1.
J Bodyw Mov Ther ; 39: 251-257, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38876635

ABSTRACT

OBJECTIVES: To verify the effectiveness of the use of a modified position of the Copenhagen Adduction (CA) stage 1 compared to the original position. DESIGN: Cross-sectional study. SETTING: Laboratory. PARTICIPANTS: 31 healthy men aged 23.7 ± 1.9 years with no recent or chronic general pathology. MAIN OUTCOME MEASURES: Differences between EMG amplitudes for the adductor longus (AL), rectus femoris (RF) and semi tendinous (ST) during dynamic contractions and adductor maximal isometric voluntary contraction (MIVC) force values between CA stage 1 standard and modified positions were assessed with either Wilcoxon or paired t-test. RESULTS: No significant differences were observed for EMG amplitudes of the AL (p-value = 0.724) and for the RF muscle (p-value = 0.337) and for the adductor force (p-value = 0.361) between the two positions. A significant difference was obtained for the ST (p-value<0.001) mainly explained by the adapted position of the non-dominant leg which unlocked the hip joint and generated less muscle activity in the hamstrings. CONCLUSIONS: Muscle activity of the AL muscle and adductor force being similar in both positions, the CA stage 1 modified position could be of interest for rehabilitation after adductor injury or strengthening of the adductors in elite athletes.


Subject(s)
Electromyography , Isometric Contraction , Muscle Strength Dynamometer , Muscle, Skeletal , Humans , Male , Electromyography/methods , Cross-Sectional Studies , Young Adult , Adult , Isometric Contraction/physiology , Muscle, Skeletal/physiology , Posture/physiology , Hip Joint/physiology , Quadriceps Muscle/physiology
2.
Sensors (Basel) ; 24(11)2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38894359

ABSTRACT

This study aimed to determine the absolute and relative reliability of concentric and eccentric flexion, extension, horizontal abduction, and adduction movements of the shoulder using a functional electromechanical dynamometer (FEMD). Forty-three active male university students (23.51 ± 4.72 years) were examined for concentric and eccentric strength of shoulder flexion, extension, horizontal abduction, and horizontal adduction with an isokinetic test at 0.80 m·s-1. Relative reliability was determined by intraclass correlation coefficients (ICCs) with 95% confidence intervals. Absolute reliability was quantified by the standard error of measurement (SEM) and coefficient of variation (CV). Reliability was very high to extremely high for all movements on concentric and eccentric strength measurements (ICC: 0.76-0.94, SEM: 0.63-6.57%, CV: 9.40-19.63%). The results of this study provide compelling evidence for the absolute and relative reliability of concentric and eccentric flexion, extension, horizontal abduction, and horizontal adduction shoulder isokinetic strength tests in asymptomatic adults. The mean concentric force was the most reliable strength value for all tests.


Subject(s)
Muscle Strength , Shoulder , Humans , Male , Adult , Muscle Strength/physiology , Young Adult , Shoulder/physiology , Reproducibility of Results , Range of Motion, Articular/physiology , Muscle Strength Dynamometer , Shoulder Joint/physiology , Biomechanical Phenomena/physiology , Muscle, Skeletal/physiology
3.
Clin Interv Aging ; 19: 1005-1015, 2024.
Article in English | MEDLINE | ID: mdl-38855030

ABSTRACT

Introduction: The risk of falls among the elderly significantly increases, which has become a serious public health concern. Falls can not only lead to serious complications such as fractures and brain injuries but also limit their mobility function, reducing quality of life. Foot intrinsic muscles (FIMs) are an essential part of foot core stability even overall postural stability. This study aimed to investigate the effects of aging on the function of FIMs and to explore the influence of FIMs on postural control in the elderly. Materials and Methods: 56 healthy old participants (60-75 years) and 57 healthy young participants (18-29 years) joined this study. An ergoFet dynamometer was used to determine foot muscle strength (Doming, T1, T23 and T2345), and ankle muscle strength (plantarflexion and dorsiflexion). The morphology of FIMs and extrinsic foot muscle was determined using a Doppler ultrasound system, whereas the postural stability was assessed through Limits of Stability test. Independent samples t-test was used to determine the differences in strength and morphological parameters and Spearman correlation analysis was used to determine whether an association existed between muscle strength and postural stability parameters in the elderly. Results: Compared with young adults, foot muscle strength and ankle muscle strength (Doming, T1, T23, T2345, dorsiflexion, and plantarflexion, all p <0.05) and the morphology of foot muscles (all p <0.05) were significantly reduced in the elderly. The strength of FIMs and the limit of stability (r = 0.302-0.424, all p <0.05) were significantly correlated in the elderly. Conclusion: Compared with young adults, the weakness of strength as well as the morphological decline of the intrinsic and extrinsic foot muscles were found in the elderly. In addition, a correlation was observed between FIM's strength and postural stability in the elderly, suggesting their potential role in posture stability.


Subject(s)
Foot , Muscle Strength , Muscle, Skeletal , Postural Balance , Humans , Postural Balance/physiology , Middle Aged , Female , Male , Aged , Adult , Foot/physiology , Muscle, Skeletal/physiology , Young Adult , Aging/physiology , Muscle Strength Dynamometer , Adolescent , Accidental Falls/prevention & control
4.
PLoS One ; 19(6): e0302901, 2024.
Article in English | MEDLINE | ID: mdl-38857230

ABSTRACT

OBJECTIVES: To investigate the relationships between handheld dynamometer (HHD), isokinetic and Nordic hamstrings exercise (NHE) measurements of knee flexor strength and their association with sprinting performance. DESIGN: Cross-sectional. METHODS: The relationships between HHD (prone isometric, prone break and supine break knee flexor strength tests), isokinetic and NHE peak knee flexor strength measures were examined using Pearson product correlations on 38 female footballers. A linear regression analysis was also performed for each pair of dependent variables (10 and 30 metre sprint times) and independent predictor variables (average relative peak torque for HHD, isokinetic and NHE testing). RESULTS: There were good correlations between HHD tests (r = 0.81-0.90, p < 0.001, R2 = 0.65-0.82), moderate correlations between HHD and isokinetic peak torque, (r = 0.61-0.67, p < 0.001, R2 = 0.37-0.44) and poor association between the HHD peak torques and isokinetic work (r = 0.44-0.46, p = 0.005-0.007, R2 = 0.20-0.21) and average power (r = 0.39-0.45, n = 36, p = 0.006-0.019, R2 = 0.15-0.22). There was a poor association between NHE peak torque and isokinetic total work (r = 0.34, p = 0.04, R2 = 0.12). No associations between knee flexor strength and sprint times were observed (p = 0.12-0.79, r2 = 0.002-0.086). CONCLUSIONS: Moderate to good correlations within HHD testing and poor to moderate correlations between HHD and isokinetic testing were observed. HHD knee flexor torque assessment may be useful to regularly chart the progress of hamstring rehabilitation for female footballers. Knee flexor strength assessments were not associated with sprint times in female footballers. Other aspects of knee flexor strength and sprint performance should be investigated to assist clinicians in making return to running and sprinting decisions in this population.


Subject(s)
Athletic Performance , Hamstring Muscles , Muscle Strength , Running , Humans , Female , Muscle Strength/physiology , Hamstring Muscles/physiology , Cross-Sectional Studies , Young Adult , Running/physiology , Athletic Performance/physiology , Linear Models , Adult , Muscle Strength Dynamometer , Adolescent , Torque , Knee/physiology
5.
Nutrients ; 16(12)2024 Jun 19.
Article in English | MEDLINE | ID: mdl-38931305

ABSTRACT

BACKGROUND: Handgrip strength (HGS) is an indicator of muscular strength, used in the diagnosis of sarcopenia, undernutrition, and physical frailty as well as recovery. Typically, the maximum HGS value is used; however, recent evidence suggests the exploration of new indicators provided based on the force-time curve to achieve a more comprehensive assessment of muscle function. Therefore, the objective was to identify indicators of the HGS profile beyond maximum HGS, based on force-time curves, and to systematize knowledge about their applications to various types of samples, health issues, and physical performance. METHODS: A systematic review was performed including studies whose participants' HGS was assessed with a digital or adapted dynamometer. The outcome measures were HGS profile indicators calculated from the force-time curve. RESULTS: a total of 15 studies were included, and the following indicators were identified: grip fatigue, fatigability index, fatigue rate, fatigue resistance, time to 80% maximal voluntary contraction, plateau coefficient of variability, time to maximum value, T-90%, release rate, power factor, grip work, average integrated area, endurance, cycle duration, time between cycles, maximum and minimum force-velocity, rate of grip force, final force, inflection point, integrated area, submaximal control, and response time. CONCLUSIONS: Various indicators based on the force-time curve can be assessed through digital or adapted dynamometers. Future research should analyze these indicators to understand their implications for muscle function assessment, to standardize evaluation procedures, to identify clinically relevant measures, and to clarify their implications in clinical practice.


Subject(s)
Hand Strength , Muscle Strength Dynamometer , Humans , Hand Strength/physiology , Female , Male , Muscle Fatigue/physiology , Aged , Muscle, Skeletal/physiology , Muscle Strength , Middle Aged , Sarcopenia/diagnosis , Sarcopenia/physiopathology , Time Factors , Adult
6.
J Sports Sci ; 42(9): 840-846, 2024 May.
Article in English | MEDLINE | ID: mdl-38899738

ABSTRACT

Trunk strength plays a vital role in athletic performance, rehabilitation and general health, however, current assessment methods are expensive, non-portable or unreliable. This study aimed to investigate the within- and between-session reliability, variability, standard error of measurement and minimal detectable change (MDC) of trunk strength in the sagittal (flexion and extension) and frontal planes (left and right lateral flexion) using a fixed digital dynamometer. Eighteen participants (ten men and eight women) attended two sessions separated by 7 days. Participants were fitted with a trunk harness which was secured to an immovable base via a digital dynamometer. Three maximal voluntary isometric contractions were completed across four positions (prone, supine, left-side recumbent and right-side recumbent, respectively) on a glute-hamstring raise machine. All positions demonstrated excellent reliability and low variability within session (ICC: 0.95-0.98; CV: 5-7%) and between sessions (ICC: 0.98-0.99; CV: 4-6%), across all positions. The between-session MDC ranged from 8% (prone) to 13% (right-side recumbent), translating to absolute values between 2.9 and 3.2 kg across all positions. Maximal isometric force testing using a fixed digital dynamometer provides reliable measurements of multiplanar trunk strength, providing a practical method for use in clinical practice.


Subject(s)
Isometric Contraction , Muscle Strength Dynamometer , Muscle Strength , Torso , Humans , Male , Isometric Contraction/physiology , Reproducibility of Results , Female , Muscle Strength/physiology , Young Adult , Torso/physiology , Adult , Posture/physiology , Muscle, Skeletal/physiology
7.
Nutrients ; 16(12)2024 Jun 11.
Article in English | MEDLINE | ID: mdl-38931179

ABSTRACT

BACKGROUND: Reduced muscle strength (dynapenia) and mass (atrophy) are prognostic factors in oncology. Measuring maximal handgrip strength with dynamometers is feasible but limited by the cost of the reference device (JAMAR). METHODS: A cross-sectional study was conducted on colorectal cancer outpatients treated with chemotherapy or under active surveillance in our center from September 2022 to July 2023. Accuracy, reliability, and concordance were compared for two handheld dynamometers: the JAMAR Plus (the gold-standard device) and the Camry EH101 (a low-cost index device). A simultaneous nutritional diagnosis with GLIM criteria and bioelectrical impedance analysis (BIA) was carried out. RESULTS: A total of 134 participants were included. The median of maximal strength for the JAMAR Plus had a non-significant difference of 1.4 kg from the Camry EH101. The accuracy and reliability of the devices were high. Bland-Altman analysis showed a 0.8 kg bias and -4.1 to 5.6 kg limits of agreement (LoA); a 0.1 kg bias and -5.3 to 5.4 kg LoA in men; a 1.5 kg bias and -2.2 to 5.3 kg LoA in women. In total, 29.85% of the participants were malnourished. Prevalence of dynapenia increased from 3.67% with the JAMAR Plus to 5.14% with the Camry EH101. Both devices had a moderate and significant correlation with BIA-estimated muscle mass. CONCLUSIONS: The Camry EH101 was a cost-effective alternative to JAMAR Plus in our sample.


Subject(s)
Colorectal Neoplasms , Electric Impedance , Nutritional Status , Humans , Colorectal Neoplasms/diagnosis , Male , Female , Cross-Sectional Studies , Middle Aged , Aged , Reproducibility of Results , Hand Strength , Muscle Strength Dynamometer , Nutrition Assessment , Adult
8.
J Neuromuscul Dis ; 11(4): 777-790, 2024.
Article in English | MEDLINE | ID: mdl-38788084

ABSTRACT

Background: Measurement of muscle strength and motor function is recommended in clinical trials of neuromuscular diseases, but the loss of hand strength at which motor function is impacted is not documented. Objectives: To establish the relationship between hand strength and function, and to determine the strength threshold that differentiates normal and abnormal hand function in individuals with Duchenne Muscular Dystrophy (DMD) or Spinal Muscular Atrophy (SMA). Methods: Maximal handgrip and key pinch strength were measured with the MyoGrip and MyoPinch dynamometers, respectively. Hand function was assessed using the MoviPlate, the Motor Function Measure items for distal upper limb (MFM-D3-UL) and the Cochin Hand Function Scale (CHFS). Results: Data from 168 participants (91 DMD and 77 SMA, age 6-31 years) were analyzed. Relationships between strength and function were significant (P < 0.001). Hand function was generally preserved when strength was above the strength threshold determined by Receiver-Operating Characteristic (ROC) analysis: For MFM-D3-UL, the calculated handgrip strength thresholds were 41 and 13% of the predicted strength for a healthy subject (% pred) and the key pinch strength thresholds were 42 and 26% pred for DMD and SMA, respectively. For the MoviPlate, handgrip strength thresholds were 11 and 8% pred and key pinch strength thresholds were 21 and 11% pred for DMD and SMA, respectively. For participants with sub-threshold strength, hand function scores decreased with decreasing strength. At equal % pred strength, individuals with SMA had better functional scores than those with DMD. Conclusions: Hand function is strength-dependent for most motor tasks. It declines only when strength falls below a disease-specific threshold. Therefore, therapies capable of maintaining strength above this threshold should preserve hand function.


Subject(s)
Hand Strength , Muscular Atrophy, Spinal , Muscular Dystrophy, Duchenne , Humans , Muscular Dystrophy, Duchenne/physiopathology , Hand Strength/physiology , Male , Adolescent , Child , Muscular Atrophy, Spinal/physiopathology , Adult , Young Adult , Female , Clinical Trials as Topic , Muscle Strength Dynamometer
9.
Phys Ther Sport ; 67: 167-173, 2024 May.
Article in English | MEDLINE | ID: mdl-38702203

ABSTRACT

OBJECTIVE: Assess the validity of hand-held dynamometry (HHD) and the Tindeq Progressor (TP) in assessing peak isometric knee extension torque and limb symmetry index (LSI) versus isokinetic dynamometer (IKD). DESIGN: Prospective cross-sectional study. SETTING: Laboratory. PARTICIPANTS: 31 individuals with unilateral knee disorders (21 female; 28.3 ± 11 years). MAIN OUTCOME MEASURES: Peak isometric knee extension torque; Knee extension LSI. RESULTS: Strong to almost perfect (p < 0.001) correlations (Cohen's Kappa k) with IKD were found for both devices for peak torque of the uninvolved limb (HHD [k = 0.84], TP [k = 0.91]) and involved limb (HHD [k = 0.93], TP [k = 0.98]). For LSI, moderate to strong (p < 0.001) correlations with IKD were found for HHD (k = 0.79) and TP (k = 0.89). Mean bias errors were equivalent for determining LSI (HHD = 0.02%; TP = 0.03%). Both HHD and TP were highly sensitive (96.2-100.0%) and specific (100.0%) at the 70% LSI threshold. TP showed higher sensitivity and specificity at the 90% LSI threshold. CONCLUSION: HHD and TP are valid in measuring isometric knee extension torque with the reference standard IKD. TP showed superior validity in identifying LSI. TP also shows greater specificity in identifying the 90% LSI threshold.


Subject(s)
Isometric Contraction , Knee Joint , Muscle Strength Dynamometer , Torque , Humans , Female , Cross-Sectional Studies , Male , Adult , Isometric Contraction/physiology , Prospective Studies , Knee Joint/physiopathology , Knee Joint/physiology , Young Adult , Reproducibility of Results
10.
Hand Surg Rehabil ; 43(3): 101692, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38705572

ABSTRACT

INTRODUCTION: Handgrip strength (HGS) is a strong predictor and easily applicable assessment, indicating a person's physical condition and health. However, many dynamometers are available; therefore, it is essential to ensure that the results of HGS testing using different dynamometers can be used interchangeably. The primary purpose of this study was to investigate the inter-instrument agreement and criterion validity of the Baseline BIMS Digital Grip Dynamometer in comparison with the Jamar electronic dynamometer (Jamar+). METHODS: Seventy participants, aged between 23-88 (five men and five women in each decade from 20 to 80+), performed three attempts with each dynamometer (30-sec break between attempts) in a randomized order and separated with a 5-minute break between dynamometers. Intraclass correlation coefficient (3.1), standard error of measurement and minimal detectable change were used for comparison of the strongest and average strength measured with dynamometers. Jamar+ and Baseline BIMS Digital Grip Dynamometer were new dynamometers and considered calibrated by the manufacturer. RESULTS: The overall Intraclass correlation coefficient was excellent (0.98). An average (SD) difference of 0.68 (2.2) kg (p = 0.04) was seen for the comparison of the strongest attempt for Baseline BIMS minus Jamar+, Correspondingly, for the average of three attempts, it was 0.37 (2.29, p = 0.2) kg. The standard error of measurement (%) and minimal detectable change (%) of the strongest attempt was 1.64 kg (4.2%) and 3.55 kg (9.0%), respectively. CONCLUSIONS: Findings indicate low measurement error with high agreement and criterion validity for the comparison of Baseline BIMS Digital Grip Dynamometer and Jamar+ and that results of the two dynamometers can be used interchangeably.


Subject(s)
Hand Strength , Muscle Strength Dynamometer , Humans , Hand Strength/physiology , Female , Male , Adult , Middle Aged , Aged , Young Adult , Aged, 80 and over , Reproducibility of Results
11.
Sci Rep ; 14(1): 10428, 2024 05 07.
Article in English | MEDLINE | ID: mdl-38714762

ABSTRACT

Muscle strength assessments are vital in rehabilitation, orthopedics, and sports medicine. However, current methods used in clinical settings, such as manual muscle testing and hand-held dynamometers, often lack reliability, and isokinetic dynamometers (IKD), while reliable, are not easily portable. The aim of this study was to design and validate a wearable dynamometry system with high accessibility, accuracy, and reliability, and to validate the device. Therefore, we designed a wearable dynamometry system (WDS) equipped with knee joint torque sensors. To validate this WDS, we measured knee extension and flexion strength in 39 healthy adults using both the IKD and WDS. Comparing maximal isometric torque measurements, WDS and IKD showed strong correlation and good reliability for extension (Pearson's r: 0.900; intraclass correlation coefficient [ICC]: 0.893; standard error of measurement [SEM]: 9.85%; minimal detectable change [MDC]: 27.31%) and flexion (Pearson's r: 0.870; ICC: 0.857; SEM: 11.93%; MDC: 33.07%). WDS demonstrated excellent inter-rater (Pearson's r: 0.990; ICC: 0.993; SEM: 4.05%) and test-retest (Pearson's r: 0.970; ICC: 0.984; SEM: 6.15%) reliability during extension/flexion. User feedback from 35 participants, including healthcare professionals, underscores WDS's positive user experience and clinical potential. The proposed WDS is a suitable alternative to IKD, providing high accuracy, reliability, and potentially greater accessibility.


Subject(s)
Knee Joint , Muscle Strength Dynamometer , Muscle Strength , Torque , Wearable Electronic Devices , Humans , Male , Adult , Female , Knee Joint/physiology , Muscle Strength/physiology , Reproducibility of Results , Range of Motion, Articular/physiology , Young Adult , Equipment Design
12.
PLoS One ; 19(5): e0298570, 2024.
Article in English | MEDLINE | ID: mdl-38805492

ABSTRACT

BACKGROUND: Patellofemoral pain (PFP) is a common knee complaint affecting diverse populations both acutely and chronically. Quadriceps muscle weakness is one possible aetiology, but current devices for measuring muscle strength (isokinetic dynamometer [ID] and hand-held dynamometers [HHD]) are frequently too expensive (e.g., ID) or lack reliability (e.g., HHD) for practitioners, especially in under-resourced settings. There is a need to evaluate a low-cost device to manage rehabilitation of people with PFP. METHODS: Isometric quadriceps strength of participants aged 18-35 years (total [n = 33], control group [n = 17] and PFP group [n = 16]) were evaluated on an isokinetic dynamometer and a commercially available strain gauge at baseline and after an 8-week non-standardised intervention. RESULTS: The strain gauge showed high absolute and relative reliability (intraclass correlation coefficient = 0.89-0.99; typical error of measurement = 3.9-10.4%). Clinically meaningful difference scores (12.2-45 Nm) were greater than the typical error of measurement, implying sufficient sensitivity of the strain gauge to measure true changes in isometric quadricep strength. Strong to very strong correlations were evident between the strain gauge and isokinetic dynamometer torque measurements (r = 0.88-0.90, SEE = 0.05-0.07 Nm), but slope values (ß = 0.65-0.77) indicated that torque from the strain gauge was lower than that obtained from the isokinetic dynamometer. An average systematic bias of 16.3-28.8 Nm was evident in favour of the isokinetic dynamometer, with no statistically significant between-group differences apparent between baseline and follow-up testing. CONCLUSION: The present commercially available strain gauge is reliable and sensitive enough to detect clinically meaningful differences in quadriceps strength of both healthy individuals and those with PFP. However, the strain gauge lacks validity and therefore cannot replace isokinetic dynamometry. Given the low cost and excellent reliability, the strain gauge can be a valuable tool to assess quadriceps muscle deficits and track rehabilitation progress in people with PFP.


Subject(s)
Muscle Strength Dynamometer , Muscle Strength , Quadriceps Muscle , Humans , Quadriceps Muscle/physiopathology , Quadriceps Muscle/physiology , Adult , Muscle Strength/physiology , Female , Male , Adolescent , Young Adult , Reproducibility of Results , Patellofemoral Pain Syndrome/physiopathology
13.
Med Probl Perform Art ; 39(2): 56-63, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38814124

ABSTRACT

BACKGROUND: Developmental dysplasia of the hip (DDH) is common in performing artists and other young active individuals and involves abnormalities in bony morphology of the acetabulum and proximal femur that can negatively impact walking biomechanics, muscular strength, quality of life, and sleep. Rehabilitation for hip-related conditions should target known modifiable impairments such as hip muscle strength, though a reliable method of assessment in this population remains unclear. OBJECTIVE: To determine the inter- and intra-rater reliability of hip muscle strength assessments using handheld dynamometry (HHD) in young active circus artists with DDH. METHODS: Reliability of hip strength in all planes was assessed using HHD in 21 adult performing circus arts students (mean age 21.3 yrs [3.2]; 13 M, 5 F, 3 NB) with symptomatic radiologically and clinically diagnosed hip dysplasia. The reliability of average peak force and absolute peak force were expressed for each position tested. Reliability was assessed using intraclass correlation coefficients (ICC) with standard error of measurement (SEM) and minimal detectable change (MDC) values calculated to improve clinical interpretability. RESULTS: Good to excellent inter-rater reliability resulted for all hip muscle strength testing positions, ICC=0.88 (95%CI 0.70 to 0.95) to ICC=0.97 (0.92 to 0.99), except average peak hip flexion strength, ICC=0.71 (0.28 to 0.88). Absolute peak hip abduction, ICC=0.77 (0.16 to 0.94), and adduction strength, ICC=0.72 (-0.55 to 0.92), demonstrated the lowest intra-rater reliability. Transverse plane strength measures (rotation) produced the lowest SEM and MDC values followed by the frontal plane (abduction/adduction) and sagittal plane (flexion/extension). CONCLUSION: HHD is an appropriate and reliable method to assess hip muscle strength in circus artists with DDH.


Subject(s)
Muscle Strength , Humans , Muscle Strength/physiology , Reproducibility of Results , Female , Male , Young Adult , Hip Joint/physiopathology , Muscle Strength Dynamometer , Adult , Developmental Dysplasia of the Hip/physiopathology
14.
Turk J Med Sci ; 54(1): 136-147, 2024.
Article in English | MEDLINE | ID: mdl-38812618

ABSTRACT

Background/aim: Isokinetic strength assessment of the rotator cuff muscle is frequently applied in a variety of shoulder postures, but none of these consider muscular architecture, which is one of the most important aspects of improving strength development. This study aimed to examine the test and retest reliability and validity of the muscle architecture-based position (MABP), which is 25° abduction and 20° external rotation, in healthy subjects to be able to select a better isokinetic assessment position for shoulder rotator cuff muscles. Materials and methods: A total of 54 healthy males with a mean age of 21.0 ± 1.2 years and mean body mass index of 22.8 ± 1.7 kg/m2 completed an isokinetic measurement session. All of the tests were performed on an IsoMed 2000 isokinetic dynamometer concentrically and eccentrically for both upper limbs at 60°/s angular velocity. All of the participants completed 3 measurement sessions: the first represented the isokinetic testing and was performed in the scapular neutral position (SNP) (45° shoulder flexion and abduction), the second represented the MABP (25° abduction and 20° ER) for shoulder rotator cuff muscles, and the third represented the test and retest of the MABP. Results: The correlations between the 2 techniques for assessing concurrent validity ranged from 0.908 to 0.994. The values obtained from the MABP were higher than those obtained in the SNP. There was no systematic bias for any measurements between the MABP and the retest of the MABP (p > 0.05). The intraclass correlation coefficients representing the test and retest reliability results for each variable measured with the MABP was higher than 0.98 and this value was considered as excellent reliability. Conclusion: In conclusion, the MABP can be used to assess the isokinetic strength of the rotator cuff muscles safely and confidently, with increased quantities of force being released and measurement at optimal muscle tension.


Subject(s)
Muscle Strength , Rotator Cuff , Humans , Male , Rotator Cuff/physiology , Reproducibility of Results , Muscle Strength/physiology , Young Adult , Muscle Strength Dynamometer , Range of Motion, Articular/physiology , Adult , Healthy Volunteers , Posture/physiology
15.
Chronobiol Int ; 41(5): 709-724, 2024 May.
Article in English | MEDLINE | ID: mdl-38722075

ABSTRACT

We have investigated the magnitude of circadian variation in Isokinetic and Isometric strength of the knee extensors and flexors, as well as back squat and bench press performance using the MuscleLab force velocity transducer. Ten resistance-trained males (mean±SD: age 21.5 ± 1.1 years; body mass 78.3 ± 5.2 kg; height 1.71 ± 0.07 m) underwent a) three to four familiarization sessions on each dynamometer and b) four sessions at different times of day (03:00, 09:00, 15:00 and 21:00 h). Each session was administered in a counterbalanced order and included a period when Perceived onset of mood states (POMS), then rectal and muscle temperature (Trec, Tm) was measured at rest, after which a 5-min standardized 150 W warm-up was performed on a cycle ergometer. Once completed, Isokinetic (60 and 240°·s-1 for extension and flexion) and Isometric dynamometry with peak torque (PT), time-to-peak-torque (tPT) and peak force (PF) and % activation was measured. Lastly, Trec and Tm were measured before the bench press (at 30, 50 and 70 kg) and back squat (at 40, 60 and 80 kg) exercises. A linear encoder was attached to an Olympic bar used for the exercises and average force (AF), peak velocity (PV) and time-to-peak-velocity (tPV) were measured (MuscleLab software; MuscleLab Technology, Langesund, Norway) during the concentric phase of the movements. Five-min recovery was allowed between each set with three repetitions being completed. General linear models with repeated measures and cosinor analysis were used to analyse the data. Values for Trec and Tm at rest were higher in the evening compared to morning values (Acrophase Φ: 16:35 and 17:03 h, Amplitude A: 0.30 and 0.23°C, Mesor M: 36.64 and 37.43°C, p < 0.05). Vigor, happy and fatigue mood states responses showed Φ 16:11 and 16:03 h and 02:05 h respectively. Circadian rhythms were apparent for all variables irrespective of equipment used where AF, PF and PT values peaked between 16:18 and 18:34 h; PV, tPV and tPT peaked between 05:54 and 08:03 h (p < 0.05). In summary, circadian rhythms in force output (force, torque, power, and velocity) were shown for isokinetic, isometric dynamometers and complex multi-joint movements (using a linear encoder); where tPV and tPT occur in the morning compared to the evening. Circadian rhythms in strength can be detected using a portable, low-cost instrument that shows similar cosinor characteristics as established dynamometers. Hence, muscle-strength can be measured in a manner that is more directly transferable to the world of athletic and sports performance.


Subject(s)
Circadian Rhythm , Muscle Strength , Muscle, Skeletal , Humans , Male , Circadian Rhythm/physiology , Young Adult , Muscle, Skeletal/physiology , Muscle Strength/physiology , Isometric Contraction/physiology , Muscle Strength Dynamometer , Adult , Torque , Exercise/physiology
16.
PLoS One ; 19(5): e0303648, 2024.
Article in English | MEDLINE | ID: mdl-38781271

ABSTRACT

The aim of the study was to assess the external and internal compatibility of the Biometrics E-LINK EP9 evaluation system device in the area of hand grip and pinch strength in the Polish population. The testing of hand grip and pinch strength was carried out among 122 healthy students. Two examiners performed hand grip and pinch strength measurements with a Biometrics E-LINK EP9 evaluation system device. Measurements were made for the right and left hands. The same people were tested again two weeks later, under the same conditions. The scores of one rater on the first and second tests were compared for reproducibility, and the scores of the two raters were compared to assess the reliability of the instrument. The measurements were found to be highly consistent both between the investigators and between the tests in the hand grip dynamometer test. The findings show high values of the Pearson's correlation coefficient equal or close to 1, as well as the interclass correlation coefficient (ICC) >0.9. Analysis of pinch strength measurements performed using the pinchmeter also found high values of the Pearson's correlation coefficient close to 1, as well as the interclass correlation coefficient >0.9; this reflects high agreement between the measurements performed by two investigators as well as assessments performed by one investigator at time intervals. These findings were confirmed by analyses performed using Bland-Altman plots. The measurements made with the Biometrics E-link EP9 evaluation system show high internal and external consistency in hand grip and pinch strength assessment. Biometrics E-link EP9 can be recommended for daily clinical practice.


Subject(s)
Hand Strength , Pinch Strength , Humans , Hand Strength/physiology , Male , Female , Poland , Prospective Studies , Pinch Strength/physiology , Reproducibility of Results , Adult , Young Adult , Biometry/methods , Biometry/instrumentation , Muscle Strength Dynamometer
17.
PLoS One ; 19(5): e0301872, 2024.
Article in English | MEDLINE | ID: mdl-38776288

ABSTRACT

BACKGROUND: The current clinical gold standard for assessing isometric quadriceps muscle strength is an isokinetic dynamometer (IKD). However, in clinics without an IKD, clinicians default to using handheld dynamometers (HHD), which are less reliable and accurate than the IKD, particularly for large muscle groups. A novel device (ND) was developed that locks the weight stack of weight machines, and measures forces applied to the machine, turning this equipment into an isometric dynamometer. The objectives of this study were to characterize the test-retest reliability of the ND, determine the within-day and between-days inter-rater reliability and concurrent validity compared with that of the HHD, in healthy volunteers (HV) and individuals with knee osteoarthritis (OA) for measuring knee extensors isometric muscle force. MATERIALS AND METHODS: 29 healthy (age = 28.4 ± 7.4 years) and 15 knee OA (age = 37.6 ± 13.4 years) participants completed three maximum force isometric strength testing trials on dominant side knee extensor muscles on three devices (ND, HHD, and IKD) in two separate sessions by two raters. The maximum force (Fmax) produced, and the force-time series were recorded. Reliability and validity were assessed using Intraclass Correlation Coefficient (ICC), Bland-Altman Plots, Pearson's r, and cross-correlations. RESULTS: The ND demonstrated excellent test-retest reliability (ICC2,3 = 0.97). The within-day (ICC2,3 = 0.88) and between-day inter-rater reliability (ICC2,3 = 0.87) was good for HHD. The ND showed excellent within-day (ICC2,3 = 0.93) and good between-day (ICC2,3 = 0.89) inter-rater reliability. The Bland-Altman analysis revealed HHD systematic bias and underestimation of force particularly with quadriceps force values exceeding 450 N. Mean differences were found in maximum force between HHD vs. IKD (MDabs = 58 N, p < .001) but not the HHD vs. ND (MDabs = 24 N, p = .267) or ND vs. IKD (MDabs = 34 N, p = .051). The concurrent validity of Fmax (r = 0.81) and force-time curve correlation (0.96 ± 0.05) were the highest between the ND and IKD. CONCLUSIONS: The ND's test-retest reliability and concurrent validity make it a potential strength assessment tool with utility in physical therapy and fitness settings for large muscle groups such as the knee extensors.


Subject(s)
Isometric Contraction , Muscle Strength Dynamometer , Muscle Strength , Humans , Adult , Male , Female , Reproducibility of Results , Muscle Strength/physiology , Middle Aged , Isometric Contraction/physiology , Osteoarthritis, Knee/physiopathology , Quadriceps Muscle/physiology , Young Adult , Knee Joint/physiology , Knee Joint/physiopathology , Knee/physiology , Knee/physiopathology
18.
Narra J ; 4(1): e303, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38798840

ABSTRACT

Trunk muscles maintain steady effort with adequate strength and endurance. When the muscle performance is subpar, it might cause lower back discomfort. No reference for trunk strength and endurance has been established previously. The aim of this study was to determine the normative reference values for dynamometric and non-dynamometric tests in people with various body fat percentages. Two hundred sixty-four participants aged 19-40 years old were recruited in this cross-sectional study. The Siri equation was used to calculate the individuals body fat proportions, which were divided into normal, high, and very high body fat for men and women. The Modified Sorenson's and the Back-Leg-Chest Dynamometric tests were utilized to measure muscular performance. The means of strength in females with normal, high, and very high body fat percentages were 27.39, 25.75, and 25.37 N/m2, respectively. The males in the same category had the means of 56.48, 51.79, and 60.17 N/m2, respectively. The highest mean of endurance in females was in those with normal body fat percentage (42.28), so did males (71.02). Our findings suggest that males had higher trunk muscle strength and endurance than females, and normal-body-fat individuals had the greatest endurance regardless of gender.


Subject(s)
Muscle Strength , Humans , Female , Male , Adult , Cross-Sectional Studies , Muscle Strength/physiology , Reference Values , Sex Factors , Adipose Tissue , Muscle Strength Dynamometer , Torso/physiology , Physical Endurance/physiology , Young Adult
19.
Foot (Edinb) ; 59: 102095, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38614012

ABSTRACT

Despite the growing interest, information regarding the psychometric properties of maximal voluntary isometric toe plantarflexion force and rate of force development (RFD) is lacking. Hence, we investigate the test-retest reliability and measurement error of these outcome measurement instruments measured with a custom-built dynamometer. Twenty-six healthy adults participated in a crossed design with four sessions separated by 5-7 days. RFD was quantified using manual onset and calculating the impulse and the slope in the following time windows: 0-50 ms, 0-100 ms, 0-150 ms, 0-200 ms, 0-250 ms. We estimated the systematic bias of the mean, the intraclass correlation coefficient (ICC) and standard error of measurement (SEM) from the agreement and consistency models. The ICC and the SEM agreement for maximal voluntary isometric toe plantarflexion force along the perpendicular axis were respectively 0.87 (95%CI: 0.76, 0.93) and 27 N (22, 32), while along the resultant of the perpendicular and anterior posterior axis they were 0.85 (0.73, 0.92) and 29 N (23, 35). The results of the consistency model were similar as the estimated variance for session was closer to zero. A systematic bias of the mean between session 1 and 3 was found. For the RFD variables, the ICC agreement ranged from 0.35 to 0.65. The measurement process was found to be reliable to assess maximal voluntary isometric toe plantarflexion force but not RFD. However, a familiarization session is mandatory and these results need to be confirmed in less coordinated (e.g. aging population) individuals.


Subject(s)
Isometric Contraction , Muscle Strength Dynamometer , Toes , Humans , Male , Female , Reproducibility of Results , Adult , Isometric Contraction/physiology , Toes/physiology , Young Adult , Muscle, Skeletal/physiology , Muscle Strength/physiology , Healthy Volunteers
20.
PLoS One ; 19(4): e0302474, 2024.
Article in English | MEDLINE | ID: mdl-38669272

ABSTRACT

Evaluation of muscle strength imbalance can be an important element in optimizing the training process of soccer players. The purpose of the study was to examine isokinetic peak torque (PT) and total work (TW) exerted by both knee extensors (quadriceps or Q) and flexors (hamstrings or H), intra-limb imbalance and the magnitude and direction of inter-limb asymmetry in top elite senior (n = 109) and junior (n = 74) soccer players. An isokinetic dynamometry was used to measure maximum peak torque of quadriceps (PT-Q) and hamstrings (PT-H) at an angular velocity of 60° ·s-1, as well as the total work for extensors (TW-Q) and flexors (TW-H) at an angular velocity of 240° ·s-1 in the dominant (DL) and non-dominant leg (NDL) during concentric muscle contraction. Intra-limb imbalance and inter-limb asymmetries were calculated using a standard equation. Statistical analysis using t-test and Mann-Whitney U-test revealed: (a) no differences (p > 0.05) between groups for PT-Q and PT-H, (b) greater strength levels (p < 0.05) for TW-Q and TW-H of senior players than juniors, and (c) no differences (p > 0.05) between groups for intra-limb imbalance and inter-limb asymmetry. Additionally, Pearson's chi-kwadrat (χ2) analysis showed no differences (p > 0.05) between groups for intra-limb imbalance and inter-limb asymmetry in relation to the 'normative' values accepted in the literature that indicate an increase in the risk of knee injury. This study shows that isokinetic assessment can be an important tool to identify imbalances/asymmetries and to develop strategies to reduce the risk of muscle injury.


Subject(s)
Muscle Strength , Soccer , Torque , Soccer/physiology , Humans , Muscle Strength/physiology , Male , Young Adult , Adolescent , Adult , Muscle Contraction/physiology , Athletes , Quadriceps Muscle/physiology , Muscle, Skeletal/physiology , Hamstring Muscles/physiology , Muscle Strength Dynamometer