based ULISA. The microfluidic technique conferred several other advantages, such as easy implementation and the potential for achieving high-throughput analysis. Finally, it was proven that the microfluidic setup is suitable for clinical sample analysis, showing a good correlation with a reference electrochemiluminescence assay (recovery rates between 97% and 105%).


Subject(s)
Prostate-Specific Antigen , Prostate-Specific Antigen/analysis , Prostate-Specific Antigen/blood , Humans , Microfluidic Analytical Techniques/instrumentation , Male , Nanoparticles/chemistry , Immunoassay/instrumentation , Immunoassay/methods , Limit of Detection , Prostatic Neoplasms/diagnosis , Prostatic Neoplasms/blood
12.
Front Endocrinol (Lausanne) ; 15: 1289923, 2024.
Article in English | MEDLINE | ID: mdl-38978630

ABSTRACT

Objective: It is well known that macro-thyroid-stimulating hormone (macro-TSH) could interfere with the detection of TSH. The anti-TSH autoantibody is an essential component of macro-TSH. However, the epidemiological characteristics and the clinical interference of the anti-TSH autoantibody are unclear. Methods: In this study, the radioimmunoprecipitation technique was used to detect the anti-TSH autoantibody. Platforms with different detection mechanisms were applied to measure the TSH in patients with the anti-TSH autoantibody. Polyethylene glycol (PEG) precipitation was used to determine the immunoassay interference. Results: The prevalence of the anti-TSH autoantibody in patients with mild subclinical hypothyroidism (SCH) and autoimmune thyroiditis, but normal thyroid function, was 4.78%. All 10 patients with anti-TSH antibodies had autoimmune diseases, with five of them having significant clinical test interference. Conclusion: The appearance of the anti-TSH antibody is not associated with thyroid autoantibodies. The presence of the anti-TSH autoantibody can interfere with the detection of TSH and can affect clinical diagnosis and treatment.


Subject(s)
Autoantibodies , Hypothyroidism , Thyrotropin , Humans , Autoantibodies/blood , Autoantibodies/immunology , Thyrotropin/blood , Thyrotropin/immunology , Female , Male , Adult , Middle Aged , Hypothyroidism/diagnosis , Hypothyroidism/immunology , Hypothyroidism/blood , Thyroiditis, Autoimmune/immunology , Thyroiditis, Autoimmune/blood , Thyroiditis, Autoimmune/diagnosis , Thyroid Function Tests , Aged , Immunoassay/methods , Radioimmunoprecipitation Assay
13.
Clin Chim Acta ; 561: 119839, 2024 Jul 15.
Article in English | MEDLINE | ID: mdl-38964570

ABSTRACT

Immunoassays are important tools in diagnosing giardiasis, though there are several controversies inherent in the existing methods. We conducted a systematic review and meta-analysis to assess the pooled diagnostic accuracy of immunoassays in detecting the gastrointestinal disease-causing parasite Giardia lamblia. Our comprehensive search, which included PubMed, Scopus, and ScienceDirect from 2000 up until 2023, resulted in 34 studies reporting the performance of 24 different immunoassays. The overall pooled sensitivity and specificity of immunoassays and subgroup analyses were determined. Notably, ImmunoCardSTAT® and RIDASCREEN® Giardia were the most used assays (n = 6 studies each). They exhibited sensitivity and specificity of 84 % and 99 % and 93 % and 99 %, respectively. Sub-group analysis on the type of immunoassays (without the case-control studies) showed that commercial ELISA had higher sensitivity (96 %) compared to a commercial immunochromatographic (88 %), which justifies the difference of sensitivity between ImmunoCardSTAT® and RIDASCREEN® Giardia. However, the applicability between these two in clinical settings, replacing the gold standard, should be considered including the time, equipment requirement, and budget. Samples from symptomatic patients showed higher sensitivity (92 %) compared to asymptomatic patients (79 %). Overall, immunoassays can be a practical replacement for the current gold standard, but more information should be gathered regarding the cost of providing more conclusive suggestions on these findings.


Subject(s)
Giardia lamblia , Giardiasis , Giardia lamblia/immunology , Giardia lamblia/isolation & purification , Immunoassay/methods , Humans , Giardiasis/diagnosis , Giardiasis/immunology
14.
Pan Afr Med J ; 48: 10, 2024.
Article in English | MEDLINE | ID: mdl-38946743

ABSTRACT

Introduction: the utility of glycated haemoglobin (HbA1c) for the diagnosis and monitoring of diabetes in sub-Saharan Africa is uncertain due to limited data on the performance of the available HbA1c assay methods in this population, which has a high prevalence of haemoglobin variants. We aimed to compare the diagnostic accuracy of the major HbA1c methodologies (Boronate Affinity, Capillary Electrophoresis, High Performance Liquid Chromatography, Immunoassay) in an African population, and assess the impact of the common haemoglobin variant HbAS (sickle cell trait). Methods: whole blood samples were obtained from 182 individuals living with type 2 diabetes in Uganda. HbA1c values for each method were compared to average glucose measured over 14 days by continuous glucose monitoring (CGM). To determine concordance, the three HbA1c assay methods were compared to the capillary electrophoresis method. Results: there was a strong correlation between CGM average glucose levels and all four HbA1c methodologies (r=0.81-0.89) which did not differ in those with and without HbAS (present in 37/182 participants). The presence of HbAS did not alter the relationship between HbA1c and CGM glucose for any assay (p for interaction >0.2 for all methods). Diagnostic accuracy for CGM average glucose thresholds of 7 and 10mmol/L was similar across methods (area under the receiver operating characteristic curve 0.80-0.84 and 0.76-0.84 respectively). The maximum bias between the HbA1c assay methodologies was 2 mmol/mol (2.07%). Conclusion: all major HbA1c technologies offer accurate and comparable HbA1c measurement even in this population with high prevalence of haemoglobin variants.


Subject(s)
Blood Glucose , Diabetes Mellitus, Type 2 , Electrophoresis, Capillary , Glycated Hemoglobin , Sensitivity and Specificity , Humans , Glycated Hemoglobin/analysis , Diabetes Mellitus, Type 2/diagnosis , Diabetes Mellitus, Type 2/blood , Electrophoresis, Capillary/methods , Female , Blood Glucose/analysis , Male , Middle Aged , Chromatography, High Pressure Liquid/methods , Uganda , Adult , Immunoassay/methods , Immunoassay/standards , Blood Glucose Self-Monitoring/methods , Aged , Hemoglobins, Abnormal/analysis
15.
Anal Chim Acta ; 1316: 342813, 2024 Aug 08.
Article in English | MEDLINE | ID: mdl-38969419

ABSTRACT

In the immunoassay process, for fulfilling the need to identify multiple analytes in a small amount of complex sample matrix, it is desirable to develop highly efficient and specific multiplex suspension array technology. Raman coding strategy offers an attractive solution to code the suspension arrays by simply combing narrow spectral bands with stable signal intensities through solid-phase synthesis on the resin beads. Based on this strategy, we report the bead-based spontaneous Raman codes for multiplex immunoassay. The study resulted in superior selectivity of the Raman-encoded beads for binding with single and multiple analytes, respectively. With the use of mixed types of Raman-encoded immunoassay beads, multiple targets in small amounts of samples were identified rapidly and accurately. By confirming the feasibility of bead-based spontaneous Raman codes for multiplex immunoassay, we anticipate this novel technology to be widely applied in the near future.


Subject(s)
Spectrum Analysis, Raman , Spectrum Analysis, Raman/methods , Immunoassay/methods , Humans
16.
J Agric Food Chem ; 72(26): 14967-14974, 2024 Jul 03.
Article in English | MEDLINE | ID: mdl-38957086

ABSTRACT

Nanobodies (Nbs) serve as powerful tools in immunoassays. However, their small size and monovalent properties pose challenges for practical application. Multimerization emerges as a significant strategy to address these limitations, enhancing the utilization of nanobodies in immunoassays. Herein, we report the construction of a Salmonella-specific fenobody (Fb) through the fusion of a nanobody to ferritin, resulting in a self-assembled 24-valent nanocage-like structure. The fenobody exhibits a 35-fold increase in avidity compared to the conventional nanobody while retaining good thermostability and specificity. Leveraging this advancement, three ELISA modes were designed using Fb as the capture antibody, along with unmodified Nb422 (FbNb-ELISA), biotinylated Nb422 (FbBio-ELISA), and phage-displayed Nb422 (FbP-ELISA) as the detection antibody, respectively. Notably, the FbNb-ELISA demonstrates a detection limit (LOD) of 3.56 × 104 CFU/mL, which is 16-fold lower than that of FbBio-ELISA and similar to FbP-ELISA. Moreover, a fenobody and nanobody sandwich chemiluminescent enzyme immunoassay (FbNb-CLISA) was developed by replacing the TMB chromogenic substrate with luminal, resulting in a 12-fold reduction in the LOD. Overall, the ferritin-displayed technology represents a promising methodology for enhancing the detection performance of nanobody-based sandwich ELISAs, thereby expanding the applicability of Nbs in food detection and other fields requiring multivalent modification.


Subject(s)
Enzyme-Linked Immunosorbent Assay , Ferritins , Salmonella , Single-Domain Antibodies , Ferritins/immunology , Ferritins/chemistry , Ferritins/genetics , Single-Domain Antibodies/chemistry , Single-Domain Antibodies/genetics , Single-Domain Antibodies/immunology , Salmonella/immunology , Salmonella/genetics , Enzyme-Linked Immunosorbent Assay/methods , Limit of Detection , Antibody Affinity , Antibodies, Bacterial/immunology , Immunoassay/methods
17.
Mikrochim Acta ; 191(8): 453, 2024 07 06.
Article in English | MEDLINE | ID: mdl-38970675

ABSTRACT

An electrochemical biosensor has been developed for detection of Escherichia coli O157 by integrating lateral flow with screen-printed electrodes. The screen-printed electrodes were attached under the lateral flow detection line, and organic-inorganic nanoflowers prepared from E. coli O157-specific antibodies as an organic component were attached to the lateral flow detection line. In the presence of E. coli O157, an organic-inorganic nanoflower-E. coli O157-antimicrobial peptide-labelled ferrocene sandwich structure is formed on the lateral flow detection line. Differential pulse voltammetry is applied using a smartphone-based device to monitor ferrocene on the detection line. The resulting electrochemical biosensor could specifically detect E. coli O157 with a limit of detection of 25 colony-forming units mL-1. Through substitution of antibodies of organic components in organic-inorganic nanoflowers, biosensors have great potential for the detection of other pathogens in biomedical research and clinical diagnosis.


Subject(s)
Biosensing Techniques , Electrochemical Techniques , Escherichia coli O157 , Escherichia coli O157/isolation & purification , Escherichia coli O157/immunology , Biosensing Techniques/methods , Immunoassay/methods , Immunoassay/instrumentation , Electrochemical Techniques/methods , Electrochemical Techniques/instrumentation , Limit of Detection , Nanostructures/chemistry , Electrodes , Ferrous Compounds/chemistry , Antibodies, Immobilized/immunology , Metallocenes/chemistry , Antibodies, Bacterial/chemistry , Antibodies, Bacterial/immunology , Antimicrobial Peptides/chemistry
18.
Mikrochim Acta ; 191(7): 434, 2024 06 29.
Article in English | MEDLINE | ID: mdl-38951317

ABSTRACT

An enhanced lateral flow assay (LFA) is presented for rapid and highly sensitive detection of acute respiratory syndrome coronavirus-2 (SARS-CoV-2) antigens with gold nanoflowers (Au NFs) as signaling markers and gold enhancement to amplify the signal intensities. First, the effect of the morphology of gold nanomaterials on the sensitivity of LFA detection was investigated. The results showed that Au NFs prepared by the seed growth method showed a 5-fold higher detection sensitivity than gold nanoparticles (Au NPs) of the same particle size, which may benefit from the higher extinction coefficient and larger specific surface area of Au NFs. Under the optimized experimental conditions, the Au NFs-based LFA exhibited a detection limit (LOD) of 25 pg mL-1 for N protein using 135 nm Au NFs as the signaling probes. The signal was further amplified by using a gold enhancement strategy, and the LOD for the detection of N protein achieved was 5 pg mL-1. The established LFA also exhibited good repeatability and stability and showed applicability in the diagnosis of SARS-CoV-2 infection.


Subject(s)
Antigens, Viral , Coronavirus Nucleocapsid Proteins , Gold , Limit of Detection , Metal Nanoparticles , SARS-CoV-2 , Gold/chemistry , SARS-CoV-2/immunology , Metal Nanoparticles/chemistry , Humans , Antigens, Viral/analysis , Antigens, Viral/immunology , Coronavirus Nucleocapsid Proteins/immunology , Coronavirus Nucleocapsid Proteins/analysis , Phosphoproteins/immunology , Phosphoproteins/analysis , Phosphoproteins/chemistry , COVID-19/diagnosis , COVID-19/virology , Immunoassay/methods , COVID-19 Serological Testing/methods
19.
Anal Chim Acta ; 1317: 342866, 2024 Aug 15.
Article in English | MEDLINE | ID: mdl-39030026

ABSTRACT

BACKGROUND: Cardiac troponin I (CTnI) is demonstrated as one of the most promising disease biomarkers for early diagnosing acute myocardial infarction (AMI). To date, electrochemical immunosensors have been extensively studied in the field of cTnI determination. But highly accurate and sensitive cTnI detection by this method is still a challenge due to non-specific adsorption on electrode interfaces in complex human serum. As a result, it is necessary to develop an antifouling electrochemical immunosensor with high sensitivity for the detection of cTnI. RESULTS: In this work, an antifouling electrochemical immunosensor was constructed based on vertically-aligned peptide layer consisting of Au nanoparticles (AuNPs) and amphiphilic CEAK16 peptide (CEAK16@AuNPs) for sensitive and accurate detection of cTnI in human serum. The vertically-aligned CEAK16@AuNPs interface provided a stable hydration layer originated from attraction of water molecules by amino acids on the hydrophilic side of the CEAK16, which effectively reduced non-specific adsorption and enhanced electron transfer rate. The cTnI immunosensor possessed great analytical performance with a wide range from 1 fg mL-1 to 1 µg mL-1 and a low detection limit of 0.28 fg mL-1 (S/N = 3). Additionally, the proposed CEAK16@AuNPs sensing interface showed excellent long-term antifouling performance and electrochemical activity that preserved 80 % of the initial signal after 20-days exposure in human serum samples. Consequently, the cTnI immunosensor displayed excellent detection accuracy compared to clinical methods and owned good selectivity, stability and reproducibility. SIGNIFICANCE: The development of this strategy provides a versatile tool for accurate quantitative cTnI analysis in real human serum, thus helping to achieve early AMI diagnosis effectively and holding the promising potentials for other immunosensor in disease diagnosis.


Subject(s)
Electrochemical Techniques , Gold , Metal Nanoparticles , Troponin I , Humans , Troponin I/blood , Gold/chemistry , Metal Nanoparticles/chemistry , Limit of Detection , Biosensing Techniques , Peptides/chemistry , Immunoassay/methods , Antibodies, Immobilized/immunology , Antibodies, Immobilized/chemistry , Electrodes
20.
Anal Chim Acta ; 1317: 342887, 2024 Aug 15.
Article in English | MEDLINE | ID: mdl-39030019

ABSTRACT

BACKGROUND: Procollagen type III N-terminal peptide (P-III-NP) is a fibrosis biomarker associated with liver and cardiac fibrosis. Despite the value of P-III-NP as a biomarker, its analysis currently relies on enzyme-linked immunosorbent assays (ELISA) and radioimmunoassays (RIA), which require more than 3 h. To facilitate early diagnosis and treatment through rapid biomarker testing, we developed a one-step immunoassay for P-III-NP using a quenchbody, which is a fluorescence-labeled immunosensor for immediate signal generation. RESULTS: To create quenchbodies, the total mRNA of P-III-NP antibodies was extracted from early-developed hybridoma cells, and genes of variable regions were obtained through cDNA synthesis, inverse PCR, and sequencing. A single-chain variable fragment (scFv) with an N-terminal Cys-tag was expressed in E. coli Shuffle T7, resulting in a final yield of 9.8 mg L-1. The fluorescent dye was labeled on the Cys-tag of the anti-P-III-NP scFv using maleimide-thiol click chemistry, and the spacer arm lengths between the maleimide-fluorescent dyes were compared. Consequently, a TAMRA-C6-labeled quenchbody exhibited antigen-dependent fluorescence signals and demonstrated its ability to detect P-III-NP at concentrations as low as 0.46 ng mL-1 for buffer samples, 1.0 ng mL-1 for 2 % human serum samples. SIGNIFICANCE: This one-step P-III-NP detection method provides both qualitative and quantitative outcomes within a concise 5-min timeframe. Furthermore, its application can be expanded using a 96-well platform and human serum, making it a high-throughput and sensitive method for testing fibrotic biomarkers.


Subject(s)
Biomarkers , Fibrosis , Fluorescent Dyes , Peptide Fragments , Procollagen , Biomarkers/blood , Biomarkers/analysis , Humans , Fluorescent Dyes/chemistry , Procollagen/blood , Procollagen/chemistry , Peptide Fragments/chemistry , Peptide Fragments/immunology , Single-Chain Antibodies/chemistry , Single-Chain Antibodies/immunology , Biosensing Techniques , Immunoassay/methods
SELECTION OF CITATIONS