Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 1.584
Filter
1.
J Pharm Biomed Anal ; 248: 116319, 2024 Sep 15.
Article in English | MEDLINE | ID: mdl-38908235

ABSTRACT

Polycyclic aromatic hydrocarbons (PAHs) are persistent organic pollutants of great concern due to their carcinogenicity and mutagenicity. Their determination in human serum, particularly in at-risk populations, is necessary but difficult because they are distributed over a wide range of polarity and are present at trace level. A new method combining salting-out assisted liquid-liquid extraction (SALLE) and dispersive liquid-liquid microextraction with solidification of floating organic drop (DLLME-SFO) adapted to a reduced volume of sample (100 µl) was developed to determine 24 PAHs in human serum. Some key parameters of DLLME-SFO (volume of extraction solvent, ratio of extraction/dispersive solvent volumes, and salt addition) were first studied by applying it to spiked pure water. For its application to serum, a sample treatment step involving SALLE was optimized in terms of nature and content of salts and applied upstream of DLLME-SFO. It was applied to the extraction of 24 regulated PAHs from spiked serum followed by an analysis by liquid chromatography coupled with UV and fluorescence detection. The extraction recoveries ranged from 48.2 and 116.0 % (relative standard deviations: 2.0-14.6 %, n=5-9), leading to limits of quantification of PAHs in human serum from 0.04 to 1.03 µg/L using fluorescence detection and from 10 to 40 µg/L using UV detection. This final method combining SALLE and DLLME-SFO showed numerous advantages such as no evaporation step, high efficiency and low solvent-consumption and will be useful for monitoring PAHs in low volumes of serum.


Subject(s)
Liquid Phase Microextraction , Liquid-Liquid Extraction , Polycyclic Aromatic Hydrocarbons , Solvents , Humans , Liquid Phase Microextraction/methods , Polycyclic Aromatic Hydrocarbons/blood , Polycyclic Aromatic Hydrocarbons/analysis , Solvents/chemistry , Liquid-Liquid Extraction/methods , Limit of Detection , Salts/chemistry , Chromatography, High Pressure Liquid/methods , Chromatography, Liquid/methods
2.
Anal Chim Acta ; 1313: 342790, 2024 Jul 18.
Article in English | MEDLINE | ID: mdl-38862205

ABSTRACT

BACKGROUND: Extensive use of antibiotics leads to widespread environmental pollution, endangering ecosystems, and human health. It is particularly concerning, posing global threats requiring urgent attention and action. In this regard, the shift to mass spectrometry in determining antibiotics is highly desirable. Significant progress has been made in analyzing and optimizing the sensitivity of high-salt samples. However, the persistence of cumbersome operational procedures presents a significant challenge to this shift. Thus, the persistence of complex operational procedures needs to be addressed. RESULTS: In this study, a rapid and direct method for determining antibiotics in highly saline environmental water samples using microsyringe-based slug-flow microextraction (MSFME)-droplet spray ionization (DSI) mass spectrometry (MS) has been described. The proposed method successfully detected clarithromycin, ofloxacin, and sulfadimidine in seawater within a linear range of 1-1200 ng mL-1, with low limits of detection of 0.19 ng mL-1, 0.17 ng mL-1, and 0.20 ng mL-1, respectively (Signal/Noise = 3). Additionally, spiked real seawater samples of all three antibiotics demonstrated satisfactory recoveries (95.1-107.5%) and precision (RSD≤8.8%). The MSFME-treated high-salt sample (3.5 wt%) showed a mass spectral response intensity 4-5 orders of magnitude higher than the untreated medium-salt sample (0.35 wt%). Furthermore, exploration of the applicability of MSFME showed that it is suitable not only for high-salinity (3.5 wt%) samples but also for salt-free or low-salt and hard water samples rich in calcium and magnesium ions. SIGNIFICANCE: Comparisons with other methods, complex laboratory setups for sample processing are now simplified to a single step, completing the entire process, including desalination and detection, MSFME-DSI-MS provides faster results in less than 1 min while maintaining sensitivity comparable to that of other detection methods. In conclusion, this advancement provides an exceptionally simplified protocol for the rapid, highly sensitive, and quantitative determination of antibiotics in environmental water samples.


Subject(s)
Anti-Bacterial Agents , Seawater , Water Pollutants, Chemical , Anti-Bacterial Agents/analysis , Seawater/chemistry , Seawater/analysis , Water Pollutants, Chemical/analysis , Liquid Phase Microextraction/methods , Limit of Detection
3.
Molecules ; 29(11)2024 May 24.
Article in English | MEDLINE | ID: mdl-38893365

ABSTRACT

The use of z-drugs has increased worldwide since its introduction. Although the prescribing patterns of hypnotics differ among countries, zolpidem is the most widely used z-drug in the world. Zolpidem may be involved in poisoning and deaths. A simple and fast HPLC-PDA method was developed and validated. Zolpidem and the internal standard chloramphenicol were extracted from plasma using a sonication-assisted dispersive liquid-liquid microextraction procedure. The method was validated including selectivity, linearity, precision, accuracy, and recovery. The calibration range (0.15-0.6 µg/mL) covers therapeutic and toxic levels of zolpidem in plasma. The limit of quantification was set at 0.15 µg/mL. Intra- and interday accuracy and precision values were lower than 15% at the concentration levels studied. Excellent recovery results were obtained for all concentrations. The proposed method was successfully applied to ten real postmortem plasma samples. In our series, multiple substances (alcohol and/or other drugs) were detected in most cases of death involving zolpidem. Our analytical method is suitable for routine toxicological analysis.


Subject(s)
Liquid Phase Microextraction , Zolpidem , Zolpidem/blood , Humans , Liquid Phase Microextraction/methods , Chromatography, High Pressure Liquid/methods , Sonication/methods , Reproducibility of Results , Hypnotics and Sedatives/blood , Limit of Detection , Pyridines/blood
4.
Anal Methods ; 16(24): 3983-3992, 2024 Jun 20.
Article in English | MEDLINE | ID: mdl-38853673

ABSTRACT

Edible oil-based switchable-hydrophilicity solvent liquid-liquid microextraction was coupled with smartphone digital image colorimetry for the determination of total curcuminoids. Images of the colored extracts were captured in a laboratory-made colorimetric box, which were then split into their red-green-blue channels. Optimum extraction conditions were achieved using 550 µL of almond oil as the extraction solvent and 0.40 M sodium hydroxide for hydrolysis of the oil to the salt of its fatty acid. Phosphoric acid (2.0 mL, 4.0 M) was used as the hydrophilicity-switching trigger, while pH of the sample solution adjusted to 5.50 and extraction time of 1.0 min, were found to be optimum. Optimum detection conditions were achieved at a distance of 7.0 cm from the detection camera, a region of interest of 175 px2, a detection wavelength of 420 nm and 50.0% brightness of the light source. The limit of detection was found to be 0.020 µg mL-1. A good linearity was achieved as indicated by coefficients of determination above 0.9965. The proposed method was used for the determination of total curcuminoids in tea and turmeric samples with percentage relative recoveries of 95.0-105.0% and percentage relative standard deviations below 8.7%.


Subject(s)
Colorimetry , Liquid Phase Microextraction , Plant Oils , Smartphone , Liquid Phase Microextraction/methods , Colorimetry/methods , Plant Oils/chemistry , Hydrophobic and Hydrophilic Interactions , Curcumin/analysis , Curcumin/chemistry , Food Analysis/methods , Solvents/chemistry , Limit of Detection
5.
Food Chem ; 454: 139785, 2024 Oct 01.
Article in English | MEDLINE | ID: mdl-38823199

ABSTRACT

In this study, a cheap, fast and simple orbital shaker-assisted fatty acid-based switchable solvent microextraction (OS-FASS-ME) procedure was developed for the extraction of amoxicillin (AMOX) in dairy products, pharmaceutical samples and wastewater prior to its spectrophotometric analysis. Fatty acid-based switchable solvents were investigated for extracting AMOX. The key factors of the OS-FASS-ME procedure were optimized using a central composite design. The linearity of OS-FASS-ME procedure was in the range 5-600 ng mL-1 with a correlation coefficient of 0.991. In five replicate experiments for 20 ng mL-1 of AMOX solution, the recovery and relative standard deviation were 95.8% and 2.2%, respectively. Limits of detection and quantification were found 1.5 ng mL-1 and 5 ng mL-1, respectively. The accuracy, precision, robustness and selectivity of the OS-FASS-ME procedure were investigated in detail under optimum conditions. The OS-FASS-ME procedure was applied to milk, cheese, wastewater, syrups and tablets. A comparison of the results obtained from the reference method and the OS-FASS-ME method showed that the OS-FASS-ME procedure can be successfully applied to complex matrices.


Subject(s)
Amoxicillin , Fatty Acids , Liquid Phase Microextraction , Amoxicillin/chemistry , Amoxicillin/isolation & purification , Amoxicillin/analysis , Liquid Phase Microextraction/methods , Fatty Acids/chemistry , Wastewater/chemistry , Wastewater/analysis , Anti-Bacterial Agents/chemistry , Anti-Bacterial Agents/analysis , Anti-Bacterial Agents/isolation & purification , Solvents/chemistry , Green Chemistry Technology , Animals , Milk/chemistry , Dairy Products/analysis
6.
Anal Bioanal Chem ; 416(18): 4057-4070, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38842689

ABSTRACT

A novel ferrofluid prepared from a hydrophobic deep eutectic solvent (DES) and Fe3O4@graphite composite materials was introduced as a green microextraction medium for the separation and enrichment of trace estrogens in real samples. It was found that the ferrofluid greatly improved the capacity and selectivity of target analytes, benefiting from the enrichment of both DES and Fe3O4@graphite composite materials. Using a combination of high-performance liquid chromatography-fluorescence detection (HPLC-FLD) and vortex-assisted liquid-liquid microextraction (VALLME), a new method was established for simultaneous rapid processing and accurate determination of three estrogens (estradiol [E2], estriol [E3], and ethinyl estradiol [EE2]) in environmental water and urine samples. Key parameters affecting the extraction efficiency were optimized using a single-factor approach and response surface methodology. Under optimal conditions, this method yielded a low limit of detection (1.01 ng L-1, 3.03 ng L-1, and 25.0 ng L-1 for EE2, E2, and E3, respectively), wide linear range (3-200,000 ng L-1), high enrichment factors (9.81-47.2), and satisfactory recovery (73.8-129.0%). Compared with traditional analytical techniques, this method avoids the use of volatile toxic organic extraction solvents and cumbersome phase separation operations.


Subject(s)
Estrogens , Hydrophobic and Hydrophilic Interactions , Limit of Detection , Liquid Phase Microextraction , Water Pollutants, Chemical , Estrogens/urine , Estrogens/analysis , Water Pollutants, Chemical/urine , Water Pollutants, Chemical/analysis , Liquid Phase Microextraction/methods , Chromatography, High Pressure Liquid/methods , Deep Eutectic Solvents/chemistry , Humans
7.
Chemosphere ; 359: 142311, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38735500

ABSTRACT

Plastic is widely used in agricultural applications, but its waste has an adverse environmental impact and a long-term detrimental effect. The development of biodegradable plastics for agricultural use is increasing to mitigate plastic waste. The most commonly used biodegradable plastic is poly(butylene adipate co-terephthalate)/poly(lactic acid) (PBAT/PLA) polymer. In this study, an analytical procedure based on dispersive liquid-liquid microextraction (DLLME) followed by gas chromatography-mass spectrometry (GC-MS) in combination with chemometrics has been optimized to assess the degradation level of PBAT/PLA films by monitoring their characteristic degradation products. Carboxylic acids (benzoic, phthalic, adipic, heptanoic, and octadecanoic acids) and 1,4-butanediol have been found to be potential markers of PBAT/PLA degradation. The DLLME-GC-MS analytical approach has been applied for the first time to assess the degradation efficiency of several microorganisms used as degradation accelerators of PBAT/PLA based on the assigned potential markers. This analytical strategy has shown higher sensitivity and precision than standard techniques, such as elemental analysis, allowing us to detect low degradation levels.


Subject(s)
Biodegradation, Environmental , Gas Chromatography-Mass Spectrometry , Polyesters , Polyesters/chemistry , Liquid Phase Microextraction/methods , Biodegradable Plastics/chemistry , Polymers/chemistry , Carboxylic Acids/chemistry
8.
Anal Bioanal Chem ; 416(15): 3533-3542, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38691170

ABSTRACT

The utilization of supramolecular deep eutectic solvent eddy-assisted liquid-liquid microextraction utilizing 2-hydroxypropyl ß-cyclodextrin (SUPRADES) has been identified as a successful method for pre-enriching Cu, Zn, and Mn in vegetable oil samples. Determination of each element was conducted by inductively coupled plasma optical emission spectrometry (ICP-OES) after digestion of metal-enriched phases. Various parameters were examined, including the composition of SUPRADES species [2HP-ß-CD: DL-lactic acid], a cyclodextrin mass ratio of 20 wt%, a water bath temperature of 75 °C, an extractor volume of 800 µL, a dispersant volume of 50 µL, and an eddy current time of 5 min. Optimal conditions resulted in extraction rates of 99.6% for Cu, 105.2% for Zn, and 101.5% for Mn. The method exhibits a broad linear range spanning from 10 to 20,000 µg L-1, with determination coefficients exceeding 0.99 for all analytes. Enrichment coefficients of 24, 21, and 35 were observed. Limits of detection ranged from 0.89 to 1.30 µg L-1, while limits of quantification ranged from 3.23 to 4.29 µg L-1. The unique structural characteristics of the method enable the successful determination of trace elements in a variety of edible vegetable oils.


Subject(s)
Plant Oils , Solvents , Trace Elements , Plant Oils/chemistry , Trace Elements/analysis , Solvents/chemistry , Liquid Phase Microextraction/methods , Limit of Detection , 2-Hydroxypropyl-beta-cyclodextrin/chemistry , Food Contamination/analysis , Metals/chemistry , Metals/analysis
9.
J Pharm Biomed Anal ; 246: 116236, 2024 Aug 15.
Article in English | MEDLINE | ID: mdl-38772203

ABSTRACT

As the adulteration of dietary supplements with synthetic drugs remains a prevalent issue, the inclusion of anti-obesity agents may pose health risks, potentially leading to central nervous system or cardiovascular diseases. However, surveillance studies on the use of anti-obesity agents by the Chinese population are limited. This study aims to establish an efficient and rapid hair pretreatment method using dispersive liquid-liquid microextraction (DLLME) combined with high-speed grinding and develop a sensitive and accurate analytical method employing ultra high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) for detecting 13 potential anti-obesity agents in hair samples. Herein, hair samples were washed sequentially with 0.1% sodium dodecyl sulfate (SDS), water and acetone, and then ground at high speed using 1 mL of an extraction solution (internal standard solution-n-butanol-1.2 mol/L Na2HPO4, pH10.0, 100:400:500, v/v/v for procaterol; internal standard solution-ethyl acetate-1.2 mol/L Na2HPO4, pH8.0, 100:300:600, v/v/v for other 12 anti-obesity agents) while simultaneously performing DLLME. The developed method successfully detected 13 anti-obesity agents within 11 min, including bambuterol, clenbuterol, ractopamine, clorprenaline, formoterol, salbutamol, terbutaline, procaterol, phentermine, bupropion, sibutramine, desmethyl sibutramine, and N,N-didesmethyl sibutramine, which improved the screening efficiency. The calibration curves exhibited good linearity of 0.025-5 ng/mg, achieving correlation coefficients of r ≥ 0.99. The lower limits of quantification (LLOQs) for the analytes were 0.025 ng/mg, demonstrating acceptable levels of accuracy and precision. Recovery rates ranged between 73.30% and 107.47% across the three concentrations of 0.075, 0.375, and 3.75 ng/mg. The validated method was successfully applied to 369 real cases and detected six analytes, including bambuterol, salbutamol, terbutaline, sibutramine, desmethyl sibutramine, and N,N-didesmethyl sibutramine. This method offers several advantages, including simple pretreatment, high extraction efficiency, rapid extraction, solvent economy, and pollution mitigation, making it highly suitable for large-scale surveillance of usage of added anti-obesity agents.


Subject(s)
Anti-Obesity Agents , Hair , Liquid Phase Microextraction , Tandem Mass Spectrometry , Tandem Mass Spectrometry/methods , Anti-Obesity Agents/analysis , Liquid Phase Microextraction/methods , Chromatography, High Pressure Liquid/methods , Hair/chemistry , Humans , Limit of Detection , Reproducibility of Results
10.
Talanta ; 277: 126236, 2024 Sep 01.
Article in English | MEDLINE | ID: mdl-38795590

ABSTRACT

The dyeing and adulteration of traditional Chinese medicines (TCMs) are continuously updated. Valuable analytical methods for the daily inspection of illegal colorant additives in TCMs and the preparations are in demand. Two deep eutectic solvent (DES)-based vortex-assisted liquid-liquid microextraction (VA-LLME) and ultrasonic-assisted solid-liquid microextraction (UA-SLME) were developed for the sample pretreatment of ten water-soluble colorants and five water-insoluble colorants, respectively, followed by an HPLC-DAD detection. Fifteen colorants were analyzed at four detection wavelengths within 40 min of gradient elution. The optimal DES of VA-LLME and UA-SLME were screened from 23 homemade DESs. The factors affecting the extraction efficiency of VA-LLME and UA-SLME were optimized systematically. Under the optimal conditions, ten water-soluble colorants analyzed by DES-based VA-LLME-HPLC-DAD showed good linearity (R ≥ 0.9995) within the optimal linear range. The LODs and LOQs were 0.2-1.0 µg g-1 and 0. 5-5.0 µg g-1, respectively. The recoveries of spiked samples were 80.2%-104.7 %, with RSDs ≤ 4.39 %. Five water-insoluble colorants of Sudan I‒IV and Sudan 7B analyzed by DES-based UA-SLME-HPLC-DAD showed good linearity (R ≥ 0.9995) within the optimal linear range. The LODs and LOQs were 0.8-8.0 µg g-1 and 4.0-40.0 µg g-1, respectively. The recoveries of spiked samples were 94.2%-103.1 %, with RSDs ≤ 4.81 %. The proposed DES-based VA-LLME-HPLC-DAD was successfully applied to analyze six water-soluble yellow colorants in Cuscutae Semen, salted Cuscutae Semen, and four water-soluble red colorants in Schisandrae Chinensis Fructus. The proposed DES-based UA-SLME-HPLC-DAD was successfully applied to analyze five water-insoluble red colorants in Dieda pills. The study provides analytical method options for routine tests of water-soluble, water-insoluble, or both water-soluble/-insoluble illegal colorant additives in herbal medical materials and preparations by the relevant proposed DES-based sample pretreatment method or a combination of the two proposed DES-based methods.


Subject(s)
Coloring Agents , Drugs, Chinese Herbal , Hydrophobic and Hydrophilic Interactions , Liquid Phase Microextraction , Chromatography, High Pressure Liquid/methods , Liquid Phase Microextraction/methods , Coloring Agents/chemistry , Coloring Agents/analysis , Drugs, Chinese Herbal/chemistry , Drugs, Chinese Herbal/analysis , Medicine, Chinese Traditional , Solvents/chemistry
11.
Food Chem ; 451: 139538, 2024 Sep 01.
Article in English | MEDLINE | ID: mdl-38704991

ABSTRACT

In this paper, a green, cost-effective sample preparation method based on air assisted liquid phase microextraction (AA-LPME) was developed for the simultaneous extraction of As(III) and Sb(III) ions from vegetable samples using hydrophilic/hydrophobic natural deep eutectic solvents (NADESs). Central composite design was used for the optimization of extraction factors including NADES volume, extraction cycle, pH, and curcumin concentration. Limits of detection for As(III) and Sb(III) were 1.5 ng L-1 and 0.06 ng L-1, respectively. Working ranges for As(III) and Sb(III) were 0.2-300 ng L-1 (coefficient of determination (R2 = 0.9978) and 5-400 ng L-1 (R2 = 0.9996), respectively. Relative standard deviations for As(III) and Sb(III) were 2.2-2.8% and 2.9-3.2%, respectively. Enrichment factor of the method was 184 for As(III) and 172 for Sb(III). The accuracy and precision of the AA-NADES-LPME method were investigated by intraday/interday studies and standard reference material analysis, respectively. Finally, the AA-NADES-LPME method was successfully applied to microwave digested vegetable samples using the standard addition approach and acceptable recoveries were achieved.


Subject(s)
Hydrophobic and Hydrophilic Interactions , Liquid Phase Microextraction , Vegetables , Vegetables/chemistry , Liquid Phase Microextraction/methods , Food Contamination/analysis , Deep Eutectic Solvents/chemistry
12.
Anal Chim Acta ; 1307: 342620, 2024 Jun 08.
Article in English | MEDLINE | ID: mdl-38719413

ABSTRACT

BACKGROUND: Pharmacokinetic studies are pivotal in drug development, focusing on absorption, distribution, and excretion of active compounds. Effective sample preparation methods play a crucial role in these studies. Traditional techniques like protein precipitation and liquid-liquid extraction often involve toxic solvents and are time-consuming. Recently, deep eutectic solvent (DES) has emerged as an eco-friendly alternative due to its high efficiency, low cost, and low toxicity. This study introduces a novel sample pretreatment method using CO2-switchable DES in liquid-liquid microextraction (LLME) to enhance speed, accuracy, and sensitivity in complex biological samples analysis. RESULTS: A liquid-liquid microextraction sample pretreatment method based on switchable DES combined with high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) was established for the analysis of urine and tissue samples. The method was optimized through systematic investigation of key parameters, including DES type, volume, molar ratio, pH, vortex time, gas purge time, and salt addition. The resulting procedure exhibited satisfying linearity (r2 ≥ 0.9958), good precision (RSD ≤6.01 %), desirable recovery (52.44%-98.12 %) and matrix effect (86.22%-119.30 %), and the accuracy and precision of stability were within the ±15 % limit. The proven methods were further applied to urinary excretion study and tissue distribution study of Nelumbinis plumula (NP) extract. The results indicated that the total cumulative excretion of liensinine, isoliensinine and neferine in urine within 240 h was 4.96 %, 0.66 % and 0.44 %, respectively. The tissue distribution study showed that alkaloids mainly distribute in liver, kidney, and spleen. SIGNIFICANCE: This research introduces a groundbreaking technique distinguished by its simplicity, speed, cost-effectiveness, and environmental friendliness. This approach, utilizing CO2-switchable DES as an extraction solvent for LLME, integrates deproteinization and removal of interfering molecules into a single step. This integration showcases its efficiency and convenience, demonstrating significant promise for various applications in the analysis of biological samples. Additionally, this study provides the first report on urinary excretion and tissue distribution of alkaloids from NP using a DES-LLME method. These findings offer valuable insights into the in vivo behavior of herbal medicine, enhancing understanding of pharmacological actions and facilitating clinical rational administration.


Subject(s)
Carbon Dioxide , Deep Eutectic Solvents , Liquid Phase Microextraction , Tandem Mass Spectrometry , Liquid Phase Microextraction/methods , Carbon Dioxide/chemistry , Deep Eutectic Solvents/chemistry , Animals , Tissue Distribution , Tandem Mass Spectrometry/methods , Chromatography, High Pressure Liquid , Male , Rats , Rats, Sprague-Dawley
13.
Food Chem ; 453: 139660, 2024 Sep 30.
Article in English | MEDLINE | ID: mdl-38761738

ABSTRACT

A novel dispersive solid-phase microextraction method based on a metal-organic framework (MIL-100(Fe)) combined with a dispersive liquid-liquid microextraction technique was proposed for the extraction and enrichment of four insecticides in beverages. The qualitative and quantitative analysis of these insecticides was conducted using HPLC-MS/MS. To optimize the extraction process, several parameters were investigated, and the main variables were optimized using CCD-based RSM. The developed method displayed a wide linear range of 1.000-1000 ng/L and R2 values >0.993 for all four calibration curves. The method demonstrated high sensitivity, with LODs and LOQs of 0.3-0.6 ng/L and 0.8-1.0 ng/L, respectively. In addition, the greenness of the proposed method was assessed using the Complex GAPI tool, and the results showed that the proposed method exhibits benefits, such as minimal usage of organic solvents and negligible matrix influence, making it a suitable method for the detection of insecticide residues in beverages.


Subject(s)
Beverages , Food Contamination , Insecticides , Liquid Phase Microextraction , Pesticide Residues , Solid Phase Microextraction , Tandem Mass Spectrometry , Liquid Phase Microextraction/methods , Chromatography, High Pressure Liquid , Insecticides/analysis , Insecticides/isolation & purification , Insecticides/chemistry , Pesticide Residues/analysis , Pesticide Residues/isolation & purification , Pesticide Residues/chemistry , Tandem Mass Spectrometry/methods , Food Contamination/analysis , Beverages/analysis , Solid Phase Microextraction/methods , Metal-Organic Frameworks/chemistry , Liquid Chromatography-Mass Spectrometry
14.
J Chromatogr A ; 1727: 464999, 2024 Jul 19.
Article in English | MEDLINE | ID: mdl-38788403

ABSTRACT

A reliable and greener alternative to the usual extraction methods is reported for the determination of pesticide residues in soybeans. This novel approach combines the classical QuEChERS extraction method with a DLLME (dispersive liquid-liquid microextraction) step, utilizing a deep eutectic solvent (DES) - camphor: hexanoic acid (1:1 molar ratio) - as the microextraction solvent. This DES has never been employed in pesticide analysis by gas chromatography-mass spectrometry of complex matrices like soybeans. A Plackett-Burman screening design was employed to optimize sample preparation variables of QuEChERS (amount of sodium chloride and magnesium sulfate, and amount of PSA and C18 sorbents) and DLLME (pH of medium, amount of sodium chloride, and volume of microextraction solvent). This design allowed for a systematic evaluation of the impact of each parameter on the method's performance. The optimized method was evaluated using a certified reference material and commercial samples of soybeans. The method exhibited high accuracy and precision for most of the analytes under study, demonstrating its applicability for pesticide residue analysis in soybeans. To assess the greenness and practicality of the developed method, the Analytical Greenness (AGREE) and Blue Applicability Grade Index (BAGI) metric systems were employed, respectively. Overall, the proposed QuEChERS-DLLME method using a DES solvent is a reliable and greener alternative to conventional extraction methods for the determination of pesticide residues in soybeans. Its high performance, coupled with its environmental friendliness, makes it a promising tool for food safety analysis.


Subject(s)
Gas Chromatography-Mass Spectrometry , Glycine max , Liquid Phase Microextraction , Pesticide Residues , Pesticide Residues/analysis , Pesticide Residues/isolation & purification , Glycine max/chemistry , Gas Chromatography-Mass Spectrometry/methods , Liquid Phase Microextraction/methods , Deep Eutectic Solvents/chemistry , Limit of Detection , Reproducibility of Results
15.
Biomed Chromatogr ; 38(7): e5883, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38712625

ABSTRACT

The application of green microextraction techniques (METs) is constantly being developed in different areas including pharmaceutical, forensic, food and environmental analysis. However, they are less used in biological monitoring of workers in occupational settings. Developing valid extraction methods and analytical techniques for the determination of occupational indicators plays a critical role in the management of workers' exposure to chemicals in workplaces. Microextraction techniques have become increasingly important because they are inexpensive, robust and environmentally friendly. This study aimed to provide a comprehensive review and interpret the applications of METs and novel sorbents and liquids in biological monitoring. Future perspectives and occupational indicators that METs have not yet been developed for are also discussed.


Subject(s)
Biological Monitoring , Liquid Phase Microextraction , Occupational Exposure , Solid Phase Microextraction , Humans , Solid Phase Microextraction/methods , Liquid Phase Microextraction/methods , Biological Monitoring/methods , Occupational Exposure/analysis , Green Chemistry Technology/methods
16.
Molecules ; 29(9)2024 Apr 30.
Article in English | MEDLINE | ID: mdl-38731560

ABSTRACT

2, 6-diisopropylaniline (2, 6-DIPA) is a crucial non-intentionally organic additive that allows the assessment of the production processes, formulation qualities, and performance variations in biodegradable mulching film. Moreover, its release into the environment may have certain effects on human health. Hence, this study developed simultaneous heating hydrolysis-extraction and amine switchable hydrophilic solvent vortex-assisted homogeneous liquid-liquid microextraction for the gas chromatography-mass spectrometry analysis of the 2, 6-DIPA additive and its corresponding isocyanates in poly(butylene adipate-co-terephthalate) (PBAT) biodegradable agricultural mulching films. The heating hydrolysis-extraction conditions and factors influencing the efficiency of homogeneous liquid-liquid microextraction, such as the type and volume of amine, homogeneous-phase and phase separation transition pH, and extraction time were investigated and optimized. The optimum heating hydrolysis-extraction conditions were found to be a H2SO4 concentration of 2.5 M, heating temperature of 87.8 °C, and hydrolysis-extraction time of 3.0 h. As a switchable hydrophilic solvent, dipropylamine does not require a dispersant. Vortex assistance is helpful to speed up the extraction. Under the optimum experimental conditions, this method exhibits a better linearity (0.0144~7.200 µg mL-1 with R = 0.9986), low limit of detection and quantification (0.0033 µg g-1 and 0.0103 µg g-1), high extraction recovery (92.5~105.4%), desirable intra- and inter-day precision (relative standard deviation less than 4.1% and 4.7%), and high enrichment factor (90.9). Finally, this method was successfully applied to detect the content of the additive 2, 6-DIPA in PBAT biodegradable agricultural mulching films, thus facilitating production process monitoring or safety assessments.


Subject(s)
Amines , Aniline Compounds , Gas Chromatography-Mass Spectrometry , Hydrophobic and Hydrophilic Interactions , Liquid Phase Microextraction , Solvents , Liquid Phase Microextraction/methods , Gas Chromatography-Mass Spectrometry/methods , Solvents/chemistry , Amines/chemistry , Amines/analysis , Aniline Compounds/chemistry , Hydrolysis , Polyesters/chemistry
17.
Food Chem ; 450: 139358, 2024 Aug 30.
Article in English | MEDLINE | ID: mdl-38631201

ABSTRACT

A new analytical methodology was proposed to determine fourteen bisphenols in honeys from different botanical origins using ultra-high performance liquid chromatography-tandem mass spectrometry. A fast, efficient, environmentally-friendly and simple sample treatment (recoveries between 81% and 116%; matrix effect <20% for all studied compounds except for bisphenol E, F and S) was proposed, which involved a solvent microextraction with acetone and a small volume/amount of 1-hexanol. Chromatographic analysis (< 15 min) was performed in a Kinetex EVO C18 column under gradient elution mode. The method was validated in terms of selectivity, limits of detection (0.2-1.5 µg/kg) and quantification (0.5-4.7 µg/kg), linearity, matrix effect, trueness, and precision (relative standard deviation <17%). Finally, thirty honey samples were analyzed, revealing the presence of residues of nine bisphenols in some of them. However, quantification was possible only in two cases for bisphenol A, with a concentration of approximately 13 µg/kg.


Subject(s)
Benzhydryl Compounds , Food Contamination , Honey , Liquid Phase Microextraction , Phenols , Tandem Mass Spectrometry , Chromatography, High Pressure Liquid , Phenols/analysis , Phenols/isolation & purification , Honey/analysis , Benzhydryl Compounds/analysis , Benzhydryl Compounds/isolation & purification , Benzhydryl Compounds/chemistry , Liquid Phase Microextraction/methods , Food Contamination/analysis
18.
Talanta ; 274: 126038, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38579419

ABSTRACT

Herein, a High-Throughput Semi-automated Emulsive Liquid-Liquid Microextraction (HTSA-ELLME) method was developed to detect Succinate Dehydrogenase Inhibitor (SDHI) fungicides in food samples via UHPLC-MS/MS. The Oil-in-Water (O/W) emulsion comprising a hydrophobic extractant and water was dilutable with the aqueous sample solution. Upon injecting the primary emulsion into the sample solution, a secondary O/W emulsion was formed, allowing SDHI fungicides to be extracted. Subsequently, a NaCl-saturated solution was injected in the secondary O/W emulsion as a demulsifier to rapidly separate the extractant, eliminating the need for centrifugation. A 12-channel electronic micropipette was used to achieve a high-throughput semi-automation of the novel sample pretreatment. The linear range was 0.003-0.3 µg L-1 with R2 > 0.998. The limit of detection was 0.001 µg L-1. The HTSA-ELLME method successfully detected SDHI fungicides in water, juice, and alcoholic beverage samples, with recoveries and relative standard deviations of 82.6-106.9% and 0.8-5.8%, respectively. Unlike previously reported liquid-liquid microextraction approaches, the HTSA-ELLME method is the first to be both high-throughput and semi-automated and may aid in designing pesticide pretreatment processes in food samples.


Subject(s)
Alcoholic Beverages , Fruit and Vegetable Juices , Fungicides, Industrial , Liquid Phase Microextraction , Tandem Mass Spectrometry , Liquid Phase Microextraction/methods , Tandem Mass Spectrometry/methods , Chromatography, High Pressure Liquid/methods , Fungicides, Industrial/analysis , Fruit and Vegetable Juices/analysis , Alcoholic Beverages/analysis , Emulsions/chemistry , Water/chemistry , Food Contamination/analysis , Automation
19.
Food Chem ; 450: 139298, 2024 Aug 30.
Article in English | MEDLINE | ID: mdl-38615532

ABSTRACT

A convenient, efficient, and green dispersive liquid-liquid microextraction based on the in situ formation of solidified supramolecular solvents combined with high performance liquid chromatography was developed for the determination of four phenylurea herbicides in liquid samples, including monuron, monolinuron, isoproturon, and chlortoluron. Herein, a novel supramolecular solvent was prepared by the in situ reaction of [P4448]Br and NH4PF6, which had the advantages of low melting point, high density, and good dispersibility. In addition, the microscopic morphology and physical properties of supramolecular solvent were characterized, and the extraction conditions were optimized. The results showed that the analytes had good linearity (R2 > 0.9998) within the linear range. The limits of detection and quantification for the four phenylurea herbicides were in the range of 0.13-0.19 µg L-1 and 0.45-0.65 µg L-1, respectively. The prepared supramolecular solvent is suitable for the efficient extraction of phenylurea herbicides in water, fruit juice, and milk.


Subject(s)
Fruit and Vegetable Juices , Herbicides , Liquid Phase Microextraction , Milk , Phenylurea Compounds , Solvents , Liquid Phase Microextraction/methods , Herbicides/chemistry , Herbicides/isolation & purification , Herbicides/analysis , Milk/chemistry , Phenylurea Compounds/isolation & purification , Phenylurea Compounds/chemistry , Phenylurea Compounds/analysis , Fruit and Vegetable Juices/analysis , Solvents/chemistry , Animals , Water Pollutants, Chemical/chemistry , Water Pollutants, Chemical/isolation & purification , Chromatography, High Pressure Liquid , Food Contamination/analysis
20.
Environ Monit Assess ; 196(5): 454, 2024 Apr 15.
Article in English | MEDLINE | ID: mdl-38622372

ABSTRACT

This work presents a sensitive and accurate analytical method for the determination of phenytoin at trace levels in domestic wastewater and synthetic urine samples by gas chromatography-mass spectrometry (GC-MS) after the metal sieve-linked double syringe liquid-phase microextraction (MSLDS-LPME) method. A metal sieve was produced in our laboratory in order to disperse water-immiscible extraction solvents into aqueous media. Univariate optimization studies for the selection of proper extraction solvent, extraction solvent volume, mixing cycle, and initial sample volume were carried out. Under the optimum MSLDS-LPME conditions, mass-based dynamic range, limit of quantitation (LOQ), limit of detection (LOD), and percent relative standard deviation (%RSD) for the lowest concentration in calibration plot were figured out to be 100.5-10964.2 µg kg-1, 150.6 µg kg-1, 45.2 µg kg-1, and 9.4%, respectively. Detection power was improved as 187.7-folds by the developed MSLDS-LPME-GC-MS system while enhancement in calibration sensitivity was recorded as 188.0-folds. In the final step of this study, the accuracy and applicability of the proposed system were tested by matrix matching calibration strategy. Percent recovery results for domestic wastewater and synthetic urine samples were calculated as 95.6-110.3% and 91.7-106.6%, respectively. These results proved the accuracy and applicability of the proposed preconcentration method, and the obtained analytical results showed the efficiency of the lab-made metal sieve apparatus.


Subject(s)
Liquid Phase Microextraction , Water Pollutants, Chemical , Gas Chromatography-Mass Spectrometry/methods , Wastewater , Phenytoin/analysis , Water Pollutants, Chemical/analysis , Environmental Monitoring/methods , Solvents/chemistry , Water/analysis , Liquid Phase Microextraction/methods , Limit of Detection
SELECTION OF CITATIONS
SEARCH DETAIL