Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 6.128
1.
Sci Rep ; 14(1): 13079, 2024 06 07.
Article En | MEDLINE | ID: mdl-38844507

As patient exposure to ionizing radiation from medical imaging and its risks are continuing issues, this study aimed to evaluate DNA damage and repair markers after myocardial perfusion single-photon emission computed tomography (MPS). Thirty-two patients undergoing Tc-99m sestamibi MPS were studied. Peripheral blood was collected before radiotracer injection at rest and 60-90 min after injection. The comet assay (single-cell gel electrophoresis) was performed with peripheral blood cells to detect DNA strand breaks. Three descriptors were evaluated: the percentage of DNA in the comet tail, tail length, and tail moment (the product of DNA tail percentage and tail length). Quantitative PCR (qPCR) was performed to evaluate the expression of five genes related to signaling pathways in response to DNA damage and repair (ATM, ATR, BRCA1, CDKN1A, and XPC). Mann-Whitney's test was employed for statistical analysis; p < 0.05 was considered significant. Mean Tc-99m sestamibi dose was 15.1 mCi. After radiotracer injection, comparing post-exposure to pre-exposure samples of each of the 32 patients, no statistically significant differences of the DNA percentage in the tail, tail length or tail moment were found. qPCR revealed increased expression of BRCA1 and XPC, without any significant difference regarding the other genes. No significant increase in DNA strand breaks was detected after a single radiotracer injection for MPS. There was activation of only two repair genes, which may indicate that, in the current patient sample, the effects of ionizing radiation on the DNA were not large enough to trigger intense repair responses, suggesting the absence of significant DNA damage.


DNA Damage , DNA Repair , Tomography, Emission-Computed, Single-Photon , Humans , Female , Male , Tomography, Emission-Computed, Single-Photon/methods , DNA Repair/genetics , Middle Aged , Aged , Technetium Tc 99m Sestamibi , Myocardial Perfusion Imaging/methods , BRCA1 Protein/genetics , Comet Assay
2.
Front Endocrinol (Lausanne) ; 15: 1258233, 2024.
Article En | MEDLINE | ID: mdl-38841301

Technetium-99m sestamibi single-photon emission computed tomography/computed tomography (99mTc-sestamibi SPECT/CT) is a mainstay of the pre-operative localization of parathyroid lesions. We report here the case of a 30 year-old woman with a fortuitously discovered 2 cm cervical mass for which a parathyroid origin was originally suspected due to its retro-thyroidal localization and a personal history of nephrolithiasis. Normal serum calcium and parathyroid hormone (PTH) levels excluded primary hyperparathyroidism, raising suspicion of a non-functional parathyroid adenoma, and SPECT/CT imaging showed that the mass was 99mTc-sestamibi-avid. Fine-needle aspiration (FNA) was performed; cytology was non-diagnostic but the needle washout was negative for thyroglobulin, calcitonin and PTH, arguing against a thyroidal or parathyroidal origin of the mass. Core needle biopsy revealed a schwannoma, ostensibly originating from the recurrent laryngeal nerve; upon surgical resection, it was finally found to arise from the esophageal submucosa. This case illustrates the fact that endocrinologists, radiologists, nuclear medicine, head and neck, and other specialists investigating patients with cervical masses should be aware that schwannomas need to be considered in the differential diagnosis of focal 99mTc-sestamibi uptake in the neck region.


Adenoma , Neurilemmoma , Parathyroid Neoplasms , Technetium Tc 99m Sestamibi , Humans , Female , Parathyroid Neoplasms/diagnostic imaging , Parathyroid Neoplasms/pathology , Parathyroid Neoplasms/surgery , Parathyroid Neoplasms/diagnosis , Adult , Neurilemmoma/diagnostic imaging , Neurilemmoma/pathology , Neurilemmoma/diagnosis , Diagnosis, Differential , Adenoma/diagnostic imaging , Adenoma/diagnosis , Adenoma/pathology , Adenoma/metabolism , Esophageal Neoplasms/diagnostic imaging , Esophageal Neoplasms/diagnosis , Esophageal Neoplasms/pathology , Esophageal Neoplasms/surgery , Single Photon Emission Computed Tomography Computed Tomography , Radiopharmaceuticals
3.
Radiol Imaging Cancer ; 6(4): e230186, 2024 Jun.
Article En | MEDLINE | ID: mdl-38847615

Purpose To develop a molecular breast imaging (MBI)-guided biopsy system using dual-detector MBI and to perform initial testing in participants. Materials and Methods The Stereo Navigator MBI Accessory biopsy system comprises a lower detector, upper fenestrated compression paddle, and upper detector. The upper detector retracts, allowing craniocaudal, oblique, or medial or lateral biopsy approaches. The compression paddle allows insertion of a needle guide and needle. Lesion depth is calculated by triangulation of lesion location on the upper detector at 0° and 15° and relative lesion activity on upper and lower detectors. In a prospective study (July 2022-June 2023), participants with Breast Imaging Reporting and Data System category 2, 3, 4, or 5 breast lesions underwent MBI-guided biopsy. After injection of 740 MBq technetium 99m sestamibi, craniocaudal and mediolateral oblique MBI (2-minute acquisition per view) confirmed lesion visualization. A region of interest over the lesion permitted depth calculation in the system software. Upper detector retraction allowed biopsy device placement. Specimen images were obtained on the retracted upper detector, confirming sampling of the target. Results Of 21 participants enrolled (mean age, 50.6 years ± 10.1 [SD]; 21 [100%] women), 17 underwent MBI-guided biopsy with concordant pathology. No lesion was observed at the time of biopsy in four participants. Average lesion size was 17 mm (range, 6-38 mm). Average procedure time, including preprocedure imaging, was 55 minutes ± 13 (range, 38-90 minutes). Pathology results included invasive ductal carcinoma (n = 1), fibroadenoma (n = 4), pseudoangiomatous stromal hyperplasia (n = 6), and fibrocystic changes (n = 6). Conclusion MBI-guided biopsy using a dual-head system with retractable upper detector head was feasible, well tolerated, and efficient. Keywords: Breast Biopsy, Molecular Breast Imaging, Image-guided Biopsy, Molecular Breast Imaging-guided Biopsy, Breast Cancer Clinical trial registration no. NCT06058650 © RSNA, 2024.


Breast Neoplasms , Image-Guided Biopsy , Molecular Imaging , Technetium Tc 99m Sestamibi , Humans , Female , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/pathology , Middle Aged , Prospective Studies , Image-Guided Biopsy/methods , Image-Guided Biopsy/instrumentation , Adult , Molecular Imaging/methods , Molecular Imaging/instrumentation , Aged , Radiopharmaceuticals , Breast/diagnostic imaging
4.
Medicine (Baltimore) ; 103(18): e38107, 2024 May 03.
Article En | MEDLINE | ID: mdl-38701245

RATIONALE: Primary hyperparathyroidism, though relatively prevalent among endocrine disorders, affecting 1% of the general population, often presents diagnostic challenges. Given its potential to precipitate severe complications including nephrolithiasis and fractures, timely diagnosis, and effective management are crucial. PATIENT CONCERNS: A 38-year-old woman with hypercalcemia was referred to the Department of Nuclear Medicine for a Tc-99m MIBI scan. DIAGNOSES: Tc-99m MIBI scan showed focal increased uptake in the left thyroid gland area, initially suggesting a parathyroid adenoma. Further examination using SPECT/CT revealed a nodular lesion within the left thyroid gland showing high Tc-99m MIBI uptake. INTERVENTIONS: Left thyroid lumpectomy confirmed the lesion as follicular thyroid carcinoma. On the second Tc-99m MIBI scan conducted after total thyroidectomy, a parathyroid adenoma was eventually detected in the right lower area, enabling the subsequent appropriate treatment, a right lower parathyroidectomy. OUTCOMES: Thirteen days after the parathyroidectomy, serum levels of total calcium and parathyroid hormone returned to normal. Furthermore, bone mineral density evaluated using DEXA remained within the expected range for her age even after 14 months. LESSONS: When interpreting the Tc-99m MIBI scan, it is essential to keep in mind that various tumors rich in mitochondria, such as thyroid carcinoma, could show a high uptake of Tc-99m MIBI.


Adenocarcinoma, Follicular , Incidental Findings , Parathyroid Neoplasms , Technetium Tc 99m Sestamibi , Humans , Female , Adult , Parathyroid Neoplasms/diagnostic imaging , Parathyroid Neoplasms/surgery , Parathyroid Neoplasms/diagnosis , Adenocarcinoma, Follicular/diagnostic imaging , Adenocarcinoma, Follicular/diagnosis , Adenocarcinoma, Follicular/surgery , Diagnosis, Differential , Thyroid Neoplasms/diagnostic imaging , Thyroid Neoplasms/diagnosis , Radiopharmaceuticals , Adenoma/diagnostic imaging , Adenoma/diagnosis , Adenoma/surgery , Single Photon Emission Computed Tomography Computed Tomography/methods
5.
J Nippon Med Sch ; 91(2): 227-232, 2024.
Article En | MEDLINE | ID: mdl-38777783

BACKGROUND: Detective flow imaging (DFI) is a new imaging technology that displays low-velocity blood flow, which is difficult to visualize on conventional color Doppler ultrasonography (CDU). In this study, we compared the usefulness of DFI with that of CDU and methoxy-isobutyl-isonitrile (MIBI) scintigraphy for detecting parathyroid adenoma (PA) in patients with primary hyperparathyroidism (PHPT). METHODS: From March 2021 to March 2023, 87 PHPT patients underwent surgery, and 66 had a single PA. We performed preoperative conventional ultrasonography with CDU, MIBI scintigraphy, and DFI for 42 patients (5 males and 37 females; mean age: 61.6 ± 15.4 years). RESULTS: MIBI scintigraphy detected PA in 85.7% (36/42) patients, and both CDU and DFI detected PA in all patients. The rates of vascularity in PA detected by CDU and DFI were 71.4% (30/42) and 85.7% (36/42), respectively. Vascularity was detected by DFI in 6 patients who were negative for vascularity on MIBI scintigraphy. Furthermore, DFI detected blood supply in 6 of the 12 patients with undetectable blood supply on CDU. Fisher's exact test revealed that high or low blood flow, as determined by DFI, was significantly associated with detection of feeding vessels in PA by CDU (P < 0.001). CONCLUSIONS: DFI was useful for preoperative detection of PA blood flow.


Adenoma , Hyperparathyroidism, Primary , Parathyroid Neoplasms , Ultrasonography, Doppler, Color , Humans , Female , Male , Middle Aged , Parathyroid Neoplasms/diagnostic imaging , Parathyroid Neoplasms/surgery , Parathyroid Neoplasms/complications , Hyperparathyroidism, Primary/diagnostic imaging , Hyperparathyroidism, Primary/surgery , Aged , Ultrasonography, Doppler, Color/methods , Adenoma/diagnostic imaging , Radionuclide Imaging/methods , Technetium Tc 99m Sestamibi , Adult , Blood Flow Velocity
6.
J Cardiothorac Surg ; 19(1): 177, 2024 Apr 04.
Article En | MEDLINE | ID: mdl-38575949

BACKGROUND: Hyperparathyroidism (HPT) is a disease caused by hypersecretion of one or more parathyroid glands, it can be associated with ectopic mediastinal parathyroid glands (MEPA) in 2% of cases. The use of video-assisted thoracoscopic surgery (VATS) for the surgical resection of these glands is a safe, cost-effective, and low morbidity option for patients with MEPA. We report a case series of patients with this disease managed with VATS, the first in Mexico and Latinamerica. METHODS: From 2008 to 2022, a retrospective study involving patients with MEPA and treated by VATS approach was performed in a tertiary hospital in Mexico city. Relevant biochemical and clinical variables such as imaging studies, pre and postoperative laboratory results, surgical strategy, outcomes and pathological analysis were analyzed. RESULTS: Four cases of mediastinal parathyroid adenomas causing HPT were included. All patients were female with a median age of 52.5 years-old (range 46-59 years), half of the patients had primary HPT and the others tertiary HPT after kidney transplant. 75% of cases had a MEPA in the medium mediastinum, all had a preoperative positive SPECT-CT 99mTc Sestamibi scan. Mean preoperative PTH was 621.3pg/mL (182-1382pg/mL). All patients successfully underwent parathyroidectomy with a VATS approach, no deaths were reported. CONCLUSIONS: VATS is a minimally invasive surgery that provides adequate access to mediastinal located glands, optimal visualization of mediastinal structures and has a high resection success rate with less complications and morbidity than open approaches.


Parathyroid Neoplasms , Humans , Female , Middle Aged , Male , Parathyroid Neoplasms/diagnostic imaging , Parathyroid Neoplasms/surgery , Parathyroid Neoplasms/pathology , Mediastinum/surgery , Retrospective Studies , Parathyroid Glands/surgery , Parathyroid Glands/pathology , Parathyroidectomy/methods , Technetium Tc 99m Sestamibi
7.
Hell J Nucl Med ; 27(1): 66-67, 2024.
Article En | MEDLINE | ID: mdl-38629820

Technetium-99m-methoxy isobutyl isonitrile (99mTc-MIBI) myocardial perfusion imaging (MPI) is a functional imaging method with relatively poor specificity but high sensitivity. We present 48-year-old man with cardiac involvement due to muscular dystrophies (MD). Myocardial perfusion imaging rest images revealed regional myocardial perfusion decrease in multiple walls, enlarged heart and decreased left ventricular systolic function. The lesion location of MPI was consistent with that seen on CMR. Our case showed MPI was useful for detection and evaluation of the MD patient with cardiac involvement. In addition, imaging findings in combination with clinical history and other data are important. The case highlight is thevalue of MPI in myocardiopathy.


Muscular Dystrophies , Myocardial Perfusion Imaging , Humans , Male , Middle Aged , Muscular Dystrophies/diagnostic imaging , Muscular Dystrophies/complications , Technetium Tc 99m Sestamibi , Radiopharmaceuticals
8.
Medicine (Baltimore) ; 103(17): e37866, 2024 Apr 26.
Article En | MEDLINE | ID: mdl-38669430

To investigate the value of preoperative ultrasound combined with 99mTc-MIBI imaging for the diagnosis of ectopic intrathyroid parathyroid gland (ETPG) in patients with secondary hyperparathyroidism (SHPT). One hundred and eleven patients with SHPT who underwent total parathyroidectomy plus forearm transplantation from January 2015 to January 2022 in the Third Hospital of Hebei Medical University were selected. All patients underwent routine preoperative ultrasonography and 99mTc-MIBI imaging, and with pathological diagnosis as the gold standard, the clinical data of ETPG patients were selected, including clinical manifestations, laboratory tests, preoperative ultrasonography and 99mTc-MIBI imaging for localization and diagnosis, intraoperative exploration and postoperative pathology, and postoperative follow-up. To analyze the ultrasound manifestations of preoperative parathyroid hyperplasia and the results of 99mTc-MIBI imaging in patients with ETPG. Among 111 patients with SHPT, there were 5 patients with ETPG, 1 male and 4 females with a mean age of (45.00 ±â€…5.05) years, and 6 ectopic parathyroid glands were located in the thyroid gland. The incidence of ETPG was 4.5% (5/111), 4 were detected by ultrasound, 2 were not detected with a diagnostic accuracy of 66.7% (4/6), 3 were positive for 99mTc-MIBI imaging, 3 were negative with a diagnostic accuracy of 50.0% (3/6). Among them, one was not detected by ultrasound, but was positive for 99mTc-MIBI imaging, 2 with negative 99mTc-MIBI imaging, but all were detected by ultrasound, and one with negative 99mTc-MIBI imaging was detected by ultrasound but misdiagnosed as a thyroid nodule. A total of 5 ETPGs were detected by ultrasound combined with 99mTc-MIBI imaging, with a diagnostic accuracy of 83.3% (5/6). Patients' postoperative serum calcium and serum parathyroid hormone (PTH) levels were normalized or significantly decreased from preoperative levels. Ultrasound combined with 99mTc-MIBI imaging can achieve higher accuracy than either examination alone in the preoperative localization and diagnosis of ETPG in SHPT patients.


Choristoma , Hyperparathyroidism, Secondary , Parathyroid Glands , Technetium Tc 99m Sestamibi , Thyroid Gland , Ultrasonography , Humans , Male , Female , Hyperparathyroidism, Secondary/diagnostic imaging , Hyperparathyroidism, Secondary/surgery , Middle Aged , Parathyroid Glands/diagnostic imaging , Parathyroid Glands/surgery , Ultrasonography/methods , Adult , Choristoma/diagnostic imaging , Choristoma/complications , Thyroid Gland/diagnostic imaging , Thyroid Gland/surgery , Radiopharmaceuticals , Radionuclide Imaging/methods , Parathyroidectomy/methods
11.
Radiography (Lond) ; 30(3): 995-1000, 2024 May.
Article En | MEDLINE | ID: mdl-38688163

INTRODUCTION: Dual phase technetium-99mTc-methoxy isobutyl isonitrile (MIBI) single-photon emission computed tomography with computed tomography (SPECT/CT) may be the most accurate conventional imaging approach for localization of enlarged parathyroid gland (EPG). The imaging is based on the radiopharmaceutical (RP) retention in EPG compared to washout from normal thyroid and normal parathyroid glands. This study aimed to estimate and optimize the contribution of computed tomography (CT) scan and scan range to effective dose (ED) in dual-phase MIBI SPECT/CT parathyroid scintigraphy. METHODS: The study included seventy-four patients; thirty-seven with reduced and thirty-seven with extended CT scan range. The ED caused by the CT scan was calculated using Dose Length Product (DLP) data and estimated using the Imaging Performance Assessment of CT scanners (ImPACT) calculator. RESULTS: For all patients, the contribution of CT to the ED in a combined SPECT/CT examination was 2.62 ± 0.29 mSv (48%). The contribution of CT to the total ED was 1.8 ± 0.18 mSv (33%) when using reduced and 3.44 ± 0.23 mSv (64%) when using extended scan range. The DLP and ED were statistically significantly different between the reduced and extended CT scan range (p < 0.001) in the first and second phases. The individual organ dose was reduced from 8% to 94%. CONCLUSION: The hybrid SPECT/CT improves the interpretation of nuclear medicine images and also increases the radiation dose to the patient. An adequately defined CT scan range on SPECT/CT imaging, can significantly reduce a patient's ED. IMPLICATIONS FOR PRACTICE: The research findings showed that knowledge of anatomy, pathology and technology can provide optimising diagnostic procedures and reduce patient ED after SPECT/CT scans.


Radiation Exposure , Radiopharmaceuticals , Single Photon Emission Computed Tomography Computed Tomography , Humans , Male , Female , Middle Aged , Single Photon Emission Computed Tomography Computed Tomography/methods , Technetium Tc 99m Sestamibi , Aged , Radiation Dosage , Adult , Parathyroid Glands/diagnostic imaging , Retrospective Studies , Tomography, X-Ray Computed/methods
12.
Nucl Med Commun ; 45(7): 581-588, 2024 Jul 01.
Article En | MEDLINE | ID: mdl-38618745

OBJECTIVES: Transient ischemic dilatation (TID) in myocardial perfusion single photon emission computed tomography (SPECT) is considered a marker of poor prognosis. However, it has been suggested that some cases are due to apparent volumetric changes secondary to differences in heart rate (HR) at the time of acquisition. We assessed the correlation between transient dilatation and HR in low risk patients with no perfusion defects. METHODS: We retrospectively analyzed patients sent for 99mTc-MIBI SPECT using a 2-day protocol. We recorded the median HR during acquisition and the HR difference (HRD) between the rest and post-stress. We obtained the medium ventricular volume, end-diastolic volume (EDV), and end-systolic volume (ESV). We included patients in which TID using medium ventricular volume (TIDMV) was ≥1.2. TID was also calculated for the EDV and ESV (TIDEDV, TIDESV). We excluded patients with known coronary artery disease, perfusion defects, various ECG disorders, positive stress test, or ESV < 10 ml. RESULTS: From a total of 2006 patients, 63 (50 exercise, 13 dipyridamole) met the criteria for analysis (age 63.8 ±â€…9.7, 44 men). TIDMV was 1.29 ±â€…0.09 and HRD 9.8 beats per minute (BPM) (range -10 to 41). There was positive correlation between HRD and TIDMV ( r  = 0.51, P  < 0.001) and TIDEDV ( r  = 0.5, P  < 0.001), but not TIDESV ( r  = 0.23, P  = 0.07). Correlation was stronger when HRD was ≥10 BPM ( r  = 0.67, P  < 0.001). CONCLUSION: TID without perfusion defects should be interpreted with caution in the presence of HRD ≥ 10 BPM during post-stress acquisition.


Cardiac-Gated Single-Photon Emission Computer-Assisted Tomography , Heart Rate , Myocardial Perfusion Imaging , Humans , Male , Female , Retrospective Studies , Middle Aged , Myocardial Perfusion Imaging/methods , Aged , Myocardial Ischemia/diagnostic imaging , Myocardial Ischemia/physiopathology , Technetium Tc 99m Sestamibi
13.
Clin Nucl Med ; 49(7): 677-679, 2024 Jul 01.
Article En | MEDLINE | ID: mdl-38598494

ABSTRACT: Juxtaglomerular cell tumor or reninoma is an extremely rare, typically benign, renin-secreting tumor of the kidney that causes secondary hypertension. We describe 99m Tc-MIBI SPECT/CT findings in a case of juxtaglomerular cell tumor. The renal tumor showed isodensity and photopenia on 99m Tc-MIBI SPECT/CT. This case indicates that juxtaglomerular cell tumor can appear cold on 99m Tc-MIBI SPECT/CT, mimicking renal cell carcinoma.


Carcinoma, Renal Cell , Juxtaglomerular Apparatus , Kidney Neoplasms , Single Photon Emission Computed Tomography Computed Tomography , Technetium Tc 99m Sestamibi , Humans , Carcinoma, Renal Cell/diagnostic imaging , Kidney Neoplasms/diagnostic imaging , Diagnosis, Differential , Juxtaglomerular Apparatus/diagnostic imaging , Male , Middle Aged , Female
14.
Medicina (Kaunas) ; 60(3)2024 Mar 19.
Article En | MEDLINE | ID: mdl-38541233

Background and Objectives: Primary hyperparathyroidism (pHPT) is a common endocrine disorder caused by excessive production of parathyroid hormone (PTH) leading to elevated calcium levels. Diagnosis is primarily based on biochemical evaluation, and surgery is the curative treatment. Imaging techniques like ultrasound and Tc-99m Sestamibi scintigraphy are used for localization, but selective Internal Jugular Venous (SVS) becomes valuable in cases of inconclusive or conflicting results. This study evaluated the diagnostic efficacy of SVS for localizing parathyroid adenomas in cases where non-invasive radiological diagnostic methods yielded inconclusive results or negative findings despite clinical symptoms suggestive of pHPT. Materials and Methods: In this retrospective study, a total of 28 patients diagnosed with pHPT underwent SVS at a tertiary center known for receiving referrals from 2017 to 2022. The diagnoses were confirmed through biochemical analysis. The SVS results in 22 patients were compared with non-invasive imaging methods, including ultrasound, scintigraphy, and computed tomography with/without contrast material. SVS was indicated when at least two non-invasive diagnostic procedures failed to clearly localize the parathyroid glands or provided ambiguous results. Results: SVS demonstrated higher sensitivity for localizing parathyroid adenomas compared to non-invasive imaging methods, accurately lateralizing the adenoma in 68.18% of cases. Among the SVS findings, 31.8% of patients had negative results, with 9.1% not having clinically proven parathyroid adenoma, while 22.7% had false negative SVS findings but were later confirmed to have adenoma during surgery. Ultrasound correctly identified the location in 45.45% of cases, CT in 27.27%, and scintigraphy in 40.9%. Conclusions: SVS is a valuable diagnostic tool for accurately localizing parathyroid adenomas in patients with inconclusive non-invasive imaging results. It aids in targeted surgical interventions, contributing to improved management and treatment outcomes in primary hyperparathyroidism.


Adenoma , Hyperparathyroidism, Primary , Parathyroid Neoplasms , Humans , Parathyroid Neoplasms/complications , Parathyroid Neoplasms/diagnosis , Parathyroid Neoplasms/surgery , Hyperparathyroidism, Primary/diagnosis , Hyperparathyroidism, Primary/surgery , Retrospective Studies , Parathyroid Glands , Technetium Tc 99m Sestamibi , Adenoma/complications , Adenoma/diagnosis , Adenoma/surgery
15.
Surgery ; 175(5): 1299-1304, 2024 May.
Article En | MEDLINE | ID: mdl-38433078

BACKGROUND: Preoperative imaging before parathyroidectomy can localize adenomas and reduce unnecessary bilateral neck explorations. We hypothesized that (1) the utility of preoperative imaging varies substantially depending on the preoperative probability of having adenoma(s) and (2) that a selective imaging approach based on this probability could avoid unnecessary patient costs and radiation. METHODS: We analyzed 3,577 patients who underwent parathyroidectomy for primary hyperparathyroidism from 2001 to 2022. The predicted probability of patients having single or double adenoma versus hyperplasia was estimated using logistic regression. We then estimated the relationship between the predicted probability of single/double adenoma and the likelihood that sestamibi or 4-dimensional computed tomography was helpful for operative planning. Current Medicare costs and published data on radiation dosing were used to calculate costs and radiation exposure from non-helpful imaging. RESULTS: The mean age was 62 ± 13 years; 78% were women. Adenomas were associated with higher mean calcium (11.2 ± 0.74 mg/dL) and parathyroid hormone levels (140.6 ± 94 pg/mL) than hyperplasia (9.8 ± 0.52 mg/dL and 81.4 ± 66 pg/mL). The probability that imaging helped with operative planning increased from 12% to 65%, as the predicted probability of adenoma increased from 30% to 90%. For every 10,000 patients, a selective approach to imaging that considered the preoperative probability of having adenomas could save patients up to $3.4 million and >239,000 millisieverts of radiation. CONCLUSION: Rather than imaging all patients with primary hyperparathyroidism, a selective strategy that considers the probability of having adenomas could reduce costs and avoid excess radiation exposure.


Adenoma , Hyperparathyroidism, Primary , Parathyroid Neoplasms , United States , Humans , Female , Aged , Middle Aged , Male , Parathyroidectomy/methods , Hyperparathyroidism, Primary/diagnostic imaging , Hyperparathyroidism, Primary/surgery , Parathyroid Neoplasms/diagnostic imaging , Parathyroid Neoplasms/surgery , Technetium Tc 99m Sestamibi , Hyperplasia/diagnostic imaging , Medicare , Radiopharmaceuticals , Parathyroid Hormone , Adenoma/diagnostic imaging , Adenoma/surgery
16.
Ann Nucl Med ; 38(6): 468-474, 2024 Jun.
Article En | MEDLINE | ID: mdl-38502462

INTRODUCTION: Heterogeneous distribution in myocardial perfusion images (MPI) obtained by scintigraphy is often observed in cardiac diseases with normal myocardial perfusion. However, quantitative assessments of such heterogeneity have not been established. We hypothesized that the heterogeneity in MPI can be quantitatively evaluated through histogram analysis, calculating the standard deviation (SD), the 95% bandwidth (BW95%), and entropy. METHODS: We examined resting 99mTc-MIBI images in 20 healthy subjects and 29 patients with cardiac disease who had none or very-mild reduced myocardial perfusion evaluated as a low summed rest score (0 to 4, the range of the studied healthy subjects). Two nuclear medicine specialists blindly divided them into two groups: non-heterogeneity or heterogeneity group, based solely on their visual assessments of heterogeneity on splash and polar maps generated from single-photon emission computed tomography (SPECT) images. The %uptake was determined by dividing the tracer count of each pixel by the tracer count of the pixel with the highest value in the LV myocardium. SD, BW95%, and entropy from histogram patterns were analyzed from the polar map data array of each %uptake. We investigated whether heterogeneity could be assessed using SD, BW95, and entropy in two groups classified by visual assessments. Additionally, we evaluated the area under the curve (AUC) to identify heterogeneity in the receiver operating characteristic curve analysis. RESULTS: Based solely on visual assessments, 11 (22%) and 38 (78%) cases were classified into the non-heterogeneity and heterogeneity groups, respectively. The non-heterogeneity group consisted of only healthy subjects, and all patients with cardiac disease were classified into the heterogeneity group. The cases in the heterogeneity group had significantly higher values of heterogeneity indices (SD, BW95%, and entropy) in %uptake than those in the non-heterogeneity group (p < 0.05 for all). The AUCs of the heterogeneity indices were sufficiently high (AUCs > 0.90 for all) in distinguishing cases with visually heterogeneous distribution or patients with cardiac disease. CONCLUSIONS: Heterogeneity in MPI can be evaluated using SD, BW95%, and entropy through histogram analysis. These novel indices may help identify patients with subtle myocardial changes, even in images that show preserved perfusion (345/350).


Myocardial Perfusion Imaging , Technetium Tc 99m Sestamibi , Humans , Myocardial Perfusion Imaging/methods , Male , Female , Middle Aged , Aged , Tomography, Emission-Computed, Single-Photon , Adult , Image Processing, Computer-Assisted/methods , ROC Curve , Heart Diseases/diagnostic imaging
17.
Exp Clin Endocrinol Diabetes ; 132(4): 216-220, 2024 Apr.
Article En | MEDLINE | ID: mdl-38320618

OBJECTIVE: This study aimed to assess the diagnostic performance of 99mTc-sestamibi SPECT/CT and 18F-choline PET/CT in detecting hyperfunctioning parathyroid glands in patients undergoing surgery for primary hyperparathyroidism (PHPT). METHODS: A retrospective analysis was conducted on patients who underwent PHPT-related surgery between April 2019 and May 2022. The study focused on patients undergoing either 99mTc-sestamibi SPECT/CT (81 patients) or 18F-choline PET/CT (33 patients) scans before surgery to pinpoint hyperfunctioning parathyroid gland(s). In the majority of patients, 18F-choline PET/CT was performed after negative or inconclusive findings on 99mTc-sestamibi SPECT/CT. Pathohistological reports were utilized as the reference standard for evaluating the accuracy of the imaging findings. RESULTS: The study encompassed 83 patients (70 females, 84.3%) with an average age of 57.2 years (24-80 years). The pathohistological analysis identified a total of 98 glands. In a per-lesion analysis, the detection rate of 99mTc-sestamibi SPECT/CT was 57% (95% CI 45.3-68.1), while the detection rate of 18F-choline PET/CT was 90.3% (95% CI 74.3-98.0). CONCLUSION: The results of our study showed the significant usefulness of 18F-choline PET/CT in patients with negative or inconclusive results of 99mTc-sestamibi SPECT/CT in accurately locating hyperfunctioning parathyroid glands in PHPT patients.


Choline/analogs & derivatives , Hyperparathyroidism, Primary , Parathyroid Glands , Female , Humans , Middle Aged , Parathyroid Glands/diagnostic imaging , Parathyroid Glands/pathology , Parathyroid Glands/surgery , Positron Emission Tomography Computed Tomography/methods , Technetium Tc 99m Sestamibi , Hyperparathyroidism, Primary/diagnostic imaging , Hyperparathyroidism, Primary/surgery , Retrospective Studies , Tomography, Emission-Computed, Single-Photon
18.
Clin Nucl Med ; 49(5): 444-446, 2024 May 01.
Article En | MEDLINE | ID: mdl-38389211

ABSTRACT: A 69-year-old woman presented with a right clavicle pain. CT revealed a pathological fracture of the right clavicle, multiple osteolytic lesions, and a left cervical mass. 18 F-FDG PET/CT demonstrated a marked FDG uptake in the cervical mass and osteolytic lesions indicative of metastatic parathyroid cancer. 99m Tc-MIBI SPECT/CT revealed either faint or no uptake in the osteolytic lesions. However, a histopathological analysis after a parathyroidectomy and right clavicle biopsy confirmed the diagnosis of parathyroid cancer and the presence of benign brown tumors secondary to hyperparathyroidism. Postoperative imaging showed sclerotic change and a decreased FDG uptake in the bone lesions.


Bone Neoplasms , Osteitis Fibrosa Cystica , Parathyroid Neoplasms , Female , Humans , Aged , Fluorodeoxyglucose F18 , Parathyroid Neoplasms/complications , Positron Emission Tomography Computed Tomography/methods , Technetium Tc 99m Sestamibi , Tomography, Emission-Computed, Single-Photon , Osteitis Fibrosa Cystica/complications , Bone Neoplasms/secondary
19.
Exp Clin Transplant ; 22(Suppl 1): 96-101, 2024 Jan.
Article En | MEDLINE | ID: mdl-38385382

OBJECTIVES: Tertiary hyperparathyroidism, characterized by autonomous overproduction of parathyroid hormone, can be seen in patients with long-standing secondary hyperparathyroidism (pretransplant) or after renal transplant (posttransplant). Parathyroid scintigraphy and ultrasonography are the most commonly used imaging procedures for the preoperative localization of abnormal parathyroid glands. We aimed to evaluate imaging findings in pretransplant and posttransplant tertiary hyperparathyroidism. MATERIALS AND METHODS: This study included 32 patients with pretransplant tertiary hyperparathyroidism and 20 patients with posttransplant tertiary hyperparathyroidism. On parathyroid scintigraphy with technetium-99m sestamibi, early-phase and latephase images were acquired. Images were evaluated for the presence and the number of active foci and the degree of uptake on the late-phase image. The existence of an autonomous gland was based on latephase retention and was scored from 0 to 2 (retention score). On ultrasonography, the criteria threshold for autonomy was the maximum length of the largest gland ≥10 mm (ultrasonography score). RESULTS: On parathyroid scintigraphy, the most commonly observed pattern in the pretransplant group was positivity in ≥3 glands, and in the posttransplant group the most commonly observed pattern was positivity in 1 to 2 glands. In pretransplant and posttransplant groups, the criteria threshold for the presence of an autonomous parathyroid gland on parathyroid scintigraphy (grade 2 retention) was met in 26 (81%) and 9 (45%) patients and on ultrasonography in 25 (78%) and 10 (50%) patients, respectively. In the whole group of patients (n = 52), correlation existed between ultrasonography score and retention score. Glandular weight was correlated with both retention score and ultrasonography score. CONCLUSIONS: Higher numbers of detectable glands and the presence of parathyroid autonomy were more common in the pretransplant group. This might be explained by parathyroid gland involution after transplant. The results may also suggest that factors other than autonomy are responsible for posttransplant tertiary hyperparathyroidism.


Hyperparathyroidism, Secondary , Parathyroid Glands , Humans , Parathyroid Glands/diagnostic imaging , Hyperparathyroidism, Secondary/diagnostic imaging , Hyperparathyroidism, Secondary/etiology , Technetium Tc 99m Sestamibi , Radionuclide Imaging , Ultrasonography/methods , Radiopharmaceuticals
20.
Head Neck ; 46(7): 1788-1794, 2024 Jul.
Article En | MEDLINE | ID: mdl-38362817

BACKGROUND: Patients with nonlocalizing hyperparathyroidism pose a significant challenge to surgeons when undergoing neck exploration for parathyroidectomy. METHODS: We evaluated 536 patients that had parathyroidectomy for primary hyperparathyroidism (PHPT) from 2005 to 2018 at a single tertiary academic center, and 155 (29%) had standard nonlocalizing preoperative imaging (negative ultrasound and sestamibi scans). RESULTS: There were a total of 102 (66%) non-ectopic single adenomas in the nonlocalizing group and 325 (85%) single adenomas in the localizing group. There was no significant difference (p = 0.09) in adenoma quadrant between localizing and nonlocalizing single adenomas, but the most common location in both groups was right inferior. Patients with nonlocalizing scans were more likely to have double adenomas (21% vs. 9%, p < 0.001), ectopic glands (10% vs. 5%, p = 0.052), and multi-gland disease (13% vs. 8%, p = 0.002). CONCLUSION: Nonlocalizing PHPT patients experienced similar cure and complication rates as localizing PHPT, but required more bilateral explorations and increased operative time.


Adenoma , Hyperparathyroidism, Primary , Parathyroid Neoplasms , Parathyroidectomy , Humans , Female , Male , Middle Aged , Hyperparathyroidism, Primary/surgery , Hyperparathyroidism, Primary/diagnostic imaging , Retrospective Studies , Parathyroid Neoplasms/surgery , Parathyroid Neoplasms/diagnostic imaging , Parathyroid Neoplasms/complications , Aged , Adenoma/surgery , Adenoma/diagnostic imaging , Adenoma/pathology , Hospitals, High-Volume , Technetium Tc 99m Sestamibi , Adult , Treatment Outcome
...