1 - 20 de 2.890
1.
Lasers Med Sci ; 39(1): 154, 2024 Jun 11.
Article En | MEDLINE | ID: mdl-38862806

PURPOSE: To investigate the diagnostic ability of retinal superficial vasculature evaluation by optic coherence tomography angiography (OCTA) combined with visual field (VF) testing for early primary open-angle glaucoma (POAG). PATIENTS AND METHODS: In this cross-sectional study, 84 participants were included, including 11 in the ocular hypertension (OHT) group, 11 in the preperimetric POAG (pre-POAG) group, 29 in the early POAG group and 33 in the control group. All participants underwent 6 × 6 mm2 scans of macula and optic nerved head by optic coherence tomography (OCT) and OCTA, along with white-on-white and blue-on-yellow VF testing by static automated perimetry. The ability of diagnosing early glaucoma by either various examinations separately or combination of examinations in both terms of function and structure was studied using the receiver operating characteristic (ROC) curve and the area under the curve (AUC). RESULTS: The superficial retinal vessel densities (VD) in peri-nasal, para-temporal, peri-temporal and peri-inferior regions around the macula, as well as vessel area densities (VAD) in all peripapillary regions, were significantly different among the four groups, with lower VD or VAD in the early POAG patients compared to the normal individuals. The diagnostic ability of peripapillary superficial retinal VAD alone or VF testing alone was limited for early POAG only. However, the combination of these two was more effective in distinguishing normal individuals from OHT subjects or pre-POAG patients without VF defects, with better performance than the combination of peripapillary retinal nerve fiber layer (RNFL) thickness and VF indicators. CONCLUSIONS: Peripapillary retinal vessel densities were generally lower in early POAG patients compared to normal individuals. The combination of peripapillary superficial retinal VAD by OCTA with white-on-white VF testing improved the ability to distinguish POAG patients at early stage without function impairment, which may help in providing reference and guidance for the following-up and treatment of suspected POAG patients.


Glaucoma, Open-Angle , Microvessels , Retinal Vessels , Tomography, Optical Coherence , Visual Field Tests , Humans , Glaucoma, Open-Angle/physiopathology , Glaucoma, Open-Angle/diagnosis , Glaucoma, Open-Angle/diagnostic imaging , Cross-Sectional Studies , Male , Middle Aged , Visual Field Tests/methods , Female , Tomography, Optical Coherence/methods , Microvessels/diagnostic imaging , Retinal Vessels/diagnostic imaging , Retinal Vessels/physiopathology , Aged , ROC Curve , Visual Fields/physiology , Adult , Optic Disk/blood supply , Optic Disk/diagnostic imaging , Early Diagnosis
2.
Sci Rep ; 14(1): 12524, 2024 05 31.
Article En | MEDLINE | ID: mdl-38822030

Aim of this study was to explore the optimal training interval and times of microperimetric biofeedback training (MBFT) in maculopathies. Twenty-nine patients with maculopathies were divided into two groups: daily training (Group A) or alternate daily training (Group B). Both groups underwent 15 MBFT sessions. We compared the BCVA, reading speed, and fixation stability at baseline, after 5, 10, 15 sessions. After 15 sessions of MBFT, all visual parameters in both groups improved. There was a significant increase in BCVA after 5 sessions in both groups (P=0.016, and P<0.001 respectively), but Group A showed further improvement after 10 sessions (P<0.001). Regarding reading speed, Group A showed significant improvement from baseline after 15 sessions(P=0.020), Group B improved significantly after 5 sessions (P=0.047) and continued to improve after 10 sessions (P=0.030). Additionally, P1 and LgBCEA of Group A significantly improved after 10 sessions (P=0.001, and P=0.001 respectively), while Group B significantly improved after 5 sessions (P=0.002, and P<0.001 respectively). There was no significant difference in visual outcomes between the two groups (P>0.05) except LgBCEA (P=0.046) after 15 sessions. We concluded that the both MBFT frequencies are effective at improving vision and quality of life in patients with maculopathies. The alternate daily training group showed less time-dependent of improvement in all parameters and a greater benefit in fixation stability. Ten sessions are the optimal number of treatment sessions for alternate daily training.


Biofeedback, Psychology , Humans , Female , Male , Biofeedback, Psychology/methods , Middle Aged , Aged , Visual Acuity/physiology , Time Factors , Visual Field Tests/methods , Treatment Outcome , Adult
3.
J AAPOS ; 28(3): 103933, 2024 Jun.
Article En | MEDLINE | ID: mdl-38729256

PURPOSE: To assess the feasibility and performance of Vivid Vision Perimetry (VVP), a new virtual reality (VR)-based visual field platform. METHODS: Children 7-18 years of age with visual acuity of 20/80 or better undergoing Humphrey visual field (HVF) testing were recruited to perform VVP, a VR-based test that uses suprathreshold stimuli to test 54 field locations and calculates a fraction seen score. Pearson correlation coefficients were calculated to evaluate correlation between HVF mean sensitivity and VVP mean fraction seen scores. Participants were surveyed regarding their experience. RESULTS: A total of 37 eyes of 23 participants (average age, 12.9 ± 3.1 years; 48% female) were included. All participants successfully completed VVP testing. Diagnoses included glaucoma (12), glaucoma suspect (7), steroid-induced ocular hypertension (3), and craniopharyngioma (1). Sixteen participants had prior HVF experience, and none had prior VVP experience, although 7 had previously used VR. Of the 23 HVF tests performed, 9 (39%) were unreliable due to fixation losses, false positives, or false negatives. Similarly, 35% of VVP tests were unreliable (as defined by accuracy of blind spot detection). Excluding unreliable HVF tests, the correlation between HVF average mean sensitivity and VVP mean fraction seen score was 0.48 (P = 0.02; 95% CI, 0.09-0.74). When asked about preference for the VVP or HVF examination, all participants favored the VVP, and 70% were "very satisfied" with VVP. CONCLUSIONS: In our cohort of 23 pediatric subjects, VVP proved to be a clinically feasible VR-based visual field testing, which was uniformly preferred over HVF.


Feasibility Studies , Virtual Reality , Visual Acuity , Visual Field Tests , Visual Fields , Humans , Visual Field Tests/methods , Child , Female , Male , Pilot Projects , Adolescent , Visual Fields/physiology , Visual Acuity/physiology , Glaucoma/diagnosis , Glaucoma/physiopathology , Reproducibility of Results , Vision Disorders/diagnosis , Vision Disorders/physiopathology , Ocular Hypertension/diagnosis , Ocular Hypertension/physiopathology
4.
Retina ; 44(6): 982-990, 2024 Jun 01.
Article En | MEDLINE | ID: mdl-38767849

PURPOSE: To evaluate macular sensitivity using microperimetry in patients with proliferate diabetic retinopathy following vitrectomy and to investigate the relationship between the sensitivity and foveal microstructures with optical coherence tomography/angiography. METHODS: Eighty-four eyes of 84 patients with proliferative diabetic retinopathy, who were indicated for vitrectomy, had no intraocular surgery history 3 months preoperatively, and were able to ensure fundus examination after the vitrectomy, were included. A logMAR best-corrected visual acuity, macular sensitivity of microperimetry, macular retinal thickness, and macular vessel perfusion using optical coherence tomography/angiography were examined at 1 week, 1 month, and 3 months postoperatively. RESULTS: The logMAR best-corrected visual acuity and mean macular sensitivity of patients with proliferative diabetic retinopathy improved postoperatively (P < 0.05). There was a significant correlation between best-corrected visual acuity and mean sensitivity (P < 0.05). Postoperative mean macular sensitivity was significantly correlated with outer retinal thickness in the 0 to 6 mm macular area (P < 0.05) and also significantly correlated with deep capillary plexus perfusion (P < 0.05). Fixation stability and mean macular sensitivity did not show any correlation with glycated hemoglobin, triglyceride, serum total cholesterol, carbamide, and creatinine and duration of diabetes mellitus (P > 0.05). CONCLUSION: Postoperative mean macular sensitivity was significantly correlated with outer retinal thickness and deep capillary plexus perfusion for patients with proliferative diabetic retinopathy. The authors found that the visual performance of patients can be evaluated by the outer retinal thickness and deep capillary plexus perfusion, so optical coherence tomography/angiography examination can be an important prognostic factor for visual performance in patients.Clinical Trial Registration: This trial is registered with the Chinese Clinical Trial Registry (http://www.chictr.org.cn; Registration No.: ChiCTR2100043399).


Diabetic Retinopathy , Fluorescein Angiography , Macula Lutea , Tomography, Optical Coherence , Visual Acuity , Visual Field Tests , Vitrectomy , Humans , Diabetic Retinopathy/physiopathology , Diabetic Retinopathy/surgery , Diabetic Retinopathy/diagnosis , Vitrectomy/methods , Male , Female , Tomography, Optical Coherence/methods , Visual Acuity/physiology , Middle Aged , Visual Field Tests/methods , Fluorescein Angiography/methods , Macula Lutea/blood supply , Macula Lutea/diagnostic imaging , Aged , Adult , Visual Fields/physiology , Retinal Vessels/physiopathology , Retinal Vessels/diagnostic imaging , Postoperative Period
5.
PLoS One ; 19(5): e0303849, 2024.
Article En | MEDLINE | ID: mdl-38768185

PURPOSE: Random noise-moving images (noises) can make glaucoma patients with no subjective symptoms aware of visual field abnormalities. To explore this concept, we developed a noise using computer graphics (CG) and investigated the difference in the subjective perception of visual field abnormalities between CG and conventional analog noises. METHODS: We enrolled individuals with glaucoma (205 eyes), preperimetric glaucoma (PPG; 19 eyes), and normal eyes (35 eyes). For a CG noise, a series of still images was made by randomly selecting five monochromatic tones on 2-mm square dots, and these images were drawn at 60 frames per second (fps) to create a noise-moving image. The participants were asked to describe their perceived shadows on a paper. The results were categorized as follows based on the pattern deviation probability map of the Humphrey field analyzer (HFA): "agreement," "partial agreement," "disagreement," and "no response." The glaucoma stage was classified into four stages, from M1 to M4, based on the HFA's mean deviation. RESULT: The detection rates (agreement and partial agreement) were 80.5% and 65.4% for the CG and analog noises, respectively, with CG noise showing a significantly higher detection rate in all glaucoma eyes (P < 0.001). The detection rates tended to increase as the glaucoma stage progressed, and in Stage M3, these were 93.9% and 78.8% for the CG and analog noises, respectively. The PPG eyes did not exhibit subjective abnormalities for both noises. The specificity values were 97.1% and 100% for the CG and analog noises, respectively. CONCLUSION: The CG noise is more effective than the analog noise in evaluating the subjective perception of visual field abnormalities in patients with glaucoma.


Computer Graphics , Glaucoma , Visual Fields , Humans , Glaucoma/physiopathology , Visual Fields/physiology , Female , Male , Middle Aged , Aged , Visual Field Tests/methods , Adult , Visual Perception/physiology
6.
Vestn Oftalmol ; 140(2): 14-23, 2024.
Article Ru | MEDLINE | ID: mdl-38742494

PURPOSE: This article studies the relationship between structural changes according to the findings of optical coherence tomography (OCT) and OCT angiography (OCTA), microperimetry (MP), multifocal electroretinography (mfERG) parameters in topographically corresponding areas of the macular region in idiopathic full-thickness macular holes (FTMH). MATERIAL AND METHODS: OCT, OCTA, MP and mfERG were performed in 14 eyes with FTMH stages I-IV according to Gass. In 13 points at a distance of 0-2.5°, 2.5-5.0°, and 5.0-10.0° from the fixation point, the light sensitivity (LS), amplitude and latency of the P1 component were compared with the size of the hole, the area of cystic changes (CC) at the level of the inner nuclear layer (INL) and the outer plexiform layer and Henle fiber layer complex (OPL+HFL), vessel density in the superficial and deep capillary plexus (SCP and DCP). RESULTS: LS and P1 component amplitude were significantly reduced at a distance of up to 5.0° from the fixation point. LS correlates with the apical and basal diameter of the hole (R> -0.53), the area of CC in the INL (R> -0.62) and the OPL+HFL complex (R> -0.55), the density of vessels in the SCP at a distance of up to 2.5° from the fixation point (R>0.51) and in the DCP at a distance of up to 5° from the fixation point (R>0.49). The P1 amplitude correlates with the basal diameter of the hole (R= -0.38), the area of CC in the INL and the OPL+HFL complex (R> -0.33) and vessel density in the SCP (R=0.37) at a distance of up to 2.5° from the fixation point, as well as vessel density in the DCP at a distance of up to 5° from the fixation point (R=0.47). Vessel density in the DCP is significantly lower in the presence of CC in the retina (p<0.001). CONCLUSION: In FTMH, there is a relationship between bioelectrical activity and LS, and structural disorders, capillary perfusion in different layers of the retina. A multimodal topographically oriented approach allows studying the relationship between structural and functional parameters in individual points of the retina and can be used in monitoring of FTMH after surgical treatment.


Electroretinography , Retinal Perforations , Tomography, Optical Coherence , Humans , Tomography, Optical Coherence/methods , Retinal Perforations/physiopathology , Retinal Perforations/diagnosis , Female , Male , Electroretinography/methods , Middle Aged , Aged , Macula Lutea/diagnostic imaging , Macula Lutea/blood supply , Visual Field Tests/methods , Fluorescein Angiography/methods , Multimodal Imaging/methods
7.
Transl Vis Sci Technol ; 13(5): 10, 2024 May 01.
Article En | MEDLINE | ID: mdl-38743410

Purpose: To compare perimetric outcomes of an iPad perimetry app (Melbourne Rapid Fields [MRF]) with those of the Humphrey Field Analyser (HFA) testing children with glaucoma. Methods: Sixteen children diagnosed and treated for glaucoma were recruited to evaluate their perimetric performance over two visits. At each visit, they undertook visual field assessment using the MRF application as well as the HFA. The HFA test was part of their usual clinical work up and a clinical assistant judged which test format (24-2 SITA standard or SITA fast) might be suited to the testing of that child. The primary outcome measure was the association and repeatability of mean deviation (MD) for the MRF and HFA tests, by way of regression, intraclass correlation coefficient and Bland-Altman analysis. Secondary measures were comparisons of pattern deviation indices, test times as well as an indication of participant test preference. Summary data show means ± standard deviation. Results: The age for our cohort was 7 to 15 years of age (mean, 10.0 ± 2.4 years of age). The MRF MD was in close concordance to HFA MD with an intraclass correlation coefficient of 0.91 (95% confidence interval, 0.82-0.95). Bland-Altman analysis found little bias (-0.6 dB) and a 95% coefficient of repeatability of 2.1 dB in eyes having a normal HFA MD. In eyes with glaucomatous visual field defects the 95% coefficient of repeatability at retest was much larger for both the MRF (10.5 dB) as well as for the HFA (10.0 dB). Average MRF test times (5.6 ± 1.2 minutes) were similar to SITA Fast (5.4 ± 1.9 minutes) with both being significantly faster than SITA standard (8.6 ± 1.4 minutes; P < 0.001). All children chose testing with the MRF as their preference. Conclusions: MRF correlated strongly with HFA and was preferred by the children over the HFA. MRF is suitable for perimetric evaluation of children with glaucoma. Translational Relevance: This study finds that an iPad based visual field test can be used with children having glaucoma to yield outcomes similar to SITA-fast. Children indicate a preference for such testing.


Computers, Handheld , Glaucoma , Visual Field Tests , Visual Fields , Humans , Child , Visual Fields/physiology , Visual Field Tests/methods , Visual Field Tests/instrumentation , Male , Female , Adolescent , Glaucoma/diagnosis , Glaucoma/physiopathology , Reproducibility of Results
8.
Transl Vis Sci Technol ; 13(5): 9, 2024 May 01.
Article En | MEDLINE | ID: mdl-38743409

Purpose: To assess the diagnostic performance and structure-function association of retinal retardance (RR), a customized metric measured by a prototype polarization-sensitive optical coherence tomography (PS-OCT), across various stages of glaucoma. Methods: This cross-sectional pilot study analyzed 170 eyes from 49 healthy individuals and 68 patients with glaucoma. The patients underwent PS-OCT imaging and conventional spectral-domain optical coherence tomography (SD-OCT), as well as visual field (VF) tests. Parameters including RR and retinal nerve fiber layer thickness (RNFLT) were extracted from identical circumpapillary regions of the fundus. Glaucomatous eyes were categorized into early, moderate, or severe stages based on VF mean deviation (MD). The diagnostic performance of RR and RNFLT in discriminating glaucoma from controls was assessed using receiver operating characteristic (ROC) curves. Correlations among VF-MD, RR, and RNFLT were evaluated and compared within different groups of disease severity. Results: The diagnostic performance of both RR and RNFLT was comparable for glaucoma detection (RR AUC = 0.98, RNFLT AUC = 0.97; P = 0.553). RR showed better structure-function association with VF-MD than RNFLT (RR VF-MD = 0.68, RNFLT VF-MD = 0.58; z = 1.99; P = 0.047) in glaucoma cases, especially in severe glaucoma, where the correlation between VF-MD and RR (r = 0.73) was significantly stronger than with RNFLT (r = 0.43, z = 1.96, P = 0.050). In eyes with early and moderate glaucoma, the structure-function association was similar when using RNFLT and RR. Conclusions: RR and RNFLT have similar performance in glaucoma diagnosis. However, in patients with glaucoma especially severe glaucoma, RR showed a stronger correlation with VF test results. Further research is needed to validate RR as an indicator for severe glaucoma evaluation and to explore the benefits of using PS-OCT in clinical practice. Translational Relevance: We demonstrated that PS-OCT has the potential to evaluate the status of RNFL structural damage in eyes with severe glaucoma, which is currently challenging in clinics.


Glaucoma , Nerve Fibers , Retinal Ganglion Cells , Tomography, Optical Coherence , Visual Fields , Humans , Tomography, Optical Coherence/methods , Cross-Sectional Studies , Male , Female , Middle Aged , Nerve Fibers/pathology , Pilot Projects , Visual Fields/physiology , Glaucoma/physiopathology , Glaucoma/diagnostic imaging , Aged , Retinal Ganglion Cells/pathology , ROC Curve , Visual Field Tests/methods , Adult , Intraocular Pressure/physiology
9.
Vestn Oftalmol ; 140(2. Vyp. 2): 34-42, 2024.
Article Ru | MEDLINE | ID: mdl-38739129

PURPOSE: This study analyzes changes in light sensitivity in each test point of the visual field in patients with different stages of glaucoma. MATERIAL AND METHODS: The data of a prospective analytical case-control study were analyzed. All patients underwent assessment of retinal light sensitivity and its variability in 54 points corresponding to the 24-2 program. Mean light sensitivity values were calculated in each point. Intergroup analysis was performed to evaluate changes in light sensitivity in each point. RESULTS: The range of light sensitivity decrease in the early glaucoma group compared to the control group was from 1.5 to 3.6 dB. The range of light sensitivity decrease in the moderate glaucoma group compared to the control group was from 2.1 to 11.5 dB, and compared to the early glaucoma group - from -0.9 to 7.9 dB. The most frequent decrease in light sensitivity was detected in the nasal sector and along the horizontal line in the upper half of the visual field. This trend persisted within the central 10 degrees of the visual field. The range of light sensitivity decrease in the advanced glaucoma group compared to the control group was from 14.1 to 28.0 dB, and compared to the early glaucoma group - from 11.35 to 26.08 dB, compared to the moderate glaucoma group - from 9.1 to 23.5 dB. The most frequent and severe decrease in light sensitivity was detected in the paracentral zone in the lower half of the visual field. CONCLUSION: The study analyzed the trends in the development of glaucoma from the early to the advanced stage. The most frequent and severe defect in light sensitivity in cases of verified advanced glaucoma was found in the lower half of the visual field. Points No. 32, 33 and 40 can be indicated as the area of interest in assessing the progression of glaucoma, as they were found to have the most profound changes in light sensitivity as glaucoma progressed.


Disease Progression , Glaucoma , Visual Field Tests , Visual Fields , Humans , Visual Fields/physiology , Glaucoma/physiopathology , Glaucoma/diagnosis , Male , Female , Middle Aged , Visual Field Tests/methods , Prospective Studies , Aged , Case-Control Studies , Light
10.
Vestn Oftalmol ; 140(2. Vyp. 2): 116-122, 2024.
Article Ru | MEDLINE | ID: mdl-38739140

PURPOSE: This study assesses the light sensitivity and its variability in each point of the visual field in patients without glaucoma and with different stages of glaucoma. MATERIAL AND METHODS: The data of a prospective analytical case-control study involving 500 patients were analyzed. The initial examination of all patients was performed using basic ophthalmological methods, including static perimetry. Retinal light sensitivity and its variability were assessed in 54 points corresponding to the Humphrey 24-2 program. Mean deviation and pattern standard deviation of light sensitivity were calculated for each point. RESULTS: The lowest light sensitivity values in patients with moderate glaucoma were found in the periphery of the nasal sector, at point No. 27 - 14.4 dB, and at points No. 24-26 along the horizontal axis from the nasal side - from 17.7 to 22.7 dB. The maximum variability of light sensitivity was found in the nasal sector on both sides of the horizontal line - from 10.7 to 11.5 dB. The average light sensitivity above the horizontal axis in patients with advanced glaucoma was 10.8 dB, which is 2 dB higher than in the lower half of the visual field - 8.8 dB. The highest light sensitivity values were found at points No. 24 - 17.7 dB and No. 31 - 16.78 dB, the lowest - at point No. 32 - 4.5 dB. The average variability values of light sensitivity in the upper half of the visual field were 9.6 dB, which is 1 dB less than in the lower half of the visual field - 10.6 dB. CONCLUSION: According to our data, points No. 32 and No. 40 are of particular interest in the diagnostic plan. In these loci, the highest light sensitivity values were determined in early and moderate glaucoma. However, the values in these points decrease significantly in advanced glaucoma. It can be assumed that changes in light sensitivity in these loci at the early stages of glaucoma may be a predictor of glaucoma progression.


Glaucoma , Retina , Visual Field Tests , Visual Fields , Humans , Visual Fields/physiology , Visual Field Tests/methods , Glaucoma/physiopathology , Glaucoma/diagnosis , Middle Aged , Male , Female , Retina/physiopathology , Prospective Studies , Adult , Light , Aged , Sensory Thresholds/physiology , Case-Control Studies , Reproducibility of Results
11.
Int Ophthalmol ; 44(1): 186, 2024 Apr 20.
Article En | MEDLINE | ID: mdl-38643220

PURPOSE: This study introduces the Order of Magnitude (OM), a cost-effective, indigenous, virtual reality-based visual field analyzer designed for detecting glaucomatous visual field loss. METHODS: The OM test employs a two-step supra-thresholding algorithm utilizing stimuli of 0.43°diameter (equivalent to Goldmann size III) at low and high thresholds. A comparative analysis was conducted against the Humphrey visual field (HVF) test, considered the gold standard in clinical practice. Participants, including those with glaucoma and normal individuals, underwent comprehensive eye examinations alongside the OM and HVF tests between April and October 2019. Diagnostic sensitivity and specificity of the OM test were assessed against clinical diagnoses made by specialists. RESULTS: We studied 157 eyes (74 glaucomatous, 83 control) of 152 participants. Results demonstrated a high level of reliability for both OM and HVF tests, with no significant difference observed (P = 0.19, Chi-square test). The sensitivity and specificity of the OM test were found to be 93% (95% CI 86-100%) and 83% (95% CI 72.4-93%), respectively, while the HVF test showed sensitivity and specificity of 98% (95% CI 93.9-100%) and 83% (95% CI 73.9-92.8%), respectively. CONCLUSION: These findings suggest that the OM test is non-inferior to the reference standard HVF test in identifying glaucomatous visual field loss.


Glaucoma , Visual Fields , Humans , Reproducibility of Results , Glaucoma/diagnosis , Visual Field Tests/methods , Vision Disorders/diagnosis , Sensitivity and Specificity
12.
PLoS One ; 19(4): e0301419, 2024.
Article En | MEDLINE | ID: mdl-38573981

Perimetry, or visual field test, estimates differential light sensitivity thresholds across many locations in the visual field (e.g., 54 locations in the 24-2 grid). Recent developments have shown that an entire visual field may be relatively accurately reconstructed from measurements of a subset of these locations using a linear regression model. Here, we show that incorporating a dimensionality reduction layer can improve the robustness of this reconstruction. Specifically, we propose to use principal component analysis to transform the training dataset to a lower dimensional representation and then use this representation to reconstruct the visual field. We named our new reconstruction method the transformed-target principal component regression (TTPCR). When trained on a large dataset, our new method yielded results comparable with the original linear regression method, demonstrating that there is no underfitting associated with parameter reduction. However, when trained on a small dataset, our new method used on average 22% fewer trials to reach the same error. Our results suggest that dimensionality reduction techniques can improve the robustness of visual field testing reconstruction algorithms.


Visual Field Tests , Visual Fields , Visual Field Tests/methods , Sensory Thresholds , Algorithms , Regression Analysis
13.
BMC Ophthalmol ; 24(1): 159, 2024 Apr 10.
Article En | MEDLINE | ID: mdl-38600474

BACKGROUND: Multifocal pupillographic objective perimetry (mfPOP) is a novel method for assessing functional change in diseases like glaucoma. Previous research has suggested that, in contrast to the pretectally-mediated melanopsin response of intrinsically photosensitive retinal ganglion cells, mfPOP responses to transient onset stimuli involve the extrastriate cortex, and thus the main visual pathway. We therefore investigate the correlation between peripapillary retinal nerve fibre layer (pRNFL) thickness and glaucomatous visual field changes detected using mfPOP. Parallel analyses are undertaken using white on white standard automated perimetry (SAP) for comparison. METHODS: Twenty-five glaucoma patients and 24 normal subjects were tested using SAP, 3 mfPOP variants, and optical coherence tomography (OCT). Arcuate clusters of the SAP and mfPOP deviations were weighted according to their contribution to published arcuate divisions of the retinal nerve fibre layer. Structure-function correlation coefficients (r) were computed between pRNFL clock-hour sector thickness measurements, and the local visual field sensitivities from both SAP and mfPOP. RESULTS: The strongest correlation was observed in the superior-superotemporal disc sector in patients with worst eye SAP MD < -12 dB: r = 0.93 for the mfPOP LumBal test (p < 0.001). Correlations across all disc-sectors were strongest in these same patients in both SAP and mfPOP: SAP r = 0.54, mfPOP LumBal r = 0.55 (p < 0.001). In patients with SAP MD ≥ -6 dB in both eyes, SAP correlations across all sectors were higher than mfPOP; mfPOP correlations however, were higher than SAP in more advanced disease, and in normal subjects. CONCLUSIONS: For both methods the largest correlations with pRNFL thickness corresponded to the inferior nasal field of more severely damaged eyes. Head-to-head comparison of mfPOP and SAP showed similar structure-function relationships. This agrees with our recent reports that mfPOP primarily stimulates the cortical drive to the pupils.


Glaucoma , Visual Field Tests , Humans , Visual Field Tests/methods , Retina , Tomography, Optical Coherence/methods , Nerve Fibers , Structure-Activity Relationship
14.
Transl Vis Sci Technol ; 13(3): 10, 2024 Mar 01.
Article En | MEDLINE | ID: mdl-38488433

Purpose: Compare estimated sensitivities of SITA-Standard to the RATA-Standard algorithm of the Radius virtual reality perimeter (VRP), and measure concordance in glaucoma staging. Methods: One hundred adult glaucoma patients-half with suspect or mild glaucoma, and half with moderate or severe-from five clinics performed four 24-2 visual field tests during a single visit, two with the Humphrey Field Analyzer (HFA) and two with Radius, in randomized order: HRHR or RHRH. Only one eye was tested per participant. We used the Wilcoxon rank sum test with Bonferroni correction to compare distributions of estimated sensitivities across all 54 test locations over the 15 to 40 dB measurement range of the Radius. Weighted kappa measured concordance in glaucoma staging between two masked glaucoma experts using Medicare definitions of severity. Results: A total of 62 OD and 38 OS eyes were tested. Estimated sensitivities for SITA-Standard and RATA-Standard were not significantly different for OD, but were for OS-likely because of SITA-Standard OD and OS being significantly different in our sample, but not for RATA-Standard. Low agreement was observed between 15 to 22 dB. Concordance in glaucoma staging was high for both graders: kappa = 0.91 and kappa = 0.93. Average test duration was 298 seconds for RATA-Standard and 341 seconds for SITA-Standard. The correlation in mean deviation was 0.94. Conclusions: Estimated sensitivities of RATA-Standard are comparable to SITA-Standard between 23 to 40 dB with high concordance in glaucoma staging. Translational Relevance: Radius VRP is statistically noninferior to HFA when staging glaucoma using Medicare definitions.


Glaucoma , Virtual Reality , Wearable Electronic Devices , Aged , United States , Adult , Humans , Visual Fields , Vision Disorders , Reproducibility of Results , Medicare , Glaucoma/diagnosis , Visual Field Tests/methods
15.
Clin Exp Optom ; 107(2): 122-129, 2024 Mar.
Article En | MEDLINE | ID: mdl-38467126

Detecting deterioration of visual field sensitivity measurements is important for the diagnosis and management of glaucoma. This review surveys the current methods for assessing progression that are implemented in clinical devices, which have been used in clinical trials, alongside more recent advances proposed in the literature. Advice is also offered to clinicians on what they can do to improve the collection of perimetric data to help analytical progression methods more accurately predict change. This advice includes a discussion of how frequently visual field testing should be undertaken, with a view towards future developments, such as digital healthcare outside the standard clinical setting and more personalised approaches to perimetry.


Glaucoma , Visual Fields , Humans , Visual Field Tests/methods , Glaucoma/diagnosis , Disease Progression , Vision Disorders/diagnosis
16.
Sci Rep ; 14(1): 5116, 2024 03 01.
Article En | MEDLINE | ID: mdl-38429373

This prospective cross-sectional study investigated the visual function of preperimetric glaucoma (PPG) patients based on hemifield (HF) pattern electroretinogram (PERG) amplitudes. Thirty-two (32) normal subjects and 33 PPG patients were enrolled in control and PPG groups, respectively. All of the participants had undergone full ophthalmic examinations, including spectral-domain optical coherence tomography (SD-OCT), visual field (VF) examination and pattern electroretinography (PERG). The PERG parameters along with the HF ratios of SD-OCT and PERG were compared between the control and PPG groups. Pairwise Pearson's correlation coefficients and linear regression models were fitted to investigate the correlations. The PERG N95 amplitudes were significantly lower in the PPG group (P < 0.001). The smaller/larger HF N95 amplitude ratio of the PPG group was found to be smaller than that of the control group (0.73 ± 0.20 vs. 0.86 ± 0.12; P = 0.003) and showed positive correlations with affected HF average ganglion cell-inner plexiform layer (GCIPL) thickness (r = 0.377, P = 0.034) and with average GCIPL thickness (r = 0.341, P = 0.005). The smaller/larger HF N95 amplitude ratio did not significantly change with age (ß = - 0.005, P = 0.195), whereas the full-field N95 amplitude showed a negative correlation with age (ß = - 0.081, P < 0.001). HF analysis of PERG N95 amplitudes might be particularly useful for patients with early glaucoma.


Electroretinography , Glaucoma , Humans , Electroretinography/methods , Cross-Sectional Studies , Prospective Studies , Visual Field Tests/methods , Glaucoma/diagnostic imaging , Tomography, Optical Coherence/methods
17.
Arch. Soc. Esp. Oftalmol ; 99(3): 91-97, Mar. 2024. tab, ilus
Article Es | IBECS | ID: ibc-231135

Detectar y caracterizar los defectos del campo visual (CV) mediante perimetría Octopus en pacientes con glaucoma congénito primario (GCP) y determinar la calidad y duración del CV. Material y métodos: Se incluyeron 88 ojos de 70 pacientes diagnosticados de GCP. Las evaluaciones se realizaron con un Octopus 900 y cada ojo se evaluó con el algoritmo de perimetría orientada por tendencias (G-TOP). Se recogieron datos cuantitativos de CV: datos de calidad (respuestas falsa positiva y negativa, y duración del tiempo) y resultados de desviación media (DM) y raíz cuadrada de la varianza de pérdida (sLV). También se recogieron datos cualitativos: presencia de defectos difusos y localizados, hemicampo afectado y grado de defectos utilizando la clasificación de Aulhorn y Karmeyer. Se analizaron las correlaciones entre los resultados perimétricos y las variables clínicas. Resultados: La mediana de edad fue de 11 (8-17) años. El 65,9% (58/88) de los ojos con GCP presentaban defectos de CV. Se observaron defectos difusos en 10/58 ojos (16,94%) (DM media=23,92 [DE: 2,52]) dB) y defectos localizados en 48/58 ojos (82,75%). El defecto más frecuente fue el escotoma incipiente paracentral (n=15), el escalón nasal (n=8), el defecto arciforme añadido (n=2), el semianular (n=13) y el defecto concéntrico con isla central (n=9). El hemicampo visual afectado con mayor frecuencia fue el inferior. La duración media de la prueba fue de 2min 12s (DE: 21,6s). Los valores MD y sLV se correlacionaron con la agudeza visual mejor corregida, la relación excavación/disco y el número de cirugías de glaucoma (todas p<0,001). Conclusión: Se identificó un alto número de defectos difusos y localizados utilizando la perimetría Octopus en pacientes con GCP. El defecto más frecuente fue el escotoma paracentral, y el hemicampo inferior fue el más afectado.(AU)


Purpose: To detect and characterise visual field (VF) defects using static Octopus perimetry in patients with primary congenital glaucoma (PCG) and to determine VF quality and time duration. Material and methods: Eighty-eight eyes of 70 patients diagnosed with PCG were included. Assessments were performed using an Octopus 900 and each eye was assessed with the tendency-oriented perimetry (G-TOP) algorithm. Quantitative VF data were collected: quality data (false positive and negative response, and time duration) and results of mean deviation (MD) and square root of loss variance (sLV). Qualitative data were collected: the presence of diffuse and localized defects, the affected hemifield and grade of defects using the Aulhorn and Karmeyer classification. Correlations between perimetric results and clinical variables were analysed. ResultsMedian age was 11 (8-17) years. 65.9% (58/88) of PCG eyes showed VF defects. Diffuse defects were observed in 10/58 eyes (16.94%) (mean MD=23.92 [SD: 2.52]) dB) and localized defects in 48/58 eyes (82.75%). The most frequent defect was spot-like/stroke-like/incipient paracentral scotoma (n=15), nasal step (n=8), adding arcuate defect (n=2), half ring-shaped (n=13) and concentric defect with a central island (n=9). And the most frequent affected visual hemifield was inferior hemifield. Mean test duration was 2min 12s (SD: 21.6s). MD and sLV values were correlated with best corrected visual acuity (BCVA), cup to disc ratio and number of antiglaucoma surgeries (all P<.001). Conclusion: A high number of diffuse and localized defects were identified using Octopus perimetry in PCG patients. The most frequent defect was paracentral scotoma and inferior hemifield was the most affected.(AU)


Humans , Male , Female , Child , Glaucoma , Visual Field Tests/methods , Blindness , Eye Abnormalities , Ophthalmology , Pediatrics , Vision, Ocular
18.
Sci Rep ; 14(1): 2793, 2024 02 02.
Article En | MEDLINE | ID: mdl-38307956

This study aimed to investigate how the extent and central/peripheral location of the residual visual field (VF) in patients with late-stage inherited retinal diseases (IRDs) are related to retinal sensitivity detected using full-field stimulus testing (FST). We reviewed the results of Goldmann perimetry and FST from the medical records of patients with IRDs whose VF represents central (within 10°) and/or peripheral islands, or undetectable. In total, 19 patients (19 eyes) were analyzed in this study. The median value of residual VF area was 1.38%. The median values of rod and cone sensitivities were - 14.9 dB and 7.4 dB, respectively. Patients with only the peripheral island (- 33.9 dB) had better median rod sensitivity than other groups (only central, - 18.9 dB; both, - 3.6 dB). VF area significantly correlated with rod sensitivity (r = - 0.943, p = 0.005) in patients with only peripheral island, but not with cone sensitivity. Peripheral VF islands were significant contributors to FST results, especially rod sensitivity. With reduced or loss of central vision, the extent of residual peripheral VF significantly affected rod sensitivity, suggesting that FST can be useful in quantitatively estimating the overall remaining vision in patients with late-stage IRD.


Retinal Degeneration , Visual Fields , Humans , Visual Field Tests/methods , Dark Adaptation , Retina
19.
Turk J Ophthalmol ; 54(1): 11-16, 2024 Feb 22.
Article En | MEDLINE | ID: mdl-38385315

Objectives: To evaluate the use of the Amsler grid test (AGT) in screening for age-related macular degeneration (AMD), one of the most common causes of blindness, in primary healthcare settings. Materials and Methods: The AGT was applied to 700 eyes of 355 people aged 50 and over who applied to a family health center in Ankara and had no eye complaints. The test was considered positive if the lines on the AGT card were seen as broken or curved, there was a difference in shape or size between the squares, or a color change or blurring was described in any area. An ophthalmologist was consulted if the AGT was positive in one or both eyes. Patients considered suitable by ophthalmologists were evaluated with optical coherence tomography. AGT results were compared with ophthalmologist examination and tomography findings in terms of AMD detection. Results: The AGT was positive in 97 (13.9%) and negative in 603 (86.1%) out of 700 eyes included in the study. A total of 184 eyes, 79 with a positive AGT and 105 eyes with a negative test, were evaluated by an ophthalmologist. As a result of examinations and tests performed by ophthalmologists, AMD was detected in a total of 67 eyes: 42 of 79 eyes with positive AGT and 25 of 105 eyes with negative AGT but referred to an ophthalmologist for different reasons. In our study, the AGT had 62.7% sensitivity and 68.4% specificity. Conclusion: The AGT is an inexpensive and easily applicable test. Although moderate sensitivity and specificity were found in our study; further studies are needed to evaluate the suitability of its use for AMD screening in primary care with limited facilities.


Macular Degeneration , Visual Field Tests , Humans , Middle Aged , Aged , Visual Acuity , Visual Field Tests/methods , Macular Degeneration/diagnosis , Sensitivity and Specificity , Tomography, Optical Coherence
20.
Transl Vis Sci Technol ; 13(2): 2, 2024 02 01.
Article En | MEDLINE | ID: mdl-38306105

Purpose: To predict Humphrey Field Analyzer 24-2 test (HFA 24-2) results using 10-2 results. Methods: A total of 175 advanced glaucoma eyes (175 patients) with HFA 24-2 mean deviation (MD24-2) of < -20 dB were prospectively followed up for five years using HFA 10-2 and 24-2 (twice and once in a year, respectively). Using all the HFA 24-2 and 10-2 test result pairs measured within three months (350 pairs from 85 eyes, training dataset), a formula to predict HFA 24-2 result using HFA 10-2 results was constructed using least absolute shrinkage and selection operator regression (LASSO). Using 90 different eyes (testing dataset), the absolute differences between the actual and LASSO-predicted MD24-2 and that between the slopes calculated using five actual and LASSO-predicted MD24-2 values, were adopted as the prediction error. Similar analyses were performed for the mean total deviation values (mTD) of the superior (or inferior) hemifield [hemi-mTDsup.24-2(-hemi-mTDinf.24-2)]. Results: The prediction error for the LASSO-predicted MD24-2 and its slope were 2.98 (standard deviation [SD] = 1.90) dB and 0.32 (0.33) dB/yr, respectively. The LASSO-predicted hemi-mTDsup.24-2 (hemi-mTDinf.24-2), and its slope were 3.02 (2.89) and 3.76 (2.72) dB, and 0.37 (0.41) and 0.44 (0.38) dB/year, respectively. These prediction errors were within two times SD of repeatability of the simulated stable HFA 24-2 VF parameter series. Conclusions: HFA 24-2 results could be predicted using the paired HFA 10-2 results with reasonable accuracy using LASSO in patients with advanced glaucoma. Translational Relevance: It is useful to predict HFA24-2 test from HFA10-2 test, when the former is not available, in advanced glaucoma.


Glaucoma , Visual Fields , Humans , Visual Field Tests/methods , Glaucoma/diagnosis , Eye
...