Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Acta Orthop Traumatol Turc ; 50(4): 415-23, 2016 Aug.
Article in English | MEDLINE | ID: mdl-27524671

ABSTRACT

OBJECTIVE: In our study, we aimed to evaluate the influence of training on compliance and persistence with bisphosphonate treatment given on a weekly vs. monthly basis in postmenopausal osteoporosis patients. METHODS: A total of 979 patients with postmenopausal osteoporosis (mean age: 63.2 ± 7.2 years) were included in this national, multicenter, prospective non-interventional observational cohort registry study. Patients were randomized into training (n = 492, 50.3%, mean age: 63.4 ± 7.2 years) and control (n = 487, 49.7%, mean age: 63.0 ± 7.1 years) groups. Patients in each intervention group were given weekly (44.9% and 44.6% for training and control subjects, respectively) or monthly (55.1% and 55.4%, respectively) bisphosphonate regimens. After the initial visit, patients were followed up at three-month intervals throughout 12 months of treatment for evaluation of persistence, compliance and adverse events. RESULTS: On average, 79.4% of the patients were persistent with the treatment with a mean of 350.4 days of duration during the 12-month follow-up period. The mean compliance in the compliant and fully compliant group remained at an average of 86.6%. No significant difference was detected between the training and control groups in terms of compliance and persistence. Significantly longer persistence (360.0 ± 89.0 vs. 345.0 ± 108.0 days; p = 0.035), higher percentage of persistent patients (83.4% vs. 74.2%; p = 0.012) and higher compliance rates (88.8% vs. 83.3%; p = 0.002) were noted in monthly regimen patients in comparison to those given weekly regimen. CONCLUSION: Our findings revealed remarkably high rates for persistence and compliance with bisphosphonate treatment in postmenopausal osteoporosis, with no impact of training on compliance and persistence rates. Longer persistence and better compliance rates were achieved with the monthly bisphosphonate regimen when compared to the weekly regimen.


Subject(s)
Bone Density Conservation Agents/administration & dosage , Diphosphonates/administration & dosage , Medication Adherence/statistics & numerical data , Osteoporosis, Postmenopausal/drug therapy , Patient Education as Topic/methods , Aged , Drug Administration Schedule , Female , Humans , Middle Aged , Prospective Studies , Turkey
2.
Clinics (Sao Paulo) ; 65(6): 613-9, 2010 Jun.
Article in English | MEDLINE | ID: mdl-20613938

ABSTRACT

INTRODUCTION: Cerebral palsy is the most common cause of physical disability in children. Spasticity is a disabling clinical symptom that is prevalent among patients suffering from cerebral palsy. The treatment of spasticity with botulinum toxin type A (BTX-A) is a well-established option in the interdisciplinary management of spasticity, providing focal reductions in muscle tone in cerebral palsy patients. OBJECTIVE: The aim of this retrospective study was to describe the effect of multilevel BTX-A injections in the lower extremities, focusing mainly on gross motor function and functional status in cerebral palsy patients. METHODS: Data from 71 cerebral palsy patients (64% male, 36% female, mean age 6.7 +/-3.2 years) were analyzed retrospectively. We used the Ashworth and Tardieu scales to evaluate the degree of spasticity. Motor function was measured by the Gross Motor Function Measure (GMFM-88), and functional status was classified by the Gross Motor Function Classification System (GMFCS I-V). Multilevel BTX-A injections were applied after sedation and with electrostimulation guidance. The evaluations were repeated every three months, and the patients were followed for six months. RESULTS: We found that the Ashworth and Tardieu scores decreased significantly at the three-month evaluation (p<0.05) but not at the six-month evaluation (p>0.05). Although the improvement in spasticity was not maintained at the six-month evaluation, GMFM-88 scores increased significantly at the three- and six-month assessments. GMFSC levels showed no change in the three- and six-month assessments. CONCLUSION: We believe that a single multilevel BTX-A injection reduces spasticity and improves motor function in children with cerebral palsy.


Subject(s)
Botulinum Toxins, Type A/administration & dosage , Cerebral Palsy/complications , Neuromuscular Agents/administration & dosage , Child , Child, Preschool , Female , Humans , Infant , Injections, Intramuscular , Male , Motor Skills/physiology , Muscle Spasticity/drug therapy , Retrospective Studies
3.
Clinics ; 65(6): 613-619, 2010. tab, ilus
Article in English | LILACS | ID: lil-553967

ABSTRACT

INTRODUCTION: Cerebral palsy is the most common cause of physical disability in children. Spasticity is a disabling clinical symptom that is prevalent among patients suffering from cerebral palsy. The treatment of spasticity with botulinum toxin type A (BTX-A) is a well-established option in the interdisciplinary management of spasticity, providing focal reductions in muscle tone in cerebral palsy patients. OBJECTIVE: The aim of this retrospective study was to describe the effect of multilevel BTX-A injections in the lower extremities, focusing mainly on gross motor function and functional status in cerebral palsy patients. METHODS: Data from 71 cerebral palsy patients (64 percent male, 36 percent female, mean age 6.7 ±3.2 years) were analyzed retrospectively. We used the Ashworth and Tardieu scales to evaluate the degree of spasticity. Motor function was measured by the Gross Motor Function Measure (GMFM-88), and functional status was classified by the Gross Motor Function Classification System (GMFCS I-V). Multilevel BTX-A injections were applied after sedation and with electrostimulation guidance. The evaluations were repeated every three months, and the patients were followed for six months. RESULTS: We found that the Ashworth and Tardieu scores decreased significantly at the three-month evaluation (p<0.05) but not at the six-month evaluation (p>0.05). Although the improvement in spasticity was not maintained at the six-month evaluation, GMFM-88 scores increased significantly at the three- and six-month assessments. GMFSC levels showed no change in the three- and six-month assessments. CONCLUSION: We believe that a single multilevel BTX-A injection reduces spasticity and improves motor function in children with cerebral palsy.


Subject(s)
Child , Child, Preschool , Female , Humans , Infant , Male , Botulinum Toxins, Type A/administration & dosage , Cerebral Palsy/complications , Neuromuscular Agents/administration & dosage , Injections, Intramuscular , Motor Skills/physiology , Muscle Spasticity/drug therapy , Retrospective Studies
4.
Clinics (Sao Paulo) ; 64(8): 757-62, 2009.
Article in English | MEDLINE | ID: mdl-19690659

ABSTRACT

OBJECTIVE: To evaluate how bone mineral density in the calcaneus measured by a dual energy X-ray laser (DXL) correlates with bone mineral density in the spine and hip in Turkish women over 40 years of age and to determine whether calcaneal dual energy X-ray laser variables are associated with clinical risk factors to the same extent as axial bone mineral density measurements obtained using dual energy x-ray absorbtiometry (DXA). MATERIALS AND METHODS: A total of 2,884 Turkish women, aged 40-90 years, living in Ankara were randomly selected. Calcaneal bone mineral density was evaluated using a dual energy X-ray laser Calscan device. Subjects exhibiting a calcaneal dual energy X-ray laser T- score < or = -2.5 received a referral for DXA of the spine and hip. Besides dual energy X-ray laser measurements, all subjects were questioned about their medical history and the most relevant risk factors for osteoporosis. RESULTS: Using a T-score threshold of -2.5, which is recommended by the World Health Organization (WHO), dual energy X-ray laser calcaneal measurements showed that 13% of the subjects had osteoporosis, while another 56% had osteopenia. The mean calcaneal dual energy X-ray laser T-score of postmenopausal subjects who were smokers with a positive history of fracture, hormone replacement therapy (HRT), covered dressing style, lower educational level, no regular exercise habits, and low tea consumption was significantly lower than that obtained for the other group (p<0.05). A significant correlation was observed between the calcaneal dual energy X-ray laser T-score and age (r= -0.465, p=0.001), body mass index (BMI) (r=0.223, p=0.001), number of live births (r= -0.229, p=0.001), breast feeding time (r= -0.064, p=0.001), and age at menarche (r= -0.050, p=0.008). The correlations between calcaneal DXL and DXA T-scores (r=0.340, p=0.001) and calcaneal DXL and DXA Z-scores (r=0.360, p=0.001) at the spine, and calcaneal DXL and DXA T- scores (r=0.28, p=0.001) and calcaneal DXL and DXA Z-scores (r=0.33, p=0.001) at the femoral neck were statistically significant. CONCLUSION: Bone mineral density measurements in the calcaneus using a dual energy X-ray laser are valuable for screening Turkish women over 40 years of age for the risk of osteoporosis.


Subject(s)
Absorptiometry, Photon/methods , Bone Density/physiology , Calcaneus/diagnostic imaging , Lasers , Osteoporosis/diagnostic imaging , Adult , Aged , Aged, 80 and over , Body Mass Index , Calcaneus/physiology , Female , Hip/diagnostic imaging , Hip/physiology , Humans , Mass Screening , Middle Aged , Risk Factors , Spine/diagnostic imaging , Spine/physiology , Turkey
5.
Clinics ; 64(8): 757-762, 2009. tab
Article in English | LILACS | ID: lil-523994

ABSTRACT

OBJECTIVE: To evaluate how bone mineral density in the calcaneus measured by a dual energy X-ray laser (DXL) correlates with bone mineral density in the spine and hip in Turkish women over 40 years of age and to determine whether calcaneal dual energy X-ray laser variables are associated with clinical risk factors to the same extent as axial bone mineral density measurements obtained using dual energy x-ray absorbtiometry (DXA). MATERIALS AND METHODS: A total of 2,884 Turkish women, aged 40-90 years, living in Ankara were randomly selected. Calcaneal bone mineral density was evaluated using a dual energy X-ray laser Calscan device. Subjects exhibiting a calcaneal dual energy X-ray laser T- score <-2.5 received a referral for DXA of the spine and hip. Besides dual energy X-ray laser measurements, all subjects were questioned about their medical history and the most relevant risk factors for osteoporosis. RESULTS: Using a T-score threshold of -2.5, which is recommended by the World Health Organization (WHO), dual energy X-ray laser calcaneal measurements showed that 13 percent of the subjects had osteoporosis, while another 56 percent had osteopenia. The mean calcaneal dual energy X-ray laser T-score of postmenopausal subjects who were smokers with a positive history of fracture, hormone replacement therapy (HRT), covered dressing style, lower educational level, no regular exercise habits, and low tea consumption was significantly lower than that obtained for the other group (p<0.05). A significant correlation was observed between the calcaneal dual energy X-ray laser T-score and age (r=-0.465, p=0.001), body mass index (BMI) (r=0.223, p=0.001), number of live births (r=-0.229, p=0.001), breast feeding time (r=-0.064, p=0.001), and age at menarche (r=-0.050, p=0.008). The correlations between calcaneal DXL and DXA T-scores (r=0.340, p=0.001) and calcaneal DXL and DXA Z-scores (r=0.360, p=0.001) at the spine, and calcaneal DXL and DXA T- ...


Subject(s)
Adult , Aged , Aged, 80 and over , Female , Humans , Middle Aged , Absorptiometry, Photon/methods , Bone Density/physiology , Calcaneus , Lasers , Osteoporosis , Body Mass Index , Calcaneus/physiology , Hip/physiology , Hip , Mass Screening , Risk Factors , Spine/physiology , Spine , Turkey
SELECTION OF CITATIONS
SEARCH DETAIL
...