1.
J Biomed Opt ; 27(2)2022 02.
Article in English | MEDLINE | ID: mdl-35166086

ABSTRACT

SIGNIFICANCE: Corneal cross-linking (CXL) is a well-known procedure for treating certain eye disorders such as keratoconus. However, characterization of the biomechanical changes in the cornea as a result of this procedure is still under active research. Specifically, there is a clinical need for high-resolution characterization of individual corneal layers. AIM: A high-resolution elastography method in conjunction with a custom optical coherence tomography system is used to track these biomechanical changes in individual corneal layers. Pre- and post-treatment analysis for both low-dose and high-dose CXL experiments are performed. APPROACH: A recently developed elastography technique that utilizes the theory of reverberant shear wave fields, with optical coherence tomography as the modality, is applied to pig corneas ex vivo to evaluate elasticity changes associated with corneal CXL. Sets of low-dose and high-dose CXL treatments are evaluated before and after treatments with three pairs of pig corneas per experiment. RESULTS: The reverberant three-dimensional (3D) optical coherence elastography (OCE) technique can identify increases in elasticity associated with both low-dose and high-dose CXL treatments. There is a notable graphical difference between low-dose and high-dose treatments. In addition, the technique is able to identify which layers of the cornea are potentially affected by the CXL procedure and provides insight into the nonlinearity of the elasticity changes. CONCLUSIONS: The reverberant 3D OCE technique can identify depth-resolved changes in elasticity of the cornea associated with CXL procedures. This method could be translated to assess and monitor CXL efficacy in various clinical settings.


Subject(s)
Elasticity Imaging Techniques , Animals , Biomechanical Phenomena , Collagen , Cornea/diagnostic imaging , Cross-Linking Reagents , Elasticity Imaging Techniques/methods , Photosensitizing Agents/pharmacology , Photosensitizing Agents/therapeutic use , Riboflavin/pharmacology , Swine , Tomography, Optical Coherence , Ultraviolet Rays
2.
Curr Eye Res ; 45(4): 450-458, 2020 04.
Article in English | MEDLINE | ID: mdl-31532699

ABSTRACT

Purpose: Corneal collagen crosslinking (CXL) through an intact epithelium (epi-on) at high irradiance could potentially improve patient comfort, visual recovery, and clinical workflow compared to conventional epi-off CXL. However, intact epithelium limits stromal delivery of the oxygen, photosensitizer, and ultraviolet-A (UV-A) radiation needed to drive CXL. This ex vivo study evaluated three different epi-on CXL protocols compared to positive and negative controls, specifically focusing on the impact of supplemental oxygen. Endpoints included stromal oxygen levels, stiffness of crosslinked tissue, and acute flattening of whole eyes.Materials & Methods: Ex vivo porcine eyes were held in a custom environmental chamber. Intrastromal oxygen levels were continuously measured before, during, and after UV illumination by a fiberoptic probe inserted into a laser-cut flap. Accelerated, high irradiance, epi-on CXL protocols using riboflavin formulated with benzalkonium chloride (BAC) were studied, with and without supplemental oxygen. These were compared to an alternate, low irradiance, epi-on protocol using riboflavin formulated with sodium iodide. Both negative (no CXL) and positive (epi-off modified Dresden protocol) controls were performed. Post-CXL elastic modulus was measured using extensiometry and anterior tangential curvature was measured using a Scheimpflug tomographer.Results: Protocols including supplemental oxygen resulted in an approximately 5-fold increase in stromal oxygen levels prior to CXL. During epi-on, high-irradiance UV-A delivery under hyperoxic conditions, an aerobic state was maintained. Conversely, under normoxic conditions, stromal oxygen rapidly depleted to 0-5% for all other protocols. The combination of supplemental oxygen, BAC formulation, and high-irradiance UV-A resulted in the largest biomechanical changes and most pronounced flattening effects of the three epi-on protocols.Conclusions: Ex vivo analysis of stromal oxygen levels, corneal stiffness, and acute anterior curvature change indicates that simultaneous optimization of the oxygen environment, riboflavin formulation, and UV-A protocol can significantly increase the effects of corneal collagen crosslinking.


Subject(s)
Collagen/pharmacology , Corneal Stroma/metabolism , Cross-Linking Reagents/pharmacology , Keratoconus/metabolism , Oxygen/metabolism , Photochemotherapy/methods , Riboflavin/pharmacology , Animals , Corneal Stroma/diagnostic imaging , Corneal Topography , Disease Models, Animal , Keratoconus/diagnosis , Keratoconus/drug therapy , Photosensitizing Agents/pharmacology , Swine , Ultraviolet Rays
3.
Biomed Opt Express ; 3(10): 2647-57, 2012 Oct 01.
Article in English | MEDLINE | ID: mdl-23082303

ABSTRACT

We present a 1300 nm Fourier domain mode locked (FDML) laser for optical coherence tomography (OCT) that combines both, a high 1.6 MHz wavelength sweep rate and an ultra-long instantaneous coherence length for rapid volumetric deep field imaging. By reducing the dispersion in the fiber delay line of the FDML laser, the instantaneous coherence length and hence the available imaging range is approximately quadrupled compared to previously published MHz-FDML setups, the imaging speed is increased by a factor of 16 compared to previous extended coherence length results. We present a detailed characterization of the FDML laser performance. We demonstrate for the first time MHz-OCT imaging of the anterior segment of the human eye. The OCT system provides enough imaging depth to cover the whole range from the top surface of the cornea down to the crystalline lens.

4.
Gastrointest Endosc ; 76(6): 1104-12, 2012 Dec.
Article in English | MEDLINE | ID: mdl-22831857

ABSTRACT

BACKGROUND: Radiofrequency ablation (RFA) is effective for treating Barrett's esophagus (BE) but often involves multiple endoscopy sessions over several months to achieve complete response. OBJECTIVE: Identify structural markers that correlate with treatment response by using 3-dimensional (3-D) optical coherence tomography (OCT; 3-D OCT). DESIGN: Cross-sectional. SETTING: Single teaching hospital. PATIENTS: Thirty-three patients, 32 male and 1 female, with short-segment (<3 cm) BE undergoing RFA treatment. INTERVENTION: Patients were treated with focal RFA, and 3-D OCT was performed at the gastroesophageal junction before and immediately after the RFA treatment. Patients were re-examined with standard endoscopy 6 to 8 weeks later and had biopsies to rule out BE if not visibly evident. MAIN OUTCOME MEASUREMENTS: The thickness of BE epithelium before RFA and the presence of residual gland-like structures immediately after RFA were determined by using 3-D OCT. The presence of BE at follow-up was assessed endoscopically. RESULTS: BE mucosa was significantly thinner in patients who achieved complete eradication of intestinal metaplasia than in patients who did not achieve complete eradication of intestinal metaplasia at follow-up (257 ± 60 µm vs 403 ± 86 µm; P < .0001). A threshold thickness of 333 µm derived from receiver operating characteristic curves corresponded to a 92.3% sensitivity, 85% specificity, and 87.9% accuracy in predicting the presence of BE at follow-up. The presence of OCT-visible glands immediately after RFA also correlated with the presence of residual BE at follow-up (83.3% sensitivity, 95% specificity, 90.6% accuracy). LIMITATIONS: Single center, cross-sectional study in which only patients with short-segment BE were examined. CONCLUSION: Three-dimensional OCT assessment of BE thickness and residual glands during RFA sessions correlated with treatment response. Three-dimensional OCT may predict responses to RFA or aid in making real-time RFA retreatment decisions in the future.


Subject(s)
Barrett Esophagus/surgery , Catheter Ablation , Esophagoscopy , Esophagus/pathology , Tomography, Optical Coherence/methods , Adult , Aged , Aged, 80 and over , Barrett Esophagus/pathology , Cross-Sectional Studies , Esophagus/surgery , Female , Follow-Up Studies , Humans , Imaging, Three-Dimensional , Male , Middle Aged , Sensitivity and Specificity , Treatment Outcome
5.
Gastroenterol Res Pract ; 2012: 684832, 2012.
Article in English | MEDLINE | ID: mdl-22844274

ABSTRACT

Two main nonsurgical endoscopic approaches for ablating dysplastic and early cancer lesions in the esophagus have gained popularity, namely, radiofrequency ablation (RFA) and cryospray ablation (CSA). We report a uniquely suited endoscopic and near-microscopic imaging modality, three-dimensional (3D) optical coherence tomography (OCT), to assess and compare the esophagus immediately after RFA and CSA. The maximum depths of architectural changes were measured and compared between the two treatment groups. RFA was observed to induce 230~260 µm depth of architectural changes after each set of ablations over a particular region, while CSA was observed to induce edema-like spongiform changes to ~640 µm depth within the ablated field. The ability to obtain micron-scale depth-resolved images of tissue structural changes following different ablation therapies makes 3D-OCT an ideal tool to assess treatment efficacy. Such information could be potentially used to provide real-time feedback for treatment dosing and to identify regions that need further retreatment.

6.
World J Gastroenterol ; 18(20): 2502-10, 2012 May 28.
Article in English | MEDLINE | ID: mdl-22654447

ABSTRACT

AIM: To demonstrate the feasibility of optical coherence tomography (OCT) imaging in differentiating cervical inlet patch (CIP) from normal esophagus, Barrett's esophagus (BE), normal stomach and duodenum. METHODS: This study was conducted at the Veterans Affairs Boston Healthcare System (VABHS). Patients undergoing standard esophagogastroduodenoscopy at VABHS, including one patient with CIP, one representative patient with BE and three representative normal subjects were included. White light video endoscopy was performed and endoscopic 3D-OCT images were obtained in each patient using a prototype OCT system. The OCT imaging probe passes through the working channel of the endoscope to enable simultaneous video endoscopy and 3D-OCT examination of the human gastrointestinal (GI) tract. Standard hematoxylin and eosin (H and E) histology was performed on biopsy or endoscopic mucosal resection specimens in order to compare and validate the 3D-OCT data. RESULTS: CIP was observed from a 68-year old male with gastroesophageal reflux disease. The CIP region appeared as a pink circular lesion in the upper esophagus under white light endoscopy. OCT imaging over the CIP region showed columnar epithelium structure, which clearly contrasted the squamous epithelium structure from adjacent normal esophagus. 3D-OCT images obtained from other representative patients demonstrated distinctive patterns of the normal esophagus, BE, normal stomach, and normal duodenum bulb. Microstructures, such as squamous epithelium, lamina propria, muscularis mucosa, muscularis propria, esophageal glands, Barrett's glands, gastric mucosa, gastric glands, and intestinal mucosal villi were clearly observed with OCT and matched with H and E histology. These results demonstrated the feasibility of using OCT to evaluate GI tissue morphology in situ and in real-time. CONCLUSION: We demonstrate in situ evaluation of CIP microstructures using 3D-OCT, which may be a useful tool for future diagnosis and follow-up of patients with CIP.


Subject(s)
Esophageal Diseases/pathology , Tomography, Optical Coherence , Aged , Barrett Esophagus/pathology , Duodenum/anatomy & histology , Endoscopy, Digestive System , Esophagus/anatomy & histology , Humans , Male , Stomach/anatomy & histology
7.
Gastrointest Endosc ; 76(1): 32-40, 2012 Jul.
Article in English | MEDLINE | ID: mdl-22482920

ABSTRACT

BACKGROUND: Radiofrequency ablation (RFA) is an endoscopic technique used to eradicate Barrett's esophagus (BE). However, such ablation can commonly lead to neosquamous epithelium overlying residual BE glands not visible by conventional endoscopy and may evade detection on random biopsy samples. OBJECTIVE: To demonstrate the capability of endoscopic 3-dimensional optical coherence tomography (3D-OCT) for the identification and characterization of buried glands before and after RFA therapy. DESIGN: Cross-sectional study. SETTING: Single teaching hospital. PATIENTS: Twenty-six male and 1 female white patients with BE undergoing RFA treatment. INTERVENTIONS: 3D-OCT was performed at the gastroesophageal junction in 18 patients before attaining complete eradication of intestinal metaplasia (pre-CE-IM group) and in 16 patients after CE-IM (post-CE-IM group). MAIN OUTCOME MEASUREMENTS: Prevalence, size, and location of buried glands relative to the squamocolumnar junction. RESULTS: 3D-OCT provided an approximately 30 to 60 times larger field of view compared with jumbo and standard biopsy and sufficient imaging depth for detecting buried glands. Based on 3D-OCT results, buried glands were found in 72% of patients (13/18) in the pre-CE-IM group and 63% of patients (10/16) in the post-CE-IM group. The number (mean [standard deviation]) of buried glands per patient in the post-CE-IM group (7.1 [9.3]) was significantly lower compared with the pre-CE-IM group (34.4 [44.6]; P = .02). The buried gland size (P = .69) and distribution (P = .54) were not significantly different before and after CE-IM. LIMITATIONS: A single-center, cross-sectional study comparing patients at different time points in treatment. Lack of 1-to-1 coregistered histology for all OCT data sets obtained in vivo. CONCLUSION: Buried glands were frequently detected with 3D-OCT near the gastroesophageal junction before and after radiofrequency ablation.


Subject(s)
Barrett Esophagus/pathology , Esophagogastric Junction/pathology , Tomography, Optical Coherence , Adult , Aged , Aged, 80 and over , Barrett Esophagus/surgery , Catheter Ablation , Cross-Sectional Studies , Esophagoscopy , Female , Humans , Imaging, Three-Dimensional , Male , Middle Aged
9.
Opt Express ; 19(21): 20930-9, 2011 Oct 10.
Article in English | MEDLINE | ID: mdl-21997102

ABSTRACT

Fourier domain mode locked (FDML) lasers are excellent tunable laser sources for frequency domain optical coherence tomography (FD-OCT) systems due to their combination of high sweep rates, large tuning ranges, and high output powers. However, conventional FDML lasers provide coherence lengths of only 4-10 mm, limiting their use in demanding applications such as intravascular OCT where coherence lengths of >20 mm are required for optimal imaging of large blood vessels. Furthermore, like most swept lasers, conventional FDML lasers produce only one useable sweep direction per tunable filter drive cycle, halving the effective sweep rate of the laser compared to the filter drive frequency. Here, we demonstrate a new class of FDML laser incorporating broadband dispersion compensation near 1310 nm. Elimination of chromatic dispersion in the FDML cavity results in the generation of forward (short to long wavelength) and backward (long to short wavelength) sweeps with substantially identical properties and coherence lengths of >21 mm. This advance enables long-range, high-speed FD-OCT imaging without the need for optical buffering stages, significantly reducing laser cost and complexity.


Subject(s)
Fourier Analysis , Optics and Photonics/methods , Tomography, Optical Coherence/methods , Algorithms , Biotechnology/methods , Diagnostic Imaging/methods , Equipment Design , Lasers , Models, Statistical , Optical Fibers , Semiconductors , Tomography, Optical Coherence/instrumentation
10.
Opt Lett ; 35(5): 700-2, 2010 Mar 01.
Article in English | MEDLINE | ID: mdl-20195324

ABSTRACT

We demonstrate photothermal optical coherence tomography (OCT) imaging in highly scattering human breast tissue ex vivo. A 120 kHz axial scan rate, swept-source phase-sensitive OCT system at 1300 nm was used to detect phase changes induced by 830 nm photothermal excitation of gold nanoshells. Localized phase modulation was observed 300-600 microm deep in scattering tissue using an excitation power of only 22 mW at modulation frequencies up to 20 kHz. This technique enables integrated structural and molecular-targeted imaging for cancer markers using nanoshells.


Subject(s)
Breast/cytology , Contrast Media/chemistry , Gold , Molecular Probe Techniques , Nanoparticles , Tomography, Optical Coherence/methods , Female , Gold/chemistry , Hot Temperature , Humans , In Vitro Techniques , Nanoparticles/chemistry , Reproducibility of Results , Sensitivity and Specificity
11.
Opt Express ; 17(23): 21257-70, 2009 Nov 09.
Article in English | MEDLINE | ID: mdl-19997365

ABSTRACT

We demonstrate a frequency comb (FC) swept laser and a frequency comb Fourier domain mode locked (FC-FDML) laser for applications in optical coherence tomography (OCT). The fiber-based FC swept lasers operate at a sweep rate of 1kHz and 120kHz, respectively over a 135nm tuning range centered at 1310nm with average output powers of 50mW. A 25GHz free spectral range frequency comb filter in the swept lasers causes the lasers to generate a series of well defined frequency steps. The narrow bandwidth (0.015nm) of the frequency comb filter enables a approximately -1.2dB sensitivity roll off over approximately 3mm range, compared to conventional swept source and FDML lasers which have -10dB and -5dB roll offs, respectively. Measurements at very long ranges are possible with minimal sensitivity loss, however reflections from outside the principal measurement range of 0-3mm appear aliased back into the principal range. In addition, the frequency comb output from the lasers are equally spaced in frequency (linear in k-space). The filtered laser output can be used to self-clock the OCT interference signal sampling, enabling direct fast Fourier transformation of the fringe signals, without the need for fringe recalibration procedures. The design and operation principles of FC swept lasers are discussed and designs for short cavity lasers for OCT and interferometric measurement applications are proposed.


Subject(s)
Lasers , Tomography, Optical Coherence/instrumentation , Computer-Aided Design/instrumentation , Equipment Design , Fourier Analysis , Interferometry/methods , Optical Fibers , Optics and Photonics , Reproducibility of Results , Sensitivity and Specificity , Time Factors , Tomography, Optical Coherence/methods
12.
Opt Express ; 17(2): 784-96, 2009 Jan 19.
Article in English | MEDLINE | ID: mdl-19158891

ABSTRACT

Three-dimensional (3D) endomicroscopy imaging of the human gastrointestinal tract is demonstrated in vivo using a swept source optical coherence tomography (OCT) system. 3D datasets of normal and pathologic regions of the colon, rectum, and anal verge were obtained from seven volunteers undergoing diagnostic or therapeutic colonoscopy. 3D-OCT enables high resolution endomicroscopy examination through visualization of tissue architectural morphology using virtual cross-sectional images with arbitrary orientations as well as en face projection images. Axial image resolutions of 6 mum in tissue are obtained over a approximately 180 mm2 field with an imaging range of 1.6 mm. A Fourier domain mode locked (FDML) laser providing a tuning range of 180 nm at a sweep rate of 62 kHz is used as the system light source. This clinical pilot study demonstrates the potential of 3D-OCT for distinguishing normal from pathologic colorectal tissue, assessing endoscopic therapies and healing progression.


Subject(s)
Colon/pathology , Imaging, Three-Dimensional , Microscopy/methods , Tomography, Optical Coherence/methods , Colitis, Ulcerative/diagnosis , Colitis, Ulcerative/pathology , Colonoscopy , Epithelium/pathology , Humans , Male , Proctitis/diagnosis , Proctitis/pathology , Proctitis/therapy
13.
Therap Adv Gastroenterol ; 2(3): 149-156, 2009 Jan 01.
Article in English | MEDLINE | ID: mdl-20593010

ABSTRACT

Endoscopic argon plasma coagulation and bipolar electrocautery are currently preferred treatments for chronic radiation proctitis, but ulcerations and strictures frequently occur. Radiofrequency ablation (RFA) has been successful for mucosal ablation in the esophagus. Here we report the efficacy of RFA with the BarRx Halo(90) system in three patients with bleeding from chronic radiation proctitis. In all cases, the procedure was well tolerated and hemostasis was achieved after 1 or 2 RFA sessions. Re-epithelialization of squamous mucosa was observed over areas of prior hemorrhage. No stricturing or ulceration was seen on follow-up up to 19 months after RFA treatment. Real-time endoscopic optical coherence tomography (EOCT) visualized epithelialization and subsurface tissue microvasculature pre- and post-treatment, demonstrating its potential for follow-up assessment of endoscopic therapies.

14.
Opt Lett ; 33(21): 2556-8, 2008 Nov 01.
Article in English | MEDLINE | ID: mdl-18978919

ABSTRACT

We demonstrate en face swept source optical coherence tomography (ss-OCT) without requiring a Fourier transformation step. The electronic optical coherence tomography (OCT) interference signal from a k-space linear Fourier domain mode-locked laser is mixed with an adjustable local oscillator, yielding the analytic reflectance signal from one image depth for each frequency sweep of the laser. Furthermore, a method for arbitrarily shaping the spectral intensity profile of the laser is presented, without requiring the step of numerical apodization. In combination, these two techniques enable sampling of the in-phase and quadrature signal with a slow analog-to-digital converter and allow for real-time display of en face projections even for highest axial scan rates. Image data generated with this technique is compared to en face images extracted from a three-dimensional OCT data set. This technique can allow for real-time visualization of arbitrarily oriented en face planes for the purpose of alignment, registration, or operator-guided survey scans while simultaneously maintaining the full capability of high-speed volumetric ss-OCT functionality.


Subject(s)
Image Enhancement/instrumentation , Signal Processing, Computer-Assisted/instrumentation , Tomography, Optical Coherence/instrumentation , Computer Systems , Equipment Design , Equipment Failure Analysis , Sensitivity and Specificity
15.
Invest Ophthalmol Vis Sci ; 49(11): 5103-10, 2008 Nov.
Article in English | MEDLINE | ID: mdl-18658089

ABSTRACT

PURPOSE: To demonstrate ultrahigh-speed optical coherence tomography (OCT) imaging of the retina and optic nerve head at 249,000 axial scans per second and a wavelength of 1060 nm. To investigate methods for visualization of the retina, choroid, and optic nerve using high-density sampling enabled by improved imaging speed. METHODS: A swept-source OCT retinal imaging system operating at a speed of 249,000 axial scans per second was developed. Imaging of the retina, choroid, and optic nerve were performed. Display methods such as speckle reduction, slicing along arbitrary planes, en face visualization of reflectance from specific retinal layers, and image compounding were investigated. RESULTS: High-definition and three-dimensional (3D) imaging of the normal retina and optic nerve head were performed. Increased light penetration at 1060 nm enabled improved visualization of the choroid, lamina cribrosa, and sclera. OCT fundus images and 3D visualizations were generated with higher pixel density and less motion artifacts than standard spectral/Fourier domain OCT. En face images enabled visualization of the porous structure of the lamina cribrosa, nerve fiber layer, choroid, photoreceptors, RPE, and capillaries of the inner retina. CONCLUSIONS: Ultrahigh-speed OCT imaging of the retina and optic nerve head at 249,000 axial scans per second is possible. The improvement of approximately 5 to 10x in imaging speed over commercial spectral/Fourier domain OCT technology enables higher density raster scan protocols and improved performance of en face visualization methods. The combination of the longer wavelength and ultrahigh imaging speed enables excellent visualization of the choroid, sclera, and lamina cribrosa.


Subject(s)
Imaging, Three-Dimensional/methods , Optic Nerve/cytology , Retina/cytology , Tomography, Optical Coherence/methods , Equipment Design , Humans , Reproducibility of Results , Tomography, Optical Coherence/instrumentation
16.
Opt Express ; 16(7): 4376-93, 2008 Mar 31.
Article in English | MEDLINE | ID: mdl-18542535

ABSTRACT

The detection of a gold nanoparticle contrast agent is demonstrated using a photothermal modulation technique and phase sensitive optical coherence tomography (OCT). A focused beam from a laser diode at 808 nm is modulated at frequencies of 500 Hz-60 kHz while irradiating a solution containing nanoshells. Because the nanoshells are designed to have a high absorption coefficient at 808 nm, the laser beam induces small-scale localized temperature oscillations at the modulation frequency. These temperature oscillations result in optical path length changes that are detected by a phase-sensitive, swept source OCT system. The OCT system uses a double-buffered Fourier domain mode locked (FDML) laser operating at a center wavelength of 1315 nm and a sweep rate of 240 kHz. High contrast is observed between phantoms containing nanoshells and phantoms without nanoshells. This technique represents a new method for detecting gold nanoparticle contrast agents with excellent signal-to-noise performance at high speeds using OCT.


Subject(s)
Gold , Image Enhancement/methods , Lasers , Nanoparticles/ultrastructure , Tomography, Optical Coherence/methods , Gold/analysis , Phantoms, Imaging , Reproducibility of Results , Sensitivity and Specificity , Temperature , Tomography, Optical Coherence/instrumentation
17.
Lab Invest ; 88(4): 441-9, 2008 Apr.
Article in English | MEDLINE | ID: mdl-18268476

ABSTRACT

Optical coherence tomography (OCT) is a rapidly emerging imaging modality that can provide non-invasive, cross-sectional, high-resolution images of tissue morphology in situ and in real-time. In the present series of studies, we used a high-speed OCT imaging system equipped with a frequency-swept laser light source (1.3 mum wavelength) to study living kidneys in situ. Adult, male Munich-Wistar rats were anesthetized, a laparotomy was performed and the living kidneys were exposed for in situ observation. We observed the kidneys prior to, during and following exposure to renal ischemia induced by clamping the renal artery. The effects of intravenous mannitol infusion (1.0 ml of 25%) prior to and during renal ischemia were also studied. Finally, living kidneys were flushed with a renal preservation solution, excised and observed while being stored at 0-4 degrees C. Three-dimensional OCT data sets enabled visualization of the morphology of the uriniferous tubules and the renal corpuscles. When renal ischemia was induced, OCT revealed dramatic shrinkage of tubular lumens due to swelling of the lining epithelium. Three-dimensional visualization and volumetric rendering software provided an accurate evaluation of volumetric changes in tubular lumens in response to renal ischemia. Observations of kidneys flushed with a renal preservation solution and stored at 0-4 degrees C also revealed progressive and significant loss of tubular integrity over time. Intravenous infusion of mannitol solution resulted in thinning of the tubular walls and an increase in the tubular lumen diameters. Mannitol infusion also prevented the cell swelling that otherwise resulted in shrinkage of proximal tubule lumens during ischemia. We conclude that OCT represents an exciting new approach to visualize, in real-time, pathological changes in the living kidney in a non-invasive fashion. Possible clinical applications are discussed.


Subject(s)
Kidney/pathology , Tomography, Optical Coherence , Animals , Ischemia/pathology , Kidney/blood supply , Kidney/drug effects , Kidney Transplantation , Male , Mannitol/pharmacology , Organ Preservation , Rats , Rats, Wistar
18.
Opt Lett ; 32(6): 626-8, 2007 Mar 15.
Article in English | MEDLINE | ID: mdl-17308582

ABSTRACT

Buffered Fourier domain mode-locked (FDML) lasers are demonstrated for dynamic phase-sensitive optical coherence tomography (OCT) and 3D OCT phase microscopy. Systems are operated at sweep speeds of 42, 117, and 370 kHz, and displacement sensitivities of 39, 52, and 102 pm are achieved, respectively. Sensitivities are comparable to spectrometer-based OCT phase microscopy systems, but much faster acquisition speeds are possible. An additional factor of sqrt 2 improvement in noise performance is observed for differential phase measurements, which is important for Doppler OCT. Dynamic measurements of piezoelectric transducer motion and static 3D OCT phase microscopy are demonstrated. Buffered FDML lasers provide excellent displacement sensitivities at extremely high sweep speeds.


Subject(s)
Image Enhancement/instrumentation , Imaging, Three-Dimensional/instrumentation , Lasers , Microscopy, Phase-Contrast/instrumentation , Tomography, Optical Coherence/instrumentation , Equipment Design , Equipment Failure Analysis , Fourier Analysis , Image Interpretation, Computer-Assisted/instrumentation , Image Interpretation, Computer-Assisted/methods , Reproducibility of Results , Sensitivity and Specificity
19.
Opt Express ; 15(10): 6210-7, 2007 May 14.
Article in English | MEDLINE | ID: mdl-19546926

ABSTRACT

Swept source optical coherence microscopy (OCM) enables cellular resolution en face imaging as well as integration with optical coherence tomography (OCT) cross sectional imaging. A buffered Fourier domain mode-locked (FDML) laser light source provides high speed, three dimensional imaging. Image resolutions of 1.6 microm x 8 microm (transverse x axial) with a 220 microm x 220 microm field of view and sensitivity higher than 98 dB are achieved. Three dimensional cellular imaging is demonstrated in vivo in the Xenopus laevis tadpole and ex vivo in the rat kidney and human colon.

20.
Opt Express ; 15(24): 15972-86, 2007 Nov 26.
Article in English | MEDLINE | ID: mdl-19550884

ABSTRACT

Gold punchwork and underdrawing in Renaissance panel paintings are analyzed using both three-dimensional swept source / Fourier domain optical coherence tomography (3D-OCT) and high resolution digital photography. 3D-OCT can generate en face images with micrometer-scale resolutions at arbitrary sectioning depths, rejecting out-of-plane light by coherence gating. Therefore 3D-OCT is well suited for analyzing artwork where a surface layer obscures details of interest. 3D-OCT also enables cross-sectional imaging and quantitative measurement of 3D features such as punch depth, which is beneficial for analyzing the tools and techniques used to create works of art. High volumetric imaging speeds are enabled by the use of a Fourier domain mode locked (FDML) laser as the 3D-OCT light source. High resolution infrared (IR) digital photography is shown to be particularly useful for the analysis of underdrawing, where the materials used for the underdrawing and paint layers have significantly different IR absrption properties. In general, 3D-OCT provides a more flexible and comprehensive analysis of artwork than high resolution photography, but also requires more complex instrumentation and data analysis.