Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 10.508
Filter
1.
PLoS One ; 19(8): e0305480, 2024.
Article in English | MEDLINE | ID: mdl-39088514

ABSTRACT

OBJECTIVE: Most biomechanical research on the application of Kinesio taping (KT) to the ankle joint focused on testing anticipated movements. However, ankle sprains frequently occur in real life in unanticipated situations, where individuals are unprepared and face sudden external stimuli. This situation is completely different from the anticipated situation. The aim of the present study was to investigate the effects of ankle KT application on the kinematic and kinetic characteristics of the knee and ankle joints during unanticipated jump tasks in collegiate athletes. METHODS: Eighteen healthy collegiate athletes experienced three taping conditions in a randomized order: no taping (NT), placebo taping (PT), and KT, and performed unanticipated jump tasks. A 9-camera infrared high-speed motion capture system was employed to collect knee and ankle kinematic data, and a 3-dimensional force plate was utilized to collect knee and ankle kinetic data during the tasks. RESULTS: During the right jumps, KT significantly increased peak knee flexion angle (P = 0.031) compared to NT and significantly decreased peak vertical ground reaction force (P < 0.001, P = 0.001) compared to NT and PT. During the left jumps, KT significantly reduced peak ankle inversion angle (P = 0.022, P < 0.001) and peak ankle inversion moment (P = 0.002, P = 0.001) compared to NT and PT. CONCLUSION: During unanticipated jump maneuvers, KT reduced peak ankle inversion angle, peak vertical ground reaction force, and peak ankle inversion moment and increased peak knee flexion angle in collegiate athletes.


Subject(s)
Ankle Joint , Athletes , Athletic Tape , Knee Joint , Humans , Ankle Joint/physiology , Biomechanical Phenomena , Male , Young Adult , Knee Joint/physiology , Female , Movement/physiology , Range of Motion, Articular/physiology
2.
Clin Orthop Surg ; 16(4): 570-577, 2024 Aug.
Article in English | MEDLINE | ID: mdl-39092300

ABSTRACT

Background: Increased load bearing across the patellofemoral and tibiofemoral articulations has been associated with total knee arthroplasty (TKA) complications. Therefore, the purpose of this study was to quantify the biomechanical characteristics of the patellofemoral and tibiofemoral joints and simulate varying weight-bearing demands after posterior cruciate ligament-retaining (CR) and posterior-stabilized (PS) TKAs. Methods: Eight fresh-frozen cadaveric knees (average age, 68.4 years; range, 40-86 years) were tested using a custom knee system with muscle-loading capabilities. The TKA knees were tested with a CR and then a PS TKA implant and were loaded at 6 different flexion angles from 15° to 90° with progressively increasing loads. The independent variables were the implant types (CR and PS TKA), progressively increased loading, and knee flexion angle (KFA). The dependent variables were the patellofemoral and tibiofemoral kinematics and contact characteristics. Results: The results showed that at higher KFAs, the position of the femur translated significantly more posterior in CR implants than in PS implants (36.6 ± 5.2 mm and 32.5 ± 5.7 mm, respectively). The patellofemoral contact force and contact area were significantly greater in PS than in CR implants at higher KFAs and loads (102.4 ± 12.5 N and 88.1 ± 10.9 N, respectively). Lastly, the tibiofemoral contact force was significantly greater in the CR than the PS implant at flexion angles of 45°, 60°, 75°, and 90° KFA, the average at these flexion angles for all loads tested being 246.1 ± 42.1 N and 192.8 ± 54.8 N for CR and PS implants, respectively. Conclusions: In this biomechanical study, CR TKAs showed less patellofemoral contact force, but more tibiofemoral contact force than PS TKAs. For higher loads across the joint and at increased flexion angles, there was significantly more posterior femur translation in the CR design with a preserved posterior cruciate ligament and therefore significantly less patellofemoral contact area and force than in the PS design. The different effects of loading on implants are an important consideration for physicians as patients with higher load demands should consider the significantly greater patellofemoral contact force and area of the PS over the CR design.


Subject(s)
Arthroplasty, Replacement, Knee , Posterior Cruciate Ligament , Weight-Bearing , Humans , Aged , Biomechanical Phenomena , Aged, 80 and over , Weight-Bearing/physiology , Middle Aged , Posterior Cruciate Ligament/surgery , Adult , Male , Female , Cadaver , Knee Joint/surgery , Knee Joint/physiology , Knee Prosthesis , Patellofemoral Joint/surgery , Patellofemoral Joint/physiology , Range of Motion, Articular
3.
Scand J Med Sci Sports ; 34(8): e14690, 2024 Aug.
Article in English | MEDLINE | ID: mdl-39049546

ABSTRACT

How the neuromechanics of the lower limb functional muscle groups change with running speed remains to be fully elucidated, with implications for our understanding of human locomotion, conditioning, and injury prevention. This study compared the neuromechanics (ground reaction and joint kinetics, kinematics and muscle activity) of middle-distance athletes running on an instrumented treadmill at six wide-ranging speeds (2.78-8.33 m·s-1). Ground reaction forces and kinematics were analyzed using inverse dynamics to calculate flexor and extensor joint torques, and positive and negative work done by these torques. Contributions of each functional muscle group to the total positive and negative work done by the limb during stance, swing, and the whole stride were quantified. During stance, the ankle plantar flexors were the major energy generator and absorber (>60%) at all speeds, but their contribution to whole stride energy generation and absorption declined with speed. Positive work by the hip extensors rose superlinearly with speed during stance (3-fold) and especially during swing (12-fold), becoming the biggest energy generator across the whole stride at >5 m·s-1. Knee flexor and extensor negative work also rose superlinearly with speed during swing, with the knee flexors becoming the greatest energy absorber over the whole stride at >7.22 m·s-1. Across speeds, plantar flexor peak moment and positive work accounted for 97% and 96% of the variance in step length, and swing hip extension peak moment and positive work accounted for 98% and 99% of the variance in step frequency. There were pronounced speed, phase (stance/swing), and work (positive/negative) dependent contributions of the different functional muscle groups during running, with extensive implications for conditioning and injury prevention.


Subject(s)
Muscle, Skeletal , Running , Humans , Running/physiology , Biomechanical Phenomena , Muscle, Skeletal/physiology , Male , Adult , Young Adult , Electromyography , Torque , Lower Extremity/physiology , Ankle Joint/physiology , Female , Gait/physiology , Knee Joint/physiology
4.
Sci Rep ; 14(1): 17022, 2024 Jul 24.
Article in English | MEDLINE | ID: mdl-39043858

ABSTRACT

The meniscal position within the knee is critical to maintain normal knee function. The joint capsule might dynamically coordinate the medial meniscus (MM) by transmitting a semimembranosus action. However, their interrelationships in vivo are unclear. We aimed to determine relationships among the MM, joint capsule, and semimembranosus during passive tibial external-internal and isometric tibial internal rotation at the medial and posteromedial knees of 10 healthy individuals in vivo using ultrasound. We analyzed images of the MM and joint capsule locations at the medial and posteromedial knee and the velocity waveform similarity of each structure during rotational tasks. Both isometric internal rotation with semimembranosus action and passive tibial external rotation displaced the MM inward at the medial knee. The MM and joint capsule during these MM displacements coordinately moved with more than moderate cross-correlation coefficients (passive external and isometric internal rotations, ≥ 0.54 and ≥ 0.90, respectively). The movements of the MM and joint capsule to the semimembranosus during isometric internal rotation also coordinated with moderate cross-correlation coefficients (≥ 0.62). Therefore, the joint capsule might dynamically coordinate the MM by transmitting semimembranosus action. Whether increased tibial internal rotation or semimembranosus shortening causes MM extrusion awaits further investigation.


Subject(s)
Joint Capsule , Menisci, Tibial , Tibia , Humans , Male , Joint Capsule/physiology , Joint Capsule/diagnostic imaging , Adult , Menisci, Tibial/physiology , Menisci, Tibial/diagnostic imaging , Tibia/physiology , Tibia/diagnostic imaging , Rotation , Female , Range of Motion, Articular/physiology , Knee Joint/physiology , Ultrasonography/methods , Young Adult , Biomechanical Phenomena
5.
Sensors (Basel) ; 24(13)2024 Jun 28.
Article in English | MEDLINE | ID: mdl-39000996

ABSTRACT

Accurately estimating knee joint angle during walking from surface electromyography (sEMG) signals can enable more natural control of wearable robotics like exoskeletons. However, challenges exist due to variability across individuals and sessions. This study evaluates an attention-based deep recurrent neural network combining gated recurrent units (GRUs) and an attention mechanism (AM) for knee angle estimation. Three experiments were conducted. First, the GRU-AM model was tested on four healthy adolescents, demonstrating improved estimation compared to GRU alone. A sensitivity analysis revealed that the key contributing muscles were the knee flexor and extensors, highlighting the ability of the AM to focus on the most salient inputs. Second, transfer learning was shown by pretraining the model on an open source dataset before additional training and testing on the four adolescents. Third, the model was progressively adapted over three sessions for one child with cerebral palsy (CP). The GRU-AM model demonstrated robust knee angle estimation across participants with healthy participants (mean RMSE 7 degrees) and participants with CP (RMSE 37 degrees). Further, estimation accuracy improved by 14 degrees on average across successive sessions of walking in the child with CP. These results demonstrate the feasibility of using attention-based deep networks for joint angle estimation in adolescents and clinical populations and support their further development for deployment in wearable robotics.


Subject(s)
Cerebral Palsy , Electromyography , Knee Joint , Neural Networks, Computer , Walking , Humans , Cerebral Palsy/physiopathology , Electromyography/methods , Walking/physiology , Adolescent , Knee Joint/physiopathology , Knee Joint/physiology , Male , Female , Child , Feasibility Studies , Biomechanical Phenomena/physiology , Muscle, Skeletal/physiopathology , Muscle, Skeletal/physiology , Knee/physiopathology , Knee/physiology , Wearable Electronic Devices , Range of Motion, Articular/physiology
6.
Nat Commun ; 15(1): 5756, 2024 Jul 09.
Article in English | MEDLINE | ID: mdl-38982087

ABSTRACT

The human body constantly experiences mechanical loading. However, quantifying internal loads within the musculoskeletal system remains challenging, especially during unconstrained dynamic activities. Conventional measures are constrained to laboratory settings, and existing wearable approaches lack muscle specificity or validation during dynamic movement. Here, we present a strategy for estimating corresponding joint torque from muscles with different architectures during various dynamic activities using wearable A-mode ultrasound. We first introduce a method to track changes in muscle thickness using single-element ultrasonic transducers. We then estimate elbow and knee torque with errors less than 7.6% and coefficients of determination (R2) greater than 0.92 during controlled isokinetic contractions. Finally, we demonstrate wearable joint torque estimation during dynamic real-world tasks, including weightlifting, cycling, and both treadmill and outdoor locomotion. The capability to assess joint torque during unconstrained real-world activities can provide new insights into muscle function and movement biomechanics, with potential applications in injury prevention and rehabilitation.


Subject(s)
Muscle, Skeletal , Torque , Ultrasonography , Wearable Electronic Devices , Humans , Male , Ultrasonography/methods , Ultrasonography/instrumentation , Biomechanical Phenomena , Adult , Muscle, Skeletal/physiology , Muscle, Skeletal/diagnostic imaging , Young Adult , Knee Joint/physiology , Knee Joint/diagnostic imaging , Elbow Joint/physiology , Elbow Joint/diagnostic imaging , Female , Movement/physiology , Joints/physiology , Joints/diagnostic imaging , Muscle Contraction/physiology
7.
BMC Musculoskelet Disord ; 25(1): 527, 2024 Jul 09.
Article in English | MEDLINE | ID: mdl-38982445

ABSTRACT

BACKGROUND: This study investigated the effects of changes in motor skills from an educational video program on the kinematic and kinetic variables of the lower extremity joints and knee ligament load. METHODS: Twenty male participants (age: 22.2 ± 2.60 y; height: 1.70 ± 6.2 m; weight: 65.4 ± 7.01 kg; BMI: 23.32 ± 2.49 [Formula: see text]) were instructed to run at 4.5 ± 0.2 m/s from a 5 m distance posterior to the force plate, land their foot on the force plate, and perform the cutting maneuver on the left. The educational video program for cutting maneuvers consisted of preparatory posture, foot landing orientation, gaze and trunk directions, soft landing, and eversion angle. The measured variables were the angle, angular velocity of lower extremity joints, ground reaction force (GRF), moment, and anterior cruciate ligament (ACL) and medial collateral ligament (MCL) forces through musculoskeletal modeling. RESULTS: After the video feedback, the hip joint angles increased in flexion, abduction, and external rotation (p < 0.05), and the angular velocity increased in extension (p < 0.05). The ankle joint angles increased in dorsiflexion (p < 0.05), and the angular velocity decreased in dorsiflexion (p < 0.05) but increased in abduction (p < 0.05). The GRF increased in the anterior-posterior and medial-lateral directions and decreased vertically (p < 0.05). The hip joint moments decreased in extension and external rotation (p < 0.05) but increased in adduction (p < 0.05). The knee joint moments were decreased in extension, adduction, and external rotation (p < 0.05). The abduction moment of the ankle joint decreased (p < 0.001). There were differences in the support zone corresponding to 64‒87% of the hip frontal moment (p < 0.001) and 32‒100% of the hip horizontal moment (p < 0.001) and differences corresponding to 32‒100% of the knee frontal moment and 21‒100% of the knee horizontal moment (p < 0.001). The GRF varied in the support zone at 44‒95% in the medial-lateral direction and at 17‒43% and 73‒100% in the vertical direction (p < 0.001). CONCLUSIONS: Injury prevention feedback reduced the load on the lower extremity joints during cutting maneuvers, which reduced the knee ligament load, mainly on the MCL.


Subject(s)
Knee Joint , Motor Skills , Weight-Bearing , Humans , Male , Young Adult , Weight-Bearing/physiology , Knee Joint/physiology , Biomechanical Phenomena/physiology , Motor Skills/physiology , Video Recording , Hip Joint/physiology , Ankle Joint/physiology , Adult , Running/physiology , Lower Extremity/physiology
8.
J Biomech Eng ; 146(11)2024 Nov 01.
Article in English | MEDLINE | ID: mdl-38959087

ABSTRACT

Goals of knee replacement surgery are to restore function and maximize implant longevity. To determine how well these goals are satisfied, tibial femoral kinematics and tibial contact kinematics are of interest. Tibiofemoral kinematics, which characterize function, is movement between the tibia and femur whereas tibial contact kinematics, which is relevant to implant wear, is movement of the location of contact by the femoral implant on the tibial articular surface. The purposes of this review article are to describe and critique relevant methods to guide correct implementation. For tibiofemoral kinematics, methods are categorized as those which determine (1) relative planar motions and (2) relative three-dimensional (3D) motions. Planar motions are determined by first finding anterior-posterior (A-P) positions of each femoral condyle relative to the tibia and tracking these positions during flexion. Of the lowest point (LP) and flexion facet center (FFC) methods, which are common, the lowest point method is preferred and the reasoning is explained. 3D motions are determined using the joint coordinate system (JCS) of Grood and Suntay. Previous applications of this JCS have resulted in motions which are largely in error due to "kinematic crosstalk." Requirements for minimizing kinematic crosstalk are outlined followed by an example, which demonstrates the method for identifying a JCS that minimizes kinematic crosstalk. Although kinematic crosstalk can be minimized, the need for a JCS to determine 3D motions is questionable based on anatomical constraints, which limit varus-valgus rotation and compression-distraction translation. Methods for analyzing tibial contact kinematics are summarized and validation of methods discussed.


Subject(s)
Femur , Tibia , Tibia/physiology , Tibia/diagnostic imaging , Biomechanical Phenomena , Humans , Fluoroscopy , Femur/physiology , Femur/diagnostic imaging , Mechanical Phenomena , Knee Joint/physiology , Knee Joint/diagnostic imaging
9.
Physiol Rep ; 12(13): e16034, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38949844

ABSTRACT

This study compared the joint kinematics between the front squat (FS) conducted in the upright (natural gravity) position and in the supine position on a short arm human centrifuge (SAHC). Male participants (N = 12) with no prior experience exercising on a centrifuge completed a FS in the upright position before (PRE) and after (POST) a FS exercise conducted on the SAHC while exposed to artificial gravity (AG). Participants completed, in randomized order, three sets of six repetitions with a load equal to body weight or 1.25 × body weight for upright squats, and 1 g and 1.25 g at the center of gravity (COG) for AG. During the terrestrial squats, the load was applied with a barbell. Knee (left/right) and hip (left/right) flexion angles were recorded with a set of inertial measurement units. AG decreased the maximum flexion angle (MAX) of knees and hips as well as the range of motion (ROM), both at 1 and 1.25 g. Minor adaptation was observed between the first and the last repetition performed in AG. AG affects the ability to FS in naïve participants by reducing MAX, MIN and ROM of the knees and hip.


Subject(s)
Centrifugation , Exercise , Knee Joint , Range of Motion, Articular , Humans , Male , Range of Motion, Articular/physiology , Biomechanical Phenomena , Adult , Knee Joint/physiology , Exercise/physiology , Young Adult , Hip Joint/physiology , Posture/physiology , Gravity, Altered
10.
Sensors (Basel) ; 24(14)2024 Jul 22.
Article in English | MEDLINE | ID: mdl-39066155

ABSTRACT

(1) This study examined the impact of fatigue and unanticipated factors on knee biomechanics during sidestep cutting and lateral shuffling in female basketball players, assessing the potential for non-contact anterior cruciate ligament (ACL) injuries. (2) Twenty-four female basketball players underwent fatigue induction and unanticipated change of direction tests, and kinematic and kinetic parameters were collected before and after fatigue with a Vicon motion capture system and Kistler ground reaction force (GRF) sensor. (3) Analysis using two-way repeated-measures ANOVA showed no significant interaction between fatigue and unanticipated factors on joint kinematics and kinetics. Unanticipated conditions significantly increased the knee joint flexion and extension angle (p < 0.01), decreased the knee flexion moment under anticipated conditions, and increased the knee valgus moment after fatigue (p ≤ 0.05). One-dimensional statistical parametric mapping (SPM1d) results indicated significant differences in GRF during sidestep cutting and knee inversion and rotation moments during lateral shuffling post-fatigue. (4) Unanticipated factors had a greater impact on knee load patterns, raising ACL injury risk. Fatigue and unanticipated factors were independent risk factors and should be considered separately in training programs to prevent lower limb injuries.


Subject(s)
Basketball , Knee Joint , Humans , Basketball/physiology , Female , Biomechanical Phenomena/physiology , Knee Joint/physiology , Young Adult , Anterior Cruciate Ligament Injuries/physiopathology , Adult , Fatigue/physiopathology , Range of Motion, Articular/physiology
11.
J Biomech ; 172: 112178, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38959820

ABSTRACT

Reactive lower limb muscle function during walking plays a key role in balance recovery following tripping, and ultimately fall prevention. The objective of this study was to evaluate muscle and joint function in the recovery limb during balance recovery after trip-based perturbations during walking. Twenty-four healthy participants underwent gait analysis while walking at slow, moderate and fast speeds over level, uphill and downhill inclines. Trip perturbations were performed randomly during stance, and lower limb kinematics, kinetics, and muscle contribution to the acceleration of the whole-body centre of mass (COM) were computed pre- and post-perturbation in the recovery limb. Ground slope and walking speed had a significant effect on lower limb joint angles, net joint moments and muscle contributions to support and propulsion during trip recovery (p < 0.05). Specifically, increasing walking speed during trip recovery significantly reduced hip extension in the recovery limb and increased knee flexion, particularly when walking uphill and at higher walking speeds (p < 0.05). Gluteus maximus played a critical role in providing support and forward propulsion of the body during trip recovery across all gait speeds and ground inclinations. This study provides a mechanistic link between muscle action, joint motion and COM acceleration during trip recovery, and underscores the potential of increased walking speed and ground inclination to increase fall risk, particularly in individuals prone to falling. The findings of this study may provide guidelines for targeted exercise therapy such as muscle strengthening for fall prevention.


Subject(s)
Accidental Falls , Gait , Muscle, Skeletal , Postural Balance , Walking Speed , Humans , Male , Female , Postural Balance/physiology , Muscle, Skeletal/physiology , Walking Speed/physiology , Gait/physiology , Adult , Accidental Falls/prevention & control , Biomechanical Phenomena , Walking/physiology , Knee Joint/physiology , Hip Joint/physiology
12.
Scand J Med Sci Sports ; 34(7): e14693, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38984681

ABSTRACT

BACKGROUND: Two-dimensional (2D) video is a common tool used during sports training and competition to analyze movement. In these videos, biomechanists determine key events, annotate joint centers, and calculate spatial, temporal, and kinematic parameters to provide performance reports to coaches and athletes. Automatic tools relying on computer vision and artificial intelligence methods hold promise to reduce the need for time-consuming manual methods. OBJECTIVE: This study systematically analyzed the steps required to automate the video analysis workflow by investigating the applicability of a threshold-based event detection algorithm developed for 3D marker trajectories to 2D video data at four sampling rates; the agreement of 2D keypoints estimated by an off-the-shelf pose estimation model compared with gold-standard 3D marker trajectories projected to camera's field of view; and the influence of an offset in event detection on contact time and the sagittal knee joint angle at the key critical events of touch down and foot flat. METHODS: Repeated measures limits of agreement were used to compare parameters determined by markerless and marker-based motion capture. RESULTS: Results highlighted that a minimum video sampling rate of 100 Hz is required to detect key events, and the limited applicability of 3D marker trajectory-based event detection algorithms when using 2D video. Although detected keypoints showed good agreement with the gold-standard, misidentification of key events-such as touch down by 20 ms resulted in knee compression angle differences of up to 20°. CONCLUSION: These findings emphasize the need for de novo accurate key event detection algorithms to automate 2D video analysis pipelines.


Subject(s)
Algorithms , Video Recording , Humans , Biomechanical Phenomena , Gait/physiology , Gait Analysis/methods , Knee Joint/physiology , Male , Athletic Performance/physiology , Sports/physiology , Adult
13.
J Appl Biomech ; 40(4): 333-345, 2024 Aug 01.
Article in English | MEDLINE | ID: mdl-39013453

ABSTRACT

The purpose was to examine (1) the effect of measurement position and sex on femoral cartilage outcomes, and (2) the association between gait biomechanics and cartilage outcomes. Fifty individuals participated (25 males and 25 females; age = 20.62 [1.80] y). Ultrasound measured femoral cartilage thickness and echo-intensity at 90°, 115°, and 140° of knee flexion. Gait outcomes included the external knee adduction and knee flexion moments. Cartilage outcomes were compared using 2 (sex) × 3 (position) repeated-measures analysis of variance. Gait and cartilage associations were assessed using stepwise regression. Medial cartilage was thicker when measured at 90° compared with 115° (P = .02) and 140° (P < .01), and 115° compared with 140°, (P < .01) in males but not in females. Cartilage was thicker at 90° compared with 140° across both sexes within all regions (P < .01). Males had thicker cartilage than females in all positions (P < .01). Echo-intensity was lower at 90° than 115° (P < .01) and 140° (P = .01) in the central and lower at 90° than at 115° (P < .01) and 140° (P = .03) in lateral regions. No association was found between gait and cartilage outcomes. Ultrasound imaging position effects cartilage features more in males compared with females. Imaging position and sex influence cartilage outcomes and should be considered in study designs and clinical evaluation.


Subject(s)
Cartilage, Articular , Gait , Ultrasonography , Humans , Male , Female , Cartilage, Articular/diagnostic imaging , Cartilage, Articular/physiology , Young Adult , Gait/physiology , Femur/diagnostic imaging , Femur/physiology , Femur/anatomy & histology , Knee Joint/diagnostic imaging , Knee Joint/physiology , Sex Factors , Biomechanical Phenomena , Range of Motion, Articular/physiology , Adult
14.
J Appl Biomech ; 40(4): 346-355, 2024 Aug 01.
Article in English | MEDLINE | ID: mdl-39013455

ABSTRACT

Following anterior cruciate ligament reconstruction (ACLR), patients exhibit abnormal walking mechanics and quadriceps dysfunction. Quadriceps dysfunction has been largely attributed to muscle atrophy and weakness. While important, these factors do not capture intrinsic properties of muscle that govern its ability to generate force and withstand load. While fascicle abnormalities after ACLR have been documented in early stages of recovery (<12 mo), long-term effects of ACLR on fascicle mechanics remain unexplored. We evaluated quadriceps fascicle mechanics during walking 3 years post-ACLR and examined the relationship with knee mechanics. Participants included 24 individuals with ACLR and 24 Controls. Linear mixed models compared the ACLR, Contralateral, and Controls limbs for (1) quadriceps strength, (2) fascicle architecture and mechanics, and (3) knee mechanics. No difference in strength or overall fascicle length excursions was found between limbs. The ACLR limb exhibited longer fascicles at heel strike and peak knee extension moment (P < .001-.004), and smaller fascicle angles at heel strike, peak knee extension moment, and overall suppressed fascicle angle excursions (P < .001-.049) relative to the Contralateral and/or Control limb. This indicates an abnormality in fascicle architecture and mechanics following ACLR and suggests abnormalities in contractile function that cannot be explained by muscle weakness and may contribute to long-term gait irregularities.


Subject(s)
Anterior Cruciate Ligament Reconstruction , Quadriceps Muscle , Humans , Male , Female , Biomechanical Phenomena , Adult , Quadriceps Muscle/physiopathology , Quadriceps Muscle/physiology , Adaptation, Physiological , Knee Joint/physiopathology , Knee Joint/physiology , Muscle Strength/physiology , Walking/physiology , Young Adult
15.
J Int Med Res ; 52(7): 3000605241262186, 2024 Jul.
Article in English | MEDLINE | ID: mdl-39053453

ABSTRACT

OBJECTIVE: Existing isokinetic contractions are characterized using standardized angular velocities, which can induce differing adaptations. Here, we characterized the variation in the isokinetic parameters of knee extensors according to individualized angular velocity (IAV). METHODS: We performed a cross-sectional study of 19 young, healthy men. We measured the maximum angular velocity (MAV) of concentric knee extension using the isotonic mode of an isokinetic dynamometer. Isometric and isokinetic (at angular velocities corresponding to 100%, 70%, 40%, and 10% of each individual's MAV) knee extensor contractions were performed, and the peak torque and mean power were recorded. RESULTS: Peak torque significantly decreased with increasing IAV (129.42 ± 25.04, 84.37 ± 20.97, and 56.42 ± 16.18 Nm at 40%, 70%, and 100%, respectively), except for isometric contraction (233.36 ± 47.85) and at 10% of MAV (208 ± 48.55). At the mean power, 10% of MAV (74.52 ± 20.84 W) was significantly lower than the faster IAV (176.32 ± 49.64, 161.53 ± 56.55, and 145.95 ± 50.64 W at 40%, 70%, and 100%, respectively), and 100% was significantly lower than 40%. CONCLUSION: The optimized IAV for isokinetic contraction to improve power output while maintaining torque is 10% to 40% of MAV. IAV may reflect both the velocity and force components of power because individuals do not have the same angular velocity.


Subject(s)
Isometric Contraction , Knee , Muscle, Skeletal , Torque , Humans , Male , Young Adult , Isometric Contraction/physiology , Adult , Cross-Sectional Studies , Muscle, Skeletal/physiology , Knee/physiology , Muscle Strength/physiology , Knee Joint/physiology , Biomechanical Phenomena/physiology , Muscle Contraction/physiology
16.
Mol Biol Rep ; 51(1): 862, 2024 Jul 29.
Article in English | MEDLINE | ID: mdl-39073659

ABSTRACT

BACKGROUND: Understanding how healthy articular cartilage responds to mechanical loading is critical. Moderate mechanical loading has positive effects on the cartilage, such as maintaining cartilage homeostasis. The degree of mechanical loading is determined by a combination of intensity, frequency, and duration; however, the best combination of these parameters for knee cartilage remains unclear. This study aimed to determine which combination of intensity, frequency, and duration provides the best mechanical loading on healthy knee articular cartilage in vitro and in vivo. METHODS AND RESULTS: In this study, 33 male mice were used. Chondrocytes isolated from mouse knee joints were subjected to different cyclic tensile strains (CTSs) and assessed by measuring the expression of cartilage matrix-related genes. Furthermore, the histological characteristics of mouse tibial cartilages were quantified using different treadmill exercises. Chondrocytes and mice were divided into the control group and eight intervention groups: high-intensity, high-frequency, and long-duration; high-intensity, high-frequency, and short-duration; high-intensity, low-frequency, and long-duration; high-intensity, low-frequency, and short-duration; low-intensity, high-frequency, and long-duration; low-intensity, high-frequency, and short-duration; low-intensity, low-frequency, and long-duration; low-intensity, low-frequency, and short-duration. In low-intensity CTSs, chondrocytes showed anabolic responses by altering the mRNA expression of COL2A1 in short durations and SOX9 in long durations. Furthermore, low-intensity, low-frequency, and long-duration treadmill exercises minimized chondrocyte hypertrophy and enhanced aggrecan synthesis in tibial cartilages. CONCLUSION: Low-intensity, low-frequency, and long-duration mechanical loading is the best combination for healthy knee cartilage to maintain homeostasis and activate anabolic responses. Our findings provide a significant scientific basis for exercise and lifestyle instructions.


Subject(s)
Cartilage, Articular , Chondrocytes , Stress, Mechanical , Weight-Bearing , Animals , Cartilage, Articular/metabolism , Cartilage, Articular/physiology , Mice , Chondrocytes/metabolism , Male , Weight-Bearing/physiology , Physical Conditioning, Animal/physiology , SOX9 Transcription Factor/metabolism , SOX9 Transcription Factor/genetics , Collagen Type II/metabolism , Collagen Type II/genetics , Knee Joint/metabolism , Knee Joint/physiology , Mice, Inbred C57BL
17.
Eur J Sport Sci ; 24(8): 1095-1109, 2024 Aug.
Article in English | MEDLINE | ID: mdl-39022860

ABSTRACT

This study investigated the effects of plyometric training on lower-limb muscle strength and knee biomechanical characteristics during the landing phase. Twenty-four male subjects were recruited for this study with a randomised controlled design. They were randomly divided into a plyometric training group and a traditional training group and underwent training for 16 weeks. Each subject was evaluated every 8 weeks for knee and hip isokinetic muscle strength as well as knee kinematics and kinetics during landing. The results indicated significant group and time interaction effects for knee extension strength (F = 74.942 and p = 0.001), hip extension strength (F = 99.763 and p = 0.000) and hip flexion strength (F = 182.922 and p = 0.000). For landing kinematics, there were significant group main effects for knee flexion angle range (F = 4.429 and p = 0.047), significant time main effects for valgus angle (F = 6.502 and p = 0.011) and significant group and time interaction effects for internal rotation angle range (F = 5.475 and p = 0.008). The group main effect for maximum knee flexion angle was significant (F = 7.534 and p = 0.012), and the group and time interaction effect for maximum internal rotation angle was significant (F = 15.737 and p = 0.001). For landing kinetics, the group main effect of the loading rate was significant (F = 4.576 and p = 0.044). Significant group and time interaction effects were observed for knee extension moment at the moment of maximum vertical ground reaction force (F = 5.095 and p = 0.010) and for abduction moment (F = 8.250 and p = 0.001). These findings suggest that plyometric training leads to greater improvements in hip and knee muscle strength and beneficial changes in knee biomechanics during landing compared to traditional training.


Subject(s)
Knee Joint , Muscle Strength , Plyometric Exercise , Humans , Male , Biomechanical Phenomena , Young Adult , Muscle Strength/physiology , Knee Joint/physiology , Knee/physiology , Athletes , Adult , Range of Motion, Articular/physiology , Hip/physiology
18.
Sensors (Basel) ; 24(11)2024 May 22.
Article in English | MEDLINE | ID: mdl-38894101

ABSTRACT

Lower limb exoskeletons have the potential to mitigate work-related musculoskeletal disorders; however, they often lack user-oriented control strategies. Human-in-the-loop (HITL) controls adapt an exoskeleton's assistance in real time, to optimize the user-exoskeleton interaction. This study presents a HITL control for a knee exoskeleton using a CMA-ES algorithm to minimize the users' physical effort, a parameter innovatively evaluated using the interaction torque with the exoskeleton (a muscular effort indicator) and metabolic cost. This work innovates by estimating the user's metabolic cost within the HITL control through a machine-learning model. The regression model estimated the metabolic cost, in real time, with a root mean squared error of 0.66 W/kg and mean absolute percentage error of 26% (n = 5), making faster (10 s) and less noisy estimations than a respirometer (K5, Cosmed). The HITL reduced the user's metabolic cost by 7.3% and 5.9% compared to the zero-torque and no-device conditions, respectively, and reduced the interaction torque by 32.3% compared to a zero-torque control (n = 1). The developed HITL control surpassed a non-exoskeleton and zero-torque condition regarding the user's physical effort, even for a task such as slow walking. Furthermore, the user-specific control had a lower metabolic cost than the non-user-specific assistance. This proof-of-concept demonstrated the potential of HITL controls in assisted walking.


Subject(s)
Algorithms , Exoskeleton Device , Torque , Humans , Knee/physiology , Machine Learning , Male , Muscle, Skeletal/physiology , Adult , Biomechanical Phenomena/physiology , Energy Metabolism/physiology , Walking/physiology , Knee Joint/physiology
19.
Sensors (Basel) ; 24(11)2024 May 23.
Article in English | MEDLINE | ID: mdl-38894115

ABSTRACT

Recently, inertial measurement units have been gaining popularity as a potential alternative to optical motion capture systems in the analysis of joint kinematics. In a previous study, the accuracy of knee joint angles calculated from inertial data and an extended Kalman filter and smoother algorithm was tested using ground truth data originating from a joint simulator guided by fluoroscopy-based signals. Although high levels of accuracy were achieved, the experimental setup leveraged multiple iterations of the same movement pattern and an absence of soft tissue artefacts. Here, the algorithm is tested against an optical marker-based system in a more challenging setting, with single iterations of a loaded squat cycle simulated on seven cadaveric specimens on a force-controlled knee rig. Prior to the optimisation of local coordinate systems using the REference FRame Alignment MEthod (REFRAME) to account for the effect of differences in local reference frame orientation, root-mean-square errors between the kinematic signals of the inertial and optical systems were as high as 3.8° ± 3.5° for flexion/extension, 20.4° ± 10.0° for abduction/adduction and 8.6° ± 5.7° for external/internal rotation. After REFRAME implementation, however, average root-mean-square errors decreased to 0.9° ± 0.4° and to 1.5° ± 0.7° for abduction/adduction and for external/internal rotation, respectively, with a slight increase to 4.2° ± 3.6° for flexion/extension. While these results demonstrate promising potential in the approach's ability to estimate knee joint angles during a single loaded squat cycle, they highlight the limiting effects that a reduced number of iterations and the lack of a reliable consistent reference pose inflicts on the sensor fusion algorithm's performance. They similarly stress the importance of adapting underlying assumptions and correctly tuning filter parameters to ensure satisfactory performance. More importantly, our findings emphasise the notable impact that properly aligning reference-frame orientations before comparing joint kinematics can have on results and the conclusions derived from them.


Subject(s)
Algorithms , Knee Joint , Range of Motion, Articular , Humans , Biomechanical Phenomena/physiology , Knee Joint/physiology , Range of Motion, Articular/physiology , Cadaver , Movement/physiology , Male , Knee/physiology
20.
Sensors (Basel) ; 24(11)2024 Jun 05.
Article in English | MEDLINE | ID: mdl-38894442

ABSTRACT

Laboratory studies have limitations in screening for anterior cruciate ligament (ACL) injury risk due to their lack of ecological validity. Machine learning (ML) methods coupled with wearable sensors are state-of-art approaches for joint load estimation outside the laboratory in athletic tasks. The aim of this study was to investigate ML approaches in predicting knee joint loading during sport-specific agility tasks. We explored the possibility of predicting high and low knee abduction moments (KAMs) from kinematic data collected in a laboratory setting through wearable sensors and of predicting the actual KAM from kinematics. Xsens MVN Analyze and Vicon motion analysis, together with Bertec force plates, were used. Talented female football (soccer) players (n = 32, age 14.8 ± 1.0 y, height 167.9 ± 5.1 cm, mass 57.5 ± 8.0 kg) performed unanticipated sidestep cutting movements (number of trials analyzed = 1105). According to the findings of this technical note, classification models that aim to identify the players exhibiting high or low KAM are preferable to the ones that aim to predict the actual peak KAM magnitude. The possibility of classifying high versus low KAMs during agility with good approximation (AUC 0.81-0.85) represents a step towards testing in an ecologically valid environment.


Subject(s)
Machine Learning , Soccer , Humans , Female , Biomechanical Phenomena/physiology , Soccer/physiology , Adolescent , Knee Joint/physiology , Anterior Cruciate Ligament Injuries/physiopathology , Movement/physiology , Weight-Bearing/physiology , Wearable Electronic Devices
SELECTION OF CITATIONS
SEARCH DETAIL