1.
medRxiv ; 2024 May 12.
Article in English | MEDLINE | ID: mdl-38746343

ABSTRACT

In this work, we demonstrate the sodium magnetic resonance imaging (MRI) capabilities of a three-dimensional (3D) dual-echo ultrashort echo time (UTE) sequence with a novel rosette petal trajectory (PETALUTE), in comparison to the 3D density-adapted (DA) radial spokes UTE sequence. We scanned five healthy subjects using a 3D dual-echo PETALUTE acquisition and two comparable implementations of 3D DA-radial spokes acquisitions, one matching the number of k-space projections (Radial-Matched Trajectories) and the other matching the total number of samples (Radial-Matched Samples) acquired in k-space. The PETALUTE acquisition enabled equivalent sodium quantification in articular cartilage volumes of interest (168.8 ± 29.9 mM) to those derived from the 3D radial acquisitions (171.62 ± 28.7 mM and 149.8 ± 22.2 mM, respectively). We achieved a shorter scan time of 2:06 for 3D PETALUTE, compared to 3:36 for 3D radial acquisitions. We also evaluated the feasibility of further acceleration of the PETALUTE sequence through retrospective compressed sensing with 2× and 4× acceleration of the first echo and showed structural similarity of 0.89 ± 0.03 and 0.87 ± 0.03 when compared to non-retrospectively accelerated reconstruction. Together, these results demonstrate improved scan time with equivalent performance of the PETALUTE sequence compared to the 3D DA-radial sequence for sodium MRI of articular cartilage.

2.
Invest Radiol ; 2024 May 15.
Article in English | MEDLINE | ID: mdl-38747489

ABSTRACT

PURPOSE: Intraoral coils (IOCs) in magnetic resonance imaging (MRI) significantly improve the signal-to-noise ratio compared with conventional extraoral coils. To assess the safety of IOCs, we propose a 2-step procedure to evaluate radiofrequency-induced heating of IOCs and compare maximum temperature increases in 3 different types of IOCs. METHODS: The 2-step safety assessment consists of electric field measurements and simulations to identify local hotspots followed by temperature measurements during MRI. With this method, 3 different coil types (inductively coupled IFC, transmit/receive tLoop, and receive-only tLoopRx) were tested at 1.5 T and 3 T for both tuned and detuned coil states. High SAR and regular MRI protocols were applied for 2 coil positions. RESULTS: The measured E field maps display distinct hotspots for all tuned IOCs, which were reduced by at least 40-fold when the IOCs were detuned. Maximum temperature rise was higher when the coils were positioned at the periphery of the phantom with the coil planes parallel to B0. When neither active nor passive detuning was applied, maximum temperature increase of ΔT = 1.3/0.5/1.8 K was found for IFC/tLoop/tLoopRx coils. Hotspots detected by E field measurements, and simulations were consistent. In the simulations, the results were different for homogeneous phantoms compared with full anatomical models. The 2-step test procedure is applicable to different coil types. CONCLUSIONS: The results indicate that a risk for radiofrequency-induced heating exists for tuned IOCs, so that adequate detuning circuits need to be integrated in the coils to ensure safe operation.

3.
Z Med Phys ; 2023 Aug 07.
Article in English | MEDLINE | ID: mdl-37558527

ABSTRACT

OBJECTIVE: To investigate the feasibility of cerebral metabolic rate of oxygen consumption (CMRO2) measurements with MRI at 3 Tesla in different brain regions. METHODS: CMRO2 represents a key indicator of the physiological state of brain tissue. Dynamic 17O-MRI with inhalation of isotopically enriched 17O gas has been used to quantify global CMRO2 in brain white (WM) and gray matter (GM). However, global CMRO2 can only reflect the overall oxygen metabolism of the brain and cannot provide enough information on local tissue oxygen metabolism. To investigate the feasibility of determination of regional CMRO2 at a clinical 3 T MRI system, CMRO2 values in frontal, parietal and occipital WM and GM were determined in 5 healthy volunteers and compared to evaluate the regional differences of oxygen metabolism in WM and GM. Additionally, regional CMRO2 values were determined in deep brain structures including thalamus, dorsal striatum, caudate nucleus and insula cortex and in the cerebella, and compared with literature values from 15O-PET studies. RESULTS: In cortical GM the determined CMRO2 values were in good agreement with the literature, whereas values in WM were about 32-48% higher than literature values. Regional analysis revealed a significantly higher CMRO2 in the occipital GM compared to the frontal and parietal GM. By contrast, no significant difference of CMRO2 was observed across the WM. In addition, CMRO2 in deep brain structures was lower compared to literature values and in the cerebella a good hemispheric symmetry of the tissue oxygen metabolism was found. CONCLUSION: Dynamic 17O-MRI enables direct, non-invasive determination of regional CMRO2 in brain structures in healthy volunteers at 3T.

4.
Magn Reson Med ; 90(4): 1728-1737, 2023 10.
Article in English | MEDLINE | ID: mdl-37350426

ABSTRACT

PURPOSE: To improve intraoral transverse loop coil design for high-resolution dental MRI. METHODS: The transverse intraoral loop coil (tLoop) was modified (mtLoop) by overlapping the feed port conductors, bending the posterior section, introducing a parallel plate capacitor, optimizing the insulation thickness, and using it in receive-only mode. In addition, an MR-silent insulation was introduced. The performances of the mtLoop and tLoop coils were compared in terms of sensitivity, image SNR, and eddy currents using electromagnetic simulations and MRI measurements at 3T. RESULTS: The receive-only mode of the mtLoop increases the sensitivity at the apices of the roots, and the overlapped feed port design eliminated signal voids along the incisors. The bent posterior section with the parallel plate capacitor reduced the unwanted signal of the tongue by a factor of 2.3 in the selected region off interest and lowered the eddy currents by 10%. The proposed new coil provided higher SNR by elevenfold and 2.5-fold at the incisors and apices of the molar roots within the selected regions of interest, respectively, in the experiments, as well as improved comfort. Optimal insulation thickness was determined as 1 mm. With the mtLoop, a (250 µm)3 isotropic resolution of the dental arch could be realized using a UTE sequence within 2 min total acquisition time. A T2 -SPACE protocol with (350 µm)2 in-plane resolution was also demonstrated. CONCLUSION: The proposed new coil offers higher SNR at the incisors and apices of the molar roots, less unwanted signals from tongue, lower eddy currents, and improved patient comfort.


Subject(s)
Magnetic Resonance Imaging , Radio Waves , Humans , Equipment Design , Phantoms, Imaging , Magnetic Resonance Imaging/methods
5.
MAGMA ; 36(3): 439-449, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37195365

ABSTRACT

OBJECTIVE: Low-field MRI systems are expected to cause less RF heating in conventional interventional devices due to lower Larmor frequency. We systematically evaluate RF-induced heating of commonly used intravascular devices at the Larmor frequency of a 0.55 T system (23.66 MHz) with a focus on the effect of patient size, target organ, and device position on maximum temperature rise. MATERIALS AND METHODS: To assess RF-induced heating, high-resolution measurements of the electric field, temperature, and transfer function were combined. Realistic device trajectories were derived from vascular models to evaluate the variation of the temperature increase as a function of the device trajectory. At a low-field RF test bench, the effects of patient size and positioning, target organ (liver and heart) and body coil type were measured for six commonly used interventional devices (two guidewires, two catheters, an applicator and a biopsy needle). RESULTS: Electric field mapping shows that the hotspots are not necessarily localized at the device tip. Of all procedures, the liver catheterizations showed the lowest heating, and a modification of the transmit body coil could further reduce the temperature increase. For common commercial needles no significant heating was measured at the needle tip. Comparable local SAR values were found in the temperature measurements and the TF-based calculations. CONCLUSION: At low fields, interventions with shorter insertion lengths such as hepatic catheterizations result in less RF-induced heating than coronary interventions. The maximum temperature increase depends on body coil design.


Subject(s)
Heating , Radio Waves , Humans , Magnetic Resonance Imaging/methods , Temperature , Phantoms, Imaging , Hot Temperature
6.
J Trace Elem Med Biol ; 77: 127146, 2023 May.
Article in English | MEDLINE | ID: mdl-36871432

ABSTRACT

BACKGROUND: The iron concentration increases during normal brain development and is identified as a risk factor for many neurodegenerative diseases, it is vital to monitor iron content in the brain non-invasively. PURPOSE: This study aimed to quantify in vivo brain iron concentration with a 3D rosette-based ultra-short echo time (UTE) magnetic resonance imaging (MRI) sequence. METHODS: A cylindrical phantom containing nine vials of different iron concentrations (iron (II) chloride) from 0.5 millimoles to 50 millimoles and six healthy subjects were scanned using 3D high-resolution (0.94 ×0.94 ×0.94 mm3) rosette UTE sequence at an echo time (TE) of 20 µs. RESULTS: Iron-related hyperintense signals (i.e., positive contrast) were detected based on the phantom scan, and were used to establish an association between iron concentration and signal intensity. The signal intensities from in vivo scans were then converted to iron concentrations based on the association. The deep brain structures, such as the substantia nigra, putamen, and globus pallidus, were highlighted after the conversion, which indicated potential iron accumulations. CONCLUSION: This study suggested that T1-weighted signal intensity could be used for brain iron mapping.


Subject(s)
Iron , Magnetic Resonance Imaging , Humans , Magnetic Resonance Imaging/methods , Brain/diagnostic imaging , Brain Mapping/methods , Contrast Media
7.
Magn Reson Med ; 89(3): 1237-1250, 2023 03.
Article in English | MEDLINE | ID: mdl-36226654

ABSTRACT

PURPOSE: To introduce an RF coil system consisting of an 8-channel transmit (Tx) and 8-channel receive (Rx) coil arrays for 19 F MRI of large animals. METHODS: The Tx efficiency and homogeneity of the 8-element loop coil array (loop size: 6 × 15 cm2 ) were simulated for two different pig models rendered from MR images. An 8-channel Rx coil array consisting of a flexible 6-channel posterior and a 2-channel planar anterior array was designed to fit on the abdomen of an average-sized pig in supine position. Measurements were performed in a grid phantom and ex vivo on a pig model with perfluoroctylbromide (PFOB)-filled tubes inserted in the thorax. RESULTS: Measured and simulated Tx efficiency and homogeneity for the 8-channel and 5-channel arrays were in good agreement: 1.87 ± 0.22µT/√kW versus 1.96 ± 0.29µT/√kW, and 2.29 ± 0.39µT/√kW versus 2.41 ± 0.37µT/√kW. An isolation of 38 ± 8 dB is achieved between the 19 F Tx and Rx elements, and over 30 dB between the 1 H and 19 F elements. The PFOB-filled vials could be clearly identified within the cadaver abdomen with an SNR of 275 ± 51 for a 3D gradient-echo sequence with 2-mm isotropic resolution and 12 averages, acquired in 9:52 min:s. Performance of the Tx array was robust against phase and amplitude mismatches at the input ports. CONCLUSIONS: A modular and scalable Tx array offers improved Tx efficiency in 19 F MRI of large animals with various sizes. Although conventional birdcage coils have superior Tx efficiency within the target region of interest, scalability of the Tx array to animal size is a major benefit. The described 19 F coil provides homogeneous excitation and high sensitivity detection in large pig models.


Subject(s)
Magnetic Resonance Imaging , Radio Waves , Animals , Swine , Signal-To-Noise Ratio , Equipment Design , Phantoms, Imaging , Magnetic Resonance Imaging/veterinary , Magnetic Resonance Imaging/methods
8.
Magn Reson Med ; 89(2): 508-521, 2023 02.
Article in English | MEDLINE | ID: mdl-36161728

ABSTRACT

PURPOSE: This study aimed to develop a new 3D dual-echo rosette k-space trajectory, specifically designed for UTE MRI applications. The imaging of the ultra-short transverse relaxation time (uT2 ) of brain was acquired to test the performance of the proposed UTE sequence. THEORY AND METHODS: The rosette trajectory was developed based on rotations of a "petal-like" pattern in the kx -ky plane, with oscillated extensions in the kz -direction for 3D coverage. Five healthy volunteers underwent 10 dual-echo 3D rosette UTE scans with various TEs. Dual-exponential complex model fitting was performed on the magnitude data to separate uT2 signals, with the output of uT2 fraction, uT2 value, and long-T2 value. RESULTS: The 3D rosette dual-echo UTE sequence showed better performance than a 3D radial UTE acquisition. More significant signal intensity decay in white matter than gray matter was observed along with the TEs. The white matter regions had higher uT2 fraction values than gray matter (10.9% ± 1.9% vs. 5.7% ± 2.4%). The uT2 value was approximately 0.10 ms in white matter . CONCLUSION: The higher uT2 fraction value in white matter compared to gray matter demonstrated the ability of the proposed sequence to capture rapidly decaying signals.


Subject(s)
Magnetic Resonance Imaging , White Matter , Humans , Magnetic Resonance Imaging/methods , Brain/diagnostic imaging , Gray Matter/diagnostic imaging , Healthy Volunteers , Imaging, Three-Dimensional
9.
Front Psychol ; 13: 844032, 2022.
Article in English | MEDLINE | ID: mdl-36544443

ABSTRACT

Breath control is an important factor for singing voice production, but pedagogic descriptions of how a beneficial movement pattern should be performed vary widely and the underlying physiological processes are not understood in detail. Differences in respiratory movements during singing might be related to the sex of the singer. To study sex-related differences in respiratory kinematics during phonation, 12 singers (six male and six female) trained in the Western classical singing tradition were imaged with dynamic magnetic resonance imaging. Singers were asked to sustain phonation at five different pitches and loudness conditions, and cross-sectional images of the lung were acquired. In each dynamic image frame the distances between anatomical landmarks were measured to quantify the movements of the respiratory apparatus. No major difference between male and female singers was found for the general respiratory kinematics of the thorax and the diaphragm during sustained phonation. However when compared to sole breathing, male singers significantly increased their thoracic movements for singing. This behavior could not be observed in female singers. The presented data support the hypothesis that professional singers follow sex-specific breathing strategies. This finding may be important in a pedagogical context where the biological sex of singer and student differ and should be further investigated in a larger cohort.

10.
Z Med Phys ; 2022 Oct 31.
Article in English | MEDLINE | ID: mdl-36328861

ABSTRACT

PURPOSE: To maximize acquisition bandwidth in zero echo time (ZTE) sequences, readout gradients are already switched on during the RF pulse, creating unwanted slice selectivity. The resulting image distortions are amplified especially when the anatomy of interest is not located at the isocenter. We aim to characterize off-center ZTE MRI of extremities such as the shoulder, knee, and hip, adjusting the carrier frequency of the RF pulse excitation for each TR. METHODS: In ZTE MRI, radial encoding schemes are used, where the distorted slice profile due to the finite RF pulse length rotates with the k-space trajectory. To overcome these modulations for objects far away from the magnet isocenter, the frequency of the RF pulse is shifted for each gradient setting so that artifacts do not occur at a given off-center target position. The sharpness of the edges in the images were calculated and the ZTE acquisition with off-center excitation was compared to an acquisition with isocenter excitation both in phantom and in vivo off-center MRI of the shoulder, knee, and hip at 1.5 and 3T MRI systems. RESULTS: Distortion and blurriness artifacts on the off-center MRI images of the phantom, in vivo shoulder, knee, and hip images were mitigated with off-center excitation without time or noise penalty, at no additional computational cost. CONCLUSION: The off-center excitation allows ZTE MRI of the shoulder, knee, and hip for high-bandwidth image acquisitions for clinical settings, where positioning at the isocenter is not possible.

11.
Magn Reson Med ; 87(6): 2685-2696, 2022 06.
Article in English | MEDLINE | ID: mdl-35037292

ABSTRACT

PURPOSE: To accelerate the Pointwise Encoding Time Reduction with Radial Acquisition (PETRA) sequence using compressed sensing while preserving the image quality for high-resolution MRI of tissue with ultra-short T2∗ values. METHODS: Compressed sensing was introduced in the PETRA sequence (csPETRA) to accelerate the time-consuming single point acquisition of the k-space center data. Random undersampling was applied to achieve acceleration factors up to Acc = 32. Phantom and in vivo images of the knee joint of six volunteers were measured at 3T using csPETRA sequence with Acc = 4, 8, 12, 16, 24, and 32. Images were compared against fully sampled PETRA data (Acc = 1) for structural similarity and normalized-mean-square-error. Qualitative and semi-quantitative analyses were performed to assess the effect of the acceleration on image artifacts, image quality, and delineation of anatomical structures at the knee. RESULTS: Even at high acceleration factors of Acc = 16 no aliasing artifacts were observed, and the anatomical details were preserved compared with the fully sampled data. The normalized-mean-square-error was less than 1% for Acc = 16, in which single point imaging acquisition time was reduced from 165 to 10 s, reducing the total scan time from 7.8 to 5.2 min. Semi-quantitative analyses suggest that Acc = 16 yields comparable diagnostic quality as the fully sampled data for knee imaging at a scan time of 5.2 min. CONCLUSION: csPETRA allows for ultra-short T2∗ imaging of the knee joint in clinically acceptable scan times while maintaining the image quality of original non-accelerated PETRA sequence.


Subject(s)
Artifacts , Magnetic Resonance Imaging , Humans , Image Processing, Computer-Assisted/methods , Knee Joint/diagnostic imaging , Magnetic Resonance Imaging/methods , Phantoms, Imaging
12.
Invest Radiol ; 57(3): 163-170, 2022 03 01.
Article in English | MEDLINE | ID: mdl-34510099

ABSTRACT

OBJECTIVES: Accurate visualization of dental root canals is vital for the correct diagnosis and subsequent treatment. This work assesses the improvement of a dedicated new coil for dental magnetic resonance imaging (MRI) in comparison to conventional ones in terms of signal-to-noise ratio (SNR) and visibility. MATERIALS AND METHODS: A newly developed intraoral flexible coil was used to display dental roots with MRI, and it provides improved sensitivity with a loop design and size adjusted to a single tooth anatomy. Ex vivo and in vivo measurements were performed on a 3 T clinical MR system, and results were compared with conventional head and surface coil images. Additional comparison was performed with a modified fast spin echo sequence and a constructive interference in steady-state sequence. RESULTS: Ex vivo, an SNR gain of 6.3 could be achieved with the intraoral flexible coil setup, and higher visibility down to 200 µm was possible, whereas the external loop coil is limited to 400 µm. In vivo measurements in a volunteer resulted in an SNR gain of up to 4.5 with an improved delineation of the root canals, especially for the branch tissue splitting of the mesial root canal into mesial-buccal and mesial-lingual. CONCLUSIONS: In summary, we showed the feasibility of implementing a wireless coil approach with readily available dental practice materials for sealing and placement. Highly improved MRI scans can be acquired within clinically feasible scan times, and this might provide additional medical findings to supplement available x-ray images.


Subject(s)
Dental Pulp Cavity , Magnetic Resonance Imaging , Dental Pulp Cavity/diagnostic imaging , Equipment Design , Humans , Magnetic Resonance Imaging/methods , Phantoms, Imaging , Signal-To-Noise Ratio
13.
MAGMA ; 35(2): 301-310, 2022 Apr.
Article in English | MEDLINE | ID: mdl-34542771

ABSTRACT

OBJECTIVE: The slow spatial encoding of MRI has precluded its application to rapid physiologic motion in the past. The purpose of this study is to introduce a new fast acquisition method and to demonstrate feasibility of encoding rapid two-dimensional motion of human vocal folds with sub-millisecond resolution. METHOD: In our previous work, we achieved high temporal resolution by applying a rapidly switched phase encoding gradient along the direction of motion. In this work, we extend phase encoding to the second image direction by using single-point imaging with rapid encoding (SPIRE) to image the two-dimensional vocal fold oscillation in the coronal view. Image data were gated using electroglottography (EGG) and motion corrected. An iterative reconstruction with a total variation (TV) constraint was used and the sequence was also simulated using a motion phantom. RESULTS: Dynamic images of the vocal folds during phonation at pitches of 150 and 165 Hz were acquired in two volunteers and the periodic motion of the vocal folds at a temporal resolution of about 600 µs was shown. The simulations emphasize the necessity of SPIRE for two-dimensional motion encoding. DISCUSSION: SPIRE is a new MRI method to image rapidly oscillating structures and for the first time provides dynamic images of the vocal folds oscillations in the coronal plane.


Subject(s)
Magnetic Resonance Imaging , Vocal Cords , Humans , Imaging, Three-Dimensional/methods , Magnetic Resonance Imaging/methods , Motion , Movement , Phantoms, Imaging , Vocal Cords/diagnostic imaging
14.
Sci Rep ; 11(1): 22965, 2021 11 25.
Article in English | MEDLINE | ID: mdl-34824315

ABSTRACT

Respiratory kinematics are important for the regulation of voice production. Dynamic MRI is an excellent tool to study respiratory motion providing high-resolution cross-sectional images. Unfortunately, in clinical MRI systems images can only be acquired in a horizontal subject position, which does not take into account gravitational effects on the respiratory apparatus. To study the effect of body posture on respiratory kinematics during phonation, 8 singers were examined both in an open-configuration MRI with a rotatable gantry and a conventional horizontal MRI system. During dynamic MRI the subjects sang sustained tones at different pitches in both supine and upright body positions. Sagittal images of the respiratory system were obtained at 1-3 images per second, from which 6 anatomically defined distances were extracted to characterize its movements in the anterior, medium and posterior section of the diaphragm as well as the rip cage (diameter at the height of the 3rd and 5th rip) and the anterior-posterior position of the diaphragm cupola. Regardless of body position, singers maintained their general principles of respiratory kinematics with combined diaphragm and thorax muscle activation for breath support. This was achieved by expanding their chest an additional 20% during inspiration when singing in the supine position but not for sole breathing. The diaphragm was cranially displaced in supine position for both singing and breathing and its motion range increased. These results facilitate a more realistic extrapolation of research data obtained in a supine position.


Subject(s)
Gravitation , Magnetic Resonance Imaging/methods , Phonation/physiology , Respiratory System , Adult , Biomechanical Phenomena , Diaphragm/diagnostic imaging , Female , Humans , Male , Motion , Posture , Respiration , Respiratory Rate , Respiratory System/diagnostic imaging , Singing/physiology , Supine Position
15.
Phys Med ; 88: 1-8, 2021 Aug.
Article in English | MEDLINE | ID: mdl-34147868

ABSTRACT

PURPOSE: To quantify B0- and B1-induced imaging artifacts of braided venous stents and to compare the artifacts to a set of laser-cut stents used in venous interventions. METHODS: Three prototypes of braided venous stents with different geometries were tested in vitro. B0 field distortion maps were measured via the frequency shift Δf using multi-echo imaging. B1 distortions were quantified using the double angle method. The relative amplitudes B1rel were calculated to compare the intraluminal alteration of B1. Measurements were repeated with the stents in three different orientations: parallel, diagonal and orthogonal to B0. RESULTS: At 1.5 T, the braided stents induced a maximum frequency shift of Δfx<100Hz. Signal voids were limited to a distance of 2 mm to the stent walls at an echo time of 3 ms. No substantial difference in the B0 field distortions was seen between laser-cut and braided venous stents. B1rel maps showed strongly varying distortion patterns in the braided stents with the mean intraluminal B1rel ranging from 63±18% in prototype 1 to 98±38% in prototype 2. Compared to laser-cut stents the braided stents showed a 5 to 9 times higher coefficient of variation of the intraluminal B1rel. CONCLUSION: Braided venous stent prototypes allow for MR imaging of the intraluminal area without substantial signal voids due to B0-induced artifacts. Whereas B1 is attenuated homogeneously in laser-cut stents, the B1 distortion in braided stents is more inhomogeneous and shows areas with enhanced amplitude. This could potentially be used in braided stent designs for intraluminal signal amplification.


Subject(s)
Artifacts , Stents , Lasers , Magnetic Resonance Imaging
16.
IEEE Trans Biomed Eng ; 68(8): 2563-2573, 2021 08.
Article in English | MEDLINE | ID: mdl-33513097

ABSTRACT

OBJECTIVE: In dental MRI, intraoral coils provide higher signal-to-noise ratio (SNR) than coils placed outside the mouth. This study aims to design an intraoral dipole antenna and demonstrates the feasibility of combining it with an extraoral coil. METHODS: Dipole antenna design was chosen over loop design, as it is open toward the distal; therefore, it does not restrain tongue movement. The dipole design offers also an increased depth-of-sensitivity that allows for MRI of dental roots. Different dipole antenna designs were simulated using a finite-difference-time-domain approach. Ribbon, wire, and multi-wire arms were compared. The best design was improved further by covering the ends of the dipole arms with a high-permittivity material. Phantom and in vivo measurements were conducted on a 3T clinical MRI system. RESULTS: The best transmit efficiency and homogeneity was achieved with a multi-wire curved dipole antenna with 7 wires for each arm. With an additional high-permittivity cap the transmit field inhomogeneity was further reduced from 20% to 5% along the dipole arm. When combined with extraoral flexible surface-coil, the coupling between the coils was less than -32dB and SNR was increased. CONCLUSION: Using intraoral dipole design instead of loop improves patient comfort. We demonstrated feasibility of the intraoral dipole combined with an extraoral flexible coil-array for dental MRI. Dipole antenna enabled decreasing imaging field-of-view, and reduced the prevalent signal from tongue. SIGNIFICANCE: This study highlights the advantages and the main challenges of the intraoral RF coils and describes a novel RF coil that addresses those challenges.


Subject(s)
Magnetic Resonance Imaging , Radio Waves , Equipment Design , Humans , Phantoms, Imaging , Signal-To-Noise Ratio
17.
IEEE Trans Biomed Eng ; 68(3): 783-792, 2021 03.
Article in English | MEDLINE | ID: mdl-32746061

ABSTRACT

OBJECTIVE: To assess the effect of the electro-magnetic coupling of endovascular stents on their RF heating potential in MRI. METHODS: A custom-built electro-optic E-field probe is used to perform measurements of the scattered E-field at a distance of 2 mm to stent samples with submillimeter resolution. Various combinations of stent lengths are measured at 124 MHz (3T MRI Larmor frequency) with varying gap and overlap between the stents, with and without stent coating, and with distilled water and saline solution as surrounding media. The results are compared to theoretically derived E-field distributions. RESULTS: At an overlap of 10 mm the E-field pattern of two stents collapses to a single dipole indicating excellent coupling between the stents. E-field intensities substantially increase/decrease up to 5-fold/2.5-fold if the total length of the two combined stents is closer/further away from the resonance length of the single stents. Stent coating and conductivity of the surrounding medium strongly influence the E-field patterns of overlapping stents. Measured and calculated E-field patterns are in good agreement. CONCLUSION: Electro-optic E-field measurements are a valuable tool for RF safety assessments in both single as well as coupled stents. SIGNIFICANCE: RF induced heating of single stents during MRI has been extensively studied. However, in clinical practice often two or more stents are implanted in close proximity which can substantially change the pattern of the scattered electric fields and the localization and intensity of hot spots. In this study a detailed assessment of the coupling of stents during RF excitation is given.


Subject(s)
Magnetic Resonance Imaging , Stents , Electricity , Heating , Radio Waves
18.
Z Med Phys ; 31(1): 65-72, 2021 Feb.
Article in English | MEDLINE | ID: mdl-32873440

ABSTRACT

The quantification of myocardial perfusion with contrast agent (CA) tracers requires the precise knowledge of the arterial input function (AIF). In this study a method for MR-guided vascular interventions is evaluated that determines the AIF via an active tracking catheter during targeted CA injection. A phantom experiment with a dialysis filter was conducted to measure the AIF using an active catheter and a dynamic image series as reference. To compensate for dilution and coil sensitivity effects, correction methods were developed for the catheter-based AIF determination. From the dynamic MR measurements in the perfusion phantom quantitative perfusion maps were calculated by a deconvolution of the measured CA concentration with the AIF, and additional flow measurements were used to normalize the perfusion map. The signal-time-curves of the measured AIF using the catheter-based and imaging-based methods agree while the absolute values differ by a scaling factor of about 9. After normalization to the surrounding flow, both perfusion techniques are in excellent agreement. Catheter-based AIF measurements are feasible but require an additional normalization which can be determined from a flow measurement. The technique might enable faster perfusion measurements during cardiovascular interventions.


Subject(s)
Arteries/diagnostic imaging , Arteries/physiology , Catheters , Magnetic Resonance Imaging/instrumentation , Humans
19.
PLoS One ; 15(12): e0244539, 2020.
Article in English | MEDLINE | ID: mdl-33382744

ABSTRACT

The respiratory system is a central part of voice production as it contributes to the generation of subglottic pressure, which has an impact on voice parameters including fundamental frequency and sound pressure level. Both parameters need to be adjusted precisely during complex phonation tasks such as singing. In particular, the underlying functions of the diaphragm and rib cage in relation to the phonation of pitch jumps are not yet understood in detail. This study aims to analyse respiratory movements during phonation of pitch jumps using dynamic MRI of the lungs. Dynamic images of the breathing apparatus of 7 professional singers were acquired in the supine position during phonation of upwards and downwards pitch jumps in a high, medium, and low range of the singer's tessitura. Distances between characteristic anatomical landmarks in the lung were measured from the series of images obtained. During sustained phonation, the diaphragm elevates, and the rib cage is lowered in a monotonic manner. During downward pitch jumps the diaphragm suddenly changed its movement direction and presented with a short inspiratory activation which was predominant in the posterior part and was associated with a shift of the cupola in an anterior direction. The magnitude of this inspiratory movement was greater for jumps that started at higher compared to lower fundamental frequency. In contrast, expiratory movement of the rib cage and anterior diaphragm were simultaneous and continued constantly during the jump. The data underline the theory of a regulation of subglottic pressure via a sudden diaphragm contraction during phonation of pitch jumps downwards, while the rib cage is not involved in short term adaptations. This strengthens the idea of a differentiated control of rib cage and diaphragm as different functional units during singing phonation.


Subject(s)
Glottis/physiology , Lung/diagnostic imaging , Magnetic Resonance Imaging/methods , Singing , Adult , Biomechanical Phenomena , Diaphragm/physiology , Female , Humans , Lung/physiology , Male , Pilot Projects , Pressure
20.
J Magn Reson ; 319: 106825, 2020 10.
Article in English | MEDLINE | ID: mdl-32947127

ABSTRACT

In Magnetic Resonance Imaging (MRI), radio frequency (RF) coils of different forms and shapes are used to maximize signal-to-noise ratio (SNR). RF coils are designed for clinical applications and have dimensions comparable with the target body part to be imaged, and they perform best when loaded by human tissue majority of which have conductivity values higher than 0.5 S/m. However, they are not properly tuned and matched for samples having low conductivity such as solid samples with low water content. Moreover, for samples with low filling factor and low conductivity, the noise in MRI is dominated by RF coil losses. In this case, RF coil design can be optimized to improve image SNR. Here, a new software tool (Multi-parameter Analytical Method for B1 and SNR Analysis) MAMBA is presented to design and compare volume coils of birdcage, solenoid, and loop-gap design for these samples. The input parameters of the tool are the sample properties, the coil design and the hardware properties, of which a relative SNR is determined. For that, a figure of merit is calculated from the coil sensitivity, applied resonant frequency and the resistive losses of sample, coil and capacitive components. The tool was tested in an ancient Egyptian mummy head which represents an extreme case of MRI with short T2*. Two optimized birdcage coils were designed using MAMBA, constructed and compared to a commercial transmit receive head coil. Calculated relative SNR values are in good agreement with the measurements.