1.
Materials (Basel) ; 14(19)2021 Sep 28.
Article in English | MEDLINE | ID: mdl-34640025

ABSTRACT

The demand for composite materials in high-voltage electrical insulation is escalating over the last decades. In the power system, the composite glass-fiber-reinforced polymer has been used as an alternative to wood and steel crossarm structures due to its superior properties. As a composite, the material is susceptible to multi-aging factors, one of which is the electrical stress caused by continuous and temporary overvoltage. In order to achieve a better insulation performance and higher life expectancy, the distribution of the stresses should firstly be studied and understood. This paper focuses on the simulation work to better understand the stress distribution of the polyurethane foam-filled glass-fiber-reinforced polymer crossarm due to the lightning transient injection. A finite-element-based simulation was carried out to investigate the behavior of the electric field and voltage distribution across the sample using an Ansys Maxwell 3D. Electrical stresses at both outer and inner surfaces of the crossarm during the peak of lightning were analyzed. Analyses on the electric field and potential distribution were performed at different parts of the crossarm and correlated to the physical characteristics and common discharge location observed during the experiment. The results of the electric field on the crossarm indicate that both the outer and internal parts of the crossarm were prone to high field stress.

2.
PLoS One ; 16(9): e0256298, 2021.
Article in English | MEDLINE | ID: mdl-34492042

ABSTRACT

Grounding systems are critical in safeguarding people and equipment from power system failures. A grounding system's principal goal is to offer the lowest impedance path for undesired fault current. Optimization of the grounding grid designs is important in satisfying the minimum cost of the grounding system and safeguarding those people who work in the surrounding area of the grounded installations. Currently, there is no systematic guidance or standard for grounding grid designs that include two-layer soil and its effects on grounding grid systems, particularly vertically layered soil. Furthermore, while numerous studies have been conducted on optimization, relatively limited study has been done on the problem of optimizing the grounding grid in two-layer soil, particularly in vertical soil structures. This paper presents the results of optimization for substation grounding systems using the Simulated Annealing (SA) algorithm in different soil conditions which conforms to the safety requirements of the grounding system. Practical features of grounding grids in various soil conditions discussed in this paper (uniform soil, two-layer horizontal soil, and two-layer vertical soil) are considered during problem formulation and solution algorithm. The proposed algorithm's results show that the number of grid conductors in the X and Y directions (Nx and Ny), as well as vertical rods (Nr), can be optimized from initial numbers of 35% for uniform soil, 57% for horizontal two-layer soil for ρ1> ρ2, and 33% for horizontal two-layer soil for ρ1< ρ2, and 29% for vertical two-layer soil structure. In other words, the proposed technique would be able to utilize square and rectangle-shaped grounding grids with a number of grid conductors and vertical rods to be implemented in uniform, two-layer horizontal and vertical soil structure, depending on the resistivity of the soil layer.


Subject(s)
Power Plants/standards , Soil/chemistry , Algorithms , Computer Simulation , Electric Conductivity , Electric Impedance , Models, Theoretical , Spatial Analysis
3.
Materials (Basel) ; 14(7)2021 Mar 29.
Article in English | MEDLINE | ID: mdl-33805583

ABSTRACT

The fourth rail transit is an interesting topic to be shared and accessed by the community within that area of expertise. Several ongoing works are currently being conducted especially in the aspects of system technical performances including the rail bracket component and the sensitivity analyses on the various rail designs. Furthermore, the lightning surge study on railway electrification is significant due to the fact that only a handful of publications are available in this regard, especially on the fourth rail transit. For this reason, this paper presents a study on the electrical performance of a fourth rail Direct Current (DC) urban transit affected by an indirect lightning strike. The indirect lightning strike was modelled by means of the Rusck model and the sum of two Heidler functions. The simulations were carried out using the EMTP-RV software which included the performance comparison of polymer-insulated rail brackets, namely the Cast Epoxy (CE), the Cycloaliphatic Epoxy A (CEA), and the Glass Reinforced Plastic (GRP) together with the station arresters when subjected by 30 kA (5/80 µs) and 90 kA (9/200 µs) lightning currents. The results obtained demonstrated that the GRP material has been able to slightly lower its induced overvoltage as compared to other materials, especially for the case of 90 kA (9/200 µs), and thus serves better coordination with the station arresters. This improvement has also reflected on the recorded residual voltage and energy absorption capacity of the arrester, respectively.

4.
F1000Res ; 10: 1136, 2021.
Article in English | MEDLINE | ID: mdl-35387277

ABSTRACT

Background: There has been rising concern amongst the public regarding their home's proximity to high tension power transmission lines. The primary cause of fear is the impact of the electromagnetic interference (EMI) radiation on the nearby occupants' health. Despite the presence of national permissible limits of EMI radiation, there is still lack of information with regards to the EMI radiation of the types of power lines configuration in Malaysia. Methods: The electric and magnetic fields of several selected power transmission lines were simulated using the EMFACDC software program from the recommendation ITU-T K.90. Five types of power transmission lines available in Malaysia are considered. Results: It was found that the simulated electric and magnetic field levels at all the power lines' right of way (ROW) boundary complies with the prescribed exposure limit. However, the electromagnetic fields (EMF) level increases significantly as the separation distance is reduced from 30m. For a more conservative approach, the ROW can be set at 30m across all transmission voltage level and corridor area condition. Conclusion: It can be concluded that Malaysia's power transmission lines are within the prescribed exposure limits. To further minimize the electric and magnetic field level, it is recommended that the residential building should be built at least 30 meters away from the power transmission lines, especially for the 275kV double circuit, 275/132kV quadruple circuit, and 500kV double circuit lines.


Subject(s)
Electromagnetic Fields , Environmental Exposure , Electromagnetic Fields/adverse effects , Environmental Exposure/analysis , Malaysia
5.
Nanotechnology ; 31(42): 425708, 2020 Aug 04.
Article in English | MEDLINE | ID: mdl-32748802

ABSTRACT

In this paper, the effect of different types of surfactants on the lightning breakdown voltages of palm oil (PO) and coconut oil (CO) based aluminium oxide (Al2O3) nanofluids is investigated. Three different types of surfactants were used in this study known as cationic (cetyl trimethyl ammonium bromide (CTAB)), anionic (sodium dodecyl sulfate (SDS)) and non-ionic (oleic acid (OA)). The volume percentage concentrations of Al2O3 dispersed into PO and CO were varied from 0.001% to 0.05%. The ratio of surfactant to the nanoparticles was set to 50% from the volume concentration of nanoparticles which equivalent to 1:2. In total, two types of refined, bleached and deodorized palm oil (RBDPO) and one type of CO were examined for lightning breakdown voltage. The test was carried out based on needle-sphere electrodes configuration with 25 mm gap distance. The presence of Al2O3 improves both positive and negative lightning breakdown voltages of RBDPO and CO. Under the positive and negative polarities, the CTAB does provide further improvements on the lightning breakdown voltages of RBDPOA (1st type of samples) and CO at most of the volume of concentration of Al2O3. SDS and OA could also further improve the lightning breakdown voltage of CO at certain volume concentration of Al2O3. On the other hand, the lightning breakdown voltage of RBDPOB based Al2O3 nanofluid (2nd type of samples) does not further improve with the introduction of surfactants. At most of the volume concentration of Al2O3, the introduction of CTAB further increases the times to breakdown and decrease the average streamer velocities of RBDPOA under both polarities. The same finding is observed for CO under positive polarity with CTAB and SDS as well as under negative polarity in the presence of all surfactants. The streamer velocities and times to breakdown patterns of RBDPOB based Al2O3 nanofluid are inconsistent in the presence of all surfactants. It is found that RBDPO and CO based Al2O3 nanofluids have second mode of streamer whereby the streamer velocities are from 1 km s-1 to 1.63 km s-1 regardless with or without surfactants.

6.
Materials (Basel) ; 11(4)2018 Mar 30.
Article in English | MEDLINE | ID: mdl-29601520

ABSTRACT

This paper presents a sealed ageing study of palm oil (PO) and coconut oil (CO) in the presence of insulation paper. The type of PO under study is refined, bleached, and deodorized palm oil (RBDPO) olein. Three different variations of RBDPO and one sample of CO are aged at temperatures of 90 °C, 110 °C, and 130 °C. The properties of RBDPO and CO as well as paper under ageing are then analysed through dielectric and physicochemical measurements. It is found that the effect of ageing is not significant on the alternating current (AC) breakdown voltages and relative permittivities of RBDPO and CO. There is a slight increment trend of the resistivity for CO, while for all of the RBDPO, the resistivity slightly decreases as the ageing progresses. Only CO shows an apparent reduction of the dielectric dissipation factor. Throughout the ageing time, the acidities of all of the RBDPO and CO remain at low level, while the moisture in oils decreases. The tensile index (TI) of the papers for all of the RBDPO and CO retain more than 50% of the TI. A significant increment of the paper ageing rates of all of the RBDPO and CO is observed at an ageing temperature of 130 °C.

7.
PLoS One ; 12(11): e0187892, 2017.
Article in English | MEDLINE | ID: mdl-29136025

ABSTRACT

Located near the equator, Malaysia is a country with one of the highest lightning densities in the world. Lightning contributes to 70% of the power outages in Malaysia and affects power equipment, automated network systems, causes data losses and monetary losses in the nation. Therefore, consideration of insulator evaluation under lightning impulses can be crucial to evaluate and attempt to overcome this issue. This paper presents a new approach to increase the electrical performance of polymer insulators using a Room Temperature Vulcanisation (RTV) coating. The evaluation involves three different settings of polymer insulator, namely uncoated, RTV type 1, and RTV type 2 upper surface coatings. All the insulators were tested under three different conditions as dry, clean wet and salty under different impulse polarities using the even-rising test method. The voltage breakdown for each test was recorded. From the experiment, it was found that the effectiveness of the RTV coating application became apparent when tested under salty or polluted conditions. It increased the voltage withstand capabilities of the polymer insulator up to 50% from the basic uncoated insulator. Under dry and clean conditions, the RTV coating provided just a slight increase of the breakdown voltage. The increase in voltage breakdown capability decreased the probability of surface discharge and dry band arcing that could cause degradation of the polymeric material housing. The RTV type 1 coating was found to be more effective when performing under a lightning impulse. The findings might help the utility companies improve the performance of their insulators in order to increase power system reliability.


Subject(s)
Electric Power Supplies , Electricity , Polymers/chemistry , Malaysia
8.
PLoS One ; 12(2): e0172118, 2017.
Article in English | MEDLINE | ID: mdl-28234930

ABSTRACT

Protection of medium voltage (MV) overhead lines against the indirect effects of lightning is an important issue in Malaysia and other tropical countries. Protection of these lines against the indirect effects of lightning is a major concern and can be improved by several ways. The choice of insulator to be used for instance, between the glass, ceramic or polymer, can help to improve the line performance from the perspective of increasing the breakdown strength. In this paper, the electrical performance of a 10 kV polymer insulator under different conditions for impulse, weather and insulator angle with respect to a cross-arm were studied (both experimental and modelling) and the results were discussed accordingly. Results show that the weather and insulator angle (with respect to the cross-arm) are surprisingly influenced the values of breakdown voltage and leakage current for both negative and positive impulses. Therefore, in order to select a proper protection system for MV lines against lightning induced voltage, consideration of the local information concerning the weather and also the insulator angles with respect to the cross-arm are very useful for line stability and performance.


Subject(s)
Electricity , Lightning , Polymers , Equipment Design , Malaysia , Models, Statistical , Physical Phenomena , Weather
9.
PLoS One ; 11(4): e0152661, 2016.
Article in English | MEDLINE | ID: mdl-27035716

ABSTRACT

The influence of pre-slaughter electrical stunning techniques and slaughter without stunning on bleeding efficiency and shelf life of chevon during a 14 d postmortem aging were assessed. Thirty two Boer crossbred bucks were randomly assigned to four slaughtering techniques viz slaughter without stunning (SWS), low frequency head-only electrical stunning (LFHO; 1 A for 3 s at a frequency of 50 Hz), low frequency head-to-back electrical stunning (LFHB; 1 A for 3 s at a frequency of 50 Hz) and high frequency head-to-back electrical stunning (HFHB; 1 A for 3 s at a frequency of 850 Hz). The SWS, LFHO and HFHB goats had higher (p<0.05) blood loss and lower residual hemoglobin in muscle compared to LFHB. The LFHB meat had higher (p<0.05) TBARS value than other treatments on d 7 and 14 d postmortem. Slaughtering methods had no effect on protein oxidation. Higher bacterial counts were observed in LFHB meat compared to those from SWS, LFHO and HFHB after 3 d postmortem. Results indicate that the low bleed-out in LFHB lowered the lipid oxidative stability and microbiological quality of chevon during aging.


Subject(s)
Meat Products/microbiology , Animals , Colony Count, Microbial , Goats , Oxidation-Reduction
10.
Anim Sci J ; 87(6): 816-26, 2016 Jun.
Article in English | MEDLINE | ID: mdl-26890722

ABSTRACT

Examined was the effect of post mortem refrigerated storage on microbial spoilage, lipid-protein oxidation and physicochemical traits of goat meat. Seven Boer bucks were slaughtered, eviscerated and aged for 24 h. The Longissimus lumborum (LL) and Semitendinosus (ST) muscles were excised and subjected to 13 days post mortem refrigerated storage. The pH, lipid and protein oxidation, tenderness, color and drip loss were determined in LL while microbiological analysis was performed on ST. Bacterial counts generally increased with increasing aging time and the limit for fresh meat was reached at day 14 post mortem. Significant differences were observed in malondialdehyde (MDA) content at day 7 of storage. The thiol concentration significantly reduced as aging time increased. The band intensities of myosin heavy chain (MHC) and troponin-T significantly decreased as storage progressed, while actin remained relatively stable. After 14 days of aging, tenderness showed significant improvement while muscle pH and drip loss reduced with increase in storage time. Samples aged for 14 days had higher lightness (P < 0.05) and lower (P < 0.05) yellowness and redness. Post mortem refrigerated storage influenced oxidative and microbial stability and physico-chemical properties of goat meat.


Subject(s)
Chemical Phenomena , Fats/analysis , Food Analysis , Food Microbiology , Food Preservation , Food Storage , Goats , Lipid Metabolism , Meat/analysis , Meat/microbiology , Oxidation-Reduction , Postmortem Changes , Proteins/analysis , Proteins/metabolism , Refrigeration , Animals , Food Safety , Male
11.
Anim Sci J ; 86(12): 981-91, 2015 Dec.
Article in English | MEDLINE | ID: mdl-26208249

ABSTRACT

This study assessed the effect of halal slaughter and anesthesia pre-slaughter followed by bleeding on meat quality characteristics of goats. Eleven male Boer cross goats were divided into two groups and subjected to either halal slaughter (HS) or anesthesia with halothane and propofol pre-slaughter (AS). At pre-rigor, HS had significantly lower (P < 0.05) muscle pH and glycogen than AS. However, no significant difference was observed in the pH and glycogen content between the treatments on 1, 3 and 7 days post mortem. The drip loss of HS was significantly lower (P < 0.05) than that of AS at all aging periods. Treatment had no effect on sarcomere length, myofibrillar fragmentation index and shear force values, loss of thiol groups and degradation of major myofibrillar proteins. It can be concluded that HS did not have deleterious effect on meat quality traits of goat when compared to AS.


Subject(s)
Chemical Phenomena , Food Quality , Goats/metabolism , Halothane/pharmacology , Meat , Muscle, Skeletal/metabolism , Abattoirs , Anesthesia , Animals , Glycogen/metabolism , Hydrogen-Ion Concentration , Male , Muscle Proteins/metabolism , Muscle, Skeletal/drug effects , Myofibrils/metabolism , Postmortem Changes , Propofol , Sarcomeres , Shear Strength , Sulfhydryl Compounds/metabolism , Time Factors