Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Catheter Cardiovasc Interv ; 103(1): 209-218, 2024 01.
Article in English | MEDLINE | ID: mdl-37957842

ABSTRACT

BACKGROUND: Balloon post-dilation (BPD) is a widely adopted strategy to optimize acute results of TAVI, with a positive impact on both paravalvular leak and mean gradients. On the other hand, the inflation of the balloon inside prosthetic leaflets may damage them increasing the risk of structural valve deterioration (SVD). Furthermore, the impact of BPD on long-term clinical outcomes and valve hemodynamics is yet unknown. AIMS: To evaluate the impact of BPD on valve durability and long-term clinical outcomes in patients undergoing self-expanding transcatheter valve implantation (TAVI). METHODS: Echocardiographic and clinical data from the ClinicalService (a nation-based data repository and medical care project) were analyzed. Patients were divided into two groups, those who underwent BPD after TAVI and those who did not. Coprimary endpoints were all-cause death and SVD. Cumulative incidence functions for SVD were estimated. RESULTS: Among 1835 patients included in the study, 417 (22.7%) underwent BPD and 1418 (77.3%) did not undergo BPD. No statistically significant differences at 6-year follow-up were found between groups in terms of all-cause mortality (HR: 1.05, 95% CI: 0.9-1.22; p = 0.557) and SVD (2.1% vs. 1.4%, p = 0.381). In addition, BPD did not predispose to higher risk of cardiovascular death, myocardial infarction, valve thrombosis, and endocarditis at 6-year follow-up. CONCLUSIONS: BPD following TAVI with a self-expanding prosthesis does not seem to be associated with an increased risk of adverse clinical outcomes or SVD at 6-year follow-up.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/etiology , Dilatation , Treatment Outcome , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Prosthesis Design
2.
Sci Rep ; 13(1): 17448, 2023 10 14.
Article in English | MEDLINE | ID: mdl-37838795

ABSTRACT

Anomalous aortic origin of the coronary artery (AAOCA) is a rare disease associated with sudden cardiac death, usually related to physical effort in young people. Clinical routine tests fail to assess the ischemic risk, calling for novel diagnostic approaches. To this aim, some recent studies propose to assess the coronary blood flow (CBF) in AAOCA by computational simulations but they are limited by the use of data from literature retrieved from normal subjects. To overcome this limitation and obtain a reliable assessment of CBF, we developed a fully patient-specific lumped parameter model based on clinical imaging and in-vivo data retrieved during invasive coronary functional assessment of subjects with AAOCA. In such a way, we can estimate the CBF replicating the two hemodynamic conditions in-vivo analyzed. The model can mimic the effective coronary behavior with high accuracy and could be a valuable tool to quantify CBF in AAOCA. It represents the first step required to move toward a future clinical application with the aim of improving patient care. The study was registered at Clinicaltrial.gov with (ID: NCT05159791, date 2021-12-16).


Subject(s)
Aorta , Heart , Humans , Coronary Vessels/diagnostic imaging , Death, Sudden, Cardiac , Hemodynamics
3.
Circ Cardiovasc Interv ; 16(7): e012636, 2023 07.
Article in English | MEDLINE | ID: mdl-37417226

ABSTRACT

BACKGROUND: Anomalous aortic origin of coronary artery (AAOCA) with intramural segment is associated with risk of sudden cardiac death, probably related to a compressive mechanism exerted by the aorta. However, the intramural compression occurrence and magnitude during the cardiac cycle remain unknown. We hypothesized that (1) in end diastole, the intramural segment is narrower, more elliptic, and has greater resistance than extramural segment; (2) the intramural segment experiences a further compression in systole; and (3) morphometry and its systolic changes vary within different lumen cross-sections of the intramural segment. METHODS: Phasic changes of lumen cross-sectional coronary area, roundness (minimum/maximum lumen diameter), and hemodynamic resistance (Poiseuille law for noncircular sections) were derived from intravascular ultrasound pullbacks at rest for the ostial, distal intramural, and extramural segments. Data were obtained for 35 AAOCA (n=23 with intramural tract) after retrospective image-based gating and manual lumen segmentation. Differences between systolic and end-diastolic phases in each section, between sections of the same coronary, and between AAOCA with and without intramural tract were assessed by nonparametric statistical tests. RESULTS: In end diastole, both the ostial and distal intramural sections were more elliptical (P<0.001) than the reference extramural section and the correspondent sections in AAOCA without intramural segment. In systole, AAOCA with intramural segment showed a flattening at the ostium (-6.76% [10.82%]; P=0.024) and a flattening (-5.36% [16.56%]; P=0.011), a narrowing (-4.62% [11.38%]; P=0.020), and a resistance increase (15.61% [30.07%]; P=0.012) at the distal intramural section. No-intramural sections did not show morphological changes during the entire cardiac cycle. CONCLUSIONS: AAOCA with intramural segment has pathological segment-specific dynamic compression mainly in the systole under resting conditions. Studying AAOCA behavior with intravascular ultrasound during the cardiac cycle may help to evaluate and quantify the severity of the narrowing.


Subject(s)
Coronary Vessel Anomalies , Coronary Vessels , Humans , Coronary Vessels/diagnostic imaging , Coronary Vessels/pathology , Retrospective Studies , Cross-Sectional Studies , Coronary Vessel Anomalies/diagnostic imaging , Coronary Vessel Anomalies/complications , Treatment Outcome , Aorta/diagnostic imaging
4.
ESC Heart Fail ; 9(5): 3614-3618, 2022 10.
Article in English | MEDLINE | ID: mdl-35809025

ABSTRACT

Management of congenital coronary artery anomalies (CAA) is not standardized due to the variety of conditions included and their rare prevalence. Detection of CAA during myocardial infarction with non-obstructive coronary arteries (MINOCA) may induce clinicians to address the patient for surgery as CAA is not included in any algorithm1,2 for the management of MINOCA and American Association for Thoracic Surgery evidence-based guidelines suggest surgical repair for patients with anomalous aortic origin of a coronary artery and symptoms compatible with myocardial ischaemia.3 We present the case of a 35-year-old man with an anomalous origin of left coronary artery from right Valsalva sinus with pre-pulmonic course detected during urgent coronary angiography for suspected myocardial infarction. Stress cardiac magnetic resonance did not show signs of ischaemia at high-dose dobutamine but did reveal a recent myocarditis. This clinical case highlights the need for accurate risk stratification in CAA especially when confounding clinical scenarios co-exist.


Subject(s)
Coronary Artery Disease , Coronary Vessel Anomalies , Myocardial Infarction , Sinus of Valsalva , Male , Humans , Adult , Coronary Vessel Anomalies/complications , Coronary Vessel Anomalies/diagnosis , Coronary Vessel Anomalies/surgery , Myocardial Infarction/complications , Coronary Angiography , Sinus of Valsalva/abnormalities , Coronary Artery Disease/complications
5.
Cardiovasc Revasc Med ; 35: 19-26, 2022 02.
Article in English | MEDLINE | ID: mdl-33933374

ABSTRACT

PURPOSE: To compare in-hospital outcome of Evolut-R 34 mm vs. smaller Evolut-R devices and to identify predictors of paravalvular leak (PVL) and deep implantation specific for Evolut-R 34 mm. METHODS: This single-center retrospective study included 359 consecutive patients undergoing transcatheter aortic valve replacement (TAVR) with Evolut-R 34 mm (N = 84,23.4%) and Evolut-R 23/26/29 mm (N = 275,76.6%) between 2016 and 2019. RESULTS: Patients in Evolut-R 34 mm group were more frequently males, had lower STS score, ejection fraction, and mean aortic gradient compared to the Evolut-R 23/26/29 mm group. Horizontal aorta and large LVOT were more frequent findings in the Evolut-R 34 mm group, whereas calcium volume was comparable among the groups. During TAVR, mean implantation depth and contrast volume were greater in the Evolut-R 34 mm group, compared to the Evolut 23/26/29 mm group. Post-procedurally, 30-day mortality, ≥moderate PVL, device success and pacemaker implantation (PM) rates were comparable between groups. Among independent predictors of ≥moderate PVL, calcium volume (OR:1.04; p < 0.001) was predictive with different thresholds in both groups, whereas aortic angulation (OR:1.40; p = 0.005) was predictive only in Evolut-R 34 mm group at a cutoff of 60° (AUC:0.73; p = 0.043). Body weight (OR:1.03; p = 0.027), left ventricular outflow tract (LVOT) diameter (OR:1.34; p = 0.001), and mean aortic gradient (OR:0.96; p = 0.006) were independent predictors of deep implantation (mean depth ≥ 6 mm), with LVOT>27 mm being predictive specifically for Evolut-R 34 mm (AUC:0.66; p = 0.024). CONCLUSIONS: TAVR with Evolut-R 34 mm and Evolut-R 23/26/29 mm showed comparable in-hospital outcome. Aortic angulation >60° and LVOT >27 mm were predictive respectively of ≥moderate PVL and deep implantation specifically in Evolut-R 34 mm patients.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Hospitals , Humans , Male , Postoperative Complications/surgery , Prosthesis Design , Retrospective Studies , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
7.
EuroIntervention ; 8(6): 685-90, 2012 Oct.
Article in English | MEDLINE | ID: mdl-23086786

ABSTRACT

AIMS: Arterial access selection is crucial during transcatheter aortic valve implantation. When traditional femoral access has been deemed unfeasible the left subclavian artery has been used successfully. In cases where even the latter was ineligible, we opted, despite the lack of any data, for the right subclavian approach. We hereby present the results of the first series available. Our aim was to evaluate the feasibility and performance of the CoreValve ReValving System (CRS) implantation via the right subclavian artery in patients with contraindication to femoral and left subclavian accesses. METHODS AND RESULTS: Among 300 patients who have undergone CRS implantation, 70 (23%) have been treated via the subclavian approach, 10 via the right subclavian artery and 60 via the left. Demographic features were quite similar except for the presence of significant left subclavian disease in all patients treated via the right subclavian artery. The success rate was 100% for both groups. At 30-day follow-up, there was no significant difference in terms of all-cause mortality and cardiac mortality between right vs. left subclavian approach (0% vs. 6.6% and 0% vs. 6.6%, respectively). Consistent results were observed at a mean follow-up of 12±7.9 months (all-cause mortality: 10% vs. 15%). Incidences of new AV block requiring PM implantation were also statistically equivalent. CONCLUSIONS: CRS implantation via the right subclavian artery was as feasible and safe as the left subclavian approach. It poses very particular technical issues but should be considered when more conventional approaches are inadequate in order to provide patients with a further chance to be treated effectively.


Subject(s)
Aortic Valve , Bioprosthesis , Cardiac Catheterization/instrumentation , Heart Valve Diseases/therapy , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis , Subclavian Artery , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Cardiac Catheterization/adverse effects , Cardiac Catheterization/mortality , Chi-Square Distribution , Feasibility Studies , Female , Femoral Artery , Heart Valve Diseases/diagnostic imaging , Heart Valve Diseases/mortality , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/mortality , Humans , Italy , Male , Prosthesis Design , Radiography, Interventional , Retrospective Studies , Subclavian Artery/diagnostic imaging , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL