Results 1 - 20 de 2.694
Filter
1.
Arch Microbiol ; 206(7): 314, 2024 Jun 20.
Article in English | MEDLINE | ID: mdl-38900289

ABSTRACT

In the field of metagenomic research, the choice of DNA extraction methods plays a pivotal yet often underestimated role in shaping the reliability and interpretability of microbial community data. This study delves into the impact of five commercially available DNA extraction kits on the analysis of bovine fecal microbiota. Recognizing the importance of accurate DNA extraction in elucidating microbial community dynamics, we systematically assessed DNA yield, quality, and microbial composition across these kits using 16S rRNA gene sequencing. Notably, the FastDNA spin soil kit yielded the highest DNA concentration, while significant variations in quality were observed across kits. Furthermore, differential abundance analysis revealed kit-specific biases that impacted taxa representation. Microbial richness and diversity were significantly influenced by the choice of extraction kit, with QIAamp DNA stool minikit, QIAamp Power Pro, and DNeasy PowerSoil outperforming the Stool DNA Kit. Principal-coordinate analysis revealed distinct clustering based on DNA isolation procedures, particularly highlighting the unique microbial community composition derived from the Stool DNA Kit. This study also addressed practical implications, demonstrating how kit selection influences the concentration of Gram-positive and Gram-negative bacterial taxa in samples. This research highlights the need for consideration of DNA extraction kits in metagenomic studies, offering valuable insights for researchers striving to advance the precision and depth of microbiota analyses in ruminants.


Subject(s)
DNA, Bacterial , Feces , RNA, Ribosomal, 16S , Animals , Cattle , Feces/microbiology , RNA, Ribosomal, 16S/genetics , DNA, Bacterial/genetics , DNA, Bacterial/isolation & purification , Bacteria/genetics , Bacteria/isolation & purification , Bacteria/classification , Metagenomics , Sequence Analysis, DNA , Reagent Kits, Diagnostic/standards , Microbiota/genetics
2.
J Immunol Methods ; 530: 113693, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38797276

ABSTRACT

BACKGROUND: Manufacturers and diagnostic companies often recommend on-site verification of analytical performance in the clinical laboratory. The validation process used by manufacturers is rarely described in detail, and certain information on analytical performance is missing from the product sheet, especially for immunoanalytical methods. We describe an approach to the detailed validation of an ELISA method for the measurement of proprotein convertase subtilisin/kexin type 9 (PCSK9) plasma concentrations. We compared manufacturers' claims of analytical performance with data obtained in the field laboratory using several approaches. METHODS: We used the Human Proprotein Convertase 9/PCSK9 Quantikine ELISA diagnostic kit (R&D systems, Bio-Techne Ltd., Abingdon Science Park, Abingdon, UK) and three levels of quality control solution Quantikine Immunoassay Control Group 235 (R&D systems, Bio-Techne Ltd., Abingdon Science Park, Abingdon, UK) to verify precision. We measured the concentration of PCSK9 using the DS2 ELISA Reader (Dynex Technologies GmbH, Denkendorf, Germany). We used analysis of variance (ANOVA) and the R statistical package (R core team, version 1.4.5). Statistical analysis and terminology were performed according to protocol CLSI EP15-A3, and the reference interval was checked according to CLSI/IFCC C28-A3c. RESULTS: We found a significant difference between the manufacturer's claims of analytical performance and real data measured in the routine clinical laboratory. The calculated CV (%) for repeatability (calculated by simple estimation of the mean and SD, as used by the manufacturer) was between 5.5% and 7.4%, but the manufacturer's claim was between 4.1% and 6.5%. Using ANOVA, the true repeatability was between 5.0% and 6.9%. Similarly, ANOVA revealed values of CV (%) for within-laboratory imprecision between 6.5% and 9.1%, while the manufacturer's claims were between 4.1% and 5.9%. The recovery ranged from 105.5% to 121.8%. The manufacturer's recommended reference interval was checked and we didn't find any significant difference between men and women. CONCLUSIONS: We describe a comprehensive approach to verify the analytical performance of an ELISA method using the measurement of PCSK9 plasma concentration as an example. We found differences between the results of this approach based on the CLSI EP15-A3 protocol and data provided by the manufacturer. We recommend the verification of analytical performance by more complex statistical tools in laboratory practice.


Subject(s)
Enzyme-Linked Immunosorbent Assay , Proprotein Convertase 9 , Humans , Proprotein Convertase 9/blood , Proprotein Convertase 9/immunology , Enzyme-Linked Immunosorbent Assay/standards , Enzyme-Linked Immunosorbent Assay/methods , Reproducibility of Results , Female , Male , Reagent Kits, Diagnostic/standards , Quality Control
3.
Ann Biol Clin (Paris) ; 82(2): 215-224, 2024 06 05.
Article in French | MEDLINE | ID: mdl-38702909

ABSTRACT

The Westgard quality control (QC) rules are often applied in infectious diseases serology to validate the quality of results, but this requires a reasonable tradeoff between maximum sensitivity to errors and minimum false rejections. This article, in addition to illustrate the six sigma methodology in the QC management of the (anti-HCV Architect®) test, it discusses the main influencing factors on sigma value. Data from low positive and in-kit control materials spreading over 6 months and using four reagent kits, were used to calculate the precision of the test. The difference between the control material reactivity and the cut-off defined the error budget. Sigma values were > 6, which indicates that the method produces four erroneous results per million tests. The application of the six sigma concept made it possible to argue the choice of the new QC strategy (use of 13S rule with one positive control) and to relax the existing QC rules. This work provides a framework for infectious diseases serology laboratories to evaluate tests performances against a quality requirement and design an optimal QC strategy.


Subject(s)
Hepatitis C , Quality Control , Serologic Tests , Total Quality Management , Humans , Hepatitis C/blood , Hepatitis C/diagnosis , Total Quality Management/standards , Serologic Tests/standards , Serologic Tests/methods , Hepatitis C Antibodies/blood , Hepatitis C Antibodies/analysis , Hepacivirus/isolation & purification , Hepacivirus/immunology , Sensitivity and Specificity , Reagent Kits, Diagnostic/standards , Reproducibility of Results , Quality Assurance, Health Care/standards , Quality Assurance, Health Care/methods , Laboratories, Clinical/standards
4.
J Clin Microbiol ; 62(6): e0013624, 2024 Jun 12.
Article in English | MEDLINE | ID: mdl-38727213

ABSTRACT

HIV genotyping is used to assess HIV susceptibility to antiretroviral drugs. The Applied Biosystems HIV-1 Genotyping Kit with Integrase (AB kit, Thermo Fisher Scientific) detects resistance-associated mutations (RAMs) in HIV protease (PR), reverse transcriptase (RT), and integrase (IN). We compared results from the AB kit with results obtained previously with the ViroSeq HIV-1 Genotyping System. DNA amplicons from the AB kit were also analyzed using next-generation sequencing (NGS). HIV RNA was extracted using the MagNA Pure 24 instrument (Roche Diagnostics; 96 plasma samples, HIV subtype B, viral load range: 530-737,741 copies/mL). FASTA files were generated from AB kit data using Exatype (Hyrax Biosciences). DNA amplicons from the AB kit were also analyzed by NGS using the Nextera XT kit (Illumina). Drug resistance was predicted using the Stanford HIV Drug Resistance Database. The mean genetic distance for sequences from ViroSeq and the AB kit was 0.02% for PR/RT and 0.04% for IN; 103 major RAMs were detected by both methods. Four additional major RAMs were detected by the AB kit only. These four major RAMs were also detected by NGS (detected in 18.1%-38.2% of NGS reads). NGS detected 27 major RAMs that were not detected with either of the Sanger sequencing-based kits. All major RAMs detected with ViroSeq were detected with the AB kit; additional RAMs were detected with the AB kit only. DNA amplicons from the AB kit can be used for NGS for more sensitive detection of RAMs.


Subject(s)
Drug Resistance, Viral , Genotyping Techniques , HIV Infections , HIV Integrase , HIV-1 , High-Throughput Nucleotide Sequencing , HIV-1/genetics , HIV-1/drug effects , HIV-1/enzymology , HIV-1/isolation & purification , HIV-1/classification , Humans , HIV Infections/virology , Genotyping Techniques/methods , Drug Resistance, Viral/genetics , HIV Integrase/genetics , High-Throughput Nucleotide Sequencing/methods , Genotype , Reagent Kits, Diagnostic/standards , RNA, Viral/genetics , Mutation , HIV Reverse Transcriptase/genetics , HIV Protease/genetics
5.
Braz J Microbiol ; 55(2): 1801-1809, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38709438

ABSTRACT

Dengue necessitates accurate diagnosis. Rapid tests such as Bioline™ DENGUE DUO have gained traction, but validation in specific populations is essential. This study aimed to evaluate the performance of the Bioline™ test, alongside assessing the socio-epidemiological profile of symptomatic patients in a Brasília Military Hospital. The serum of 404 symptomatic patients was analyzed by the Bioline™ DENGUE DUO test, followed by Dengue virus detection and discrimination of the four serotypes by RT-qPCR. Accuracy was assessed using parameters including sensitivity (S), specificity (E), positive and negative predictive values (PPV and NPV), and positive (RV +) and negative (RV-) likelihood ratios. The NS1 component exhibited a sensitivity of 70.37%, a specificity of 97.30%, and an overall efficiency of 90.10% when compared to RT-qPCR as the gold standard. The IgM component demonstrated a sensitivity of 26.85%, a specificity of 89.53%, and an overall efficiency of 72.77% when compared to RT-qPCR as the gold standard. The IgG component demonstrated a sensitivity of 23.15%, a specificity of 68.92%, and an overall efficiency of 56.68% when compared to RT-qPCR as the gold standard. Several rapid tests are commercially available. However, considering variations across regions and demographic groups, it is important to question their accuracy in specific populations. Rapid tests are important screening tools, but they can have limitations for the certainty of diagnosis. Bioline™ DENGUE DUO displayed good specificity, but sensitivity was slightly below optimal levels. While helpful for confirming dengue, improvements are needed to effectively rule out the disease.


Subject(s)
Dengue Virus , Dengue , Hospitals, Military , Sensitivity and Specificity , Humans , Dengue/diagnosis , Dengue/blood , Dengue/virology , Brazil/epidemiology , Dengue Virus/immunology , Dengue Virus/genetics , Dengue Virus/isolation & purification , Female , Male , Adult , Middle Aged , Young Adult , Adolescent , Antibodies, Viral/blood , Child , Aged , Immunoglobulin M/blood , Child, Preschool , Reagent Kits, Diagnostic/standards
6.
J Clin Virol ; 173: 105680, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38728796

ABSTRACT

BACKGROUND: Epstein-Barr Virus (EBV) viral loads in hematopoietic stem cell transplant (HSCT) recipients are typically monitored using quantitative molecular assays. The Cobas EBV test (Roche Molecular, Pleasanton, CA) has recently been FDA-cleared for the monitoring of EBV viral loads in plasma samples of transplant patients. In this study, we compared the viral loads obtained by a laboratory-developed test (EBV LDT) using Altona Analyte specific reagents (ASR) to those obtained on the Cobas EBV test. METHODS: The analytical performance of the assay was established using the EBV verification panel from Exact Diagnostics and the EBV ATCC strain B95-8. The clinical evaluation was performed using 343 plasma samples initially tested on the EBV LDT. RESULTS: The analytical sensitivity (<18.8 IU/mL), precision (SD < 0.17 log) and linear range (35.0 IU/mL to 1E + 08 IU/mL) of the Cobas EBV assay established by the manufacturers were confirmed. The strength of the qualitative agreement was substantial between the cobas EBV and the EBV LDT (85.6 %; κ = 0.71) and almost perfect when discordant results were resolved (96.4 %; κ = 0.93). The quantitative agreement was moderate (82.9 %; κ = 0.53) with the viral load obtained on the Cobas EBV test being lower across the linear range of the two tests (mean log difference of 1.0). While the absolute values of the viral loads were markedly different, the overall trends observed in patients with multiple consecutive results were similar between the two tests. CONCLUSIONS: The Cobas EBV test provides an accurate and valid, in vitro diagnostic (IVD) option for monitoring of EBV viral loads in transplant patients and should provide an opportunity for increased standardization and commutability of tests results across laboratories.


Subject(s)
Epstein-Barr Virus Infections , Herpesvirus 4, Human , Sensitivity and Specificity , Tertiary Care Centers , Viral Load , Humans , Viral Load/methods , Epstein-Barr Virus Infections/diagnosis , Epstein-Barr Virus Infections/virology , Herpesvirus 4, Human/isolation & purification , Herpesvirus 4, Human/genetics , Middle Aged , Female , Adult , Male , Aged , Young Adult , Adolescent , Molecular Diagnostic Techniques/methods , Molecular Diagnostic Techniques/standards , Hematopoietic Stem Cell Transplantation , Child , Child, Preschool , DNA, Viral/blood , Reagent Kits, Diagnostic/standards
7.
Diagn Microbiol Infect Dis ; 109(4): 116357, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38776663

ABSTRACT

We aimed to compare the NeuMoDx HBV Assay with the artus HBV Assay using residual plasma samples and to evaluate the discordant results. The study included 200 patient samples analyzed with the NMD assay and stored at -80 °C. Samples were analyzed by artus in 2023. Discordant results were evaluated by cobas 6800 HBV DNA Test. Excellent agreement was found between both tests. Of the 100 samples that were HBV DNA negative by NMD, 93 were negative and 7 were positive by artus. With the Cobas test, 5 samples were positive. Of the100 HBV DNA positive samples detected by NMD, 99 were positive with the artus assay. This sample was also HBV DNA negative by the Cobas test. The sensitivity and specificity of NeuMoDx were found 93 % and 99 %, respectively. There was excellent qualitative agreement and strong quantitative correlation between the NeuMoDx and artus assays for HBV DNA detection and quantitation.


Subject(s)
DNA, Viral , Hepatitis B virus , Hepatitis B , Sensitivity and Specificity , Humans , DNA, Viral/blood , Hepatitis B virus/genetics , Hepatitis B virus/isolation & purification , Hepatitis B/diagnosis , Hepatitis B/virology , Hepatitis B/blood , Viral Load/methods , Reagent Kits, Diagnostic/standards , Molecular Diagnostic Techniques/methods , Molecular Diagnostic Techniques/standards , Plasma/virology
8.
J Med Virol ; 96(5): e29686, 2024 May.
Article in English | MEDLINE | ID: mdl-38767142

ABSTRACT

Comparison of diagnostic accuracy for commercial hepatitis C virus (HCV) genotyping (Abbott RealTime HCV Genotyping II, Roche Cobas Genotyping) and investigational Abbott HCV Genotype plus RUO assays designed to discriminate genotype (GT)-1a, 1b or 6 in cases of ambiguous GT from the Abbott commercial assay remains limited. 743 HCV-viremic samples were subjected to analysis using Abbott and Roche commercial as well as Abbott HCV Genotype plus RUO assays. Next-generation sequencing (NGS) targeting core region was employed as the reference standard. Diagnostic accuracy was reported as the number of participants (percentages) along with 95% confidence intervals (CIs). Using NGS, 741 samples (99.7%) yielded valid genotyping results. The diagnostic accuracies were 97.6% (95% CI: 96.1%-98.5%) and 95.3% (95% CI: 93.4%-96.6%) using Abbott and Roche commercial assays (p = 0.0174). Abbott commercial assay accurately diagnosed HCV GT-6a and 6w, whereas Roche commercial assay accurately diagnosed HCV GT-6a. Both assays demonstrated low accuracies for HCV GT-6b, 6e, 6g, and 6n. Abbott HCV Genotype plus RUO assay discriminated 13 of the 14 samples (92.9%; 95% CI: 64.2%-99.6%) that yielded ambiguous GT. Both assays were capable of diagnosing mixed HCV infections when the minor genotype comprised >8.4% of the viral load. The diagnostic performance of commercial HCV genotyping assays is commendable. Abbott assay demonstrated superior performance compared to Roche assay in diagnosing HCV GT-6. Abbott HCV Genotype plus RUO assay aids in discriminating ambiguous GT. Both commercial assays are proficient in diagnosing mixed HCV infections at a cut-off viral load of 8.4% in minor genotype.


Subject(s)
Genotype , Genotyping Techniques , Hepacivirus , Hepatitis C , High-Throughput Nucleotide Sequencing , Humans , Hepacivirus/genetics , Hepacivirus/classification , Hepacivirus/isolation & purification , Genotyping Techniques/methods , High-Throughput Nucleotide Sequencing/methods , Hepatitis C/diagnosis , Hepatitis C/virology , Molecular Diagnostic Techniques/methods , Sensitivity and Specificity , Reagent Kits, Diagnostic/standards , Female , Male , Middle Aged , Adult
9.
PLoS One ; 19(5): e0302840, 2024.
Article in English | MEDLINE | ID: mdl-38713676

ABSTRACT

Malaria rapid diagnostic test (mRDT) kit is one of the techniques for diagnosing malaria. Due to its inherent advantages over the microscopy technique, several brands of the kit have flooded malaria endemic countries, without prior in-country evaluation. Two of such mRDT kits are Oscar (India) and Standard Q (Korea Republic). In this study, the performance of Oscar and Standard Q mRDT kits were compared to First Response (India) and CareStart (USA) mRDTs, which have been evaluated and deployed for use approved by the Ministry of Health (MOH). In this comparative study, whole blood samples were collected from patients suspected of malaria. Plasmodium falciparum was detected in each sample using nested polymerase chain reaction (nPCR), microscopy and the four mRDTs. The sensitivities, specificities, accuracies, positive and negative predictive values and accuracies of the mRDTs were determined using nPCR as a reference technique. Kappa statistic was used to determine the level of agreement among the techniques. Two hundred (200) blood samples were analyzed in this study. The overall detection rates of P. falciparum by microscopy, First Response, CareStart, Oscar-PfHRP2, Standard Q mRDT kits and nPCR were 31.5%, 34.5%, 33.5%, 32%, 31% and 43% (x2 = 6.1, p = 0.046), respectively. The accuracies of CareStart and First Response were comparable (90.5% vs. 89.5%). Further, comparing their sensitivities, Oscar-PfHRP2 was 74.4% (95% confidence interval (CI): 63.9-83.2) while that of Standard Q was 72.1% (95% CI: 61.4-81.2), with comparable accuracies (Oscar-PfHRP2-89% and Standard Q -88%). Apart from First Response that was 98.3% specific, the others were 100% specific. Kappa test revealed perfect diagnostic agreement (κ = 0.90-0.98) among the four mRDTs. That notwithstanding, Oscar-PfHRP2 agreed better with CareStart (κ = 0.94) and First Response (κ = 0.92) compared to the agreement between Standard Q and, CareStart (κ = 0.92) and First Response (κ = 0.90). Taken together, the diagnostic performance of the four mRDT kits were statistically similar. That notwithstanding, new mRDT kits should be evaluated prior to deployment for use.


Subject(s)
Diagnostic Tests, Routine , Malaria, Falciparum , Plasmodium falciparum , Reagent Kits, Diagnostic , Sensitivity and Specificity , Humans , Reagent Kits, Diagnostic/standards , Plasmodium falciparum/isolation & purification , Plasmodium falciparum/genetics , Malaria, Falciparum/diagnosis , Malaria, Falciparum/parasitology , Malaria, Falciparum/blood , Ghana , Diagnostic Tests, Routine/methods , Female , Male , Adult , Child , Adolescent , Middle Aged , Child, Preschool , Young Adult , Antigens, Protozoan/blood , Polymerase Chain Reaction/methods , Microscopy/methods , Infant , Rapid Diagnostic Tests
10.
PLoS One ; 19(5): e0303477, 2024.
Article in English | MEDLINE | ID: mdl-38809884

ABSTRACT

Rapid syphilis testing plays a crucial role in global health strategies, addressing the urgent need for prompt and accurate diagnostics, especially in settings with limited resources. Despite their practical utility, these tests often lack thorough validation, leading to concerns about their efficacy and reliability. This study aims to evaluate two prototypes of the Onsite Syphilis Ab Combo Rapid Test (Fd and Ff) and compare their performance with the established chemiluminescent microparticle immunoassay (CMIA) method. Employing a reverse algorithm approach, the study analyzed 450 serum samples, including those from syphilis patients, healthy individuals, and cases with potential cross-reactions. Results of the rapid test kit were then correlated with CMIA findings, RPR, and TPPA titers. The results showed that prototype Fd exhibited a sensitivity of 100.0%, specificity of 98.8%, positive predictive value (PPV) of 8.4%, negative predictive value (NPV) of 100.00% and accuracy of 98.8%. Similarly, prototype Ff exhibited sensitivity of 100.0%, but with a slightly higher specificity of 99.6%, PPV of 21.5%, NPV of 100.0% and accuracy of 99.6%. Moreover, both prototypes Fd and Ff of the Onsite Syphilis Ab Combo Rapid Test demonstrated significant efficacy diagnostic tool, offering clear and straightforward interpretation for clinicians in varied CMIA, RPR and TPPA titer scenarios. The Onsite Syphilis Ab Combo Rapid Test prototypes, Fd and Ff, demonstrated high sensitivity and specificity, comparable to CMIA methods. The effectiveness highlights their suitability for syphilis screening, particularly in non-laboratory settings or situations requiring immediate results. The validation of these prototypes supports their integration into current syphilis diagnostic algorithms, potentially contributing to improved public health outcomes.


Subject(s)
Antibodies, Bacterial , Reagent Kits, Diagnostic , Sensitivity and Specificity , Syphilis Serodiagnosis , Syphilis , Treponema pallidum , Humans , Treponema pallidum/immunology , Syphilis/diagnosis , Syphilis/blood , Syphilis/microbiology , Reagent Kits, Diagnostic/standards , Antibodies, Bacterial/blood , Antibodies, Bacterial/immunology , Syphilis Serodiagnosis/methods , Male , Female , Adult , Middle Aged , Immunoassay/methods , Reproducibility of Results , Rapid Diagnostic Tests
11.
Sci Rep ; 14(1): 10612, 2024 05 09.
Article in English | MEDLINE | ID: mdl-38719936

ABSTRACT

Molecular diagnostics involving nucleic acids (DNA and RNA) are regarded as extremely functional tools. During the 2020 global health crisis, efforts intensified to optimize the production and delivery of molecular diagnostic kits for detecting SARS-CoV-2. During this period, RT-LAMP emerged as a significant focus. However, the thermolability of the reagents used in this technique necessitates special low-temperature infrastructure for transport, storage, and conservation. These requirements limit distribution capacity and necessitate cost-increasing adaptations. Consequently, this report details the development of a lyophilization protocol for reagents in a colorimetric RT-LAMP diagnostic kit to detect SARS-CoV-2, facilitating room-temperature transport and storage. We conducted tests to identify the ideal excipients that maintain the molecular integrity of the reagents and ensure their stability during room-temperature storage and transport. The optimal condition identified involved adding 5% PEG 8000 and 75 mM trehalose to the RT-LAMP reaction, which enabled stability at room temperature for up to 28 days and yielded an analytical and diagnostic sensitivity and specificity of 83.33% and 90%, respectively, for detecting SARS-CoV-2. This study presents the results of a lyophilized colorimetric RT-LAMP COVID-19 detection assay with diagnostic sensitivity and specificity comparable to RT-qPCR, particularly in samples with high viral load.


Subject(s)
COVID-19 , Colorimetry , Freeze Drying , Molecular Diagnostic Techniques , Nucleic Acid Amplification Techniques , RNA, Viral , SARS-CoV-2 , Humans , COVID-19/diagnosis , COVID-19/virology , SARS-CoV-2/isolation & purification , SARS-CoV-2/genetics , Colorimetry/methods , Nucleic Acid Amplification Techniques/methods , Molecular Diagnostic Techniques/methods , RNA, Viral/analysis , RNA, Viral/genetics , Sensitivity and Specificity , Reagent Kits, Diagnostic/standards , COVID-19 Nucleic Acid Testing/methods
12.
Diagn Microbiol Infect Dis ; 109(3): 116348, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38759432

ABSTRACT

Bordetella pertussis is the causative pathogen of whooping cough or pertussis, a contagious respiratory disease. Aside from serodiagnosis, laboratory confirmation of pertussis is done through PCR, as B. pertussis is difficult to culture. The ELITe InGenius instrument (ELITechGroup, France) with accompanying Bordetella ELITe MGB Kit was evaluated against a laboratory-developed assay. Both assays combine two screening (IS481, IS1001) and two confirmation targets (recA, ptxA-Pr or IS1002) for optimal sensitivity and specificity. The company's stated claims on sensitivity and reproducibility were confirmed. Accuracy testing showed full concordance between both assays for the screening targets. Minor discrepancies were seen for the B. pertussis confirmation target. Some cross-reactivity with other Bordetella species was observed for the IS481-target, however, none of these were confirmed in the ptxA-Pr target. These results show the suitability of the Bordetella ELITe MGB Kit for the detection and differentiation of B. pertussis, B. parapertussis and B. holmesii.


Subject(s)
Bordetella pertussis , Bordetella , Sensitivity and Specificity , Whooping Cough , Humans , Whooping Cough/diagnosis , Whooping Cough/microbiology , Bordetella pertussis/isolation & purification , Bordetella pertussis/genetics , Bordetella/isolation & purification , Bordetella/classification , Bordetella/genetics , Bordetella parapertussis/isolation & purification , Bordetella parapertussis/genetics , Bordetella Infections/diagnosis , Bordetella Infections/microbiology , Reproducibility of Results , Reagent Kits, Diagnostic/standards , Polymerase Chain Reaction/methods , Molecular Diagnostic Techniques/methods
13.
Diagn Microbiol Infect Dis ; 109(3): 116323, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38703530

ABSTRACT

PURPOSE: To evaluate the performance of a newly developed 2019-nCoV nucleic acid detection kit based on Ion Proton sequencing platform and make comparation with MGI Tech (DNBSEQ-G99) platform. METHODS: References and clinical samples were used to evaluate the precision, agreement rate, limit of detection (LOD), anti-interference ability and analytical specificity. Twenty-seven clinical specimens were used to make comparison between two platforms. RESULTS: The kit showed good intra-assay, inter-assay, inter-day precision between different operators and laboratories, fine agreement rate with references, a relatively low LOD of 1 × 103 copies/ml, anti-interference capability of 5 % whole blood and 1mg/ml mucin and no cross reaction with twenty-nine common clinical pathogens. Consistency of variant classification was observed between two platforms. The WGS from Ion Proton tended to have higher coverage and less missing data. CONCLUSIONS: The newly developed kit has shown satisfactory performances and excellent consistency with DNBSEQ-G99, making it a good alternative choice clinically.


Subject(s)
COVID-19 , SARS-CoV-2 , Sensitivity and Specificity , Humans , SARS-CoV-2/genetics , COVID-19/diagnosis , RNA, Viral/genetics , Limit of Detection , High-Throughput Nucleotide Sequencing/methods , COVID-19 Nucleic Acid Testing/methods , COVID-19 Nucleic Acid Testing/instrumentation , Reagent Kits, Diagnostic/standards
14.
Genes (Basel) ; 15(4)2024 04 16.
Article in English | MEDLINE | ID: mdl-38674432

ABSTRACT

Fecal specimens have long been regarded as promising sources for gastrointestinal cancer screening and have, thus, been extensively investigated in biomarker research. MicroRNAs (miRNAs) are small, non-coding RNA molecules involved in regulating various biological processes. They are commonly dysregulated during tumor development and exhibit differential expression in feces. To assess the preanalytical feasibility of fecal miRNA analysis, we systematically compared the performance of commonly used total RNA extraction methods. Fecal samples from healthy subjects were utilized for this evaluation. Various methods, including miRNeasy, Universal, Trizol, RNeasy, and mirVana kits, were employed to isolate total RNA. MiRNA expression analyses were conducted using TaqMan or SYBR Green qRT-PCR for a subset of miRNAs, with externally spiked-in cel-miR-39 used for normalization. Most methods demonstrated similar performance in terms of the total RNA concentration and purity. Externally spiked cel-miR-39 and endogenous miRNAs (RNU6b, miR-16, and miR-21) exhibited comparable concentrations across the different RNA isolation methods, whereas the RNeasy mini kit consistently yielded lower values. Our findings suggest that various isolation methods produce reproducible and comparable miRNA expression results, supporting the potential comparability and translational applicability of miRNA-based biomarker research in the future.


Subject(s)
Feces , MicroRNAs , Humans , Feces/chemistry , MicroRNAs/genetics , MicroRNAs/isolation & purification , Reagent Kits, Diagnostic/standards
15.
Am J Trop Med Hyg ; 110(6): 1237-1244, 2024 Jun 05.
Article in English | MEDLINE | ID: mdl-38593786

ABSTRACT

There are a variety of nontreponemal test (NTT) and treponemal test (TT) kits for the serologic diagnosis of syphilis. Because of the complexity of the infection (multiple clinical stages) and the different antigens used in these kits, a systematic evaluation of the accuracy of the currently available commercial tests is warranted. Our objective was to evaluate the performance of commercially available tests for the diagnosis of syphilis infection. In this study, we analyzed one NTT (Venereal Disease Research Laboratory [VDRL] test, Wiener Laboratories, Rosario, Argentina) and two TTs (fluorescent treponemal antibody absorption [FTA-ABS] test, Euroimmun, Lübeck, Germany, and syphilis recombinant ELISA v. 4.0 test [ELISA], Wiener Laboratories, Rosario, Argentina) using a panel of 187 samples, including serum samples from 31 individuals with primary syphilis, 77 with secondary syphilis, and 79 with latent syphilis. An additional 192 samples from uninfected individuals and 323 serum samples from individuals with other diseases were included. The sensitivities of the VDRL, ELISA, and FTA-ABS tests were 97.9%, 100%, and 96.3%, respectively. The VDRL and ELISA tests showed a specificity of 100%, and the FTA-ABS test showed a specificity of 99.5%. Accuracy was 98.9% for the VDRL test, 100% for the ELISA, and 97.9% for the FTA-ABS test. For primary, secondary, and latent syphilis, the ELISA achieved a diagnostic performance of 100%, whereas the sensitivity for the VDRL and FTA-ABS tests ranged from 96.8% to 98.7% and 93.7% to 98.7%, respectively. No difference was observed when the tests were used as traditional or reverse algorithms. In general, all three tests are able to discriminate positive and negative samples for syphilis, regardless of the diagnostic algorithm.


Subject(s)
Enzyme-Linked Immunosorbent Assay , Sensitivity and Specificity , Syphilis Serodiagnosis , Syphilis , Treponema pallidum , Humans , Syphilis/diagnosis , Syphilis/blood , Syphilis Serodiagnosis/methods , Syphilis Serodiagnosis/standards , Enzyme-Linked Immunosorbent Assay/methods , Treponema pallidum/immunology , Treponema pallidum/isolation & purification , Male , Antibodies, Bacterial/blood , Reagent Kits, Diagnostic/standards , Female , Fluorescent Treponemal Antibody-Absorption Test , Adult
16.
Eur J Clin Microbiol Infect Dis ; 43(6): 1139-1148, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38613705

ABSTRACT

OBJECTIVES: Analyse alternative methods of intrathecal antibody detection by comparing chemiluminescent immunoassay (CLIA) and enzyme-linked immunosorbent assay (ELISA) techniques to determine if CLIA can replace ELISA in the diagnosis of CNS infections. METHODS: A panel of 280 paired samples-cerebrospinal fluid (CSF) and serum-with known antibody reactivities (Varicella, n = 60; Measles, n = 120) and negative samples (n = 100) were used to evaluate the performance of six serological test kits (Enzygnost, VirClia®, and Serion ELISA (Measles and Variella). RESULTS: For Measles virus IgG, the VirClia® IgG monotest revealed 97% and 94% positive and negative agreement to the Enzygnost as reference test, respectively. In contrast, Serion ELISA kits yielded values of 18% and 90%. For the Varicella Zoster virus (VZV) IgG, the VirClia® IgG monotest showed 97% and 90% positive and negative agreement compared to Enzygnost. The Serion ELISA kits showed values of 55% and 86%, respectively. ROC analysis revealed that the areas under the curve for Measles and VZV IgGs were 0.7 and 0.852, respectively, using the Serion kit, and 0.963 and 0.955, for Vircell S.L CLIA technique. VirClia® monotest values were calculated using an antibody index cut-off of 1.3. CONCLUSION: The findings indicate that CLIA testing can improve antibody detection in CSF samples, aiding the diagnosis of infectious neurological impairments.


Subject(s)
Antibodies, Viral , Chickenpox , Enzyme-Linked Immunosorbent Assay , Immunoglobulin G , Luminescent Measurements , Measles virus , Measles , Humans , Immunoglobulin G/blood , Immunoglobulin G/cerebrospinal fluid , Measles/diagnosis , Measles/immunology , Antibodies, Viral/blood , Antibodies, Viral/cerebrospinal fluid , Luminescent Measurements/methods , Enzyme-Linked Immunosorbent Assay/methods , Child , Male , Female , Adult , Adolescent , Chickenpox/diagnosis , Chickenpox/immunology , Measles virus/immunology , Child, Preschool , Young Adult , Middle Aged , Herpesvirus 3, Human/immunology , Sensitivity and Specificity , Infant , Aged , Immunoassay/methods , Reagent Kits, Diagnostic/standards
17.
Diagn Microbiol Infect Dis ; 109(3): 116297, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38604076

ABSTRACT

The LAMPdirect Genelyzer KIT allows for the detection of SARS-CoV-2 RNA in saliva samples with a loop-mediated isothermal amplification (LAMP) method and generates results within 20 min. It has been approved by the Pharmaceuticals and Medical Devices Agency in Japan. In this study, the performance of the LAMPdirect Genelyzer KIT was compared with that of the RT-qPCR reference method using 50 nasopharyngeal swabs and 100 saliva samples. In addition, we evaluated the applicability of an alternative reverse transcriptase and the effects of an inactivation buffer. The total agreement rates were 80.0 % and 82.0 % for nasopharyngeal and saliva samples, respectively. When considering samples at the detection limit (50 copies/reaction) that increases the chance of transmission between humans, the total agreement rates were 100% and 94.1% for nasopharyngeal and saliva samples, respectively. The LAMP method is simple, fast, and inexpensive, making it useful for small medical institutions or rural areas.


Subject(s)
COVID-19 , Molecular Diagnostic Techniques , Nasopharynx , Nucleic Acid Amplification Techniques , RNA, Viral , SARS-CoV-2 , Saliva , Humans , Saliva/virology , SARS-CoV-2/genetics , SARS-CoV-2/isolation & purification , Nasopharynx/virology , Nucleic Acid Amplification Techniques/methods , RNA, Viral/genetics , RNA, Viral/isolation & purification , COVID-19/diagnosis , COVID-19/virology , Molecular Diagnostic Techniques/methods , Sensitivity and Specificity , Reagent Kits, Diagnostic/standards , COVID-19 Nucleic Acid Testing/methods , COVID-19 Nucleic Acid Testing/instrumentation , Specimen Handling/methods
18.
J Virol Methods ; 327: 114937, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38614281

ABSTRACT

Quantification of hepatitis C virus (HCV)-RNA in serum or plasma samples is an essential parameter in HCV diagnostics. Here, the NeuMoDx™Molecular System (Qiagen) was tested for the most common HCV genotypes and compared to the cobas c6800 system (Roche). HCV-RNA from 131 plasma/serum samples from chronically infected patients was determined in parallel on the NeuMoDx and c6800 systems. Linearity was analysed using the four most common HCV genotypes (1-4) in our cohort. The coefficient of variation (CV) within (intra-assay) and between (inter-assay) runs was calculated based on HCV-RNA concentration. Quantitative HCV-RNA results were highly correlated on both test systems (R2 = 0.7947; y = 0.94 x + 0.37). On average, the NeuMoDx and c6800 HCV RNA levels showed a mean difference of only 0.05 log10 IU/mL but with a broad distribution (±1.2 2 x SD). The NeuMoDx demonstrated very good linearity across all HCV genotypes tested at concentrations between 1.7 and 6.2 log10 IU/mL (R2 range: 0.9257-0.9991) with the highest mean coefficient of determination for genotype 1 (R2 = 0.9909). The mean intra- and inter-assay CV for both serum and plasma samples was <5 %. The NeuMoDx HCV-RNA Assay demonstrates high subtype-independent comparability, linearity, and reproducibility for the quantification of HCV-RNA in serum and plasma samples from chronically infected patients.


Subject(s)
Genotype , Hepacivirus , RNA, Viral , Viral Load , Humans , Hepacivirus/genetics , Hepacivirus/isolation & purification , RNA, Viral/blood , RNA, Viral/genetics , Viral Load/methods , Reproducibility of Results , Hepatitis C, Chronic/virology , Hepatitis C, Chronic/diagnosis , Hepatitis C, Chronic/blood , Sensitivity and Specificity , Hepatitis C/diagnosis , Hepatitis C/virology , Hepatitis C/blood , Molecular Diagnostic Techniques/methods , Molecular Diagnostic Techniques/standards , Reagent Kits, Diagnostic/standards
19.
J Clin Virol ; 173: 105663, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38471301

ABSTRACT

In the last few years, many manufacturers have developed new kits for plasma HIV-1 RNA quantification. Recently, a solution consisting of the ELITe InGenius® instrument and the HIV1 ELITe MGB®kit has been commercialized worldwide. Our aim was to compare its clinical performance with the Aptima® HIV-1 Quant Dx kit by Hologic, on a panel of HIV-1 group M circulating variants, representative of viral load levels found during the pre- and post-treatment follow-up of patients. The linearity was evaluated on the AcroMetrix® HIV-1 Panel. Clinical specificity was evaluated on 100 plasma samples negative for HIV; and clinical sensitivity and sequential follow-up were evaluated on 166 HIV-1 positive plasma samples from 126 patients. The linearity data showed a difference obtained for each point of less than 0.2 Log cp/mL. No amplification was found for the 100 HIV negative clinical specimens. The overall agreement between the two kits was 83.7 %; the differences corresponded to a slightly higher detection for the Aptima kit (with more samples detected below the lower limit of quantification). A Bland & Altman analysis of the quantifiable samples showed a mean difference of -0.05 Log and Spearman's coefficient was 0.975. Only six samples presented discrepancies (above 0.5 Log), but these differences were overall similar between the two kits. Our study has shown that the HIV1 ELITe MGB® Kit can be successfully used for the monitoring of patients infected with various epidemic HIV-1 strains, and for the precise quantification of the viral load.


Subject(s)
HIV Infections , HIV-1 , RNA, Viral , Reagent Kits, Diagnostic , Sensitivity and Specificity , Viral Load , Humans , HIV-1/genetics , HIV-1/isolation & purification , HIV Infections/virology , HIV Infections/diagnosis , HIV Infections/blood , RNA, Viral/blood , Reagent Kits, Diagnostic/standards , Plasma/virology
20.
J Clin Virol ; 172: 105671, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38518504

ABSTRACT

To suit the needs of the human papillomaviruses (HPV) community comprehensively, a range of commercial HPV tests with different performance characteristics are required. Four periodic inventories of commercial HPV molecular tests present in the global market were published previously in 2010, 2012, 2015 and 2020. For the fifth inventory, data were retrieved from internal files and a detailed search using the main bibliographic databases as well as general internet search without period or language restrictions was performed in December 2023. At least 264 distinct HPV tests (and 511 test variants) were available globally in December 2023. A small 2020-2023 net increase in total numbers was observed, but with a strong introduction/withdrawal dynamic: 86 new distinct HPV tests (and 141 variants) were introduced and 76 tests (and 55 variants) were withdrawn from the market in the last four years. Although quality improvement of some tests was recorded, half of all HPV tests are still without a single peer-reviewed publication, and 79 % of tests are without published evidence that demonstrate performance characteristics are in line with requirements agreed in the HPV community. Only a relatively small pool of tests fulfill the operational/performance characteristics required to meet the global cervical cancer screening challenge. Although clinical and analytical performance characteristics of many commercial HPV tests are largely unknown, such tests are used worldwide in daily clinical practice and research, with potentially deleterious consequences. Due to this long-lasting unfavorable situation, significant scope for improvement persists for both manufacturers of HPV tests and the HPV community.


Subject(s)
Molecular Diagnostic Techniques , Papillomaviridae , Papillomavirus Infections , Humans , Papillomavirus Infections/diagnosis , Papillomavirus Infections/virology , Papillomaviridae/genetics , Papillomaviridae/classification , Papillomaviridae/isolation & purification , Molecular Diagnostic Techniques/methods , Molecular Diagnostic Techniques/standards , Female , Uterine Cervical Neoplasms/diagnosis , Uterine Cervical Neoplasms/virology , Global Health , Reagent Kits, Diagnostic/standards , Human Papillomavirus Viruses