Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 1.110
Filter
1.
Cell Mol Life Sci ; 81(1): 267, 2024 Jun 17.
Article in English | MEDLINE | ID: mdl-38884678

ABSTRACT

Neutralizing antibodies are considered a correlate of protection against severe human respiratory syncytial virus (HRSV) disease. Currently, HRSV neutralization assays are performed on immortalized cell lines like Vero or A549 cells. It is known that assays on these cell lines exclusively detect neutralizing antibodies (nAbs) directed to the fusion (F) protein. For the detection of nAbs directed to the glycoprotein (G), ciliated epithelial cells expressing the cellular receptor CX3CR1 are required, but generation of primary cell cultures is expensive and labor-intensive. Here, we developed a high-throughput neutralization assay based on the interaction between clinically relevant HRSV grown on primary cells with ciliated epithelial cells, and validated this assay using a panel of infant sera. To develop the high-throughput neutralization assay, we established a culture of differentiated apical-out airway organoids (Ap-O AO). CX3CR1 expression was confirmed, and both F- and G-specific monoclonal antibodies neutralized HRSV in the Ap-O AO. In a side-by-side neutralization assay on Vero cells and Ap-O AO, neutralizing antibody levels in sera from 125 infants correlated well, although titers on Ap-O AO were consistently lower. We speculate that these lower titers might be an actual reflection of the neutralizing antibody capacity in vivo. The organoid-based neutralization assay described here holds promise for further characterization of correlates of protection against HRSV disease.


Subject(s)
Antibodies, Neutralizing , CX3C Chemokine Receptor 1 , Neutralization Tests , Organoids , Respiratory Syncytial Virus Infections , Respiratory Syncytial Virus, Human , Humans , Respiratory Syncytial Virus, Human/immunology , Antibodies, Neutralizing/immunology , Organoids/metabolism , Organoids/immunology , Organoids/virology , Organoids/cytology , Animals , Neutralization Tests/methods , Chlorocebus aethiops , Vero Cells , Respiratory Syncytial Virus Infections/immunology , Respiratory Syncytial Virus Infections/virology , CX3C Chemokine Receptor 1/metabolism , CX3C Chemokine Receptor 1/immunology , Antibodies, Viral/immunology , Viral Fusion Proteins/immunology , Viral Fusion Proteins/metabolism , Infant , Epithelial Cells/metabolism , Epithelial Cells/immunology , Epithelial Cells/virology , Antibodies, Monoclonal/immunology
2.
J Virol Methods ; 328: 114959, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38788979

ABSTRACT

In Foot-and-mouth disease (FMD) enzootic countries, periodic vaccination is the key tool in controlling the disease incidence. Active seromonitoring of the vaccinated population is critical to assess the impact of vaccination. Virus neutralization test (VNT) and enzyme-linked immunosorbent assays (ELISA) are commonly used for antibody detection. Assays like liquid phase blocking ELISA (LPBE) or solid phase competition ELISA (SPCE) are preferred as they do not require handling of live FMDV and are routinely used for seromonitoring or for vaccine potency testing; however, false positives are high in LPBE. Here we report, a monoclonal antibody (mAb) based SPCE as a potential alternate assay for antibody titration. From a panel of 12 mAbs against FMDV serotype A, two mAbs were chosen for the development of SPCE. Based on a set of 453 sera, it was demonstrated that mAb 2C4G11, mAb 6E8D11and polyclonal antibody (pAb) based SPCE had a relative sensitivity of 86.1, 86.1 and 80.3 %; and specificity of 99.6, 99.1 and 99.1 %, respectively. The correlation, repeatability, and level of agreement of the assays were high demonstrating the potential use of mAb in large scale surveillance studies and regular vaccine potency testing.


Subject(s)
Antibodies, Monoclonal , Antibodies, Viral , Enzyme-Linked Immunosorbent Assay , Foot-and-Mouth Disease Virus , Foot-and-Mouth Disease , Sensitivity and Specificity , Serogroup , Enzyme-Linked Immunosorbent Assay/methods , Antibodies, Viral/blood , Antibodies, Viral/immunology , Foot-and-Mouth Disease Virus/immunology , Animals , Antibodies, Monoclonal/immunology , Foot-and-Mouth Disease/diagnosis , Foot-and-Mouth Disease/immunology , Foot-and-Mouth Disease/virology , Cattle , Neutralization Tests/methods
3.
Front Cell Infect Microbiol ; 14: 1341332, 2024.
Article in English | MEDLINE | ID: mdl-38746783

ABSTRACT

Introduction: The Crimean-Congo hemorrhagic fever virus (CCHFV), the most geographically widespread tick-borne virus, is endemic in Africa, Eastern Europe and Asia, with infection resulting in mortality in up to 30% of cases. Currently, there are no approved vaccines or effective therapies available for CCHF. The CCHFV should only be manipulated in the BSL-4 laboratory, which has severely hampered basic seroprevalence studies. Methods: In the present study, two antibody detection methods in the forms of an enzyme-linked immunosorbent assay (ELISA) and a surrogate virus neutralization test (sPVNT) were developed using a recombinant glycoprotein (rGP) and a vesicular stomatitis virus (VSV)-based virus bearing the CCHFV recombinant glycoprotein (rVSV/CCHFV) in a biosafety level 2 (BSL-2) laboratory, respectively. Results: The rGP-based ELISA and rVSV/CCHFV-based sVNT were established by using the anti-CCHFV pre-GC mAb 11E7, known as a broadly cross-reactive, potently neutralizing antibody, and their applications as diagnostic antigens were validated for the specific detection of CCHFV IgG and neutralizing antibodies in experimental animals. In two tests, mAb clone 11E7 (diluted at 1:163840 or 512) still displayed positive binding and neutralization, and the presence of antibodies (IgG and neutralizing) against the rGP and rVSV/CCHFV was also determined in the sera from the experimental animals. Both mAb 11E7 and animal sera showed a high reactivity to both antigens, indicating that bacterially expressed rGP and rVSV/CCHFV have good immunoreactivity. Apart from establishing two serological testing methods, their results also demonstrated an imperfect correlation between IgG and neutralizing antibodies. Discussion: Within this limited number of samples, the rGP and rVSV/CCHFV could be safe and convenient tools with significant potential for research on specific antibodies and serological samples.


Subject(s)
Antibodies, Neutralizing , Antibodies, Viral , Enzyme-Linked Immunosorbent Assay , Hemorrhagic Fever Virus, Crimean-Congo , Hemorrhagic Fever, Crimean , Immunoglobulin G , Neutralization Tests , Hemorrhagic Fever Virus, Crimean-Congo/immunology , Antibodies, Neutralizing/blood , Antibodies, Neutralizing/immunology , Antibodies, Viral/blood , Antibodies, Viral/immunology , Neutralization Tests/methods , Enzyme-Linked Immunosorbent Assay/methods , Immunoglobulin G/blood , Immunoglobulin G/immunology , Hemorrhagic Fever, Crimean/diagnosis , Hemorrhagic Fever, Crimean/immunology , Animals , Humans , Glycoproteins/immunology , Serologic Tests/methods , Recombinant Proteins/immunology , Mice , Antibodies, Monoclonal/immunology
4.
Methods Mol Biol ; 2808: 209-224, 2024.
Article in English | MEDLINE | ID: mdl-38743373

ABSTRACT

The plaque reduction neutralization test (PRNT) and the enzyme-linked immunosorbent assay (ELISA) are both widely used to assess immunity to infectious diseases such as measles, but they use two different measurement principles: ELISA measures the ability of antibodies to bind to virus components, while the PRNT detects the aptitude of antibodies to prevent the infection of a susceptible cell. As a result, detection of measles virus (MV) neutralizing antibodies is the gold standard for assessing immunity to measles. However, the assay is laborious and requires experience and excellent technical skills. In addition, the result is only available after several days. Therefore, the classical PRNT is not suitable for high-throughput testing. By using an immunocolorimetric assay (ICA) to detect MV-infected cells, the standard PRNT has been developed into a focus reduction neutralization test (FRNT). This assay is faster and has improved specificity. The FRNT described here is extremely useful when immunity to measles virus needs to be assessed in patients with a specific medical condition, such as immunocompromised individuals in whom presumed residual immunity needs to be assessed. The FRNT is not generally recommended for use with large numbers of specimens, such as in a seroprevalence study.


Subject(s)
Antibodies, Neutralizing , Antibodies, Viral , Measles virus , Measles , Neutralization Tests , Neutralization Tests/methods , Measles virus/immunology , Measles/immunology , Measles/diagnosis , Measles/virology , Humans , Antibodies, Neutralizing/immunology , Antibodies, Neutralizing/blood , Antibodies, Viral/immunology , Chlorocebus aethiops , Animals , Vero Cells , Viral Plaque Assay/methods , Enzyme-Linked Immunosorbent Assay/methods
5.
Med Microbiol Immunol ; 213(1): 6, 2024 May 09.
Article in English | MEDLINE | ID: mdl-38722338

ABSTRACT

To date, there is no licensed vaccine for Middle East respiratory syndrome coronavirus (MERS-CoV). Therefore, MERS-CoV is one of the diseases targeted by the Coalition for Epidemic Preparedness Innovations (CEPI) vaccine development programs and has been classified as a priority disease by the World Health Organization (WHO). An important measure of vaccine immunogenicity and antibody functionality is the detection of virus-neutralizing antibodies. We have developed and optimized a microneutralization assay (MNA) using authentic MERS-CoV and standardized automatic counting of virus foci. Compared to our standard virus neutralization assay, the MNA showed improved sensitivity when analyzing 30 human sera with good correlation of results (Spearman's correlation coefficient r = 0.8917, p value < 0.0001). It is important to use standardized materials, such as the WHO international standard (IS) for anti-MERS-CoV immunoglobulin G, to compare the results from clinical trials worldwide. Therefore, in addition to the neutralizing titers (NT50 = 1384, NT80 = 384), we determined the IC50 and IC80 of WHO IS in our MNA to be 0.67 IU/ml and 2.6 IU/ml, respectively. Overall, the established MNA is well suited to reliably quantify vaccine-induced neutralizing antibodies with high sensitivity.


Subject(s)
Antibodies, Neutralizing , Antibodies, Viral , Middle East Respiratory Syndrome Coronavirus , Neutralization Tests , Middle East Respiratory Syndrome Coronavirus/immunology , Humans , Neutralization Tests/methods , Antibodies, Neutralizing/blood , Antibodies, Neutralizing/immunology , Antibodies, Viral/blood , Coronavirus Infections/prevention & control , Coronavirus Infections/immunology , Coronavirus Infections/diagnosis , Animals , Inhibitory Concentration 50 , Sensitivity and Specificity
6.
Hum Vaccin Immunother ; 20(1): 2330168, 2024 Dec 31.
Article in English | MEDLINE | ID: mdl-38567541

ABSTRACT

Human papillomavirus (HPV) vaccines, primarily relying on neutralizing antibodies, have proven highly effective. Recently, HPV-specific antibodies have been detected in the female genital tract secretions captured by first-void urine (FVU), offering a minimally invasive diagnostic approach. In this study, we investigated whether HPV16-specific antibodies present in FVU samples retain their neutralizing capacity by using pseudovirion-based neutralization assays. Paired FVU and serum samples (vaccinated n = 25, unvaccinated n = 25, aged 18-25) were analyzed using two orthogonal pseudovirion-based neutralization assays, one using fluorescence microscopy and the other using luminescence-based spectrophotometry. Results were compared with HPV16-specific IgG concentrations and correlations between neutralizing antibodies in FVU and serum were explored. The study demonstrated the presence of neutralizing antibodies in FVU using both pseudovirion-based neutralization assays, with the luminescence-based assay showing higher sensitivity for FVU samples, while the fluorescence microscopy-based assay exhibited better specificity for serum and overall higher reproducibility. High Spearman correlation values were calculated between HPV16-IgG and HPV16-neutralizing antibodies for both protocols (rs: 0.54-0.94, p < .001). Significant Spearman correlations between FVU and serum concentrations were also established for all assays (rs: 0.44-0.91, p < .01). This study demonstrates the continued neutralizing ability of antibodies captured with FVU, supporting the hypothesis that HPV vaccination may reduce autoinoculation and transmission risk to the sexual partner. Although further protocol optimizations are warranted, these findings provide a foundation for future research and larger cohort studies that could have implications for the optimal design, evaluation, and implementation of HPV vaccination programs.


Subject(s)
Papillomavirus Infections , Papillomavirus Vaccines , Humans , Female , Adolescent , Young Adult , Adult , Papillomavirus Infections/prevention & control , Reproducibility of Results , Antibodies, Viral , Antibodies, Neutralizing , Neutralization Tests/methods , Genitalia, Female , Human papillomavirus 16 , Immunoglobulin G
7.
Cytometry A ; 105(6): 446-457, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38624015

ABSTRACT

The COVID-19 pandemic caused by the SARS-CoV-2 virus has highlighted the need for serological assays that can accurately evaluate the neutralizing efficiency of antibodies produced during infection or induced by vaccines. However, conventional assays often require the manipulation of live viruses on a level-three biosafety (BSL3) facility, which presents practical and safety challenges. Here, we present a novel, alternative assay that measures neutralizing antibodies (NAbs) against SARS-CoV-2 in plasma using flow cytometry. This assay is based on antibody binding to the S protein and has demonstrated precision in both intra- and inter-assay measurements at a dilution of 1:50. The cut-off was determined using Receiver Operating Characteristic (ROC) analysis and the value of 36.01% has shown high sensitivity and specificity in distinguishing between pre-pandemic sera, COVID-19 patients, and vaccinated individuals. The efficiency significantly correlates with the gold standard test, PRNT. Our new assay offers a safe and efficient alternative to conventional assays for evaluating NAbs against SARS-CoV-2.


Subject(s)
Antibodies, Neutralizing , Antibodies, Viral , COVID-19 , Flow Cytometry , SARS-CoV-2 , Humans , Flow Cytometry/methods , SARS-CoV-2/immunology , Antibodies, Neutralizing/immunology , Antibodies, Neutralizing/blood , COVID-19/immunology , COVID-19/diagnosis , COVID-19/virology , Antibodies, Viral/immunology , Antibodies, Viral/blood , Spike Glycoprotein, Coronavirus/immunology , Neutralization Tests/methods , COVID-19 Serological Testing/methods , Sensitivity and Specificity , Male , Female
8.
J Virol Methods ; 327: 114945, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38649070

ABSTRACT

As variants of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) continue to emerge, assessment of vaccine immunogenicity remains a critical factor to support continued vaccination. To this end, an in vitro microneutralization (MN50) assay was validated to quantitate SARS-CoV-2 neutralizing antibodies against prototype and variant strains (Beta, Delta, Omicron BA.1, Omicron BA.5, and XBB.1.5) in human serum. For the prototype strain, the MN50 assay met acceptance criteria for inter-/intra-assay precision, specificity, linearity, and selectivity. The assay was robust against changes to virus/serum incubation time, cell seeding density, virus content per well, cell passage number, and serum interference. Analyte in serum samples was stable up to five freeze/thaw cycles and for up to 12 months of storage at -80 ± 10 °C. Similar results were observed for the variant-adapted MN50 assays. The conversion factor to convert assay result units to WHO international standard units (IU/mL) was determined to be 0.62 for the prototype strain. This MN50 assay will be useful for vaccine immunogenicity analyses in clinical trial samples, enabling assessment of vaccine immunogenicity for ancestral and variant strains as variant-adapted vaccines are developed.


Subject(s)
Antibodies, Neutralizing , Antibodies, Viral , COVID-19 Vaccines , COVID-19 , Immunogenicity, Vaccine , Neutralization Tests , SARS-CoV-2 , Humans , Antibodies, Neutralizing/blood , Antibodies, Neutralizing/immunology , SARS-CoV-2/immunology , SARS-CoV-2/genetics , Neutralization Tests/methods , Antibodies, Viral/blood , COVID-19 Vaccines/immunology , COVID-19/prevention & control , COVID-19/immunology , COVID-19/diagnosis , Sensitivity and Specificity , Animals , Reproducibility of Results
9.
J Appl Lab Med ; 9(4): 741-751, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38531067

ABSTRACT

BACKGROUND: Although age negatively correlates with vaccine-induced immune responses, whether the vaccine-induced neutralizing effect against variants of concern (VOCs) substantially differs across age remains relatively poorly explored. In addition, the utility of commercial binding assays developed with the wild-type SARS-CoV-2 for predicting the neutralizing effect against VOCs should be revalidated. METHODS: We analyzed 151 triple-vaccinated SARS-CoV-2-naïve individuals boosted with BNT162b2 (Pfizer-BioNTech). The study population was divided into young adults (age < 30), middle-aged adults (30 ≤ age < 60), and older adults (age ≥ 60). The plaque reduction neutralization test (PRNT) titers against Delta (B.1.617.2) and Omicron (B.1.1.529) variants were compared across age. Antibody titers measured with commercial binding assays were compared with PRNT titers. RESULTS: Age-related decline in neutralizing titers was observed for both Delta and Omicron variants. Neutralizing titers for Omicron were lower than those against Delta in all ages. The multiple linear regression model demonstrated that duration from third dose to sample collection and vaccine types were also significant factors affecting vaccine-induced immunity along with age. The correlation between commercial binding assays and PRNT was acceptable for all age groups with the Delta variant, but relatively poor for middle-aged and older adults with the Omicron variant due to low titers. CONCLUSIONS: This study provides insights into the age-related dynamics of vaccine-induced immunity against SARS-CoV-2 VOCs, corroborating the need for age-specific vaccination strategies in the endemic era where new variants continue to evolve. Moreover, commercial binding assays should be used cautiously when estimating neutralizing titers against VOCs, particularly Omicron.


Subject(s)
Antibodies, Neutralizing , Antibodies, Viral , BNT162 Vaccine , COVID-19 , SARS-CoV-2 , Humans , Antibodies, Neutralizing/immunology , Antibodies, Neutralizing/blood , SARS-CoV-2/immunology , Adult , Middle Aged , COVID-19/immunology , COVID-19/prevention & control , COVID-19/virology , Male , Female , Antibodies, Viral/blood , Antibodies, Viral/immunology , BNT162 Vaccine/immunology , BNT162 Vaccine/administration & dosage , Aged , Age Factors , Young Adult , Neutralization Tests/methods , COVID-19 Vaccines/immunology , COVID-19 Vaccines/administration & dosage
10.
Sci Rep ; 14(1): 1421, 2024 01 16.
Article in English | MEDLINE | ID: mdl-38228735

ABSTRACT

Diagnosis of SARS-CoV-2 virus is mainly based on direct detection. Determination of specific antibodies has been used mostly for epidemiological reasons. However, select immunoassays showed good correlation to plaque reduction virus neutralization test (PRNT) in smaller patient cohorts, which suggests their potential as predictors of virus neutralization titer. A total of 3,699 samples from Covid-19 patients were included in the multicentric study performed in the Czech Republic. Anti-SARS-CoV-2 antibody levels were evaluated by 8 commercial antibody assays. Simultaneously, PRNT evaluations were performed with the SARS-CoV-2 B.1.258 variant. All immunoassays showed an overall high true positive diagnostic value ranging from 79.17 to 98.04%. Several commercial EIA methods showed highly positive correlation between the assay results and PRNT levels, e.g., Liaison CoV-2 TrimericS IgG DiaSorin (Spearman r = 0.8833; Architect SASRS-CoV-2 IgG Abbott (r = 0.7298); NovaLisa SARS-CoV-2 IgG NovaTec (r = 0.7103) and Anti-SARS-CoV-2 ELISA IgG Euroimmun (r = 0.7094). While this correlation was less positive for other assays, those, conversely, presented higher true positive values. For most immunoassays, the positive percent agreement of the results was ≥ 95% in sera exhibiting PRNT levels of 1:80 and higher. The assays tested have shown variable correlation to PRNT. Those possessing high positive predictive values serve well as qualitative tests, while others can be utilised as quantitative tests highly predictive of neutralization antibody levels.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , COVID-19/diagnosis , Serologic Tests/methods , Sensitivity and Specificity , Antibodies, Viral , Immunoglobulin G , Neutralization Tests/methods , Antibodies, Neutralizing
11.
J Immunol Methods ; 523: 113585, 2023 12.
Article in English | MEDLINE | ID: mdl-37949349

ABSTRACT

In this study, a proficiency panel was created for evaluation of assay performance and inter- and intra-laboratory assay comparisons, especially the ability to accurately measure negative, low, intermediate, and high levels of HPV type-specific antibodies. Comprised of 80 deidentified samples, this panel is designed for individual labs to evaluate assay performance characteristics on a biennial basis, to promote standardization of methodology and harmonization of data from human papillomavirus (HPV) serology tests in vaccine trials. The proficiency panel was qualified using 2 types of assays (singleplex Enzyme-Linked Immunosorbent Assays [ELISAs] or Multiplex antibody-binding assays and Pseudovirion-based neutralization assays [PBNAs]) in 10 laboratories from 7 countries, monitoring HPV antibody responses for up to 9 HPV types and using 3 different analysis methods. Sensitivity, specificity, and correlations (concordance, accuracy, and precision) were evaluated for each HPV type. In laboratories that tested all 80 samples, results from most (74/80) samples were reported with 100% accuracy across all 9 HPV types. The average sensitivity and specificity for singleplex and multiplex antibody binding assays ranged from 86.7% to 98.3% (sensitivity) and 84.2% to 94.3% (specificity), while the average sensitivity and specificity for the Pseudovirion (PsV)-based neutralization assays (PBNA) ranged from 87.6% to 99.4% (sensitivity) and 52.4% to 94.4% (specificity). This proficiency panel will help with assessing performance characteristics of HPV serology assays used in clinical trial studies and assure the data generated from these assays is harmonized.


Subject(s)
Papillomavirus Infections , Papillomavirus Vaccines , Vaccines , Humans , Neutralization Tests/methods , Antibody Formation , Papillomavirus Infections/diagnosis , Papillomavirus Infections/prevention & control , Antibodies, Viral
12.
J Virol Methods ; 322: 114828, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37778536

ABSTRACT

The conventional method for screening neutralizing antibodies to human enterovirus A71 (EVA71) (microneutralization assay) is time consuming and requires an expert to perform manual evaluation. An automated neutralization assay could shorten the testing time, improve reproducibility, and provide automatic analysis. This study aimed to develop a high-throughput flow cytometric neutralization assay to screen for EVA71 neutralizing antibodies, and to develop quality control materials to ensure accurate testing. The results of this study demonstrate the high potential viability of the proposed flow cytometric method. Compared to the standard method, the flow cytometric method was shown to require a smaller sample volume, provide a much faster turnaround time, provide a rapid result for interpreting the neutralizing antibody level, and allow for possible quantification of results. The observed drawbacks of the proposed method include higher cost per test, longer hands-on time, and lower sensitivity in low titer conditions, which could lead to false negative results. The developed quality control materials were demonstrated to be effective and storable for 1 month. These results pave the way for the optimization and implementation of an automated neutralization assay to screen for neutralizing antibodies not only against EVA71, but also against other viruses in the enterovirus genus.


Subject(s)
Enterovirus A, Human , Enterovirus Infections , Enterovirus , Humans , Antibodies, Neutralizing , Reproducibility of Results , Neutralization Tests/methods , Antibodies, Viral , Antigens, Viral
13.
Emerg Microbes Infect ; 12(2): e2261566, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37727107

ABSTRACT

ABSTRACTThe global outbreak of COVID-19 has caused a severe threat to human health; therefore, simple, high-throughput neutralization assays are desirable for developing vaccines and drugs against COVID-19. In this study, a high-titre SARS-CoV-2 pseudovirus was successfully packaged by truncating the C-terminus of the SARS-CoV-2 spike protein by 21 amino acids and infecting 293 T cells that had been stably transfected with the angiotensin-converting enzyme 2 (ACE2) receptor and furin (named AF cells), to establish a simple, high-throughput, and automated 384-well plate neutralization assay. The method was optimized for cell amount, virus inoculation, incubation time, and detection time. The automated assay showed good sensitivity, accuracy, reproducibility, Z' factor, and a good correlation with the live virus neutralization assay. The high-throughput approach would make it available for the SARS-CoV-2 neutralization test in large-scale clinical trials and seroepidemiological surveys which would aid the accelerated vaccine development and evaluation.


Subject(s)
COVID-19 , Vesicular Stomatitis , Animals , Humans , SARS-CoV-2/genetics , Antibodies, Neutralizing , Reproducibility of Results , Viral Pseudotyping , Antibodies, Viral , Spike Glycoprotein, Coronavirus , Vesicular stomatitis Indiana virus/genetics , Neutralization Tests/methods
14.
J Immunol Methods ; 522: 113568, 2023 11.
Article in English | MEDLINE | ID: mdl-37748728

ABSTRACT

Although it is considered the reference for quantification of neutralizing antibodies, classical method of the plaque reduction neutralization test (PRNT) is labor intensive, requires specific equipment and inputs, besides a long time for its finalization, even in the micro-PRNT version (in 96-well plates). It has a higher sample throughput, however the smaller wells make the reading of plaques more difficult. With an immunoenzymatic revelation step and a semi-automated reading, the µFRN-HRP (micro Focus Reduction Neutralization - Horseradish Peroxidase) is a faster and more efficient test for the quantification of YF neutralizing antibodies. This study aimed to standardize, validate, and compare it with the reference method in 6-well plates (PRNT). Once the execution protocol was standardized, precision, accuracy, selectivity, and robustness were evaluated to validate the µFRN-HRP. In addition, 200 sera of vaccinees were processed by the µFRN-HRP and by the micro-PRNT to compare with the reference test, estimating agreement by Intraclass Correlation Coefficient (ICC). The standardization and validation of the µFRN-HRP was carried out successfully. Weak to moderate agreement was observed between µFRN-HRP and PRNT for titers in reciprocal dilution, while the same comparison between the classical tests resulted in a better ICC. However, titers in milli-international units obtained by µFRN-HRP showed a substantial agreement with PRNT, while the agreement between micro-PRNT and PRNT was inferior. Therefore, µFRN-HRP can be used in the confirmation of natural YF infection and immune response to vaccination, replacing the micro-PRNT, gaining agility, while preserving the specificity of the result.


Subject(s)
Antibodies, Neutralizing , Yellow Fever , Humans , Neutralization Tests/methods , Antibodies, Viral , Reference Standards
15.
Int J Mol Sci ; 24(15)2023 Aug 02.
Article in English | MEDLINE | ID: mdl-37569707

ABSTRACT

COVID-19 is an ongoing, global pandemic caused by the novel, highly infectious SARS-CoV-2 virus. Efforts to mitigate the effects of SARS-CoV-2, such as mass vaccination and development of monoclonal therapeutics, require precise measurements of correlative, functional neutralizing antibodies that block virus infection. The development of rapid, safe, and easy-to-use neutralization assays is essential for faster diagnosis and treatment. Here, we developed a vesicular stomatitis virus (VSV)-based neutralization assay with two readout methods, imaging and flow cytometry, that were capable of quantifying varying degrees of neutralization in patient serum samples. We tested two different spike-pseudoviruses and conducted a time-course assay at multiple multiplicities of infection (MOIs) to optimize the assay workflow. The results of this assay correlate with the results of previously developed serology and surrogate neutralization assays. The two pseudovirus readout methods produced similar values of 50% neutralization titer values. Harvest-free in situ readouts for live-cell imaging and high-throughput analysis results for flow cytometry can provide unique capabilities for fast evaluation of neutralization, which is critical for the mitigation of future pandemics.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , Flow Cytometry , Antibodies, Viral , Neutralization Tests/methods , Antibodies, Neutralizing
16.
J Med Microbiol ; 72(6)2023 Jun.
Article in English | MEDLINE | ID: mdl-37338005

ABSTRACT

Introduction. Diphtheria is a potentially life-threatening infection and remains endemic in many low- and middle-income countries (LMICs). A reliable, low-cost method for serosurveys in LMICs is warranted to estimate the accurate population immunity to control diphtheria.Hypothesis/Gap Statement. The correlation between the ELISA results against diphtheria toxoid and the gold standard diphtheria toxin neutralization test (TNT) values is poor when ELISA values are <0.1 IU ml-1, which results in inaccurate estimates of susceptibility in populations when ELISA is used for measuring antibody levels.Aim. To explore methods to accurately predict population immunity and TNT-derived anti-toxin titres from ELISA anti-toxoid results.Methodology. A total of 96 paired serum and dried blood spot (DBS) samples collected in Vietnam were used for comparison of TNT and ELISA. The diagnostic accuracy of ELISA measurement with reference to TNT was assessed by area under the receiver operating characteristic (ROC) curve (AUC) and other parameters. Optimal ELISA cut-off values corresponding to TNT cut-off values of 0.01 and 0.1 IU ml-1 were identified by ROC analysis. A method based on the multiple imputation approach was also applied to estimate TNT measurements in a dataset that only included ELISA results. These two approaches were then applied to ELISA results previously generated from 510 subjects in a serosurvey in Vietnam.Results. The ELISA results on DBS samples showed a good diagnostic performance compared to TNT. The cut-off values for ELISA measurement corresponding to the TNT cut-off values of 0.01 IU ml-1 were 0.060 IU ml-1 in serum samples, and 0.044 IU ml-1 in DBS samples. When a cut-off value of 0.06 IU ml-1 was applied to the 510 subject serosurvey data, 54 % of the population were considered susceptible (<0.01 IU ml-1). The multiple imputation-based approach estimated that 35 % of the population were susceptible. These proportions were much larger than the susceptible proportion estimated by the original ELISA measurements.Conclusion. Testing a subset of sera by TNT combined with ROC analysis or a multiple imputation approach helps to adjust ELISA thresholds or values to assess population susceptibility more accurately. DBS is an effective low-cost alternative to serum for future serological studies for diphtheria.


Subject(s)
Diphtheria Toxin , Diphtheria , Humans , Diphtheria/diagnosis , Neutralization Tests/methods , Serologic Tests , Enzyme-Linked Immunosorbent Assay/methods
17.
J Virol Methods ; 319: 114769, 2023 09.
Article in English | MEDLINE | ID: mdl-37391076

ABSTRACT

Rabies virus (RABV) causes a fatal encephalitis that can be prevented through timely vaccination. The levels of virus neutralising antibodies against rabies virus induced by vaccination can be measured using the fluorescent antibody virus neutralisation (FAVN) test. Following incubation of live virus with sera, this method involves the fixation of cell monolayers and staining of rabies virus-specific antigen using fluorescein isothiocyanate (FITC) -conjugated antibody to enable visualisation of rabies virus antigen using a fluorescence microscope. To simplify this procedure, a fluorescent recombinant rabies virus was constructed using reverse genetics by inserting the gene for the mCherry fluorescent protein in front of the ribonucleoprotein gene of the SAD B-19 genome and replacing its glycoprotein with that of the Challenge Virus Standard (CVS)-11 RABV strain to ensure antigenic authenticity with the FAVN. This new recombinant virus (termed mCCCG) expressed the mCherry protein to high levels enabling direct observation of infected cells. In vitro growth kinetics of mCCCG were indistinguishable from that of CVS-11. The stability of the recombinant virus was assessed by sequencing several passages of the rescued virus and only minor changes were detected. Comparative assessment of the virus neutralisation test using mCherry producing virus (NTmCV) against the FAVN demonstrated that test results were equivalent to each other; therefore, mCCCG can be used as an alternative to CVS-11 for measuring antibody titres against the rabies virus. The use of NTmCV removes the need for expensive antibody conjugates and significantly reduces assay time. This would be particularly beneficial for RABV serological assessment in resource limited settings. Moreover, the reading of the plates can be automatically using a cell imaging reader.


Subject(s)
Rabies Vaccines , Rabies virus , Rabies , Humans , Rabies virus/genetics , Antibodies, Viral , Neutralization Tests/methods , Antigens, Viral , Antibodies, Neutralizing
18.
Biologicals ; 82: 101681, 2023 May.
Article in English | MEDLINE | ID: mdl-37130447

ABSTRACT

For a long time, a widely used method for tetanus toxoid (Ttd) potency has been the challenge test, in which animals are immunized and then challenged with tetanus toxin in lethal or non-lethal way. In the context of animal welfare, an alternative is desired because the method causes unsustainable distress to animals. We aimed to replace the system for describing test results, in which scores are assigned to symptoms exhibited by challenged animals, with scores assigned to antibody ELISA titers in immunized mouse sera. The potency values and confidence intervals calculated by the absorbance score system were equivalent to those calculated by the symptom score system. We also attempted to utilize the raw ELISA absorbance instead of the assigned absorbance score and obtained similar results. ELISA may serve as an alternative to the lethal challenge for Ttd potency tests, not only in Japan but also in other countries in which mouse challenge tests are employed.


Subject(s)
Tetanus Toxin , Tetanus Toxoid , Mice , Animals , Neutralization Tests/methods , Enzyme-Linked Immunosorbent Assay/methods , Animal Welfare
19.
BMC Infect Dis ; 23(1): 367, 2023 May 31.
Article in English | MEDLINE | ID: mdl-37259032

ABSTRACT

BACKGROUND: As countries move towards or achieve measles elimination status, serosurveillance is an important public health tool. However, a major challenge of serosurveillance is finding a feasible, accurate, cost-effective, and high throughput assay to measure measles antibody concentrations and estimate susceptibility in a population. We conducted a systematic review to assess, characterize, and - to the extent possible - quantify the performance of measles IgG enzyme-linked assays (EIAs) compared to the gold standard, plaque reduction neutralization tests (PRNT). METHODS: We followed the PRISMA statement for a systematic literature search and methods for conducting and reporting systematic reviews and meta-analyses recommended by the Cochrane Screening and Diagnostic Tests Methods Group. We identified studies through PubMed and Embase electronic databases and included serologic studies detecting measles virus IgG antibodies among participants of any age from the same source population that reported an index (any EIA or multiple bead-based assays, MBA) and reference test (PRNT) using sera, whole blood, or plasma. Measures of diagnostic accuracy with 95% confidence intervals (CI) were abstracted for each study result, where reported. RESULTS: We identified 550 unique publications and identified 36 eligible studies for analysis. We classified studies as high, medium, or low quality; results from high quality studies are reported. Because most high quality studies used the Siemens Enzygnost EIA kit, we generate individual and pooled diagnostic accuracy estimates for this assay separately. Median sensitivity of the Enzygnost EIA was 92.1% [IQR = 82.3, 95.7]; median specificity was 96.9 [93.0, 100.0]. Pooled sensitivity and specificity from studies using the Enzygnost kit were 91.6 (95%CI: 80.7,96.6) and 96.0 (95%CI: 90.9,98.3), respectively. The sensitivity of all other EIA kits across high quality studies ranged from 0% to 98.9% with median (IQR) = 90.6 [86.6, 95.2]; specificity ranged from 58.8% to 100.0% with median (IQR) = 100.0 [88.7, 100.0]. CONCLUSIONS: Evidence on the diagnostic accuracy of currently available measles IgG EIAs is variable, insufficient, and may not be fit for purpose for serosurveillance goals. Additional studies evaluating the diagnostic accuracy of measles EIAs, including MBAs, should be conducted among diverse populations and settings (e.g., vaccination status, elimination/endemic status, age groups).


Subject(s)
Measles , Humans , Neutralization Tests/methods , Immunoenzyme Techniques , Measles virus , Sensitivity and Specificity , Antibodies, Viral , Immunoglobulin G
20.
J Virol Methods ; 316: 114716, 2023 06.
Article in English | MEDLINE | ID: mdl-36965633

ABSTRACT

Cervical cancer, the second leading cause of cancer-related deaths among women, is caused by human papillomavirus (HPV), a sexually transmitted virus. Vaccination is an effective preventive measure against viral infections and subsequent development of cervical cancer. Enzyme-linked immunosorbent assay (ELISA) is commonly used to measure specific binding antibody titers and assess the immunogenicity of test vaccines in preclinical models or clinical volunteers. Two methods of deriving titers, the endpoint titer (ET) and the effective dilution producing a median maximal effective fold of dilution (ED50) with a cut-off value, are widely used. For HPV, a pseudovirion-based neutralization assay (PBNA) is used to measure functional antibody titers. The ELISA binding titers and functional PBNA titers were found to be well-correlated for all nine HPV types tested in the vaccine, consistent with previous studies on HPV 16/18. Comparing the PBNA results with the two titration methods, the ED50 method showed higher precision and a closer correlation with PBNA results, both for individual types and pooled data analysis for all nine types. When comparing the titration results of the ET method based on a cut-off value with the ED50 method using all the data points across the dilution series, the ED50 method demonstrated better precision and a stronger correlation with PBNA results.


Subject(s)
Correlation of Data , Enzyme-Linked Immunosorbent Assay , Immunogenicity, Vaccine , Neutralization Tests , Papillomavirus Vaccines , Papillomavirus Vaccines/classification , Papillomavirus Vaccines/immunology , Enzyme-Linked Immunosorbent Assay/methods , Neutralization Tests/methods , Humans , Male , Female , Young Adult , Adult , Antibodies, Neutralizing/immunology , Reproducibility of Results , Immunogenicity, Vaccine/immunology
SELECTION OF CITATIONS
SEARCH DETAIL
...