Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 12.867
1.
Int J Implant Dent ; 10(1): 29, 2024 Jun 05.
Article En | MEDLINE | ID: mdl-38839621

PURPOSE: This study evaluated the implant stability, volumetric changes, and patient-reported outcome measures (PROMs) of hydroxyapatite (HA) nano-coated sandblasted/acid-etched (SLA) implants compared to uncoated SLA implants. METHODS: Forty patients were recruited and randomly allocated to HA nano-coated SLA group (test, n = 20) and uncoated SLA group (control, n = 20) using single-blinded/block randomization. Implants were immediately placed in maxillary posterior region using a digital surgical guide. Insertion torque and implant stability quotient (ISQ) were measured at implant surgery and 1, 2, 3, and 4 months postoperatively. Intraoral scans, PROMs and soft tissue inflammation data were collected, and multivariable linear regression analysis of ISQ was performed. RESULTS: In total, 48 implants (test; n = 24, control; n = 24) in 37 patients (test; n = 19, control; n = 18) were analyzed. Despite no significant between-group difference at surgery, the test group showed higher ISQ values than the control group at 2 (76.53 ± 4.17 vs. 71.32 ± 4.79, p < 0.01), 3 (77.45 ± 4.41 vs. 73.85 ± 4.69, p < 0.05), and 4 months (79.08 ± 2.96 vs. 73.43 ± 3.52, p < 0.0001) postoperatively. There were no significant differences in linear and volumetric changes, PROMs, and soft tissue inflammation analysis between two groups. The ISQ at implant surgery was influenced by age and diabetes mellitus (DM) at the implant level and DM and predicted total bone-to-implant contact area at the patient level. CONCLUSION: HA nano-coated SLA implants promoted favorable immediate implants stability during early osseointegration phase compared to uncoated SLA implants, but displayed similar dimensional changes, PROMs, and soft tissue inflammation outcomes. TRIAL REGISTRATION: Clinical Research Information Service (CRIS), KCT0006364. Registered 21 July 2021, https://cris.nih.go.kr/cris/search/detailSearch.do?seq=24221&search_page=L .


Durapatite , Humans , Male , Female , Middle Aged , Single-Blind Method , Dental Implants , Immediate Dental Implant Loading/methods , Adult , Coated Materials, Biocompatible/chemistry , Acid Etching, Dental , Aged , Patient Reported Outcome Measures , Osseointegration , Surface Properties
2.
Int J Nanomedicine ; 19: 5011-5020, 2024.
Article En | MEDLINE | ID: mdl-38832337

Purpose: Atomic layer deposition (ALD) is a method that can deposit zirconia uniformly on an atomic basis. The effect of deposited zirconia on titanium implants using ALD was evaluated in vivo. Methods: Machined titanium implants (MTIs) were used as the Control. MTIs treated by sandblasting with large grit and acid etching (SA) and MTIs deposited with zirconia using ALD are referred to as Groups S and Z, respectively. Twelve implants were prepared for each group. Six rabbits were used as experimental animals. To evaluate the osteogenesis and osteocyte aspects around the implants, radiological and histological analyses were performed. The bone-to-implant contact (BIC) ratio was measured and statistically analyzed to evaluate the osseointegration capabilities. Results: In the micro-CT analysis, more radiopaque bone tissues were observed around the implants in Groups S and Z. Histological observation found that Groups S and Z had more and denser mature bone tissues around the implants in the cortical bone area. Many new and mature bone tissues were also observed in the medullary cavity area. For the BIC ratio, Groups S and Z were significantly higher than the Control in the cortical bone area (P < 0.017), but there was no significant difference between Groups S and Z. Conclusion: MTIs deposited with zirconia using ALD (Group Z) radiologically and histologically showed more mature bone formation and activated osteocytes compared with MTIs (Control). Group Z also had a significantly higher BIC ratio than the Control. Within the limitations of this study, depositing zirconia on the surface of MTIs using ALD can improve osseointegration in vivo.


Osseointegration , Titanium , Zirconium , Animals , Zirconium/chemistry , Zirconium/pharmacology , Rabbits , Titanium/chemistry , Titanium/pharmacology , Osseointegration/drug effects , Surface Properties , X-Ray Microtomography , Coated Materials, Biocompatible/chemistry , Coated Materials, Biocompatible/pharmacology , Bone-Implant Interface , Osteogenesis/drug effects , Dental Implants , Prostheses and Implants
3.
Int J Implant Dent ; 10(1): 24, 2024 May 09.
Article En | MEDLINE | ID: mdl-38722448

PURPOSE: The objective of the present study was to ascertain the effect of immediate occlusal loading after implant placement on osseointegration and the micro/nanostructure of the surrounding bone. METHODS: After extraction of a rat maxillary right second molar, an implant was placed immediately with initial fixation (2 N< ). The implants were placed to avoid occlusal loading due to mastication, and in the loaded group, a superstructure was fabricated and subjected to occlusal loading. Bone morphometry, collagen fiber anisotropy, and biological apatite (BAp) crystallite alignment were quantitatively evaluated in both groups after extraction and fixation of the jaw bone at Days 7 and 21 after surgery. RESULTS: Osseointegration was observed in both groups. Bone morphometry showed significant differences in bone volume, trabecular number, trabecular thickness and bone mineral density (BMD) at Days 21 postoperatively (P < 0.05). A significant difference was also found in the trabecular separation at Days 7 postoperatively (P < 0.05). In the evaluation of collagen fiber anisotropy, collagen fiber bundles running differently from the existing bone were observed in both groups. In terms of BAp crystallite alignment, a specific structure was observed in the reconstructed new bone after implantation, and preferential orientation of BAp crystallite alignment was observed in the longitudinal direction of the implants in the Day 21 postoperative loaded group. CONCLUSION: When sufficient initial fixation is achieved at the time of dental implant placement, then the applied masticatory load may contribute to rapidly achieving not only bone volume, but also adequate bone quality after implant placement.


Immediate Dental Implant Loading , Osseointegration , Animals , Rats , Osseointegration/drug effects , Male , Bone Density/physiology , Dental Implants , Rats, Wistar , Maxilla/surgery , Collagen/metabolism , X-Ray Microtomography
4.
Wiad Lek ; 77(3): 462-471, 2024.
Article En | MEDLINE | ID: mdl-38691788

OBJECTIVE: Aim: To study the specifics of the impact of immediate intraoperative loading with a splinting component on supporting tissues during a one-stage implantation protocol. PATIENTS AND METHODS: Materials and Methods: In the course of the study, orthopedic treatment was carried out for 55 patients aged 29 to 60 years. The following were performed: cone-beam computed tomography, software planning and intraoral scanning with an optical scanner, one-stage implantation protocol, assessment of implant stability with the Osstell ISQ device, microcirculation study in the peri-implant area using laser Doppler flowmetry (LDF). RESULTS: Results: It was established that around loaded implants there is an increase in blood flow and vasomotor activity of the microcirculatory channel of the supporting tissues, an increase in the volume of bone tissue and an increase in torque, which is the optimal forecast for the acceleration of the pace of osseointegration. CONCLUSION: Conclusions: The use of a splinting component during immediate intraoperative functional masticatory load accelerates the dynamics of bone tissue remodeling processes around the implant, which is an optimal prediction of osseointegration rates in various dental implantation protocols and is consistent with high values of the implant stability coefficient.


Immediate Dental Implant Loading , Humans , Middle Aged , Adult , Male , Female , Splints , Osseointegration , Dental Implants , Dental Implantation, Endosseous/methods , Cone-Beam Computed Tomography
5.
J Orthop Surg Res ; 19(1): 273, 2024 May 02.
Article En | MEDLINE | ID: mdl-38698477

BACKGROUND: Talar malignant tumor is extremely rare. Currently, there are several alternative management options for talus malignant tumor including below-knee amputation, tibio-calcaneal arthrodesis, and homogenous bone transplant while their shortcomings limited the clinical application. Three-dimensional (3D) printed total talus prosthesis in talus lesion was reported as a useful method to reconstruct talus, however, most researches are case reports and its clinical effect remains unclear. Therefore, the current study was to explore the application of 3D printed custom-made modular prosthesis in talus malignant tumor. METHODS: We retrospectively analyzed the patients who received the 3D printed custom-made modular prosthesis treatment due to talus malignant tumor in our hospital from February 2016 to December 2021. The patient's clinical data such as oncology outcome, operation time, and volume of blood loss were recorded. The limb function was evaluated with the Musculoskeletal Tumor Society 93 (MSTS-93) score, The American Orthopedic Foot and Ankle Society (AOFAS) score; the ankle joint ranges of motion as well as the leg length discrepancy were evaluated. Plain radiography and Tomosynthesis-Shimadzu Metal Artefact Reduction Technology (T-SMART) were used to evaluate the position of prosthesis and the osseointegration. Postoperative complications were recorded. RESULTS: The average patients' age and the follow-up period were respectively 31.5 ± 13.1 years; and 54.8 months (range 26-72). The medium operation time was 2.4 ± 0.5 h; the intraoperative blood loss was 131.7 ± 121.4 ml. The mean MSTS-93 and AOFAS score was 26.8 and 88.5 respectively. The average plantar flexion, dorsiflexion, varus, and valgus were 32.5, 9.2, 10.8, and 5.8 degree respectively. One patient had delayed postoperative wound healing. There was no leg length discrepancy observed in any patient and good osseointegration was observed on the interface between the bone and talus prosthesis in all subjects. CONCLUSION: The modular structure of the prosthesis developed in this study seems to be convenient for prosthesis implantation and screws distribution. And the combination of solid and porous structure improves the initial stability and promotes bone integration. Therefore, 3D printed custom-made modular talus prosthesis could be an alternative option for talus reconstruction in talus malignant tumor patients.


Bone Neoplasms , Printing, Three-Dimensional , Prosthesis Design , Talus , Humans , Talus/surgery , Talus/diagnostic imaging , Male , Adult , Female , Bone Neoplasms/surgery , Bone Neoplasms/diagnostic imaging , Retrospective Studies , Middle Aged , Young Adult , Prosthesis Implantation/methods , Prosthesis Implantation/instrumentation , Adolescent , Ankle Joint/surgery , Ankle Joint/diagnostic imaging , Osseointegration , Treatment Outcome , Range of Motion, Articular , Prostheses and Implants
6.
Int J Nanomedicine ; 19: 4515-4531, 2024.
Article En | MEDLINE | ID: mdl-38803996

Introduction: There is an ongoing need for improved healing response and expedited osseointegration on the Ti implants in acetabular fracture sites. To achieve adequate bonding and mechanical stability between the implant surface and the acetabular fracture, a new coating technology must be developed to promote bone integration and prevent bacterial growth. Methods: A cylindrical Ti substrate mounted on a rotating specimen holder was used to implant Ca2+, P2+, and Sr2+ ions at energies of 100 KeV, 75 KeV and 180 KeV, respectively, using a low-energy accelerator to synthesize strontium-substituted hydroxyapatite at varying conditions. Ag2+ ions of energy 100 KeV were subsequently implanted on the as-formed surface at the near-surface region to provide anti-bacterial properties to the as-formed specimen. Results: The properties of the as-formed ion-implanted specimen were compared with the SrHA-Ag synthesized specimens by cathodic deposition and low-temperature high-speed collision technique. The adhesion strength of the ion-implanted specimen was 43 ± 2.3 MPa, which is well above the ASTM standard for Ca-P coating on Ti. Live/dead cell analysis showed higher osteoblast activity on the ion-implanted specimen than the other two. Ag in the SrHA implanted Ti by ion implantation process showed superior antibacterial activity. Discussion: In the ion implantation technique, nano-topography patterned surfaces are not concealed after implantation, and their efficacy in interacting with the osteoblasts is retained. Although all three studies examined the antibacterial effects of Ag2+ ions and the ability to promote bone tissue formation by MC3T3-E1 cells on SrHA-Ag/Ti surfaces, ion implantation techniques demonstrated superior ability. The synthesized specimen can be used as an effective implant in acetabular fracture sites based on their mechanical and biological properties.


Acetabulum , Anti-Bacterial Agents , Silver , Strontium , Titanium , Titanium/chemistry , Titanium/pharmacology , Silver/chemistry , Silver/pharmacology , Strontium/chemistry , Strontium/pharmacology , Anti-Bacterial Agents/pharmacology , Anti-Bacterial Agents/chemistry , Acetabulum/injuries , Animals , Coated Materials, Biocompatible/chemistry , Coated Materials, Biocompatible/pharmacology , Osseointegration/drug effects , Mice , Surface Properties , Fractures, Bone/therapy , Durapatite/chemistry , Durapatite/pharmacology , Osteoblasts/drug effects , Hydroxyapatites/chemistry , Hydroxyapatites/pharmacology , Prostheses and Implants , Ions/chemistry , Ions/pharmacology , Humans , Cell Line
7.
Bull Exp Biol Med ; 176(5): 620-625, 2024 Mar.
Article En | MEDLINE | ID: mdl-38733480

We studied the interaction of human buccal mesenchymal stem cells (MSCs) and osteoblasts differentiated from them with the surface of titanium samples. MSCs were isolated by enzymatic method from buccal fat pads. The obtained cell culture was presented by MSCs, which was confirmed by flow cytometry and differentiation into adipocytes and osteoblasts. Culturing of buccal MSCs on titanium samples was accompanied by an increase in the number of cells for 15 days and the formation of a developed network of F-actin fibers in the cells. The viability of buccal MSCs decreased by 8 days, but was restored by 15 days. Culturing of osteoblasts obtained as a result of buccal MSC differentiation on the surface of titanium samples was accompanied by a decrease in their viability and proliferation. Thus, MSCs from buccal fat pads can be used to coat implants to improve osseointegration during bone reconstruction in craniofacial surgery and dentistry. To improve the integration of osteoblasts, modification of the surface of titanium samples is required.


Cell Differentiation , Mesenchymal Stem Cells , Osseointegration , Osteoblasts , Titanium , Titanium/chemistry , Mesenchymal Stem Cells/cytology , Mesenchymal Stem Cells/physiology , Humans , Osseointegration/physiology , Osteoblasts/cytology , Osteoblasts/physiology , Cells, Cultured , Cell Proliferation , Dental Implants , Cell Survival , Adipocytes/cytology , Adipocytes/physiology , Mouth Mucosa/cytology , Osteogenesis/physiology
8.
Int J Mol Sci ; 25(10)2024 May 13.
Article En | MEDLINE | ID: mdl-38791362

In the field of biomaterials for prosthetic reconstructive surgery, there is the lack of advanced innovative methods to investigate the potentialities of smart biomaterials before in vivo tests. Despite the complex osteointegration process being difficult to recreate in vitro, this study proposes an advanced in vitro tissue culture model of osteointegration using human bone. Cubic samples of trabecular bone were harvested, as waste material, from hip arthroplasty; inner cylindrical defects were created and assigned to the following groups: (1) empty defects (CTRneg); (2) defects implanted with a cytotoxic copper pin (CTRpos); (3) defects implanted with standard titanium pins (Ti). Tissues were dynamically cultured in mini rotating bioreactors and assessed weekly for viability and sterility. After 8 weeks, immunoenzymatic, microtomographic, histological, and histomorphometric analyses were performed. The model was able to simulate the effects of implantation of the materials, showing a drop in viability in CTR+, while Ti appears to have a trophic effect on bone. MicroCT and a histological analysis supported the results, with signs of matrix and bone deposition at the Ti implant site. Data suggest the reliability of the tested model in recreating the osteointegration process in vitro with the aim of reducing and refining in vivo preclinical models.


Osseointegration , Tissue Culture Techniques , Titanium , Humans , Tissue Culture Techniques/methods , X-Ray Microtomography , Bone and Bones/cytology , Biocompatible Materials , Prostheses and Implants , Cancellous Bone/cytology
9.
J Rehabil Med ; 56: jrm34141, 2024 May 21.
Article En | MEDLINE | ID: mdl-38770700

OBJECTIVE: To describe and evaluate the combination of osseointegration and nerve transfers in 3 transhumeral amputees. DESIGN: Case series. PATIENTS: Three male patients with a unilateral traumatic transhumeral amputation. METHODS: Patients received a combination of osseointegration and targeted muscle reinnervation surgery. Rehabilitation included graded weight training, range of motion exercises, biofeedback, table-top prosthesis training, and controlling the actual device. The impairment in daily life, health-related quality of life, and pain before and after the intervention was evaluated in these patients. Their shoulder range of motion, prosthesis embodiment, and function were documented at a 2- to 5-year follow-up. RESULTS: All 3 patients attended rehabilitation and used their myoelectric prosthesis on a daily basis. Two patients had full shoulder range of motion with the prosthesis, while the other patient had 55° of abduction and 45° of anteversion. They became more independent in their daily life activities after the intervention and incorporated their prosthesis into their body scheme to a high extent. CONCLUSION: These results indicate that patients can benefit from the combined procedure. However, the patients' perspective, risks of the surgical procedures, and the relatively long rehabilitation procedure need to be incorporated in the decision-making.


Amputees , Artificial Limbs , Nerve Transfer , Osseointegration , Range of Motion, Articular , Humans , Male , Osseointegration/physiology , Adult , Amputees/rehabilitation , Nerve Transfer/methods , Range of Motion, Articular/physiology , Bionics , Treatment Outcome , Muscle, Skeletal , Middle Aged , Humerus/surgery , Quality of Life , Amputation, Traumatic/rehabilitation , Amputation, Traumatic/surgery , Activities of Daily Living
10.
Comput Biol Med ; 175: 108551, 2024 Jun.
Article En | MEDLINE | ID: mdl-38703546

The long-term performance of porous coated tibial implants for total ankle replacement (TAR) primarily depends on the extent of bone ingrowth at the bone-implant interface. Although attempts were made for primary fixation for immediate post-operative stability, no investigation was conducted on secondary fixation. The aim of this study is to assess bone ingrowth around the porous beaded coated tibial implant for TAR using a mechanoregulatory algorithm. A realistic macroscale finite element (FE) model of the implanted tibia was developed based on computer tomography (CT) data to assess implant-bone micromotions and coupled with microscale FE models of the implant-bone interface to predict bone ingrowth around tibial implant for TAR. The macroscale FE model was subjected to three near physiological loading conditions to evaluate the site-specific implant-bone micromotion, which were then incorporated into the corresponding microscale model to mimic the near physiological loading conditions. Results of the study demonstrated that the implant experienced tangential micromotion ranged from 0 to 71 µm with a mean of 3.871 µm. Tissue differentiation results revealed that bone ingrowth across the implant ranged from 44 to 96 %, with a mean of around 70 %. The average Young's modulus of the inter-bead tissue layer varied from 1444 to 4180 MPa around the different regions of the implant. The analysis postulates that when peak micromotion touches 30 µm around different regions of the implant, it leads to pronounced fibrous tissues on the implant surface. The highest amount of bone ingrowth was observed in the central regions, and poor bone ingrowth was seen in the anterior parts of the implant, which indicate improper osseointegration around this region. This macro-micro mechanical FE framework can be extended to improve the implant design to enhance the bone ingrowth and in future to develop porous lattice-structured implants to predict and enhance osseointegration around the implant.


Algorithms , Arthroplasty, Replacement, Ankle , Finite Element Analysis , Tibia , Humans , Tibia/surgery , Tibia/diagnostic imaging , Arthroplasty, Replacement, Ankle/instrumentation , Tomography, X-Ray Computed , Models, Biological , Osseointegration/physiology , Bone-Implant Interface/diagnostic imaging , Joint Prosthesis
11.
Biomater Adv ; 161: 213899, 2024 Jul.
Article En | MEDLINE | ID: mdl-38772133

Large bone defects, particularly those exceeding the critical size, present a clinical challenge due to the limited regenerative capacity of bone tissue. Traditional treatments like autografts and allografts are constrained by donor availability, immune rejection, and mechanical performance. This study aimed to develop an effective solution by designing gradient gyroid scaffolds with titania (TiO2) surface modification for the repair of large segmental bone defects. The scaffolds were engineered to balance mechanical strength with the necessary internal space to promote new bone formation and nutrient exchange. A gradient design of the scaffold was optimized through Finite Element Analysis (FEA) and Computational Fluid Dynamics (CFD) simulations to enhance fluid flow and cell adhesion. In vivo studies in rabbits demonstrated that the G@TiO2 scaffold, featuring a gradient structure and TiO2 surface modification, exhibited superior healing capabilities compared to the homogeneous structure and TiO2 surface modification (H@TiO2) and gradient structure (G) scaffolds. At 12 weeks post-operation, in a bone defect representing nearly 30 % of the total length of the radius, the implantation of the G@TiO2 scaffold achieved a 27 % bone volume to tissue volume (BV/TV) ratio, demonstrating excellent osseointegration. The TiO2 surface modification provided photothermal antibacterial effects, enhancing the scaffold's biocompatibility and potential for infection prevention. These findings suggest that the gradient gyroid scaffold with TiO2 surface modification is a promising candidate for treating large segmental bone defects, offering a combination of mechanical strength, bioactivity, and infection resistance.


Alloys , Surface Properties , Tissue Scaffolds , Titanium , Titanium/chemistry , Animals , Rabbits , Tissue Scaffolds/chemistry , Alloys/chemistry , Bone Regeneration/drug effects , Osseointegration/drug effects , Bone and Bones , Tissue Engineering/methods , Finite Element Analysis , Biocompatible Materials/chemistry , Biocompatible Materials/pharmacology
12.
Int J Periodontics Restorative Dent ; 44(3): 321-329, 2024 05 24.
Article En | MEDLINE | ID: mdl-38787707

This pilot case series histologically and histometrically investigated the influence of implant surface hydrophilicity on early osseointegration and peri-implant bone formation around simultaneously grafted immediate implants. Hydrophilic test (SLAactive) or hydrophobic control (SLA) implants were immediately placed in maxillary molar extraction sites and simultaneously grafted with mineralized cancellous bone allograft (MCBA). Core biopsy samples were obtained at 3 weeks postplacement and histometrically compared for bone-to-implant contact, quantity of graft material, new bone formation, tissue reaction, and inflammatory scores. Test implants showed a more pronounced implant-bone apposition, peri-implant bone formation, and bone aggregate than control implants. Trabecular bone formation and maturation were also qualitatively advanced around test implants. These results indicate that the combination of implant surface and bone graft may affect periimplant bone formation.


Dental Implants , Hydrophobic and Hydrophilic Interactions , Osseointegration , Osteogenesis , Surface Properties , Titanium , Humans , Female , Male , Osteogenesis/physiology , Pilot Projects , Middle Aged , Adult , Bone Transplantation/methods , Immediate Dental Implant Loading/methods , Maxilla/surgery , Maxilla/pathology , Dental Implantation, Endosseous/methods
13.
Biomed Mater ; 19(4)2024 May 22.
Article En | MEDLINE | ID: mdl-38740037

The purpose of this study was to construct a rutin-controlled release system on the surface of Ti substrates and investigate its effects on osteogenesis and osseointegration on the surface of implants. The base layer, polyethylenimine (PEI), was immobilised on a titanium substrate. Then, hyaluronic acid (HA)/chitosan (CS)-rutin (RT) multilayer films were assembled on the PEI using layer-by-layer (LBL) assembly technology. We used scanning electron microscopy (SEM), Fourier transform infrared (FTIR) spectroscopy and contact angle measurements to examine all Ti samples. The drug release test of rutin was also carried out to detect the slow-release performance. The osteogenic abilities of the samples were evaluated by experiments on an osteoporosis rat model and MC3T3-E1 cells. The results (SEM, FTIR and contact angle measurements) all confirmed that the PEI substrate layer and HA/CS-RT multilayer film were effectively immobilised on titanium. The drug release test revealed that a rutin controlled release mechanism had been successfully established. Furthermore, thein vitrodata revealed that osteoblasts on the coated titanium matrix had greater adhesion, proliferation, and differentiation capacity than the osteoblasts on the pure titanium surface. When MC3T3-E1 cells were exposed to H2O2-induced oxidative stressin vitro, cell-based tests revealed great tolerance and increased osteogenic potential on HA/CS-RT substrates. We also found that the HA/CS-RT coating significantly increased the new bone mass around the implant. The LBL-deposited HA/CS-RT multilayer coating on the titanium base surface established an excellent rutin-controlled release system, which significantly improved osseointegration and promoted osteogenesis under oxidative stress conditions, suggesting a new implant therapy strategy for patients with osteoporosis.


Coated Materials, Biocompatible , Hyaluronic Acid , Osseointegration , Osteoblasts , Osteogenesis , Osteoporosis , Prostheses and Implants , Rutin , Surface Properties , Titanium , Animals , Titanium/chemistry , Rutin/chemistry , Rutin/pharmacology , Osteogenesis/drug effects , Rats , Osteoporosis/drug therapy , Mice , Osteoblasts/drug effects , Osteoblasts/cytology , Osteoblasts/metabolism , Osseointegration/drug effects , Hyaluronic Acid/chemistry , Coated Materials, Biocompatible/chemistry , Coated Materials, Biocompatible/pharmacology , Oxidation-Reduction , Chitosan/chemistry , Female , Rats, Sprague-Dawley , Cell Adhesion/drug effects , Spectroscopy, Fourier Transform Infrared , Cell Differentiation/drug effects , Microscopy, Electron, Scanning , Cell Proliferation/drug effects , Polyethyleneimine/chemistry , 3T3 Cells , Oxidative Stress/drug effects , Layer-by-Layer Nanoparticles
14.
Acta Biochim Pol ; 71: 12433, 2024.
Article En | MEDLINE | ID: mdl-38721304

The study aimed to determine the osteointegration markers after dental implantation and evaluate their predictive value. The study was performed on 60 practically healthy persons who needed teeth rehabilitation using dental implants. The conical-shaped implants (CI) and hexagonal implants (HI) were used. The content of Osteopontin (OPN), Osteocalcin (OC), Alkaline Phosphatase (ALP), Osteoprotegerin (OPG), and nitric oxide (NO) was determined in patients' gingival crevicular fluid (GCF) and peri-implant sulcular fluid (PISF), collected 1, 3, and 6 months after implantation. During the 3-6 months of observation level of OPN increased in patients with CIs (<50 years > 50 years) and HIs (<50 years) (CI: <50 years F = 36.457, p < 0.001; >50 years F = 30.104, p < 0.001; HI < 50 years F = 2.246, p < 0.001), ALP increased in patients with CIs (<50 years: F = 19.58, p < 0.001; >50 years: F = 12.01; p = 0.001) and HIs (<50 years) (F = 18.51, p < 0.001), OC increased in patients <50 years (CI: F = 33.72, p < 0.001; HI: F = 55.57, p < 0.001), but in patients >50 years - on the 3 days month (CI: F = 18.82, p < 0.001; HI: F = 26.26, p < 0.001), but sharply decreased at the end of sixth month. OPG increased during 1-3 months of the observation in patients <50 years (CI: F = 4.63, p = 0.037; HI: F = 2.8927, p = 0.046), but at the end of the sixth month returned to the initial level; NO content in PISF increased in patients with CI (>50 years) during 1-6 months of the observation (F = 27.657, p < 0.001). During the post-implantation period, age-related differences in osteointegration were observed. Patients <50 years old had relatively high levels of OPN, ALP, OC, and OPG in PISF, resulting in less alveolar bone destruction around dental implants and more intensive osteointegration. These indicators may be used as biological markers for monitoring implant healing. The process of osseointegration was more intense in CIs due to their comparatively high mechanical loading.


Alkaline Phosphatase , Biomarkers , Dental Implants , Gingival Crevicular Fluid , Osseointegration , Osteocalcin , Osteopontin , Osteoprotegerin , Humans , Middle Aged , Biomarkers/metabolism , Female , Male , Osteoprotegerin/metabolism , Gingival Crevicular Fluid/metabolism , Alkaline Phosphatase/metabolism , Osteocalcin/metabolism , Adult , Osteopontin/metabolism , Prognosis , Nitric Oxide/metabolism , Dental Implantation/methods , Time Factors
15.
Iran Biomed J ; 28(2&3): 82-9, 2024 05 01.
Article En | MEDLINE | ID: mdl-38770885

Background: Osteogenic, antioxidant and anti-inflammatory effects of Whey protein and M. oleifera gel prompted us to evaluate their role alone or in combination on osseointegration in rabbits. Methods: In this study, 24 titanium implants were inserted in the femurs of six rabbits. One implant was placed without treatment, and another one was coated with a mixture of whey protein and M. oleifera gel for each side. The animals were divided into two groups of 2- and 6-week intervals and evaluated using histopathological and immunohistochemical techniques. Results: Histological evaluation revealed a significant difference between the experimental and the control groups after two weeks in osteoblast and osteocyte counts. The experimental group had mature bone development after six weeks of implantation, while the control group had a woven bone. Immunohistochemical results showed that the experimental group, compared to the control group, exhibited early positive expression of osteoblast cells at two weeks after the experiment. Based on histopathological observations, the experimental group showed a tiny area of collagenous fiber in 6th week after the implantation. Conclusion: A mixture of whey protein and M. oleifera could accelerate osseointegration and healing processes.


Moringa oleifera , Osseointegration , Plant Extracts , Plant Leaves , Whey Proteins , Animals , Whey Proteins/pharmacology , Rabbits , Osseointegration/drug effects , Moringa oleifera/chemistry , Plant Extracts/pharmacology , Plant Leaves/chemistry , Male , Osteoblasts/drug effects , Femur/drug effects , Osteogenesis/drug effects
16.
JBJS Case Connect ; 14(2)2024 Apr 01.
Article En | MEDLINE | ID: mdl-38608045

CASE: A 38-year-old man with congenital pain insensitivity underwent bilateral below-knee amputations. After his subsequent bilateral osseointegration (OI) limb replacements, he rapidly developed severe bilateral knee arthritis and varus deformity. In lieu of performing bilateral above-knee amputations, he underwent bilateral staged total knee arthroplasties (TKA) with excellent clinical and radiographic evaluation at 1-year follow-up. CONCLUSION: To address both the limited bone stock and OI implant stem location, TKA after OI limb replacement in congenital pain insensitivity patients can be successfully achieved with a nonkeeled cementless tibial component and augmentation with a tibial cone.


Arthroplasty, Replacement, Knee , Channelopathies , Pain Insensitivity, Congenital , Male , Humans , Adult , Osseointegration , Amputation, Surgical
17.
Ann Plast Surg ; 92(4S Suppl 2): S96-S100, 2024 Apr 01.
Article En | MEDLINE | ID: mdl-38556655

PURPOSE: Osseointegration (OI) is a novel alternative to traditional socket-suspended prostheses for lower-limb amputees, eliminating the socket-skin interface and allowing for weight bearing directly on the skeletal system. However, the stoma through which the implant attaches to the external prosthesis creates an ingress route for bacteria, and infection rates as high as 66% have been reported. The aims of this study are to classify infection management and long-term outcomes in this patient population to maximize implant salvage. METHODS: An institutional review board-approved retrospective analysis was performed on all patients who underwent lower-limb OI at our institution between 2017 and 2022. Demographic, operative, and outcome data were collected for all patients. Patients were stratified by the presence and severity of infection. Chi-square and t tests were performed on categorical and continuous data, respectively, using an alpha of 0.05. RESULTS: One hundred two patients met our study criteria; 62 had transfemoral OI and 40 had transtibial OI. Patients were followed for 23.8 months on average (range, 3.5-63.7). Osteomyelitis was more likely than soft tissue infection to be polymicrobial in nature (71% vs 23%, P < 0.05). Infections at the stoma were mostly (96%) managed with oral antibiotics alone, whereas deeper soft tissue infections also required intravenous antibiotics (75%) or operative washout (19%). Osteomyelitis was managed with intravenous antibiotics and required operative attention; 5 (71%) underwent washout and 2 (29%) underwent explantation. Both implants were replaced an average of 3.5 months after explantation. There was no correlation between history of soft tissue infection and development of osteomyelitis (P > 0.05). The overall implant salvage rate after infection was 96%. CONCLUSIONS: This study describes our institution's experience managing infection after OI and soft tissue reconstruction. Although infections do occur, they are easily treatable and rarely require operative intervention. Explantation due to infection is rare and can be followed up with reimplantation, reaffirming that OI is a safe and effective treatment modality.


Artificial Limbs , Osteomyelitis , Soft Tissue Infections , Humans , Osseointegration , Prosthesis Implantation , Retrospective Studies , Soft Tissue Infections/etiology , Artificial Limbs/adverse effects , Treatment Outcome , Anti-Bacterial Agents/therapeutic use , Osteomyelitis/etiology , Osteomyelitis/surgery
18.
Int J Implant Dent ; 10(1): 18, 2024 Apr 16.
Article En | MEDLINE | ID: mdl-38625587

PURPOSE: Osteoporotic individuals who have dental implants usually require a prolonged healing time for osseointegration due to the shortage of bone mass and the lack of initial stability. Although studies have shown that intermittent teriparatide administration can promote osseointegration, there is little data to support the idea that pre-implantation administration is necessary and beneficial. METHODS: Sixty-four titanium implants were placed in the bilateral proximal tibial metaphysis in 32 female SD rats. Bilateral ovariectomy (OVX) was used to induce osteoporosis. Four major groups (n = 8) were created: PRE (OVX + pre-implantation teriparatide administration), POST (OVX + post-implantation administration), OP (OVX + normal saline (NS)) and SHAM (sham rats + NS). Half of rats (n = 4) in each group were euthanized respectively at 4 weeks or 8 weeks after implantation surgery, and four major groups were divided into eight subgroups (PRE4 to SHAM8). Tibiae were collected for micro-CT morphometry, biomechanical test and undecalcified sections analysis. RESULTS: Compared to OP group, rats in PRE and SHAM groups had a higher value of insertion torque (p < 0.05). The micro-CT analysis, biomechanical test, and histological data showed that peri-implant trabecular growth, implants fixation and bone-implant contact (BIC) were increased after 4 or 8 weeks of teriparatide treatment (p < 0.05). There was no statistically difference in those parameters between PRE4 and POST8 subgroups (p > 0.05). CONCLUSIONS: In osteoporotic rats, post-implantation administration of teriparatide enhanced peri-implant bone formation and this effect was stronger as the medicine was taken longer. Pre-implantation teriparatide treatment improved primary implant stability and accelerated the osseointegration process.


Dental Implants , Teriparatide , Female , Animals , Rats , Rats, Sprague-Dawley , Teriparatide/pharmacology , Teriparatide/therapeutic use , Osseointegration , Embryo Implantation , Saline Solution
19.
Head Face Med ; 20(1): 24, 2024 Apr 16.
Article En | MEDLINE | ID: mdl-38627712

OBJECTIVES: A randomized controlled clinical trial of dental implants was conducted to compare the clinical properties of a novel electrochemically deposited calcium phosphate coating to those of a common marketed surface treatment. MATERIAL AND METHODS: Forty implants of the same brand and type were placed in 20 fully edentulous participants requiring mandibular implantation. The two study groups were defined by the surface treatment of the implants. 20 implants in the control group were coated via a commercial electrochemical surface treatment that forms a mixture of brushite and hydroxyapatite, while the remaining 20 in the test group were coated with a novel electrochemical Smart Bioactive Trabecular Coating (SBTC®). A split-mouth design was employed, with each participants receiving one control implant in one mandibular side and a test implant in the other. To mitigate potential operator-handedness bias, control and test implants were randomly assigned to mandibular sides. All cases underwent digital planning, implant placement with a static surgical guide, and participants received locator-anchored full-arch dentures. The primary outcome was implant stability (measured using Osstell ISQ) assessed at insertion, loading, and then 3 months, 9 months, and 2 years post-insertion. The secondary outcome was bone level change (in millimeters) over the 2-year observation period. Oral health-related quality of life (OHRQL) was monitored using the OHIP-14 questionnaire. Complications and adverse events were recorded. RESULTS: Successful osseointegration and implant stability were achieved in all cases, allowing loading. ISQ values steadily increased throughout the observation period. While no significant differences were observed between the SBTC® and control coatings, the test group exhibited a higher ISQ gain. Bone resorption was somewhat lower in the SBTC® but not significantly so. Patients' OHRQL significantly improved after denture delivery and remained stable throughout the follow-up. No complications or adverse events were observed. CONCLUSIONS: Based on the study results, we conclude that the new surface treatment is a safe alternative to the widely used control surface, demonstrating similar osseointegrative properties and time-dependent bone level changes. Further research may explore the broader implications of these findings. TRIAL REGISTRATION: The study is registered on clinicaltrials.gov under the identifier ID: NCT06034171.


Dental Implants , Mouth, Edentulous , Humans , Dental Implantation, Endosseous/methods , Quality of Life , Osseointegration , Treatment Outcome , Dental Prosthesis, Implant-Supported/methods , Dental Prosthesis Design
20.
PLoS One ; 19(4): e0300956, 2024.
Article En | MEDLINE | ID: mdl-38630711

Increasing the stem size during surgery is associated with a higher incidence of intraoperative periprosthetic fractures in cementless total hip arthroplasty with fully coated tapered wedge stems, especially in femurs of Dorr type A. If in contrast a stem is implanted and sufficient primary stability is not achieved, such preventing successful osseointegration due to increased micromotions, it may also fail, especially if the stem is undersized. Stem loosening or periprosthetic fractures due to stem subsidence can be the consequence. The adaptation of an established stem design to femurs of Dorr type A by design modifications, which increase the stem width proximally combined with a smaller stem tip and an overall shorter stem, might reduce the risk of distal locking of a proximally inadequately fixed stem and provide increased stability. The aim of this study was to investigate whether such a modified stem design provides improved primary stability without increasing the periprosthetic fracture risk compared to the established stem design. The established (Corail, DePuy Synthes, Warsaw, IN, US) and modified stem designs (Emphasys, DePuy Synthes, Warsaw, IN, US) were implanted in cadaveric femur pairs (n = 6 pairs) using the respective instruments. Broaching and implantation forces were recorded and the contact areas between the prepared cavity and the stem determined. Implanted stems were subjected to two different cyclic loading conditions according to ISO 7206-4 using a material testing machine (1 Hz, 600 cycles @ 80 to 800 N, 600 cycles @ 80 to 1600 N). Translational and rotational relative motions between stem and femur were recorded using digital image correlation. Broaching and implantation forces for the modified stem were up to 40% higher (p = 0.024), achieving a 23% larger contact area between stem and bone (R2 = 0.694, p = 0.039) resulting in a four times lower subsidence during loading (p = 0.028). The slight design modifications showed the desired effect in this in-vitro study resulting in a higher primary stability suggesting a reduced risk of loosening. The higher forces required during the preparation of the cavity with the new broaches and during implantation of the stem could bare an increased risk for intraoperative periprosthetic fractures, which did not occur in this study.


Arthroplasty, Replacement, Hip , Hip Prosthesis , Periprosthetic Fractures , Humans , Hip Prosthesis/adverse effects , Periprosthetic Fractures/epidemiology , Prosthesis Design , Arthroplasty, Replacement, Hip/adverse effects , Osseointegration , Femur/surgery , Reoperation/adverse effects , Retrospective Studies
...