Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 15 de 15
Filter
Add more filters










Publication year range
1.
Iran J Vet Res ; 21(3): 226-229, 2020.
Article in English | MEDLINE | ID: mdl-33178302

ABSTRACT

BACKGROUND: Acute-phase proteins (APPs) may be increased due to different stresses during estrus phase in farm animals. AIMS: Determining changes of APPs at different phases of non-synchronized estrous cycle group (NSEG), and Ovsynch-synchronized estrous cycle group (SEG) in Holstein cows. METHODS: Twelve non-pregnant clinically and paraclinicaly healthy Holstein cows with a body condition score (BCS) of 2.75 and 70 days in milk were chosen. Two groups including NSEG and SEG were performed. Blood sampling was carried out from NSEG at the time of diestrus, proestrus, and estrus. In SEG, blood sampling was performed on day 7 (at the time of prostaglandin injection, equivalent diestrus), day 9 (at the time of gonadotropin-releasing hormone (GnRH) injection, equivalent proestrus), and day 10 (at the time of insemination, equivalent estrus) of synchronization protocol. Concentrations of haptoglobin (Hp), serum amyloid A (SAA), ceruloplasmin (Cp), and fibrinogen (Fib) were measured. RESULTS: Concentration of Hp at estrus phase was significantly higher compared with diestrus (P=0.001) and proestrus (P=0.019) in NSEG. Moreover, Hp level in the NSEG was significantly higher than SEG at estrus phase (P=0.002). Concentrations of SAA, Cp, and Fib had no significant differences during various phases of estrous cycle in each group or between equivalent phases of both groups. CONCLUSION: It seems that unlike SAA, Fib, and Cp, concentrations of Hp may be affected by different phases of estrous cycle. Although APPs are not specific indicators, their changes besides other clinical and paraclinical indices may be helpful for more accurate heat detection in dairy cows.

2.
J Biomed Phys Eng ; 8(1): 133-140, 2018 Mar.
Article in English | MEDLINE | ID: mdl-29732348

ABSTRACT

Radiation damage is to a large extent caused by overproduction of reactive oxygen species (ROS). Radioprotectors are agents or substances that reduce the effects of radiation in healthy normal tissues while maintaining the sensitivity to radiation damage in tumor cells. Radioprotectors are agents or substances that reduce the effects of radiation in healthy normal tissues while maintaining the sensitivity to radiation damage in tumor cells Cimetidine was found more effective when used in vivo; this effect might be due to the augmentation of the presence of Sulphur atom in the compound which is ýimportant for their scavenging activity. Recently, a new herbal-based medicine with immunomodulatory capacities, Setarud (IMOD), was introduced as an additional therapy in various inflammatory diseases and HIV infection. IMOD is a mixture of herbal extracts enriched with selenium. Selenium confers protection by inducing or activating cellular free-radical scavenging systems and by enhancing peroxide breakdown. This article suggests that nontoxic amount of IMOD and cimetidine have radioprotective properties and could reduce cytotoxic effects of radiation.

3.
Phys Med Biol ; 62(18): 7394-7406, 2017 Sep 01.
Article in English | MEDLINE | ID: mdl-28632500

ABSTRACT

An important challenge in real-world biomedical applications of x-ray phase contrast imaging (XPCI) techniques is the efficient use of the photon flux generated by an incoherent and polychromatic x-ray source. This efficiency can directly influence dose and exposure time and ideally should not affect the superior contrast and sensitivity of XPCI. In this paper, we present a quantitative evaluation of the photon detection efficiency of two laboratory-based XPCI methods, grating interferometry (GI) and coded-aperture (CA). We adopt a Monte Carlo approach to simulate existing prototypes of those systems, tailored for mammography applications. Our simulations were validated by means of a simple experiment performed on a CA XPCI system. Our results show that the fraction of detected photons in the standard energy range of mammography are about 1.4% and 10% for the GI and CA techniques, respectively. The simulations indicate that the design of the optical components plays an important role in the higher efficiency of CA compared to the GI method. It is shown that the use of lower absorbing materials as the substrates for GI gratings can improve its flux efficiency by up to four times. Along similar lines, we also show that an optimized and compact configuration of GI could lead to a 3.5 times higher fraction of detected counts compared to a standard and non-optimised GI implementation.


Subject(s)
Breast/diagnostic imaging , Interferometry/methods , Mammography/instrumentation , Monte Carlo Method , Photons , Radiographic Image Interpretation, Computer-Assisted/instrumentation , X-Ray Diffraction/instrumentation , Female , Humans , Microscopy, Phase-Contrast
4.
J Environ Radioact ; 151 Pt 1: 75-81, 2016 Jan.
Article in English | MEDLINE | ID: mdl-26440697

ABSTRACT

The discrimination of the composition of environmental and non-environmental materials by the estimation of the (234)U/(238)U activity ratio in alpha-particle spectrometry is important in many applications. If the interfering elements are not completely separated from the uranium, they can interfere with the determination of (234)U. Thickness as a result of the existence of iron in the source preparation phase and their alpha lines can broaden the alpha line of (234)U in alpha spectra. Therefore, the asymmetric broadening of the alpha line of (234)U and overlapping of peaks make the analysis of the alpha particle spectra and the interpretation of the results difficult. Applying Artificial Neural Network (ANN) to a spectrometry system is a good idea because it eliminates limitations of classical approaches by extracting the desired information from the input data. In this work, the average of a partial uranium raw spectrum, were considered. Each point that its slope was of the order of 0-1% per 10 channels, was used as input to the multi-layer feed forward error-back propagation network. The network was trained by an alpha spectrum library which has been developed in the present work. The training data in this study was actual spectral data with any reasonable thickness and interfering elements. According to the results, the method applied to estimate the activity ratio in this work, can examine the alpha spectrum for peaks which would not be expected for a source of given element and provide the clues about composition of uranium contamination in the environmental samples in a fast screening and classifying procedures.


Subject(s)
Radiation Monitoring/methods , Soil Pollutants, Radioactive/analysis , Uranium/analysis , Alpha Particles , Neural Networks, Computer , Regression Analysis , Spectrum Analysis
5.
J Biomed Phys Eng ; 6(4): 220-234, 2016 Dec.
Article in English | MEDLINE | ID: mdl-28144591

ABSTRACT

BACKGROUND: Much research has widely been conducted into thyroid hormones levels following radiotherapy for breast cancer. Consequently, in this study, we evaluated to relate the rate of thyroid hormones levels with the dose distribution among breast cancer patients. MATERIAL AND METHODS: Thirty patients were treated with 4-field breast cancer radiotherapy. The dose volume histograms, the volume percentage of the thyroid absorbing respectively 20, 30, 40 and 50 Gy were then estimated (V20, V30, V40 and V50) together with the individual average thyroid dose over the whole gland derived from their computed tomography-based treatment plans. Then, in serum samples triiodothyronine [T3], thyroxine [T4], thyroid-stimulating hormone [TSH] of the patients were measured before and after radiotherapy. RESULTS: There were no significant differences in thyroid hormones levels before and after radiotherapy for patients with breast cancer (P value >.05). CONCLUSION: On the balance, we understood that thyroid stimulating hormones levels did not change before and after cancer breast radiotherapy.

6.
J Biomed Phys Eng ; 6(4): 229-234, 2016 Dec.
Article in English | MEDLINE | ID: mdl-28144592

ABSTRACT

BACKGROUND: Much research has widely been conducted into thyroid hormones levels following radiotherapy for breast cancer. Consequently, in this study, we evaluated to relate the rate of thyroid hormones levels with the dose distribution among breast cancer patients. MATERIAL AND METHODS: Thirty patients were treated with 4-field breast cancer radiotherapy. The dose volume histograms, the volume percentage of the thyroid absorbing respectively 20, 30, 40 and 50 Gy were then estimated (V20, V30, V40 and V50) together with the individual average thyroid dose over the whole gland derived from their computed tomography-based treatment plans. Then, in serum samples triiodothyronine [T3], thyroxine [T4], thyroid-stimulating hormone [TSH] of the patients were measured before and after radiotherapy. RESULTS: There were no significant differences in thyroid hormones levels before and after radiotherapy for patients with breast cancer (P value >.05). CONCLUSION: On the balance, we understood that thyroid stimulating hormones levels did not change before and after cancer breast radiotherapy.

7.
Reprod Domest Anim ; 49(2): 233-8, 2014 Apr.
Article in English | MEDLINE | ID: mdl-24325777

ABSTRACT

Post-partum period has an important role in cows' breeding due to its effects on reproductive efficiency and subsequent pregnancy. Escherichia coli, Trueperella pyogenes (Arcanobacterium pyogenes), Fusobacterium necrophorum and Prevotella melaninogenicus are recognized as major pathogens associated with uterine endometrial lesions. The objective of this study was to identify these pathogens using the polymerase chain reaction (PCR) as a culture-independent sensitive method. A total of 172 cows were examined 25-35 days post-partum, and 128 cows were examined at 2 weeks later (39-49 days post-partum). Uterine discharges were collected by covered plastic infusion pipettes. The prevalence of endometritis was greater in the first examination than the second (35.5% vs. 16%). E. coli was detected in eight of the samples, T. pyogenes was detected in 13 of the samples and F. necrophorum was detected in 11 of the samples. There was no positive sample of P. melaninogenicus. Uterine contamination by T. pyogenes and F. necrophorum in the first examination was higher than the second examination. T. pyogenes affected as a tendency the prevalence of clinical endometritis in first examination. Primiparous cows showed 4.02 times higher odds of clinical endometritis compared with second-parity cows in first examination. A multiplex PCR protocol as a simple, less expensive, fast assay was introduced to identify E. coli, T. pyogenes and F. necrophorum.


Subject(s)
Bacteria/classification , Bacterial Infections/veterinary , Cattle Diseases/microbiology , Endometritis/veterinary , Multiplex Polymerase Chain Reaction/veterinary , Animals , Bacteria/genetics , Bacterial Infections/microbiology , Cattle , Dairying , Endometritis/microbiology , Female , Multiplex Polymerase Chain Reaction/methods , Pregnancy
8.
J Mech Behav Biomed Mater ; 21: 32-6, 2013 May.
Article in English | MEDLINE | ID: mdl-23454366

ABSTRACT

The nickel-titanium shape memory alloys have been used in orthodontic application due to their unique properties like superelasticity and biocompatibility. The phase transformation behavior of these alloys can be changed by alloying elements and thermomechanical processing conditions. In this study, two types of NiTi and TiNiCu wires of 0.4mm diameter were produced via thermomechanical treatments with final step of 20% cold drawing followed by annealing at different temperatures of 300 and 400 °C for varying times of 10, 30 and 60 min. The processed wires were characterized by oral cavity configuration three point bending (OCTPB) test at 37 °C to specify the mechanical transformation features. Also, differential scanning calorimetry (DSC) was used to analyze the thermal transformation temperatures of selected wires. The results showed the thermomechanical treatment at 300 °C for 30 min was the suitable process in terms of superelasticity and transformation temperatures for orthodontic application.


Subject(s)
Copper/chemistry , Nickel/chemistry , Orthodontic Wires , Titanium/chemistry , Elastic Modulus , Equipment Failure Analysis , Hot Temperature , Materials Testing , Phase Transition , Prosthesis Design , Stress, Mechanical , Tensile Strength
9.
J Biomed Phys Eng ; 3(4): 123-32, 2013 Dec.
Article in English | MEDLINE | ID: mdl-25505758

ABSTRACT

BACKGROUND AND OBJECTIVE: The most common intravascular brachytherapy sources include (32)P, (188)Re, (106)Rh and (90)Sr/(90)Y. In this research, skin absorbed dose for different covering materials in dealing with these sources were evaluated and the best covering material for skin protection and reduction of absorbed dose by radiation staff was recognized and recommended. METHOD: Four materials including polyethylene, cotton and two different kinds of plastic were proposed as skin covers and skin absorbed dose at different depths for each kind of the materials was calculated separately using the VARSKIN3 code. RESULTS: The results suggested that for all sources, skin absorbed dose was minimized when using polyethylene. Considering this material as skin cover, maximum and minimum doses at skin surface were related to (90)Sr/(90)Y and (106)Rh, respectively. CONCLUSION: polyethylene was found the most effective cover in reducing skin dose and protecting the skin. Furthermore, proper agreement between the results of VARSKIN3 and other experimental measurements indicated that VRASKIN3 is a powerful tool for skin dose calculations when working with beta emitter sources. Therefore, it can be utilized in dealing with the issue of radiation protection.

10.
Radiat Prot Dosimetry ; 154(3): 375-80, 2013.
Article in English | MEDLINE | ID: mdl-23019599

ABSTRACT

Recently, due to space and weight limitations, scientists have tried to design and produce concrete shields with increased attenuation of radiation but not increased mass density. Over the past years, the authors' had focused on the production of heavy concrete for radiation shielding, but this is the first experience of producing intermediate-weight concrete. In this study, ulexite (hydrated sodium calcium borate hydroxide) and galena (lead ore) have been used for the production of a special intermediate-weight concrete. Shielding properties of this intermediate-weight concrete against photons have been investigated by exposing the samples to narrow and broad beams of gamma rays emitted from a 6°Co radiotherapy unit. Densities of the intermediate-weight concrete samples ranged 3.64-3.90 g cm⁻³, based on the proportion of the ulexite in the mix design. The narrow-beam half-value layer (HVL) of the ulexite-galena concrete samples for 1.25 MeV 6°Co gamma rays was 2.84 cm, much less than that of ordinary concrete (6.0 cm). The Monte Carlo (MC) code MCNP4C was also used to model the attenuation of 6°Co gamma-ray photons and Am-Be neutrons of the ulexite-galena concrete with different thicknesses. The 6°Co HVL calculated by MCNP simulation was 2.87 cm, indicating a good agreement between experimental measurements and MC simulation. Furthermore, MC-calculated results showed that thick ulexite-galena concrete shields (60-cm thickness) had a 7.22 times (722 %) greater neutron attenuation compared with ordinary concrete. The intermediate-weight ulexite-galena concrete manufactured in this study may have many important applications in the construction of radiation shields with weight limitations such as the swing or sliding doors that are currently used for radiotherapy treatment rooms.


Subject(s)
Boron Compounds/chemistry , Construction Materials/analysis , Lead/chemistry , Radiation Protection/instrumentation , Radiation Protection/methods , Sulfides/chemistry , Boron Compounds/radiation effects , Construction Materials/radiation effects , Equipment Design , Equipment Failure Analysis , Gamma Rays , Lead/radiation effects , Materials Testing , Specific Gravity , Sulfides/radiation effects
11.
Appl Radiat Isot ; 69(10): 1540-5, 2011 Oct.
Article in English | MEDLINE | ID: mdl-21764592

ABSTRACT

A novel water equivalent formulation of PRESAGE dosimeter more suitable for radiotherapy applications has been introduced and its radiological water equivalency has been investigated. Furthermore, its radiological properties have been compared with an existing PRESAGE formulation over an energy range from 10 to 20 MeV. Monte Carlo simulation method has been implemented to determine and compare depth dose profiles in both of the PRESAGE formulations at two different photon energies (140 KV(P) and 6 MV). The results show that our proposed PRESAGE formulation is more water equivalent than its known formulation especially for low photon energy beams.


Subject(s)
Polyurethanes , Radiotherapy Dosage , Humans , Monte Carlo Method , Radiometry/methods
12.
J Mech Behav Biomed Mater ; 4(3): 298-302, 2011 Apr.
Article in English | MEDLINE | ID: mdl-21316617

ABSTRACT

The shape memory nickel-titanium alloy has been applied in many fields due to its unique thermal and mechanical performance. One of the successful applications of NiTi wires is in orthodontics because of its good characteristics such as low stiffness, high spring back, high stored energy, biocompatibility, superelasticity and shape memory effect. The mechanical properties of wires are paid special attention which results in achieving continuous optimal forces and eventually causing rapid tooth movement without any damage. The behavior of the alloy can be controlled by chemical composition and thermo-mechanical treatment during the manufacturing process. In this study two kinds of commercial superelastic NiTi archwires of 0.41 mm diameter were investigated: Copper NiTi and Highland Metal. The chemical analysis of both wires was estimated by energy dispersive spectroscopy (EDS). It was showed that Copper NiTi wire contained copper and chromium. The two types of wires were exposed to different heat treatment conditions at 400 and 500 °C for 10 and 60 min to compare the behavior of the wires at aged and as-received conditions. Phase transformation temperatures clarified by differential scanning calorimetry (DSC) showed B2 <--> R <--> B19 transformation in Highland Metal wire and B2 <--> B19(') transformation in Copper NiTi wire. Three point bending (TPB) tests in the certain designed fixture were performed at 37 °C to evaluate the mechanical behavior of the wires. The experimental results revealed the superelastic behavior of the Highland Metal wire after 60 min ageing at 400 and 500 °C and the plastic deformation of the Copper NiTi wire after annealing due to the effect of copper in the alloy composition.


Subject(s)
Copper/chemistry , Hot Temperature , Materials Testing/methods , Mechanical Phenomena , Nickel/chemistry , Orthodontic Wires , Titanium/chemistry , Stress, Mechanical
13.
Eur J Nucl Med Mol Imaging ; 38(2): 252-62, 2011 Feb.
Article in English | MEDLINE | ID: mdl-20959974

ABSTRACT

PURPOSE: Cardiac PET/CT imaging is often performed in patients with pacemakers and implantable cardioverter defibrillator (ICD) leads. However, metallic implants usually produce artefacts on CT images which might propagate to CT-based attenuation-corrected (CTAC) PET images. The impact of metal artefact reduction (MAR) for CTAC of cardiac PET/CT images in the presence of pacemaker, ICD and ECG leads was investigated using both qualitative and quantitative analysis in phantom and clinical studies. METHODS: The study included 14 patients with various leads undergoing perfusion and viability examinations using dedicated cardiac PET/CT protocols. The PET data were corrected for attenuation using both artefactual CT images and CT images corrected using the MAR algorithm. The severity and magnitude of metallic artefacts arising from these leads were assessed on both linear attenuation coefficient maps (µ-maps) and attenuation-corrected PET images. CT and PET emission data were obtained using an anthropomorphic thorax phantom and a dedicated heart phantom made in-house incorporating pacemaker and ICD leads attached at the right ventricle of the heart. Volume of interest-based analysis and regression plots were performed for regions related to the lead locations. Bull's eye view analysis was also performed on PET images corrected for attenuation with and without the MAR algorithm. RESULTS: In clinical studies, the visual assessment of PET images by experienced physicians and quantitative analysis did not reveal erroneous interpretation of the tracer distribution or significant differences when PET images were corrected for attenuation with and without MAR. In phantom studies, the mean differences between tracer uptake obtained without and with MAR were 10.16±2.1% and 6.86±2.1% in the segments of the heart in the vicinity of metallic ICD or pacemaker leads, and were 4.43±0.5% and 2.98±0.5% in segments far from the leads. CONCLUSION: Although the MAR algorithm was able to effectively improve the quality of µ-maps, its clinical impact on the interpretation of PET images was not significant. Therefore cardiac PET images corrected for attenuation using CTAC in the presence of metallic leads can be interpreted without correction for metal artefacts. It should however be emphasized that in some special cases with multiple ICD leads attached to the myocardium wall, MAR might be useful for accurate attenuation correction.


Subject(s)
Artifacts , Defibrillators, Implantable/adverse effects , Heart/diagnostic imaging , Pacemaker, Artificial/adverse effects , Positron-Emission Tomography/methods , Tomography, X-Ray Computed/methods , Female , Humans , Image Interpretation, Computer-Assisted , Male , Metals/adverse effects , Phantoms, Imaging
14.
Phys Med Biol ; 55(3): 903-12, 2010 Feb 07.
Article in English | MEDLINE | ID: mdl-20071770

ABSTRACT

Over the past few years there has been much interest in the development of three-dimensional dosimeters to determine the complex absorbed dose distribution in modern radiotherapy techniques such as IMRT and IGRT. In routine methods used for three-dimensional dosimetry, polymer gels are commonly used. Recently, a novel transparent polymer dosimeter, known as PRESAGE, has been introduced in which a radiochromic color change is observed upon radiation. PRESAGE has some advantages over usual polymer gel dosimeters. It has been noted that the sensitivity of PRESAGE can be changed when different amounts of the components are used for its fabrication. This study has focused on the assessment of dosimetric characteristics of PRESAGE for various amounts of components in its formulation. To achieve this, PRESAGE dosimeters were fabricated using various amounts of their constituting components. Then the dosimeters were irradiated to (60)Co gamma photons for a range of radiation doses from 0 to 50 Gy. Consequently, the light absorption changes of the dosimeters were measured by a spectrophotometer at different post-irradiation time periods. It was generally observed that as the concentration of the radical initiator is increased, the PRESAGE dosimeter sensitivity is increased while its stability is decreased. Furthermore, it was noted that with the high concentration of the radical initiator and leuco dye, the sensitivity of PRESAGE is decreased.


Subject(s)
Radiometry/instrumentation , Radiometry/methods , Absorption , Cobalt Radioisotopes , Electrons , Gamma Rays , Light , Linear Models , Phantoms, Imaging , Photons , Polymers/radiation effects , Sensitivity and Specificity , Spectrophotometry , Time Factors , Water
15.
Radiat Environ Biophys ; 45(4): 301-6, 2006 Nov.
Article in English | MEDLINE | ID: mdl-17047979

ABSTRACT

Concentrations of 137Cs and 226Ra in the diet (foodstuffs and drinking water) of adult inhabitants in the high-level natural radiation area (HLNRA) of Ramsar, Iran have been determined. The annual intake of foodstuffs was estimated on the basis of their average annual consumption. Food samples collected from local markets were analyzed by means of a gamma spectrometer. The estimated annual dietary intakes of 137Cs and 226Ra were 130Bq and 245Bq, respectively. The concentrations of natural radionuclides in food and drinking water of the residents are higher than the world average, and are correlated with the high concentration of these radionuclides in soil and water. Calculations were also made to determine the potential dose to an individual consuming such diets.


Subject(s)
Cesium Radioisotopes/analysis , Food Contamination, Radioactive/analysis , Radiation Monitoring/statistics & numerical data , Radium/analysis , Water Supply/analysis , Humans , Iran
SELECTION OF CITATIONS
SEARCH DETAIL