Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 36
Filter
1.
Ophthalmol Sci ; 5(1): 100525, 2025.
Article in English | MEDLINE | ID: mdl-39328823

ABSTRACT

Purpose: To assess the feasibility of a second-generation (44-channel) suprachoroidal retinal prosthesis for provision of functional vision in recipients with end-stage retinitis pigmentosa (RP) over 2.7 years. Design: Prospective, single-arm, unmasked interventional clinical trial. Participants: Four participants, with advanced RP and bare-light perception vision. Methods: The 44-channel suprachoroidal retinal prosthesis was implanted in the worse-seeing eye. Device stability, functionality, and adverse events were investigated at approximately 12-week intervals up to 140 weeks (2.7 years) postdevice activation. Main Outcome Measures: Serious adverse event (SAE) reporting, visual response outcomes, functional vision outcomes, and quality-of-life outcomes. Results: All 4 participants (aged 39-66 years, 3 males) were successfully implanted in 2018, and there were no device-related SAEs over the duration of the study. A mild postoperative subretinal hemorrhage was detected in 2 recipients, which cleared spontaneously within 2 weeks. OCT confirmed device stability and position under the macula. Improvements in localization abilities were demonstrated for all 4 participants in screen-based, tabletop, and orientation and mobility tasks. In addition, 3 of 4 participants recorded improvements in motion discrimination and 2 of 4 participants recorded substantial improvements in spatial discrimination and identification of tabletop objects. Participants reported their unsupervised use of the device included exploring new environments, detecting people, and safely navigating around obstacles. A positive effect of the implant on participants' daily lives in their local environments was confirmed by an orientation and mobility assessor and participant self-report. Emotional well-being was not impacted by device implantation or usage. Conclusions: The completed clinical study demonstrates that the suprachoroidal prosthesis raises no safety concerns and provides improvements in functional vision, activities of daily living, and observer-rated quality of life. Financial Disclosures: Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

2.
medRxiv ; 2024 Sep 12.
Article in English | MEDLINE | ID: mdl-39314940

ABSTRACT

Reticular pseudodrusen (RPD) signify a critical phenotype driving vision loss in age-related macular degeneration (AMD). Their detection is paramount in the clinical management of those with AMD, yet they remain challenging to reliably identify. We thus developed a deep learning (DL) model to segment RPD from 9,800 optical coherence tomography B-scans, and this model produced RPD segmentations that had higher agreement with four retinal specialists (Dice similarity coefficient [DSC]=0·76 [95% confidence interval [CI] 0·71-0·81]) than the agreement amongst the specialists (DSC=0·68, 95% CI=0·63-0·73; p <0·001). In five external test datasets consisting of 1,017 eyes from 812 individuals, the DL model detected RPD with a similar level of performance as two retinal specialists (area-under-the-curve of 0·94 [95% CI=0·92-0·97], 0·95 [95% CI=0·92-0·97] and 0·96 [95% CI=0·94-0·98] respectively; p ≥0·32). This DL model enables the automatic detection and quantification of RPD with expert-level performance, which we have made publicly available.

3.
Clin Exp Ophthalmol ; 2024 Aug 01.
Article in English | MEDLINE | ID: mdl-39089690

ABSTRACT

BACKGROUND: Nocturnal hypoxia is common, under-diagnosed and is found in the same demographic at risk of age-related macular degeneration (AMD). The objective of this study was to determine any association between nocturnal hypoxia and AMD, its severity, and the high-risk sub-phenotype of reticular pseudodrusen (RPD). METHODS: This cross-sectional study included participants aged ≥50 years with AMD, or normal controls, exclusive of those on treatment for obstructive sleep apnoea. All participants had at home, overnight (up to 3 nights) pulse oximetry recordings and multimodal imaging to classify AMD. Classification of Obstructive Sleep Apnea (OSA) was determined based on oxygen desaturation index [ODI] with mild having values of 5-15 and moderate-to-severe >15. RESULTS: A total of 225 participants were included with 76% having AMD, of which 42% had coexistent RPD. Of the AMD participants, 53% had early/intermediate AMD, 30% had geographic atrophy (GA) and 17% had neovascular AMD (nAMD). Overall, mild or moderate-to-severe OSAwas not associated with an increased odds of having AMD nor AMD with RPD (p ≥ 0.180). However, moderate-to-severe OSA was associated with increased odds of having nAMD (odds ratio = 6.35; 95% confidence interval = 1.18 to 34.28; p = 0.032), but not early/intermediate AMD or GA, compared to controls (p ≥ 0.130). Mild OSA was not associated with differences in odds of having AMD of any severity (p ≥ 0.277). CONCLUSIONS: There was an association between nocturnal hypoxia as measured by the ODI and nAMD. Hence, nocturnal hypoxia may be an under-appreciated important modifiable risk factor for nAMD.

4.
Front Cell Dev Biol ; 12: 1422764, 2024.
Article in English | MEDLINE | ID: mdl-38966426

ABSTRACT

Purpose: Extraocular electrical stimulation is known to provide neuroprotection for retinal cells in retinal and optic nerve diseases. Currently, the treatment approach requires patients to set up extraocular electrodes and stimulate potentially weekly due to the lack of an implantable stimulation device. Hence, a minimally-invasive implant was developed to provide chronic electrical stimulation to the retina, potentially improving patient compliance for long-term use. The aim of the present study was to determine the surgical and stimulation safety of this novel device designed for neuroprotective stimulation. Methods: Eight normally sighted adult feline subjects were monocularly implanted in the suprachoroidal space in the peripheral retina for 9-39 weeks. Charge balanced, biphasic, current pulses (100 µA, 500 µs pulse width and 50 pulses/s) were delivered continuously to platinum electrodes for 3-34 weeks. Electrode impedances were measured hourly. Retinal structure and function were assessed at 1-, 2-, 4-, 6- and 8-month using electroretinography, optical coherence tomography and fundus photography. Retina and fibrotic thickness were measured from histological sections. Randomized, blinded histopathological assessments of stimulated and non-stimulated retina were performed. Results: All subjects tolerated the surgical and stimulation procedure with no evidence of discomfort or unexpected adverse outcomes. The device position was stable after a post-surgery settling period. Median electrode impedance remained within a consistent range (5-10 kΩ) over time. There was no change in retinal thickness or function relative to baseline and fellow eyes. Fibrotic capsule thickness was equivalent between stimulated and non-stimulated tissue and helps to hold the device in place. There was no scarring, insertion trauma, necrosis, retinal damage or fibroblastic response in any retinal samples from implanted eyes, whilst 19% had a minimal histiocytic response, 19% had minimal to mild acute inflammation and 28% had minimal to mild chronic inflammation. Conclusion: Chronic suprathreshold electrical stimulation of the retina using a minimally invasive device evoked a mild tissue response and no adverse clinical findings. Peripheral suprachoroidal electrical stimulation with an implanted device could potentially be an alternative approach to transcorneal electrical stimulation for delivering neuroprotective stimulation.

5.
Clin Exp Ophthalmol ; 2024 May 30.
Article in English | MEDLINE | ID: mdl-38812454

ABSTRACT

BACKGROUND: To examine whether the clinical performance of predicting late age-related macular degeneration (AMD) development is improved through using multimodal imaging (MMI) compared to using colour fundus photography (CFP) alone, and how this compares with a basic prediction model using well-established AMD risk factors. METHODS: Individuals with AMD in this study underwent MMI, including optical coherence tomography (OCT), fundus autofluorescence, near-infrared reflectance and CFP at baseline, and then at 6-monthly intervals for 3-years to determine MMI-defined late AMD development. Four retinal specialists independently assessed the likelihood that each eye at baseline would progress to MMI-defined late AMD over 3-years with CFP, and then with MMI. Predictive performance with CFP and MMI were compared to each other, and to a basic prediction model using age, presence of pigmentary abnormalities, and OCT-based drusen volume. RESULTS: The predictive performance of the clinicians using CFP [AUC = 0.75; 95% confidence interval (CI) = 0.68-0.82] improved when using MMI (AUC = 0.79; 95% CI = 0.72-0.85; p = 0.034). However, a basic prediction model outperformed clinicians using either CFP or MMI (AUC = 0.85; 95% CI = 0.78-91; p ≤ 0.002). CONCLUSIONS: Clinical performance for predicting late AMD development was improved by using MMI compared to CFP. However, a basic prediction model using well-established AMD risk factors outperformed retinal specialists, suggesting that such a model could further improve personalised counselling and monitoring of individuals with the early stages of AMD in clinical practice.

6.
Invest Ophthalmol Vis Sci ; 65(5): 39, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38787546

ABSTRACT

Purpose: Post-saccadic oscillations (PSOs) reflect movements of gaze that result from motion of the pupil and lens relative to the eyeball rather than eyeball rotations. Here, we analyzed the characteristics of PSOs in subjects with age-related macular degeneration (AMD), retinitis pigmentosa (RP), and normal vision (NV). Our aim was to assess the differences in PSOs between people with vision loss and healthy controls because PSOs affect retinal image stability after each saccade. Methods: Participants completed a horizontal saccade task and their gaze was measured using a pupil-based eye tracker. Oscillations occurring in the 80 to 200 ms post-saccadic period were described with a damped oscillation model. We compared the amplitude, decay time constant, and frequency of the PSOs for the three different groups. We also examined the correlation between these PSO parameters and the amplitude, peak velocity, and final deceleration of the preceding saccades. Results: Subjects with vision loss (AMD, n = 6, and RP, n = 5) had larger oscillation amplitudes, longer decay constants, and lower frequencies than subjects with NV (n = 7). The oscillation amplitudes increased with increases in saccade deceleration in all three groups. The other PSO parameters, however, did not show consistent correlations with either saccade amplitude or peak velocity. Conclusions: Post-saccadic fixation stability in AMD and RP is reduced due to abnormal PSOs. The differences with respect to NV are not due to differences in saccade kinematics, suggesting that anatomic and neuronal variations affect the suspension of the iris and the lens in the patients' eyes.


Subject(s)
Fixation, Ocular , Macular Degeneration , Pupil , Retinitis Pigmentosa , Saccades , Humans , Saccades/physiology , Retinitis Pigmentosa/physiopathology , Female , Male , Fixation, Ocular/physiology , Middle Aged , Macular Degeneration/physiopathology , Aged , Pupil/physiology , Lens, Crystalline/physiopathology , Adult , Visual Acuity/physiology
7.
Sleep Breath ; 28(3): 1373-1379, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38504043

ABSTRACT

PURPOSE: Obstructive sleep apnoea (OSA) is common, yet often undiagnosed. Self-administered, overnight pulse oximetry (OPO) could screen for OSA in asymptomatic, older populations. However, the inter-night variability of OPO in an asymptomatic, older population is unknown. We determined the inter-night variability of home OPO parameters in an older population and correlated with sleep questionnaires. METHODS: Participants > 50 years without a diagnosis of OSA undertook home OPO for three consecutive nights and completed two sleep questionnaires (STOP-BANG (SBQ) and Epworth Sleepiness Score (ESS)). Analysis was performed with linear mixed models and Spearman's correlation coefficient. RESULTS: There was no difference in oxygen desaturation index (ODI), MeanSpO2, MinimumSpO2, and time spent with SpO2 < 90% (T90) across two or three nights (P ≥ 0.282). However, the variability of all parameters across nights increased with the magnitude of departure from normal values (P ≤ 0.002). All OPO parameters were associated with age (P ≤ 0.034) and body mass index (P ≤ 0.049). There was a weak correlation between three OPO parameters and SBQ (absolute ρ = 0.22 to 0.32; P ≤ 0.021), but not ESS (P ≥ 0.254). CONCLUSION: Inter-night variability of home OPO was minimal when values were near-normal in an older population. However, as values depart from normal, the inter-night variability increases, indicating the need for multiple night recordings. Low correlation to sleep questionnaires suggest the need for more robust OSA questionnaires in an asymptomatic population.


Subject(s)
Mass Screening , Oximetry , Sleep Apnea, Obstructive , Humans , Male , Female , Sleep Apnea, Obstructive/diagnosis , Sleep Apnea, Obstructive/epidemiology , Middle Aged , Aged , Surveys and Questionnaires , Polysomnography
8.
Retina ; 44(2): 214-221, 2024 Feb 01.
Article in English | MEDLINE | ID: mdl-37831941

ABSTRACT

PURPOSE: To investigate the prognostic value of quantifying optical coherence tomography (OCT)-defined hyperreflective foci (HRF) that do not correspond to hyperpigmentary abnormalities (HPAs) on color fundus photographs (CFPs)-HRF (OCT+/CFP-) -when considered in addition to HPA extent, for predicting late age-related macular degeneration development. This study sought to understand the impact of HRF (OCT+/CFP-) extent on visual sensitivity. METHODS: Two hundred eighty eyes from 140 participants with bilateral large drusen underwent imaging and microperimetry at baseline, and then 6-monthly for 3-years. The extent of HPAs on CFPs and HRF (OCT+/CFP-) on OCT was quantified at baseline. Predictive models for progression to late age-related macular degeneration, accounting for drusen volume and age, were developed using HPA extent, with and without HRF (OCT+/CFP-) extent. The association between HPA and HRF (OCT+/CFP-) extent with sector-based visual sensitivity was also evaluated. RESULTS: Incorporating HRF (OCT+/CFP-) extent did not improve the predictive performance for late age-related macular degeneration development ( P ≥ 0.32). Increasing HPA and HRF (OCT+/CFP-) extent in each sector were independently and significantly associated with reduced sector-based visual sensitivity ( P ≤ 0.004). CONCLUSION: The addition of HRF (OCT+/CFP-) extent to HPA extent did not improve the prediction of late age-related macular degeneration development. HRF (OCT+/CFP-) extent was also independently associated with local reductions in visual sensitivity, after accounting for HPAs.


Subject(s)
Macular Degeneration , Retinal Drusen , Humans , Macular Degeneration/diagnosis , Retina , Fundus Oculi , Diagnostic Techniques, Ophthalmological , Prognosis , Tomography, Optical Coherence/methods , Retinal Drusen/diagnosis
9.
Invest Ophthalmol Vis Sci ; 64(3): 1, 2023 03 01.
Article in English | MEDLINE | ID: mdl-36857076

ABSTRACT

Purpose: Most eye-movement studies in patients with visual field defects have examined the strategies that patients use while exploring a visual scene, but they have not investigated saccade kinematics. In healthy vision, saccade trajectories follow the remarkably stereotyped "main sequence": saccade duration increases linearly with saccade amplitude; peak velocity also increases linearly for small amplitudes, but approaches a saturation limit for large amplitudes. Recent theories propose that these relationships reflect the brain's attempt to optimize vision when planning eye movements. Therefore, in patients with bilateral retinal damage, saccadic behavior might differ to optimize vision under the constraints imposed by the visual field defects. Methods: We compared saccadic behavior of patients with central vision loss, due to age-related macular degeneration (AMD), and patients with peripheral vision loss, due to retinitis pigmentosa (RP), to that of controls with normal vision (NV) using a horizontal saccade task. Results: Both patient groups demonstrated deficits in saccade reaction times and target localization behavior, as well as altered saccade kinematics. Saccades were generally slower and the shape of the velocity profiles were often atypical, especially in the patients with RP. In the patients with AMD, the changes were far less dramatic. For both groups, saccade kinematics were affected most when the target was in the subjects' blind field. Conclusions: We conclude that defects of the central and peripheral retina have distinct effects on the saccade main sequence, and that visual inputs play an important role in planning the kinematics of a saccade.


Subject(s)
Macular Degeneration , Retinal Diseases , Retinitis Pigmentosa , Humans , Saccades , Eye Movements , Scotoma
10.
Transl Vis Sci Technol ; 12(3): 20, 2023 03 01.
Article in English | MEDLINE | ID: mdl-36943168

ABSTRACT

Purpose: Accurate mapping of phosphene locations from visual prostheses is vital to encode spatial information. This process may involve the subject pointing to evoked phosphene locations with their finger. Here, we demonstrate phosphene mapping for a retinal implant using eye movements and compare it with retinotopic electrode positions and previous results using conventional finger-based mapping. Methods: Three suprachoroidal retinal implant recipients (NCT03406416) indicated the spatial position of phosphenes. Electrodes were stimulated individually, and the subjects moved their finger (finger based) or their eyes (gaze based) to the perceived phosphene location. The distortion of the measured phosphene locations from the expected locations (retinotopic electrode locations) was characterized with Procrustes analysis. Results: The finger-based phosphene locations were compressed spatially relative to the expected locations all three subjects, but preserved the general retinotopic arrangement (scale factors ranged from 0.37 to 0.83). In two subjects, the gaze-based phosphene locations were similar to the expected locations (scale factors of 0.72 and 0.99). For the third subject, there was no apparent relationship between gaze-based phosphene locations and electrode locations (scale factor of 0.07). Conclusions: Gaze-based phosphene mapping was achievable in two of three tested retinal prosthesis subjects and their derived phosphene maps correlated well with the retinotopic electrode layout. A third subject could not produce a coherent gaze-based phosphene map, but this may have revealed that their phosphenes were indistinct spatially. Translational Relevance: Gaze-based phosphene mapping is a viable alternative to conventional finger-based mapping, but may not be suitable for all subjects.


Subject(s)
Eye Movements , Visual Prosthesis , Humans , Phosphenes , Vision Disorders , Retina/surgery
SELECTION OF CITATIONS
SEARCH DETAIL