Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 5.696
Filter
1.
Support Care Cancer ; 32(7): 470, 2024 Jun 29.
Article in English | MEDLINE | ID: mdl-38951291

ABSTRACT

PURPOSE: This study aimed to compare the effects of a mobile health intervention based on social cognitive theory with standard care on maximal mouth opening, exercise compliance, and self-efficacy in patients receiving proton and heavy ion therapy for head and neck cancer. METHODS: This open-label, parallel-group, randomized, superiority trial involved a self-developed "Health Enjoy System" intervention. We assessed maximal mouth opening, exercise compliance, and self-efficacy at baseline (T0), post-treatment (T1), and at 1 month (T2) and 3 months (T3) after radiotherapy. Generalized estimating equations were used to analyze differences between the groups over time, with results reported as P values and 95% confidence intervals (CIs). RESULTS: The study included 44 participants. At T3, the intervention group showed a 6 mm greater increase in maximal interincisal opening than the control group (mean difference = 6.0, 95% CI = 2.4 to 9.5, P = 0.001). There was also a significant difference in exercise compliance between the groups (mean difference = 31.7, 95% CI = 4.6 to 58.8, P = 0.022). However, no significant difference in self-efficacy was found between the groups. CONCLUSION: This study demonstrated that an mHealth intervention incorporating behavior change theory could effectively enhance or maintain maximal mouth opening in patients undergoing proton and heavy ion therapy for head and neck cancer in China. This approach provides valuable support during and after treatment. TRIAL REGISTRATION: ChiCTR: ChiCTR2300067550. Registered 11 Jan 2023.


Subject(s)
Head and Neck Neoplasms , Proton Therapy , Self Efficacy , Telemedicine , Trismus , Humans , Head and Neck Neoplasms/radiotherapy , Head and Neck Neoplasms/complications , Head and Neck Neoplasms/therapy , Male , Middle Aged , Female , Proton Therapy/methods , Trismus/etiology , Trismus/therapy , Heavy Ion Radiotherapy/methods , Exercise Therapy/methods , Aged , Patient Compliance/statistics & numerical data , Adult
2.
Cells ; 13(12)2024 Jun 19.
Article in English | MEDLINE | ID: mdl-38920686

ABSTRACT

The use of charged particle radiotherapy is currently increasing, but combination therapy with DNA repair inhibitors remains to be exploited in the clinic. The high-linear energy transfer (LET) radiation delivered by charged particles causes clustered DNA damage, which is particularly effective in destroying cancer cells. Whether the DNA damage response to this type of damage is different from that elicited in response to low-LET radiation, and if and how it can be targeted to increase treatment efficacy, is not fully understood. Although several preclinical studies have reported radiosensitizing effects when proton or carbon ion irradiation is combined with inhibitors of, e.g., PARP, ATR, ATM, or DNA-PKcs, further exploration is required to determine the most effective treatments. Here, we examine what is known about repair pathway choice in response to high- versus low-LET irradiation, and we discuss the effects of inhibitors of these pathways when combined with protons and carbon ions. Additionally, we explore the potential effects of DNA repair inhibitors on antitumor immune signaling upon proton and carbon ion irradiation. Due to the reduced effect on healthy tissue and better immune preservation, particle therapy may be particularly well suited for combination with DNA repair inhibitors.


Subject(s)
DNA Damage , DNA Repair , Heavy Ion Radiotherapy , Proton Therapy , Humans , DNA Repair/drug effects , Neoplasms/drug therapy , Neoplasms/radiotherapy , Animals , Linear Energy Transfer
3.
Radiat Oncol ; 19(1): 78, 2024 Jun 24.
Article in English | MEDLINE | ID: mdl-38915112

ABSTRACT

PURPOSE: This study aims to develop an ensemble machine learning-based (EML-based) risk prediction model for radiation dermatitis (RD) in patients with head and neck cancer undergoing proton radiotherapy, with the goal of achieving superior predictive performance compared to traditional models. MATERIALS AND METHODS: Data from 57 head and neck cancer patients treated with intensity-modulated proton therapy at Kaohsiung Chang Gung Memorial Hospital were analyzed. The study incorporated 11 clinical and 9 dosimetric parameters. Pearson's correlation was used to eliminate highly correlated variables, followed by feature selection via LASSO to focus on potential RD predictors. Model training involved traditional logistic regression (LR) and advanced ensemble methods such as Random Forest and XGBoost, which were optimized through hyperparameter tuning. RESULTS: Feature selection identified six key predictors, including smoking history and specific dosimetric parameters. Ensemble machine learning models, particularly XGBoost, demonstrated superior performance, achieving the highest AUC of 0.890. Feature importance was assessed using SHAP (SHapley Additive exPlanations) values, which underscored the relevance of various clinical and dosimetric factors in predicting RD. CONCLUSION: The study confirms that EML methods, especially XGBoost with its boosting algorithm, provide superior predictive accuracy, enhanced feature selection, and improved data handling compared to traditional LR. While LR offers greater interpretability, the precision and broader applicability of EML make it more suitable for complex medical prediction tasks, such as predicting radiation dermatitis. Given these advantages, EML is highly recommended for further research and application in clinical settings.


Subject(s)
Head and Neck Neoplasms , Machine Learning , Proton Therapy , Radiodermatitis , Humans , Head and Neck Neoplasms/radiotherapy , Proton Therapy/adverse effects , Radiodermatitis/etiology , Male , Female , Middle Aged , Aged , Radiotherapy, Intensity-Modulated/adverse effects , Radiotherapy, Intensity-Modulated/methods , Risk Assessment , Radiotherapy Dosage , Adult
4.
Phys Med Biol ; 69(13)2024 Jun 26.
Article in English | MEDLINE | ID: mdl-38843812

ABSTRACT

Objective. In current clinical practice for quality assurance (QA), intensity modulated proton therapy (IMPT) fields are verified by measuring planar dose distributions at one or a few selected depths in a phantom. A QA device that measures full 3D dose distributions at high spatiotemporal resolution would be highly beneficial for existing as well as emerging proton therapy techniques such as FLASH radiotherapy. Our objective is to demonstrate feasibility of 3D dose measurement for IMPT fields using a dedicated multi-layer strip ionization chamber (MLSIC) device.Approach.Our developed MLSIC comprises a total of 66 layers of strip ion chamber (IC) plates arranged, alternatively, in thexandydirection. The first two layers each has 128 channels in 2 mm spacing, and the following 64 layers each has 32/33 IC strips in 8 mm spacing which are interconnected every eight channels. A total of 768-channel IC signals are integrated and sampled at a speed of 6 kfps. The MLSIC has a total of 19.2 cm water equivalent thickness and is capable of measurement over a 25 × 25 cm2field size. A reconstruction algorithm is developed to reconstruct 3D dose distribution for each spot at all depths by considering a double-Gaussian-Cauchy-Lorentz model. The 3D dose distribution of each beam is obtained by summing all spots. The performance of our MLSIC is evaluated for a clinical pencil beam scanning (PBS) plan.Main results.The dose distributions for each proton spot can be successfully reconstructed from the ionization current measurement of the strip ICs at different depths, which can be further summed up to a 3D dose distribution for the beam. 3D Gamma Index analysis indicates acceptable agreement between the measured and expected dose distributions from simulation, Zebra and MatriXX.Significance.The dedicated MLSIC is the first pseudo-3D QA device that can measure 3D dose distribution in PBS proton fields spot-by-spot.


Subject(s)
Proton Therapy , Radiometry , Radiometry/instrumentation , Proton Therapy/instrumentation , Radiation Dosage , Radiotherapy Dosage , Protons , Phantoms, Imaging , Humans , Radiotherapy, Intensity-Modulated/instrumentation
5.
Phys Med Biol ; 69(13)2024 Jun 26.
Article in English | MEDLINE | ID: mdl-38862001

ABSTRACT

Objective.To present and characterize a novel method for x-ray computed tomography (xCT) calibration in proton treatment planning, based on proton CT (pCT) measurements on biological phantoms.Approach.A pCT apparatus was used to perform direct measurements of 3D stopping power relative to water (SPR) maps on stabilized, biological phantoms. Two single-energy xCT calibration curves-i.e. tissue substitutes and stoichiometric-were compared to pCT data. Moreover, a new calibration method based on these data was proposed, and verified against intra- and inter-species variability, dependence on stabilization, beam-hardening conditions, and analysis procedures.Main results.Biological phantoms were verified to be stable in time, with a dependence on temperature conditions, especially in the fat region: (-2.5 0.5) HU °C-1. The pCT measurements were compared with standard xCT calibrations, revealing an average SPR discrepancy within ±1.60% for both fat and muscle regions. In the bone region the xCT calibrations overestimated the pCT-measured SPR of the phantom, with a maximum discrepancy of about +3%. As a result, a new cross-calibration curve was directly extracted from the pCT data. Overall, the SPR uncertainty margin associated with this curve was below 3%; fluctuations in the uncertainty values were observed across the HU range. Cross-calibration curves obtained with phantoms made of different animal species and anatomical parts were reproducible with SPR discrepancies within 3%. Moreover, the stabilization procedure did not affect the resulting curve within a 2.2% SPR deviation. Finally, the cross-calibration curve was affected by the beam-hardening conditions on xCTs, especially in the bone region, while dependencies below 2% resulted from the image registration procedure.Significance.Our results showed that pCT measurements on biological phantoms may provide an accurate method for the verification of current xCT calibrations and may represent a tool for the implementation of a new calibration method for proton treatment planning.


Subject(s)
Phantoms, Imaging , Proton Therapy , Radiotherapy Planning, Computer-Assisted , Tomography, X-Ray Computed , Calibration , Proton Therapy/instrumentation , Tomography, X-Ray Computed/instrumentation , Radiotherapy Planning, Computer-Assisted/methods , Protons , Animals , Humans
6.
Phys Med Biol ; 69(13)2024 Jun 28.
Article in English | MEDLINE | ID: mdl-38862000

ABSTRACT

Objective.In proton pencil beam scanning (PBS) continuous delivery, the beam is continuously delivered without interruptions between spots. For synchrotron-based systems, the extracted beam current exhibits a spill structure, and recent publications on beam current measurements have demonstrated significant fluctuations around the nominal values. These fluctuations potentially lead to dose deviations from those calculated assuming a stable beam current. This study investigated the dosimetric implications of such beam current fluctuations during proton PBS continuous scanning.Approach.Using representative clinical proton PBS plans, we performed simulations to mimic a worst-case clinical delivery environment with beam current varies from 50% to 250% of the nominal values. The simulations used the beam delivery parameters optimized for the best beam delivery efficiency of the upcoming particle therapy system at Mayo Clinic Florida. We reconstructed the simulated delivered dose distributions and evaluated the dosimetric impact of beam current fluctuations.Main results.Despite significant beam current fluctuations resulting in deviations at each spot level, the overall dose distributions were nearly identical to those assuming a stable beam current. The 1 mm/1% Gamma passing rate was 100% for all plans. Less than 0.2% root mean square error was observed in the planning target volume dose-volume histogram. Minimal differences were observed in all dosimetric evaluation metrics.Significance.Our findings demonstrate that with our beam delivery system and clinical planning practice, while significant beam current fluctuations may result in large local move monitor unit deviations at each spot level, the overall impact on the dose distribution is minimal.


Subject(s)
Proton Therapy , Radiometry , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Synchrotrons , Proton Therapy/methods , Proton Therapy/instrumentation , Radiometry/instrumentation , Radiometry/methods , Radiotherapy Planning, Computer-Assisted/methods , Humans , Monte Carlo Method
7.
Phys Med Biol ; 69(14)2024 Jul 03.
Article in English | MEDLINE | ID: mdl-38876112

ABSTRACT

Objective. To fabricate and validate a novel focused collimator designed to spare normal tissue in a murine hemithoracic irradiation model using 250 MeV protons delivered at ultra-high dose rates (UHDRs) for preclinical FLASH radiation therapy (FLASH-RT) studies.Approach. A brass collimator was developed to shape 250 MeV UHDR protons from our Varian ProBeam. Six 13 mm apertures, of equivalent size to kV x-ray fields historically used to perform hemithorax irradiations, were precisely machined to match beam divergence, allowing concurrent hemithoracic irradiation of six mice while sparing the contralateral lung and abdominal organs. The collimated field profiles were characterized by film dosimetry, and a radiation survey of neutron activation was performed to ensure the safety of staff positioning animals.Main results. The brass collimator produced 1.2 mm penumbrae radiation fields comparable to kV x-rays used in preclinical studies. The penumbrae in the six apertures are similar, with full-width half-maxima of 13.3 mm and 13.5 mm for the central and peripheral apertures, respectively. The collimator delivered a similar dose at an average rate of 52 Gy s-1for all apertures. While neutron activation produces a high (0.2 mSv h-1) initial ambient equivalent dose rate, a parallel work-flow in which imaging and setup are performed without the collimator ensures safety to staff.Significance. Scanned protons have the greatest potential for future translation of FLASH-RT in clinical treatments due to their ability to treat deep-seated tumors with high conformality. However, the Gaussian distribution of dose in proton spots produces wider lateral penumbrae compared to other modalities. This presents a challenge in small animal pre-clinical studies, where millimeter-scale penumbrae are required to precisely target the intended volume. Offering high-throughput irradiation of mice with sharp penumbrae, our novel collimator-based platform serves as an important benchmark for enabling large-scale, cost-effective radiobiological studies of the FLASH effect in murine models.


Subject(s)
Proton Therapy , Animals , Mice , Proton Therapy/instrumentation , Proton Therapy/methods , Organs at Risk/radiation effects , Radiotherapy Dosage
8.
In Vivo ; 38(4): 2080-2084, 2024.
Article in English | MEDLINE | ID: mdl-38936928

ABSTRACT

BACKGROUND/AIM: We report on a case of locally advanced hepatocellular carcinoma (HCC) accompanied by an inferior vena cava tumor thrombus (IVCTT), treated successfully with proton-beam therapy (PBT). CASE REPORT: A 63-year-old male presented with a primary, single HCC with IVCTT, without metastasis to the intrahepatic region, lymph nodes, or distant organs. The clinical staging was identified as T4N0M0 Stage IIIB. The patient's liver function was classified as Child-Pugh class A (score: 6), with a modified albumin-bilirubin (mALBI) grade of 2a. The patient had liver cirrhosis due to non-alcoholic steatohepatitis. Magnetic resonance imaging revealed a nodular tumor measuring 13.2×8.9×9.8 cm across segments 1, 6, 7, and 8, along with IVCTT. The patient received PBT, with a total dose of 72.6 Gy (relative biological effectiveness) delivered in 22 fractions. Throughout the PBT treatment, the patient experienced no acute toxicities and completed the therapy as planned. Twelve months following PBT, the patient was alive without evidence of local recurrence, lymph node involvement, or distant organ metastasis. The only late toxicity observed was a mild worsening of the mALBI grade. CONCLUSION: We observed a favorable local response with manageable toxicities in a patient with locally advanced HCC and IVCTT treated with PBT. While this is a single case report, our findings suggest that PBT could be considered a viable treatment option for HCC with IVCTT.


Subject(s)
Carcinoma, Hepatocellular , Liver Neoplasms , Proton Therapy , Vena Cava, Inferior , Humans , Male , Liver Neoplasms/radiotherapy , Liver Neoplasms/pathology , Liver Neoplasms/therapy , Carcinoma, Hepatocellular/radiotherapy , Carcinoma, Hepatocellular/pathology , Carcinoma, Hepatocellular/therapy , Carcinoma, Hepatocellular/complications , Middle Aged , Vena Cava, Inferior/pathology , Vena Cava, Inferior/diagnostic imaging , Treatment Outcome , Magnetic Resonance Imaging , Neoplasm Staging , Venous Thrombosis/etiology , Venous Thrombosis/pathology , Venous Thrombosis/radiotherapy , Venous Thrombosis/therapy
9.
Technol Cancer Res Treat ; 23: 15330338241252622, 2024.
Article in English | MEDLINE | ID: mdl-38845139

ABSTRACT

Purpose: The aim of this matched-pair cohort study was to evaluate the potential of intensity-modulated proton therapy (IMPT) for sparring of the pelvic bone marrow and thus reduction of hematotoxicity compared to intensity-modulated photon radiotherapy (IMRT) in the setting of postoperative irradiation of gynaecological malignancies. Secondary endpoint was the assessment of predictive parameters for the occurrence of sacral insufficiency fractures (SIF) when applying IMPT. Materials and Methods: Two cohorts were analyzed consisting of 25 patients each. Patients were treated with IMPT compared with IMRT and had uterine cervical (n = 8) or endometrial cancer (n = 17). Dose prescription, patient age, and diagnosis were matched. Dosimetric parameters delivered to the whole pelvic skeleton and subsites (ilium, lumbosacral, sacral, and lower pelvis) and hematological toxicity were evaluated. MRI follow-up for evaluation of SIF was only available for the IMPT group. Results: In the IMPT group, integral dose to the pelvic skeleton was significantly lower (23.4GyRBE vs 34.3Gy; p < 0.001), the average V5Gy, V10Gy, and V20Gy were reduced by 40%, 41%, and 28%, respectively, compared to the IMRT group (p < 0.001). In particular, for subsites ilium and lower pelvis, the low dose volume was significantly lower. Hematotoxicity was significantly more common in the IMRT group (80% vs 32%; p = 0009), especially hematotoxicity ≥ CTCAE II (36% vs 8%; p = 0.037). No patient in the IMPT group experienced hematotoxicity > CTCAE II. In the IMPT cohort, 32% of patients experienced SIF. Overall SIF occurred more frequently with a total dose of 50.4 GyRBE (37.5%) compared to 45 GyRBE (22%). No significant predictive dose parameters regarding SIF could be detected aside from a trend regarding V50Gy to the lumbosacral subsite. Conclusion: Low-dose exposure to the pelvic skeleton and thus hematotoxicity can be significantly reduced by using IMPT compared to a matched photon cohort. Sacral insufficiency fracture rates appear similar to reported rates for IMRT in the literature.


Subject(s)
Bone Marrow , Genital Neoplasms, Female , Proton Therapy , Radiotherapy Dosage , Radiotherapy, Intensity-Modulated , Humans , Female , Radiotherapy, Intensity-Modulated/adverse effects , Radiotherapy, Intensity-Modulated/methods , Proton Therapy/adverse effects , Proton Therapy/methods , Bone Marrow/radiation effects , Bone Marrow/pathology , Middle Aged , Aged , Genital Neoplasms, Female/radiotherapy , Adult , Radiotherapy Planning, Computer-Assisted , Organs at Risk/radiation effects , Organ Sparing Treatments/methods
10.
Semin Radiat Oncol ; 34(3): 292-301, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38880538

ABSTRACT

Spatially-fractionated radiotherapy (SFRT) delivers high doses to small areas of tumor while sparing adjacent tissue, including intervening disease. In this review, we explore the evolution of SFRT technological advances, contrasting approaches with photon and proton beam radiotherapy. We discuss unique dosimetric considerations and physical properties of SFRT, as well as review the preclinical literature that provides an emerging understanding of biological mechanisms. We emphasize crucial areas of future study and highlight clinical trials that are underway to assess SFRT's safety and efficacy, with a focus on immunotherapeutic synergies. The review concludes with practical considerations for SFRT's clinical application, advocating for strategies that leverage its unique dosimetric and biological properties for improved patient outcomes.


Subject(s)
Dose Fractionation, Radiation , Neoplasms , Photons , Proton Therapy , Humans , Proton Therapy/methods , Photons/therapeutic use , Neoplasms/radiotherapy
11.
BMC Cancer ; 24(1): 742, 2024 Jun 18.
Article in English | MEDLINE | ID: mdl-38890585

ABSTRACT

BACKGROUND: Nasopharyngeal adenoid cystic carcinoma (NACC) is a relatively rare salivary gland tumor that is generally associated with poor outcomes. High-dose radiotherapy is a key treatment for patients with NACC. This study reported the long-term efficacy and safety of particle beam radiation therapy (PBRT) for NACC. METHODS AND MATERIALS: Twenty-six patients with nonmetastatic NACC who received definitive PBRT alone were included in this retrospective study. The majority of patients (92.3%) had locally advanced disease. Twenty-five (96.15%) patients received intensity-modulated proton radiotherapy (IMPT) followed by a carbon ion radiotherapy (CIRT) boost, and one patient received CIRT alone. Overall survival (OS), local control (LC), regional control (RC), and distant metastasis control (DMC) rates were calculated via the Kaplan-Meier method. RESULTS: The median follow-up time was 46.95 months for the entire cohort. Seven patients experienced local recurrence, and one patient experience neck lymph node recurrence. The 3- and 4-year OS, LC, RC, and DMC rates were 100% and 91.7%, 92.3% and 84.6%, 95.8% and 87.8%, and 90.2% and 71.3%, respectively. A total of 91.3% of the patients achieved complete remission of gross tumors at 1 year after PBRT. Severe acute toxicity was observed in only two patients. A grade 4 decrease in visual acuity was observed in one patient with orbital apex invasion. No late grade 3 or 5 toxicity was observed. CONCLUSION: Definitive PBRT provided a satisfactory 4-year OS for patients with locally advanced NACC. The toxicity was acceptable and mild. Further follow-up is necessary to confirm the efficacy and safety of definitive PBRT for patients with NACC.


Subject(s)
Carcinoma, Adenoid Cystic , Nasopharyngeal Neoplasms , Proton Therapy , Humans , Carcinoma, Adenoid Cystic/radiotherapy , Carcinoma, Adenoid Cystic/mortality , Carcinoma, Adenoid Cystic/pathology , Male , Female , Middle Aged , Nasopharyngeal Neoplasms/radiotherapy , Nasopharyngeal Neoplasms/mortality , Nasopharyngeal Neoplasms/pathology , Adult , Retrospective Studies , Treatment Outcome , Aged , Proton Therapy/adverse effects , Proton Therapy/methods , Radiotherapy, Intensity-Modulated/adverse effects , Radiotherapy, Intensity-Modulated/methods , Young Adult , Follow-Up Studies , Nasopharyngeal Carcinoma/radiotherapy , Nasopharyngeal Carcinoma/mortality , Nasopharyngeal Carcinoma/pathology , Neoplasm Recurrence, Local/radiotherapy , Heavy Ion Radiotherapy/adverse effects , Heavy Ion Radiotherapy/methods
12.
Zhongguo Yi Liao Qi Xie Za Zhi ; 48(3): 271-276, 2024 May 30.
Article in Chinese | MEDLINE | ID: mdl-38863092

ABSTRACT

In order to improve the biological effect of proton therapy, the authors first propose a new method of boron-based proton-enhanced radiotherapy in a " ternary " radiotherapy mode, based on the existing sensitizing effect of proton radiotherapy: i.e, Boron-based mediators (11B and 10B) induce the proton-hydrogen-boron fusion reaction of the low-energy protons arriving at the Bragg peak region of the tumor target area (p+11B→3α) and thermal neutron capture (10B+n→7Li3+(0.84 MeV)+4He2+(1.47 MeV)+γ(0.477 MeV)), which release low-energy α-particles with high LETs to enhance the biological effect of proton dose in the target area, thus improve the clinical effect of proton therapy. Then, the advantages and disadvantages of the "ternary" model were analyzed from the theoretical basis and current research status, and finally, the "ternary" model is summarized and prospected.


Subject(s)
Proton Therapy , Protons , Boron , Neoplasms/radiotherapy , Radiotherapy Dosage , Alpha Particles/therapeutic use , Models, Theoretical
13.
Oral Oncol ; 154: 106875, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38824813

ABSTRACT

INTRODUCTION: Re-irradiation (re-RT) for recurrent head and neck cancer (rHNC) is challenging. We describe clinical outcomes and toxicity of proton therapy (PT) for recurrent HNC, and report genomic alterations associated with patterns of failure. MATERIALS & METHODS: We performed a retrospective analysis of rHNC patients treated with PT. Outcomes were estimated using the Kaplan-Meier method. Univariate (UVA) and multivariate analyses (MVA) were performed to assess multiple patient factors. Next-generation sequencing and genomic analyses were performed on available samples. RESULTS: Eighty-nine patients treated with PBS-PT for rHNC with a median follow-up of 12 mo (0-71 mo) were included. The 1- and 2-y local control (LC) rates were 80.8 % (95 % CI: 70.8-90.8) and 66.2 % (95 % CI: 50.7-81.7), and 1- and 2-y distant metastasis-free survival (DMFS) were 41.0 % (95 % CI: 30.0-52.0) and 26.3 % (95 % CI: 15.7-36.9). The median overall survival (OS) was 13 mo (95 % CI: 9.3-16.7). On UVA and MVA, smaller gross tumor volume (GTV) was associated with improved OS (HR 1.002, P = 0.004), DMFS (HR 1.002, P = 0.004), and PFS (HR 1.002, P = 0.014). There were 35 late Gr3 + toxicity events (30.3 %). Patients with higher candidate gene-specific mutation burden (genes with [OR] > 2, P < 0.05) had inferior PFS. TP53, NOTCH4, and ARID1B mutations were associated with inferior DMFS (OR > 2, P < 0.05). CONCLUSIONS: PBS-PT is effective at achieving LC for rHNC with favorable toxicity. Distant metastases are common, and associated with TP53, NOTCH4, and ARID1B mutations. Inclusion of genomic alterations in the clinical decision process may be warranted.


Subject(s)
Head and Neck Neoplasms , Neoplasm Recurrence, Local , Proton Therapy , Humans , Female , Male , Middle Aged , Proton Therapy/methods , Proton Therapy/adverse effects , Aged , Head and Neck Neoplasms/radiotherapy , Head and Neck Neoplasms/genetics , Adult , Neoplasm Recurrence, Local/genetics , Neoplasm Recurrence, Local/radiotherapy , Retrospective Studies , Aged, 80 and over , Re-Irradiation/methods , Treatment Outcome , Genomics/methods , Mutation
14.
Support Care Cancer ; 32(7): 442, 2024 Jun 18.
Article in English | MEDLINE | ID: mdl-38890189

ABSTRACT

PURPOSE: The aim of this study was to explore patients' experience of participation in the treatment decision of proton beam therapy versus conventional radiotherapy. BACKGROUND: Proton beam therapy (PBT) has become a treatment option for some cancer patients receiving radiotherapy. The decision to give PBT instead of conventional radiotherapy (CRT) needs to be carefully planned together with the patient to ensure that the degree of participation is based on individuals' preferences. There is a knowledge gap of successful approaches to support patients' participation in the decision-making process, which is particularly important when it comes to the situation of having to choose between two treatment options such as PBT and CRT, with similar expected outcomes. METHOD: We conducted a secondary analysis of qualitative data collected from interviews with patients who received PBT for their brain tumor. Transcribed verbatims from interviews with 22 patients were analyzed regarding experiences of participation in the decision-making process leading to PBT. FINDINGS: Participants experienced their participation in the decision-making process to a varying degree, and with individual preferences. Four themes emerged from data: to be a voice that matters, to get control over what will happen, being in the hand of doctors' choice, and feeling selected for treatment. CONCLUSION: A decision for treatment with PBT can be experienced as a privilege but can also cause stress as it might entail practical issues affecting everyday life in a considerable way. For the patient to have confidence in the decision-making process, patients' preferences, expectations, and experiences must be included by the healthcare team. Including the patient in the healthcare team as an equal partner by confirming the person enables and facilitates for patients' voice to be heard and reckoned with. Person-centered care building on a partnership between patients and healthcare professionals should provide the right basis for the decision-making process.


Subject(s)
Brain Neoplasms , Decision Making , Patient Participation , Proton Therapy , Qualitative Research , Humans , Female , Male , Proton Therapy/methods , Middle Aged , Aged , Brain Neoplasms/radiotherapy , Brain Neoplasms/psychology , Adult , Aged, 80 and over , Patient Preference , Interviews as Topic , Patient Care Team/organization & administration
15.
Radiat Oncol ; 19(1): 75, 2024 Jun 17.
Article in English | MEDLINE | ID: mdl-38886727

ABSTRACT

BACKGROUND AND PURPOSE: Rare but severe toxicities of the optic apparatus have been observed after treatment of intracranial tumours with proton therapy. Some adverse events have occurred at unusually low dose levels and are thus difficult to understand considering dose metrics only. When transitioning from double scattering to pencil beam scanning, little consideration was given to increased dose rates observed with the latter delivery paradigm. We explored if dose rate related metrics could provide additional predicting factors for the development of late visual toxicities. MATERIALS AND METHODS: Radiation-induced intracranial visual pathway lesions were delineated on MRI for all index cases. Voxel-wise maximum dose rate (MDR) was calculated for 2 patients with observed optic nerve toxicities (CTCAE grade 3 and 4), and 6 similar control cases. Additionally, linear energy transfer (LET) related dose enhancing metrics were investigated. RESULTS: For the index cases, which developed toxicities at low dose levels (mean, 50 GyRBE), some dose was delivered at higher instantaneous dose rates. While optic structures of non-toxicity cases were exposed to dose rates of up to 1 to 3.2 GyRBE/s, the pre-chiasmatic optic nerves of the 2 toxicity cases were exposed to dose rates above 3.7 GyRBE/s. LET-related metrics were not substantially different between the index and non-toxicity cases. CONCLUSIONS: Our observations reveal large variations in instantaneous dose rates experienced by different volumes within our patient cohort, even when considering the same indications and beam arrangement. High dose rate regions are spatially overlapping with the radiation induced toxicity areas in the follow up images. At this point, it is not feasible to establish causality between exposure to high dose rates and the development of late optic apparatus toxicities due to the low incidence of injury.


Subject(s)
Brain Neoplasms , Proton Therapy , Radiation Injuries , Radiotherapy Dosage , Humans , Proton Therapy/adverse effects , Proton Therapy/methods , Brain Neoplasms/radiotherapy , Female , Male , Middle Aged , Adult , Radiation Injuries/etiology , Aged , Optic Nerve/radiation effects , Organs at Risk/radiation effects , Radiotherapy Planning, Computer-Assisted/methods , Dose-Response Relationship, Radiation
16.
Phys Med Biol ; 69(13)2024 Jun 27.
Article in English | MEDLINE | ID: mdl-38870996

ABSTRACT

Objective. To quantitatively investigate the impact of spot position error (PE) on the dose distribution in (Spot-scanning arc therapy) SPArc plans compared to Intensity-Modulated Proton Therapy (IMPT).Approach.Twelve representative cases, including brain, lung, liver, and prostate cancers, were retrospectively selected. Spot PEs were simulated during dynamic SPArc treatment delivery. Two types of errors were generated, including random error and systematic error. Two different probability distributions of random errors were used (1) Gaussian distribution (PEran-GS) (2) uniform distribution (PEran-UN). In PEran-UN, four sub-scenarios were considered: 25%, 50%, 75%, and 100% spots were randomly selected in various directions on the scale of 0-1 mm or 0-2 mm of PE. Additionally, systematic error was simulated by shifting all the spot uniformly by 1 or 2 mm in various directions (PEsys). Gamma-index Passing Rate (GPR) is applied to assess the dosimetric perturbation quantitatively.Main results.For PEran-GSin the 1 mm scenario, both SPArc and IMPT are comparable with a GPR exceeding 99%. However, for PEran-GSin 2 mm scenario, SPArc could provide better GPR. As PEsysof 2 mm, SPArc plans have a much better GPR compared to IMPT plans: SPArc's GPR is 99.59 ± 0.47%, 93.82 ± 4.07% and 64.58 ± 15.83% for 3 mm/3%, 2 mm/2% and 1 mm/1% criteria compared to IMPT with 97.49 ± 2.44%, 84.59 ± 4.99% and 42.02 ± 6.31%.Significance.Compared to IMPT, SPArc shows better dosimetric robustness in spot PEs. This study presents the first simulation results and the methodology that serves as a reference to guide future investigations into the accuracy and quality assurance of SPArc treatment delivery.


Subject(s)
Radiometry , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated , Humans , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Neoplasms/radiotherapy , Proton Therapy/methods
19.
Anticancer Res ; 44(7): 2973-2979, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38925851

ABSTRACT

BACKGROUND/AIM: Pre-clinical studies have shown that irradiation with electrons at an ultra-high dose-rate (FLASH) spares normal tissue while maintaining tumor control. However, most in vitro experiments with protons have been conducted using a non-clinical irradiation system in normoxia alone. This study evaluated the biological response of non-tumor and tumor cells at different oxygen concentrations irradiated with ultra-high dose-rate protons using a clinical system and compared it with the conventional dose rate (CONV). MATERIALS AND METHODS: Non-tumor cells (V79) and tumor cells (U-251 and A549) were irradiated with 230 MeV protons at a dose rate of >50 Gy/s or 0.1 Gy/s under normoxic or hypoxic (<2%) conditions. The surviving fraction was analyzed using a clonogenic cell survival assay. RESULTS: No significant difference in the survival of non-tumor or tumor cells irradiated with FLASH was observed under normoxia or hypoxia compared to the CONV. CONCLUSION: Proton irradiation at a dose rate above 40 Gy/s, the FLASH dose rate, did not induce a sparing effect on either non-tumor or tumor cells under the conditions examined. Further studies are required on the influence of various factors on cell survival after FLASH irradiation.


Subject(s)
Cell Survival , Proton Therapy , Protons , Humans , Cell Survival/radiation effects , Dose-Response Relationship, Radiation , Cell Hypoxia/radiation effects , Animals , Cell Line, Tumor , Cricetulus , A549 Cells , Oxygen/metabolism
20.
Neurosurg Focus ; 56(5): E9, 2024 05.
Article in English | MEDLINE | ID: mdl-38691864

ABSTRACT

OBJECTIVE: Chordomas are rare tumors of the skull base and spine believed to arise from the vestiges of the embryonic notochord. These tumors are locally aggressive and frequently recur following resection and adjuvant radiotherapy. Proton therapy has been introduced as a tissue-sparing option because of the higher level of precision that proton-beam techniques offer compared with traditional photon radiotherapy. This study aimed to compare recurrence in patients with chordomas receiving proton versus photon radiotherapy following resection by applying tree-based machine learning models. METHODS: The clinical records of all patients treated with resection followed by adjuvant proton or photon radiotherapy for chordoma at Mayo Clinic were reviewed. Patient demographics, type of surgery and radiotherapy, tumor recurrence, and other variables were extracted. Decision tree classifiers were trained and tested to predict long-term recurrence based on unseen data using an 80/20 split. RESULTS: Fifty-three patients with a mean ± SD age of 55.2 ± 13.4 years receiving surgery and adjuvant proton or photon therapy to treat chordoma were identified; most patients were male. Gross-total resection was achieved in 54.7% of cases. Proton therapy was the most common adjuvant radiotherapy (84.9%), followed by conventional or external-beam radiation therapy (9.4%) and stereotactic radiosurgery (5.7%). Patients receiving proton therapy exhibited a 40% likelihood of having recurrence, significantly lower than the 88% likelihood observed in those treated with nonproton therapy. This was confirmed on logistic regression analysis adjusted for extent of tumor resection and tumor location, which revealed that proton adjuvant radiotherapy was associated with a decreased risk of recurrence (OR 0.1, 95% CI 0.01-0.71; p = 0.047) compared with photon therapy. The decision tree algorithm predicted recurrence with an accuracy of 90% (95% CI 55.5%-99.8%), with the lowest risk of recurrence observed in patients receiving gross-total resection with adjuvant proton therapy (23%). CONCLUSIONS: Following resection, adjuvant proton therapy was associated with a lower risk of chordoma recurrence compared with photon therapy. The described machine learning models were able to predict tumor progression based on the extent of tumor resection and adjuvant radiotherapy modality used.


Subject(s)
Chordoma , Neoplasm Recurrence, Local , Photons , Proton Therapy , Spinal Neoplasms , Humans , Chordoma/radiotherapy , Chordoma/surgery , Male , Female , Middle Aged , Neoplasm Recurrence, Local/radiotherapy , Proton Therapy/methods , Radiotherapy, Adjuvant/methods , Adult , Aged , Spinal Neoplasms/radiotherapy , Spinal Neoplasms/surgery , Photons/therapeutic use , Retrospective Studies , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...