Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 5.868
1.
Cancer Imaging ; 24(1): 57, 2024 May 06.
Article En | MEDLINE | ID: mdl-38711135

BACKGROUND: PSMA PET/CT is a predictive and prognostic biomarker for determining response to [177Lu]Lu-PSMA-617 in patients with metastatic castration resistant prostate cancer (mCRPC). Thresholds defined to date may not be generalizable to newer image reconstruction algorithms. Bayesian penalized likelihood (BPL) reconstruction algorithm is a novel reconstruction algorithm that may improve contrast whilst preventing introduction of image noise. The aim of this study is to compare the quantitative parameters obtained using BPL and the Ordered Subset Expectation Maximization (OSEM) reconstruction algorithms. METHODS: Fifty consecutive patients with mCRPC who underwent [68Ga]Ga-PSMA-11 PET/CT using OSEM reconstruction to assess suitability for [177Lu]Lu-PSMA-617 therapy were selected. BPL algorithm was then used retrospectively to reconstruct the same PET raw data. Quantitative and volumetric measurements such as tumour standardised uptake value (SUV)max, SUVmean and Molecular Tumour Volume (MTV-PSMA) were calculated on both reconstruction methods. Results were compared (Bland-Altman, Pearson correlation coefficient) including subgroups with low and high-volume disease burdens (MTV-PSMA cut-off 40 mL). RESULTS: The SUVmax and SUVmean were higher, and MTV-PSMA was lower in the BPL reconstructed images compared to the OSEM group, with a mean difference of 8.4 (17.5%), 0.7 (8.2%) and - 21.5 mL (-3.4%), respectively. There was a strong correlation between the calculated SUVmax, SUVmean, and MTV-PSMA values in the OSEM and BPL reconstructed images (Pearson r values of 0.98, 0.99, and 1.0, respectively). No patients were reclassified from low to high volume disease or vice versa when switching from OSEM to BPL reconstruction. CONCLUSIONS: [68Ga]Ga-PSMA-11 PET/CT quantitative and volumetric parameters produced by BPL and OSEM reconstruction methods are strongly correlated. Differences are proportional and small for SUVmean, which is used as a predictive biomarker. Our study suggests that both reconstruction methods are acceptable without clinical impact on quantitative or volumetric findings. For longitudinal comparison, committing to the same reconstruction method would be preferred to ensure consistency.


Algorithms , Bayes Theorem , Gallium Isotopes , Gallium Radioisotopes , Positron Emission Tomography Computed Tomography , Prostatic Neoplasms, Castration-Resistant , Humans , Male , Positron Emission Tomography Computed Tomography/methods , Prostatic Neoplasms, Castration-Resistant/diagnostic imaging , Prostatic Neoplasms, Castration-Resistant/pathology , Aged , Middle Aged , Retrospective Studies , Oligopeptides , Edetic Acid/analogs & derivatives , Whole Body Imaging/methods , Radiopharmaceuticals , Aged, 80 and over , Neoplasm Metastasis , Image Processing, Computer-Assisted/methods , Dipeptides/therapeutic use
2.
J Nucl Med ; 65(Suppl 1): 54S-63S, 2024 May 06.
Article En | MEDLINE | ID: mdl-38719233

In recent decades, researchers worldwide have directed their efforts toward enhancing the quality of PET imaging. The detection sensitivity and image resolution of conventional PET scanners with a short axial field of view have been constrained, leading to a suboptimal signal-to-noise ratio. The advent of long-axial-field-of-view PET scanners, exemplified by the uEXPLORER system, marked a significant advancement. Total-body PET imaging possesses an extensive scan range of 194 cm and an ultrahigh detection sensitivity, and it has emerged as a promising avenue for improving image quality while reducing the administered radioactivity dose and shortening acquisition times. In this review, we elucidate the application of the uEXPLORER system at the Sun Yat-sen University Cancer Center, including the disease distribution, patient selection workflow, scanning protocol, and several enhanced clinical applications, along with encountered challenges. We anticipate that this review will provide insights into routine clinical practice and ultimately improve patient care.


Positron Emission Tomography Computed Tomography , Whole Body Imaging , Humans , Positron Emission Tomography Computed Tomography/methods , Whole Body Imaging/methods , Neoplasms/diagnostic imaging , Tertiary Care Centers , Cancer Care Facilities , Image Processing, Computer-Assisted/methods
3.
J Nucl Med ; 65(Suppl 1): 46S-53S, 2024 May 06.
Article En | MEDLINE | ID: mdl-38719239

Total-body PET, an emerging technique, enables high-quality simultaneous total-body dynamic PET acquisition and accurate kinetic analysis. It has the potential to facilitate the study of multiple tracers while minimizing radiation dose and improving tracer-specific imaging. This advancement holds promise for enhancing the development and clinical evaluation of drugs, particularly radiopharmaceuticals. Multiple clinical trials are using a total-body PET scanner to explore existing and innovative radiopharmaceuticals. However, challenges persist, along with the opportunities, with regard to the use of total-body PET in drug development and evaluation. Specifically, considerations relate to the role of total-body PET in clinical pharmacologic evaluations and its integration into the theranostic paradigm. In this review, state-of-the-art total-body PET and its potential roles in pharmaceutical research are explored.


Drug Development , Positron-Emission Tomography , Whole Body Imaging , Humans , Positron-Emission Tomography/methods , Radiopharmaceuticals , Animals
4.
J Nucl Med ; 65(Suppl 1): 64S-71S, 2024 May 06.
Article En | MEDLINE | ID: mdl-38719242

Total-body (TB) PET/CT is a groundbreaking tool that has brought about a revolution in both clinical application and scientific research. The transformative impact of TB PET/CT in the realms of clinical practice and scientific exploration has been steadily unfolding since its introduction in 2018, with implications for its implementation within the health care landscape of China. TB PET/CT's exceptional sensitivity enables the acquisition of high-quality images in significantly reduced time frames. Clinical applications have underscored its effectiveness across various scenarios, emphasizing the capacity to personalize dosage, scan duration, and image quality to optimize patient outcomes. TB PET/CT's ability to perform dynamic scans with high temporal and spatial resolution and to perform parametric imaging facilitates the exploration of radiotracer biodistribution and kinetic parameters throughout the body. The comprehensive TB coverage offers opportunities to study interconnections among organs, enhancing our understanding of human physiology and pathology. These insights have the potential to benefit applications requiring holistic TB assessments. The standard topics outlined in The Journal of Nuclear Medicine were used to categorized the reviewed articles into 3 sections: current clinical applications, scan protocol design, and advanced topics. This article delves into the bottleneck that impedes the full use of TB PET in China, accompanied by suggested solutions.


Whole Body Imaging , Humans , China , Positron Emission Tomography Computed Tomography , Positron-Emission Tomography/methods
5.
Rev Soc Bras Med Trop ; 57: e004062024, 2024.
Article En | MEDLINE | ID: mdl-38808799

BACKGROUND: Musculoskeletal inflammatory lesions in chronic Chikungunya virus (CHIKV) infection have not been thoroughly assessed using whole-body magnetic resonance imaging (WBMRI). This study aimed to determine the prevalence of these lesions in such patients. METHODS: From September 2018 to February 2019, patients with positive Chikungunya-specific serology (Immunoglobulin M/Immunoglobulin G anti-CHIKV), with a history of polyarthralgia for > 6 months prior to MRI with no pre-existing rheumatic disorders, underwent 3T WBMRI and localized MRI. The evaluation focused on musculoskeletal inflammatory lesions correlated with chronic CHIKV infection. Pain levels were assessed using a visual analogue scale on the same day as WBMRI. RESULTS: The study included 86 patients of whom 26 met the inclusion criteria. All patients reported pain and most (92.3%) categorized it as moderate or severe. The most common finding across joints was effusion, particularly in the tibiotalar joint (57.7%) and bursitis, with the retrocalcaneal bursa most affected (48.0%). Tenosynovitis was prevalent in the flexor compartment of the hands (44.2%), while Kager fat pad and soleus edema were also observed. Bone marrow edema-like signals were frequently seen in the sacroiliac joints (19.2%). Most WBMRI findings were classified as mild. CONCLUSIONS: This study represents the first utilization of 3T WBMRI to assess musculoskeletal inflammatory disorders in chronic CHIKV infection. The aim was to identify the most affected joints and prevalent lesions, providing valuable insights for future research and clinical management of this condition regarding understanding disease pathophysiology, developing targeted treatment strategies, and using advanced imaging techniques in the assessment of musculoskeletal manifestations.


Chikungunya Fever , Magnetic Resonance Imaging , Whole Body Imaging , Humans , Chikungunya Fever/complications , Chikungunya Fever/diagnostic imaging , Male , Female , Middle Aged , Adult , Chronic Disease , Aged , Musculoskeletal Diseases/diagnostic imaging , Young Adult
6.
Sci Data ; 11(1): 483, 2024 May 10.
Article En | MEDLINE | ID: mdl-38729970

The Sparsely Annotated Region and Organ Segmentation (SAROS) dataset was created using data from The Cancer Imaging Archive (TCIA) to provide a large open-access CT dataset with high-quality annotations of body landmarks. In-house segmentation models were employed to generate annotation proposals on randomly selected cases from TCIA. The dataset includes 13 semantic body region labels (abdominal/thoracic cavity, bones, brain, breast implant, mediastinum, muscle, parotid/submandibular/thyroid glands, pericardium, spinal cord, subcutaneous tissue) and six body part labels (left/right arm/leg, head, torso). Case selection was based on the DICOM series description, gender, and imaging protocol, resulting in 882 patients (438 female) for a total of 900 CTs. Manual review and correction of proposals were conducted in a continuous quality control cycle. Only every fifth axial slice was annotated, yielding 20150 annotated slices from 28 data collections. For the reproducibility on downstream tasks, five cross-validation folds and a test set were pre-defined. The SAROS dataset serves as an open-access resource for training and evaluating novel segmentation models, covering various scanner vendors and diseases.


Tomography, X-Ray Computed , Whole Body Imaging , Female , Humans , Male , Image Processing, Computer-Assisted
7.
Science ; 384(6696): eadm7168, 2024 May 10.
Article En | MEDLINE | ID: mdl-38723062

Despite a half-century of advancements, global magnetic resonance imaging (MRI) accessibility remains limited and uneven, hindering its full potential in health care. Initially, MRI development focused on low fields around 0.05 Tesla, but progress halted after the introduction of the 1.5 Tesla whole-body superconducting scanner in 1983. Using a permanent 0.05 Tesla magnet and deep learning for electromagnetic interference elimination, we developed a whole-body scanner that operates using a standard wall power outlet and without radiofrequency and magnetic shielding. We demonstrated its wide-ranging applicability for imaging various anatomical structures. Furthermore, we developed three-dimensional deep learning reconstruction to boost image quality by harnessing extensive high-field MRI data. These advances pave the way for affordable deep learning-powered ultra-low-field MRI scanners, addressing unmet clinical needs in diverse health care settings worldwide.


Deep Learning , Magnetic Resonance Imaging , Whole Body Imaging , Magnetic Resonance Imaging/methods , Whole Body Imaging/methods , Humans , Imaging, Three-Dimensional/methods
8.
Muscle Nerve ; 70(1): 101-110, 2024 Jul.
Article En | MEDLINE | ID: mdl-38698725

INTRODUCTION/AIMS: Whole-body magnetic resonance neurography (MRN) is an imaging modality that shows peripheral nerve signal change in patients with chronic inflammatory demyelinating polyneuropathy (CIDP). We aimed to explore the diagnostic potential of whole-body MRN and its potential as a monitoring tool after immunotherapy in treatment-naïve CIDP patients. METHODS: Whole-body MRN using coronal 3-dimensional short tau inversion recovery (STIR) sampling perfection with application-optimized contrasts by using different flip angle evolution (SPACE) techniques was performed in patients being investigated for CIDP and in healthy controls. Baseline clinical neuropathy scales and electrophysiologic parameters were collected, and MRN findings were compared before and after CIDP treatment. RESULTS: We found highly concordant symmetrical thickening and increased T2 signal intensities in the brachial/lumbosacral plexus, femoral, or sciatic nerves in five of the eight patients with a final diagnosis of CIDP and none of the healthy controls. There were no treatment-related imaging changes in five patients with CIDP who completed a follow-up study. Diffuse, symmetrical thickening, and increased T2 signal in root, plexus, and peripheral nerves were found in two patients ultimately excluded due to a diagnosis of polyneuropathy, organomegaly, endocrinopathy, monoclonal gammopathy, skin changes (POEMS) syndrome in addition to signal changes in the muscles, bony lesions, organomegaly, and lymphadenopathy. DISCUSSION: Whole-body MRN imaging shows promise in detecting abnormalities in proximal nerve segments in patients with CIDP. Future studies evaluating the role of MRN in assessing treatment response should consider follow-up scans after treatment durations of more than 4 months.


Magnetic Resonance Imaging , Polyradiculoneuropathy, Chronic Inflammatory Demyelinating , Whole Body Imaging , Humans , Polyradiculoneuropathy, Chronic Inflammatory Demyelinating/diagnostic imaging , Polyradiculoneuropathy, Chronic Inflammatory Demyelinating/physiopathology , Male , Female , Middle Aged , Magnetic Resonance Imaging/methods , Aged , Whole Body Imaging/methods , Adult , Peripheral Nerves/diagnostic imaging , Neural Conduction/physiology
10.
Clin Nucl Med ; 49(5): 451-453, 2024 May 01.
Article En | MEDLINE | ID: mdl-38557553

ABSTRACT: 131 I has been used effectively over the years in both diagnosis and therapy of differentiated thyroid cancer (DTC). Although whole-body scan with 131 I is a highly sensitive tool for detecting normal thyroid tissue and metastasis of DTC, it is not specific; therefore, false-positive images can be seen in clinical practice, and their recognition is critical for correct management. Evaluation of false-positive uptake is important because it may be confused with metastatic involvement. Here, we present a rare false-positive result of whole-body scan in a patient with DTC. To our knowledge, it is the first report on 131 I uptake of conjunctival concretions.


Adenocarcinoma , Thyroid Neoplasms , Humans , Whole Body Imaging , Radionuclide Imaging , Thyroid Neoplasms/pathology , Thyroidectomy , Adenocarcinoma/drug therapy , Iodine Radioisotopes/therapeutic use
11.
Clin Nucl Med ; 49(6): e301-e303, 2024 Jun 01.
Article En | MEDLINE | ID: mdl-38598541

ABSTRACT: Differentiated thyroid carcinoma constitutes over 90% of all thyroid cancers. The standard treatment approach involves total or near-total thyroidectomy with or without neck dissection followed by 131 I whole-body scintigraphy (WBS) to detect local or distant metastases. Radioiodine offers high sensitivity and specificity for detection of metastatic disease in well differentiated thyroid carcinoma. However, despite its high accuracy, 131 I WBS demonstrates false-positive results, mostly at inflammatory or infective site. These false-positive radioiodine accumulation can lead to misdiagnosis and unwarranted radioiodine treatment. This case presents localization of 131 I to the suture site granuloma leading to false-positive results on 131 I WBS.


Iodine Radioisotopes , Lymphatic Metastasis , Radionuclide Imaging , Whole Body Imaging , Humans , Diagnosis, Differential , Lymphatic Metastasis/diagnostic imaging , Sutures/adverse effects , Granuloma/diagnostic imaging , Female , Neck/diagnostic imaging , Thyroid Neoplasms/diagnostic imaging , Middle Aged , Male , Biological Transport
12.
Neuroimage ; 293: 120611, 2024 Jun.
Article En | MEDLINE | ID: mdl-38643890

Dynamic PET allows quantification of physiological parameters through tracer kinetic modeling. For dynamic imaging of brain or head and neck cancer on conventional PET scanners with a short axial field of view, the image-derived input function (ID-IF) from intracranial blood vessels such as the carotid artery (CA) suffers from severe partial volume effects. Alternatively, optimization-derived input function (OD-IF) by the simultaneous estimation (SIME) method does not rely on an ID-IF but derives the input function directly from the data. However, the optimization problem is often highly ill-posed. We proposed a new method that combines the ideas of OD-IF and ID-IF together through a kernel framework. While evaluation of such a method is challenging in human subjects, we used the uEXPLORER total-body PET system that covers major blood pools to provide a reference for validation. METHODS: The conventional SIME approach estimates an input function using a joint estimation together with kinetic parameters by fitting time activity curves from multiple regions of interests (ROIs). The input function is commonly parameterized with a highly nonlinear model which is difficult to estimate. The proposed kernel SIME method exploits the CA ID-IF as a priori information via a kernel representation to stabilize the SIME approach. The unknown parameters are linear and thus easier to estimate. The proposed method was evaluated using 18F-fluorodeoxyglucose studies with both computer simulations and 20 human-subject scans acquired on the uEXPLORER scanner. The effect of the number of ROIs on kernel SIME was also explored. RESULTS: The estimated OD-IF by kernel SIME showed a good match with the reference input function and provided more accurate estimation of kinetic parameters for both simulation and human-subject data. The kernel SIME led to the highest correlation coefficient (R = 0.97) and the lowest mean absolute error (MAE = 10.5 %) compared to using the CA ID-IF (R = 0.86, MAE = 108.2 %) and conventional SIME (R = 0.57, MAE = 78.7 %) in the human-subject evaluation. Adding more ROIs improved the overall performance of the kernel SIME method. CONCLUSION: The proposed kernel SIME method shows promise to provide an accurate estimation of the blood input function and kinetic parameters for brain PET parametric imaging.


Brain , Positron-Emission Tomography , Humans , Positron-Emission Tomography/methods , Positron-Emission Tomography/standards , Brain/diagnostic imaging , Whole Body Imaging/methods , Image Processing, Computer-Assisted/methods , Algorithms
13.
Semin Arthritis Rheum ; 66: 152437, 2024 Jun.
Article En | MEDLINE | ID: mdl-38564998

Inter-reader reliability of a new scoring system for evaluating joint inflammation and enthesitis in whole body MRI (WBMRI) in juvenile idiopathic arthritis was tested. The scoring system grades 732 item-region combinations of bone marrow and soft tissue changes for commonly involved joints and entheseal sites. Five radiologists rated 17 WBMRI scans through an online rating platform. Item-wise reliability was calculated for 117 items with non-zero scores in >10 % of readings. Interquartile ranges of the five-reader Kappa reliability coefficients were 0.58-0.73 (range: 0.36-0.88) for the joints, 0.65-0.81 (range: 0.39-0.95) for the entheses, and 0.62-0.75 (range: 0.60-0.76) for chronic nonbacterial osteomyelitis-like lesions.


Arthritis, Juvenile , Magnetic Resonance Imaging , Whole Body Imaging , Humans , Arthritis, Juvenile/diagnostic imaging , Magnetic Resonance Imaging/methods , Reproducibility of Results , Child , Whole Body Imaging/methods , Male , Severity of Illness Index , Female , Adolescent , Joints/diagnostic imaging , Child, Preschool
14.
J Nucl Med ; 65(6): 856-863, 2024 Jun 03.
Article En | MEDLINE | ID: mdl-38604764

68Ga-labeled nanobody (68Ga-NC-BCH) is a single-domain antibody-based PET imaging agent. We conducted a first-in-humans study of 68Ga-NC-BCH for PET to determine its in vivo biodistribution, metabolism, radiation dosimetry, safety, and potential for quantifying claudin-18 isoform 2 (CLDN18.2) expression in gastrointestinal cancer patients. Methods: Initially, we synthesized the probe 68Ga-NC-BCH and performed preclinical evaluations on human gastric adenocarcinoma cell lines and xenograft mouse models. Next, we performed a translational study with a pilot cohort of patients with advanced gastrointestinal cancer on a total-body PET/CT scanner. Radiopharmaceutical biodistribution, radiation dosimetry, and the relationship between tumor uptake and CLDN18.2 expression were evaluated. Results: 68Ga-NC-BCH was stably prepared and demonstrated good radiochemical properties. According to preclinical evaluation,68Ga-NC-BCH exhibited rapid blood clearance, high affinity for CLDN18.2, and high specific uptake in CLDN18.2-positive cells and xenograft mouse models. 68Ga-NC-BCH displayed high uptake in the stomach and kidney and slight uptake in the pancreas. Compared with 18F-FDG, 68Ga-NC-BCH showed significant differences in uptake in lesions with different levels of CLDN18.2 expression. Conclusion: A clear correlation was detected between PET SUV and CLDN18.2 expression, suggesting that 68Ga-NC-BCH PET could be used as a companion diagnostic tool for optimizing treatments that target CLDN18.2 in tumors.


Claudins , Gallium Radioisotopes , Gastrointestinal Neoplasms , Whole Body Imaging , Humans , Animals , Mice , Cell Line, Tumor , Claudins/metabolism , Female , Gastrointestinal Neoplasms/diagnostic imaging , Gastrointestinal Neoplasms/metabolism , Male , Tissue Distribution , Middle Aged , Positron-Emission Tomography/methods , Positron Emission Tomography Computed Tomography/methods , Aged , Radiopharmaceuticals/pharmacokinetics
15.
Clin Nucl Med ; 49(7): e327-e328, 2024 Jul 01.
Article En | MEDLINE | ID: mdl-38687008

ABSTRACT: In a recent 99m Tc-HYNIC-PSMA study conducted at our department, we examined 2 patients with prostate cancer referred for initial staging on the same day. The whole-body scans revealed radiotracer uptake in the gastric mucosa and thyroid glands, alluding to high levels of free TcO 4- in the injected vial. The scans were repeated after confirming acceptable radiopharmaceutical purity of 97% (normal range, 95%-100%). Interestingly, 1 patient had liver metastases at presentation, which remained non-PSMA-avid after repeating the scan. We have reviewed this pitfall, which has been reported with many radiotracers, yet not reported with PSMA tracers.


Organotechnetium Compounds , Prostatic Neoplasms , Humans , Male , Prostatic Neoplasms/diagnostic imaging , Aged , Glutamate Carboxypeptidase II/metabolism , Whole Body Imaging , Middle Aged , Antigens, Surface
16.
Hum Brain Mapp ; 45(5): e26654, 2024 Apr.
Article En | MEDLINE | ID: mdl-38520361

Obesity represents a significant public health concern and is linked to various comorbidities and cognitive impairments. Previous research indicates that elevated body mass index (BMI) is associated with structural changes in white matter (WM). However, a deeper characterization of body composition is required, especially considering the links between abdominal obesity and metabolic dysfunction. This study aims to enhance our understanding of the relationship between obesity and WM connectivity by directly assessing the amount and distribution of fat tissue. Whole-body magnetic resonance imaging (MRI) was employed to evaluate total adipose tissue (TAT), visceral adipose tissue (VAT), and subcutaneous adipose tissue (SAT), while MR liver spectroscopy measured liver fat content in 63 normal-weight, overweight, and obese males. WM connectivity was quantified using microstructure-informed tractography. Connectome-based predictive modeling was used to predict body composition metrics based on WM connectomes. Our analysis revealed a positive dependency between BMI, TAT, SAT, and WM connectivity in brain regions involved in reward processing and appetite regulation, such as the insula, nucleus accumbens, and orbitofrontal cortex. Increased connectivity was also observed in cognitive control and inhibition networks, including the middle frontal gyrus and anterior cingulate cortex. No significant associations were found between WM connectivity and VAT or liver fat. Our findings suggest that altered neural communication between these brain regions may affect cognitive processes, emotional regulation, and reward perception in individuals with obesity, potentially contributing to weight gain. While our study did not identify a link between WM connectivity and VAT or liver fat, further investigation of the role of various fat depots and metabolic factors in brain networks is required to advance obesity prevention and treatment approaches.


Magnetic Resonance Imaging , White Matter , Male , Humans , White Matter/pathology , Tissue Distribution , Whole Body Imaging , Obesity/diagnostic imaging , Obesity/complications , Adipose Tissue/diagnostic imaging , Adipose Tissue/metabolism , Adipose Tissue/pathology
17.
J Nucl Med ; 65(5): 714-721, 2024 May 01.
Article En | MEDLINE | ID: mdl-38548347

The lungs are supplied by both the pulmonary arteries carrying deoxygenated blood originating from the right ventricle and the bronchial arteries carrying oxygenated blood downstream from the left ventricle. However, this effect of dual blood supply has never been investigated using PET, partially because the temporal resolution of conventional dynamic PET scans is limited. The advent of PET scanners with a long axial field of view, such as the uEXPLORER total-body PET/CT system, permits dynamic imaging with high temporal resolution (HTR). In this work, we modeled the dual-blood input function (DBIF) and studied its impact on the kinetic quantification of normal lung tissue and lung tumors using HTR dynamic PET imaging. Methods: Thirteen healthy subjects and 6 cancer subjects with lung tumors underwent a dynamic 18F-FDG scan with the uEXPLORER for 1 h. Data were reconstructed into dynamic frames of 1 s in the early phase. Regional time-activity curves of lung tissue and tumors were analyzed using a 2-tissue compartmental model with 3 different input functions: the right ventricle input function, left ventricle input function, and proposed DBIF, all with time delay and dispersion corrections. These models were compared for time-activity curve fitting quality using the corrected Akaike information criterion and for differentiating lung tumors from lung tissue using the Mann-Whitney U test. Voxelwise multiparametric images by the DBIF model were further generated to verify the regional kinetic analysis. Results: The effect of dual blood supply was pronounced in the high-temporal-resolution time-activity curves of lung tumors. The DBIF model achieved better time-activity curve fitting than the other 2 single-input models according to the corrected Akaike information criterion. The estimated fraction of left ventricle input was low in normal lung tissue of healthy subjects but much higher in lung tumors (∼0.04 vs. ∼0.3, P < 0.0003). The DBIF model also showed better robustness in the difference in 18F-FDG net influx rate [Formula: see text] and delivery rate [Formula: see text] between lung tumors and normal lung tissue. Multiparametric imaging with the DBIF model further confirmed the differences in tracer kinetics between normal lung tissue and lung tumors. Conclusion: The effect of dual blood supply in the lungs was demonstrated using HTR dynamic imaging and compartmental modeling with the proposed DBIF model. The effect was small in lung tissue but nonnegligible in lung tumors. HTR dynamic imaging with total-body PET can offer a sensitive tool for investigating lung diseases.


Lung Neoplasms , Positron-Emission Tomography , Humans , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/metabolism , Male , Female , Middle Aged , Kinetics , Positron-Emission Tomography/methods , Models, Biological , Adult , Fluorodeoxyglucose F18 , Aged , Whole Body Imaging , Positron Emission Tomography Computed Tomography , Image Processing, Computer-Assisted , Time Factors , Radiopharmaceuticals/pharmacokinetics
18.
J Neurol ; 271(6): 3186-3202, 2024 Jun.
Article En | MEDLINE | ID: mdl-38438820

OBJECTIVE: Inflammatory myopathies (IIM) include dermatomyositis (DM), sporadic inclusion body myositis (sIBM), immune-mediated necrotizing myopathy (IMNM), and overlap myositis (OLM)/antisynthetase syndrome (ASyS). There is also a rare variant termed polymyositis with mitochondrial pathology (PM-Mito), which is considered a sIBM precursor. There is no information regarding muscle MRI for this rare entity. The aim of this study was to compare MRI findings in IIM, including PM-Mito. METHODS: This retrospective analysis included 41 patients (7 PM-Mito, 11 sIBM, 11 PM/ASyS/OLM, 12 IMNM) and 20 healthy controls. Pattern of muscle involvement was assessed by semiquantitative evaluation, while Dixon method was used to quantify muscular fat fraction. RESULTS: The sIBM typical pattern affecting the lower extremities was not found in the majority of PM-Mito-patients. Intramuscular edema in sIBM and PM-Mito was limited to the lower extremities, whereas IMNM and PM/ASyS/OLM showed additional edema in the trunk. Quantitative assessment showed increased fat content in sIBM, with an intramuscular proximo-distal gradient. Similar changes were also found in a few PM-Mito- and PM/ASyS/OLM patients. In sIBM and PM-Mito, mean fat fraction of several muscles correlated with clinical involvement. INTERPRETATION: As MRI findings in patients with PM-Mito relevantly differed from sIBM, the attribution of PM-Mito as sIBM precursor should be critically discussed. Some patients in PM/ASyS/OLM and PM-Mito group showed MR-morphologic features predominantly observed in sIBM, indicative of a spectrum from PM/ASyS/OLM toward sIBM. In some IIM subtypes, MRI may serve as a biomarker of disease severity.


Magnetic Resonance Imaging , Muscle, Skeletal , Myositis , Polymyositis , Humans , Male , Female , Middle Aged , Retrospective Studies , Myositis/diagnostic imaging , Myositis/pathology , Polymyositis/diagnostic imaging , Polymyositis/pathology , Muscle, Skeletal/diagnostic imaging , Muscle, Skeletal/pathology , Adult , Aged , Whole Body Imaging/methods
19.
Injury ; 55(5): 111494, 2024 May.
Article En | MEDLINE | ID: mdl-38521635

BACKGROUND: Whole-Body CT (WBCT) is frequently used in emergency situations for promptly diagnosing paediatric polytrauma patients, given the challenges associated with obtaining precise details about the mechanism and progression of trauma. However, WBCT does not lead to reduced mortality in paediatric patients, but is associated with high radiation exposure. We therefore wanted to develop a screening tool for CT demand-driven emergency room (ER)-trauma diagnostic to reduce radiation exposure in paediatric patients. METHODS: A retrospective study in a Level I trauma centre in Germany was performed. Data from 344 paediatric emergency patients with critical mechanism of injury who were pre-announced by the ambulance for the trauma room were collected. Patients' symptoms, clinical examination, extended Focused Assessment with Sonography for Trauma (eFAST), routinely, laboratory tests and blood gas and - when obtained - WBCT images were analysed. To identify potential predictors of severe injuries (ISS > 23), 300 of the 344 cases with complete data were subjected to regression analyses model. RESULTS: Multiple regression analysis identified cGCS, base excess (BE), medically abnormal results from eFAST screening, initial unconsciousness, and injuries involving three or more body regions as significant predictors for a screening tool for decision-making to perform WBCT or selective CT. The developed Paediatric polytrauma CT-Indication (PePCI)-Score was divided into three risk categories and achieved a sensitivity of 87 % and a specificity of 71 % when comparing the low and medium risk groups with the high risk group. Comparing only the low-risk group with the high-risk group for the decision to perform WBCT, 32/35 (91 %) of patients with an ISS >23 were correctly identified, as were 124/137 (91 %) with lower ISS scores. CONCLUSION: With the newly developed PePCI-Score, the frequency of WBCT in a paediatric emergency patients collective can be significantly reduced according to our data. After prospective validation, the initial assessment of paediatric trauma patients in the future could be made not only by the mechanism of injury, but also by the new PePCI-Score, deriving on clinical findings after thorough clinical assessment and the discretion of the trauma team.


Multiple Trauma , Whole Body Imaging , Humans , Child , Retrospective Studies , Prognosis , Whole Body Imaging/methods , Tomography, X-Ray Computed/methods , Injury Severity Score
20.
Int J Gynecol Cancer ; 34(6): 871-878, 2024 Jun 03.
Article En | MEDLINE | ID: mdl-38531539

BACKGROUND: In addition to the diagnostic accuracy of imaging methods, patient-reported satisfaction with imaging methods is important. OBJECTIVE: To report a secondary outcome of the prospective international multicenter Imaging Study in Advanced ovArian Cancer (ISAAC Study), detailing patients' experience with abdomino-pelvic ultrasound, whole-body contrast-enhanced computed tomography (CT), and whole-body diffusion-weighted magnetic resonance imaging (WB-DWI/MRI) for pre-operative ovarian cancer work-up. METHODS: In total, 144 patients with suspected ovarian cancer at four institutions in two countries (Italy, Czech Republic) underwent ultrasound, CT, and WB-DWI/MRI for pre-operative work-up between January 2020 and November 2022. After having undergone all three examinations, the patients filled in a questionnaire evaluating their overall experience and experience in five domains: preparation before the examination, duration of examination, noise during the procedure, radiation load of CT, and surrounding space. Pain perception, examination-related patient-perceived unexpected, unpleasant, or dangerous events ('adverse events'), and preferred method were also noted. RESULTS: Ultrasound was the preferred method by 49% (70/144) of responders, followed by CT (38%, 55/144), and WB-DWI/MRI (13%, 19/144) (p<0.001). The poorest experience in all domains was reported for WB-DWI/MRI, which was also associated with the largest number of patients who reported adverse events (eg, dyspnea). Patients reported higher levels of pain during the ultrasound examination than during CT and WB-DWI/MRI (p<0.001): 78% (112/144) reported no pain or mild pain, 19% (27/144) moderate pain, and 3% (5/144) reported severe pain (pain score >7 of 10) during the ultrasound examination. We did not identify any factors related to patients' preferred method. CONCLUSION: Ultrasound was the imaging method preferred by most patients despite being associated with more pain during the examination in comparison with CT and WB-DWI/MRI. TRIAL REGISTRATION NUMBER: NCT03808792.


Diffusion Magnetic Resonance Imaging , Ovarian Neoplasms , Patient Satisfaction , Tomography, X-Ray Computed , Ultrasonography , Humans , Female , Ovarian Neoplasms/diagnostic imaging , Ovarian Neoplasms/pathology , Prospective Studies , Middle Aged , Diffusion Magnetic Resonance Imaging/methods , Cross-Sectional Studies , Ultrasonography/methods , Aged , Tomography, X-Ray Computed/methods , Adult , Neoplasm Staging , Whole Body Imaging/methods , Aged, 80 and over , Preoperative Care/methods
...