Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 2.953
Filter
1.
Eur J Radiol ; 179: 111664, 2024 Oct.
Article in English | MEDLINE | ID: mdl-39121745

ABSTRACT

OBJECTIVES: To investigate whether high concentration iodinated contrast media (CM), compared with low concentration CM, could reduce pain and discomfort levels in patients who had level II and III venous conditions. METHODS: This prospective, single-center study enrolled patients who had level II and III venous conditions and underwent abdominal contrast-enhanced CT scan between July 2021 and February 2022. The venous condition to establish peripheral venous access for CM injection was graded using the Intravenous Access Scoring system, of which level II and III indicated poor venous condition and difficult venous access. Patients received iomeprol 400 in high concentration group and ioversol 320 in low group at an identical iodine delivery rate of 1.12 gI/s. The primary outcomes were pain and comfort levels. The secondary outcomes included adverse events and image quality. Patients rated pain intensity via Numerical Rating Scale and comfort level via Visual Analogue Scale with higher scores indicating higher levels of pain and discomfort. Quantitative and qualitative image assessment were compared between two groups. Continuous variables were compared using Student's t test or Mann-Whitney U test. Categorical variables were compared using χ2 test, χ2 test for trend or Fisher's exact test. RESULTS: A total of 206 patients (mean age, 60.13 ± 12.14 years; 81 males) were included with 99 in the high concentration group and 107 in the low concentration group. The high group had significantly lower pain scores (median 1 [IQR: 0-2] vs 2 (IQR 2-4), p < 0.001) and comfort scores (1 [IQR: 0-3] vs 3 [IQR: 2-5], p < 0.001) than the low group. Incidence of CM extravasation did not significantly differ (1.0 % vs 4.5 %, p = 0.214). No hypersensitivity reaction was observed. Qualitative assessment showed higher clarity scores of intrahepatic hepatic artery and portal vein in the high group. Quantitative assessment results were comparable between two groups. CONCLUSION: High concentration iodinated CM could lower pain intensity and improve comfort levels without comprising image quality of CT scan. High concentration CM is a preferable choice in patients with poor venous conditions during contrast-enhanced CT scan.


Subject(s)
Contrast Media , Iopamidol , Pain Measurement , Tomography, X-Ray Computed , Humans , Contrast Media/adverse effects , Contrast Media/administration & dosage , Female , Male , Middle Aged , Prospective Studies , Tomography, X-Ray Computed/methods , Iopamidol/analogs & derivatives , Iopamidol/administration & dosage , Iopamidol/adverse effects , Triiodobenzoic Acids/adverse effects , Triiodobenzoic Acids/administration & dosage , Aged , Radiography, Abdominal/methods , Abdominal Pain/diagnostic imaging , Abdominal Pain/prevention & control , Abdominal Pain/chemically induced
2.
Curr Med Imaging ; 20(1): e15734056306358, 2024.
Article in English | MEDLINE | ID: mdl-39051585

ABSTRACT

PURPOSE: This study aimed to evaluate the Pharmacovigilance (PV) and severity of hypersensitivity reactions induced by non-ionic Iodinated Contrast Media (ICM) in the radiology diagnosis reported to the United States Food and Drug Administration Adverse Event Reporting System (FAERS). METHODS: We retrospectively reviewed the reports of ICM-induced hypersensitivity reactions submitted to the FAERS database between January 2015 and January 2023 and conducted a disproportionality analysis. The seven most common non-ionic ICM, including iohexol, iopamidol, ioversol, iopromide, iomeprol, iobitridol, and iodixanol, were chiefly analyzed. Our primary endpoint was the PV of non-ionic ICM-induced total hypersensitivity events. STATA 17.0 MP was used for statistical analysis. RESULTS: In total, 35357 reports of adverse reaction events in radiology diagnosis were retrieved from the FAERS database. Among them, 6181 reports were on hypersensitivity reaction events (mean age: 57.1 ± 17.8 years). The hypersensitivity reaction-related PV signal was detected for iohexol, ioversol, iopromide, iomeprol, iobitridol, and iodixanol, but not for iopamidol. The proportion of iomeprol-induced hypersensitivity reactions and the probability of ioversol-induced severe hypersensitivity reactions have been found to be significantly increased. CONCLUSION: The probability and severity of hypersensitivity reaction events in non-ionic ICM are different. Iohexol, ioversol, iopromide, iomeprol, iobitridol, and iodixanol have higher risks compared to iopamidol. In addition, the constituent ratio of hypersensitivity reactions induced by iomeprol is significantly increased, and the associated probability induced by ioversol is significantly increased.


Subject(s)
Contrast Media , Drug Hypersensitivity , Iohexol , Iopamidol , Triiodobenzoic Acids , Humans , Contrast Media/adverse effects , Middle Aged , Female , Drug Hypersensitivity/epidemiology , Male , Retrospective Studies , Triiodobenzoic Acids/adverse effects , Iopamidol/adverse effects , Iopamidol/analogs & derivatives , Iohexol/adverse effects , Iohexol/analogs & derivatives , United States , Aged , Adult , Databases, Factual , Pharmacovigilance , Adverse Drug Reaction Reporting Systems , United States Food and Drug Administration
3.
J Allergy Clin Immunol Pract ; 12(3): 705-713.e6, 2024 Mar.
Article in English | MEDLINE | ID: mdl-39056227

ABSTRACT

BACKGROUND: Two-dimensional (2D) classifications of iodinated contrast media (ICM) are insufficient to explain the observed skin test (ST) reactivity patterns in patients with drug hypersensitivity reactions (DHRs) to ICM. OBJECTIVE: To refine the current view on allergic DHRs to ICM by analyzing ST reactivity patterns in patients with previous reactions to ICM. METHODS: Patients with a history of DHR to ICM and positive STs, who presented at the University Hospital of Montpellier between 2004 and 2022, were included in the study. The relative difference between every two ICM products was measured by Manhattan distance and odds ratios were computed for all pairs of products in the immediate reaction (IR) and non-immediate reaction (NIR) ST groups. RESULTS: A total of 181 patients were included in the study. Odds ratio analysis identified significant associations between classical cross-reactive ICM, such as iohexol-ioversol, iohexol-iomeprol, iomeprol-ioversol, and iohexol-iodixanol in the IR ST group and iohexol-ioversol, iopromide-iohexol, and iomeprol-ioversol in the NIR ST group. We also identified uncommon associations, such as ioxitalamate-amidotrizoate in the IR ST group and amidotrizoate-iopamidol and amidotrizoate-ioxitalamate in the NIR ST group. The results were reflected by the Manhattan distance, which suggested the existence of clusters containing the same classically associated ICM as well as uncommon associations, which we hypothesize to be related to similarities in the 3D structure of the respective ICM. CONCLUSIONS: Current chemical (2D) classifications cannot explain all observed ST reactivity patterns. Whether the 3D structure can be integrated into the current classifications to interpret the observed ST reactivity patterns and predict tolerance to alternative ICM requires further research.


Subject(s)
Contrast Media , Drug Hypersensitivity , Iohexol , Iopamidol , Skin Tests , Triiodobenzoic Acids , Humans , Contrast Media/adverse effects , Drug Hypersensitivity/diagnosis , Drug Hypersensitivity/epidemiology , Female , Male , Middle Aged , Iopamidol/adverse effects , Iopamidol/analogs & derivatives , Triiodobenzoic Acids/adverse effects , Adult , Iohexol/adverse effects , Iohexol/analogs & derivatives , Aged , Iodine Compounds/adverse effects
4.
Radiography (Lond) ; 30(4): 1080-1084, 2024 07.
Article in English | MEDLINE | ID: mdl-38772064

ABSTRACT

INTRODUCTION: Exposure of iodinated contrast media (ICM) to X-rays is not uncommon, as contrast media are often stored in close proximity to radiological equipment. However, the interaction between X-rays and ICM is not widely investigated in literature. The present study aims to investigate the chemical stability of iomeprol and iopamidol, two commercial iodinated ICM commonly used in diagnostic imaging, under X-rays exposure. METHODS: Different formulations of iopamidol and iomeprol (iodine concentration 9 to 400 mgI/mL, volume 50-500 mL) were exposed to three different conditions of X-ray irradiation: i) 1 month storage in CT room (≈5-15 mGy); (ii) low-dose protocol (≈10 mGy); (ii) stressed protocol (≈100 mGy). Unexposed and exposed solutions were characterized by high-performance liquid chromatography in terms of concentration of active pharmaceutical ingredient (API), iodine species and by products. In addition, appearance and colour of the solutions were inspected and pH measured. RESULTS: API concentrations, appearance, colour and pH of the exposed formulations remained unaffected by X-rays. Measured concentrations of iodine species and by products were observed well within the acceptability criteria, i.e. values turned out to be lower than specifications limits established by the manufacturer, considering both release and shelf-life values. CONCLUSIONS: Up to 100 mGy X-ray exposure did not induce any alteration of iomeprol and iopamidol formulation, nor a detectable increase in the concentration of iodine species or by-products. IMPLICATIONS FOR PRACTICE: Our study strengthens the hypothesis that ICM are stable under X-rays exposure up to 100 mGy.


Subject(s)
Contrast Media , Drug Stability , Iopamidol , Iopamidol/analogs & derivatives , Iopamidol/chemistry , X-Rays , Chromatography, High Pressure Liquid , Humans
5.
BMC Pulm Med ; 24(1): 198, 2024 Apr 22.
Article in English | MEDLINE | ID: mdl-38649880

ABSTRACT

BACKGROUND: Iopamidol is a non-ionic, water-soluble iodine contrast agent that is considered safe for intravenous or intra-arterial administration and is widely used both in the general population and in patients undergoing oncological treatment. While adverse reactions to iopamidol have been documented, to date, no pulmonary and gastric hemorrhages induced by iopamidol have been reported in oncology patients. We report the first case of this complication. CASE PRESENTATION: We report the case of a 60-year-old woman with marginal zone lymphoma who was receiving antineoplastic therapy. As part of the investigation for the condition, she underwent chest enhancement CT with iopamidol. Shortly thereafter(within five minutes), she experienced hemoptysis and hematemesis. She was intubated and admitted to the intensive care unit. Pre- and post-contrast images demonstrated the course of the hemorrhage. Flexible bronchoscopy and gastroscopy on the following day showed no active bleeding, and the patient recovered completely after antiallergy treatment. We speculate that contrast-induced hypersensitivity was the most likely cause of the transient pulmonary and gastric bleeding. CONCLUSION: Although rare, the complications of iopamidol, which may cause allergic reactions in the lungs and stomach, should be considered.


Subject(s)
Contrast Media , Hemoptysis , Iopamidol , Lymphoma, B-Cell, Marginal Zone , Tomography, X-Ray Computed , Humans , Female , Middle Aged , Contrast Media/adverse effects , Lymphoma, B-Cell, Marginal Zone/drug therapy , Lymphoma, B-Cell, Marginal Zone/complications , Iopamidol/adverse effects , Iopamidol/administration & dosage , Hemoptysis/chemically induced , Gastrointestinal Hemorrhage/chemically induced , Lung Diseases/chemically induced , Bronchoscopy , Hematemesis/chemically induced
6.
Molecules ; 29(7)2024 Mar 27.
Article in English | MEDLINE | ID: mdl-38611760

ABSTRACT

A multi-residue UHPLC-MS/MS analytical method, previously developed for monitoring 52 pharmaceuticals in drinking water, was used to analyse these pharmaceuticals in wastewater originating from healthcare facilities in the Czech Republic. Furthermore, the methodology was expanded to include the evaluation of the effectiveness of drug removal in Czech wastewater treatment plants (WWTPs). Of the 18 wastewater samples analysed by the validated UHPLC-MS/MS, each sample contained at least one quantifiable analyte. This study reveals the prevalence of several different drugs; mean concentrations of 702 µg L-1 of iomeprol, 48.8 µg L-1 of iopromide, 29.9 µg L-1 of gabapentin, 42.0 µg L-1 of caffeine and 82.5 µg L-1 of paracetamol were present. An analysis of 20 samples from ten WWTPs revealed different removal efficiencies for different analytes. Paracetamol was present in the inflow samples of all ten WWTPs and its removal efficiency was 100%. Analytes such as caffeine, ketoprofen, naproxen or atenolol showed high removal efficiencies exceeding 80%. On the other hand, pharmaceuticals like furosemide, metoprolol, iomeprol, zolpidem and tramadol showed lower removal efficiencies. Four pharmaceuticals exhibited higher concentrations in WWTP effluents than in the influents, resulting in negative removal efficiencies: warfarin at -9.5%, indomethacin at -53%, trimethoprim at -54% and metronidazole at -110%. These comprehensive findings contribute valuable insights to the pharmaceutical landscape of wastewater from healthcare facilities and the varied removal efficiencies of Czech WWTPs, which together with the already published literature, gives a more complete picture of the burden on the aquatic environment.


Subject(s)
Acetaminophen , Cosmetics , Iopamidol/analogs & derivatives , Humans , Caffeine , Chromatography, High Pressure Liquid , Tandem Mass Spectrometry , Wastewater , Pharmaceutical Preparations
7.
Article in English | MEDLINE | ID: mdl-38272634

ABSTRACT

5-Aminoisophthalic acid and 5-nitroisophthalic acid (5-NIPA) are potential impurities in preparations of 5-amino-2,4,6-triiodoisophthalic acid, which is a key intermediate in the synthesis of the iodinated contrast agent iopamidol. We have studied their mutagenicity in silico (quantitative structure-activity relationships, QSAR) and by the bacterial reverse mutation assay (Ames test). First, the compounds were screened with the tools Derek Nexus™ and Leadscope®. Both compounds were flagged as potentially mutagenic (class 3 under ICH M7). However, contrary to the in silico prediction, neither chemical was mutagenic in the Ames test (plate incorporation method) with or without S9 metabolic activation.


Subject(s)
Contrast Media , Mutagens , Mutagens/toxicity , Mutagens/chemistry , Contrast Media/toxicity , Iopamidol/toxicity , Computer Simulation , Mutagenicity Tests/methods
9.
J Vasc Interv Radiol ; 35(3): 462-468, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38007178

ABSTRACT

PURPOSE: To compare 2 ratios of n-butyl-2-cyanoacrylate (nBCA)-ethiodized oil (Lipiodol)-iopamidol (NLI) in balloon-assisted portal vein embolization (PVE) in swine. MATERIALS AND METHODS: In an in vitro study, NLI prepared at a ratio of 2:3:1 (NLI231) or 1:4:1 (NLI141) was injected into 2.5- or 10-mL syringes filled with swine blood, and the viscosity of NLI was measured to determine an appropriate balloon occlusion time. Two portal vein branches in 8 female swine (n = 16 vein branches) were embolized with NLI231 (n = 8) or NLI141 (n = 8) under balloon occlusion. Portal venography was performed before, immediately after, and 3 days after PVE to evaluate the migration of NLI and the recanalization of embolized portal vein branches. Then, the livers were removed for histopathologic evaluation. RESULTS: The times to peak viscosity of NLI231 in the 2.5- and 10-mL syringes were 55.8 seconds (SD ± 7.0) and 85.2 seconds (SD ± 6.3), and those to peak viscosity of NLI141 were 129.2 seconds (SD ± 11.8) and 254.0 seconds (SD ± 21.8), respectively. No migration of NLI231 was observed in all 8 procedures immediately or 3 days after PVE. Migration of NLI141 was observed in 6 of 8 procedures within 3 days after PVE. The migration frequency of the embolic material was lower in the NI231 group than in the NLI141 group (0/8 vs 6/8; P = .051). Histologically, NLI231 occupied the portal veins without any thrombi, whereas NLI141 was accompanied by thrombi in the portal veins. CONCLUSIONS: NLI231 may be more suitable than NLI141 for balloon-assisted PVE in swine.


Subject(s)
Embolization, Therapeutic , Enbucrilate , Female , Animals , Swine , Portal Vein/diagnostic imaging , Portal Vein/pathology , Ethiodized Oil , Iopamidol , Liver/pathology , Embolization, Therapeutic/methods
10.
Huan Jing Ke Xue ; 44(12): 6811-6822, 2023 Dec 08.
Article in Chinese | MEDLINE | ID: mdl-38098406

ABSTRACT

NaHCO3-activated buckwheat biochar was studied, and an optimal biochar of 0.25N-BC [m(NaHCO3):m(buckwheat bark)=0.25:1]was selected. SEM, BET, XRD, Raman, FTIR, and XPS methods were applied to analyze the effects of NaHCO3 on the physicochemical properties of buckwheat biochar. The adsorption properties and mechanism of NaHCO3-activated buckwheat biochar for iopamidol(IPM), a nonionic iodol X-ray contrast agent, were also investigated. The results showed that compared with buckwheat skin biochar(BC), NaHCO3-activated biochar had higher structural defects(surface area and pore volume increased, respectively, from 480.40 m2·g-1 and 0.29 cm3·g-1 to 572.83 m2·g-1 and 0.40 cm3·g-1, with ID/IG being 1.22 times that of BC), the carbon and oxygen functional groups on the BC surface changed significantly, and the polarity increased [(N+O)/C from 0.15 to 0.24]. The maximum adsorption capacity of 0.25N-BC for IPM was 74.94 mg·g-1, which was 9.51 times that of BC(7.88 mg·g-1). The pseudo-second-order adsorption kinetics and Langmuir and Freundlich isotherm models could well fit the adsorption of 0.25N-BC for IPM. The adsorption processes were mainly chemical, monolayer, and heterogeneous multilayer adsorption. Pore filling, hydrogen bonding, π-π, and n-π interactions were the main mechanisms of 0.25N-BC adsorption for IPM. Comparing the activated buckwheat biochar by different bases [KOH, Na2CO3, NaHCO3, KHCO3, and Ca(HCO3)2], 0.25N-BC exhibited high adsorption capability and short equilibrium time and could effectively remove the IPM residue in the actual water(secondary sedimentation tank effluent and lake). The removal rate of IPM remained at 74.91% after three adsorption-desorption cycles. The results showed that NaHCO3-activated buckwheat biochar was a green, effective, and sustainable adsorbent for the removal of iodine-containing organic matter.


Subject(s)
Fagopyrum , Water Pollutants, Chemical , Iopamidol , Adsorption , Water Pollutants, Chemical/analysis , Charcoal/chemistry , Kinetics
11.
Cardiovasc Intervent Radiol ; 46(11): 1632-1640, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37759091

ABSTRACT

PURPOSE: To examine the characteristics of drug-loaded superabsorbent polymer microspheres (SAP-MS) such as drug absorption, drug release, diameter, and visibility. MATERIALS AND METHODS: SAP-MS (HepaSphere150-200 µm; Merit Medical, South Jordan, UT, USA) were suspended in drug solutions: (a) cefazolin, (b) lidocaine, (c) iopamidol and cefazolin, (d) iopamidol and lidocaine, and (e) iopamidol, cefazolin, and lidocaine. The concentrations of drugs were measured, and the amount of each drug absorbed was calculated. Filtered drug-loaded SAP-MS were mixed with saline, and the drug release rates were calculated. The diameter changes of SAP-MS during absorption were observed. Radiography of drug-loaded SAP-MS was evaluated as radiopacity by contrast-to-noise ratio (CNR). RESULTS: The drug concentration did not change during absorption. The release rates increased for 10 min and then came to an equilibrium. The mean amounts of drug absorbed at 180 min and mean release rates at 24 h were (a) cefazolin: 265.4 mg, 64.2%; (b) lidocaine: 19.6 mg, 75.6%; (c) iopamidol: 830.2 mg, 22.5%; cefazolin: 137.6 mg, 21.2%; (d) iopamidol: 1620.6 mg, 78.5%; lidocaine: 13.5 mg, 81.4%; and (e) iopamidol: 643.7 mg, 52.9%; cefazolin: 194.0 mg, 51.6%; lidocaine: 5.3 mg, 58.4%. The diameter of SAP-MS increased for approximately 15 min. Finally, the diameters of SAP-MS were (a) 3.9 times, (b) 5.0 times, (c) 2.2 times, (d) 5.5 times, and (e) 3.6 times larger than the original size. Drug-loaded SAP-MS containing iopamidol were visible under X-ray imaging, with CNRs of (c) 3.0, (d) 9.0, and (e) 4.5. CONCLUSION: SAP-MS can absorb and release iopamidol, cefazolin, and lidocaine.


Subject(s)
Anti-Bacterial Agents , Contrast Media , Humans , Iopamidol , Cefazolin , Microspheres , Polymers , Lidocaine , Analgesics
12.
J Neuroimaging ; 33(6): 909-916, 2023.
Article in English | MEDLINE | ID: mdl-37626255

ABSTRACT

BACKGROUND AND PURPOSE: Several studies in the literature have attempted to subjectively assess the degree of visualization of different neurovascular structures using different contrast agents and concentrations. Given the recent contrast shortages, we aim to objectively compare the radiopacity achieved with four angiographic contrast agents used in clinical practice. METHODS: Isovue 370, Visipaque 320, Omnipaque 300, and Isovue 300 were each drawn up at 25%, 50%, 75%, and 100% concentrations and compared against normal saline and air syringes. CT scans were obtained, and regions of interest were analyzed for radiopacity using Hounsfield unit (HU) measurements. An aneurysm model with different contrast concentrations was also scanned and dimensions compared. Two-tailed t-tests and Cohen's d coefficients were applied to assess for differences in mean HU measurements. RESULTS: Isovue 370 and Isovue 300 had the highest and lowest mean HU, respectively (p < .001). Visipaque 320 at 25% concentration had the lowest mean HU at -.76. Statistically similar agents (p < .05) were Visipaque 320 and Omnipaque 300 at a 100% concentration (p = .30), and Omnipaque 300 and Isovue 300 at a 25% concentration (p = .73). Aneurysm dimensions among Isovue 370, Visipaque 320, and Omnipaque 300 were all similar, whereas with Isovue 300, the dimensions were significantly smaller (p < .05). CONCLUSION: Isovue 370 provides the highest HU radiopacity and the most accurate aneurysm measurements. Angiographic measurements obtained with Isovue 300 may underestimate the actual aneurysmal dimensions. Visipaque 320 and Omnipaque 300 at 100% concentration have similar mean HUs and are beneficial for patients with chronic kidney or cardiac disease.


Subject(s)
Aneurysm , Contrast Media , Humans , Iopamidol , Iohexol , Tomography, X-Ray Computed/methods
13.
J Mater Chem B ; 11(31): 7435-7441, 2023 08 09.
Article in English | MEDLINE | ID: mdl-37435712

ABSTRACT

Peptide-based hydrogels have been recently investigated as materials for biomedical applications like tissue engineering and delivery of drugs and imaging agents. Among the synthetic peptide hydrogelators, the cationic hexapeptides Ac-K1 and Ac-K2 were proposed as scaffolds for bioprinting applications. Here, we report the formulation of Ac-K1 and Ac-K2 hydrogels loaded with iopamidol, an iodinated contrast agent clinically approved for X-ray computed tomography, and more recently identified as an efficient CEST-MRI probe. Iopamidol-loaded hydrogels were soft, injectable and non-toxic both in vitro (on three tumor cell lines: GL261, TS/A and 3T3-NIH) and in vivo (in Balb/c mice inoculated with TS/A breast cancer cells). The in vitro CEST-MRI study evidenced the typical features of the CEST pattern of iopamidol, with a CEST contrast higher than 50%. Due to their injectability and good ability to retain the contrast agent, the herein investigated systems can be considered as promising candidates for the development of smart MRI detectable hydrogels.


Subject(s)
Contrast Media , Iopamidol , Mice , Animals , Hydrogels , Magnetic Resonance Imaging/methods , Peptides
14.
Can J Vet Res ; 87(3): 217-223, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37397633

ABSTRACT

The objective of this study was to compare the rostral spread of lumbosacral epidural volumes of a mixture of dye and contrast medium, calculated using body weight (BW) or vertebral column length (LE), in 22 dog cadavers. The dogs weighed 4.6 to 52.0 kg. Dogs were paired within a < 10% difference for BW and LE and with the same body condition score (BCS). Pairs of dogs were injected while in sternal recumbency through an epidural catheter with a volume mixture of iopamidol and dye, calculated based on BW: 0.2 mL/kg in one of the cadavers and based on LE: 0.05 mL/cm (< 50 cm), 0.07 mL/cm (50 to < 70 cm), 0.08 mL/cm (70 to < 80 cm), and 0.11 mL/cm (≥ 80 cm) in the other cadaver. The extent of rostral spread was determined using computed tomography for iopamidol and anatomical dissection for dye. Comparisons for dye and iopamidol within each dog, and for BW and LE within matched pairs, were completed with mixed linear models (P < 0.05). The number of vertebrae reached by dye was greater than the number reached by iopamidol in both BW and LE, but the rostral spread was not significantly different between BW and LE for all pairs. In conclusion, dye tends to spread further than iopamidol and therefore, these two methods should not be considered interchangeable when used in research studies.


L'objectif de cette étude était de comparer l'étalement rostral des volumes épiduraux lombo-sacrés d'un mélange de colorant et de produit de contraste, calculé en utilisant le poids corporel (PC) ou la longueur de la colonne vertébrale (LE), chez 22 cadavres de chiens. Les chiens pesaient de 4,6 à 52,0 kg. Les chiens ont été appariés avec une différence < 10 % pour PC et LE et avec le même score d'état corporel (PCS). Des paires de chiens ont reçu une injection alors qu'ils étaient en décubitus sternal à travers un cathéter péridural avec un mélange volumique d'iopamidol et de colorant, calculé sur la base du poids corporel : 0,2 mL/kg dans l'un des cadavres et sur la base de la LE : 0,05 mL/cm (< 50 cm), 0,07 mL/cm (50 à < 70 cm), 0,08 mL/cm (70 à < 80 cm) et 0,11 mL/cm (≥ 80 cm) dans l'autre cadavre. L'étendue de la propagation rostrale a été déterminée par tomodensitométrie pour l'iopamidol et dissection anatomique pour le colorant. Les comparaisons pour le colorant et l'iopamidol au sein de chaque chien, et pour PC et LE au sein de paires appariées, ont été complétées avec des modèles linéaires mixtes (P < 0,05). Le nombre de vertèbres atteintes par le colorant était supérieur au nombre atteint par l'iopamidol dans PC et LE, mais la propagation rostrale n'était pas significativement différente entre PC et LE pour toutes les paires. En conclusion, le colorant a tendance à se propager plus loin que l'iopamidol et, par conséquent, ces deux méthodes ne doivent pas être considérées comme interchangeables lorsqu'elles sont utilisées dans des études de recherche.(Traduit par Docteur Serge Messier).


Subject(s)
Dog Diseases , Iopamidol , Dogs , Animals , Spine , Cadaver , Body Weight , Tomography, X-Ray Computed/veterinary
15.
Can J Vet Res ; 87(3): 208-216, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37397637

ABSTRACT

The first objective of this prospective, randomized, crossover experimental trial was to compare the rostral spread of lumbosacral epidural volume calculated by body weight (BW) or vertebral column length (LE) in 6 small, isoflurane-anesthetized female beagle dogs (BW: 7.5 to 10.2 kg; LE measured from the occipital crest to the sacrococcygeal space: 46 to 56 cm). The second objective was to assess the response to a noxious stimulus once the dogs recovered from anesthesia and to determine the effects of the injection on cardiopulmonary variables. While in sternal position, dogs were injected through an epidural catheter with a volume mixture of bupivacaine 0.25% and iopamidol 15% based on BW: 0.2 mL/kg or LE: 0.05 mL/cm (< 50 cm) or 0.07 mL/cm (50 to < 70 cm). Rostral spread was determined by counting the number of vertebrae reached by iopamidol using computed tomography. After anesthesia, cardiopulmonary variables, motor function, and responses to nociceptive stimuli were evaluated. Comparisons were completed with mixed linear models and 2-way analysis of variance (ANOVA) (P < 0.05). The volume of injectate (3.29 ± 0.74 versus 1.81 ± 0.21 mL; mean ± SD) and the number of vertebrae (22 ± 2 versus 19 ± 2 vertebrae) reached by iopamidol were significantly greater for LE than for BW. Response to nociception, time to return of pain sensation, motor function, and cardiopulmonary variables were similar between groups. In conclusion, dosing based on LE resulted in larger rostral spread than when based on BW in dogs of small size.


Le premier objectif de cet essai expérimental croisé prospectif randomisé était de comparer la propagation rostrale du volume épidural lombo-sacré calculé en fonction du poids corporel (PC) ou de la longueur de la colonne vertébrale (LE) chez 6 petites chiennes beagle anesthésiées à l'isoflurane (PC : 7,5 à 10,2 kg; LE mesuré de la crête occipitale à l'espace sacro-coccygien : 46 à 56 cm). Le deuxième objectif était d'évaluer la réponse à un stimulus nocif une fois que les chiens se sont remis de l'anesthésie et de déterminer les effets de l'injection sur les variables cardiopulmonaires. En position sternale, les chiens ont reçu une injection via un cathéter péridural d'un mélange volumique de bupivacaïne à 0,25 % et d'iopamidol à 15 % basé sur le poids corporel : 0,2 mL/kg ou LE : 0,05 mL/cm (< 50 cm) ou 0,07 mL/cm (50 à < 70 cm). La propagation rostrale a été déterminée en comptant le nombre de vertèbres atteintes par l'iopamidol en utilisant la tomodensitométrie. Après l'anesthésie, les variables cardiopulmonaires, la fonction motrice et les réponses aux stimuli nociceptifs ont été évaluées. Les comparaisons ont été complétées avec des modèles linéaires mixtes et une analyse de variance à 2 facteurs (ANOVA) (P < 0,05). Le volume d'injectat (3,29 ± 0,74 versus 1,81 ± 0,21 mL; moyenne ± SD) et le nombre de vertèbres (22 ± 2 versus 19 ± 2 vertèbres) atteints par l'iopamidol étaient significativement plus élevés pour LE que pour BW. La réponse à la nociception, le temps de retour de la sensation de douleur, la fonction motrice et les variables cardiopulmonaires étaient similaires entre les groupes. En conclusion, le dosage basé sur LE a entraîné une plus grande propagation rostrale que lorsqu'il était basé sur BW chez les chiens de petite taille.(Traduit par Docteur Serge Messier).


Subject(s)
Anesthesia, Epidural , Iopamidol , Dogs , Animals , Female , Injections, Epidural/veterinary , Prospective Studies , Anesthesia, Epidural/veterinary , Spine , Body Weight
16.
NMR Biomed ; 36(10): e4986, 2023 10.
Article in English | MEDLINE | ID: mdl-37280721

ABSTRACT

Tumor acidosis is an important biomarker for aggressive tumors, and extracellular pH (pHe) of the tumor microenvironment can be used to predict and evaluate tumor responses to chemotherapy and immunotherapy. AcidoCEST MRI measures tumor pHe by exploiting the pH-dependent chemical exchange saturation transfer (CEST) effect of iopamidol, an exogenous CT agent repurposed for CEST MRI. However, all pH fitting methodologies for acidoCEST MRI data have limitations. Herein we present results of the application of machine learning for extracting pH values from CEST Z-spectra of iopamidol. We acquired 36,000 experimental CEST spectra from 200 phantoms of iopamidol prepared at five concentrations, five T1 values, and eight pH values at five temperatures, acquired at six saturation powers and six saturation times. We also acquired T1 , T2 , B1 RF power, and B0 magnetic field strength supplementary MR information. These MR images were used to train and validate machine learning models for the tasks of pH classification and pH regression. Specifically, we tested the L1-penalized logistic regression classification (LRC) model and the random forest classification (RFC) model for classifying the CEST Z-spectra for thresholds at pH 6.5 and 7.0. Our results showed that both RFC and LRC were effective for pH classification, although the RFC model achieved higher predictive value, and improved the accuracy of classification accuracy with CEST Z-spectra with a more limited set of saturation frequencies. Furthermore, we used LASSO and random forest regression (RFR) models to explore pH regression, which showed that the RFR model achieved higher accuracy and precision for estimating pH across the entire pH range of 6.2-7.3, especially when using a more limited set of features. Based on these results, machine learning for analysis of acidoCEST MRI is promising for eventual in vivo determination of tumor pHe.


Subject(s)
Iopamidol , Neoplasms , Humans , Hydrogen-Ion Concentration , Magnetic Resonance Imaging/methods , Machine Learning , Tumor Microenvironment
17.
Eur J Radiol ; 164: 110880, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37187078

ABSTRACT

PURPOSE: To evaluate the clinical features and risk factors of iodinated contrast media (ICM)-induced anaphylaxis. METHODS: This retrospective study included all patients undergoing contrast-enhanced computed tomography (CT) with intravenous ICM administration (iopamidol, iohexol, iomeprol, iopromide, ioversol) at our hospital between April 2016 and September 2021. Medical records of patients who experienced anaphylaxis were reviewed, and the multivariable regression model using generalized estimating equations was employed to eliminate the effect of intrapatient correlation. RESULTS: Of the 76,194 ICM administrations (44,099 men [58 %] and 32,095 women; age, median, 68 years) to 27, 696 patients, anaphylaxis occurred in 45 cases in 45 different patients (0.06 % of administration and 0.16 % of patients), all with onset within 30 min after administration. Thirty-one (69 %) had no risk factors for ADRs, including 14 (31 %) who had previously used the same ICM that caused anaphylaxis. Thirty-one patients (69 %) had a history of ICM use without any ADRs. Four patients (8.9 %) received oral steroid premedication. The only factor associated with anaphylaxis was the type of ICM, with an odds ratio (OR) of 6.8 (p < 0.001) for iomeprol with iopamidol as a reference. No significant differences in OR of anaphylaxis were found for patients' age, sex, or premedication. CONCLUSION: The overall incidence of anaphylaxis due to ICM was very low. More than half of the cases had no risk factors for ADRs and had no ADRs on past ICM administration, although the ICM type was associated with a higher OR.


Subject(s)
Anaphylaxis , Drug-Related Side Effects and Adverse Reactions , Male , Humans , Female , Aged , Contrast Media/adverse effects , Iopamidol/adverse effects , Anaphylaxis/chemically induced , Anaphylaxis/epidemiology , Retrospective Studies
18.
J Appl Physiol (1985) ; 134(6): 1496-1507, 2023 06 01.
Article in English | MEDLINE | ID: mdl-37167261

ABSTRACT

Pulmonary perfusion has been poorly characterized in acute respiratory distress syndrome (ARDS). Optimizing protocols to measure pulmonary blood flow (PBF) via dynamic contrast-enhanced (DCE) computed tomography (CT) could improve understanding of how ARDS alters pulmonary perfusion. In this study, comparative evaluations of injection protocols and tracer-kinetic analysis models were performed based on DCE-CT data measured in ventilated pigs with and without lung injury. Ten Yorkshire pigs (five with lung injury, five healthy) were anesthetized, intubated, and mechanically ventilated; lung injury was induced by bronchial hydrochloric acid instillation. Each DCE-CT scan was obtained during a 30-s end-expiratory breath-hold. Reproducibility of PBF measurements was evaluated in three pigs. In eight pigs, undiluted and diluted Isovue-370 were separately injected to evaluate the effect of contrast viscosity on estimated PBF values. PBF was estimated with the peak-enhancement and the steepest-slope approach. Total-lung PBF was estimated in two healthy pigs to compare with cardiac output measured invasively by thermodilution in the pulmonary artery. Repeated measurements in the same animals yielded a good reproducibility of computed PBF maps. Injecting diluted isovue-370 resulted in smaller contrast-time curves in the pulmonary artery (P < 0.01) and vein (P < 0.01) without substantially diminishing peak signal intensity (P = 0.46 in the pulmonary artery) compared with the pure contrast agent since its viscosity is closer to that of blood. As compared with the peak-enhancement model, PBF values estimated by the steepest-slope model with diluted contrast were much closer to the cardiac output (R2 = 0.82) as compared with the peak-enhancement model. DCE-CT using the steepest-slope model and diluted contrast agent provided reliable quantitative estimates of PBF.NEW & NOTEWORTHY Dynamic contrast-enhanced CT using a lower-viscosity contrast agent in combination with tracer-kinetic analysis by the steepest-slope model improves pulmonary blood flow measurements and assessment of regional distributions of lung perfusion.


Subject(s)
Lung Injury , Respiratory Distress Syndrome , Animals , Swine , Contrast Media , Iopamidol , Reproducibility of Results , Kinetics , Lung/diagnostic imaging , Tomography, X-Ray Computed/methods , Perfusion
19.
Chemosphere ; 333: 138885, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37209847

ABSTRACT

The COVID-19 pandemic resulted in increasing the usage of iodinated contrast media (ICM), and thus an increase in the prevalence of ICM-contaminated wastewater. While ICM is generally safe, this has the potential to be problematic because as medical wastewater is treated and disinfected, various ICM-derived disinfection byproducts (DBPs) may be generated and released into the environment. However, little information was available about whether ICM-derived DBPs are toxic to aquatic organisms. In this study, the degradation of three typical ICM (iopamidol, iohexol, diatrizoate) at initial concentration of 10 µM and 100 µM in chlorination and peracetic acid without or with NH4+ was investigated, and the potential acute toxicity of treated disinfected water containing potential ICM-derived DBPs on Daphnia magna, Scenedesmus sp. and Danio rerio was tested. The degradation results suggested that only iopamidol was significantly degraded (level of degradation >98%) by chlorination, and the degradation rate of iohexol and diatrizoate were significantly increased in chlorination with NH4+. All three ICM were not degraded in peracetic acid. The toxicity analysis results indicate that only the disinfected water of iopamidol and iohexol by chlorination with NH4+ were toxic to at least one aquatic organism. These results highlighted that the potential ecological risk of ICM-contained medical wastewater by chlorination with NH4+ should not be neglected, and peracetic acid may be an environment-friendly alternative for the disinfection of wastewater containing ICM.


Subject(s)
COVID-19 , Iodine Compounds , Scenedesmus , Water Pollutants, Chemical , Animals , Humans , Iohexol/toxicity , Iohexol/analysis , Iopamidol , Disinfection/methods , Diatrizoate/analysis , Daphnia , Zebrafish , Peracetic Acid , Wastewater/toxicity , Pandemics , Contrast Media/toxicity , Contrast Media/analysis , Water/analysis , Water Pollutants, Chemical/toxicity , Water Pollutants, Chemical/analysis , Halogenation
20.
J Cardiol ; 82(3): 194-200, 2023 09.
Article in English | MEDLINE | ID: mdl-37209906

ABSTRACT

BACKGROUND: Optical coherence tomography (OCT) is becoming the standard imaging modality for percutaneous coronary intervention (PCI) because of its high resolution. To perform appropriate OCT-guided PCI, it is necessary to avoid artefacts and obtain high-quality images. We investigated the relationship between artefacts and the viscosity of contrast media, which were used to remove air before OCT imaging catheter was inserted into guiding catheter. METHODS: We retrospectively analyzed every pullback of OCT examinations from January 2020 to September 2021. Cases were divided into two groups according to the type of contrast media used for catheter flushing: low-viscosity (Iopamidol-300, Bayer, Nordrhein-Westfalen, Germany) vs. high-viscosity (Iopamidol-370, Bayer). We evaluated the artefacts and quality of each OCT image and performed ex vivo experiments to compare differences in artefact frequencies using the two contrast media. RESULTS: A total of 140 pullbacks in the low-viscosity group and 73 pullbacks in the high-viscosity group were analyzed. The percentage of grade 2 and 3 images (with good quality) in the low-viscosity group was significantly lower (68.1 % vs. 94.5 %, p < 0.001). Rotational artefacts were significantly more common in the low-viscosity group (49.3 % vs. 8.2 %, p < 0.001). In multivariate analysis, using low-viscosity contrast media was a significant factor influencing the appearance of rotational artefacts and affecting image quality (odds ratio, 9.42; 95 % confidence interval, 3.58 to 24.8; p < 0.001). In ex vivo experiments, using low-viscosity contrast media was also a significant predictor of artefact occurrence during OCT (p < 0.01). CONCLUSIONS: The viscosity of the contrast agent used while flushing the OCT imaging catheter contributes to the appearance of OCT artefacts.


Subject(s)
Coronary Artery Disease , Percutaneous Coronary Intervention , Humans , Contrast Media , Tomography, Optical Coherence/methods , Artifacts , Iopamidol , Viscosity , Retrospective Studies , Coronary Vessels
SELECTION OF CITATIONS
SEARCH DETAIL