Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 5.920
Filter
2.
Zhongguo Yi Liao Qi Xie Za Zhi ; 48(4): 430-433, 2024 Jul 30.
Article in Chinese | MEDLINE | ID: mdl-39155258

ABSTRACT

Objective: To investigate the impact of different infusion media on the flow rate of infusion pumps. Methods: Ten infusion pumps were randomly selected and tested for infusion rates using deionized water, saline solution, glucose solution, and parenteral nutrition solution. The infusion flow rate was set at 30 mL/h, and the testing methodology conformed to the standards for the calibration and quality control of syringe pumps and infusion pumps. Results: For infusion set A, the infusion rate was unaffected by the infusion media, remaining within the acceptable quality control standards. For infusion set B, when infused with deionized water, saline solution, and glucose solution, the infusion errors were within the quality control standards. However, when using parenteral nutrition solution as the infusion medium, the infusion error exceeded the acceptable quality control standards. Conclusion: Both the infusion set and the infusion medium can affect the flow rate of infusion pumps. It is crucial to calibrate the flow rate according to the specific infusion medium to reduce medical risks associated with infusion pumps during clinical use.


Subject(s)
Infusion Pumps , Glucose/administration & dosage , Saline Solution/administration & dosage , Quality Control , Calibration , Parenteral Nutrition Solutions , Water
3.
Eur Radiol Exp ; 8(1): 90, 2024 Aug 01.
Article in English | MEDLINE | ID: mdl-39090480

ABSTRACT

Prostate-specific membrane antigen (PSMA) targeted tracers show increased uptake in several malignancies, indicating a potential for peptide radioligand therapy. Intra-arterial injection of radiotracers can increase the therapeutic window. This study aimed to evaluate the feasibility of intra-arterial injection of [68Ga]Ga-PSMA-11 for intrahepatic cholangiocarcinoma and compare tracer uptake after intrahepatic arterial injection and intravenous injection. Three patients with intrahepatic cholangiocarcinoma received [68Ga]Ga-PSMA-11 through a hepatic arterial infusion pump, followed by positron emission tomography/computed tomography (PET/CT). Two-three days later, patients underwent PET/CT after intravenous [68Ga]Ga-PSMA-11 injection. All tumours showed higher uptake on the intra-arterial scan compared with the intravenous scan: the intra-arterial / intravenous standardised uptake value normalised by lean body mass ratios were 1.40, 1.46, and 1.54. Local intra-arterial PSMA injection is possible in patients with intrahepatic cholangiocarcinoma. Local injection increases tumour-to-normal tissue ratios, increasing the therapeutic window for theranostic applications. RELEVANCE STATEMENT: Intra-arterial Prostate specific membrane antigen (PSMA) injection increases the therapeutic window for potential theranostic application in intrahepatic cholangiocarcinoma. KEY POINTS: Three patients with intrahepatic cholangiocarcinoma underwent PET/CT after intra-arterial and intravenous injection of [68Ga]Ga-PSMA-11. Intra-arterial injection showed higher uptake than intravenous injection. PSMA-targeted imaging could be valuable for a subset of intrahepatic cholangiocarcinoma patients.


Subject(s)
Bile Duct Neoplasms , Cholangiocarcinoma , Gallium Radioisotopes , Positron Emission Tomography Computed Tomography , Humans , Cholangiocarcinoma/diagnostic imaging , Positron Emission Tomography Computed Tomography/methods , Bile Duct Neoplasms/diagnostic imaging , Bile Duct Neoplasms/drug therapy , Male , Middle Aged , Aged , Gallium Radioisotopes/administration & dosage , Hepatic Artery/diagnostic imaging , Proof of Concept Study , Gallium Isotopes , Injections, Intra-Arterial , Female , Infusions, Intra-Arterial , Oligopeptides/administration & dosage , Feasibility Studies , Infusion Pumps , Radiopharmaceuticals/administration & dosage
5.
Int J Pharm ; 663: 124577, 2024 Sep 30.
Article in English | MEDLINE | ID: mdl-39137820

ABSTRACT

This study investigates the impact of intravenous (IV) infusion protocols on the stability of Intravenous Immunoglobulin G (IVIG) and Rituximab, with a particular focus on subvisible particle generation. Infusion set based on peristaltic movement (Medifusion DI-2000 pump) was compared to a gravity-based infusion system (Accu-Drip) at different flow rates. The impacts of different diluents (0.9 % saline and 5.0 % dextrose) and plastic syringes with or without silicone oil (SO) were also investigated. The results from the aforementioned particular case demonstrated that peristaltic pumps generated high levels of subvisible particles (prominently < 25 µm), exacerbated by increasing flow rates, specifically in formulations lacking surfactants. Other factors, such as diluent type and syringe composition, also increased the number of subvisible particles. Strategies that can help overcome these complications include surfactant addition as well as the use of SO-free syringes and a gravity infusion system, which aid in reducing particle formation and preserving antibody monomer during administration. Altogether, these findings highlight the importance of the careful selection of formulations and infusion protocols to minimize particle generation during IV infusion both for patients' safety and treatment efficacy.


Subject(s)
Drug Stability , Immunoglobulins, Intravenous , Rituximab , Syringes , Rituximab/administration & dosage , Rituximab/chemistry , Infusions, Intravenous , Immunoglobulins, Intravenous/administration & dosage , Immunoglobulins, Intravenous/chemistry , Infusion Pumps , Surface-Active Agents/chemistry , Silicone Oils/chemistry , Drug Packaging , Plastics/chemistry , Glucose/chemistry , Humans
6.
Surg Endosc ; 38(9): 5108-5113, 2024 Sep.
Article in English | MEDLINE | ID: mdl-39017958

ABSTRACT

BACKGROUND: Hepatic arterial infusion pump (HAIP) treatment is a technique used to treat liver localized malignancy with intra-arterial chemotherapy. Methylene blue is generally administered to verify hepatic perfusion and exclude inadvertent extrahepatic perfusion. The use of indocyanine green dye (ICG) combined with near-infrared (NIR) fluorescence imaging during robot-assisted HAIP placement may be an attractive alternative by providing high contrast without blue discoloration of the operative field. METHODS: Data was collected retrospectively from 2 centers in the Netherlands. Intraoperative perfusion of the liver segments and extrahepatic perfusion were assessed using ICG/NIR as well as methylene blue on video imaging and correlated to postoperative 99 m-Tc perfusion scintigraphy. RESULTS: 13 patients underwent robot-assisted surgery for HAIP placement; median length of stay was 4 days, complications occurred in 4 patients. Hepatic perfusion showed identical patterns when ICG was compared with methylene blue. In 1 patient, additional extrahepatic perfusion was found using ICG, leading to further vessel ligation. Intraoperative ICG perfusion was concordant with 99 m-Tc perfusion scintigraphy. DISCUSSION: Liver and extrahepatic perfusion determined by ICG fluorescence imaging is concordant with blue dye perfusion and 99 m-Tc perfusion scintigraphy. Therefore, ICG fluorescence imaging is deemed a safe and reliable technique for perfusion testing during robot-assisted HAIP placement.


Subject(s)
Coloring Agents , Hepatic Artery , Indocyanine Green , Liver Neoplasms , Robotic Surgical Procedures , Humans , Indocyanine Green/administration & dosage , Male , Female , Retrospective Studies , Middle Aged , Robotic Surgical Procedures/methods , Aged , Liver Neoplasms/surgery , Liver Neoplasms/diagnostic imaging , Hepatic Artery/diagnostic imaging , Coloring Agents/administration & dosage , Infusions, Intra-Arterial , Optical Imaging/methods , Infusion Pumps , Perfusion Imaging/methods , Methylene Blue/administration & dosage , Adult
7.
Anesth Analg ; 139(3): 545-554, 2024 Sep 01.
Article in English | MEDLINE | ID: mdl-38905148

ABSTRACT

BACKGROUND: Three settings are required on a programmed intermittent epidural bolus (PIEB) pump for labor analgesia: the PIEB next bolus (PIEBnb), PIEB interval (PIEBi), and PIEB volume (PIEBv). The ideal settings for these parameters are still unknown. We hypothesized a mathematical modeling tool, response surface methodology (RSM), could estimate 3 PIEB pump parameters while balancing 3 clinically important patient outcomes simultaneously. The study objective was to use RSM to estimate PIEB settings (PIEBnb, PIEBi, and PIEBv) while maximizing maternal satisfaction, minimizing the need for clinician-administered boluses, and optimizing the ratio of delivered/requested patient-controlled epidural analgesia (PCEA) boluses simultaneously. METHODS: With institutional ethics approval, a double-blind randomized trial was completed in a tertiary care labor and delivery center. Nulliparous, English-speaking American Society of Anesthesiologists (ASA) physical status II patients aged 18 to 45 years at full term, single gestation in vertex presentation, in spontaneous labor and ≤7 cm cervical dilation were included. Patients with comorbidities, contraindications to neuraxial analgesia, using chronic analgesics, <152 cm, or body mass index (BMI) >45 kg/m 2 were excluded. After informed consent, labor analgesia was initiated using 10 mL ropivacaine 0.2% with 10 µg/mL fentanyl solution and PCEA (volume 6 mL every 10 minutes). Patients were randomized to predetermined PIEB settings. RSM identified 3 pump settings that represented a stationary point that best maximized or minimized 3 outcomes simultaneously: PCEA ratio (a ratio closest to 1), clinician bolus (optimal is 0), and maternal satisfaction (visual analog scale, 0-100, ideal response is ≥90). RESULTS: Of 287 potential participants, 192 did not meet inclusion criteria or declined to participate, and 26 were withdrawn, leaving 69 patients for study inclusion. Using RSM, the suggested PIEB settings for all the primary study outcomes were as follows: PIEBnb = 29.4 minutes, PIEBi = 59.8 minutes, and PIEBv = 6.2 mL. These PIEB settings corresponded to the following clinical outcomes: maternal satisfaction at 93.9%, PCEA ratio at 0.77, and need for clinician bolus at 0.29. The dermatome sensory score was between T10 and T5 in 89% of the patients. The median lowest Bromage score was 4. CONCLUSIONS: This novel study used a mathematical model to estimate PIEB pump settings while simultaneously maximizing 3 clinical outcomes. Equally weighted clinical outcomes prevent maximal outcome optimization and may not reflect patient priorities. Future studies or quality improvement endeavors could use RSM methodology to estimate PIEB pump settings targeting optimal values for a single clinical outcome of determined importance to parturients.


Subject(s)
Analgesia, Epidural , Analgesia, Obstetrical , Analgesia, Patient-Controlled , Humans , Female , Pregnancy , Adult , Double-Blind Method , Analgesia, Epidural/methods , Analgesia, Obstetrical/methods , Analgesia, Patient-Controlled/methods , Young Adult , Anesthetics, Local/administration & dosage , Labor Pain/drug therapy , Labor Pain/diagnosis , Treatment Outcome , Patient Satisfaction , Adolescent , Analgesics, Opioid/administration & dosage , Infusion Pumps , Pain Measurement , Drug Administration Schedule
8.
Nurs Stand ; 39(8): 39-44, 2024 07 31.
Article in English | MEDLINE | ID: mdl-38898723

ABSTRACT

RATIONALE AND KEY POINTS: This article explains how to prepare and administer an intravenous (IV) infusion using a gravity administration (giving) set or a volumetric pump in a safe, effective manner. Nurses undertaking this procedure must ensure they have the knowledge and skills to do so and work within the limits of their competence. This article serves as a revision of best practice in administering IV infusions of fluids and medicines. • IV infusions are delivered directly into the bloodstream, so care must be taken to protect the patient from harm by following the appropriate policies and protocols and monitoring the patient carefully for adverse reactions. • There is a risk of administering large volumes of IV fluid to the patient when using a gravity administration set, so a burette or volumetric pump should be used in patients who may not tolerate this. • Volumetric pumps vary, so it is essential that the nurse is familiar with the device, uses the specific administration set required and follows the manufacturer's instructions. REFLECTIVE ACTIVITY: 'How to' articles can help to update your practice and ensure it remains evidence-based. Apply this article to your practice. Reflect on and write a short account of: • How this article might improve your practice when preparing and administering an IV infusion. • How you could use this information to educate nursing students or your colleagues on the appropriate methods for preparing and administering an IV infusion.


Subject(s)
Infusion Pumps , Infusions, Intravenous/methods , Infusions, Intravenous/instrumentation , Humans , United Kingdom , Gravitation , Clinical Competence
9.
J Control Release ; 372: 674-681, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38909700

ABSTRACT

One of the primary obstacles in treating central nervous system (CNS) disorders lies in the limited ability of disease-modifying drugs to cross the blood-brain barrier (BBB). Our previously described Minimally Invasive Nasal Depot (MIND) technique has proven successful in delivering various drugs to the brain in rat models via a trans-olfactory mucosal approach. In this study, we introduce a novel Minimally Invasive Nasal Infusion (MINI) delivery approach for administering ovalbumin, a model protein, utilizing a programmable infusion pump (iPRECIO SMP-310R) in a mouse model. This research highlights the significant role of olfactory mucosa in nose-to-brain delivery, with an efficacy of nearly 45% compared to intracerebroventricular (ICV) administration. This demonstrates its potential as an alternative procedure for treating CNS diseases, offering a greater safety profile relative to the highly invasive clinical routes traditionally adopted for CNS drug delivery.


Subject(s)
Administration, Intranasal , Ovalbumin , Animals , Ovalbumin/administration & dosage , Drug Delivery Systems , Male , Mice , Brain/metabolism , Infusion Pumps , Blood-Brain Barrier/metabolism , Mice, Inbred C57BL
10.
Zhonghua Wei Zhong Bing Ji Jiu Yi Xue ; 36(5): 543-545, 2024 May.
Article in Chinese | MEDLINE | ID: mdl-38845504

ABSTRACT

Intravenous infusion is an important route of drug therapy, and infusion safety is an important issue for medical staff. Long-term and multiple infusion routes at the same time bring inconvenience to patients. Multiple three-way switches in parallel infusion may lead to interruption of the liquid route, which can seriously endanger the life of patients. To address these clinical issues, medical staff from the School of Basic Medical Sciences of Hebei Medical University and the Emergency Department of the Second Hospital of Hebei Medical University designed a multiple combination portable infusion assistance device and obtained the National Utility Model Patent of China (ZL 2022 2 0226073.2). The device is mainly composed of adhesive tape sticker, fixed slots and pipelines, and also includes a three-way valve and a mixing chamber, and different modes of infusion assist devices can be selected according to clinical needs. The device is simple and convenient to operate, solves the problem of multiple liquid infusion blockages, improves the safety and comfort of infusion, and can meet the needs of liquid infusion in various clinical situations.


Subject(s)
Equipment Design , Humans , Infusions, Intravenous/instrumentation , Infusions, Intravenous/methods , Infusion Pumps
11.
Curr Opin Anaesthesiol ; 37(4): 362-370, 2024 Aug 01.
Article in English | MEDLINE | ID: mdl-38841991

ABSTRACT

PURPOSE OF REVIEW: The drug titration paradox describes that, from a population standpoint, drug doses appear to have a negative correlation with its clinical effect. This paradox is a relatively modern discovery in anesthetic pharmacology derived from large clinical data sets. This review will interpret the paradox using a control engineering perspective. RECENT FINDINGS: Drug titration is a challenging endeavor, and the medication delivery systems used in everyday clinical practice, including infusion pumps and vaporizers, typically do not allow for rapid or robust titration of medication being delivered. In addition, clinicians may be reluctant to deviate from a predetermined plan or may be content to manage patients within fixed goal boundaries. SUMMARY: This drug titration paradox describes the constraints of how the average clinician will dose a patient with an unknown clinical response. While our understanding of the paradox is still in its infancy, it remains unclear how alternative dosing schemes, such as through automation, may exceed the boundaries of the paradox and potentially affect its conclusions.


Subject(s)
Anesthetics , Humans , Anesthetics/administration & dosage , Drug Delivery Systems/methods , Dose-Response Relationship, Drug , Infusion Pumps/standards
12.
Hosp Pediatr ; 14(6): 448-454, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38716570

ABSTRACT

BACKGROUND AND OBJECTIVES: Intravenous infusions have the potential to cause significant harm in patients and are associated with a high rate of adverse drug events and medication errors. Infusion pumps with dose error reduction software (DERS) can be used to reduce errors by establishing safe infusion parameters. In 2019, a quality improvement project was initiated with the aim to increase DERS compliance from 46% to 75% at our specialty institution by October 1, 2022. METHODS: An interdisciplinary group was tasked with improving compliance with DERS by identifying key drivers, including informed staff, engaged staff, and an accurate smart pump library. We used the Model for Improvement framework to guide this improvement project, and Plan-Do-Study-Act (PDSA) cycles were used to plan for interventions. PDSA cycles included drug library updates, education, and unit-level compliance reporting. Weekly average DERS compliance was monitored as the outcome measure, and weekly pump alerts per 100 infusions were monitored as a balancing measure; statistical process control charts were used to monitor measures from 2018 to 2022. RESULTS: Over the course of 25 months, 8 PDSA cycles resulted in 5 centerline improvements from a baseline mean of 46% to a final mean of 78%. Pump alerts per 100 infusions decreased from 15.9 to 6.4 with the first PDSA cycle and then continued to decrease to 3.9 with subsequent interventions. CONCLUSIONS: Although features like DERS can help ensure safe medication administration, continuous improvement efforts to increase DERS compliance without increasing alert burden are needed to ensure that benefits of this technology are optimized.


Subject(s)
Infusion Pumps , Medication Errors , Quality Improvement , Software , Humans , Infusion Pumps/standards , Medication Errors/prevention & control , Medication Errors/statistics & numerical data , Infusions, Intravenous
13.
Adv Healthc Mater ; 13(19): e2304573, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38558375

ABSTRACT

In clinical treatments, reliable flow rate measurements ensure accurate drug delivery during infusions, precise gas delivery during artificial ventilations, etc., thereby reducing patient morbidity and mortality. However, precise flow rate sensors are costly, so medical devices with limited budgets choose cheaper but unsatisfactory flow rate measurement approaches, leading to increased medical risks. Here, a photoelectric flow rate sensor based on a flexible planar curved beam structure (FPCBS) is proposed. The FPCBS ensures low out-of-plane stiffness of the sensitive sheet and allows large deformation in the elastic range, enabling the flow rate sensor to measure the flow rate with high sensitivity over a wide range. Meanwhile, the flow rate sensor can be mass-produced using mature materials and manufacturing technology at less than $5 each. The flow rate sensors are integrated into a commercial infusion pump to measure drug infusion and a home ventilator to monitor respiration. The results are comparable to those measured by a commercial flow rate sensor, demonstrating the applicability of the sensor. Considering its proven outstanding performance at low cost, the flow rate sensor shows great potential in clinical treatment, medical diagnosis, and other medical fields.


Subject(s)
Equipment Design , Humans , Infusion Pumps , Drug Delivery Systems/instrumentation , Drug Delivery Systems/methods
14.
Farm Hosp ; 48(4): T153-T158, 2024.
Article in English, Spanish | MEDLINE | ID: mdl-38679534

ABSTRACT

OBJECTIVES: To describe the experience of home antibiotic infusion therapy using elastomeric infusion pumps, administered to patients admitted to the Home Hospitalisation Unit of a tertiary hospital for 3 years and to analyse clinical evolution and mortality. METHOD: Retrospective observational study. The medical history of the patients included in the study was reviewed. Information was obtained on personal history, antimicrobial therapy received, and clinical evolution. Statistical analysis was performed using SPSS® 19 software. RESULTS: 81 patients were included, 61.7% men, with a mean age of 73.5±17.5 years. The most frequent comorbidities were diabetes mellitus (30.9%) and chronic kidney disease (28.4%). Patients received a mean of 11.9±8.5 days of antibiotic treatment in an elastomeric infusion pump. The main focus of infection was respiratory (27.2%), followed by bacteremia (16%) and skin and soft tissue infections (12.3%). Of the infections, 65.4% were monomicrobial, with Pseudomonas aeruginosa being the main microorganism involved (39.6%). The most commonly used antimicrobial was piperacillin/tazobactam (33.3%). The clinical course was good in 85.2% of the patients, but the mortality rate in the 30 days following the end of treatment was 24.7%. In the univariate analysis, a history of neoplasia in the last 5 years (p=.01) and having received fewer days of antibiotic therapy prior to the start of outpatient antimicrobial therapy in infusion pump (p=.04) were associated with worse clinical outcome. Age over 80 years was associated with better outcome (p=.03). The diagnosis of heart failure was associated with higher mortality (p=.026) and patients from surgical services, with lower mortality (p=.047). In the multivariate analysis, the presence of neoplasia was associated with unfavourable evolution (p=.012) and heart failure with higher mortality (p=.027). CONCLUSIONS: Outpatient antimicrobial therapy in elastomeric infusion pumps is an alternative in patients requiring prolonged intravenous treatment, and age is not a conditioning factor for inclusion in these programs. However, the presence of certain comorbidities can negatively affect the clinical course and mortality of patients.


Subject(s)
Anti-Bacterial Agents , Home Infusion Therapy , Infusion Pumps , Humans , Retrospective Studies , Male , Female , Aged , Anti-Bacterial Agents/administration & dosage , Anti-Bacterial Agents/therapeutic use , Aged, 80 and over , Middle Aged , Elastomers
16.
Ann Surg Oncol ; 31(7): 4449-4451, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38632219

ABSTRACT

BACKGROUND: Hepatic artery infusion pump (HAIP) with floxuridine/dexamethasone and systemic chemotherapy is an established treatment regimen, which had been reported about converting 47% of patients with stage 4 colorectal liver metastasis from unresectable to resectable.1,2 To this effect, HAIP chemotherapy contributes to prolonged survival of many patients, which otherwise may not have other treatment options. Biliary sclerosis, however, is a known complication of the HAIP treatment, which occurs in approximately 5.5% of patients receiving this modality as an adjuvant therapy after hepatectomy and in 2% of patients receiving HAIP treatment for unresectable disease.3 While biliary sclerosis diffusely affects the perihilar and intrahepatic biliary tree, a dominant stricture maybe found in select cases, which gives an opportunity for a local surgical treatment after failure of endoscopic stenting/dilations. While the use of minimally invasive approach to biliary surgery is gradually increasing,4 there have been no descriptions of its application in this scenario. In this video, we demonstrate the use of minimally invasive robotic technique for biliary stricturoplasty and Roux-en-Y (RY) hepaticojejunostomy to treat persistent right hepatic duct stricture after HAIP chemotherapy. PATIENT: A 68-year-old woman with history of multifocal bilobar stage 4 colorectal liver metastasis presented to our office with obstructive jaundice and recurrent cholangitis that required nine endoscopic retrograde cholangiopancreatographies (ERCPs) and a placement of internal-external percutaneous transhepatic biliary drain (PTBD) by interventional radiology within the past 2 years. Her past surgical history was consistent with laparoscopic right hemicolectomy 3 years prior, followed by a left lateral sectorectomy with placement of an HAIP for adjuvant treatment. The patient had more than ten metastatic liver lesions within the right and left lobe, ranging from 2 to 3 cm in size at the time of HAIP placement. The patient had a histologically normal background liver parenchyma before the HAIP chemotherapy treatment. The patient did not have any history of alcohol use, diabetes mellitus, metabolic syndrome, nonalcoholic steatohepatitis, or other underlying intrinsic liver disorders, which are known to contribute to the development of hepatic fibrosis. Despite a radiologically disease-free status, the patient started to have episodes of acute cholangitis 1 year after the placement of HAIP that required multiple admissions to a local hospital. The HAIP was subsequently removed once the diagnosis of biliary sclerosis was made despite dose reductions and treatment with intrahepatic dexamethasone for almost 1 year. In addition to this finding, the known liver metastases have shown complete radiological resolution. Therefore further treatment with HAIP was deemed unnecessary, and pump removal was undertaken. Magnetic resonance imaging showed a dominant stricture at the junction of the right anterior and right posterior sectoral hepatic duct. The location of the dominant stricture was confirmed by an ERCP and cholangioscopy. Absence of neoplasia was confirmed with multiple cholangioscopic biopsies. Multiple endoscopic and percutaneous attempts with stent placement failed to dilate the area of stricture. Postprocedural cholangiographies showed a persistent significant narrowing, which led to multiple recurrent obstructive jaundice and severe cholangitis. While the use of surgical approach is rarely needed in the treatment of biliary sclerosis, a decision was made after extensive multidisciplinary discussions to perform a robotic stricturoplasty and RY hepaticojejunostomy with preservation of the native common bile duct. TECHNIQUE: The operation began with a laparoscopic adhesiolysis to allow for identification of HAIP tubing (which was later removed) and placement of robotic ports. A peripheral liver biopsy was obtained to evaluate the degree of hepatic parenchymal fibrosis. Porta hepatic area was carefully exposed without causing an inadvertent injury to the surrounding hollow organs. Biopsy of perihepatic soft tissues was taken as appropriate to rule out any extrahepatic disease. The common bile duct and common hepatic duct with ERCP stents within it were identified with the use of ultrasonography. Anterior wall of the common hepatic duct was then opened, exposing the two plastic stents. Cephalad extension of the choledochotomy was made toward the biliary bifurcation and the right hepatic duct. The distal common bile duct was preserved for future endoscopic access to the biliary tree. After lowering the right-sided hilar plate, dense fibrosis around the right hepatic duct was divided sharply with robotic scissors, achieving a mechanical release of the dominant stricture. An intraoperative cholangioscopy was performed to confirm adequate openings of the right hepatic duct secondary and tertiary radicles, as well as patency of the left hepatic duct. A 4-Fr Fogarty catheter was used to sweep the potential biliary debris from within the right and left hepatic lobe. Finally, a confirmatory choledochoscopy was performed to ensure patency and clearance of the right-sided intrahepatic biliary ducts and the left hepatic duct before fashioning the hepaticojejunostomy. A 40-cm antecolic roux limb was next prepared for the RY hepaticojejunostomy. A side-to-side double staple technique was utilized to create the jejunojejunostomy. The common enterotomy was closed in a running watertight fashion. Once the roux limb was transposed to the porta hepatic in a tension-free manner, a side-to-side hepaticojejunostomy was constructed in a running fashion by using absorbable barbed sutures. The index suture was placed at 9 o'clock location, and the posterior wall of the anastomosis was run toward 3 o'clock location. This stabilized the roux limb to the bile duct. The anterior wall of the anastomosis was next fashioned by using a running technique from both corners of the anastomosis toward the middle (12 o'clock), where both sutures were tied together. This completed a wide side-to-side hepaticojejunostomy anastomosis encompassing the upper common hepatic duct, biliary bifurcation, and the right hepatic duct. A closed suction drain was placed before closing.5 RESULTS: The operative time was approximately 4 hr with 60 ml of blood loss. The postoperative course was uneventful. The patient was discharged home on postoperative Day 5 after removal of the closed suction drain, confirming the absence of bile leak. The patient had developed periportal/periductal fibrosis, cholestasis, and moderate-severe parenchymal fibrosis (F3-F4) based on liver biopsy, often seen in patients treated with a long course of floxuridine HAIP chemotherapy. The patient is clinically doing well at 1 year outpatient follow-up without any evidence of recurrent cholangitis at the time of this manuscript preparation. CONCLUSIONS: Robotic biliary stricturoplasty with RY hepaticojejunostomy for treatment of biliary sclerosis after HAIP chemotherapy is safe and feasible. Appropriate experience in minimally invasive hepatobiliary surgery is necessary to achieve this goal.


Subject(s)
Anastomosis, Roux-en-Y , Jejunostomy , Humans , Aged , Hepatic Artery/surgery , Robotic Surgical Procedures/methods , Infusions, Intra-Arterial , Antineoplastic Combined Chemotherapy Protocols/therapeutic use , Liver Neoplasms/secondary , Liver Neoplasms/surgery , Colorectal Neoplasms/pathology , Colorectal Neoplasms/surgery , Female , Constriction, Pathologic/etiology , Biliary Tract Surgical Procedures/methods , Dexamethasone/administration & dosage , Floxuridine/administration & dosage , Prognosis , Infusion Pumps
18.
Br J Surg ; 111(4)2024 Apr 03.
Article in English | MEDLINE | ID: mdl-38608150

ABSTRACT

BACKGROUND: Hepatic arterial infusion pump chemotherapy combined with systemic chemotherapy (HAIP-SYS) for liver-only colorectal liver metastases (CRLMs) has shown promising results but has not been adopted worldwide. This study evaluated the feasibility of HAIP-SYS in the Netherlands. METHODS: This was a single-arm phase II study of patients with CRLMs who received HAIP-SYS consisting of floxuridine with concomitant systemic FOLFOX or FOLFIRI. Main inclusion and exclusion criteria were borderline resectable or unresectable liver-only metastases, suitable arterial anatomy and no previous local treatment. Patients underwent laparotomy for pump implantation and primary tumour resection if in situ. Primary end point was feasibility, defined as ≥70% of patients completing two cycles of HAIP-SYS. Sample size calculations led to 31 patients. Secondary outcomes included safety and tumour response. RESULTS: Thirty-one patients with median 13 CRLMs (i.q.r. 6-23) were included. Twenty-eight patients (90%) received two HAIP-SYS cycles. Three patients did not get two cycles due to extrahepatic disease at pump placement, definitive pathology of a recto-sigmoidal squamous cell carcinoma, and progressive disease. Five patients experienced grade 3 surgical or pump device-related complications (16%) and 11 patients experienced grade ≥3 chemotherapy toxicity (38%). At first radiological evaluation, disease control rate was 83% (24/29 patients) and hepatic disease control rate 93% (27/29 patients). At 6 months, 19 patients (66%) had experienced grade ≥3 chemotherapy toxicity and the disease control rate was 79%. CONCLUSION: HAIP-SYS for borderline resectable and unresectable CRLMs was feasible and safe in the Netherlands. This has led to a successive multicentre phase III randomized trial investigating oncological benefit (EUDRA-CT 2023-506194-35-00). Current trial registration number: clinicaltrials.gov (NCT04552093).


Subject(s)
Carcinoma, Squamous Cell , Colorectal Neoplasms , Liver Neoplasms , Humans , Feasibility Studies , Liver Neoplasms/drug therapy , Liver Neoplasms/surgery , Infusion Pumps
19.
Enferm. nefrol ; 27(1): 56-61, ene.-mar. 2024. graf
Article in Spanish | IBECS | ID: ibc-232075

ABSTRACT

Introducción:Evaluar la prevalencia y el impacto del uso de líneas medias canalizadas por el Equipo de Infusión y Accesos Vasculares mediante punción eco-guiada comparada con la es-trategia endovenosa convencional (punción de catéter venoso periférico por enfermeras de hospitalización) en una unidad de nefrología y trasplante renal.Material y Método: Estudio observacional retrospectivo. Se compararon 3 periodos: pre-implantación, implantación y consolidación del Equipo de Infusión y Accesos Vasculares. Se incluyeron todos los pacientes ingresados en las unidades de hospitalización de Nefrología y Trasplante Renal que requirie-ron de la colocación de catéteres vasculares periféricos y línea media. Se analizó la prevalencia de acceso venoso, el tiempo de permanencia y los motivos de retirada (complicaciones).Resultados: La incidencia de los catéteres vasculares perifé-ricos fue decreciente mientras que el de las líneas medias se incrementó progresivamente en los tres períodos. Así mismo, no se observaron diferencias en el tiempo medio de perma-nencia de los catéteres vasculares periféricos mientras que la permanencia de días de la línea media se incrementó.Se confirma en todos los periodos una tasa de complicaciones más elevada y variable en los catéteres vasculares periféricos; mientras que en la línea media la tasa de complicaciones fue menor y más estable.Conclusiones: La implementación de un programa de terapia intravenosa en pacientes nefrológicos ha permitido minimizar el número de dispositivos venosos por paciente, con la conse-cuente reducción de punciones durante el ingreso, así como la disminución de las complicaciones asociadas a la canaliza-ción venosa (menor morbilidad).Palabras clave: Equipo de Infusión y Accesos Vasculares (EIAV); Líneas Medias (LM); Catéteres Vasculares Periféricos (CVP); complicaciones; paciente nefrológico. (AU)


Objective:To evaluate the prevalence and impact of midline catheters inserted by the Infusion and Vascular Access Team using echo-guided puncture compared to conventional intra-venous strategies (peripheral venous catheter insertion by hospitalization nurses) in a nephrology and kidney transplant unit.Material and Method: This is a retrospective observational study. Three periods were compared: pre-implementation, implementation, and consolidation of the Infusion and Vas-cular Access Team. All patients admitted to the Nephrology and Kidney Transplantation hospitalization units requiring the placement of peripheral vascular catheters and midline were included. The prevalence of venous access, dwell time, and reasons for removal (complications) were analyzed. Resultados: The incidence of peripheral vascular catheters decreased while that of midlines progressively increased in all three periods. Moreover, there were no differences in the mean dwell time of peripheral vascular catheters, whereas the dwell time of midlines increased. A higher and variable rate of complications was confirmed in peripheral vascular catheters in all periods, while in midlines, the complication rate was lower and more stable.Conclusions: Implementing an intravenous therapy program in nephrology patients has allowed for minimizing the num-ber of venous devices per patient, resulting in a reduction in punctures during hospitalization and a decrease in com-plications associated with venous cannulation (lower mor-bidity). (AU)


Subject(s)
Humans , Infusion Pumps , Punctures , Nephrology Nursing , Retrospective Studies , Spain , Catheterization, Peripheral
SELECTION OF CITATIONS
SEARCH DETAIL