Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
AJNR Am J Neuroradiol ; 43(7): 998-1003, 2022 07.
Article in English | MEDLINE | ID: mdl-35738674

ABSTRACT

BACKGROUND AND PURPOSE: Flow diversion is an effective treatment for aneurysms of the ICA with compression-related neuro-ophthalmologic symptoms, especially when treatment is initiated early after symptom onset and aneurysm occlusion is complete. However, non-negligible complication rates have been reported. Our aim was to identify risk factors for morbidity/mortality and incomplete aneurysm occlusion. MATERIALS AND METHODS: We performed a secondary analysis of a previous publication, which included all patients treated with flow diversion for an unruptured aneurysm of the ICA with compression-related symptoms. RESULTS: Fifty-four patients with 54 aneurysms (48 women, 88.9%; mean age, 59.2 [SD, 15.9] years; range, 21-86 years) treated with flow diversion were included. We observed morbidity and mortality rates of 7.4% and 3.7%. Increasing age (OR per decade, 3.2; 95% CI, 1.23-8.49; P = .02) and dual-antiplatelet therapy with ticagrelor (OR, 13.9; 95% CI, 1.16-165.97; P = .04) were significantly associated with morbidity/mortality. After a median follow-up of 13.3 [SD, 10.5] months, the rates of complete aneurysm occlusion, neck remnant, and aneurysm remnant were 74%, 14%, and 12%. Incomplete occlusion at follow-up was less frequently observed in aneurysms treated with additional coil embolization (OR, 0.1; 95% CI, 0.01-0.86; P = .04). CONCLUSIONS: Although a promising treatment for compressive ICA aneurysms, flow diversion carries a relevant risk for complications and incomplete aneurysm occlusion. Our results may help identify patients in which flow diversion may not be the ideal treatment method. Additional coil embolization increased the likelihood of complete aneurysm occlusion at follow-up.


Subject(s)
Embolization, Therapeutic , Endovascular Procedures , Intracranial Aneurysm , Blood Vessel Prosthesis , Embolization, Therapeutic/methods , Endovascular Procedures/methods , Female , Humans , Intracranial Aneurysm/complications , Intracranial Aneurysm/surgery , Middle Aged , Morbidity , Retrospective Studies , Stents , Treatment Outcome
2.
J Clin Neurosci ; 89: 33-38, 2021 Jul.
Article in English | MEDLINE | ID: mdl-34119289

ABSTRACT

BACKGROUND: Complete reperfusion (mTICI 3) in anterior circulation ischemic stroke patients after a single mechanical thrombectomy (MT) pass has been identified as a predictor of favorable outcome (modified Rankin Score 0-2) and defined as true first-pass effect recently. This effect has not yet been demonstrated in posterior circulation ischemic stroke. We hypothesized a true first-pass effect for the subgroup of acute basilar artery occlusions (BAO). METHODS: Consecutive patients with acute thromboembolic occlusions in the posterior circulation, treated between 2010 and 2017, were screened and all BAO patients with complete angiographic reperfusion and known symptom onset included for unmatched and matched analysis after adjustment for multiple confounding factors (demographics, time intervals, stroke severity, posterior circulation Alberta Stroke Program early computed tomography Score and comorbidity. The primary objective was outcome at 90 days between matched cohorts of single pass vs. multi pass complete reperfusion patients. RESULTS: 90 MTs in BAO were analyzed, yielding 56 patients with known symptom onset, in whom we achieved complete reperfusion (mTICI 3), depending on whether complete reperfusion was achieved after a single pass (n = 28) or multiple passes (n = 28). Multivariable analysis of 56 non-matched patients revealed a significant association between first-pass complete reperfusion and favorable outcome (p < 0.01). In matched cohorts (n = 7 vs. n = 7), favorable outcome was only seen if complete reperfusion was achieved after a single pass (86% vs. 0%). CONCLUSION: Single pass complete reperfusion in acute basilar artery occlusion is an independent predictor of favorable outcome. Achieving complete reperfusion after multiple passes might impair favorable patient recovery.


Subject(s)
Basilar Artery/surgery , Cerebral Revascularization/methods , Cerebrovascular Disorders/surgery , Stroke/surgery , Thrombectomy/trends , Aged , Aged, 80 and over , Basilar Artery/diagnostic imaging , Cerebrovascular Disorders/complications , Cerebrovascular Disorders/diagnostic imaging , Female , Humans , Male , Middle Aged , Reperfusion/methods , Retrospective Studies , Stroke/diagnostic imaging , Stroke/etiology , Thrombectomy/methods , Treatment Outcome
3.
AJNR Am J Neuroradiol ; 42(3): 516-523, 2021 03.
Article in English | MEDLINE | ID: mdl-33384288

ABSTRACT

BACKGROUND AND PURPOSE: CTA provides a noninvasive alternative technique to DSA in the follow-up after endovascular aneurysm treatment to evaluate aneurysm occlusion and exclude intraluminal narrowing after stent or flow-diverter implantation; however, assessability may be impeded by stent material artifacts. The objective of this in vitro study was to compare the visual assessability of different conventional stents and flow diverters as well as different reconstructions of dual-layer CT images. MATERIALS AND METHODS: Four conventional intracranial stents and 4 flow diverters were implanted in identical aneurysm phantoms. Conventional and monoenergetic images (40, 50, 60, 90, 120, 180 keV) were acquired to evaluate attenuation alteration, visible lumen diameter, and SNR. Image quality was rated subjectively by 2 independent radiologists using a 4-point Likert scale. RESULTS: Low kiloelectron volt (40-60 keV) monoenergetic reconstructions showed an improved SNR and an improved lumen density ratio compared with high kiloelectron volt reconstructions (90-180 keV) and conventional reconstructions, however without reaching significance compared with the latter. Assessment of the adjacent aneurysm and subjective evaluation was not affected by the imaging technique and stent type. Artifact susceptibility varied with the device used and increased among flow diverters. CONCLUSIONS: Low kiloelectron volt reconstructions improved the assessment of the stent lumen in comparison with high kiloelectron volt reconstructions. No significant improvement in image quality could be shown compared with conventional images. For some devices, iodine-specific reconstructions led to severe artifacts and are therefore not recommended. There was no relevant improvement in the assessability of the adjacent aneurysm.


Subject(s)
Aneurysm/diagnostic imaging , Aneurysm/therapy , Computed Tomography Angiography/methods , Image Processing, Computer-Assisted/methods , Artifacts , Endovascular Procedures , Female , Humans , Male , Middle Aged , Phantoms, Imaging , Stents
4.
Eur Radiol ; 31(6): 4148-4155, 2021 Jun.
Article in English | MEDLINE | ID: mdl-33341907

ABSTRACT

OBJECTIVES: The objective of this study was to compare clinical outcome and procedural differences of mechanical thrombectomy (MT) during on-call with regular operating hours. We particularly focused on dosimetric data which may serve as potential surrogates for patient outcome. METHODS: A total of 246 consecutive patients who underwent MT in acute anterior circulation stroke between November 2017 and March 2020 were retrospectively included. Patients treated (1) during standard operational hours (n = 102), (2) daytime on-call duty (n = 38) and (3) nighttime on-call duty (n = 106) were compared with respect to their pre-interventional status, procedural specifics, including dosimetrics (dose area product (DAP), fluoroscopy time and procedural time), and outcome. RESULTS: The collectives treated outside the regular operational hours showed an increased in-hospital mortality (standard operational hours 7% (7/102), daytime on-call duty 16% (6/38), nighttime on-call duty 20% (21/106), p = 0.02). Neither the dosimetric parameters nor baseline characteristics other procedural specifics and outcome parameters differed significantly between groups (p > 0.05 each). In most cases (> 90%), a successful reperfusion was achieved (TICI ≥ 2b). CONCLUSIONS: We found an increased in-hospital mortality in patients admitted at night and during weekends which was not explained by technical aspects of MT. KEY POINTS: • There is an increased mortality of stroke patients admitted at night and on weekends. • This is not explained by technical aspects of mechanical thrombectomy. • There were no statistical differences in the comparison of parameters linked to the radiation exposure, such as DAP, fluoroscopy time and procedure time.


Subject(s)
Brain Ischemia , Stroke , Humans , Reperfusion , Retrospective Studies , Stroke/therapy , Thrombectomy , Treatment Outcome
5.
J Clin Neurosci ; 75: 117-121, 2020 May.
Article in English | MEDLINE | ID: mdl-32173154

ABSTRACT

Stent protected Angioplasty of extracranial carotid artery stenosis using the dual-layered CGUARD stent is a novel treatment option. In this study we evaluate the feasibility and the safety of the CGUARD in symptomatic and asymptomatic patients in comparison to Casper-RX and Wallstent. This is a multi-center study of consecutive patients treated with the CGUARD, Casper-RX and Wallstent at two German high volume neurovascular centers between April 2017 and May 2018. Patient characteristics, neuroimaging data and angiographic outcome were retrospectively analyzed. The primary end points of the study were acute occlusion of the carotid stent and symptomatic intracerebral hemorrhage (sICH). Carotid artery stenting was performed in 76 patients; of those 26 (34%) were treated with the CGUARD, 25 (33%) with Casper-RX, and 25 (33%) with Wallstent. In 58/76 (76%) cases carotid artery stenosis was symptomatic with a median baseline National Institutes of Health Stroke Scale of 4. Angioplasty and stenting as part of a mechanical thrombectomy for acute ischemic stroke was performed in 25/76 (33%) patients. Baseline patient characteristics were similar between the treatment groups, except for a higher portion of scheduled cases in the Casper-RX group. There were no significant differences in the rate of acute in stent occlusions (CGUARD, 2/26 (8%); Casper-RX, 1/25(4%); Wallstent, 1/25 (4%)) and postinterventional sICH (1/26 (4%), 0/25(0%), 0/25 (0%)). Clinical outcome at discharge did not differ between groups. Treatment of carotid artery stenosis using CGUARD is feasible with a good safety profile comparable to that of Casper-RX and Wallstent.


Subject(s)
Carotid Stenosis/therapy , Stents/standards , Aged , Angioplasty/methods , Brain Ischemia/therapy , Carotid Stenosis/surgery , Endovascular Procedures/methods , Female , Germany , Humans , Male , Middle Aged , Retrospective Studies , Stroke/therapy , Treatment Outcome
6.
Nature ; 576(7787): 416-422, 2019 12.
Article in English | MEDLINE | ID: mdl-31853084

ABSTRACT

Magnetic topological insulators are narrow-gap semiconductor materials that combine non-trivial band topology and magnetic order1. Unlike their nonmagnetic counterparts, magnetic topological insulators may have some of the surfaces gapped, which enables a number of exotic phenomena that have potential applications in spintronics1, such as the quantum anomalous Hall effect2 and chiral Majorana fermions3. So far, magnetic topological insulators have only been created by means of doping nonmagnetic topological insulators with 3d transition-metal elements; however, such an approach leads to strongly inhomogeneous magnetic4 and electronic5 properties of these materials, restricting the observation of important effects to very low temperatures2,3. An intrinsic magnetic topological insulator-a stoichiometric well ordered magnetic compound-could be an ideal solution to these problems, but no such material has been observed so far. Here we predict by ab initio calculations and further confirm using various experimental techniques the realization of an antiferromagnetic topological insulator in the layered van der Waals compound MnBi2Te4. The antiferromagnetic ordering  that MnBi2Te4  shows makes it invariant with respect to the combination of the time-reversal and primitive-lattice translation symmetries, giving rise to a ℤ2 topological classification; ℤ2 = 1 for MnBi2Te4, confirming its topologically nontrivial nature. Our experiments indicate that the symmetry-breaking (0001) surface of MnBi2Te4 exhibits a large bandgap in the topological surface state. We expect this property to eventually enable the observation of a number of fundamental phenomena, among them quantized magnetoelectric coupling6-8 and axion electrodynamics9,10. Other exotic phenomena could become accessible at much higher temperatures than those reached so far, such as the quantum anomalous Hall effect2 and chiral Majorana fermions3.

7.
Eur Radiol ; 29(11): 5941-5949, 2019 Nov.
Article in English | MEDLINE | ID: mdl-31041562

ABSTRACT

OBJECTIVE: To evaluate feasibility and diagnostic performance of multi-level calcium suppression in spectral detector computed tomography (SDCT) for assessment of bone metastasis. MATERIALS AND METHODS: Retrospective IRB-approved study on 21 patients who underwent SDCT (120 kV, reference mAs 116) and MRI. Thoracic and lumbar vertebrae (n = 357) were included and categorized as normal (n = 133) or metastatic (n = 203) based on MRI (STIR, T1w, ±contrast). The multi-level virtual non-calcium (VNCa) algorithm computes dynamic soft tissue/calcium pairs allowing for computation of different suppression index levels to address inter-individual variance of prevalent calcium composition weights. We computed images with low, medium, and high calcium suppression indices and compared them with conventional images (VNCa_low/med/high and conventional images (CI)). For quantitative image analysis, regions of interest were placed in normal and metastatic bone. Two readers reviewed the datasets independently in multiple sessions. They determined the presence of vertebral metastases on a per vertebra basis using a binary scale. Statistic assessment was performed using ANOVA with Tukey HSD, Student's T test, and ROC analysis. RESULTS: Attenuation of both normal and metastatic bone was lower in VNCa images than that in conventional images (e.g., CI/VNCa_low, - 46.3 to 238.8 HU/343.3-60.2 HU; p ≤ 0.05). VNCa_low+med improved separation of normal and metastatic bone in ROC analysis (AUC, CI/VNCa_low/VNCa_med = 0.74/0.95/0.98; p ≤ 0.05). In subjective analysis, both sensitivity and specificity were clearly improved in VNCa_low as compared with CI (0.85/0.84 versus 0.78/0.82). Readers showed a good inter-rater reliability (kappa = 0.65). CONCLUSIONS: Multi-level VNCa reconstructed from SDCT improve quantitative separation of normal and metastatic bone and subjective determination of bone metastases when using low to intermediate calcium suppression indices. KEY POINTS: • Spectral detector CT allows for multi-level calcium suppression in CT images and low and medium calcium suppression indices improved separation of normal and metastatic bone. • Thus, multi-level calcium suppression allows to optimize image contrast in regard to dedicated pathologies. • Low-level virtual non-calcium images (index 25-50) improved diagnostic performance regarding detection of metastasis.


Subject(s)
Bone Marrow Diseases/diagnostic imaging , Calcium , Spinal Neoplasms/secondary , Tomography, X-Ray Computed/methods , Adult , Algorithms , Bone Marrow/diagnostic imaging , Epidemiologic Methods , Female , Humans , Lumbar Vertebrae/diagnostic imaging , Magnetic Resonance Imaging/methods , Male , Middle Aged , Spinal Neoplasms/diagnostic imaging , Thoracic Vertebrae/diagnostic imaging
8.
Eur J Radiol ; 104: 136-142, 2018 Jul.
Article in English | MEDLINE | ID: mdl-29857859

ABSTRACT

OBJECTIVES: Image quality in head and neck imaging is often severely hampered by artifacts arising from dental implants. This study evaluates metal artifact (MA) reduction using virtual monoenergetic images (VMI) compared to conventional CT images (CI) from spectral-detector computed tomography (SDCT). METHODS: 38 consecutive patients with dental implants were included in this retrospective study. All examinations were performed using a SDCT (IQon, Philips, Best, The Netherlands). Images were reconstructed as conventional images (CI) and as VMI in a range of 40-200 keV (10 keV increment). Quantitative image analysis was performed ROI-based by measurement of attenuation (HU) and standard deviation in most pronounced hypo- and hyperdense artifact, fat and soft tissue with presence of artifacts. Qualitatively, extent of artifact reduction, assessment of soft palate and cheeks were rated on 5-point Likert-scales by two radiologists. Statistical data evaluation included ANOVA and Wilcoxon-test with correction for multiple comparisons; interrater-agreement was determined by intraclass-correlation coefficient (ICC). RESULTS: The hypo- and hyperattenuating artifacts showed an increase and decrease of HU-values in VMIhigh (CI/VMI200 keV: -218.7/-174.4 HU, p = 0.1; and 309.8/119.2, p ≤ 0.05, respectively). Artifacts in the fat, as depicted by image noise did also decrease in VMIhigh (CI/VMI200 keV: 23.9/16.4, p ≤ 0.05). Qualitatively, hyperdense artifacts were decreased significantly in VMI ≥100 keV (e.g. CI/VMI200 keV: 2(1-3)/3(1-5), p ≤ 0.05). Artifact reduction resulted in improved assessment of the soft palate and cheeks (e.g. CI/VMI200 keV: 2(1-4)/3(1-5) and 2(1-5)/3(1-5), p ≤ 0.05). Overall interrater agreement was good (ICC = 0.77). CONCLUSIONS: Virtual monoenergetic images from SDCT reduce metal artifacts from dental implants and improve diagnostic assessment of surrounding soft tissue.


Subject(s)
Artifacts , Dental Implants , Radiographic Image Interpretation, Computer-Assisted/methods , Adult , Aged , Aged, 80 and over , Female , Head and Neck Neoplasms/diagnostic imaging , Humans , Male , Metals , Middle Aged , Phantoms, Imaging , Radiographic Image Enhancement , Reproducibility of Results , Retrospective Studies , Sensitivity and Specificity , Tomography, X-Ray Computed/methods
9.
Skeletal Radiol ; 47(2): 195-201, 2018 Feb.
Article in English | MEDLINE | ID: mdl-28932962

ABSTRACT

OBJECTIVE: Aim of this study was to assess the artifact reduction in patients with orthopedic hardware in the spine as provided by (1) metal-artifact-reduction algorithms (O-MAR) and (2) virtual monoenergetic images (MonoE) as provided by spectral detector CT (SDCT) compared to conventional iterative reconstruction (CI). METHODS: In all, 28 consecutive patients with orthopedic hardware in the spine who underwent SDCT-examinations were included. CI, O-MAR and MonoE (40-200 keV) images were reconstructed. Attenuation (HU) and noise (SD) were measured in order to calculate signal-to-noise ratio (SNR) of paravertebral muscle and spinal canal. Subjective image quality was assessed by two radiologists in terms of image quality and extent of artifact reduction. RESULTS: O-MAR and high-keV MonoE showed significant decrease of hypodense artifacts in terms of higher attenuation as compared to CI (CI vs O-MAR, 200 keV MonoE: -396.5HU vs. -115.2HU, -48.1HU; both p ≤ 0.001). Further, artifacts as depicted by noise were reduced in O-MAR and high-keV MonoE as compared to CI in (1) paravertebral muscle and (2) spinal canal-CI vs. O-MAR/200 keV: (1) 34.7 ± 19.0 HU vs. 26.4 ± 14.4 HU, p ≤ 0.05/27.4 ± 16.1, n.s.; (2) 103.4 ± 61.3 HU vs. 72.6 ± 62.6 HU/60.9 ± 40.1 HU, both p ≤ 0.001. Subjectively both O-MAR and high-keV images yielded an artifact reduction in up to 24/28 patients. CONCLUSION: Both, O-MAR and high-keV MonoE reconstructions as provided by SDCT lead to objective and subjective artifact reduction, thus the combination of O-MAR and MonoE seems promising for further reduction.


Subject(s)
Algorithms , Artifacts , Internal Fixators , Radiographic Image Interpretation, Computer-Assisted/methods , Spine/diagnostic imaging , Tomography, X-Ray Computed/methods , Aged , Female , Humans , Male , Middle Aged , Radiographic Image Enhancement/methods , Signal-To-Noise Ratio
SELECTION OF CITATIONS
SEARCH DETAIL
...