Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 4.241
Filter
1.
Indian J Dent Res ; 35(2): 245-248, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-39365122

ABSTRACT

ABSTRACT: A 31-year-old male with a history of right zygomaticomaxillary complex (ZMC) fracture presented with aesthetic concerns, continuous tearing, and double vision. The patient had undergone multiple surgeries post accident, resulting in an asymmetrical cheek bulge, persistent diplopia, and epiphora. Investigations revealed abnormal placement of an orbital mesh and damage to the lacrimal sac. A surgical plan was devised to remove the plates, reposition the muscles, secure the floor, correct the epiphora, and provide the desired aesthetics. The surgery involved removal of the mesh and a long plate, refracturing of the zygoma, approximation and securing of the fractured zygoma with plates, and creation of an osteum on the lateral wall of the nose. Post-operatively, the patient's healing was uneventful and he was satisfied with the outcome. This case underscores the importance of a proper surgical technique and patient-centered care in managing complex facial fractures.


Subject(s)
Diplopia , Lacrimal Apparatus Diseases , Orbital Fractures , Humans , Male , Adult , Diplopia/etiology , Orbital Fractures/surgery , Orbital Fractures/complications , Lacrimal Apparatus Diseases/surgery , Lacrimal Apparatus Diseases/etiology , Zygomatic Fractures/surgery , Zygomatic Fractures/complications , Bone Plates , Maxillary Fractures/surgery , Maxillary Fractures/complications , Surgical Mesh
2.
Am J Case Rep ; 25: e944565, 2024 Oct 03.
Article in English | MEDLINE | ID: mdl-39358923

ABSTRACT

BACKGROUND Acquired synkinesis is a well-known phenomenon following oculomotor nerve injury. The abnormal movement appears within the distribution of 1 nerve, or other cranial nerves may be involved. The common misdirection of aberrant regeneration of oculomotor nerve involves the lid, extraocular muscles, or pupil. This report presents a case of aberrant connection between abducens and oculomotor nerve, which is quite rare. CASE REPORT A 21-year-old man with history of left-sided frontal, lateral orbital wall, and zygomatic fracture from head trauma in a motor vehicle accident presented for evaluation. He was comatose for 6 weeks in the intensive care unit. Six months later, he presented to the ophthalmology clinic for an eye examination. He had no history of eye problems prior to this accident. His best corrected visual acuity in the right eye was 20/20 and the left eye had no light perception. The right eye exam was normal, with normal ocular motility. The left eye exam showed small esotropia in primary position with markedly decreased adduction, elevation, and minimal depression, but on attempted abduction, the left eye would adduct instead. There was no globe retraction when left eye abduction was attempted. The abnormal movement seen resulted from third nerve function during sixth nerve stimulation, due to unusual ocular motility with abnormal connection between the sixth and third cranial nerves. CONCLUSIONS The most likely pathophysiologic mechanism here is peripheral neuronal misdirection hypothesis after trauma. Careful and detailed examination of a patient presenting with unusual ocular motility after trauma is very important. The abnormal connection between the sixth and third cranial nerves is quite rare but can occur.


Subject(s)
Synkinesis , Humans , Male , Synkinesis/etiology , Young Adult , Oculomotor Nerve Injuries , Oculomotor Nerve , Abducens Nerve Injury , Oculomotor Nerve Diseases/etiology , Orbital Fractures/complications , Accidents, Traffic , Eye Movements/physiology , Ocular Motility Disorders/etiology , Ocular Motility Disorders/diagnosis
3.
Wiad Lek ; 77(8): 1623-1626, 2024.
Article in English | MEDLINE | ID: mdl-39231335

ABSTRACT

Orbital fractures, constituting 10-25% of facial traumas, result from diverse mechanisms such as traffic accidents and assaults. These fractures present with characteristic symptoms like edema, diplopia, and infraorbital paraesthesia. Timely diagnosis and surgical intervention are paramount to mitigate long-term complications. Recent advancements in materials science and surgical methodologies have ushered in innovative approaches including 3D printing and computer-aided design implants. This article details a case study of successful reconstructive orbital surgery in a patient following a traumatic incident where a car accident caused extensive facial fractures. Leveraging 3D printing technology, a precisely tailored titanium mesh aided in the meticulous restoration of the orbital floor. During surgery, entrapped soft tissues were released, and the zygomatic-maxillary complex was carefully repositioned. Postoperative evaluation revealed promising outcomes, affirming the efficacy of contemporary surgical strategies. This case highlights the evolving role of 3D printing in enhancing the accuracy, cost-effectiveness, and accessibility of orbital reconstruction procedures, demonstrating its potential for broader clinical applications.


Subject(s)
Orbital Fractures , Plastic Surgery Procedures , Printing, Three-Dimensional , Humans , Orbital Fractures/surgery , Plastic Surgery Procedures/methods , Male , Orbit/surgery , Orbit/injuries , Adult , Accidents, Traffic , Surgical Mesh
5.
Eur J Med Res ; 29(1): 427, 2024 Aug 20.
Article in English | MEDLINE | ID: mdl-39164786

ABSTRACT

The aim of this systematic review was to investigate the relationship between fractures of the floor of the orbit (blow outs) and their repercussions on eye movement, based on the available scientific literature. In order to obtain more reliable results, we opted for a methodology that could answer the guiding question of this research. To this end, a systematic review of the literature was carried out, using a rigorous methodological approach. The risk of bias was assessed using version 2 of the Cochrane tool for the risk of bias in randomized trials (RoB 2). This systematic review was carried out according to a systematic review protocol previously registered on the PROSPERO platform. The searches were carried out in the PubMed (National Library of Medicine), Scopus, ScienceDirect, SciELO, Web of Science, Cochrane Library and Embase databases, initially resulting in 553 studies. After removing duplicates, 515 articles remained, 7 were considered eligible, of which 3 were selected for detailed analysis. However, the results of the included studies did not provide conclusive evidence of a direct relationship between orbital floor fractures and eye movement.


Subject(s)
Eye Movements , Orbital Fractures , Humans , Eye Movements/physiology
6.
J Oral Maxillofac Surg ; 82(10): 1275-1284, 2024 Oct.
Article in English | MEDLINE | ID: mdl-39069281

ABSTRACT

BACKGROUND: Utilization of point-of-care 3-dimensional printing (3DP) has decreased length of surgery in facial trauma. Little is known regarding 3DP's impact on length of surgery in orbital fracture. PURPOSE: The purpose of this study was to compare length of surgery between 3DP/preadapted (3DPPA) orbital plates and intraoperative adapted plates (IOAP) for orbital fracture reconstruction. STUDY DESIGN, SETTING, SAMPLE: This was a prospective, non-blinded, randomized clinical study of consecutive subjects with orbital fractures presented to Grady Memorial Hospital in Atlanta, Georgia, between January 2018 and June 2021. Subjects ≥ 18 years, unilateral fracture, no previous orbital surgery, and/or congenital craniofacial anomaly were included. We excluded subjects <18 years and bilateral fractures. PREDICTOR/EXPOSURE/INDEPENDENT VARIABLE: Primary predictor variable was the treatment approach. Randomization software was used, and subjects were randomized to 3DPPA or IOAP groups. MAIN OUTCOME VARIABLE(S): Primary outcome variable was length of surgery in minutes. Secondary outcomes were the time required for plate insertion and fixation in minutes, operating room (OR) charges, and orbital volume (OV) calculation. COVARIATES: Age, sex, race, etiology, laterality, location, dimension, indication for surgery, postoperative enophthalmos, and diplopia. ANALYSES: Univariate and bivariate analyses were calculated. Statistical significance was P < .05. RESULTS: Twenty-five subjects met the inclusion criteria. Mean ages in 3DPPA and conventional IOAP groups were 41.5 (±9) and 38.2 (±10, P = .31), respectively. The mean length of surgery was 32.6 (±13.7) in 3DPPA and 53.3 (±12.8, P < .001) in conventional IOAP. The mean time required for plate insertion and fixation was 15.8n (±14.4) in 3DPPA and 41.4 (±9.4, P < .001) in conventional IOAP. The mean OR charges were $1,072.5 (±524.6) in 3DPPA and $1,757.3 (±422.6, P ≤ 0.001) in conventional IOAP. The mean calculated OV of uninjured and reconstructed orbit for the 3DPPA was 23.5 (±3.2)cm3 and 23 (±3.5, P = .37)cm3, respectively. The mean calculated OV of uninjured and reconstructed orbit for conventional IOAP was 28.6 (±3.6)cm3 and 22.8 (±2.6, P < .001)cm3, respectively. CONCLUSION AND RELEVANCE: Using 3DP to produce a model that enables preoperative plate bending/adaptation reduces the length of surgery, decreases OR charges, and results in predictable OV.


Subject(s)
Bone Plates , Operative Time , Orbital Fractures , Printing, Three-Dimensional , Humans , Orbital Fractures/surgery , Prospective Studies , Female , Male , Adult , Point-of-Care Systems , Middle Aged
7.
BMJ Case Rep ; 17(7)2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38960431

ABSTRACT

A man in his 60s presented with diminution of vision of the left eye with nasal bleeding after accidental fall. On examination his left upper eyelid was lacerated and left temporal sclera was punctured which was repaired under local anaesthesia after which he was discharged by ophthalmologists but continued to complain of pain and left nasal obstruction. A non-contrast CT of paranasal sinuses revealed fracture of medial wall of left orbit, left ethmoid haemosinus and a metallic foreign body (FB) in the septum and anterior face of sphenoid. Diagnostic nasal endoscopy performed to remove the metallic FB showed plastic splinters embedded in the mucosa of nasal cavity which was unexpected. Hence, the FB was removed in two sittings because of diagnostic dilemma.


Subject(s)
Foreign Bodies , Humans , Male , Middle Aged , Foreign Bodies/surgery , Foreign Bodies/diagnostic imaging , Foreign Bodies/complications , Tomography, X-Ray Computed , Nose/injuries , Accidental Falls , Orbital Fractures/surgery , Eye Injuries/complications , Eye Injuries/surgery , Eye Injuries/etiology , Endoscopy/methods , Nasal Obstruction/etiology , Nasal Obstruction/surgery , Orbit/injuries , Orbit/diagnostic imaging , Eye Injuries, Penetrating/surgery , Eye Injuries, Penetrating/diagnostic imaging , Eye Injuries, Penetrating/complications
9.
Int Ophthalmol ; 44(1): 290, 2024 Jun 27.
Article in English | MEDLINE | ID: mdl-38937319

ABSTRACT

PURPOSE: Various materials have been proposed for reconstructing orbital fractures. The materials used must meet certain criteria to ensure their suitability for restoring the structure and function of the organ. These criteria include biocompatibility, ease of application, non-toxicity, hypo-allergenicity, and non-carcinogenicity. In this study, we systematically reviewed the studies regarding the biomaterials in orbital implants and their clinical application. METHODS: A comprehensive search across various databases, including PubMed, Scopus, EMBASE, Cochrane Library, and Web of Science, was conducted until April 10th, 2023. After retrieving the search results and eliminating duplicates, final studies were included after screening through defined criteria. Human and animal studies assessing the clinical application of biomaterials in orbital implants were included. The quality of the case series and controlled intervention studies were evaluated using the NIH tool, and for animal studies, the risk of bias was assessed using SYRCLE's tool. RESULTS: Seventeen studies were included according to defined criteria. These studies aimed to explore the clinical application of biomaterials and examine the associated complications in orbital implants. CONCLUSION: We found that using biomaterials did not result in elevated intraocular pressure (IOP). However, we did observe certain complications, with infection, residual diplopia, and enophthalmos being the most frequently reported issues.


Subject(s)
Biocompatible Materials , Orbital Fractures , Orbital Implants , Animals , Humans , Orbital Fractures/surgery , Plastic Surgery Procedures/methods
10.
Ann Anat ; 255: 152294, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38889825

ABSTRACT

BACKGROUND: Orbital floor fractures result in critical changes in the shape and inferior rectus muscle (IRM) position. Radiological imaging of IRM changes can be used for surgical decision making or prediction of ocular symptoms. Studies with a systematic consideration of the orbital floor defect ratio in this context are missing in the literature. Accordingly, this study on human cadavers aimed to systematically investigate the impact of the orbital floor defect ratio on changes in the IRM and the prediction of posttraumatic enophthalmos. METHODS: Seventy-two orbital floor defects were placed in cadaver specimens using piezosurgical removal. The orbital defect area (ODA), orbital floor area (OFA), position and IRM shape, and enophthalmos were measured using computed tomography (CT) scans. RESULTS: The ODA/OFA ratio correlated significantly (p < 0.001) with the shape (Spearman's rho: 0.558) and position (Spearman's rho: 0.511) of the IRM, and with enophthalmos (Spearman's rho: 0.673). Increases in the ODA/OFA ratio significantly rounded the shape of the IRM (ß: 0.667; p < 0.001) and made a lower position of the IRM more likely (OR: 1.093; p = 0.003). In addition, increases in the ODA/OFA ratio were significantly associated with the development of relevant enophthalmos (OR: 1.159; p = 0.008), adjusted for the defect localization and shape of the IRM. According to receiver operating characteristics analysis (AUC: 0.876; p < 0.001), a threshold of ODA/OFA ratio ≥ 32.691 for prediction of the risk of development of enophthalmos yielded a sensitivity of 0.809 and a specificity of 0.842. CONCLUSION: The ODA/OFA ratio is a relevant parameter in the radiological evaluation of orbital floor fractures, as it increases the risk of relevant enophthalmos, regardless of fracture localization and shape of the IRM. Therefore, changes in the shape and position of the IRM should be considered in surgical treatment planning. A better understanding of the correlates of isolated orbital floor fractures may help to develop diagnostic scores and standardize therapeutic algorithms in the future.


Subject(s)
Cadaver , Enophthalmos , Oculomotor Muscles , Orbit , Orbital Fractures , Tomography, X-Ray Computed , Humans , Enophthalmos/etiology , Enophthalmos/diagnostic imaging , Oculomotor Muscles/diagnostic imaging , Male , Orbital Fractures/diagnostic imaging , Orbital Fractures/complications , Orbital Fractures/surgery , Orbital Fractures/pathology , Female , Aged , Orbit/diagnostic imaging , Orbit/injuries , Middle Aged , Aged, 80 and over
11.
Br J Oral Maxillofac Surg ; 62(6): 542-544, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38834495

ABSTRACT

The transconjunctival approach, first described by Bourqet in 1923, has become a routine procedure for the management of fractures of the orbital floor, medial and lateral walls, and infraorbital rim. It is also used in aesthetic surgery and access surgery. Different approaches of transconjunctival surgery, however, can be complicated by the complex lower lid anatomy. In this publication we revisit the anatomy of the transconjunctival approach, and discuss the surgical steps for preseptal and postseptal dissection. We introduce the concept of interseptal space (potential space), its anatomy first described in 1991.


Subject(s)
Conjunctiva , Orbital Fractures , Humans , Conjunctiva/anatomy & histology , Conjunctiva/surgery , Orbital Fractures/surgery , Eyelids/anatomy & histology , Eyelids/surgery , Orbit/anatomy & histology , Orbit/surgery , Dissection/methods
12.
J Craniofac Surg ; 35(5): 1449-1455, 2024.
Article in English | MEDLINE | ID: mdl-38838361

ABSTRACT

Facial fractures and their historical link to potential blindness have been well-documented, often attributed to optic canal injuries or retinal vascular occlusion. This dire consequence can result from both direct and indirect ocular trauma, including retrobulbar hemorrhage. Traumatic orbital compression can manifest in various forms, such as hematomas, fractured bone fragments, and emphysema, all posing a significant threat to vision, necessitating immediate intervention. In this study, 9 clinical cases of traumatic orbital compression are presented, each characterized by distinct etiologies. The study delves into traumatic orbital compressive syndromes, underscoring the critical imperative of early recognition and treatment to prevent vision loss. Orbital compression, whether from edema, hematoma, or emphysema, collectively culminates in elevated intraorbital pressure and the potential for optic nerve ischemia. Through the presentation of these 9 clinical cases, the article emphasizes the pressing need for timely intervention in addressing orbital compressive syndromes to avert vision loss. Various surgical techniques are elucidated, highlighting the pivotal role of expeditious medical intervention. This article offers invaluable insights into the diagnosis, management, and outcomes of traumatic orbital compressive syndromes.


Subject(s)
Orbital Diseases , Humans , Male , Adult , Female , Middle Aged , Orbital Diseases/etiology , Orbital Diseases/therapy , Orbital Diseases/surgery , Retrobulbar Hemorrhage/etiology , Orbital Fractures/surgery , Orbital Fractures/complications , Hematoma/etiology , Treatment Outcome , Emphysema/etiology , Emphysema/therapy , Edema/etiology , Syndrome , Aged , Tomography, X-Ray Computed , Blindness/etiology , Decompression, Surgical/methods
13.
Int Ophthalmol ; 44(1): 219, 2024 May 07.
Article in English | MEDLINE | ID: mdl-38713333

ABSTRACT

PURPOSE: To determine risk factors for substantial closed-globe injuries in orbital fractures (SCGI) and to develop the best multivariate model for the prediction of SCGI. METHODS: A retrospective study was performed on patients diagnosed with orbital fractures at Farabi Hospital between 2016 and 2022. Patients with a comprehensive ophthalmologic examination and orbital CT scan were included. Predictive signs or imaging findings for SCGI were identified by logistic regression (LR) analysis. Support vector machine (SVM), random forest regression (RFR), and extreme gradient boosting (XGBoost) were also trained using a fivefold cross-validation method. RESULTS: A total of 415 eyes from 403 patients were included. Factors associated with an increased risk of SCGI were reduced uncorrected visual acuity (UCVA), increased difference between UCVA of the traumatic eye from the contralateral eye, older age, male sex, grade of periorbital soft tissue trauma, trauma in the occupational setting, conjunctival hemorrhage, extraocular movement restriction, number of fractured walls, presence of medial wall fracture, size of fracture, intraorbital emphysema and retrobulbar hemorrhage. The area under the curve of the receiver operating characteristic for LR, SVM, RFR, and XGBoost for the prediction of SCGI was 57.2%, 68.8%, 63.7%, and 73.1%, respectively. CONCLUSIONS: Clinical and radiographic findings could be utilized to efficiently predict SCGI. XGBoost outperforms the logistic regression model in the prediction of SCGI and could be incorporated into clinical practice.


Subject(s)
Orbital Fractures , Tomography, X-Ray Computed , Humans , Male , Female , Retrospective Studies , Orbital Fractures/diagnosis , Orbital Fractures/epidemiology , Orbital Fractures/complications , Adult , Middle Aged , Young Adult , Adolescent , Wounds, Nonpenetrating/diagnosis , Wounds, Nonpenetrating/complications , Risk Factors , Visual Acuity , Aged , ROC Curve , Eye Injuries/diagnosis , Eye Injuries/epidemiology , Child
14.
J Craniofac Surg ; 35(5): 1555-1556, 2024.
Article in English | MEDLINE | ID: mdl-38809031

ABSTRACT

Orbital walls are one of the most common sites of midface fractures and account for ~40% of traumatic injuries in this region. These fractures are often associated with changes in the anatomy of the orbital cavity and frequently affect the orbital inferior wall, infraorbital groove and canal, and medial orbital wall, which leads to changes in its pattern and volume as well. Generally, the forces required for brake superior and lateral walls are greater than those required for thin medial and inferior walls. Disruption of any of these structures leads to the expansion of orbital volume that brings to the appearance of enophthalmos, diplopia, and impaired ocular mobility. The gold standard in the treatment of orbital wall fractures is surgical reconstruction, that includes fracture site exposure, freeing tissue prolapsed into the fracture site, and re-approximating the orbital wall support, usually with an orbital implant. It usually could be achieved by the usage of such as transconjunctival, subciliary, and coronal approaches and implementation of graft and reconstructive materials, including bones, cartilage, titanium, and resorbable mesh. Today, the gold standard in orbital floor reconstruction is the application of titanium mesh orbital plates. However, their implementation could be associated with a number of postoperative complications, such as mispositioning and orbital adherence syndrome. Orbital adherence syndrome is a poorly described and understood phenomenon and appears to occur after the use of large-pored titanium mesh for orbital reconstruction. It usually appears as limited eye movement that appears 1 to 2 weeks after reconstructive procedure. Prevention is possible through careful patient selection and the placement of a smooth interface medium in the initial surgery. The aim of the current study is to present the outcomes of orbital reconstruction done by both orbital mesh and customized ​​smooth-surfaced titanium orbital implants.


Subject(s)
Orbital Fractures , Plastic Surgery Procedures , Surgical Mesh , Humans , Orbital Fractures/surgery , Orbital Fractures/diagnostic imaging , Plastic Surgery Procedures/methods , Male , Syndrome , Adult , Female , Postoperative Complications , Titanium , Treatment Outcome , Bone Plates , Orbit/surgery , Orbital Implants , Enophthalmos/surgery , Enophthalmos/etiology
15.
J Craniofac Surg ; 35(5): 1461-1465, 2024.
Article in English | MEDLINE | ID: mdl-38819131

ABSTRACT

OBJECTIVE: This study aimed to investigate the clinical characteristics of patients with complications following inadequate primary orbital fracture repair and to evaluate surgical outcomes of secondary revision orbital reconstruction. METHODS: The authors retrospectively reviewed data from 41 patients who underwent revision orbital reconstruction by a single surgeon following complications from primary orbital fracture repair performed elsewhere. Clinical characteristics, including enophthalmos, exophthalmos, diplopia, ocular motility limitation, epiphora, infraorbital hypoesthesia, infection, eyelid malposition, lagophthalmos, hypoglobus, and compressive optic neuropathy, were assessed. Surgical outcomes of revision surgery were evaluated to determine improvements in clinical deficits and postoperative patient satisfaction. RESULTS: The most common postoperative complications of primary orbital fracture repair were enophthalmos (n=20/41) and diplopia (n=20/41). The mean time between primary and revision surgeries was 67.2 months (range: 1-276 mo). Revision surgery significantly improved enophthalmos, diplopia (Hess area ratio), epiphora (Munk score), periorbital pain, and exophthalmos ( P =0.003, P =0.001, P <0.001, P <0.001, and P =0.007, respectively) compared to the pre-revision state. In addition, 6 patients experienced improved infraorbital hypoesthesia. Among the 41 patients, 23 were very satisfied, 17 were satisfied, and 1 was neutral after revision orbital reconstruction. CONCLUSIONS: Our study highlights the positive impact of revision orbital reconstruction in addressing complications from inadequate primary orbital fracture repair. Surgeons should consider revision surgery to address clinical deficits following prior surgery, especially when anatomic abnormalities are evident in imaging studies, regardless of the time lapse since the initial surgery or concerns about tissue fibrosis and fat atrophy.


Subject(s)
Diplopia , Orbital Fractures , Plastic Surgery Procedures , Postoperative Complications , Reoperation , Humans , Orbital Fractures/surgery , Male , Female , Adult , Retrospective Studies , Middle Aged , Plastic Surgery Procedures/methods , Adolescent , Treatment Outcome , Diplopia/etiology , Diplopia/surgery , Enophthalmos/surgery , Enophthalmos/etiology , Patient Satisfaction , Aged , Child , Exophthalmos/surgery , Exophthalmos/etiology
16.
Article in English | MEDLINE | ID: mdl-38697897

ABSTRACT

OBJECTIVE: Naso-orbito-ethmoidal fractures (NOE) fractures are uncommon but critical injuries. This review aims to investigate the patient factors, procedural factors, and postoperative outcomes associated with the surgical management of NOE fractures. STUDY DESIGN: PubMed and Scopus databases were systematically searched between 1993 and 2023 using the search strategy "(naso-orbito-ethmoidal OR nasoethmoid OR nasoorbitoethmoidal) AND fracture." Articles reporting clinical studies investigating the surgical management of NOE fractures were included. Articles that were duplicates, non-English, or non-full text; reported an unclear age range; reported insufficient data; and/or reported on a sample size less than 10 were excluded. Data on patient factors, procedural factors, and postoperative outcomes were extracted. RESULTS: Of the 412 articles identified, 6 eligible articles (retrospective case series) representing 95 adult cases and 84 pediatric cases were included. The mean ages were 29.0 and 10.2 years, respectively. Most cases were male (65.3%; 73.9%). Motor vehicle accidents were the most common mechanism of injury (79.2% and 50.0%, respectively). Coronal incision was the most common approach. Epiphora (n = 33) and scar problems (n = 21) were the most common complications in adult and pediatric cases, respectively. CONCLUSIONS: Further robust longitudinal studies with a clear description of fracture classification and surgical timing would be helpful. Gaps in knowledge include concomitant injuries, digitally-assisted applications, and risk factors for adverse outcomes.


Subject(s)
Ethmoid Bone , Nasal Bone , Orbital Fractures , Skull Fractures , Humans , Orbital Fractures/surgery , Ethmoid Bone/injuries , Ethmoid Bone/surgery , Skull Fractures/surgery , Nasal Bone/injuries , Nasal Bone/surgery
17.
Oral Maxillofac Surg ; 28(3): 1279-1285, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38691260

ABSTRACT

OBJECTIVE: To analyze the types and causes of complications following orbital fracture reconstruction and enhance clinicians' capacity to manage or prevent such complications. METHODS: We conducted a retrospective case series analysis, retrospectively collecting and analyzing clinical data of patients with orbital fractures who received surgical treatment at the Affiliated Eye Hospital of Nanchang University from May 2012 to May 2022. Descriptive statistics were employed to document common postoperative complications, and we recorded complications persisting after a minimum 6-month follow-up period. RESULTS: Among the 227 patients who underwent orbital fracture surgery, they were followed up for 6 to 36 months, and complications occurred in 15 cases, resulting in an incidence rate of 6.61%. These complications included implant material infections and rejections (4 cases), persistent diplopia (3 cases), intraorbital hematomas (2 cases), epiphora (2 cases), lower eyelid eversion or retraction (2 cases), and skin scars (2 cases). The primary cause of postoperative infection was chronic inflammation in the paranasal sinuses or closed cavities within the fracture area. Postoperative complications in orbital fractures were associated with various factors, including the timing of surgery, surgical approach, repair materials, surgical skills, and auxiliary techniques. CONCLUSION: Standardizing surgical techniques and implementing precise auxiliary technologies may reduce the incidence of complications and enhance the operation's success rate.


Subject(s)
Orbital Fractures , Postoperative Complications , Humans , Orbital Fractures/surgery , Postoperative Complications/etiology , Retrospective Studies , Male , Female , Adult , Middle Aged , Adolescent , Young Adult , Child , Aged , Incidence , Plastic Surgery Procedures/adverse effects , Child, Preschool
18.
J Plast Reconstr Aesthet Surg ; 94: 32-37, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38754270

ABSTRACT

PURPOSE: To present the demographics and clinical characteristics of pure (rim-sparing) orbital roof fractures. METHODS: This retrospective observational study used 10 years of data from a single institution. Patient age, sex, laterality, field of binocular single vision, associated injuries, and radiologic features were analyzed. Orbital roof fractures were categorized into four groups: comminuted/open, hinged, trapdoor, and linear. These were further subdivided into blow-in (-down) and blow-out (-up) fractures. Injury etiology was classified into fall, traffic accidents, sports injuries, assault, work-related, and others. RESULTS: Data documented a low incidence rate of 2.5% (27 patients) in 1074 patients. Most patients were male (81%). The most common cause of injury was fall (48%), followed by traffic accidents (22%). Comminuted/open fractures constituted the bulk of fracture types (54%), followed by hinged, and linear fractures. Blow-in and blow-out fractures had an incidence rate of 50% each. Concomitant fractures of the medial and inferior orbital walls were predominant. Low surgical intervention was noted owing to acceptable field of binocular single vision outcomes, and the field of binocular single vision included the primary position of gaze in 88% of patients. CONCLUSION: Pure orbital roof fractures occurred in 2.5% of patients with pure orbital fractures. Patients were predominantly male with trauma caused by high energy forces, which regularly caused comminution of the roof and fractures of the medial and inferior orbital walls. Most patients were managed conservatively.


Subject(s)
Orbital Fractures , Humans , Orbital Fractures/epidemiology , Orbital Fractures/surgery , Orbital Fractures/complications , Male , Retrospective Studies , Female , Adult , Middle Aged , Aged , Adolescent , Young Adult , Incidence , Accidents, Traffic/statistics & numerical data , Accidental Falls/statistics & numerical data , Child
19.
BMC Ophthalmol ; 24(1): 146, 2024 Apr 03.
Article in English | MEDLINE | ID: mdl-38566099

ABSTRACT

BACKGROUND: Trauma-induced orbital blowout fracture (OBF) with eyeball displacement into the maxillary sinus is rare. CASE PRESENTATION: We present the case of a 14-year-old with a closed head injury, OBF, and displacement of the eyeball into the maxillary sinus following a car accident. A prompt transconjunctival access surgery was performed for eyeball repositioning and orbital reconstruction in a single session, mitigating anaesthesia-related risks associated with multiple surgeries. At the 12-month follow-up, his visual acuity was 20/200. Despite limited eye movement and optic nerve atrophy, overall satisfaction with the ocular appearance was achieved. CONCLUSIONS: This report offers novel insights into the mechanisms of OBF occurrence and the development of postoperative complications.


Subject(s)
Head Injuries, Closed , Ocular Motility Disorders , Orbital Fractures , Male , Humans , Adolescent , Maxillary Sinus , Eye , Orbital Fractures/complications , Orbital Fractures/diagnosis , Orbital Fractures/surgery , Head Injuries, Closed/complications
20.
Article in English | MEDLINE | ID: mdl-38582707

ABSTRACT

PURPOSE: This article outlines the management of a rare and severe nasoorbital injury resulting from a chainsaw kickback accident in a 60-year-old male. A meta-narrative review of English, French, and German literature indexed in PubMed, Embase, and the Cochrane Library up to January 8, 2024, accompanies the case report. METHODS: This was a case report combined with a comprehensive review based on the 2011 Oxford Centre for Evidence-Based Medicine's highest and most recent level of evidence (LoE) and highest recommendation grade (RG). Rigorous selection criteria were applied. RESULTS: The patient had an open nasal fracture, complex lacerations, and avulsion of the left eyelid, lateral orbital wall and lateral rectus muscle. Staged surgical interventions comprised repositioning and fixation of the fractured nose, buccal mucosal grafting for nasal mucosa and conjunctiva repair, titanium mesh and polydioxanone sheet for lateral orbital wall reconstruction, and subsequent muscle and eyelid repair. The second intervention 3 months postsurgery addressed lateral ectropion, nasal dorsal hump, and nasolacrimal system issues. Despite the rarity of such injuries, evidence-based discussions were conducted. CONCLUSIONS: Complex nasoorbital trauma resulting from chainsaw kickback necessitates a meticulous, staged surgical approach. The inside-out technique proved effective in addressing various challenges. This article concludes with evidence-based recommendations, highlighting the importance of adapting established principles to unique nature of these injuries.


Subject(s)
Plastic Surgery Procedures , Humans , Male , Middle Aged , Plastic Surgery Procedures/methods , Eyelids/injuries , Eyelids/surgery , Orbital Fractures/surgery
SELECTION OF CITATIONS
SEARCH DETAIL