Results 1 - 20 de 688
Filter
1.
Igaku Butsuri ; 44(2): 21-28, 2024.
Article in Japanese | MEDLINE | ID: mdl-38945879

ABSTRACT

BACKGROUND: A new quality assurance and control method for electrometers using a new current source, different from the method published in the guidelines for electrometers, has been reported. This current source uses dry batteries and exhibits excellent performance in terms of voltage, temperature, and time characteristics. The electrometer sensitivity coefficient can be calculated by comparing the sensitivity of one electrometer with that of another on the electrometer calibration coefficient that has been calibrated by a calibration laboratory in advance in both methods. The guideline method requires two or more sets of ionization chambers and electrometers in the facility. In contrast, our method does not use ionization chambers; therefore, the sensitivity ratio of the electrometer can be measured in any facility. This study compared the uncertainty of the electrometer sensitivity factor calculated using the new current source method (current method) with that calculated using a linear accelerator (LINAC) and ionization chambers (LINAC method) described in the electrometer guidelines. METHOD: In this study, we used a current source that we invented previously by Kawaguchi Electric Works in Japan. The sensitivity ratios of the electrometers were measured with three manufacture's electrometers. The electrometer sensitivity factor was calculated by multiplying the electrometer calibration coefficient. The ionization chamber was 30013 (PTW), and the current source was the current obtained from 10 MV TrueBeam X-rays under calibration conditions. The mean value, standard deviation, and coefficient of variation were calculated. The time required to set up the ionization chamber for calculating the sensitivity ratio of the electrometer was also measured. The accuracy was confirmed by calculating the expanded uncertainty of the electrometer sensitivity coefficients. RESULTS: The LINAC method had a maximum coefficient of variation of 0.072%. The gross time of the LINAC method was approximately 110 min. The current method had a maximum coefficient of variation of 0.0055% and took less than half the time taken by the LINAC method (35 min) because there was no waiting time for the ionization chamber to be set up and the applied voltage to stabilize under calibration conditions. The expanded uncertainties of the electrometer calibration coefficients were 0.36% and 0.36%, respectively. CONCLUSION: The new cross-comparison method for electrometer sensitivity factors using a current source is more efficient and useful than the linear accelerator method described in the guidelines; furthermore, this method ensured accuracy for quality assurance and control of electrometers.


Subject(s)
Radiation Dosimeters , Uncertainty , Calibration , Guidelines as Topic , Radiometry/instrumentation , Radiometry/methods , Particle Accelerators
2.
Molecules ; 29(11)2024 May 29.
Article in English | MEDLINE | ID: mdl-38893435

ABSTRACT

This work describes the development of a reusable 2D detector based on radiochromic reaction for radiotherapy dosimetric measurements. It consists of a radiochromic gel dosimeter in a cuboidal plastic container, scanning with a flatbed scanner, and data processing using a dedicated software package. This tool is assessed using the example of the application of the coincidence test of radiation and mechanical isocenters for a medical accelerator. The following were examined: scanning repeatability and image homogeneity, the impact of image processing on data processing in coincidence tests, and irradiation conditions-monitor units per radiation beam and irradiation field are selected. Optimal conditions for carrying out the test are chosen: (i) the multi-leaf collimator gap should preferably be 5 mm for 2D star shot irradiation, (ii) it is recommended to apply ≥2500-≤5000 MU per beam to obtain a strong signal enabling easy data processing, (iii) Mean filter can be applied to the images to improve calculations. An approach to dosimeter reuse with the goal of reducing costs is presented; the number of reuses is related to the MUs per beam, which, in this study, is about 5-57 for 30,000-2500 MU per beam (four fields). The proposed reusable system was successfully applied to the coincidence tests, confirming its suitability as a new potential quality assurance tool in radiotherapy.


Subject(s)
Radiation, Ionizing , Radiometry/methods , Radiometry/instrumentation , Gels/chemistry , Radiotherapy/methods , Radiotherapy Dosage , Radiation Dosimeters , Particle Accelerators
3.
Radiat Prot Dosimetry ; 200(10): 890-900, 2024 Jun 22.
Article in English | MEDLINE | ID: mdl-38847419

ABSTRACT

The metrological quality of a measurement is characterised by evaluating the uncertainty in the measurement. In this paper, uncertainty in personal dose measured using individual monitoring CaSO4:Dy-based thermoluminescence dosimeter badge is evaluated by application of the guide to the expression of uncertainty in measurement method. The present dose reporting quantity, whole body dose (WBD) and the proposed quantity, personal dose equivalent, Hp(10) has been used as measurands. The influence of various input quantities on the measurement were analyzed through tests that conform to the requirements of the International Electrotechnical Commission IEC 62387. The study found that the expanded uncertainties for WBD and Hp(10) measurements were 63.4% and 41.4%, respectively, corresponding to a 95% coverage probability for workplace fields covering a wide photon energy range (33-1250 keV). However, the uncertainty estimates were quite lower for the type of workplaces that are identified using the dose evaluation algorithm. The input quantities, namely, the response to a mixture of photon beam qualities and photon energy and angular dependence contribute the most to the total uncertainty.


Subject(s)
Occupational Exposure , Radiation Dosage , Thermoluminescent Dosimetry , Workplace , Thermoluminescent Dosimetry/instrumentation , Thermoluminescent Dosimetry/methods , Humans , Occupational Exposure/analysis , Uncertainty , Radiation Monitoring/methods , Algorithms , Dysprosium/chemistry , Photons , Radiation Protection/methods , Radiation Protection/standards , Radiation Dosimeters
4.
J Appl Clin Med Phys ; 25(6): e14387, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38778567

ABSTRACT

INTRODUCTION: Radiation dose measurement is an essential part of radiotherapy to verify the correct delivery of doses to patients and ensure patient safety. Recent advancements in radiotherapy technology have highlighted the need for fast and precise dosimeters. Technologies like FLASH radiotherapy and magnetic-resonance linear accelerators (MR-LINAC) demand dosimeters that can meet their unique requirements. One promising solution is the plastic scintillator-based dosimeter with high spatial resolution and real-time dose output. This study explores the feasibility of using the LuSy dosimeter, an in-house developed plastic scintillator dosimeter for dose verification across various radiotherapy techniques, including conformal radiotherapy (CRT), intensity-modulated radiation therapy (IMRT), volumetric-modulated arc therapy (VMAT), and stereotactic radiosurgery (SRS). MATERIALS AND METHODS: A new dosimetry system, comprising a new plastic scintillator as the sensing material, was developed and characterized for radiotherapy beams. Treatment plans were created for conformal radiotherapy, IMRT, VMAT, and SRS and delivered to a phantom. LuSy dosimeter was used to measure the delivered dose for each plan on the surface of the phantom and inside the target volumes. Then, LuSy measurements were compared against an ionization chamber, MOSFET dosimeter, radiochromic films, and dose calculated using the treatment planning system (TPS). RESULTS: For CRT, surface dose measurement by LuSy dosimeter showed a deviation of -5.5% and -5.4% for breast and abdomen treatment from the TPS, respectively. When measuring inside the target volume for IMRT, VMAT, and SRS, the LuSy dosimeter produced a mean deviation of -3.0% from the TPS. Surface dose measurement resulted in higher TPS discrepancies where the deviations for IMRT, VMAT, and SRS were -2.0%, -19.5%, and 16.1%, respectively. CONCLUSION: The LuSy dosimeter was feasible for measuring radiotherapy doses for various treatment techniques. Treatment delivery verification enables early error detection, allowing for safe treatment delivery for radiotherapy patients.


Subject(s)
Feasibility Studies , Particle Accelerators , Phantoms, Imaging , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated , Humans , Radiotherapy, Intensity-Modulated/methods , Radiotherapy Planning, Computer-Assisted/methods , Particle Accelerators/instrumentation , Radiosurgery/methods , Radiation Dosimeters , Radiotherapy, Conformal/methods , Radiotherapy, Conformal/instrumentation , Radiometry/methods , Radiometry/instrumentation , Organs at Risk/radiation effects , Neoplasms/radiotherapy
5.
Appl Radiat Isot ; 210: 111371, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38815447

ABSTRACT

This work builds upon a prior study, examining the dosimetric utility of pencil lead and thin graphitic sheets, focusing upon the measurement of skin doses within the mammographic regime. In recognizing the near soft-tissue equivalence of graphite and the earlier-observed favourable thermoluminescence yield of thin sheets of graphite, this has led to present study of 50 µm thick graphite for parameters typical of external beam fractionated radiotherapy and skin dose evaluations. The graphite layers were annealed and then stacked to form an assembly of 0.5 mm nominal thickness. Using a 6 MV photon beam and delivering doses from 2- to 60 Gy, irradiations were conducted, the assembly first forming a superficial layer to a solid water phantom and subsequently underlying a 1.5 cm bolus, seeking to circumvent the build-up to electronic equilibrium for skin treatments. Investigations were made of several dosimetric properties arising from the thermoluminescence yield of the 50 µm thick graphite slabs, in particular proportionality and sensitivity to dose. The results show excellent sensitivity within the dose range of interest, the thermoluminescence response varying with increasing depth through the stacked graphite layers, obtaining a coefficient of determination of 90%. Acknowledging there to be considerable challenge in accurately matching skin thickness with dose, the graphite sheets have nevertheless shown considerable promise as dosimeters of skin, sensitive in determination of dose from the surface of the graphite through to sub-dermal depth thicknesses.


Subject(s)
Graphite , Photons , Skin , Graphite/chemistry , Skin/radiation effects , Humans , Radiation Dosimeters , Phantoms, Imaging , Radiotherapy Dosage , Thermoluminescent Dosimetry/methods , Equipment Design
6.
Biomed Phys Eng Express ; 10(4)2024 May 15.
Article in English | MEDLINE | ID: mdl-38701767

ABSTRACT

Thermoluminescent dosimeters (TLDs) serve as compact and user-friendly tools for various applications, including personal radiation dosimetry and radiation therapy. This study explores the potential of utilizing TLD-100 personal dosimetry, conventionally applied in PET/CT (positron emission tomography/computed tomography) settings, in the PET/MRI (magnetic resonance imaging) environment. The integration of MRI into conventional radiotherapy and PET systems necessitates ionizing radiation dosimetry in the presence of static magnetic fields. In this study, TLD-100 dosimeters were exposed on the surface of a water-filled cylindrical phantom containing PET-radioisotope and positioned on the patient table of a 3 T PET/MRI, where the magnetic field strength is around 0.2 T, aiming to replicate real-world scenarios experienced by personnel in PET/MRI environments. Results indicate that the modified MR-safe TLD-100 personal dosimeters exhibit no significant impact from the static magnetic field of the 3 T PET/MRI, supporting their suitability for personal dosimetry in PET/MRI settings. This study addresses a notable gap in existing literature on the effect of MRI static magnetic field on TLDs.


Subject(s)
Magnetic Resonance Imaging , Occupational Exposure , Phantoms, Imaging , Thermoluminescent Dosimetry , Thermoluminescent Dosimetry/methods , Humans , Magnetic Resonance Imaging/methods , Occupational Exposure/analysis , Occupational Exposure/prevention & control , Positron Emission Tomography Computed Tomography/methods , Radiation Dosage , Positron-Emission Tomography/methods , Radiation Monitoring/methods , Magnetic Fields , Radiation Dosimeters
7.
Phys Med ; 121: 103360, 2024 May.
Article in English | MEDLINE | ID: mdl-38692114

ABSTRACT

This paper reports the development of dosimeters based on plastic scintillating fibers imaged by a charge-coupled device camera, and their performance evaluation through irradiations with the electron Flash research accelerator located at the Centro Pisano Flash Radiotherapy. The dosimeter prototypes were composed of a piece of plastic scintillating fiber optically coupled to a clear optical fiber which transported the scintillation signal to the readout systems (an imaging system and a photodiode). The following properties were tested: linearity, capability to reconstruct the percentage depth dose curve in solid water and to sample in time the single beam pulse. The stem effect contribution was evaluated with three methods, and a proof-of-concept one-dimensional array was developed and tested for online beam profiling. Results show linearity up to 10 Gy per pulse, and good capability to reconstruct both the timing and spatial profiles of the beam, thus suggesting that plastic scintillating fibers may be good candidates for low-energy electron Flash dosimetry.


Subject(s)
Electrons , Plastics , Radiation Dosimeters , Radiotherapy Dosage , Scintillation Counting , Electrons/therapeutic use , Scintillation Counting/instrumentation , Radiometry/instrumentation
8.
Appl Radiat Isot ; 208: 111307, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38564840

ABSTRACT

Early works that used thermoluminescent dosimeters (TLDs) to measure absorbed dose from alpha particles reported relatively high variation (10%) between TLDs, which is undesirable for modern dosimetry applications. This work outlines a method to increase precision for absorbed dose measured using TLDs with alpha-emitting radionuclides by applying an alpha-specific chip factor (CF) that individually characterizes the TLD sensitivity to alpha particles. Variation between TLDs was reduced from 21.8% to 6.7% for the standard TLD chips and 7.9% to 3.3% for the thin TLD chips. It has been demonstrated by this work that TLD-100 can be calibrated to precisely measure the absorbed dose to water from alpha-emitting radionuclides.


Subject(s)
Radiation Dosimeters , Thermoluminescent Dosimetry , Thermoluminescent Dosimetry/methods , Radioisotopes , Radiometry/methods , Calibration
9.
Appl Radiat Isot ; 209: 111323, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38631246

ABSTRACT

This work investigates the feasibility of yeast-based impedance measurements for retrospective dosimetry applications. The local environment around yeast cells in a previously developed film-badge was modeled using Geant4. A greater dose response was observed when yeast cells were surrounded by an aluminum-polymer structure, which acted as a conversion layer. Bench-top experiments were conducted using a jar-based dosimeter design that directly combined a finely-ground aluminum conversion medium with yeast powder. It was shown when irradiated in the presence of aluminum grains, yeast cells yielded a higher impedance signal, thereby indicating greater radiation-induced damage. Finally, in separate irradiation experiments, lead and aluminum sheets were placed behind yeast samples and the dosimeters were irradiated to 1 Gy. A 2-fold increase in the impedance signal was shown when samples were positioned in close contact with the lead sheet compared to the aluminum sheet. In all experiments, it was shown that the local environment significantly influences radiative energy deposition in yeast cells.


Subject(s)
Electric Impedance , Saccharomyces cerevisiae , Saccharomyces cerevisiae/radiation effects , Aluminum/chemistry , Radiometry/methods , Radiometry/instrumentation , Radiation Dosage , Radiation Dosimeters
10.
Biosens Bioelectron ; 255: 116237, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38537429

ABSTRACT

Scintillation-based fiber dosimeters are a powerful tool for minimally invasive localized real-time monitoring of the dose rate during Low Dose Rate (LDR) and High Dose Rate (HDR) brachytherapy (BT). This paper presents the design, fabrication, and characterization of such dosimeters, consisting of scintillating sensor tips attached to polymer optical fiber (POF). The sensor tips consist of inorganic scintillators, i.e. Gd2O2S:Tb for LDR-BT, and Y2O3:Eu+4YVO4:Eu for HDR-BT, dispersed in a polymer host. The shape and size of the tips are optimized using non-sequential ray tracing simulations towards maximizing the collection and coupling of the scintillation signal into the POF. They are then manufactured by means of a custom moulding process implemented on a commercial hot embossing machine, paving the way towards series production. Dosimetry experiments in water phantoms show that both the HDR-BT and LDR-BT sensors feature good consistency in the magnitude of the average photon count rate and that the photon count rate signal is not significantly affected by variations in sensor tip composition and geometry. Whilst individual calibration remains necessary, the proposed dosimeters show great potential for in-vivo dosimetry for brachytherapy.


Subject(s)
Biosensing Techniques , Brachytherapy , Radiation Dosimeters , Optical Fibers , Polymers
11.
J Radiol Prot ; 44(2)2024 Apr 03.
Article in English | MEDLINE | ID: mdl-38507786

ABSTRACT

Vision badge is an eye lens dosimeter to measureHp(3). This study aimed to evaluate the basic characteristics of the Vision badge and its performance as an eye lens dosimeter for endoscopists by phantom study. Energy dependence was evaluated by changing the tube voltage to 50 kV (effective energy of 27.9 keV), 80 kV (32.2 keV), and 120 kV (38.7 keV). Dose linearity was evaluated by changing the number of irradiation to 1, 5, and 40 times, which corresponded to 0.53, 5.32, and 21.4 mGy. Batch uniformity was evaluated by calculating the coefficient of variation ofHp(3) obtained from 10 Vision badges. Angular dependence was evaluated at 0° (perpendicular to the incident direction of x-rays), 30°, 60°, 75°, and 90°. The Vision badge and optically stimulated luminescence (OSL) dosimeter were attached to the inside of the radioprotective glasses, worn on the endoscopist phantom, and theHp(3) obtained from both dosimeters were compared. TheHp(3) obtained from the Vision badge with 38.7 keV was 3.8% higher than that with 27.9 keV. The Vision badge showed excellent linearity (R2= 1.00) with the air kerma up to 21.4 mGy. The coefficient of variation of theHp(3) for 10 Vision badges was 3.47%. The relative dose of the Vision badge decreased as the angle increased up to 75°, but increased at 90°. TheHp(3) obtained by the OSL dosimeter and the Vision badge were decreased as the endoscopist phantom was turned away from the patient phantom. TheHp(3) that was obtained by the Vision badge was 35.5%-55.0% less than that obtained by the nanoDot. In conclusion, the Vision badge showed specific angular dependence due to its shape, but satisfactory basic properties were exhibited for all characteristics. In phantom study, the Vision badge showed generally similar trends with the OSL dosimeter.


Subject(s)
Lens, Crystalline , Radiation Dosimeters , Humans , Radiography , X-Rays , Phantoms, Imaging , Lens, Crystalline/radiation effects
12.
Health Phys ; 126(5): 322-338, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38526251

ABSTRACT

ABSTRACT: Radiation exposure is a primary concern in emergency response scenarios and long-term health assessments. Accurate quantification of radiation doses is critical for informed decision-making and patient care. This paper reviews the dose reconstruction technique using both X- and Q-bands, with tooth enamel as a reliable dosimeter. Tooth enamel, due to its exceptional resistance to alteration over time, offers a unique opportunity for assessing both acute and chronic radiation exposures. This review delves into the principles underlying enamel dosimetry, the mechanism of radiation interactions, and dose retention in tooth enamel. We explore state-of-the-art analytical methods, such as electron paramagnetic resonance (EPR) spectroscopy, that accurately estimate low and high doses in acute and chronic exposure. Furthermore, we discuss the applicability of tooth enamel dosimetry in various scenarios, ranging from historical radiological incidents to recent nuclear events or radiological incidents. The ability to reconstruct radiation doses from dental enamel provides a valuable tool for epidemiological studies, validating the assessment of health risks associated with chronic exposures and aiding in the early detection and management of acute radiation incidents. This paper underscores the significance of tooth enamel as an essential medium for radiation dose reconstruction and its broader implications for enhancing radiation protection, emergency response, and public health preparedness. Incorporating enamel EPR dosimetry into standard protocols has the potential to transform the field of radiation assessment, ensuring more accurate and timely evaluations of radiation exposure and its associated risks.


Subject(s)
Radiation Exposure , Radiology , Humans , Electron Spin Resonance Spectroscopy , Radiation Exposure/adverse effects , Public Health , Radiation Dosimeters
13.
Phys Med Biol ; 69(9)2024 Apr 19.
Article in English | MEDLINE | ID: mdl-38530300

ABSTRACT

Objective.The successful implementation of FLASH radiotherapy in clinical settings, with typical dose rates >40 Gy s-1, requires accurate real-time dosimetry.Approach.Silicon carbide (SiC) p-n diode dosimeters designed for the stringent requirements of FLASH radiotherapy have been fabricated and characterized in an ultra-high pulse dose rate electron beam. The circular SiC PiN diodes were fabricated at IMB-CNM (CSIC) in 3µm epitaxial 4H-SiC. Their characterization was performed in PTB's ultra-high pulse dose rate reference electron beam. The SiC diode was operated without external bias voltage. The linearity of the diode response was investigated up to doses per pulse (DPP) of 11 Gy and pulse durations ranging from 3 to 0.5µs. Percentage depth dose measurements were performed in ultra-high dose per pulse conditions. The effect of the total accumulated dose of 20 MeV electrons in the SiC diode sensitivity was evaluated. The temperature dependence of the response of the SiC diode was measured in the range 19 °C-38 °C. The temporal response of the diode was compared to the time-resolved beam current during each electron beam pulse. A diamond prototype detector (flashDiamond) and Alanine measurements were used for reference dosimetry.Main results.The SiC diode response was independent both of DPP and of pulse dose rate up to at least 11 Gy per pulse and 4 MGy s-1, respectively, with tolerable deviation for relative dosimetry (<3%). When measuring the percentage depth dose under ultra-high dose rate conditions, the SiC diode performed comparably well to the reference flashDiamond. The sensitivity reduction after 100 kGy accumulated dose was <2%. The SiC diode was able to follow the temporal structure of the 20 MeV electron beam even for irregular pulse estructures. The measured temperature coefficient was (-0.079 ± 0.005)%/°C.Significance.The results of this study demonstrate for the first time the suitability of silicon carbide diodes for relative dosimetry in ultra-high dose rate pulsed electron beams up to a DPP of 11 Gy per pulse.


Subject(s)
Carbon Compounds, Inorganic , Radiation Dosimeters , Radiometry , Radiometry/methods , Silicon Compounds , Electrons
14.
Int J Mol Sci ; 25(5)2024 Mar 02.
Article in English | MEDLINE | ID: mdl-38474163

ABSTRACT

This work presents an ecological, flexible 2D radiochromic dosimeter for measuring ionizing radiation in the kilogray dose range. Cotton woven fabric made of cellulose was volume-modified with nitrotetrazolium blue chloride as a radiation-sensitive compound. Its features include a color change during exposure from yellowish to purple-brown and flexibility that allows it to adapt to various shapes. It was found that (i) the dose response is up to ~80 kGy, (ii) it is independent of the dose rate for 1.1-73.1 kGy/min, (iii) it can be measured in 2D using a flatbed scanner, (iv) the acquired images can be filtered using a mean filter, which improves its dose resolution, (v) the dose resolution is -0.07 to -0.4 kGy for ~0.6 to ~75.7 kGy for filtered images, and (vi) two linear dose subranges can be distinguished: ~0.6 to ~7.6 kGy and ~9.9 to ~62.0 kGy. The dosimeter combined with flatbed scanner reading and data processing using dedicated software packages constitutes a comprehensive system for measuring dose distributions for objects with complex shapes.


Subject(s)
Radiation Dosimeters , Radiation, Ionizing , Cellulose , Radiometry/methods
15.
Radiat Prot Dosimetry ; 200(6): 572-579, 2024 Apr 20.
Article in English | MEDLINE | ID: mdl-38465479

ABSTRACT

In the calibration procedure of area gamma dosemeters, how to accurately evaluate and correct the scattering contribution from the complex environmental factors to the point of test is the key problem to ensure the calibration accuracy. This paper proposed a fast correction method of the scattering contributions in the area gamma dosemeter calibration field. First, Monte Carlo method is employed to simulate the influence of scattering caused by different environmental factors in the calibration field, which is named as semi-panoramic reference radiation field. Then, a prediction model of the relationship between environmental factors and environmental scattering contribution is constructed based on the simulation data through the least squares support vector machine. With the model, the scattering contribution from the environmental factors can be fast estimated to correct the calibration results of the area gamma dosemeters, which will improve the accuracy of the calibration.


Subject(s)
Gamma Rays , Monte Carlo Method , Scattering, Radiation , Calibration , Radiation Monitoring/methods , Radiation Monitoring/instrumentation , Radiation Monitoring/standards , Humans , Radiation Dosimeters/standards , Algorithms , Support Vector Machine , Radiation Dosage , Computer Simulation
16.
Sensors (Basel) ; 24(3)2024 Jan 30.
Article in English | MEDLINE | ID: mdl-38339627

ABSTRACT

Source localisation and real-time dose verification are at the forefront of medical research in brachytherapy, an oncological radiotherapy procedure based on radioactive sources implanted in the patient body. The ORIGIN project aims to respond to this medical community's need by targeting the development of a multi-point dose mapping system based on fibre sensors integrating a small volume of scintillating material into the tip and interfaced with silicon photomultipliers operated in counting mode. In this paper, a novel method for the selection of the optimal silicon photomultipliers to be used is presented, as well as a laboratory characterisation based on dosimetric figures of merit. More specifically, a technique exploiting the optical cross-talk to maintain the detector linearity in high-rate conditions is demonstrated. Lastly, it is shown that the ORIGIN system complies with the TG43-U1 protocol in high and low dose rate pre-clinical trials with actual brachytherapy sources, an essential requirement for assessing the proposed system as a dosimeter and comparing the performance of the system prototype against the ORIGIN project specifications.


Subject(s)
Brachytherapy , Humans , Brachytherapy/methods , Radiotherapy Dosage , Radiation Dosimeters , Radiometry/methods , Software
17.
J Radiol Prot ; 44(1)2024 Mar 19.
Article in English | MEDLINE | ID: mdl-38306678

ABSTRACT

This research investigates the effects of new definitions of operational dosimetric quantities, especiallyHp(10) to Hp recommended by ICRU Report 95, on the dosimetry system. This paper focuses on the responses of two dosimeter types, nanoDot® and InLight®, using conversional coefficients from ICRU report 57 and ICRU report 95 conversion coefficients. The dosimeters were irradiated with various beam qualities, and their responses were compared to the acceptant limits provided by the IEC 62387. The results demonstrate higher responses at new definitions recommended by ICRU report 95, indicating the need for algorithm modifications in the dose calculation.


Subject(s)
Radiation Dosimeters , Radiometry , Radiation Dosage , Thailand , Radiometry/methods
18.
J Xray Sci Technol ; 32(3): 751-764, 2024.
Article in English | MEDLINE | ID: mdl-38217634

ABSTRACT

OBJECTIVE: It seems that dose rate (DR) and photon beam energy (PBE) may influence the sensitivity and response of polymer gel dosimeters. In the current project, the sensitivity and response dependence of optimized PASSAG gel dosimeter (OPGD) on DR and PBE were assessed. MATERIALS AND METHODS: We fabricated the OPGD and the gel samples were irradiated with various DRs and PBEs. Then, the sensitivity and response (R2) of OPGD were obtained by MRI at various doses and post-irradiation times. RESULTS: Our analysis showed that the sensitivity and response of OPGD are not affected by the evaluated DRs and PBEs. It was also found that the dose resolution values of OPGD ranged from 9 to 33 cGy and 12 to 34 cGy for the evaluated DRs and PBEs, respectively. Additionally, the data demonstrated that the sensitivity and response dependence of OPGD on DR and PBE do not vary over various times after the irradiation. CONCLUSIONS: The findings of this research project revealed that the sensitivity and response dependence of OPGD are independent of DR and PBE.


Subject(s)
Gels , Magnetic Resonance Imaging , Photons , Radiation Dosimeters , Magnetic Resonance Imaging/methods , Gels/chemistry , Polymers/chemistry , Radiometry/methods , Radiometry/instrumentation
19.
Z Med Phys ; 34(1): 111-139, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37225603

ABSTRACT

Ionizing radiation in general and mixed fields of space radiation in particular pose a risk of serious harm to human health. The risk of such adverse effects increases with the duration of the mission, and for all missions outside the protective properties of the Earth's magnetic field and atmosphere. Accordingly, radiation protection is of central importance for all human spaceflight, which is recognized by all international space agencies. To date various systems, analyze and determine the exposure to ionizing radiation within the environment and to the crew onboard the International Space Station (ISS). In addition to this operational monitoring, experiments and technology demonstrations are carried out. This to further enhance systems capabilities, to prepare for exploratory missions, to the Deep Space Gateway and/or to enable for human presence at other celestial bodies. Subsequently the European Space Agency (ESA) decided early to support the development of an active personal dosimeter. Under the auspices of the European Space Research and Technology Center (ESTEC) together with the European Astronaut Center's (EAC) Medical Operations and Space Medicine (HRE-OM) team, a European industrial consortium was formed to develop, build, and test this system. To complete the ESA Active Dosimeter (EAD) Technology Demonstration in space, EAD components were delivered to ISS with the ESA's space missions 'iriss' and 'proxima' in 2015 and 2016. This marked Phase 1 (2015) and 2 (2016-2017) of the EAD Technology Demonstration to which focus is given in this publication. All EAD systems and their functionalities, the different radiation detector, their properties, and calibrations procedures are described. Emphasis is first on the "iriss" mission of September 2015, that provided a complete set of data for an entire space mission from launch to landing, for the first time. Data obtained during Phase 2 in 2016-2017 are discussed thereafter. Measurements with the active radiation detectors of the EAD system provided data of the absorbed dose, dose equivalent, quality factor as well as the various dose contributions during the crossings of the South Atlantic Anomaly (SAA) and/or resulting from galactic cosmic radiation (GCR). Results of the in-flight cross-calibrations among the internal sensors of the EAD systems are discussed and alternative usage of the EAD Mobile Units as area monitors at various different locations inside the ISS is described.


Subject(s)
Cosmic Radiation , Radiation Monitoring , Space Flight , Humans , Radiation Dosimeters , Radiation Monitoring/methods , Astronauts , Radiation Dosage
20.
Med Phys ; 51(3): 2311-2319, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37991111

ABSTRACT

BACKGROUND: Dosimetry in ultra-high dose rate (UHDR) electron beamlines poses a significant challenge owing to the limited usability of standard dosimeters in high dose and high dose-per-pulse (DPP) applications. PURPOSE: In this study, Al2 O3 :C nanoDot optically stimulated luminescent dosimeters (OSLDs), single-use powder-based LiF:Mg,Ti thermoluminescent dosimeters (TLDs), and Gafchromic EBT3 film were evaluated at extended dose ranges (up to 40 Gy) in conventional dose rate (CONV) and UHDR beamlines to determine their usability for calibration and dose verification in the setting of FLASH radiation therapy. METHODS: OSLDs and TLDs were evaluated against established dose-rate-independent Gafchromic EBT3 film with regard to the potential influence of mean dose rate, instantaneous dose rate, and DPP on signal response. The dosimeters were irradiated at CONV or UHDR conditions on a 9-MeV electron beam. Under UHDR conditions, different settings of pulse repetition frequency (PRF), pulse width (PW), and pulse amplitude were used to characterize the individual dosimeters' response in order to isolate their potential dependencies on dose, dose rate, and DPP. RESULTS: The OSLDs, TLDs, and Gafchromic EBT3 film were found to be suitable at a dose range of up to 40 Gy without any indication of saturation in signal. The response of OSLDs and TLDs in UHDR conditions were found to be independent of mean dose rate (up to 1440 Gy/s), instantaneous dose rate (up to 2 MGy/s), and DPP (up to 7 Gy), with uncertainties on par with nominal values established in CONV beamlines (± 4%). In cross-comparing the response of OSLDs, TLDs and Gafchromic film at dose rates of 0.18-245 Gy/s, the coefficient of variation or relative standard deviation in the measured dose between the three dosimeters (inter-dosimeter comparison) was found to be within 2%. CONCLUSIONS: We demonstrated the dynamic range of OSLDs, TLDs, and Gafchromic film to be suitable up to 40 Gy, and we developed a protocol that can be used to accurately translate the measured signal in each respective dosimeter to dose. OSLDs and powdered TLDs were shown to be viable for dosimetric measurement in UHDR beamlines, providing dose measurements with accuracies on par with Gafchromic EBT3 film and their concurrent use demonstrating a means for redundant dosimetry in UHDR conditions.


Subject(s)
Radiation Dosimeters , Titanium , Radiation Dosage , Thermoluminescent Dosimetry/methods , Radiometry/methods