Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 1.428
1.
Biomolecules ; 14(6)2024 May 30.
Article En | MEDLINE | ID: mdl-38927049

We recently reported the potential application of recombinant prothrombin activator ecarin (RAPClot™) in blood diagnostics. In a new study, we describe RAPClot™ as an additive to develop a novel blood collection prototype tube that produces the highest quality serum for accurate biochemical analyte determination. The drying process of the RAPClot™ tube generated minimal effect on the enzymatic activity of the prothrombin activator. According to the bioassays of thrombin activity and plasma clotting, γ-radiation (>25 kGy) resulted in a 30-40% loss of the enzymatic activity of the RAPClot™ tubes. However, a visual blood clotting assay revealed that the γ-radiation-sterilized RAPClot™ tubes showed a high capacity for clotting high-dose heparinized blood (8 U/mL) within 5 min. This was confirmed using Thrombelastography (TEG), indicating full clotting efficiency under anticoagulant conditions. The storage of the RAPClot™ tubes at room temperature (RT) for greater than 12 months resulted in the retention of efficient and effective clotting activity for heparinized blood in 342 s. Furthermore, the enzymatic activity of the RAPClot™ tubes sterilized with an electron-beam (EB) was significantly greater than that with γ-radiation. The EB-sterilized RAPClot™ tubes stored at RT for 251 days retained over 70% enzyme activity and clotted the heparinized blood in 340 s after 682 days. Preliminary clinical studies revealed in the two trials that 5 common analytes (K, Glu, lactate dehydrogenase (LD), Fe, and Phos) or 33 analytes determined in the second study in the γ-sterilized RAPClot™ tubes were similar to those in commercial tubes. In conclusion, the findings indicate that the novel RAPClot™ blood collection prototype tube has a significant advantage over current serum or lithium heparin plasma tubes for routine use in measuring biochemical analytes, confirming a promising application of RAPClot™ in clinical medicine.


Recombinant Proteins , Humans , Blood Coagulation/drug effects , Serum/chemistry , Serum/metabolism , Thromboplastin/metabolism , Blood Specimen Collection/methods , Thrombelastography/methods , Gamma Rays , Anticoagulants/pharmacology , Anticoagulants/chemistry
2.
J Zoo Wildl Med ; 55(2): 404-411, 2024 Jun.
Article En | MEDLINE | ID: mdl-38875196

Thromboelastography (TEG) is a hemostatic assay evaluating clot initiation time, kinetics, strength, and extent of fibrinolysis. Hemostatic assays in nonmammalian species have been less extensively studied because of lack of taxon-specific reagents and unique physiology. Hemostatic or hemorrhagic disease has been described postmortem in elasmobranchs, but antemortem detection of coagulopathies is limited in this taxon. The study aimed to establish an elasmobranch TEG protocol to improve hemostatic evaluation and facilitate advanced treatment options for animals under human care. Multiple clotting initiators were assessed for efficacy with frozen-thawed citrated plasma, fresh citrated plasma, and fresh whole citrated blood: RapidTEGTM, citrated kaolin, Reptilase®, and species brain-derived thromboplastin prepared by two different methods. Initial evaluation found plasma samples clot inconsistently, but TEG analyses using fresh whole blood consistently led to measurable TEG reactions using multiple clotting initiators. The most reliable elasmobranch TEG results were observed using citrated fresh whole blood and the RapidTEG clot initiation reagent.


Thrombelastography , Animals , Thrombelastography/veterinary , Thrombelastography/methods , Elasmobranchii/blood
3.
Front Endocrinol (Lausanne) ; 15: 1415786, 2024.
Article En | MEDLINE | ID: mdl-38883610

Objective: This study aimed to identify predictors associated with thyroid function and thromboelastograph (TEG) examination parameters and establish a nomogram for predicting the risk of subsequent pregnancy loss in recurrent pregnancy loss (RPL). Methods: In this retrospective study, we analyzed the medical records of 575 RPL patients treated at Lanzhou University Second Hospital, China, between September 2020 and December 2022, as a training cohort. We also included 272 RPL patients from Ruian People's Hospital between January 2020 and July 2022 as external validation cohort. Predictors included pre-pregnancy thyroid function and TEG examination parameters. The study outcome was pregnancy loss before 24 weeks of gestation. Variable selection was performed using least absolute shrinkage and selection operator regression and stepwise regression analyses, and the prediction model was developed using multivariable logistic regression. The study evaluated the model's performance using the area under the curve (AUC), calibration curve, and decision curve analysis. Additionally, dynamic and static nomograms were constructed to provide a visual representation of the models. Results: The predictors used to develop the model were body mass index, previous pregnancy losses, triiodothyronine, free thyroxine, thyroid stimulating hormone, lysis at 30 minutes, and estimated percent lysis which were determined by the multivariable logistic regression with the minimum Akaike information criterion of 605.1. The model demonstrated good discrimination with an AUC of 0.767 (95%CI 0.725-0.808), and the Hosmer-Lemeshow test indicated good fitness of the predicting variables with a P value of 0.491. Identically, external validation confirmed that the model exhibited good performance with an AUC of 0.738. Moreover, the clinical decision curve showed a positive net benefit in the prediction model. Meanwhile, the web version we created was easy to use. The risk stratification indicated that high-risk patients with a risk score >147.9 had a higher chance of pregnancy loss (OR=6.05, 95%CI 4.09-8.97). Conclusions: This nomogram well-predicted the risk of future pregnancy loss in RPL and can be used by clinicians to identify high-risk patients and provide a reference for pregnancy management of RPL.


Abortion, Habitual , Nomograms , Thrombelastography , Thyroid Gland , Humans , Female , Pregnancy , Abortion, Habitual/blood , Abortion, Habitual/diagnosis , Abortion, Habitual/epidemiology , Adult , Retrospective Studies , Prognosis , Thrombelastography/methods , Thyroid Gland/physiopathology , Thyroid Function Tests , China/epidemiology
4.
Pediatr Int ; 66(1): e15773, 2024.
Article En | MEDLINE | ID: mdl-38863279

BACKGROUND: Lupus anticoagulant-hypoprothrombinemia syndrome (LAHPS) is a rare disease caused by acquired factor II (FII) deficiency and lupus anticoagulant. Patients with LAHPS typically present with thrombosis and bleeding. However, little information is available on the evaluation of coagulation potential in patients with LAHPS. We examined global coagulation potentials in patients with LAHPS during the clinical course in this study. METHODS: Coagulation potentials in two pediatric patients with LAHPS were assessed by measuring clotting time (CT) and clot formation time using Ca2+-triggered rotational thromboelastometry (ROTEM), CT and maximum coagulation velocity using clot waveform analysis (CWA), and lag time and peak thrombin using the thrombin generation assay (TGA). The day of admission was defined as day 0. RESULTS: In case 1, the bleeding symptoms disappeared by day 5. However, the TGA and CWA results were markedly lower than normal, although FII activity (FII:C) returned to within the normal range by day 14. In contrast, ROTEM revealed a recovery to near-normal levels (day 14). All coagulation parameters (day 80) were within normal ranges. In case 2, coagulation potential was severely depressed until day 12, although FII:C returned to normal levels. Bleeding symptoms disappeared on day 19, and the ROTEM data revealed that the parameters were close to the normal range. The coagulation parameters in all assays were normalized on day 75. CONCLUSIONS: Recovery of coagulation potential in patients with LAHPS was slower than the recovery of FII:C. Moreover, ROTEM appeared to be clinically useful for assessing coagulation potential in patients with LAHPS.


Hypoprothrombinemias , Lupus Coagulation Inhibitor , Thrombelastography , Humans , Hypoprothrombinemias/blood , Hypoprothrombinemias/diagnosis , Lupus Coagulation Inhibitor/blood , Female , Thrombelastography/methods , Male , Child , Blood Coagulation Tests/methods , Blood Coagulation/physiology , Child, Preschool , Antiphospholipid Syndrome/blood , Antiphospholipid Syndrome/complications , Antiphospholipid Syndrome/diagnosis
5.
BMJ Case Rep ; 17(6)2024 Jun 19.
Article En | MEDLINE | ID: mdl-38901856

The risks and benefits of spinal anaesthesia must be assessed in patients with coagulation disorders. A woman in her 20s with congenital factor VII (FVII) deficiency (31%) was admitted at 38 weeks for caesarean delivery. A rotational thromboelastometry (ROTEM) analysis showed normal coagulation and spinal anaesthesia was performed safely. A repeated ROTEM analysis after haemostasis and uterine closure showed normal coagulation without fibrinolysis. No prophylactic FVII was administered, resulting in a cost savings of US$12 884. FVII level did not predict bleeding or fibrinolysis and FVII and tranexamic acid were not indicated.


Anesthesia, Obstetrical , Anesthesia, Spinal , Cesarean Section , Factor VII Deficiency , Thrombelastography , Humans , Female , Anesthesia, Spinal/methods , Thrombelastography/methods , Pregnancy , Factor VII Deficiency/complications , Factor VII Deficiency/blood , Anesthesia, Obstetrical/methods , Adult , Pregnancy Complications, Hematologic/blood
6.
Ann Clin Lab Sci ; 54(2): 246-250, 2024 Mar.
Article En | MEDLINE | ID: mdl-38802159

Von Willebrand disease (VWD) is the most common inherited bleeding disorder. It is primarily attributed to malfunctioning or deficient Von Willebrand factor (VWF). Thromboelastography (TEG) has emerged as a valuable tool for assessing coagulation dynamics and guiding transfusion therapy in bleeding patients. Given this, we present a case study of a 23-year-old pregnant female with a past medical history of type 2B VWD, wherein TEG was employed to optimize disease screening and therapy monitoring while minimizing costs and preventing complications associated with low platelet counts. This case underscores the potential utility of TEG in enhancing the care of VWD patients, particularly in unique critical settings such as pregnancy.


Thrombelastography , von Willebrand Diseases , Humans , Thrombelastography/methods , Female , von Willebrand Diseases/diagnosis , von Willebrand Diseases/blood , Pregnancy , Young Adult , von Willebrand Factor/metabolism , von Willebrand Factor/analysis , Adult
7.
Br J Anaesth ; 132(6): 1187-1189, 2024 Jun.
Article En | MEDLINE | ID: mdl-38729743

Viscoelastic haemostatic testing (VHT) has been used to determine hyperfibrinolysis and hypofibrinolysis. When modified by addition of tissue plasminogen activator (tPA), VHT has been suggested to assess responses to antifibrinolytic therapy and to estimate the concentration of tranexamic acid in patients undergoing cardiac surgery. Despite some evidence that tPA-modified VHT might allow individualisation of antifibrinolytic therapy, further studies are warranted to prove its clinical benefit for postsurgical bleeding, transfusion of blood products, and thromboembolic events.


Antifibrinolytic Agents , Humans , Antifibrinolytic Agents/therapeutic use , Postoperative Hemorrhage/prevention & control , Precision Medicine/methods , Thrombelastography/methods , Tissue Plasminogen Activator/therapeutic use , Tranexamic Acid/therapeutic use , Tranexamic Acid/administration & dosage , Treatment Outcome
8.
Article En | MEDLINE | ID: mdl-38775137

OBJECTIVE: To determine if Irish Wolfhounds (IWs), like other sighthounds, are hyperfibrinolytic compared with nonsighthound dogs using 2 native and tissue plasminogen activator (tPA)-enhanced viscoelastic assays, one that is whole blood-based (viscoelastic coagulation monitor [VCM]) and the other that is plasma-based thromboelastography (TEG). DESIGN: Cohort study. SETTING: University teaching hospital. ANIMALS: A convenience sample of 27 IWs recruited from the Irish Wolfhound Association of New England Specialty and the local community, and 27 healthy, age-matched, large-breed control dogs. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Blood samples including CBC, biochemistry, traditional coagulation, and viscoelastic testing were collected from IWs and control dogs. Twelve IWs had viscoelastic testing. IWs had lower fibrinogen concentrations (215.5 ± 57.8 vs 251.4 ± 64.5 mg/dL, P = 0.034) and formed weaker clots on both whole-blood VCM and plasma TEG assays (maximum clot firmness [VCM-MCF] = 39.4 [25.1-48.8] vs 48.5 [34.6-57.3], P = 0.0042; maximum amplitude [TEG-MA] = 22.7 [14.7-33.6] vs 32.2 [26.9-42.0], P < 0.0001). IWs were hyperfibrinolytic compared with control dogs on VCM whole-blood assays, with 25 U/mL tPA (lysis at 30 min [VCM-LI30] = 68.1 [0-100] vs\ 99.9 [63.3-100], P = 0.0009; lysis at 45 min [VCM-LI45] = 31.0 [0-100] vs 98.1 [38.4-100], P = 0.0002) but hypofibrinolytic compared with controls on TEG plasma assays with 50 U/mL tPA (lysis at 30 min [TEG-LY30] = 45.7 [4.6-94.6] vs 93.7 [12.3-96.5], P = 0.0004; lysis at 60 min [TEG-LY60] = 68.7 [29.7-96.8] vs 95.7 [34.4-97.6], P = 0.0003). Minimal fibrinolysis was measured on whole-blood VCM or plasma TEG assays without the addition of tPA, and there were no differences between the 2 groups. CONCLUSIONS: Weaker clots were found in IWs than control dogs. With the addition of tPA, IWs had evidence of hyperfibrinolysis on whole-blood VCM assays and hypofibrinolysis on plasma TEG assays compared with control dogs. Without the addition of tPA, however, both groups of dogs showed minimal fibrinolysis on viscoelastic testing.


Blood Coagulation , Fibrinolysis , Thrombelastography , Tissue Plasminogen Activator , Animals , Dogs/blood , Tissue Plasminogen Activator/blood , Fibrinolysis/drug effects , Fibrinolysis/physiology , Male , Thrombelastography/veterinary , Thrombelastography/methods , Blood Coagulation/physiology , Blood Coagulation/drug effects , Female , Blood Coagulation Tests/veterinary , Case-Control Studies , Dog Diseases/blood , Cohort Studies
9.
BMC Med Imaging ; 24(1): 115, 2024 May 18.
Article En | MEDLINE | ID: mdl-38762466

Cerebral infarction is a common neurological disease with high rates of morbidity, mortality, and recurrence, posing a great threat to human life and health. Cerebral infarction is the second leading cause of death in the world and the leading cause of long-term disability in humans. The results of the third national retrospective sampling survey on causes of death in 2008 showed that cerebral infarction has become the leading cause of death in China and its mortality rate is 4-5 times that of European and American countries. Therefore, this article proposed a study on the predictive value of Cmmi-MHR combined with thromboelastography parameters that was performed for acute cerebral infarction. This paper mainly proposed a high frame rate imaging technology and analyzed its algorithm. In this article, in the experimental part, an in-depth analysis of the predictive value of the Monocyte-to-high-density lipoprotein cholesterol ratio (MHR) combined with thromboelastography parameters was performed for acute cerebral infarction. The final experimental results showed that HDL (OR = 1.695%, P-trend = 0.049) had a probability of death within 90 days of hospitalization (OR = 0.81, 95% CI = 1.06-3.11, P-trend = 0.523). There were no significant differences in mortality rate after 90 days. Regardless of adjusting for confounders such as age, gender, and NIHSS score, there was no significant difference in the risk of MHR or monocyte count within 90 days of hospitalization. The conclusion indicates that the combination of Cmmi-MHR and thromboelastography parameters provides a new perspective and method for the diagnosis and treatment of cerebral infarction, and provides important support for personalized treatment and management of cerebral infarction.


Cerebral Infarction , Thrombelastography , Humans , Thrombelastography/methods , Cerebral Infarction/diagnostic imaging , Cerebral Infarction/blood , Cerebral Infarction/mortality , Male , Female , Middle Aged , Aged , Predictive Value of Tests , Retrospective Studies , Acute Disease , Algorithms , China/epidemiology , Aged, 80 and over
10.
Transfusion ; 64 Suppl 2: S191-S200, 2024 May.
Article En | MEDLINE | ID: mdl-38566492

INTRODUCTION: The VCM is a point-of-care analyzer using a new viscoelastometry technique for rapid assessment of hemostasis on fresh whole blood. Its characteristics would make it suitable for use in austere environments. The purpose of this study was to evaluate the VCM in terms of repeatability, reproducibility and interanalyzer correlation, reference values in our population, correlation with standard coagulation assays and platelet count, correlation with the TEG5000 analyzer and resistance to stress conditions mimicking an austere environment. METHODS: Repeatability, reproducibility, and interanalyzer correlation were performed on quality control samples (n = 10). Reference values were determined from blood donor samples (n = 60). Correlations with standard biological assays were assessed from ICU patients (n = 30) and blood donors (n = 60) samples. Correlation with the TEG5000 was assessed from blood donor samples. Evaluation of vibration resistance was performed on blood donor (n = 5) and quality control (n = 5) samples. RESULTS: The CVs for repeatability and reproducibility ranged from 0% to 11%. Interanalyzer correlation found correlation coefficients (r2) ranging from 0.927 to 0.997. Our reference values were consistent with those provided by the manufacturer. No robust correlation was found with conventional coagulation tests. The correlation with the TEG5000 was excellent with r2 ranging from 0.75 to 0.92. Resistance to stress conditions was excellent. CONCLUSION: The VCM analyzer is a reliable, easy-to-use instrument that correlates well with the TEG5000. Despite some logistical constraints, the results suggest that it can be used in austere environments. Further studies are required before its implementation.


Point-of-Care Systems , Humans , Point-of-Care Systems/standards , Reproducibility of Results , Reference Values , Thrombelastography/methods , Thrombelastography/instrumentation , Female , Male , Blood Coagulation Tests/methods , Blood Coagulation Tests/instrumentation , Blood Coagulation Tests/standards , Platelet Count/methods , Platelet Count/instrumentation , Blood Donors
11.
Transfusion ; 64 Suppl 2: S185-S190, 2024 May.
Article En | MEDLINE | ID: mdl-38587089

BACKGROUND: Thromboelastogram testing is increasingly being used to manage patients with massive bleeding. An earlier study found that the test results were influenced by the hematocrit (Hct) and platelet (PLT) concentrations. This study sought to determine if these factors confounded the results of a different manufacturer's thromboelastography testing. METHODS: Using freshly collected whole blood from volunteers and stored red blood cells (RBC) and plasma, the whole blood was manipulated to achieve different Hct values and PLT concentrations. Each reconstituted whole blood sample was tested in triplicate on the ROTEM Delta device and the ExTEM results were recorded. RESULTS: Many of the ExTEM results varied according to the Hct and PLT concentration. In particular, the ExTEM clot formation time (CFT) was abnormally long when the Hct was 45% and the PLT concentration was ≤75 × 109/L, normalizing only when the PLT count was ≥100 × 109/L. CFT samples with Hct 25% and 35% were also abnormal with low PLT concentrations but normalized at lower PLT concentrations compared to the Hct 45% samples. The ExTEM angle also demonstrated abnormal results when the Hct was 45% and the PLT concentration was ≤50 × 109/L. The ExTEM A10 and maximum clot firmness (MCF) tests tended to also be abnormal when the Hct was between 25% and 45% and the platelet concentrations were below 75 × 109/L. CONCLUSION: While thromboelastogram testing is gaining popularity for managing bleeding patients, clinicians should be aware of these confounding factors when making transfusion decisions based on their results.


Thrombelastography , Humans , Thrombelastography/methods , Hematocrit , Platelet Count , Thromboplastin/analysis , Thromboplastin/metabolism , Female , Blood Coagulation/physiology , Male
12.
Perfusion ; 39(1_suppl): 66S-76S, 2024 Apr.
Article En | MEDLINE | ID: mdl-38651578

INTRODUCTION: Extracorporeal membrane oxygenation (ECMO) may act as a driver or propagator of systemic inflammation. In turn, cytokine release can modify thromboelastographic (TEG) tests which are commonly used for anticoagulation monitoring. In this context, antithrombin (AT) supplementation might further modify TEG. METHODS: This is a pre-specified sub-study of the "Randomized Controlled Trial of Antithrombin Supplementation During Extracorporeal Membrane Oxygenation" study (investigator-initiated, randomized, single-blind, two-arm trial) conducted in two Italian ECMO referral ICUs. Adult patients requiring vv-ECMO for respiratory failure and undergoing unfractioned heparin (UFH) administration were enrolled and randomized whether to receive AT supplementation. Plasma samples for cytokine assay (IL-8, IL-10, IL-6, IL-1ß, TNF-α and Pro-ADM) and heparinase TEG were collected from every patient before ECMO start, 24 h and 72 h after ECMO start, before ECMO removal, and 7 days after ECMO removal or upon ICU discharge whichever happened first. AT concentration, coagulation and clinical data were collected before ECMO start and at pre-fixed time points. RESULTS: Thirty-nine patients were enrolled (21 treatments, 18 controls). TEG-R had a weak-to-moderate positive correlation with IL-8, IL-6, IL-10 and TNF-α and a moderate positive correlation with Pro-ADM. TEG-ANG showed a weak negative correlation with IL-8, IL-6 and TNF-α, while TEG-MA negatively correlated with IL-8, TNF-α and Pro-ADM. AT supplementation seemed to modify the association between TEG-MA and IL-8, IL-10 and Pro-ADM; conversely, AT did not affect the relationship among TEG-R or TEG-ANG and the studied cytokines. CONCLUSIONS: High concentrations of systemic cytokines correlated with longer reaction times and decreased angle and amplitude at TEG, suggesting that an increase in inflammation is related with hypocoagulability as revealed by thromboelastography.


Antithrombins , Extracorporeal Membrane Oxygenation , Inflammation , Respiratory Insufficiency , Thrombelastography , Humans , Extracorporeal Membrane Oxygenation/methods , Thrombelastography/methods , Male , Female , Antithrombins/therapeutic use , Middle Aged , Inflammation/blood , Respiratory Insufficiency/therapy , Respiratory Insufficiency/blood , Adult , Cytokines/blood , Single-Blind Method , Aged
13.
Medicine (Baltimore) ; 103(17): e37954, 2024 Apr 26.
Article En | MEDLINE | ID: mdl-38669396

To explore the value of thromboelastography (TEG) in evaluating the efficacy of Xueshuantong combined with edaravone for the treatment of acute cerebral infarction (ACI). We retrospectively analyzed the clinical data of 96 patients with ACI treated with Xueshuantong combined with edaravone and monitored by TEG. The correlation between the results of TEG examination and treatment outcomes in patients after treatment was analyzed. After treatment, 65 of 96 patients showed good efficacy and 31 had poor efficacy. kinetic time (KT), reaction time (RT), and the percentage of clot lysis at 30 minutes after Ma value (LY30) of patients with good therapeutic effects were significantly higher than those with poor therapeutic effects; However, maximum amplitude (MA) and coagulation index (CI) were significantly lower than those with poor efficacy (P < .05). There was a significant positive correlation between KT, RT, and LY30 and the therapeutic effect of ACI, and a significant negative correlation between the therapeutic effects of MA, CI, and ACI (P < .05). Logistic analysis confirmed that KT, RT, and LY30 were protective factors for the therapeutic effect of ACI; MA and CI were risk factors for the therapeutic effect of ACI (P < .05). TEG has a high value in evaluating the efficacy of Xueshuantong combined with edaravone in the treatment of ACI. It can clarify changes in the coagulation function of patients, thereby guiding clinical follow-up treatment.


Cerebral Infarction , Drugs, Chinese Herbal , Edaravone , Thrombelastography , Humans , Thrombelastography/methods , Edaravone/therapeutic use , Edaravone/pharmacology , Male , Female , Cerebral Infarction/drug therapy , Retrospective Studies , Middle Aged , Aged , Drugs, Chinese Herbal/therapeutic use , Treatment Outcome , Drug Therapy, Combination , Acute Disease , Aged, 80 and over
14.
Perfusion ; 39(1_suppl): 77S-80S, 2024 Apr.
Article En | MEDLINE | ID: mdl-38651576

PURPOSE: We aimed at assessing the correlation between TEG reaction time (TEG-R) in citrated and fresh blood samples with TEG5000 and TEG 6S during heparin administration in patients with and without ECMO support. MATERIALS AND METHODS: Paired TEG5000 (fresh and citrated whole blood, kaolin and kaolin-heparinase) and TEG6S (citrated whole blood) samples were obtained, together with standard coagulation laboratory tests. Bland-Altman analysis and Lin's concordance correlation coefficient were used to assess agreement. RESULTS: Thirteen consecutive ECMO patients and eight consecutive non-ECMO patients were enrolled and TEG was performed for a total of 84 paired samples. ECMO patients received 19.2 (12.6-25.8) U/kg/h of heparin. Five of the non-ECMO patients did not receive heparin, two of them received a very low prophylactic dose (1.6 and 2.9 IU/kg/h, respectively), and one of them 13.1 U/kg/h of heparin. Using TEG®5000, TEG-R was 21.0 (-23.4; 65.5) min longer on fresh compared to citrated blood in patients receiving heparin while only 1.58 (-5.5; 8.7) min longer in patients not-receiving heparin. These differences were reverted by heparinase. CONCLUSIONS: Using citrated-recalcified blood to perform TEG might lead to underestimation of the effect of heparin.


Extracorporeal Membrane Oxygenation , Thrombelastography , Humans , Thrombelastography/methods , Extracorporeal Membrane Oxygenation/methods , Male , Female , Middle Aged , Heparin/administration & dosage , Heparin/pharmacology , Adult , Aged
15.
Am Surg ; 90(7): 1940-1941, 2024 Jul.
Article En | MEDLINE | ID: mdl-38520264

Background: Monitoring for envenomation coagulopathy following snake bites has traditionally involved using serial coagulation studies.Purpose: Thromboelastography (TEG), with its real-time assessment, could offer an alternative to standard of care. This study aims to evaluate the use of TEG with traditional coagulation labs in the assessment of snake bite coagulopathy.Research Design: A retrospective review of patients who presented to a level 1 trauma center between 2014 and 2020 with snake bite envenomation was conducted, comparing traditional coagulation studies to TEG plus coagulation studies.Results: The 12 patients who had studies within the stipulations of our review were tracked and subsequently progressed well clinically with no adverse effects and ultimately discharged home with an average hospital stay of 2.2 days.Conclusions: Our data suggests that patients can be observed clinically without needing repeat coagulation studies if initial TEG and TCS are within normal limits.


Blood Coagulation Disorders , Snake Bites , Thrombelastography , Thrombelastography/methods , Humans , Snake Bites/complications , Retrospective Studies , Blood Coagulation Disorders/etiology , Blood Coagulation Disorders/diagnosis , Male , Female , Adult , Middle Aged , Aged , Blood Coagulation Tests
16.
Exp Physiol ; 109(6): 899-914, 2024 Jun.
Article En | MEDLINE | ID: mdl-38554124

Chronic mountain sickness is a maladaptive syndrome that affects individuals living permanently at high altitude and is characterized primarily by excessive erythrocytosis (EE). Recent results concerning the impact of EE in Andean highlanders on clotting and the possible promotion of hypercoagulability, which can lead to thrombosis, were contradictory. We assessed the coagulation profiles of Andeans highlanders with and without excessive erythrocytosis (EE+ and EE-). Blood samples were collected from 30 EE+ and 15 EE- in La Rinconada (Peru, 5100-5300 m a.s.l.), with special attention given to the sampling pre-analytical variables. Rotational thromboelastometry tests were performed at both native and normalized (40%) haematocrit using autologous platelet-poor plasma. Thrombin generation, dosages of clotting factors and inhibitors were measured in plasma samples. Data were compared between groups and with measurements performed at native haematocrit in 10 lowlanders (LL) at sea level. At native haematocrit, in all rotational thromboelastometry assays, EE+ exhibited hypocoagulable profiles (prolonged clotting time and weaker clot strength) compared with EE- and LL (all P < 0.01). At normalized haematocrit, clotting times were normalized in most individuals. Conversely, maximal clot firmness was normalized only in FIBTEM and not in EXTEM/INTEM assays, suggesting abnormal platelet activity. Thrombin generation, levels of plasma clotting factors and inhibitors, and standard coagulation assays were mostly normal in all groups. No highlanders reported a history of venous thromboembolism based on the dedicated survey. Collectively, these results indicate that EE+ do not present a hypercoagulable profile potentially favouring thrombosis.


Altitude , Blood Coagulation , Polycythemia , Thrombelastography , Thrombophilia , Humans , Polycythemia/blood , Blood Coagulation/physiology , Adult , Thrombophilia/blood , Male , Thrombelastography/methods , Female , Hematocrit/methods , Peru , Middle Aged , Altitude Sickness/blood , Altitude Sickness/physiopathology , Thrombin/metabolism
18.
Sci Rep ; 14(1): 7602, 2024 03 31.
Article En | MEDLINE | ID: mdl-38556522

Global fibrinolysis assays detect the fibrinolysis time of clot dissolution using tissue-type plasminogen activator (tPA). Two such assays, clot-fibrinolysis waveform analysis (CFWA) and global fibrinolysis capacity (GFC) assay, were recently developed. These were compared with rotational thromboelastography (ROTEM). Healthy donor blood samples were divided into four groups based on tPA-spiked concentrations: 0, 100, 500, and 1000 ng/mL. CFWA and GFC fibrinolysis times, including 4.1 µg/mL and 100 ng/mL tPA in the assays, were determined, denoted as CFWA-Lys and GFC-Lys, respectively. Statistical differences were recognized between tPA concentrations of 0 and 500/1000 ng/mL for CFWA-Lys, and 0 and 100/500/1000 ng/mL for GFC-Lys. The correlation coefficients with lysis onset time (LOT) of extrinsic pathway evaluation and intrinsic pathway evaluation in ROTEM were statistically significant at 0.610 and 0.590 for CFWA-Lys, and 0.939 and 0.928 for GFC-Lys, respectively (p-values < 0.0001 for all correlations). Both assays showed significant correlations with ROTEM; however, the GFC assay proved to have better agreement with ROTEM compared with the CFWA assay. These assays have the potential to reflect a hyperfibrinolysis status with high tPA concentrations.


Blood Coagulation Disorders , Thrombosis , Humans , Fibrinolysis , Thrombelastography/methods , Fibrin Clot Lysis Time , Tissue Plasminogen Activator/metabolism
19.
Res Vet Sci ; 171: 105205, 2024 May.
Article En | MEDLINE | ID: mdl-38479101

Sepsis/endotoxemia associates with coagulation abnormalities. We showed previously that exogenous choline treatment reversed the changes in platelet count and function as well as prevented disseminated intravascular coagulation (DIC) in endotoxemic dogs. The aim of this follow-up study was to evaluate the effect of treatment with choline or cytidine-5'-diphosphocholine (CDP-choline), a choline donor, on endotoxin-induced hemostatic alterations using thromboelastography (TEG). Dogs were randomized to six groups and received intravenously (iv) saline, choline (20 mg/kg) or CDP-choline (70 mg/kg) in the control groups, whereas endotoxin (0.1 mg/kg, iv) was used alone or in combination with choline or CDP-choline at the same doses in the treatment groups. TEG variables including R- and K-time (clot formation), maximum amplitude (MA) and α-angle (clot stability), G value (clot elasticity), and EPL, A, and LY30 (fibrinolysis), as well as overall assessment of coagulation (coagulation index - CI), were measured before and at 0.5-48 h after the treatments. TEG parameters did not change significantly in the control groups, except for CI parameter after choline administration. Endotoxemia resulted in increased R-time and A value (P < 0.05), decreased K-time (P < 0.05), α-angle (P < 0.001) and CI values (P < 0.01) at different time points. Treatment with either choline or CDP-choline attenuated or prevented completely the alterations in TEG parameters in endotoxemic dogs with CDP-choline being more effective. These results confirm and extend the effectiveness of choline or CDP-choline in endotoxemia by further demonstrating their efficacy in attenuating or preventing the altered viscoelastic properties of blood clot measured by TEG.


Choline , Cytidine Diphosphate Choline , Dog Diseases , Endotoxemia , Animals , Dogs , Choline/therapeutic use , Cytidine Diphosphate Choline/therapeutic use , Dog Diseases/drug therapy , Endotoxemia/drug therapy , Endotoxemia/veterinary , Endotoxins/adverse effects , Follow-Up Studies , Hemostatics , Thrombelastography/veterinary , Thrombelastography/methods
20.
Pediatr Crit Care Med ; 25(5): e221-e231, 2024 May 01.
Article En | MEDLINE | ID: mdl-38299935

OBJECTIVES: This study aimed to determine the test performances of rotational thromboelastometry (ROTEM) and activated partial thromboplastin time-based clot waveform analysis (aPTT-CWA) compared with the International Society on Thrombosis and Hemostasis disseminated intravascular coagulation (ISTH-DIC) score for diagnosis of overt disseminated intravascular coagulation (ODIC) in critically ill children. Prognostic indicators of DIC complications were also evaluated. DESIGN: A prospective cross-sectional observational study was conducted. ROTEM and aPTT-CWA were assessed alongside standard parameters based on the ISTH-DIC score and natural anticoagulants. Both conventional and global hemostatic tests were repeated on days 3-5 for nonovert DIC. SETTING: PICU of the Department of Pediatrics, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand. SUBJECTS: Infants and children who were admitted to PICU with underlying diseases predisposed to DIC, such as sepsis, malignancy, major surgery, trauma, or severe illness, were included in the study between July 1, 2021, and November 30, 2022. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Sixty-four children were enrolled in this study. The prevalence of ODIC was 20.3%. Regarding ROTEM parameters, using EXTEM clot formation time (CFT) cutoff of greater than 102 seconds provided sensitivity and specificity of 90.9% and 80.9%, respectively, for diagnosing ODIC, with the area under the curve (AUC) of 0.86. In the case of aPTT-CWA performance, no biphasic waveform was observed, whereas both maximum coagulation acceleration (Min2) of less than 0.35%/s 2 and maximum coagulation deceleration of less than 0.25%/s 2 demonstrated identical sensitivities of 76.9% and specificities of 79.6%. Combining two global hemostatic tests significantly improved the diagnostic performance (INTEM CFT + EXTEM CFT + Min2 AUC 0.92 [95% CI, 0.80-1.00] vs. EXTEM CFT AUC 0.86 [95% CI, 0.75-0.96], p = 0.034). Bleeding was the most common consequence. In multivariable logistic regression analysis, Min2 of less than 0.36%/s 2 was an independent risk factor for bleeding complications, with an adjusted odds ratio of 15.08 (95% CI, 1.08-211.15, p = 0.044). CONCLUSIONS: ROTEM and aPTT-CWA were valuable diagnostic tools in critically ill children who might require point-of-care tests. Min2 showed significant clinical implications for predicting bleeding events in this population.


Critical Illness , Disseminated Intravascular Coagulation , Thrombelastography , Humans , Thrombelastography/methods , Male , Prospective Studies , Female , Child, Preschool , Thailand/epidemiology , Disseminated Intravascular Coagulation/diagnosis , Child , Infant , Cross-Sectional Studies , Partial Thromboplastin Time/methods , Intensive Care Units, Pediatric , Point-of-Care Testing , Sensitivity and Specificity , Adolescent , Point-of-Care Systems , Infant, Newborn
...