Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Database
Language
Publication year range
1.
J Biomech Eng ; 146(9)2024 Sep 01.
Article in English | MEDLINE | ID: mdl-38581371

ABSTRACT

Understanding the natural biomechanics of walking at different speeds and activities is crucial to develop effective assistive devices for persons with lower-limb impairments. While continuous measures such as joint angle and moment are well-suited for biomimetic control of robotic systems, whole-stride summary metrics are useful for describing changes across behaviors and for designing and controlling passive and semi-active devices. Dynamic mean ankle moment arm (DMAMA) is a whole-stride measure representing the moment arm of the ground reaction impulse about the ankle joint-effectively, how "forefoot-dominated" or "hindfoot-dominated" a movement is. DMAMA was developed as a target and performance metric for semi-active devices that adjust once per stride. However, for implementation in this application, DMAMA must be characterized across various activities in unimpaired individuals. In our study, unimpaired participants walked at "slow," "normal," and "fast" self-selected speeds on level ground and at a normal self-selected speed while ascending and descending stairs and a 5-degree incline ramp. DMAMA measured from these activities displayed a borderline-significant negative sensitivity to walking speed, a significant positive sensitivity to ground incline, and a significant decrease when ascending stairs compared to descending. The data suggested a nonlinear relationship between DMAMA and walking speed; half of the participants had the highest average DMAMA at their "normal" speed. Our findings suggest that DMAMA varies substantially across activities, and thus, matching DMAMA could be a valuable metric to consider when designing biomimetic assistive lower-limb devices.


Subject(s)
Walking , Humans , Walking/physiology , Male , Biomechanical Phenomena , Female , Adult , Mechanical Phenomena , Ankle Joint/physiology , Young Adult , Ankle/physiology , Arm/physiology
2.
Article in English | MEDLINE | ID: mdl-37663049

ABSTRACT

Wearable sensors offer a unique opportunity to study movement in ecological contexts - that is, outside the laboratory where movement happens in ordinary life. This article discusses the purpose, means, and impact of using wearable sensors to assess movement context, kinematics, and kinetics during locomotion, and how this information can be used to better understand and influence movement. We outline the types of information wearable sensors can gather and highlight recent developments in sensor technology, data analysis, and applications. We close with a vision for important future research and key questions the field will need to address to bring the potential benefits of wearable sensing to fruition.

3.
Exp Gerontol ; 173: 112102, 2023 03.
Article in English | MEDLINE | ID: mdl-36693530

ABSTRACT

Changes in old age that contribute to the complex issue of an increased metabolic cost of walking (mass-specific energy cost per unit distance traveled) in older adults appear to center at least in part on changes in gait biomechanics. However, age-related changes in energy metabolism, neuromuscular function and connective tissue properties also likely contribute to this problem, of which the consequences are poor mobility and increased risk of inactivity-related disease and disability. The U.S. National Institute on Aging convened a workshop in September 2021 with an interdisciplinary group of scientists to address the gaps in research related to the mechanisms and consequences of changes in mobility in old age. The goal of the workshop was to identify promising ways to move the field forward toward improving gait performance, decreasing energy cost, and enhancing mobility for older adults. This report summarizes the workshop and brings multidisciplinary insight into the known and potential causes and consequences of age-related changes in gait biomechanics. We highlight how gait mechanics and energy cost change with aging, the potential neuromuscular mechanisms and role of connective tissue in these changes, and cutting-edge interventions and technologies that may be used to measure and improve gait and mobility in older adults. Key gaps in the literature that warrant targeted research in the future are identified and discussed.


Subject(s)
National Institute on Aging (U.S.) , Walking , United States , Biomechanical Phenomena , Gait
4.
PLoS One ; 15(10): e0241339, 2020.
Article in English | MEDLINE | ID: mdl-33095823

ABSTRACT

Studies have shown that human gait entrains to rhythmic bursts of ankle torque for perturbation intervals both slightly shorter and slightly longer than the natural stride period while walking on a treadmill and during overground walking, with phase alignment such that the torque adds to ankle push-off. This study investigated whether human gait also entrains to align the phase of rhythmic electrical stimulation of the gastrocnemius muscle with the timing of ankle push-off. In addition, this study investigated the muscle response to electrical stimulation at different phases of the gait cycle. We found that for both treadmill and overground walking entrainment was observed with phasing that aligned the stimuli with ankle push-off or just before foot contact. Achilles tendon wave speed measurements showed a significant difference (increase) in tendon load when electrical stimulation was applied just after foot contact and during swing phase, with a greater increase for higher amplitudes of electrical stimulation. However, stimulation did not increase tendon load when the timing coincided with push-off. Stride period measurements also suggest the effect of electrical stimulation is sensitive to the gait phase it is applied. These results confirmed that timing aligned with push-off is an attractor for electrical stimulation-induced perturbations of the medial gastrocnemius, and that the muscle response to stimulation is sensitive to timing and amplitude. Future research should investigate other muscles and timings and separate sensory vs. motor contributions to these phenomena.


Subject(s)
Gait/physiology , Healthy Volunteers , Muscle, Skeletal/physiology , Achilles Tendon/physiology , Biomechanical Phenomena , Electric Stimulation , Female , Humans , Walking/physiology
5.
J Biomech Eng ; 142(7)2020 07 01.
Article in English | MEDLINE | ID: mdl-31891376

ABSTRACT

The human foot-ankle complex uses heel-to-toe ground contact progression in walking, but primarily forefoot contact in high-speed running. This qualitative change in ankle control is clear to the runner, but current measures of ankle behavior cannot isolate the effect, and it is unknown how it changes across moderate speeds. We investigated this dynamic ankle control across a range of walking and running speeds using a new measure, the dynamic mean ankle moment arm (DMAMA): the ratio of sagittal ankle moment impulse to ground reaction force impulse on a single limb. We hypothesized that DMAMA would increase with speed in both walking and running, indicating more forefoot-dominated gait with ground reaction forces more anterior to the ankle. Human subjects walked (1.0-2.0 m/s) and ran (2.25-5.25 m/s) on an instrumented treadmill with motion capture and pressure insoles to estimate DMAMA. DMAMA decreased with increasing walking speed, then increased upon the transition to running, and increased further with increasing running speed. These results provide quantitative evidence that walking becomes more hindfoot-dominated as speed increases-similar to behavior during acceleration-and that running is more forefoot-dominated than walking. The instantaneous center of pressure (COP) at initial ground contact did not follow the same trends. The discrepancy highlights the value of DMAMA in summarizing ankle control across the whole stance phase. DMAMA may provide a useful outcome metric for evaluating biomimetic prostheses and for quantifying foot contact styles in running.


Subject(s)
Gait , Adult , Arm , Biomechanical Phenomena , Humans , Lower Extremity
6.
Sensors (Basel) ; 19(8)2019 Apr 24.
Article in English | MEDLINE | ID: mdl-31022889

ABSTRACT

Assessing interventions for mobility disorders using real-life movement remains an unsolved problem. We propose a new method combining the strengths of traditional laboratory studies where environment is strictly controlled, and field-based studies where subjects behave naturally. We use a foot-mounted inertial sensor, a GPS receiver and a barometric altitude sensor to reconstruct a subject's path and detailed foot movement, both indoors and outdoors, during days-long measurement using strapdown navigation and sensor fusion algorithms. We cluster repeated movement paths based on location, and propose that on these paths, most environmental and behavioral factors (e.g., terrain and motivation) are as repeatable as in a laboratory. During each bout of movement along a frequently repeated path, any synchronized measurement can be isolated for study, enabling focused statistical comparison of different interventions. We conducted a 10-day test on one subject wearing athletic shoes and sandals each for five days. The algorithm detected four frequently-repeated straight walking paths with at least 300 total steps and repetitions on at least three days for each condition. Results on these frequently-repeated paths indicated significantly lower foot clearance and shorter stride length and a trend toward decreased stride width when wearing athletic shoes vs. sandals. Comparisons based on all straight walking were similar, showing greater statistical power, but higher variability in the data. The proposed method offers a new way to evaluate how mobility interventions affect everyday movement behavior.


Subject(s)
Gait Analysis/methods , Wearable Electronic Devices , Accelerometry/methods , Algorithms , Gait/physiology , Humans , Range of Motion, Articular/physiology , Walking/physiology
7.
Front Neurol ; 9: 1036, 2018.
Article in English | MEDLINE | ID: mdl-30619024

ABSTRACT

This literature review addressed wearable sensor systems to monitor motor symptoms in individuals with Parkinson's disease (PD) during activities of daily living (ADLs). Specifically, progress in monitoring tremor, freezing of gait, dyskinesia, bradykinesia, and hypokinesia was reviewed. Twenty-seven studies were found that met the criteria of measuring symptoms in a home or home-like setting, with some studies examining multiple motor disorders. Accelerometers, gyroscopes, and electromyography sensors were included, with some studies using more than one type of sensor. Five studies measured tremor, five studies examined bradykinesia or hypokinesia, thirteen studies included devices to measure dyskinesia or motor fluctuations, and ten studies measured akinesia or freezing of gait. Current sensor technology can detect the presence and severity of each of these symptoms; however, most systems require sensors on multiple body parts, which is challenging for remote or ecologically valid observation. Different symptoms are detected by different sensor placement, suggesting that the goal of detecting all symptoms with a reduced set of sensors may not be achievable. For the goal of monitoring motor symptoms during ADLs in a home setting, the measurement system should be simple to use, unobtrusive to the wearer and easy for an individual with PD to put on and take off. Machine learning algorithms such as neural networks appear to be the most promising way to detect symptoms using a small number of sensors. More work should be done validating the systems during unscripted and unconstrained ADLs rather than in scripted motions.

8.
Hum Mov Sci ; 54: 154-171, 2017 Aug.
Article in English | MEDLINE | ID: mdl-28499159

ABSTRACT

Many studies have reported the effects of different foot prostheses on gait, but most results cannot be generalized because the prostheses' properties are seldom reported. We varied hindfoot and forefoot stiffness in an experimental foot prosthesis, in increments of 15N/mm, and tested the parametric effects of these variations on treadmill walking in unilateral transtibial amputees, at speeds from 0.7 to 1.5m/s. We computed outcomes such as prosthesis energy return, center of mass (COM) mechanics, ground reaction forces, and joint mechanics, and computed their sensitivity to component stiffness. A stiffer hindfoot led to reduced prosthesis energy return, increased ground reaction force (GRF) loading rate, and greater stance-phase knee flexion and knee extensor moment. A stiffer forefoot resulted in reduced prosthetic-side ankle push-off and COM push-off work, and increased knee extension and knee flexor moment in late stance. The sensitivity parameters obtained from these tests may be useful in clinical prescription and further research into compensatory mechanisms of joint function.


Subject(s)
Artificial Limbs , Foot/physiology , Amputation, Surgical , Amputees , Ankle Joint/physiology , Ankle Joint/physiopathology , Biomechanical Phenomena/physiology , Exercise Test , Forefoot, Human/physiology , Gait/physiology , Humans , Knee Joint/physiology , Knee Joint/physiopathology , Prosthesis Design , Walking/physiology
9.
IEEE Trans Neural Syst Rehabil Eng ; 23(5): 776-85, 2015 Sep.
Article in English | MEDLINE | ID: mdl-25222950

ABSTRACT

Unilateral lower-limb amputees exhibit asymmetry in many gait features, such as ground force, step time, step length, and joint mechanics. Although these asymmetries result from weak prosthetic-side push-off, there is no proven mechanistic explanation of how that impairment propagates to the rest of the body. We used a simple dynamic walking model to explore possible consequences of a unilateral impairment similar to that of a transtibial amputee. The model compensates for reduced push-off work from one leg by performing more work elsewhere, for example during the middle of stance by either or both legs. The model predicts several gait abnormalities, including slower forward velocity of the body center-of-mass during intact-side stance, greater energy dissipation in the intact side, and more positive work overall. We tested these predictions with data from unilateral transtibial amputees (N = 11) and nonamputee control subjects (N = 10) walking on an instrumented treadmill. We observed several predicted asymmetries, including forward velocity during stance phases and energy dissipation from the two limbs, as well as greater work overall. Secondary adaptations, such as to reduce discomfort, may exacerbate asymmetry, but these simple principles suggest that some asymmetry may be unavoidable in cases of unilateral limb loss.


Subject(s)
Amputation Stumps/physiopathology , Foot/physiopathology , Gait Disorders, Neurologic/physiopathology , Gait , Leg/physiopathology , Models, Biological , Computer Simulation , Humans , Physical Exertion , Stress, Mechanical
SELECTION OF CITATIONS
SEARCH DETAIL
...