Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters











Database
Language
Publication year range
1.
Rev Sci Instrum ; 95(8)2024 Aug 01.
Article in English | MEDLINE | ID: mdl-39177463

ABSTRACT

We introduce a novel piezoelectric stepper motor featuring high compactness, rigidity, and any direction operability. Here, not only is the structure of high novelty but also the working principle very simple. The piezo stacks unit is sandwiched between two spring finger pieces, with almost equal clamping forces applied between the top of the piezo stacks' unit and the spring finger piece. Applying individual driving signals to each of the five piezo stack pairs, causing deformation one by one in the same direction, followed by simultaneous recovery in the reverse direction, enables movement of the frame part. The optimized clamping force of the piezoelectric stack units and spring fingers ensures maximum output force. The motor's operational capability at low threshold voltages, specifically 8 V for downward movement and 10 V for upward movement, confirmed its efficacy in both vertical and horizontal directions. The motor's operational capability at a low threshold voltage of 10 V confirmed its efficacy in both vertical and horizontal directions. At room temperature, step size ranges from 0.3 to 7.4 µm at 20 Hz frequency and varying driving voltage from 10 to 180 V. It has a maximum travel range of about 5 mm and can lift a maximum load of 220 g in an upward direction, so the maximum output force generated by this motor is 2.2 N. The compact and rigid design is capable of building an atomically resolved scanning probe microscope, and its working ability has the potential to use the cleavage of different types of samples in limited space environments, such as the small-bore superconducting magnet and low temperature.

2.
Micromachines (Basel) ; 13(11)2022 Nov 07.
Article in English | MEDLINE | ID: mdl-36363942

ABSTRACT

Magnetic Force Microscopy (MFM) is among the best techniques for examining and assessing local magnetic characteristics in surface structures at scales and sizes. It may be viewed as a unique way to operate atomic force microscopy with a ferromagnetic tip. The enhancement of magnetic signal resolution, the utilization of external fields during measurement, and quantitative data analysis are now the main areas of MFM development. We describe a new structure of MFM design based on a cryogen-free superconducting magnet. The piezoelectric tube (PZT) was implemented with a tip-sample coarse approach called SpiderDrive. The technique uses a magnetic tip on the free end of a piezo-resistive cantilever which oscillates at its resonant frequency. We obtained a high-quality image structure of the magnetic domain of commercial videotape under extreme conditions at 5 K, and a high magnetic field up to 11 T. When such a magnetic field was gradually increased, the domain structure of the videotape did not change much, allowing us to maintain the images in the specific regions to exhibit the performance. In addition, it enabled us to locate the sample region in the order of several hundred nanometers. This system has an extensive range of applications in the exploration of anisotropic magnetic phenomena in topological materials and superconductors.

3.
Materials (Basel) ; 13(11)2020 Jun 10.
Article in English | MEDLINE | ID: mdl-32531988

ABSTRACT

The objectives of this study were to reduce the corrosion rate and increase the cytocompatibility of AZ31 Mg alloy. Two coatings were considered. One coating contained MgO (MAO/AZ31). The other coating contained Cu2+ (Cu/MAO/AZ31), and it was produced on the AZ31 Mg alloy via microarc oxidation (MAO). Coating characterization was conducted using a set of methods, including scanning electron microscopy, energy-dispersive spectrometry, X-ray photoelectron spectroscopy, and X-ray diffraction. Corrosion properties were investigated through an electrochemical test, and a H2 evolution measurement. The AZ31 Mg alloy with the Cu2+-containing coating showed an improved and more stable corrosion resistance compared with the MgO-containing coating and AZ31 Mg alloy specimen. Cell morphology observation and cytotoxicity test via Cell Counting Kit-8 assay showed that the Cu2+-containing coating enhanced the proliferation of L-929 cells and did not induce a toxic effect, thus resulting in excellent cytocompatibility and biological activity. In summary, adding Cu ions to MAO coating improved the corrosion resistance and cytocompatibility of the coating.

SELECTION OF CITATIONS
SEARCH DETAIL