1.
PLoS One ; 19(6): e0305929, 2024.
Article in English | MEDLINE | ID: mdl-38917184

ABSTRACT

The underwater laser polarization detection technology integrates the polarization characteristics of light into the detection and identification of underwater targets. Addressing the challenge of poor accuracy in identifying targets in strong underwater scattering environments, this article proposes an overall scheme for a laser polarization underwater detection device that suppresses scatter using polarized pulse signals. By overcoming key technological barriers in the design of polarization-preserving optical detection systems and utilizing the method of differential amplitude to measure polarization, a laser polarization underwater detection device was developed and underwater polarization detection experiments were conducted, achieving precise detection of underwater targets. The results indicate that the underwater detection device we designed has a root mean square error of less than 5.7% to detect the polarization of the target, demonstrating the accuracy and precision of the underwater detection device.


Subject(s)
Lasers , Scattering, Radiation , Water , Light
2.
J Biomed Opt ; 29(7): 075001, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38912213

ABSTRACT

Significance: The depolarization of circularly polarized light (CPL) caused by scattering in turbid media reveals structural information about the dispersed particles, such as their size, density, and distribution, which is useful for investigating the state of biological tissue. However, the correlation between depolarization strength and tissue parameters is unclear. Aim: We aimed to examine the generalized correlations of depolarization strength with the particle size and wavelength, yielding depolarization diagrams. Approach: The correlation between depolarization intensity and size parameter was examined for single and multiple scattering using the Monte Carlo simulation method. Expanding the wavelength width allows us to obtain depolarization distribution diagrams as functions of wavelength and particle diameter for reflection and transparent geometries. Results: CPL suffers intensive depolarization in a single scattering against particles of various specific sizes for its wavelength, which becomes more noticeable in the multiple scattering regime. Conclusions: The depolarization diagrams with particle size and wavelength as independent variables were obtained, which are particularly helpful for investigating the feasibility of various particle-monitoring methods. Based on the obtained diagrams, several applications have been proposed, including blood cell monitoring, early embryogenesis, and antigen-antibody interactions.


Subject(s)
Light , Monte Carlo Method , Particle Size , Scattering, Radiation , Computer Simulation , Nephelometry and Turbidimetry/methods
3.
Phys Med Biol ; 69(14)2024 Jul 08.
Article in English | MEDLINE | ID: mdl-38942002

ABSTRACT

Objective.The use of uniform phantoms to assess the influence of x-ray scatter and antiscatter grids on x-ray angiography and fluoroscopy image quality disregards the influence of spatially variable x-ray attenuation of patients. The purpose of this work was to measure scatter to primary ratio (SPR) and antiscatter grid SNR improvement factor (KSNR) using experimental conditions which better mimic patient imaging conditions.Approach.Three adult-sized anthropomorphic phantoms were used. AP and lateral projection images of the thorax and abdomen were acquired with and without an antiscatter grid. Grids with ratio 15:1 and 29:1 (r15, r29) and x-ray fields of view 20, 25 (thorax) and 32, 42 cm (abdomen) were tested. Combined with a-priori measurements of grid scatter and primary transmission fractions, these images were used to calculate 2D SPR andKSNRmaps.Main results.Results demonstrated that measurements by uniform phantom do not describe the complex 2D SPR andKSNRdistributions associated with anthropomorphic phantoms. The regions of the images with the lowest primary x-ray intensity (greatest attenuation) had the highest SPR and the highestKSNRattributable to the grids. Considering all conditions, the 95th percentile of the SPR maps was in the range 42%-185% greater than the median values and that of theKSNRmaps was 4%-20% higher than the median values. The combined influences of SID 120 vs. 107 cm and r29 vs. r15 grid resulted inKSNRin the range 1.05-1.49.Significance.Performance of anti-scatter grids using anatomically complex phantoms highlights the substantial variation of SPR andKSNRwithin 2D images. Also, this work demonstrates the benefit of the prototype r29 grid for thoracic and abdominal angiography imaging conditions is substantial, especially for large patients and radiodense image regions.


Subject(s)
Angiography , Phantoms, Imaging , Scattering, Radiation , Humans , Angiography/instrumentation , Signal-To-Noise Ratio , Image Processing, Computer-Assisted/methods
4.
J Synchrotron Radiat ; 31(Pt 4): 936-947, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38917018

ABSTRACT

X-ray and neutron scattering have long been used for structural characterization of cellulose in plants. Due to averaging over the illuminated sample volume, these measurements traditionally overlooked the compositional and morphological heterogeneity within the sample. Here, a scanning tomographic imaging method is described, using contrast derived from the X-ray scattering intensity, for virtually sectioning the sample to reveal its internal structure at a resolution of a few micrometres. This method provides a means for retrieving the local scattering signal that corresponds to any voxel within the virtual section, enabling characterization of the local structure using traditional data-analysis methods. This is accomplished through tomographic reconstruction of the spatial distribution of a handful of mathematical components identified by non-negative matrix factorization from the large dataset of X-ray scattering intensity. Joint analysis of multiple datasets, to find similarity between voxels by clustering of the decomposed data, could help elucidate systematic differences between samples, such as those expected from genetic modifications, chemical treatments or fungal decay. The spatial distribution of the microfibril angle can also be analyzed, based on the tomographically reconstructed scattering intensity as a function of the azimuthal angle.


Subject(s)
Cellulose , Cellulose/chemistry , Scattering, Radiation , X-Ray Diffraction/methods , Plants/chemistry
5.
Invest Ophthalmol Vis Sci ; 65(6): 15, 2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38848076

ABSTRACT

Purpose: The purpose of this study was to investigate the associations between visual function and severity grading, corneal scatter, or higher-order aberrations (HOAs) in patients with Fuchs endothelial corneal dystrophy (FECD). Methods: This observational case series study included 49 eyes of 27 patients with FECD and 10 eyes of 10 healthy individuals. We evaluated corrected distance visual acuity (CDVA) using Landolt-C and Early Treatment Diabetic Retinopathy Study charts and contrast sensitivity using the CSV-1000E chart and CSV-1000RN letter chart. We analyzed the associations between visual function and explanatory variables, including age, modified Krachmer grade, central corneal thickness (CCT), anterior segment optical coherence tomography (AS-OCT)-based grade, HOAs, intraocular straylight, and corneal densitometry. We additionally conducted receiver operating characteristic (ROC) analysis to identify the corneal densitometry thresholds for decreased visual function. Results: There were significant associations between visual function and the modified Krachmer grade, CCT, AS-OCT-based grade, HOAs, intraocular straylight, and corneal densitometry. A modified Krachmer grade ≥ 3 was identified as a threshold for decreased visual function. Multivariate analysis showed that corneal densitometry was significantly associated with all visual function parameters, and HOAs were significantly associated with CDVA but not with contrast sensitivity. ROC analysis revealed that corneal densitometry of the posterior layer at 0 to 2 mm ≥ 10 grayscale units (GSU), was identified as a threshold for decreased visual function. Conclusions: HOAs, forward and backward light scatter affected visual function, with backward light scatter being the most influential. In patients with FECD, modified Krachmer grade ≥ 3 and corneal densitometry ≥ 10 GSU were thresholds for visual disturbance.


Subject(s)
Contrast Sensitivity , Corneal Wavefront Aberration , Fuchs' Endothelial Dystrophy , Scattering, Radiation , Visual Acuity , Humans , Fuchs' Endothelial Dystrophy/physiopathology , Fuchs' Endothelial Dystrophy/diagnosis , Female , Male , Visual Acuity/physiology , Middle Aged , Aged , Contrast Sensitivity/physiology , Corneal Wavefront Aberration/physiopathology , Corneal Wavefront Aberration/diagnosis , Tomography, Optical Coherence/methods , Cornea/physiopathology , Cornea/diagnostic imaging , Severity of Illness Index , ROC Curve , Aged, 80 and over , Adult
6.
J Biomed Opt ; 29(6): 066005, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38841076

ABSTRACT

Significance: Damage to the cardiac conduction system remains one of the most significant risks associated with surgical interventions to correct congenital heart disease. This work demonstrates how light-scattering spectroscopy (LSS) can be used to non-destructively characterize cardiac tissue regions. Aim: To present an approach for associating tissue composition information with location-specific LSS data and further evaluate an LSS and machine learning system as a method for non-destructive tissue characterization. Approach: A custom LSS probe was used to gather spectral data from locations across 14 excised human pediatric nodal tissue samples (8 sinus nodes, 6 atrioventricular nodes). The LSS spectra were used to train linear and neural-network-based regressor models to predict tissue composition characteristics derived from the 3D models. Results: Nodal tissue region nuclear densities were reported. A linear model trained to regress nuclear density from spectra achieved a prediction r-squared of 0.64 and a concordance correlation coefficient of 0.78. Conclusions: These methods build on previous studies suggesting that LSS measurements combined with machine learning signal processing can provide clinically relevant cardiac tissue composition.


Subject(s)
Scattering, Radiation , Spectrum Analysis , Humans , Spectrum Analysis/methods , Machine Learning , Light , Heart/diagnostic imaging , Myocardium/chemistry
7.
PLoS One ; 19(6): e0304721, 2024.
Article in English | MEDLINE | ID: mdl-38843300

ABSTRACT

Accurately modeling artificial boundary conditions and wave inputs is paramount for numerical simulations of wave scattering in semi-infinite domains within seismic engineering. Traditionally, analysts focused on one- or two-dimensional free-field problems to determine wave inputs, primarily for vertically incident plane waves or obliquely incident waves parallel to two axes. However, these methods were inadequate for handling arbitrary incident directions in three-dimensional scenarios. This paper proposes a method for modeling seismic wave incidents in arbitrary directions. The basic theory of viscoelastic boundaries is leveraged, and a plane containing an arbitrary incident direction and the vertical coordinate axis is selected to establish a two-dimensional plane coordinate system. The two-dimensional free-field problem in this coordinate system is derived using the transfer matrix method. Subsequently, displacement, velocity, and stress are converted into the coordinate system where the three-dimensional calculation model is located, providing input for the three-dimensional scattering problem. Furthermore, the implementation of transmitting boundary conditions and viscoelastic boundary wave inputs is presented to enable incident wave scattering problems at any angle of the plane. The effect of oblique-incidence soil-structure dynamic interaction is also discussed, focusing on the parallel technology method adopted in this paper. With the relatively mature technology route and method, together with nuclear power systems and large-span deep-water bridge models, through examples of comparative analysis, qualitative and quantitative analyses are made on the impact on the soil mass, foundation, and structure when the seismic wave is an oblique incident.


Subject(s)
Models, Theoretical , Computer Simulation , Scattering, Radiation
8.
Nat Commun ; 15(1): 5202, 2024 Jun 19.
Article in English | MEDLINE | ID: mdl-38898004

ABSTRACT

Acoustic vibrations of matter convey fundamental viscoelastic information that can be optically retrieved by hyperfine spectral analysis of the inelastic Brillouin scattered light. Increasing evidence of the central role of the viscoelastic properties in biological processes has stimulated the rise of non-contact Brillouin microscopy, yet this method faces challenges in turbid samples due to overwhelming elastic background light. Here, we introduce a common-path Birefringence-Induced Phase Delay (BIPD) filter to disentangle the polarization states of the Brillouin and Rayleigh signals, enabling the rejection of the background light using a polarizer. We demonstrate a 65 dB extinction ratio in a single optical pass collecting Brillouin spectra in extremely scattering environments and across highly reflective interfaces. We further employ the BIPD filter to image bone tissues from a mouse model of osteopetrosis, highlighting altered biomechanical properties compared to the healthy control. Results herald new opportunities in mechanobiology where turbid biological samples remain poorly characterized.


Subject(s)
Elasticity , Animals , Birefringence , Mice , Viscosity , Biomechanical Phenomena , Bone and Bones/diagnostic imaging , Light , Scattering, Radiation
9.
J Biomed Opt ; 29(6): 060801, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38864093

ABSTRACT

Significance: The estimation of tissue optical properties using diffuse optics has found a range of applications in disease detection, therapy monitoring, and general health care. Biomarkers derived from the estimated optical absorption and scattering coefficients can reflect the underlying progression of many biological processes in tissues. Aim: Complex light-tissue interactions make it challenging to disentangle the absorption and scattering coefficients, so dedicated measurement systems are required. We aim to help readers understand the measurement principles and practical considerations needed when choosing between different estimation methods based on diffuse optics. Approach: The estimation methods can be categorized as: steady state, time domain, time frequency domain (FD), spatial domain, and spatial FD. The experimental measurements are coupled with models of light-tissue interactions, which enable inverse solutions for the absorption and scattering coefficients from the measured tissue reflectance and/or transmittance. Results: The estimation of tissue optical properties has been applied to characterize a variety of ex vivo and in vivo tissues, as well as tissue-mimicking phantoms. Choosing a specific estimation method for a certain application has to trade-off its advantages and limitations. Conclusion: Optical absorption and scattering property estimation is an increasingly important and accessible approach for medical diagnosis and health monitoring.


Subject(s)
Phantoms, Imaging , Scattering, Radiation , Humans , Light , Optical Imaging/methods , Animals , Absorption, Radiation , Algorithms
10.
Se Pu ; 42(6): 581-589, 2024 Jun.
Article in Chinese | MEDLINE | ID: mdl-38845519

ABSTRACT

Oils and fats are commonly used in the pharmaceutical industry as solvents, emulsifiers, wetting agents, and dispersants, and are an important category of pharmaceutical excipients. Fatty acids with unique compositions are important components of oil pharmaceutical excipients. The Chinese Pharmacopoeia provides clear descriptions of the fatty acid types and limits suitable for individual oil pharmaceutical excipient. An unqualified fatty acid composition or content may indicate adulteration or deterioration. The fatty acid composition, as a key indicator for the identification and adulteration evaluation of oil pharmaceutical excipients, can directly affect the quality and safety of oil pharmaceutical excipients and preparations. Gas chromatography is the most widely used technique for fatty acid analysis, but it generally requires derivatization, which affects quantitative accuracy. Supercritical fluid chromatography (SFC), an environmentally friendly technique with excellent separation capability, offers an efficient method for detecting fatty acids without derivatization. Unlike other chromatographic methods, SFC does not use nonvolatile solvents (e. g., water) as the mobile phase, rendering it compatible with an evaporative light-scattering detector (ELSD) for enhanced detection sensitivity. However, the fatty acids in oil pharmaceutical excipients exist in the free and bound forms, and the low content of free fatty acids in these oil pharmaceutical excipients not only poses challenges for their detection but also complicates the determination of characteristic fatty acid compositions and contents. Moreover, the compositions and ratios of fatty acids are influenced by environmental factors, leading to interconversion between their two forms. In this context, saponification provides a simpler and faster alternative to derivatization. Saponification degrades oils and fats by utilizing the reaction between esters and an alkaline solution, ultimately releasing the corresponding fatty acids. Because this method is more cost effective than derivatization, it is a suitable pretreatment method for the detection of fatty acids in oil pharmaceutical excipients using the SFC-ELSD approach. In this study, we employed SFC-ELSD to simultaneously determine six fatty acids, namely, myristic acid, palmitic acid, stearic acid, arachidic acid, docosanoic acid, and lignoceric acid, in oil pharmaceutical excipients. Saponification of the oil pharmaceutical excipients using sodium hydroxide methanol solution effectively avoided the bias in the determination of fatty acid species and contents caused by the interconversion of fatty acids and esters. The separation of the six fatty acids was achieved within 12 min, with good linearity within their respective mass concentration ranges. The limits of detection and quantification were 5-10 mg/L and 10-25 mg/L, respectively, and the spiked recoveries were 80.93%-111.66%. The method proved to be sensitive, reproducible, and stable, adequately meeting requirements for the analysis of fatty acids in oil pharmaceutical excipients. Finally, the analytical method was successfully applied to the determination of six fatty acids in five types of oil pharmaceutical excipients, namely, corn oil, soybean oil, coconut oil, olive oil, and peanut oil. It can be combined with principal component analysis to accurately differentiate different types of oil pharmaceutical excipients, providing technical support for the rapid identification and quality control of oil pharmaceutical excipients. Thus, the proposed method may potentially be applied to the analysis of complex systems adulterated with oil pharmaceutical excipients.


Subject(s)
Chromatography, Supercritical Fluid , Excipients , Fatty Acids , Fatty Acids/analysis , Fatty Acids/chemistry , Chromatography, Supercritical Fluid/methods , Excipients/analysis , Excipients/chemistry , Scattering, Radiation , Light , Oils/chemistry , Oils/analysis
11.
J Appl Clin Med Phys ; 25(6): e14353, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38693646

ABSTRACT

BACKGROUND: A physical scatter grid is not often used in pelvic bedside examinations. However, multiple studies regarding scatter correction software (SC SW) are available for mobile chest radiography but the results are unclear for pelvic radiography. PURPOSE: We evaluated SC SW of Fujifilm (Virtual Grid) on gridless pelvic radiographs obtained from a human Thiel-embalmed body to investigate the potential of Virtual Grid in pelvic bedside examinations. METHODS: Gridless, Virtual Grid, and physical grid pelvic radiographs of a female Thiel-embalmed body were collected with a broad range of tube loads. Different software (SW) grid ratios-6:1, 10:1, 13:1, 17:1, and 20:1-were applied on the gridless radiographs to investigate the image quality (IQ) improvement of 13 IQ criteria in a visual grading analysis (VGA) setup. RESULTS: Gridless radiograph scores are significantly lower (p < 0.001) than Virtual Grid and physical grid scores obtained with the same tube load. Virtual Grid radiographs score better than gridless radiographs obtained with a higher tube load which makes a dose reduction possible. The averaged ratings of the IQ criteria processed with different SW ratios increase with increasing SW grid ratios. However, no statistically significant differences were found between the SW grid ratios. The scores of the physical grid radiographs are higher than those of the Virtual Grid radiographs when they are obtained with the same tube load. CONCLUSION: We conclude that Virtual Grid with an SW ratio of 6:1 improves the IQ of gridless pelvic radiographs in such a manner that a dose reduction is possible. However, physical grid radiograph ratings are higher compared to those of Virtual Grid radiographs.


Subject(s)
Pelvis , Humans , Female , Pelvis/diagnostic imaging , Image Processing, Computer-Assisted/methods , Software , Scattering, Radiation , Radiographic Image Interpretation, Computer-Assisted/methods , Radiation Dosage , Phantoms, Imaging
12.
Pediatr Radiol ; 54(7): 1197-1204, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38769141

ABSTRACT

BACKGROUND: Reports comparing field lens doses between helical scans with a 40-mm detector width and axial scans with a 160-mm detector width using different computed tomography (CT) scanners are currently scarce. OBJECTIVE: To compare scatter doses for lenses between a helical scan with a 40-mm detector width and an axial scan with a 160-mm detector width when using different CT scanners in the context of pediatric chest examinations. MATERIALS AND METHODS: Two different CT machines were used: Revolution CT (GE Healthcare, Waukesha, WI) with a 256-row, 0.625-mm multidetector; and Aquilion ONE GENESIS Edition (Canon Medical Systems, Otawara, Japan) with a 320-row, 0.5-mm multidetector. Three pediatric anthropomorphic phantoms were used, with optically stimulated luminescence dosimeters (OSLDs) placed on the left and right lenses. The scatter dose values measured by the OSLDs were compared between a helical scan with a 40-mm detector width and an axial scan with a 160-mm detector width during pediatric chest CT examinations. RESULTS: Median equivalent doses for the helical and axial scans were 0.12 and 0.12 mSv/mGy for the newborn, 0.17 and 0.16 mSv/mGy for the 1-year-old, and 0.18 and 0.15 mSv/mGy for the 5-year-old, respectively, when using the Revolution CT. With the Revolution CT, no significant differences were observed in the scatter doses between helical and axial scans in the newborn and 1-year-old phantoms. However, the lens scatter dose for the helical scan was approximately 20-35% higher than that for the axial scan in the 5-year-old phantom (P<0.01). The median equivalent doses of eye lenses for the helical and axial scans were 0.12 and 0.07 mSv/mGy for the newborn, 0.07 and 0.05 mSv/mGy for the 1-year-old, and 0.14 and 0.12 mSv/mGy for the 5-year-old, respectively, when using the Aquilion ONE. With the Aquilion ONE, lens scatter doses for the helical scan were approximately 70%, 40%, and 30% higher in the newborn, 1-year-old, and 5-year-old phantoms, respectively, than those for the axial scan (P<0.01). CONCLUSIONS: When using the Aquilion ONE, lens scatter doses for the helical scan were significantly higher in all three phantoms than those for the axial scan. In contrast, when using the Revolution CT, the lens scatter dose for the helical scan was significantly higher in the 5-year-old phantom than that for the axial scan. These results suggest that although scattered doses may vary with respect to the CT scanner and body size, they are generally lower in the case of axial scans.


Subject(s)
Lens, Crystalline , Phantoms, Imaging , Radiation Dosage , Scattering, Radiation , Humans , Lens, Crystalline/diagnostic imaging , Lens, Crystalline/radiation effects , Tomography, Spiral Computed/methods , Tomography, X-Ray Computed/methods , Tomography, X-Ray Computed/instrumentation , Equipment Design , Radiometry/methods , Child , Radiation Exposure/analysis , Infant , Infant, Newborn
13.
PLoS One ; 19(5): e0304086, 2024.
Article in English | MEDLINE | ID: mdl-38771849

ABSTRACT

Recently, the first generic glucagon for injection was approved for the treatment of severe hypoglycemia. Unlike its brand name recombinant glucagon, the generic glucagon is synthetic. Since glucagon has a high propensity to form aggregates in solution, it is essential to assess the aggregation profile of the synthetic glucagon compared to the recombinant glucagon. In this study, two robust separation methods, size-exclusion chromatography (SEC-HPLC) and field-flow fractionation coupled with a multi-angle light scattering detector (FFF-MALS), were employed to characterize generic and brand glucagon aggregation in six lots (three newly released, three expired). The presence of aggregation in samples was determined from the generated chromatograms and analyzed. The study showed that both products have comparable aggregation profiles. The SEC-HPLC demonstrated that in both glucagon versions, the expired lots had a higher percentage of dimers than the newly released lots, but even at expiration, the amount was negligible (∼0.1%). The FFF-MALS method did not detect any dimers or higher molecular weight aggregates. Further evaluation of the detection limit found that FFF-MALS was unable to detect aggregates at amounts lower than 0.5% of total glucagon. The negligible amounts of dimer detected in the generic and brand glucagon indicate that both versions are physically stable and are not prone to aggregation under clinically relevant conditions.


Subject(s)
Chromatography, Gel , Glucagon , Protein Aggregates , Glucagon/chemistry , Glucagon/analysis , Chromatography, High Pressure Liquid/methods , Chromatography, Gel/methods , Scattering, Radiation , Humans , Light
14.
Invest Ophthalmol Vis Sci ; 65(5): 20, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38727692

ABSTRACT

Purpose: Vision-degrading myodesopsia (VDM) from vitreous floaters significantly degrades vision and impacts visual quality of life (VQOL), but the relationship to light scattering is poorly understood. This study compared in vitro measures of light scatter and transmission in surgically excised human vitreous to preoperative indexes of vitreous structure, visual function, and VQOL. Methods: Pure vitreous collected during vitrectomy from 8 patients with VDM had wide-angle straylight measurements and dark-field imaging, performed within 36 hours of vitrectomy. Preoperative VQOL assessment with VFQ-25, contrast sensitivity (CS) measurements with Freiburg acuity contrast testing, and quantitative ultrasonography were compared to light scattering and transmission in vitro. Results: All indices of vitreous echodensity in vivo correlated positively with straylight at 0.5° (R = 0.708 to 0.775, P = 0.049 and 0.024, respectively). Straylight mean scatter index correlated with echodensity (R = 0.71, P = 0.04) and VQOL (R = -0.82, P = 0.0075). Dark-field measures in vitro correlated with degraded CS in vivo (R = -0.69, P = 0.04). VQOL correlated with straylight mean scatter index (R = -0.823, P = 0.012). Conclusions: Increased vitreous echodensity in vivo is associated with more straylight scattering in vitro, validating ultrasonography as a clinical surrogate for light scattering. Contrast sensitivity in vivo is more degraded in the presence of dark-field scattering in vitro and VQOL is decreased in patients whose vitreous has increased light scattering. These findings could form the basis for the development of optical corrections for VDM or support new laser treatments, as well as novel pharmacotherapy.


Subject(s)
Contrast Sensitivity , Light , Scattering, Radiation , Visual Acuity , Vitrectomy , Vitreous Body , Humans , Vitreous Body/diagnostic imaging , Female , Male , Middle Aged , Visual Acuity/physiology , Contrast Sensitivity/physiology , Aged , Quality of Life , Vision Disorders/physiopathology , Adult , Ultrasonography , Eye Diseases/physiopathology , Eye Diseases/diagnostic imaging
15.
J Biomed Opt ; 29(9): 093502, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38715718

ABSTRACT

Significance: Developing stable, robust, and affordable tissue-mimicking phantoms is a prerequisite for any new clinical application within biomedical optics. To this end, a thorough understanding of the phantom structure and optical properties is paramount. Aim: We characterized the structural and optical properties of PlatSil SiliGlass phantoms using experimental and numerical approaches to examine the effects of phantom microstructure on their overall optical properties. Approach: We employed scanning electron microscope (SEM), hyperspectral imaging (HSI), and spectroscopy in combination with Mie theory modeling and inverse Monte Carlo to investigate the relationship between phantom constituent and overall phantom optical properties. Results: SEM revealed that microspheres had a broad range of sizes with average (13.47±5.98) µm and were also aggregated, which may affect overall optical properties and warrants careful preparation to minimize these effects. Spectroscopy was used to measure pigment and SiliGlass absorption coefficient in the VIS-NIR range. Size distribution was used to calculate scattering coefficients and observe the impact of phantom microstructure on scattering properties. The results were surmised in an inverse problem solution that enabled absolute determination of component volume fractions that agree with values obtained during preparation and explained experimentally observed spectral features. HSI microscopy revealed pronounced single-scattering effects that agree with single-scattering events. Conclusions: We show that knowledge of phantom microstructure enables absolute measurements of phantom constitution without prior calibration. Further, we show a connection across different length scales where knowledge of precise phantom component constitution can help understand macroscopically observable optical properties.


Subject(s)
Monte Carlo Method , Phantoms, Imaging , Microscopy, Electron, Scanning , Scattering, Radiation , Microspheres , Hyperspectral Imaging/methods , Hyperspectral Imaging/instrumentation
16.
Methods Cell Biol ; 186: 189-212, 2024.
Article in English | MEDLINE | ID: mdl-38705599

ABSTRACT

This chapter discusses the problems related to the application of conventional flow cytometers to microbiology. To address some of those limitations, the concept of spectral flow cytometry is introduced and the advantages over conventional flow cytometry for bacterial sorting are presented. We demonstrate by using ThermoFisher's Bigfoot spectral sorter where the spectral signatures of different stains for staining bacteria are demonstrated with an example of performing unmixing on spectral datasets. In addition to the Bigfoot's spectral analysis, the special biosafety features of this instrument are discussed. Utilizing these biosafety features, the sorting and patterning at the single cell level is optimized using non-pathogenic bacteria. Finally, the chapter is concluded by presenting a novel, label free, non-destructive, and rapid phenotypic method called Elastic Light Scattering (ELS) technology for identification of the patterned bacterial cells based on their unique colony scatter patterns.


Subject(s)
Bacteria , Flow Cytometry , Flow Cytometry/methods , Single-Cell Analysis/methods , Scattering, Radiation
18.
Luminescence ; 39(5): e4766, 2024 May.
Article in English | MEDLINE | ID: mdl-38785095

ABSTRACT

In this work, two validated approaches were used for estimating hydroxyzine HCl for the first time using resonance Rayleigh scattering (RRS) and spectrofluorimetric techniques. The suggested approaches relied on forming an association complex between hydroxyzine HCl and 2,4,5,7-tetraiodofluorescein (erythrosin B) reagent in an acidic media. The quenching in the fluorescence intensity of 2,4,5,7-tetraiodofluorescein by hydroxyzine at 551.5 nm (excitation = 527.5 nm) was used for determining the studied drug by the spectrofluorimetric technique. The RRS approach is based on amplifying the RRS spectrum at 348 nm upon the interaction of hydroxyzine HCl with 2,4,5,7-tetraiodofluorescein. The spectrofluorimetric methodology and the RRS methodology produced linear results within ranges of 0.15-1.5 µg ml-1 and 0.1-1.2 µg ml-1, respectively. LOD values for these methods were determined to be 0.047 µg ml-1 and 0.033 µg ml-1, respectively. The content of hydroxyzine HCl in its pharmaceutical tablet was estimated using the developed procedures with acceptable recoveries. Additionally, the application of four greenness and whiteness algorithms shows that they are superior to the previously reported method in terms of sustainability, economics, analytical performance, and practicality.


Subject(s)
Algorithms , Hydroxyzine , Spectrometry, Fluorescence , Hydroxyzine/analysis , Hydroxyzine/chemistry , Histamine Antagonists/analysis , Histamine Antagonists/chemistry , Scattering, Radiation , Erythrosine/chemistry , Erythrosine/analysis
19.
Radiol Phys Technol ; 17(2): 488-503, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38696086

ABSTRACT

We proposed a new deep learning (DL) model for accurate scatter correction in digital radiography. The proposed network featured a pixel-wise water equivalent path length (WEPL) map of subjects with diverse sizes and 3D inner structures. The proposed U-Net model comprises two concatenated modules: one for generating a WEPL map and the other for predicting scatter using the WEPL map as auxiliary information. First, 3D CT images were used as numerical phantoms for training and validation, generating observed and scattered images by Monte Carlo simulation, and WEPL maps using Siddon's algorithm. Then, we optimised the model without overfitting. Next, we validated the proposed model's performance by comparing it with other DL models. The proposed model obtained scatter-corrected images with a peak signal-to-noise ratio of 44.24 ± 2.89 dB and a structural similarity index measure of 0.9987 ± 0.0004, which were higher than other DL models. Finally, scatter fractions (SFs) were compared with other DL models using an actual phantom to confirm practicality. Among DL models, the proposed model showed the smallest deviation from measured SF values. Furthermore, using an actual radiograph containing an acrylic object, the contrast-to-noise ratio (CNR) of the proposed model and the anti-scatter grid were compared. The CNR of the images corrected using the proposed model are 16% and 82% higher than those of the raw and grid-applied images, respectively. The advantage of the proposed method is that no actual radiography system is required for collecting training dataset, as the dataset is created from CT images using Monte Carlo simulation.


Subject(s)
Deep Learning , Phantoms, Imaging , Radiographic Image Enhancement , Scattering, Radiation , Water , Radiographic Image Enhancement/methods , Monte Carlo Method , Image Processing, Computer-Assisted/methods , Humans , Tomography, X-Ray Computed , Algorithms , Signal-To-Noise Ratio , Imaging, Three-Dimensional
20.
Radiography (Lond) ; 30(4): 1125-1135, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38797045

ABSTRACT

INTRODUCTION: The conventional anti-scatter grid is widely used in X-ray radiography to reduce scattered X-rays, but it increases patient dose. Scatter-correction software offers a dose-reducing alternative by correcting for scattered X-rays without a physical grid. Grids and software correction are necessary to reduce scatter radiation and improve image quality especially for the large body parts. The scatter correction can be beneficial in situations where the use of grid is challenging. The implementation of grids and advanced software correction techniques is imperative to ensure that radiographic images maintain high levels of clarity, contrast, and resolution, and ultimately facilitating more accurate diagnoses. This study compares image quality and radiation dose for abdomen exams using scatter correction software and physical grids. METHODS: An anthropomorphic phantom (abdomen) underwent imaging with varying fat and lean tissue layers and body mass index (BMI) configurations. Imaging parameters included 70 kVp tube voltage, 110 cm SID, and Automatic Exposure Control (AEC) both lateral and central chambers. AP abdomen X-ray projections were acquired with and without an anti-scatter grid, and scatter correction software was applied. Image quality was assessed using contrast to noise ratio (CNR) and signal to noise ratio (SNR) metrics. The tube current mAs was considered an exposure factor that affected radiation dose and was used to compare the VG software and physical grid. Radiation dose was measured using Dose Area Products (DAP). The effective dose was estimated using Monte Carlo simulation-PCXMC software. Paired t-tests were used to investigate the image quality difference between the Gridless and VG software, Gridless and PG, and VG software and PG approaches. For the DAP and effective dose, paired t-test was used to investigate the difference between VG software and PG. RESULTS: Images acquired with a grid had the highest mean CNR (71.3 ± 32) compared to Gridless (50 ± 33.8) and scatter correction software (59.3 ± 37.9). The mean SNR of the grid images was (82.7.3 ± 38.9), which is 18% higher than the scatter correction software images (70.4 ± 36.7) and 29% higher than in the Gridless images (62.9.3 ± 34). The mean DAP value was reduced by 81% when the scatter correction software was used compared to the grid (mean: 65.4 µGy.m2 and 338.2 µGy.m2, respectively) with a significant difference (p = 0.001). Scatter correction software resulted in a lower effective dose compared to physical grid use, (mean difference± SD = -0.3 ± 0.18 mSv) with a significant difference (P = 0.02). CONCLUSION: Scatter correction software reduced the radiation dose required but images employing a grid yielded higher CNR and SNR. However, the radiation dose reduction might affect the image quality to a level that impacts the diagnostic information available. Thus, further research needs to be conducted to optimise the use of the scatter correction software. IMPLICATION FOR PRACTICE: Objectively, X-ray scatter correction software might be promising in conditions where a grid cannot be applied.


Subject(s)
Phantoms, Imaging , Radiation Dosage , Radiography, Abdominal , Scattering, Radiation , Software , Humans , Radiography, Abdominal/methods , X-Rays
SELECTION OF CITATIONS