Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Expert Rev Med Devices ; : 1-10, 2024 Aug 01.
Article in English | MEDLINE | ID: mdl-39087797

ABSTRACT

INTRODUCTION: Cardiogenic shock (CS) is a complex life-threatening condition that results from primary cardiac dysfunction, leading to persistent hypotension and systemic hypoperfusion. Among the therapeutic options for CS are various percutaneous mechanical circulatory support (MCS) devices that have emerged as an increasingly effective hemodynamic support option. Percutaneous therapies can act as short-term mechanical circulatory assistance and can be split into intra-aortic balloon pump (IABP) and non-IABP percutaneous mechanical devices. AREAS COVERED: This review will evaluate the MCS value while considering the mortality rate improvements. We also aim to outline the function of pharmacotherapies and percutaneous hemodynamic MCS devices in managing CS patients to avoid the onset of end-organ dysfunction and improve both early and late outcomes. EXPERT OPINION: Given the complexity, acuity and high mortality associated with CS, and despite the availability and efficacy of pharmacological management, MCS is required to achieve hemodynamic stability and improve survival. Various percutaneous MCS devices are available with varying indications and clinical outcomes. The rates of early mortality and complications were found to be comparable between the four devices, yet, IABP seemed to show the most optimal clinical profile whilst ECMO demonstrated its more long-term efficacy.

2.
Expert Rev Med Devices ; 21(3): 165-177, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38431273

ABSTRACT

INTRODUCTION: With the incidence of thoracic aortic disease on the rise, total arch replacement (TAR) with frozen elephant trunk (FET) remains the gold-standard management strategy due to optimal results. Several FET devices exist commercially on the global market. However, the mainstay and most commonly used and reported device is the Thoraflex Hybrid Prosthesis (THP), with several recent reports suggesting its superiority. AREAS COVERED: This review aims to collate and summarize the evidence in the literature on the clinical outcomes of TAR with FET using THP, with a focus on mortality, neurological complications, endoleak, distal stent-induced new entry (dSINE), aortic remodeling, coagulopathy, and graft kinking. In addition, the design features of THP is discussed, and an overview of market competitors is also highlighted. EXPERT OPINION: THP consistently demonstrates its effectiveness in treating complex thoracic aortic pathology through favorable clinical outcomes, which can be attributed to its unique and innovative design. Rates of early mortality ranged 0.6-14.2%, neurological complications 0-25%, endoleak 0-8.4% and dSINE 0-14.5%, with minimal incidence of graft kinking and coagulopathy. Aortic remodeling is favorable and comparable to competitors. All this evidence solidifies THP as the leading FET device, particularly when combined with appropriate patient selection and surgical planning.


Subject(s)
Aortic Dissection , Blood Vessel Prosthesis Implantation , Humans , Blood Vessel Prosthesis , Endoleak/surgery , Stents , Aorta, Thoracic/surgery , Retrospective Studies , Treatment Outcome
3.
Cardiovasc Diagn Ther ; 13(6): 1104-1117, 2023 Dec 15.
Article in English | MEDLINE | ID: mdl-38162110

ABSTRACT

Background and Objective: The frozen elephant trunk (FET) allows a single-stage repair of complex arch pathologies due to its stented and non-stented hybrid prosthesis (HP) features. FET inherently has its own related complications including distal stent graft-induced new entry (dSINE), failure of aortic remodelling, endoleak, reintervention, and kinking of the stent. The aim of this narrative review is to discuss the latest evidence regarding the postoperative clinical outcomes of the FET procedure. Another aim is to provide an overview of results achieved using different FET devices on the global arch prostheses market. Methods: A comprehensive literature search was conducted using multiple electronic databases to identify and extract the relevant data and information. Key Content and Findings: This review found that the literature reported a 5-12% mortality rate post-FET, with varying figures depending on the prosthesis type. Between 0-18.2% of patients developed dSINE, while 0.1-28% developed endoleak. Reintervention occurred in 0-28% of patients and the incidence of kinking has been quoted between 0-8% in the literature. Reporting aortic remodelling rates was challenging due to the lack of standardisation and various measurements reported; however, all studies included in this review reported relative increase in true lumen diameter, reduction in the false lumen diameter, and/or false lumen thrombosis. Conclusions: In conclusion, FET can achieve a favourable postoperative profile in terms of survival, complications and aortic remodelling, and remains the gold-standard treatment for thoracic aortic pathologies implicating the arch and descending thoracic aorta.

SELECTION OF CITATIONS
SEARCH DETAIL