Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 163
Filter
1.
Am J Cardiol ; 220: 49-55, 2024 Apr 04.
Article in English | MEDLINE | ID: mdl-38580038

ABSTRACT

On July 31, 2023, the Trifecta valve was withdrawn from the market after concerns regarding early (≤5 years) structural valve deterioration (SVD), mainly as aortic regurgitation (AR). Our aim was to determine the timing, mechanism, and impact of bioprosthetic SVD in patients who underwent redo aortic valve replacement (redo-AVR) with either redo-SAVR or valve-in-valve transcatheter aortic valve replacement (TAVR) using Trifecta versus other bioprosthetic valves. Patients who underwent redo-AVR for SVD at our institution were categorized into 2 groups based on the valve type: Trifecta versus non-Trifecta. Multivariate Cox proportional hazard model and Kaplan-Meier curves were used to compare mortality. A total of 171 patients were included; 58 (34%) had previous SAVR with a Trifecta valve and 113 (66%) with non-Trifecta valve. A total of 103 patients (60%) underwent valve-in-valve TAVR and 68 redo-SAVR (40%). The age, gender, and Society of Thoracic Surgeons score were similar between Trifecta and non-Trifecta groups. In patients with bioprosthetic valves requiring redo-AVR, Trifecta valves had an earlier onset of greater than moderate AR (4.5 vs 11.9 years, p <0.001) and earlier time to redo-AVR (5.5 vs 12 years, p <0.001). AR was more common as the mechanism of SVD in Trifecta versus non-Trifecta valves (55.2% vs 30.1%, p = 0.006). All-cause adjusted mortality from index SAVR was higher in the Trifecta than in non-Trifecta group (hazard ratio 4.1, 95% confidence interval 1.5 to 11.5, p = 0.007). In conclusion, compared with non-Trifecta valves, Trifecta valves exhibit early SVD primarily as AR and progress rapidly to significant SVD requiring redo-AVR. Mortality is significantly higher with Trifecta than in non-Trifecta valves, potentially impacting the results of SAVR versus TAVR studies.

2.
J Gastrointest Surg ; 2024 Apr 02.
Article in English | MEDLINE | ID: mdl-38574963

ABSTRACT

BACKGROUND: Morbidity for liver resection has decreased, and frail patients are undergoing surgery. The effect of minimally invasive liver resection (MILR) is unknown. This study aimed to evaluate the effect of MILR on the outcomes in frail patients. METHODS: Elective hepatectomies from the 2014-2020 American College of Surgeons National Surgical Quality Improvement Program hepatectomy-specific Participant User File were reviewed. The 5-factor modified frailty index (mFI-5) was used. It includes diabetes mellitus, hypertension, functional status, heart failure, and dyspnea. Patients were considered frail if their mFI-5 score was ≥2. RESULTS: A total of 3116 patients were included: 2117 (67.9%) in the minor hepatectomy group and 999 (32%) in the major hepatectomy group. There were 2254 open cases and 862 MILRs. Postoperatively, patients in the minor hepatectomy group who underwent MILR had lower rates of prolonged length of stay (LOS), nonhome discharge, transfusion, major complications, and minor complications (P < .05). Postoperatively, patients in the major hepatectomy group who underwent MILR had lower rates of prolonged LOS and any complication (P < .05). In the minor hepatectomy group, MILR remained independently predictive of lower rates of prolonged LOS (odds ratio [OR], 0.34; 95% CI, 0.28-0.42), nonhome discharge (OR, 0.58; 95% CI, 0.41-0.84), transfusion (OR, 0.72; 95% CI, 0.54-0.96), major complication (OR, 0.78; 95% CI, 0.62-1.00), and any complication (OR, 0.73; 95% CI, 0.58-0.92). In the major hepatectomy group, MILR remained independently predictive of prolonged LOS (OR, 0.60; 95% CI, 0.40-0.89). CONCLUSION: MILR resulted in lower rates of complications in the minor hepatectomy group and shorter LOS in the major hepatectomy group. The minimally invasive approach to hepatectomy may benefit frail patients with cancer.

3.
JACC Cardiovasc Interv ; 17(8): 1032-1044, 2024 Apr 22.
Article in English | MEDLINE | ID: mdl-38456883

ABSTRACT

BACKGROUND: The fifth-generation SAPIEN 3 Ultra Resilia valve (S3UR) incorporates several design changes as compared with its predecessors, the SAPIEN 3 (S3) and SAPIEN 3 Ultra (S3U) valves, including bovine leaflets treated with a novel process intended to reduce structural valve deterioration via calcification, as well as a taller external skirt on the 29-mm valve size to reduce paravalvular leak (PVL). The clinical performance of S3UR compared with S3 and S3U in a large patient population has not been previously reported. OBJECTIVES: The aim of this study was to compare S3UR to S3/S3U for procedural, in-hospital, and 30-day clinical and echocardiographic outcomes after transcatheter aortic valve replacement (TAVR). METHODS: Patients enrolled in the STS/ACC TVT (Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy) Registry between January 1, 2021, and June 30, 2023, who underwent TAVR with S3UR or S3U/S3 valve platforms were propensity-matched and evaluated for procedural, in-hospital, and 30-day clinical and echocardiographic outcomes. RESULTS: 10,314 S3UR patients were propensity matched with 10,314 patients among 150,539 S3U/S3 patients. At 30 days, there were no statistically significant differences in death, stroke, or bleeding, but a numerically higher hospital readmission rate in the S3UR cohort (8.5% vs 7.7%; P = 0.04). At discharge, S3UR patients exhibited significantly lower mean gradients (9.2 ± 4.6 mm Hg vs 12.0 ± 5.7 mm Hg; P < 0.0001) and larger aortic valve area (2.1 ± 0.7 cm2 vs 1.9 ± 0.6 cm2; P < 0.0001) than patients treated with S3/S3U. The 29-mm valve size exhibited significant reduction in mild PVL (5.3% vs 9.4%; P < 0.0001). CONCLUSIONS: S3UR TAVR is associated with lower mean gradients and lower rates of PVL than earlier generations of balloon expandable transcatheter heart valve platforms.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Balloon Valvuloplasty , Heart Valve Prosthesis , Prosthesis Design , Recovery of Function , Registries , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Female , Humans , Male , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/physiopathology , Balloon Valvuloplasty/adverse effects , Hemodynamics , Postoperative Complications/etiology , Retrospective Studies , Risk Assessment , Risk Factors , Time Factors , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome , United States
4.
Surg Endosc ; 38(5): 2553-2561, 2024 May.
Article in English | MEDLINE | ID: mdl-38488870

ABSTRACT

BACKGROUND: Minimally invasive surgery provides an unprecedented opportunity to review video for assessing surgical performance. Surgical video analysis is time-consuming and expensive. Deep learning provides an alternative for analysis. Robotic pancreaticoduodenectomy (RPD) is a complex and morbid operation. Surgeon technical performance of pancreaticojejunostomy (PJ) has been associated with postoperative pancreatic fistula. In this work, we aimed to utilize deep learning to automatically segment PJ RPD videos. METHODS: This was a retrospective review of prospectively collected videos from 2011 to 2022 that were in libraries at tertiary referral centers, including 111 PJ videos. Each frame of a robotic PJ video was categorized based on 6 tasks. A 3D convolutional neural network was trained for frame-level visual feature extraction and classification. All the videos were manually annotated for the start and end of each task. RESULTS: Of the 100 videos assessed, 60 videos were used for the training the model, 10 for hyperparameter optimization, and 30 for the testing of performance. All the frames were extracted (6 frames/second) and annotated. The accuracy and mean per-class F1 scores were 88.01% and 85.34% for tasks. CONCLUSION: The deep learning model performed well for automated segmentation of PJ videos. Future work will focus on skills assessment and outcome prediction.


Subject(s)
Deep Learning , Pancreaticojejunostomy , Robotic Surgical Procedures , Humans , Robotic Surgical Procedures/methods , Pancreaticojejunostomy/methods , Retrospective Studies , Pancreaticoduodenectomy/methods , Video Recording
5.
Surgery ; 175(4): 1168-1175, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38307784

ABSTRACT

BACKGROUND: Within the past decade, minimally invasive pancreaticoduodenectomy has been increasingly adopted in high-volume cancer centers. Amid broader trends of a growing older population, the numbers of frail patients with cancer are expected to increase. In this study, we compared the postoperative outcomes of open pancreaticoduodenectomy and minimally invasive pancreaticoduodenectomy in frail patients with pancreatic ductal adenocarcinoma. METHODS: Using the pancreatectomy-targeted American College of Surgeons-National Surgical Quality Improvement Program database (2014-2021), we identified pancreaticoduodenectomy cases for pancreatic ductal adenocarcinoma. Patients with a modified frailty index ≥2 were considered frail. We performed 2:1 (open pancreaticoduodenectomy to minimally invasive pancreaticoduodenectomy) optimal pair propensity score matching for both patient- and disease-specific characteristics. We evaluated baseline covariate balance for homogeneity and assessed 30-day postoperative outcomes: complications, discharge destination, major morbidity, and mortality. RESULTS: We identified 3,143 frail patients who underwent pancreaticoduodenectomy for pancreatic ductal adenocarcinoma. Of those, 275 (9%) underwent minimally invasive pancreaticoduodenectomy. Minimally invasive pancreaticoduodenectomy was associated with a lower rate of any complications compared with open pancreaticoduodenectomy (43% vs 54%; P < .001), major morbidity (29% vs 35%; P = .042), and nonhome discharge (12% vs 17%; P = .022). When comparing the 2 minimally invasive pancreaticoduodenectomy approaches, robotic surgery was associated with fewer complications compared with laparoscopy (39% vs 51%; P = .040) and a lower mortality rate (1% vs 4%; P = .041) CONCLUSION: In frail patients with pancreatic cancer, minimally invasive pancreaticoduodenectomy was associated with better postoperative outcomes than open pancreaticoduodenectomy. This study builds on growing literature reporting that, when properly implemented, minimally invasive pancreaticoduodenectomy is associated with more favorable postoperative outcomes. Given the particularly high risk of complication in frail patients, implementing a preoperative frailty assessment can provide valuable insights to inform patient counseling.


Subject(s)
Carcinoma, Pancreatic Ductal , Frailty , Laparoscopy , Pancreatic Neoplasms , Robotic Surgical Procedures , Humans , Aged , Pancreaticoduodenectomy/adverse effects , Frailty/complications , Frail Elderly , Retrospective Studies , Carcinoma, Pancreatic Ductal/surgery , Robotic Surgical Procedures/adverse effects , Laparoscopy/adverse effects , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Postoperative Complications/surgery , Minimally Invasive Surgical Procedures/adverse effects
6.
Ann Thorac Surg ; 2024 Feb 03.
Article in English | MEDLINE | ID: mdl-38316377

ABSTRACT

BACKGROUND: Our objective was to compare the impact of patient-prosthesis mismatch (PPM) for 2 years after surgical aortic valve replacement within the prospective, randomized Placement of Aortic Transcatheter Valves (PARTNER) trials. METHODS: Surgical aortic valve replacement patients from the PARTNER 1, 2, and 3 trials were included. PPM was classified as moderate (indexed effective orifice area ≤0.85 cm2/m2) or severe (indexed effective orifice area ≤0.65 cm2/m2). The primary endpoint was the composite of all-cause death and heart failure rehospitalization at 2 years. RESULTS: By the predicted PPM method (PPMP), 59.1% had no PPM, 38.8% moderate PPM, and 2.1% severe PPM; whereas by the measured PPM method (PPMM), 42.4% had no PPM, 36.0% moderate, and 21.6% severe. Patients with no PPMP (23.6%) had a lower rate of the primary endpoint compared with patients with moderate (28.2%, P = .03) or severe PPMP (38.8%, P = .02). Using the PPMM method, there was no difference between the no (17.7%) and moderate PPMM groups (21.1%) in the primary outcome (P = .16). However, those with no PPMM or moderate PPMM were improved compared with severe PPMM (27.4%, P < .001 and P = .02, respectively). CONCLUSIONS: Severe PPM analyzed by PPMP was only 2.1% for surgical aortic valve replacement patients. The PPMM method overestimated the incidence of severe PPM relative to PPMP, but was also associated with worse outcome. There was higher all-cause mortality in patients with severe PPM, thus surgical techniques to minimize PPM remain critical.

7.
Int. j. morphol ; 42(1): 205-215, feb. 2024. ilus, tab
Article in English | LILACS | ID: biblio-1528814

ABSTRACT

SUMMARY: This study assessed the effects of Acacia Senegal (AS) combined with insulin on Na+/K+-ATPase (NKA) activity and mRNA expression, serum glucose, renal function, and oxidative stress in a rat model of diabetic nephropathy (DN). Sixty rats were equally divided into six groups: normal control, normal+AS, diabetic (DM), DM+insulin, DM+AS, and DM+insulin+AS groups. Diabetes mellitus (type 1) was induced by a single injection of streptozotocin (65 mg/kg), and insulin and AS treatments were carried until rats were culled at the end of week 12. Serum glucose and creatinine levels, hemoglobin A1c (HbA1c) were measured. Renal homogenate levels of NKA activity and gene expression, malondialdehyde, superoxide dismutase (SOD), catalase and reduced glutathione (GSH) were evaluated as well as kidney tissue histology and ultrastructure. Diabetes caused glomerular damage and modulation of blood and tissue levels of creatinine, glucose, HbA1c, malondialdehyde, NKA activity and gene expression, SOD, catalase and GSH, which were significantly (p<0.05) treated with AS, insulin, and insulin plus AS. However, AS+insulin treatments were more effective. In conclusion, combined administration of AS with insulin to rats with DN decreased NKA activity and gene expression as well as oxidative stress, and improved glycemic state and renal structure and function.


Este estudio evaluó los efectos de Acacia senegal (AS) combinada con insulina sobre la actividad Na+/K+- ATPasa (NKA) y la expresión de ARNm, la glucosa sérica, la función renal y el estrés oxidativo en un modelo de nefropatía diabética (ND) en ratas. Sesenta ratas se dividieron equitativamente en seis grupos: control normal, normal+AS, diabética (DM), DM+insulina, DM+AS y DM+insulina+AS. La diabetes mellitus (tipo 1) se indujo mediante una única inyección de estreptozotocina (65 mg/kg), y los tratamientos con insulina y AS se llevaron a cabo hasta que las ratas fueron sacrificadas al final de la semana 12. Se midieron niveles séricos de glucosa y creatinina, hemoglobina A1c (HbA1c). Se evaluaron los niveles de homogeneizado renal de actividad NKA y expresión génica, malondialdehído, superóxido dismutasa (SOD), catalasa y glutatión reducido (GSH), así como la histología y ultraestructura del tejido renal. La diabetes causó daño glomerular y modulación de los niveles sanguíneos y tisulares de creatinina, glucosa, HbA1c, malondialdehído, actividad y expresión génica de NKA, SOD, catalasa y GSH, los cuales fueron tratados significativamente (p<0,05) con AS, insulina e insulina más AS. Sin embargo, los tratamientos con AS+insulina fueron más efectivos. En conclusión, la administración combinada de AS con insulina a ratas con DN disminuyó la actividad de NKA y la expresión genética, así como el estrés oxidativo, y mejoró el estado glucémico y la estructura y función renal.


Subject(s)
Animals , Male , Rats , Plant Extracts/administration & dosage , Sodium-Potassium-Exchanging ATPase/drug effects , Diabetic Nephropathies/drug therapy , Acacia/chemistry , Superoxide Dismutase , Glycated Hemoglobin/analysis , Plant Extracts/pharmacology , Gene Expression , Rats, Sprague-Dawley , Sodium-Potassium-Exchanging ATPase/genetics , Oxidative Stress , Microscopy, Electron, Transmission , Disease Models, Animal , Drug Therapy, Combination , Glycemic Control , Insulin/administration & dosage , Kidney/drug effects , Malondialdehyde
8.
Updates Surg ; 76(2): 555-563, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37847484

ABSTRACT

The current literature is poor with studies handling the role of laparoscopy in managing diaphragmatic eventration (DE). Herein, we describe our experience regarding the role of laparoscopy in managing DE patients presenting mainly with gastrointestinal symptoms. We retrospectively reviewed the data of 20 patients who underwent laparoscopic diaphragmatic plication between January 2010 and December 2018. Postoperative outcomes and quality of life were assessed. Most DEs were left sided (95%). Laparoscopic diaphragmatic plication was possible in all patients, along with correcting all associated gastrointestinal and diaphragmatic problems. The former included gastric volvulus (60%), reflux esophagitis (25%), cholelithiasis (5%), and pyloric obstruction (5%), while the latter included diaphragmatic and hiatus hernia (10% and 15%, respectively).The average operative time was 142 min. All patients had a regular (reviewer #1) postoperative course except for one who developed hydro-pneumothorax. At a median follow-up of 48 months, midterm outcomes were satisfactory, with an improvement (reviewer #1) in gastrointestinal symptoms. Three patients (reviewer #1) developed radiological recurrence without significant clinical symptoms. Patient's quality of life, including all parameters, significantly improved after the laparoscopic procedure compared to the preoperative values. Laparoscopic approach is safe and effective for managing adult diaphragmatic eventration (reviewer #1).


Subject(s)
Diaphragmatic Eventration , Laparoscopy , Humans , Diaphragmatic Eventration/surgery , Diaphragmatic Eventration/complications , Retrospective Studies , Quality of Life , Diaphragm/surgery , Laparoscopy/methods
9.
Am J Cardiol ; 213: 140-145, 2024 Feb 15.
Article in English | MEDLINE | ID: mdl-38134979

ABSTRACT

Transcatheter aortic valve replacement (TAVR) has emerged as a successful treatment option for severe aortic stenosis. However, the long-term outcomes of TAVR in nonagenarians is lacking. We aimed to examine the long-term mortality and quality of life in nonagenarians after TAVR. This is a multicenter, retrospective analysis on patients with severe aortic stenosis who underwent TAVR. Patients were divided into 2 groups: nonagenarians (age ≥90 years) and age <90 years. The Kansas City cardiomyopathy questionnaire (KCCQ) and New York Heart Association (NYHA) scores were compared before and after TAVR. All-cause mortality was compared between both groups at 30 days, 1 year, and 5 years after TAVR using the Cox proportional hazard model. A total of 6,896 patients were included, of whom 591 were nonagenarians. Nonagenarians had a higher Society of Thoracic Surgeons perioperative risk of mortality (8.1 ± 4.6% vs 5.4 ± 4.2%, p <0.001) before TAVR. Both groups were similar in KCCQ and NYHA scores at baseline. At 1 year after TAVR, there was no significant difference in improvement in the KCCQ overall score between those aged <90 years and nonagenarians (-4.76, 95% confidence interval [CI] -11.4 to 1.9, p = 0.161). Similarly, there was no statistically significant difference in improvement in NYHA class between the 2 groups at 1 year (odds ratio 1.07, 95% CI 0.85 to 1.25), p = 0.526). The unadjusted 30-day (3.2% vs 2.7%, hazard ratio 1.11, 95% CI 0.70 to 1.80, p = 0.667) and 5-year (28.0% vs 26.6%, hazard ratio 1.05, 95% CI 0.89 to 1.24, p = 0.60) all-cause mortality were similar between the 2 groups. In conclusion, this study demonstrates an excellent long-term mortality rate at 5 years after TAVR in nonagenarians, comparable to patients younger than 90 years. There is a significant and enduring improvement in functional status in nonagenarians, observed up to 1 year after TAVR.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Aged, 80 and over , Humans , Quality of Life , Nonagenarians , Treatment Outcome , Retrospective Studies , Aortic Valve/surgery , Risk Factors
10.
JACC Cardiovasc Interv ; 16(24): 2999-3012, 2023 Dec 25.
Article in English | MEDLINE | ID: mdl-37902146

ABSTRACT

BACKGROUND: Data comparing valve systems in the valve-in-valve transcatheter aortic valve replacement (ViV-TAVR) field have been obtained from retrospective studies. OBJECTIVES: The authors sought to compare the 1-year hemodynamic performance and clinical outcomes between balloon-expandable valves (BEV) SAPIEN 3/ULTRA (Edwards Lifesciences) and self-expanding valves (SEV) Evolut R/PRO/PRO+ (Medtronic) in ViV-TAVR. METHODS: Patients with a failed small (≤23 mm) surgical valve undergoing ViV-TAVR were randomized to receive a SEV or a BEV. Patients had a clinical and valve hemodynamic (Doppler echocardiography) evaluation at 1-year follow-up. Study outcomes were defined according to VARC-2/VARC-3 criteria. Intended performance of the valve was defined as mean gradient <20 mm Hg, peak velocity <3 m/s, Doppler velocity index ≥0.25 and less than moderate AR. RESULTS: A total of 98 patients underwent ViV-TAVR (46 BEV, 52 SEV). At 1-year follow-up, patients receiving a SEV had a lower mean transaortic gradient (22 ± 8 mm Hg BEV vs 14 ± 7 mm Hg SEV; P < 0.001), and a higher rate of intended valve performance (BEV: 30%, SEV:76%; P < 0.001). There were no cases of greater than mild aortic regurgitation. There were no differences in functional status (NYHA functional class >II, BEV: 7.3%, SEV: 4.1%; P = 0.505) or quality of life (Kansas City Cardiomyopathy Questionnaire, BEV: 77.9 ± 21.2, SEV: 81.8 ± 14.8; P = 0.334). No differences in all-cause mortality (BEV: 6.5%, SEV: 3.8; P = 0.495), heart failure hospitalization (BEV: 6.5%, SEV: 1.9%; P = 0.214), stroke (BEV: 0%, SEV: 1.9%; P = 0.369), myocardial infarction (BEV: 0%, SEV: 1.9%; P = 0.347), or pacemaker implantation (BEV: 2.2%, SEV: 1.9%; P = 0.898) were found. CONCLUSIONS: In patients who underwent ViV-TAVR for failed small aortic bioprostheses, those receiving a SEV exhibited a better valve hemodynamic profile at 1-year follow-up. There were no differences between SEV and BEV regarding functional status, quality of life, or clinical outcomes.


Subject(s)
Aortic Valve Stenosis , Bioprosthesis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Retrospective Studies , Quality of Life , Treatment Outcome , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Prosthesis Design
11.
J Gastrointest Surg ; 27(12): 2823-2842, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37903972

ABSTRACT

BACKGROUND: There is an increasing use of neoadjuvant treatment (NAT) for pancreatic cancer (PC) followed by minimally invasive pancreatoduodenectomy (MIPD). We evaluate the impact of the surgical approach on 30-day outcomes in PC patients who underwent NAT. METHODS: Patients with PC who had NAT followed by MIPD or open pancreatoduodenectomy (OPD) were identified from a pancreatectomy-targeted dataset (2014-2020) of the National Surgical Quality Improvement Program. Comparisons were made between MIPD and OPD within NAT groups. RESULTS: A total of 5588 patients were analyzed. Of those, 4907 underwent OPD and 476 underwent MIPD. In addition, 3559 patients received neoadjuvant chemotherapy alone and 1830 received neoadjuvant chemoradiation. In the chemotherapy-alone group, the MIPD subgroup had lower rates of any complication (38.2% vs. 45.8%, P = 0.005), but there were no differences in mortality (2.1% for MIPD vs 1.9% for OPD, P=0.8) or serious complication (11.8% for MIPD vs 15% for OPD, P=0.1). On multivariable analysis, MIPD was independently predictive of lower rates of any complication (OR: 0.74, 95% CI 0.6-0.93, P = 0.0009), CR-POPF (OR: 0.58, 95% CI 0.35-0.96, P = 0.04), and shorter LOS (estimate: -1.03, 95% CI -1.73 to -0.32, P = 0.004). In the chemoradiation group, patients undergoing MIPD had higher rates of preoperative diabetes (P < 0.05), but there were no significant differences in any outcomes between the two approaches in this group. CONCLUSION: MIPD is safe and feasible after NAT. Patients having neoadjuvant chemotherapy alone followed by MIPD had lower rates of complications, shorter LOS, and fewer CR-POPFs compared to OPD.


Subject(s)
Laparoscopy , Pancreatic Neoplasms , Humans , Pancreaticoduodenectomy/adverse effects , Neoadjuvant Therapy , Pancreatic Neoplasms/surgery , Minimally Invasive Surgical Procedures/adverse effects , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Postoperative Complications/surgery , Retrospective Studies
12.
Am J Cardiol ; 205: 1-9, 2023 10 15.
Article in English | MEDLINE | ID: mdl-37573632

ABSTRACT

Transcatheter aortic valve replacement (TAVR) carries a risk of high-grade AV block requiring cardiac implantable electronic device (CIED) implantation, which has been associated with a higher mortality rate. However, the outcomes of TAVR in patients with preexisting CIEDs are not well understood. We conducted a retrospective analysis of consecutive patients who underwent TAVR from December 2014 to December 2019 at our institution. Patients were categorized into 3 groups: preexisting CIED pre-TAVR (group 1), CIED implanted within 30 days after TAVR (group 2), and no CIED implanted (group 3). Cox proportional hazard was conducted to determine the primary end point of all-cause mortality. A total of 366 patients were included, of whom 93 (25.4%), 51 (13.9%), and 222 (60.7%) comprised group 1, 2, and 3, respectively. The median follow-up time was 2.3 years. The all-cause mortality rate was higher in group 1 than group 2 (hazard ratio [HR] 2.60, 95% confidence interval [CI] 1.09 to 6.18, p = 0.03) and group 3 (HR 1.96, 95% CI 1.24 to 3.08, p = 0.004). On the multivariate analysis, there was no statistically significant difference in mortality among the groups (group 1 vs group 2: HR 1.95, 95% CI 0.70 to 5.44, p = 0.20 and group 1 vs group 3: HR 1.27, 95% CI 0.66 to 2.43, p = 0.47). Preoperative hemoglobin ≤12 g/100 ml was an independent predictor of all-cause mortality (HR 1.75, 95% CI 1.10 to 2.80, p = 0.02). Group 1 had a higher 1 year congestive heart failure readmission rate (29%) than group 2 (17.6%) and group 3 (8.1%; p <0.0001). In conclusion, there was no difference in the adjusted long-term survival based on the CIED grouping. However, patients with preexisting CIEDs had higher all-cause mortality and 1-year congestive heart failure readmission rates owing to their higher co-morbidity burden, irrespective of their Society of Thoracic Surgeons score. This can be taken into account for preoperative risk stratification.


Subject(s)
Aortic Valve Stenosis , Heart Failure , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve Stenosis/complications , Retrospective Studies , Treatment Outcome , Risk Factors , Heart Failure/complications , Aortic Valve/surgery
13.
Surg Endosc ; 37(10): 7667-7675, 2023 10.
Article in English | MEDLINE | ID: mdl-37517041

ABSTRACT

BACKGROUND: Many surgeons believe that pre-operative balloon dilatation makes laparoscopic myotomy more difficult in achalasia patients. Herein, we wanted to see if prior pneumatic balloon dilatation led to worse outcomes after laparoscopic myotomy. We also assessed if the frequency of dilatations and the time interval between the last one and the surgical myotomy could affect these outcomes. METHODS: The data of 460 patients was reviewed. They were divided into two groups: the balloon dilation (BD) group (102 patients) and the non-balloon dilatation (non-BD) group (358 patients). RESULTS: Although pre-operative parameters and surgical experience were comparable between the two groups, the incidence of mucosal perforation, operative time, and intraoperative blood loss significantly increased in the BD group. The same group also showed a significant delay in oral intake and an increased hospitalization period. At a median follow-up of 4 years, the incidence of post-operative reflux increased in the BD group, while patient satisfaction decreased. Patients with multiple previous dilatations showed a significant increase in operative time, blood loss, perforation incidence, hospitalization period, delayed oral intake, and reflux esophogitis compared to single-dilatation patients. When compared to long-interval cases, patients with short intervals had a higher incidence of mucosal perforation and a longer hospitalization period. CONCLUSION: Pre-operative balloon dilatation has a significant negative impact on laparoscopic myotomy short and long term outcomes. It is associated with a significant increase in operative time, blood loss, mucosal injury, hospitalization period, and incidence of reflux symptoms. More poor outcomes are encountered in patients with multiple previous dilatations and who have a short time interval between the last dilatation and the myotomy.


Subject(s)
Esophageal Achalasia , Gastroesophageal Reflux , Heller Myotomy , Laparoscopy , Humans , Esophageal Achalasia/surgery , Dilatation , Heller Myotomy/adverse effects , Laparoscopy/adverse effects , Gastroesophageal Reflux/surgery , Treatment Outcome
14.
J Am Soc Echocardiogr ; 36(12): 1302-1314, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37507058

ABSTRACT

BACKGROUND: The role of echocardiography in deriving transvalvular mean gradients from transaortic velocities in aortic stenosis (AS) and in structural valve degeneration (SVD) is well established. However, reports following surgical aortic valve replacement, post-transcatheter aortic valve replacement (TAVR), and valve-in-valve-TAVR (ViV-TAVR) have cautioned against the use of echocardiography-derived mean gradients to assess normal functioning bioprosthesis due to discrepancy compared with invasive measures in a phenomenon called discordance. METHODS: In a multicenter study, intraprocedural echocardiographic and invasive mean gradients in AS, SVD, post-native TAVR, and post-ViV-TAVR were compared, when obtained concomitantly, and discharge echocardiographic gradients were recorded. Absolute discordance (intraprocedural echocardiographic - invasive mean gradient) and percent discordance (intraprocedural echocardiographic - invasive mean gradient/echocardiographic mean gradient) were calculated. Multivariable regression analysis was performed to determine variables independently associated with elevated postprocedure invasive gradients ≥20 mm Hg, absolute discordance >10 mm Hg, and discharge echocardiographic mean gradient ≥20 mm Hg. RESULTS: A total of 5,027 patients were included in the registry: 4,725 native TAVR and 302 ViV-TAVR. Intraprocedural concomitant echocardiographic and invasive mean gradients were obtained pre-TAVR in AS (n = 2,418), pre-ViV-TAVR in SVD (n = 101), in post-ViV-TAVR (n = 77), and in post-TAVR (n = 823). Echocardiographic and invasive mean gradients demonstrated strong correlation (r = 0.69) and agreement (bias, 0.11; 95% CI, -0.4-0.62) in AS, moderate correlation (r = 0.56) and agreement (bias, 1.08; 95% CI, -2.53 to 4.59) in SVD, moderate correlation (r = 0.61) and weak agreement (bias, 6.47; 95% CI, 5.08-7.85) post-ViV-TAVR, and weak correlation (r = 0.18) and agreement (bias, 3.41; 95% CI, 3.16-3.65) post-TAVR. Absolute discordance occurs primarily in ViV-TVR and is not explained by sinotubular junction size and increases with increasing echocardiographic mean gradient. Percent discordance in AS and SVD (1.3% and 4%, respectively) was lower compared with post-TAVR/ViV-TAVR (66.7% and 100%, respectively). Compared with self-expanding valves, balloon expanding valves were independently associated with elevated discharge echocardiographic but lower invasive mean gradient (odds ratio = 3.411, 95% CI, 1.482-7.852, P = .004; vs odds ratio = 0.308, 95% CI, 0.130-0.731, P = .008, respectively). CONCLUSIONS: Post-TAVR/ViV-TAVR, echocardiography is discordant from invasive mean gradients, and absolute discordance increases with increasing echocardiographic mean gradient and is not explained by sinotubular junction size. Percent discordance is significantly higher post-TAVR/ViV-TAVR than in AS and SVD. Post-TAVR/ViV-TAVR, poor correlation and wide limits of agreement suggest echocardiographic and invasive mean gradients may not be used interchangeably and a high residual echocardiographic mean gradient should be confirmed invasively before considering any additional procedure to "correct" the gradient. Transcatheter aortic valve replacement valve types have variable impact on echocardiographic and invasive mean gradients.


Subject(s)
Aortic Valve Stenosis , Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Prosthesis Design , Prosthesis Failure , Treatment Outcome , Transcatheter Aortic Valve Replacement/methods , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/surgery , Echocardiography
15.
Langenbecks Arch Surg ; 408(1): 273, 2023 Jul 11.
Article in English | MEDLINE | ID: mdl-37430153

ABSTRACT

BACKGROUND: Biliary cystic neoplasms (BCNs) of the liver are rare pathologies encountered in hepatobiliary surgeries. Till now, there is a lack of definitive criteria used to differentiate biliary cystadenoma (BCA) from biliary cystadenocarcinoma (BCAC). METHODS: In the period between 2005 and 2018, the data of consecutive patients diagnosed with BCA and BCAC were retrospectively reviewed. RESULTS: A total of 62 patients underwent surgical management for BCNs. BCA was diagnosed in 50 patients while 12 patients had BCAC. Old age, male gender, smoking, and abdominal pain were strongly associated with BCAC. Left lobe location, small size, with the presence of mural nodule, and solid component were significantly noticed with BCAC. A novel pre-operative score was developed to predict the susceptibility for BCAC and help us to identify the optimal surgical strategy. Blood loss, operative time, and complications were comparable between the two study groups. CONCLUSION: Mural nodules or solid components are suggestive of BCAC. Complete surgical resection of cystic tumors of the liver is mandatory due to malignant potential of the lesion and for prolonged survival.


Subject(s)
Bile Duct Neoplasms , Cholangiocarcinoma , Liver Neoplasms , Neoplasms, Cystic, Mucinous, and Serous , Humans , Male , Retrospective Studies , Bile Ducts, Intrahepatic , Liver Neoplasms/surgery
17.
Surg Today ; 53(11): 1225-1235, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37052709

ABSTRACT

PURPOSE: To investigate the risk factors and outcomes of mucosal perforation (MP) during laparoscopic Heller myotomy (LHM) in patients with achalasia. METHODS: We conducted a retrospective analysis of patients who underwent LHM for achalasia at a single facility. RESULTS: Among 412 patients who underwent LHM for achalasia, MP was identified in 52 (12.6%). Old age, long disease duration, low albumin level, an esophageal transverse diameter > 6 cm, and a sigmoid-shaped esophagus were found to be independent predictors of MP. These factors were assigned a pre-operative score to predict the perforation risk. MP had a significant impact on intra and post-operative outcomes. Gastric side perforation was associated with a higher incidence of reflux symptoms, whereas esophageal-side perforation had a higher incidence of residual dysphagia. CONCLUSIONS: Many risk factors for MP have been identified. Correctable parameters like low serum albumin should be resolved prior to surgery, while uncorrectable parameters like old age and a sigmoid-shaped esophagus should be managed by experienced surgeons in high-volume centers. Implementing these recommendations will help decrease the incidence and consequences of this serious complication.


Subject(s)
Esophageal Achalasia , Heller Myotomy , Laparoscopy , Humans , Esophageal Achalasia/surgery , Retrospective Studies , Laparoscopy/adverse effects , Treatment Outcome , Risk Factors
18.
HPB (Oxford) ; 25(5): 577-588, 2023 05.
Article in English | MEDLINE | ID: mdl-36868951

ABSTRACT

BACKGROUND: Minimally invasive techniques are growing for hepatectomies. Laparoscopic and robotic liver resections have been shown to differ in conversions. We hypothesize that robotic approach will have decreased conversion to open and complications despite being a newer technique than laparoscopy. METHODS: ACS NSQIP study using the targeted Liver PUF from 2014 to 2020. Patients grouped based on hepatectomy type and approach. Multivariable and propensity scored matching (PSM) was used to analyze the groups. RESULTS: Of 7767 patients who underwent hepatectomy, 6834 were laparoscopic and 933 were robotic. The rate of conversions was significantly lower in robotic vs laparoscopic (7.8% vs 14.7%; p < 0.001). Robotic hepatectomy was associated with decreased conversion for minor (6.2% vs 13.1%; p < 0.001), but not major, right, or left hepatectomy. Operative factors associated with conversion included Pringle (OR = 2.09 [95% CI 1.05-4.19]; p = 0.0369), and a laparoscopic approach (OR = 1.96 [95% CI 1.53-2.52]; p < 0.001). Undergoing conversion was associated with increases in bile leak (13.7% vs 4.9%; p < 0.001), readmission (11.5% vs 6.1%; p < 0.001), mortality (2.1% vs 0.6%; p < 0.001), length of stay (5 days vs 3 days; p < 0.001), and surgical (30.5% vs 10.1%; p < 0.001), wound (4.9% vs 1.5%; p < 0.001) and medical (17.5% vs 6.7%; p < 0.001) complications. CONCLUSION: Minimally invasive hepatectomy with conversion is associated with increased complications, and conversion is increased in the laparoscopic compared to a robotic approach.


Subject(s)
Laparoscopy , Liver Neoplasms , Robotic Surgical Procedures , Humans , Hepatectomy/adverse effects , Hepatectomy/methods , Robotic Surgical Procedures/adverse effects , Risk Factors , Laparoscopy/adverse effects , Laparoscopy/methods , Postoperative Complications/etiology , Postoperative Complications/surgery , Length of Stay , Retrospective Studies , Treatment Outcome
19.
J Surg Res ; 288: 87-98, 2023 08.
Article in English | MEDLINE | ID: mdl-36963298

ABSTRACT

INTRODUCTION: Pancreatic surgery tends to have a high rate of postoperative complications due to its complex nature, significantly increasing hospital costs. Our aim was to describe the true association between complications and hospital costs in a national cohort of US patients. METHODS: The National Inpatient Sample was used to conduct a retrospective analysis of elective pancreatic resections performed between 2004 and 2017, categorizing them based on whether patients experienced major complications (MaC), minor complications (MiC), or no complications (NC). Multivariable quantile regression was used to analyze how costs varied at different percentiles of the cost curve. RESULTS: Of 37,893 patients, 45.3%, 28.6%, and 26.1% experienced NC, MiC, and MaC, respectively. Factors associated with MaC were a Charlson Comorbidity Index of ≥4, prolonged length of stay, proximal pancreatectomy, older age, male sex, and surgery performed at hospitals with a small number of beds or at urban nonteaching hospitals (all P < 0.01). Multivariable quantile regression revealed significant variation in MiC and MaC across the cost curve. At the 50th percentile, MiC increased the cost by $3352 compared to NC while MaC almost doubled the cost of the surgery, increasing it by $20,215 (both P < 0.01). The association between complications and cost was even greater at the 95th percentile, increasing the cost by $10,162 and $108,793 for MiC and MaC, respectively (P < 0.01). CONCLUSIONS: MiC and MaC were significantly associated with increased hospital costs. Furthermore, the relationship between MaC and costs was especially apparent at higher percentiles of the cost curve.


Subject(s)
Digestive System Surgical Procedures , Humans , Male , Length of Stay , Retrospective Studies , Digestive System Surgical Procedures/adverse effects , Hospitals , Hospital Costs , Postoperative Complications/epidemiology , Postoperative Complications/etiology
20.
Catheter Cardiovasc Interv ; 101(1): 79-86, 2023 01.
Article in English | MEDLINE | ID: mdl-36453459

ABSTRACT

OBJECTIVES: This clinical study evaluated the efficacy of a novel radiation shielding system for the cardiac catheterization laboratory designed to provide comprehensive protection that obviates the need for personal lead aprons. BACKGROUND: Invasive Cardiologists are exposed to occupational health hazards related directly to radiation exposure (RE) and indirectly to the orthopedic burden of wearing only partially protective lead aprons. Innovations to reduce these risks are warranted. A novel comprehensive shielding system (ProtegoTM , Image Diagnostics Inc, Fitchburg, Ma) has been validated in pre-clinical studies to provide excellent radiation protection, sufficient for the State of Michigan to certify it for use without need for personal lead aprons. METHODS: This clinical analysis measured RE to a single Physician operator utilizing the ProtegoTM shield (and not wearing personal lead apron) during routine cardiac catheterization procedures (diagnostic and interventional). RE was measured at both thyroid and waist level with a real-time dosimetry system (RaysafeTM , Billdal, Sweden), calculated on a median per case basis (mrems). Additional parameters collected included procedure type, access site, per case fluoroscopy time, and patient factors including body mass index. RESULTS: In n=98 cases (25% diagnostic, 75% interventional including 22% chronic total occlusions), median/case RE was 0.4 mrems (thyroid) and 0.2 mrems (waist). RE=0 in 12 cases. In no case did radiation exposure exceed 3.2 mrems. CONCLUSION: The ProtegoTM shield system provides excellent RE protection to the Physician operator, without the need for personal lead aprons and has the potential to reduce catheterization laboratory occupational health hazards.


Subject(s)
Occupational Exposure , Radiation Exposure , Radiation Protection , Humans , Treatment Outcome , Radiation Exposure/adverse effects , Radiation Exposure/prevention & control , Protective Clothing , Cardiac Catheterization/adverse effects , Occupational Exposure/adverse effects , Occupational Exposure/prevention & control , Radiation Dosage , Radiography, Interventional/adverse effects
SELECTION OF CITATIONS
SEARCH DETAIL
...