Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 2.779
Filter
1.
PLoS One ; 19(6): e0301618, 2024.
Article in English | MEDLINE | ID: mdl-38843277

ABSTRACT

Periprosthetic tissue inflammation is a challenging complication arising in joint replacement surgeries, which is often caused by wear debris from polyethylene (PE) components. In this study, we examined the potential biological effects of grafting a [2-(methacryloyloxy)ethyl]dimethyl-(3-sulfopropyl)ammonium hydroxide (MEDSAH) polymer onto the surface of PE through a solvent-evaporation technique. J774A.1 macrophage-like cells and primary cultured mouse osteoblasts were treated with PE powder with or without the MEDSAH coating. MEDSAH grafting on PE substantially reduced the expression of pro-inflammatory cytokines and other mediators in primary cultured mouse osteoblasts, but did not significantly impact macrophage-mediated inflammation. Our findings suggest that a MEDSAH coating on PE-based materials has potential utility in mitigating periprosthetic tissue inflammation and osteolysis and preventing aseptic loosening in total joint replacements. Further research, including large-scale clinical trials and biomechanical analyses, is needed to assess the long-term performance and clinical implications of MEDSAH-coated PE-based materials in total joint arthroplasty.


Subject(s)
Inflammation , Osteoblasts , Polyethylene , Animals , Mice , Inflammation/pathology , Osteoblasts/metabolism , Osteoblasts/drug effects , Macrophages/metabolism , Cell Line , Cytokines/metabolism , Osteolysis/etiology , Osteolysis/pathology , Coated Materials, Biocompatible/chemistry , Methacrylates/chemistry , Arthroplasty, Replacement/adverse effects
2.
J Am Acad Orthop Surg ; 32(14): e726-e736, 2024 Jul 15.
Article in English | MEDLINE | ID: mdl-38709827

ABSTRACT

INTRODUCTION: Pelvic metastasis is a common presentation among patients presenting with skeletal metastasis. Image-guided percutaneous cementation of these lesions is becoming increasingly popular for the treatment of these lesions. The objective of this study was to conduct a systematic review that investigates clinical outcomes after percutaneous cementation for pelvic metastasis. METHODS: A systematic review was registered with International Prospective Register of Systematic Reviews and performed according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines using the PubMed, SCOPUS, and Ovid MEDLINE databases. All level I to IV clinical studies published in the English language investigating the clinical outcomes after percutaneous cementation for pelvic metastasis were included. RESULTS: Fourteen studies with 579 patients (278 men, 301 women) and 631 metastatic pelvic lesions were included in the study. The mean follow-up range was 0.7 to 26.4 months. Percutaneous cementation alone was performed in 441 patients (76.2%). Supplemental ablative procedures were performed in 77 patients (13.3%), and supplemental internal fixation using cannulated screws was performed in 107 patients (18.5%). Twelve studies with 430 patients (74.2%) reported pain-related and/or functional outcome scores, of which all studies reported overall clinically notable improvement at short-term follow-up. All studies reported periprocedural complications. Local cement leakage was the most common complication (162/631 lesions, 25.7%) followed by transient local pain (25/579 patients, 4.3%). There were no reported cases of major complications. Seven patients (1.2%) underwent re-intervention for persistent symptoms. CONCLUSIONS: Percutaneous cementation may be an effective method for treating pain and function related to pelvic metastasis. The most common complication was cement leakage surrounding the lesion. The rates of major complications were low, and most complications appeared minor and transient. Additional prospective studies are needed to further assess the efficacy of this procedure. LEVEL OF EVIDENCE: IV, systematic review of level I to IV therapeutic studies.


Subject(s)
Bone Cements , Bone Neoplasms , Pelvic Bones , Humans , Bone Neoplasms/secondary , Bone Neoplasms/surgery , Bone Neoplasms/complications , Bone Cements/therapeutic use , Osteolysis/etiology , Cementation , Treatment Outcome , Female , Pelvic Neoplasms/secondary , Male
3.
Pathologie (Heidelb) ; 45(4): 284-289, 2024 Jul.
Article in German | MEDLINE | ID: mdl-38602523

ABSTRACT

We report a rarely occurring hematologic neoplasm in a young adult. Hematologic neoplasms were first described in 2008 and are now included in both accepted tumor classification systems, i.e., International Consensus Classification and World Health Organization. This hematologic neoplasm shows a characteristic ALK positivity in immunohistochemical examination and correspondingly, ALK fusion genes in the molecular analysis. Pathologists should be aware of this entity, particularly as it is challenging to differentiate from other more frequent neoplasms of the same disease group or mesenchymal neoplasm with ALK aberration.


Subject(s)
Osteolysis , Humans , Diagnosis, Differential , Osteolysis/pathology , Osteolysis/diagnosis , Osteolysis/diagnostic imaging , Osteolysis/etiology , Mandibular Neoplasms/pathology , Mandibular Neoplasms/diagnosis , Mandibular Neoplasms/genetics , Male , Adult , Anaplastic Lymphoma Kinase/genetics , Young Adult , Female
4.
Bone Joint J ; 106-B(5 Supple B): 59-65, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38688488

ABSTRACT

Aims: Isolated acetabular liner exchange with a highly crosslinked polyethylene (HXLPE) component is an option to address polyethylene wear and osteolysis following total hip arthroplasty (THA) in the presence of a well-fixed acetabular shell. The liner can be fixed either with the original locking mechanism or by being cemented within the acetabular component. Whether the method used for fixation of the HXLPE liner has any bearing on the long-term outcomes is still unclear. Methods: Data were retrieved for all patients who underwent isolated acetabular component liner exchange surgery with a HXLPE component in our institute between August 2000 and January 2015. Patients were classified according to the fixation method used (original locking mechanism (n = 36) or cemented (n = 50)). Survival and revision rates were compared. A total of 86 revisions were performed and the mean duration of follow-up was 13 years. Results: A total of 20 patients (23.3%) had complications, with dislocation alone being the most common (8.1%; 7/86). Ten patients (11.6%) required re-revision surgery. Cementing the HXLPE liner (8.0%; 4/50) had a higher incidence of re-revision due to acetabular component liner-related complications than using the original locking mechanism (0%; 0/36; p = 0.082). Fixation using the original locking mechanism was associated with re-revision due to acetabular component loosening (8.3%; 3/36), compared to cementing (0%; 0/50; p = 0.038). Overall estimated mean survival was 19.2 years. There was no significant difference in the re-revision rate between the original locking mechanism (11.1%; 4/36) and cementing (12.0%; 6/50; p = 0.899). Using Kaplan-Meier survival analysis, the revision-free survival of HXLPE fixed with the original locking mechanism and cementing was 94.1% and 93.2%, respectively, at ten years, and 84.7% and 81.3%, respectively, at 20 years (p = 0.840). Conclusion: The re-revision rate and the revision-free survival following acetabular component liner exchange revision surgery using the HXLPE liner were not influenced by the fixation technique used. Both techniques were associated with good survival at a mean follow-up of 13 years. Careful patient selection is necessary for isolated acetabular component liner exchange revision surgery in order to achieve the best outcomes.


Subject(s)
Acetabulum , Arthroplasty, Replacement, Hip , Hip Prosthesis , Osteolysis , Polyethylene , Prosthesis Design , Prosthesis Failure , Reoperation , Humans , Arthroplasty, Replacement, Hip/methods , Arthroplasty, Replacement, Hip/instrumentation , Osteolysis/etiology , Female , Male , Middle Aged , Aged , Acetabulum/surgery , Retrospective Studies , Adult , Aged, 80 and over , Follow-Up Studies
5.
Bone Joint J ; 106-B(3 Supple A): 38-43, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38423114

ABSTRACT

Aims: Oxidized zirconium (OxZi) and highly cross-linked polyethylene (HXLPE) were developed to minimize wear and risk of osteolysis in total hip arthroplasty (THA). However, retrieval studies have shown that scratched femoral heads may lead to runaway wear, and few reports of long-term results have been published. The purpose of this investigation is to report minimum ten-year wear rates and clinical outcomes of THA with OxZi femoral heads on HXLPE, and to compare them with a retrospective control group of cobalt chrome (CoCr) or ceramic heads on HXLPE. Methods: From 2003 to 2006, 108 THAs were performed on 96 patients using an OxZi head with a HXLPE liner with minimum ten-year follow-up. Harris Hip Scores (HHS) were collected preoperatively and at the most recent follow-up (mean 13.3 years). Linear and volumetric liner wear was measured on radiographs of 85 hips with a minimum ten-year follow-up (mean 14.5 years). This was compared to a retrospective control group of 45 THAs using ceramic or CoCr heads from October 1999 to February 2005, with a minimum of ten years' follow-up. Results: Average HHS improved from 50.8 to 91.9 and 51.0 to 89.8 in the OxZi group and control group, respectively (p = 0.644), with no osteolysis in either group. Linear and volumetric wear rates in the OxZi group averaged 0.03 mm/year and 3.46 mm3/year, respectively. There was no statistically significant difference in HHS scores, nor in linear or volumetric wear rate between the groups, and no revision for any indication. Conclusion: The radiological and clinical outcomes, and survivorship of THA with OxZi femoral heads and HXLPE liners, were excellent, and comparable to CoCr or ceramic heads at minimum ten-year follow-up. Wear rates are below what would be expected for development of osteolysis. OxZi-HXLPE is a durable bearing couple with excellent long-term outcomes.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Osteolysis , Humans , Polyethylene , Zirconium , Retrospective Studies , Femur Head/surgery , Osteolysis/etiology , Osteolysis/surgery , Prosthesis Failure , Prosthesis Design , Chromium Alloys
6.
Foot Ankle Clin ; 29(1): 123-143, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38309797

ABSTRACT

Total ankle arthroplasty (TAA) has become a popular management option for ankle arthritis. Periprosthetic osteolysis is one of the most common causes for reoperation in TAA. A CT scan should be done in all suspected osteolysis cases to confirm location, quantify size and aid in surgical planning. These patients are often asymptomatic with limited evidence regarding appropriate management. Smaller lesions should be monitored for progression in size. Periprosthetic cysts measuring 10-15mm in all three axes should be considered for debridment and curettage with autogenous bone grafting. The authors believe that bone grafting of large asymptomatic periprosthetic cysts could prevent implant failure.


Subject(s)
Arthroplasty, Replacement, Ankle , Cysts , Joint Prosthesis , Osteolysis , Humans , Ankle/surgery , Bone Transplantation , Osteolysis/etiology , Retrospective Studies , Arthroplasty, Replacement, Ankle/adverse effects , Joint Prosthesis/adverse effects , Cysts/complications , Cysts/surgery , Ankle Joint/surgery , Curettage/adverse effects , Reoperation/adverse effects
7.
J Arthroplasty ; 39(7): 1845-1855, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38336308

ABSTRACT

BACKGROUND: Aseptic loosening around the prosthesis is a common cause of failure in total joint arthroplasty. Polyethylene wear particles trigger the release of inflammatory factors by macrophages. Key mediators involved in osteoclastogenesis include interleukin-6, tumor necrosis factor-α, receptor activator of nuclear factor kappa B (RANK), RANK ligand (RANKL), and bone protection hormone (Osteoprotegerin [OPG]). The purpose of our experiment was to see whether melittin can slow down the release of inflammatory mediators through the NF-kB pathway, regulate the RANKL/OPG ratio, reduce osteoclast formation, and delay the onset of arthritis in rats. METHODS: A total of 20 male Sprague-Dawley rats (10 months, Specific Pathogen Free, 350 g ± 20 g) were randomly divided into 5 groups: sham group, model group, melittin concentration 1 group (0.2 mg/kg), concentration 2 group (0.4 mg/kg), and concentration 3 group (0.6 mg/kg). All rats were implanted with TA2 high-purity titanium rods. A drill was used to create a bone canal along the long axis of the femur in the intercondylar notch. The model group and experimental groups were exposed to polyethylene particles, while the sham group did not receive any particles. RESULTS: The melittin group exhibited significantly increased serum levels of serum P, calcium-phosphorus product, OPG, PINP, PINP/CTX-I, and OPG/RANKKL (P < .05). In the experimental group, micro computed tomography scanning results revealed a decrease in the amount of bone defect around the prosthesis. Immunofluorescence analysis demonstrated a decrease in the expression of IKKα and P65, while the expression of OPG showed an upward trend. Both Hematoxylin-Eosin and Tartrate-Resistant Acid Phosphatase staining revealed less osteoclast and inflammatory cell infiltration in bone resorption pits. CONCLUSIONS: Our study demonstrates that melittin has the ability to inhibit the NF-kB pathway in a rat model, and reduce the impact of RANKL/OPG, thereby delaying osteoclast activity and alleviating periprosthetic osteolysis.


Subject(s)
Disease Models, Animal , Melitten , NF-kappa B , Osteolysis , Osteoprotegerin , RANK Ligand , Rats, Sprague-Dawley , Animals , Male , Osteolysis/etiology , Osteolysis/prevention & control , RANK Ligand/metabolism , Osteoprotegerin/metabolism , Rats , Melitten/pharmacology , NF-kappa B/metabolism , Titanium , Osteoclasts/drug effects , Signal Transduction/drug effects , Polyethylene , Prosthesis Failure
8.
Sci Adv ; 10(8): eadj0975, 2024 Feb 23.
Article in English | MEDLINE | ID: mdl-38381833

ABSTRACT

Breast cancer often metastasizes to bone, causing osteolytic lesions. Structural and biophysical changes are rarely studied yet are hypothesized to influence metastasis. We developed a mouse model of early bone metastasis and multimodal imaging to quantify cancer cell homing, bone (re)modeling, and onset of metastasis. Using tissue clearing and three-dimensional (3D) light sheet fluorescence microscopy, we located enhanced green fluorescent protein-positive cancer cells and small clusters in intact bones and quantified their size and spatial distribution. We detected early bone lesions using in vivo microcomputed tomography (microCT)-based time-lapse morphometry and revealed altered bone (re)modeling in the absence of detectable lesions. With a new microCT image analysis tool, we tracked the growth of early lesions over time. We showed that cancer cells home in all bone compartments, while osteolytic lesions are only detected in the metaphysis, a region of high (re)modeling. Our study suggests that higher rates of (re)modeling act as a driver of lesion formation during early metastasis.


Subject(s)
Bone Neoplasms , Osteolysis , Animals , Mice , X-Ray Microtomography/methods , Bone Neoplasms/complications , Bone Neoplasms/secondary , Bone and Bones/diagnostic imaging , Osteolysis/diagnostic imaging , Osteolysis/etiology , Osteolysis/pathology , Disease Models, Animal , Cell Line, Tumor
9.
Eur Spine J ; 33(3): 1292-1299, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38363365

ABSTRACT

INTRODUCTION: A recent study reported a 34% mid-term revision rate after M6-C™ cervical total disc replacement (CTDR) for wear-related osteolysis. Here, we aim to investigate the prevalence, risk factors, and radiographic characteristics of periprosthetic bony changes and implant failure of the M6-C™ artificial disc. METHODS: We retrospectively analysed radiographic (conventional X-ray, CT scan) and clinical outcomes (EQ-5D-5L, Neck Disability Index (NDI), and Visual Analog Scale (VAS) for neck and arm pain) data collected during routine follow-up of patients who underwent CTDR with the M6-C™ between 2011 and 2015. RESULTS: In total, 85 patients underwent CTDR with the M6-C™. Follow-up data were available for 43 patients (54% female, mean age 44 years) with 50 implants and a mean follow-up of 8.1 years (6.5-11 years). Implant failure with the presence of severe osteolysis was identified in 5 (12%) patients who were all male (p = 0.016) and implanted at the C5/6 level (p = 0.11). All failed implants required revision surgery. The overall prevalence of osteolysis was 44% (22/50 implants) and 34% (17/50 implants) for significant heterotopic ossification. Patients with high-grade osteolysis showed higher VAS arm pain (p = 0.05) and lower EQ-5D-VAS health VAS (p = 0.03). CONCLUSION: We report a lower reoperation rate for failed M6-C™ implants than previously published, but confirmed that osteolysis and heterotopic ossification are common following CTDR with the M6-C™ and may be asymptomatic. Therefore, we strongly recommend ongoing clinical and radiographic monitoring after CTDR with the M6-C™, particularly for male patients implanted at the C5/6 level.


Subject(s)
Intervertebral Disc Degeneration , Ossification, Heterotopic , Osteolysis , Total Disc Replacement , Humans , Male , Female , Adult , Total Disc Replacement/adverse effects , Treatment Outcome , Follow-Up Studies , Intervertebral Disc Degeneration/surgery , Retrospective Studies , Osteolysis/diagnostic imaging , Osteolysis/epidemiology , Osteolysis/etiology , Cervical Vertebrae/diagnostic imaging , Cervical Vertebrae/surgery , Neck Pain/etiology , Ossification, Heterotopic/diagnostic imaging , Ossification, Heterotopic/epidemiology , Ossification, Heterotopic/etiology
11.
JBJS Case Connect ; 14(1)2024 Jan 01.
Article in English | MEDLINE | ID: mdl-38181104

ABSTRACT

CASE: A 15-year-old girl known with osteogenesis imperfecta presented with left femoral pain. She had been treated with multiple Fassier-Duval intramedullary nails, which were still in situ. Radiographic imaging demonstrated focal osteolysis and periosteal reaction at the telescopic junction of the rod in the distal femur. She underwent implant removal. Intraoperative sampling demonstrating acute sterile inflammation and presence of brownish colored particles consistent with metal debris and osteolysis. Explant analysis confirmed corrosion of the stainless-steel telescopic nail as the underlying cause. CONCLUSION: Osteolysis and periosteal reaction because of corrosion should be considered in conjunction with other more common causes of pain, such as fracture or infection, in patients treated with telescopic intramedullary nails.


Subject(s)
Osteolysis , Female , Humans , Adolescent , Osteolysis/diagnostic imaging , Osteolysis/etiology , Corrosion , Device Removal , Femur , Pain
12.
J ISAKOS ; 9(3): 410-414, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38266965

ABSTRACT

Numerous interference screws of different compositions exist including titanium screws, bioabsorbable screws, and polyetheretherketone (PEEK) screws. PEEK-based implants are frequently used in orthopaedic surgery due to their biocompatibility, similar elastic modulus to cortical bone, and purported negligible risk of osteolysis compared with bioabsorbable screws. In this case report, we present the case of a 48-year-old healthy female who experienced a massive osteolytic reaction in the talus and fibula after 11 weeks following implantation of PEEK-based interference screws during lateral ankle ligament reconstruction. The patient subsequently underwent removal of the PEEK screws and specimens were sent for microbiological and histopathological analysis. The specimens report demonstrated fibrotic tenosynovial soft tissue with patchy chronic inflammation, oedematous reactive changes, and histiocytic reaction, with no evidence of any significant acute inflammation. The patient recovered well and was asymptomatic at 6 months postoperatively. To our knowledge, this is the first case report of a massive osteolytic reaction to PEEK-based interference screws.


Subject(s)
Benzophenones , Bone Screws , Fibula , Ketones , Osteolysis , Polyethylene Glycols , Polymers , Talus , Humans , Female , Middle Aged , Osteolysis/etiology , Bone Screws/adverse effects , Ketones/adverse effects , Polyethylene Glycols/adverse effects , Polymers/adverse effects , Fibula/surgery , Talus/surgery , Biocompatible Materials/adverse effects
13.
J Shoulder Elbow Surg ; 33(7): 1465-1472, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38182025

ABSTRACT

BACKGROUND: Particle-induced osteolysis resulting from polyethylene wear remains a source of implant failure in anatomic total shoulder designs. Modern polyethylene components are irradiated in an oxygen-free environment to induce cross-linking, but reducing the resulting free radicals with melting or heat annealing can compromise the component's mechanical properties. Vitamin E has been introduced as an adjuvant to thermal treatments. Anatomic shoulder arthroplasty models with a ceramic head component have demonstrated that vitamin E-enhanced polyethylene show improved wear compared with highly cross-linked polyethylene (HXLPE). This study aimed to assess the biomechanical wear properties and particle size characteristics of a novel vitamin E-enhanced highly cross-linked polyethylene (VEXPE) glenoid compared to a conventional ultrahigh-molecular-weight polyethylene (UHMWPE) glenoid against a cobalt chromium molybdenum (CoCrMo) head component. METHODS: Biomechanical wear testing was performed to compare the VEXPE glenoid to UHMWPE glenoid with regard to pristine polyethylene wear and abrasive endurance against a polished CoCrMo alloy humeral head in an anatomic shoulder wear-simulation model. Cumulative mass loss (milligrams) was recorded, and wear rate calculated (milligrams per megacycle [Mc]). Under pristine wear conditions, particle analysis was performed, and functional biologic activity (FBA) was calculated to estimate particle debris osteolytic potential. In addition, 95% confidence intervals for all testing conditions were calculated. RESULTS: The average pristine wear rate was statistically significantly lower for the VEXPE glenoid compared with the HXLPE glenoid (0.81 ± 0.64 mg/Mc vs. 7.00 ± 0.45 mg/Mc) (P < .05). Under abrasive wear conditions, the VEXPE glenoid had a statistically significant lower average wear rate compared with the UHMWPE glenoid comparator device (18.93 ± 5.80 mg/Mc vs. 40.47 ± 2.63 mg/Mc) (P < .05). The VEXPE glenoid demonstrated a statistically significant improvement in FBA compared with the HXLPE glenoid (0.21 ± 0.21 vs. 1.54 ± 0.49 (P < .05). CONCLUSIONS: A new anatomic glenoid component with VEXPE demonstrated significantly improved pristine and abrasive wear properties with lower osteolytic particle debris potential compared with a conventional UHMWPE glenoid component. Vitamin E-enhanced polyethylene shows early promise in shoulder arthroplasty components. Long-term clinical and radiographic investigation needs to be performed to verify if these biomechanical wear properties translate to diminished long-term wear, osteolysis, and loosening.


Subject(s)
Arthroplasty, Replacement, Shoulder , Materials Testing , Polyethylenes , Prosthesis Design , Prosthesis Failure , Shoulder Prosthesis , Vitamin E , Humans , Arthroplasty, Replacement, Shoulder/methods , Biomechanical Phenomena , Particle Size , Osteolysis/etiology , Osteolysis/prevention & control , Shoulder Joint/surgery
14.
Haematologica ; 109(7): 2207-2218, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38205555

ABSTRACT

Osteolytic bone lesion is a major cause of lower quality of life and poor prognosis in patients with multiple myeloma (MM), but molecular pathogenesis of the osteolytic process in MM remains elusive. Fms-like tyrosine kinase 3 ligand (FLT3L) was reported to be elevated in bone marrow (BM) and blood of patients with advanced MM who often show osteolysis. Here, we investigated a functional link of FLT3L to osteolytic process in MM. We recruited 86, 306, and 52 patients with MM, acute myeloid leukemia (AML), and acute lymphoblastic leukemia (ALL), respectively. FLT3L levels of patients with hematologic malignancies were measured in BM-derived plasma and found to be significantly higher in MM than in AML or ALL, which rarely show osteolysis. FLT3L levels were further elevated in MM patients with bone lesion compared with patients without bone lesion. In vitro cell-based assays showed that the administration of FLT3L to HEK293T, HeLa, and U2OS cells led to an increase in the DKK1 transcript level through STAT3 phosphorylation at tyrosine 705. WNT reporter assay showed that FLT3L treatment reduced WNT signaling and nuclear translocation of ß-catenin. These results collectively show that the FLT3L-STAT3-DKK1 pathway inhibits WNT signaling-mediated bone formation in MM, which can cause osteolytic bone lesion. Finally, transcriptomic profiles revealed that FLT3L and DKK1 were predominantly elevated in the hyperdiploidy subtype of MM. Taken together, FLT3L can serve as a promising biomarker for predicting osteolytic bone lesion and also a potential therapeutic target to prohibit the progression of the osteolytic process in MM with hyperdiploidy.


Subject(s)
Multiple Myeloma , Osteolysis , Humans , Multiple Myeloma/genetics , Multiple Myeloma/pathology , Multiple Myeloma/metabolism , Osteolysis/pathology , Osteolysis/genetics , Osteolysis/etiology , Wnt Signaling Pathway , Male , Female , Middle Aged , Aged , Cell Line, Tumor , STAT3 Transcription Factor/metabolism , STAT3 Transcription Factor/genetics , Neoplasm Staging , Intercellular Signaling Peptides and Proteins/genetics , Intercellular Signaling Peptides and Proteins/metabolism , Adult
15.
J Orthop Sci ; 29(2): 521-528, 2024 Mar.
Article in English | MEDLINE | ID: mdl-36710212

ABSTRACT

BACKGROUND: Stress shielding and osteolysis around the humeral stem after reverse shoulder arthroplasty causes loosening and periprosthetic fractures and reduces bone stock during revision surgery. In Japanese patients, who have relatively small bodies, different characteristics may exist regarding the occurrence of these changes compared with the characteristics of Westerners, who have relatively larger frames. The purpose of this multicenter study was to investigate the incidence and clarify the predictors of stress shielding and osteolysis in Japanese individuals who underwent reverse shoulder arthroplasty. METHODS: The occurrence of stress shielding and osteolysis was investigated in 135 shoulders that had undergone reverse shoulder arthroplasty at least 2 years prior in five Japanese hospitals. During post-surgical follow-up, which was conducted every 3 months, the locations of the stress shielding occurrences, such as cortical thinning and osteopenia (which primarily occurred in zones 1, 2, and 7, where 1 is the greater tuberosity and 7 is the calcar part), spot weld, and condensation lines, were recorded. Cases without any abnormal findings on radiographs obtained up to ≥2 years after surgery were regarded as having no abnormalities. Finally, the predictors of cortical thinning and proximal humeral osteolysis were assessed using univariate and multivariate regression analyses. RESULTS: Cortical thinning and osteopenia occurred in 68 shoulders, a condensation line occurred in 37 shoulders, and spot weld occurred in 23 shoulders. In particular, greater tuberosity and calcar osteolysis occurred in 40 and 47 shoulders, respectively. Long stem, cementless stem, and a larger proximal filling ratio were independent predictors of cortical thinning and osteopenia, whereas a cementless stem, larger metaphysis diameter, and a larger proximal filling ratio were associated with proximal humeral osteolysis. CONCLUSIONS: The predictors of stress shielding and osteolysis included the use of long stems, cementless stems, larger proximal filling ratios, and larger metaphysis diameters. LEVEL OF EVIDENCE: retrospective comparative study (Level III).


Subject(s)
Arthroplasty, Replacement, Shoulder , Bone Diseases, Metabolic , Osteolysis , Shoulder Joint , Humans , Arthroplasty, Replacement, Shoulder/adverse effects , Shoulder Joint/diagnostic imaging , Shoulder Joint/surgery , Osteolysis/diagnostic imaging , Osteolysis/epidemiology , Osteolysis/etiology , Retrospective Studies , Cerebral Cortical Thinning , Japan/epidemiology , Treatment Outcome , Humerus/surgery
16.
J Hand Surg Eur Vol ; 49(1): 34-39, 2024 01.
Article in English | MEDLINE | ID: mdl-37666215

ABSTRACT

We present five cases of osteolysis in the Motec total wrist prosthesis, three around the radial implant, one around the metacarpal implant and one around both. Three of these were progressive and required revision, and biomechanical explant analyses of these revised prostheses were performed. Ex vivo testing of the contact points of the Motec implants was also performed at maximum extension. Here, impingement occurs between the metacarpal screw and the dorsal rim of the cup (non-articulating surfaces) with the short-necked prosthesis, leading to metacarpal screw damage, titanium debris formation and osteolysis. An analysis of three previously published cases suggests that this may have been the likely mode of failure in those cases. This complication is preventable by avoiding use of the short-neck prosthesis.Level of evidence: IV.


Subject(s)
Arthroplasty, Replacement , Joint Prosthesis , Osteolysis , Humans , Osteolysis/etiology , Osteolysis/surgery , Wrist , Arthroplasty, Replacement/adverse effects , Joint Prosthesis/adverse effects , Prosthesis Failure , Prosthesis Design
17.
Eur J Orthop Surg Traumatol ; 34(1): 251-269, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37439887

ABSTRACT

AIM: Polymers and metals, such as polyethylene (PE) and cobalt chrome (CoCr), are common materials used in thumb-based joint implants, also known as CMC (Carpometacarpal) arthroplasty. The purpose of this review was to investigate the reported failure modes related to wear debris from these type of materials in CMC implants. The impact of wear debris on clinical outcomes of CMC implants was also examined. Potential adverse wear conditions and inflammatory particle characteristics were also considered. METHOD: A literature search was performed using PRISMA guidelines and 55 studies were reviewed including 49 cohort studies and 6 case studies. Of the 55 studies, 38/55 (69%) focused on metal-on-polyethylene devices, followed by metal-on-metal (35%), and metal-on-bone (4%). RESULTS: The summarized data was used to determine the frequency of failure modes potentially related to wear debris from metals and/or polymers. The most commonly reported incidents potentially relating to debris were implant loosening (7.1%), osteolysis (1.2%) and metallosis (0.6%). Interestingly the reported mechanisms behind osteolysis and loosening greatly varied. Inflammatory reactions, while rare, were generally attributed to metallic debris from metal-on-metal devices. Mechanisms of adverse wear conditions included implant malpositioning, over-tensioning, high loading for active patients, third-body debris, and polyethylene wear-through. No specific examination of debris particle characterization was found, pointing to a gap in the literature. CONCLUSION: This review underscores the types of failure modes associated with wear debris in CMC implants. It was found that failure rates and adverse wear conditions of CMC implants of any design are low and the exact relationship between wear debris and implant incidences, such as osteolysis and loosening remains uncertain. The authors note that further research and specific characterization is required to understand the relationship between debris and implant failure.


Subject(s)
Osteolysis , Humans , Osteolysis/etiology , Thumb/surgery , Prostheses and Implants/adverse effects , Polyethylene , Arthroplasty/adverse effects , Metals , Prosthesis Failure
18.
J Arthroplasty ; 39(2): 409-415, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37572728

ABSTRACT

BACKGROUND: Highly cross-linked polyethylene (HXLPE) acetabular bearing surfaces have appeared to offer excellent wear resistance, low incidence of wear-related osteolysis, and high implant survivorship at 10-year to 15-year follow-up. However, concerns over potential performance deterioration at longer-term follow-up remain - particularly in younger patients - and outcome data into the third decade have not been available. METHODS: We retrospectively assessed 62 patients (68 hips) who underwent primary total hip arthroplasty (THA) at age ≤50 years with a single manufacturer's cementless components, remelted HXLPE liner, and small diameter (26 and 28 millimeter) cobalt-chromium (CoCr) femoral heads at minimum 18-year follow-up. We assessed clinical outcomes (modified Harris Hip score, University of California Los Angeles Activity Score, polyethylene wear rates, radiographic findings (osteolysis, component loosening), and implant survivorship. RESULTS: At 20.6-year mean follow-up (range, 18 to 23 years) modified Harris Hip scores for surviving hips remained an average of 41 points above preoperative baseline (49 versus 90, P < .001) and UCLA scores 2.8 points above baseline (3.7 versus 6.4, P < .001). Wear analysis revealed a population linear wear rate of 0.0142 mm/y (standard deviation (SD), 0.0471) and volumetric wear rate of 10.14 mm3/y (SD, 23.41). Acetabular lysis was noted in 2 asymptomatic hips at 16.6 and 18.4 years. No components were radiographically loose. Survivorship free from wear-related revision was 100% at 20 years (97% free from any revision). CONCLUSION: The HXLPE-CoCr bearing couple with small femoral heads continues to be extremely effective 20 years after primary THA in the younger patient population.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Osteolysis , Humans , Middle Aged , Arthroplasty, Replacement, Hip/adverse effects , Polyethylene , Hip Prosthesis/adverse effects , Retrospective Studies , Chromium , Cobalt , Femur Head/surgery , Osteolysis/etiology , Prosthesis Failure , Prosthesis Design , Follow-Up Studies
19.
Ann Otol Rhinol Laryngol ; 133(2): 239-243, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37534717

ABSTRACT

OBJECTIVES: To report a case of a 71-year-old woman who presented 8 years following 2 endoscopic brow lift procedures for evaluation of bony irregularities of her frontoparietal skull. To highlight a novel complication of Endotine fixation following an endoscopic brow lift procedure. METHODS: A chart review, bicoronal cranioplasty and a review of literature. RESULTS: The patient was satisfied with her post-surgical outcome and no complications were observed at the 1-month follow-up visit. A review of the literature revealed no previous reports of focal skull osteolysis relating to Endotine implants. CONCLUSION: We believe that our patient's focal calvarial osteolysis is a direct complication of Endotine fixation. Future research into the long-term effects of endoscopic brow lift procedures using Endotine implants is necessary to help ensure patient safety and guide future practices.


Subject(s)
Osteolysis , Rhytidoplasty , Humans , Female , Aged , Osteolysis/etiology , Osteolysis/surgery , Eyebrows , Rhytidoplasty/methods , Endoscopy , Skull/surgery
SELECTION OF CITATIONS
SEARCH DETAIL
...