Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Lancet Glob Health ; 12(3): e522-e529, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38365422

ABSTRACT

In rural settings worldwide, many people live in effective blood deserts without access to any blood transfusion. The traditional system of blood banking is logistically complex and expensive for many resource-restricted settings and demands innovative and multidisciplinary solutions. 17 international experts in medicine, industry, and policy participated in an exploratory process with a 2-day hybrid seminar centred on three promising innovative strategies for blood transfusions in blood deserts: civilian walking blood banks, intraoperative autotransfusion, and drone-based blood delivery. Participant working groups conducted literature reviews and interviews to develop three white papers focused on the current state and knowledge gaps of each innovation. Seminar discussion focused on defining blood deserts and developing innovation-specific implementation agendas with key research and policy priorities for future work. Moving forward, advocates should prioritise the identification of blood deserts and address the context-specific challenges for these innovations to alleviate the ongoing crisis in blood deserts.


Subject(s)
Blood Banks , Blood Transfusion , Humans , Policy , Consensus , Rural Population
2.
East Mediterr Health J ; 30(1): 60-67, 2024 Jan 21.
Article in English | MEDLINE | ID: mdl-38415337

ABSTRACT

Background: Following reports of an outbreak of HIV infection among children in Larkana District, Pakistan, an international team investigated the extent and cause of the outbreak between April and June 2019. Aims: To investigate the incidence of HIV among children in Larkana District, Pakistan and describe the distribution of cases by time, place and person. Methods: Self-referred persons were tested for HIV using the national testing protocol. Local epidemiology of HIV was reviewed to generate hypotheses. An infection prevention and control (IPC) team conducted site visits and reviewed IPC practices. Results: Between 25 April and 27 June 2019, a total of 30 191 persons were tested for HIV in Larkana District, and 876 of them tested positive. Of those who tested positive, 719 (82%) were children aged <15 years. Traditional skin piercing procedures and transmission from high-risk populations to children were ruled out during the investigation. Informative interviews with parents or guardians of a convenience sample of 211 children aged <15 years showed that 99% of children had an injection or infusion for medical treatment within the past 12 months. Our investigation identified lack of HIV prevalence data for the general population including tuberculosis patients and those who attended antenatal care services. Conclusions: Investigations indicate that unsafe healthcare practices in formal and informal healthcare settings as the most likely cause of the 2019 outbreak of HIV infection in Larkana, Pakistan. Measures should be taken to improve IPC practices at the facility level, especially in pediatric and antenatal care clinics.


Subject(s)
HIV Infections , Humans , Child , Female , Pregnancy , HIV Infections/epidemiology , HIV Infections/prevention & control , Pakistan/epidemiology , Disease Outbreaks , Risk Factors , Prenatal Care
3.
J Lab Physicians ; 11(4): 369-372, 2019.
Article in English | MEDLINE | ID: mdl-31929706

ABSTRACT

OBJECTIVE: The current study was conducted to evaluate the performance and screening effectiveness of commercially available rapid screening kits in comparison with chemiluminescence immunoassay (CLIA) and polymerase chain reaction (PCR). MATERIALS AND METHODS: This single-center, cross-sectional study was conducted at the Department of Pathology and Blood Transfusion Services, Shaheed Zulfiqar Ali Bhutto Medical University, PIMS, Islamabad, from January to April 2019. A total of 10 commercially available immunochromatographic test (ICT) devices and one CLIA kit (LIAISON XL) were tested for their sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy using 100 positive and 100 negative samples each for HBV and HCV, respectively. RESULTS: The sensitivities and specificities of ICT kits for hepatitis B surface antigen were 65% and 70% (Hightop), 67% and 85% (RightSign), 62% and 73% (Wondfo), 70% and 80% (Accu-Chek), 68% and 77% (Fastep), 73% and 85% (Abon), 77% and 83% (ImmuMed), 80% and 90% (Insta-Answer), 67% and 81% (BioCheck), and 72% and 83% CTK Biotech, respectively. Similarly, the sensitivities and specificities of different ICT kits for HCV were 69% and 80% (Hightop), 76% and 83% (RightSign), 69% and 81% (Wondfo), 78% and 79% (Accu-Check), 68% and 68% (Fastep), 63% and 73% (Abon), 71% and 70% (ImmuMed), 79% and 68% (Insta-Answer), 62% and 66% (BioChek), and 69% and 78% CTK Biotech, respectively. The sensitivity and specificity of Diasorin Liaison Murex assay for both HBV and HCV were found to be 100% when compared with PCR. The PPV, NPV and Accuracy were determined accordingly. CONCLUSION: Rapid testing ICT devices for both HBV and HCV available in Pakistan were found to have a variable degree of sensitivity and specificity when compared with CLIA and PCR. Comparatively expensive but quality methods are more reliable as compared to rapid devices.

SELECTION OF CITATIONS
SEARCH DETAIL
...