Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 108
Filter
1.
Article in English | MEDLINE | ID: mdl-38773853

ABSTRACT

Transfemoral transcatheter aortic valve replacement is the preferred primary access route whenever possible. Despite advancements in expertise and delivery system profiles, complications associated with the primary femoral access still significantly affect procedural morbidity and outcomes. The current standard for accurate main access planning involves proper preprocedural evaluation guided by computed tomography. Several baseline clinical and anatomical features serve as predictors for the risk of vascular injury occurring during or after transcatheter aortic valve replacement. In this paper, we aimed at reviewing the most up-to-date knowledge of the topic for a safe transfemoral access approach according to a paradigm we have called "PIGTAIL."

2.
J Clin Med ; 13(5)2024 Mar 06.
Article in English | MEDLINE | ID: mdl-38592382

ABSTRACT

Background: Currently, transcatheter aortic valve implantation (TAVI) is the standard procedure recommended for patients over 75 years of age with symptomatic aortic valve stenosis. Percutaneous transfemoral (TF) access is the main route used to perform the procedure. Among periprocedural complications, access-related ones are the most frequent, potentially leading to prolonged in-hospital stays and transfusions. Methods: We performed a retrospective analysis of prospectively collected data on consecutive patients undergoing TF-TAVI with the latest generation balloon-expandable transcatheter valve between 2013 and 2022. Results: A total of 600 patients were analyzed, differentiating the population between ultrasound-guided and blind common femoral artery puncture. Valve Academic Research Consortium 3 (VARC-3)criteria were used to report at 30 days and follow-up. In our propensity-matched comparison of the two groups, we found a strong reduction in access-related complications in the echo-guided group, particularly in terms of reduction of major and minor bleedings. We also found a significant trend in reduction of local complications, such as pseudoaneurysms, hematomas, arterio-venous fistulas, dissection of the femoral or iliac arteries, and stenosis. Conclusions: Although there is a lack of consensus on the role of ultrasound-guided puncture, we found better outcomes for patients having an echo-guided puncture of the main access, particularly with regard to access-related complications, early mobilization, and early discharge home.

3.
JACC Cardiovasc Interv ; 16(21): 2615-2627, 2023 11 13.
Article in English | MEDLINE | ID: mdl-37968032

ABSTRACT

BACKGROUND: Mitral valve-in-valve (ViV) is associated with suboptimal hemodynamics and rare left ventricular outflow tract (LVOT) obstruction. OBJECTIVES: This study aimed to determine whether device position and asymmetry are associated with these outcomes. METHODS: Patients undergoing SAPIEN 3 (Edwards Lifesciences) mitral ViV included in the VIVID (Valve-in-Valve International Data) Registry were studied. Clinical endpoints are reported according to Mitral Valve Academic Research Consortium definitions. Residual mitral valve stenosis was defined as mean gradient ≥5 mm Hg. Depth of implantation (percentage of transcatheter heart valve [THV] atrial to the bioprosthesis ring) and asymmetry (ratio of 2 measures of THV height) were evaluated. RESULTS: A total of 222 patients meeting the criteria for optimal core lab evaluation were studied (age 74 ± 11.6 years; 61.9% female; STS score = 8.3 ± 7.1). Mean asymmetry was 6.2% ± 4.4%. Mean depth of implantation was 19.0% ± 10.3% atrial. Residual stenosis was common (50%; mean gradient 5.0 ± 2.6 mm Hg). LVOT obstruction occurred in 7 cases (3.2%). Implantation depth was not a predictor of residual stenosis (OR: 1.19 [95% CI: 0.92-1.55]; P = 0.184), but more atrial implantation was protective against LVOT obstruction (0.7% vs 7.1%; P = 0.009; per 10% atrial, OR: 0.48 [95% CI: 0.24-0.98]; P = 0.044). Asymmetry was found to be an independent predictor of residual stenosis (per 10% increase, OR: 2.30 [95% CI: 1.10-4.82]; P = 0.027). CONCLUSIONS: Valve stenosis is common after mitral ViV. Asymmetry was associated with residual stenosis. Depth of implantation on its own was not associated with residual stenosis but was associated with LVOT obstruction. Technical considerations to reduce postdeployment THV asymmetry should be considered.


Subject(s)
Atrial Fibrillation , Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Humans , Female , Middle Aged , Aged , Aged, 80 and over , Male , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Heart Valve Prosthesis Implantation/adverse effects , Constriction, Pathologic/etiology , Treatment Outcome , Cardiac Catheterization/adverse effects , Hemodynamics , Registries , Prosthesis Design
4.
Am J Cardiol ; 209: 173-180, 2023 12 15.
Article in English | MEDLINE | ID: mdl-37858597

ABSTRACT

Low-flow low-gradient (LF-LG) aortic stenosis (AS) may occur with preserved or depressed left ventricular ejection fraction (LVEF). Both situations represent the most challenging subset of patients to manage and generally have a poor prognosis. Few and controversial data exist on the outcomes of these patients compared with normal flow-high gradient (NF-HG) AS after transcatheter aortic valve replacement (TAVR). We sought to characterize different transvalvular flow-gradient patterns and to examine their prognostic value after TAVR. We enrolled 1,208 patients with severe AS and categorized as follow: 976 patients NF-HG (mean aortic pressure gradient [MPG] ≥40 mm Hg), 107 paradoxical LF-LG (pLF-LG, MPG <40 mm Hg, LVEF ≥50%, stroke volume index <35 ml/m2), and 125 classical LF-LG (cLF-LG) (MPG <40 mm Hg, LVEF <50%, stroke volume index <35 ml/m2). When compared with NF-HG and pLF-LG, cLF-LG had a worse symptomatic status (New York Heart Association III to IV 86% vs 62% and 67%, p <0.001), a higher prevalence of eccentric hypertrophy and a higher level of LV global afterload reflected by a higher valvuloarterial impedance. Valvular function after TAVR was excellent over time in all patients. While 30-day mortality (p = 0.911) did not differ significantly among groups, cLF-LG had a lower 5-year survival rate (LF-LG 50% vs pLF-LG 62% and NF-HG 68%, p <0.05). cLF-LG was associated with a hazard ratio for mortality of 2.41 (95% confidence interval 1.65 to 3.52, p <0.001). In conclusion, TAVR is an effective procedure regardless of transvalvular flow-gradient patterns. However, special care should be given to characterized hemodynamic of AS, as patients with pLF-LG had similar survival rates than patients with NF-HG, whereas cLF-LG is associated with a twofold increased risk of mortality at 5-year follow-up.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Stroke Volume , Ventricular Function, Left , Treatment Outcome , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Severity of Illness Index
5.
G Ital Cardiol (Rome) ; 24(2): 122-124, 2023 Feb.
Article in Italian | MEDLINE | ID: mdl-36735310

ABSTRACT

We report the case of a 28-year-old Caucasian patient symptomatic for low-threshold angina. Coronary angiography ruled out significant coronary stenosis. He was diagnosed with familial hypercholesterolemia and severe aortic stenosis in a setting of bicuspid valve disease. Preoperative evaluation showed diffuse atheromatous disease and severe calcification of the ascending aorta. The patient was treated by endarterectomy of the ascending aorta, non-coronary sinus enlargement patch and aortic valve replacement. This case report emphasizes the role of aortic valve disease in patients with familial hypercholesterolemia and highlights the complexity of surgical management of this condition.


Subject(s)
Aortic Valve Stenosis , Bicuspid Aortic Valve Disease , Calcinosis , Hypercholesterolemia , Hyperlipoproteinemia Type II , Male , Humans , Adult , Bicuspid Aortic Valve Disease/complications , Hypercholesterolemia/complications , Aorta, Thoracic , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Calcinosis/complications , Calcinosis/diagnostic imaging , Hyperlipoproteinemia Type II/complications
6.
Rev. bras. cir. cardiovasc ; 37(5): 765-768, Sept.-Oct. 2022. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1407298

ABSTRACT

ABSTRACT Transfemoral transcatheter aortic valve replacement (TAVR) is currently the standard catheter-based treatment of severe aortic stenosis patients. Being the transfemoral route not feasible, other access sites could be chosen. Transaortic TAVR via either a J mini-sternotomy or a right anterolateral mini-thoracotomy is a good option for patients having tricky thoracoabdominal aorta. Some tips and tricks may help in getting a fast and safe transaortic procedure.

7.
Braz J Cardiovasc Surg ; 37(4): 595-598, 2022 08 16.
Article in English | MEDLINE | ID: mdl-35976212

ABSTRACT

Iatrogenic acute aortic dissections during percutaneous coronary interventions are an extremely rare but potentially life-threatening complication, occurring in less than 0.02% of transcatheter procedures. We report three patients with different characteristics suffering from iatrogenic aortic dissection during percutaneous coronary intervention successfully treated with an emergency open-heart surgery. A conservative strategy should be pursuit only in small, localized lesions.


Subject(s)
Aortic Dissection , Percutaneous Coronary Intervention , Aortic Dissection/diagnostic imaging , Aortic Dissection/etiology , Aortic Dissection/surgery , Coronary Vessels/surgery , Humans , Iatrogenic Disease , Percutaneous Coronary Intervention/adverse effects
8.
Rev. bras. cir. cardiovasc ; 37(4): 595-598, Jul.-Aug. 2022. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1394733

ABSTRACT

ABSTRACT Iatrogenic acute aortic dissections during percutaneous coronary interventions are an extremely rare but potentially life-threatening complication, occurring in less than 0.02% of transcatheter procedures. We report three patients with different characteristics suffering from iatrogenic aortic dissection during percutaneous coronary intervention successfully treated with an emergency open-heart surgery. A conservative strategy should be pursuit only in small, localized lesions.

9.
Braz J Cardiovasc Surg ; 37(5): 765-768, 2022 10 08.
Article in English | MEDLINE | ID: mdl-35895988

ABSTRACT

Transfemoral transcatheter aortic valve replacement (TAVR) is currently the standard catheter-based treatment of severe aortic stenosis patients. Being the transfemoral route not feasible, other access sites could be chosen. Transaortic TAVR via either a J mini-sternotomy or a right anterolateral mini-thoracotomy is a good option for patients having tricky thoracoabdominal aorta. Some tips and tricks may help in getting a fast and safe transaortic procedure.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve Stenosis/surgery , Treatment Outcome , Sternotomy , Thoracotomy , Aortic Valve/surgery , Risk Factors , Heart Valve Prosthesis Implantation/methods
10.
Circ Res ; 131(3): 239-257, 2022 07 22.
Article in English | MEDLINE | ID: mdl-35770662

ABSTRACT

BACKGROUND: Conversion of cardiac stromal cells into myofibroblasts is typically associated with hypoxia conditions, metabolic insults, and/or inflammation, all of which are predisposing factors to cardiac fibrosis and heart failure. We hypothesized that this conversion could be also mediated by response of these cells to mechanical cues through activation of the Hippo transcriptional pathway. The objective of the present study was to assess the role of cellular/nuclear straining forces acting in myofibroblast differentiation of cardiac stromal cells under the control of YAP (yes-associated protein) transcription factor and to validate this finding using a pharmacological agent that interferes with the interactions of the YAP/TAZ (transcriptional coactivator with PDZ-binding motif) complex with their cognate transcription factors TEADs (TEA domain transcription factors), under high-strain and profibrotic stimulation. METHODS: We employed high content imaging, 2-dimensional/3-dimensional culture, atomic force microscopy mapping, and molecular methods to prove the role of cell/nuclear straining in YAP-dependent fibrotic programming in a mouse model of ischemia-dependent cardiac fibrosis and in human-derived primitive cardiac stromal cells. We also tested treatment of cells with Verteporfin, a drug known to prevent the association of the YAP/TAZ complex with their cognate transcription factors TEADs. RESULTS: Our experiments suggested that pharmacologically targeting the YAP-dependent pathway overrides the profibrotic activation of cardiac stromal cells by mechanical cues in vitro, and that this occurs even in the presence of profibrotic signaling mediated by TGF-ß1 (transforming growth factor beta-1). In vivo administration of Verteporfin in mice with permanent cardiac ischemia reduced significantly fibrosis and morphometric remodeling but did not improve cardiac performance. CONCLUSIONS: Our study indicates that preventing molecular translation of mechanical cues in cardiac stromal cells reduces the impact of cardiac maladaptive remodeling with a positive effect on fibrosis.


Subject(s)
Adaptor Proteins, Signal Transducing , Phosphoproteins , Adaptor Proteins, Signal Transducing/metabolism , Animals , Fibrosis , Humans , Mice , Phosphoproteins/metabolism , Trans-Activators/genetics , Trans-Activators/metabolism , Transcription Factors/genetics , Transcription Factors/metabolism , Transcriptional Activation , Verteporfin , YAP-Signaling Proteins
11.
Front Cardiovasc Med ; 9: 850393, 2022.
Article in English | MEDLINE | ID: mdl-35402526

ABSTRACT

The increasing incidence of calcific aortic valve disease necessitates the elaboration of new strategies to retard the progression of the pathology with an innovative solution. While the increasing diffusion of the transcatheter aortic valve replacements (TAVRs) allows a mini-invasive approach to aortic valve substitution as an alternative to conventional surgical replacement (SAVR) in an always larger patient population, TAVR implantation still has contraindications for young patients. In addition, it is liable to undergo calcification with the consequent necessity of re-intervention with conventional valve surgery or repeated implantation in the so-called TAVR-in-TAVR procedure. Inspired by applications for non-cardiac pathologies or for vascular decalcification before stenting (i.e., coronary lithotripsy), in the present study, we show the feasibility of human valve treatment with a mini-invasive device tailored to deliver shockwaves to the calcific leaflets. We provide evidence of efficient calcium deposit ruptures in human calcified leaflets treated ex vivo and the safety of the treatment in pigs. The use of this device could be helpful to perform shockwaves valvuloplasty as an option to retard TAVR/SAVR, or as a pretreatment to facilitate prosthesis implantation and minimize the occurrence of paravalvular leak.

12.
J Card Surg ; 37(7): 1887-1893, 2022 Jul.
Article in English | MEDLINE | ID: mdl-35249231

ABSTRACT

AIMS: In the clinical practice a noteworthy proportion of severe symptomatic aortic stenosis patients presents with low-flow low-gradients features, these having reported a less favorable prognosis even when surgically or transcatheter treated. METHODS AND RESULTS: We retrospectively analyzed the prospectively collected data on 1051 consecutive patients undergone balloon-expandable transcatheter aortic valve replacement at our Institution from January 2008 to January 2020. We divided the population according with a mean aortic gradient (MAG) < or ≥40 mmHg and we performed a propensity-matched analysis based on the Society of Thoracic Surgery Score and age, obtaining two homogeneous groups of 314 patients each (Groups A and B, respectively). We then analyzed the outcomes of the two groups by implementing adjusted Cox models adjusted for significant clinical differences between the two groups, such as sex, ejection fraction, comorbidities and other variables not included in the propensity-matched analysis. The only variable associated with both cardiovascular and all-cause events was an ejection fraction ≤35%. Finally, a sensitivity analysis found that an ejection fraction ≤35% was associated with an increase cardiovascular and all-cause mortality only in patients with an indexed end-diastolic volume >97 ml/m2 (p = .0438 and .3363, respectively). CONCLUSIONS: In our series a MAG <40 mmHg was not found to be per se an independent risk factor for cardiac and all-cause mortality after transcatheter aortic valve replacement. The ejection fraction was found to be an independent risk factor only in the context of enlarged left ventricular dimensions.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Aortic Valve/surgery , Humans , Prognosis , Retrospective Studies , Risk Factors , Stroke Volume , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome , Ventricular Function, Left
13.
Eur J Prev Cardiol ; 29(7): 997-1004, 2022 05 25.
Article in English | MEDLINE | ID: mdl-33624003

ABSTRACT

AIMS: Patients with coronary heart disease (CHD) are at very high risk of recurrent events. A strategy to reduce excess risk might be to deliver structured secondary prevention programmes, but their efficacy has been mostly evaluated in the short term and in experimental settings. This is a retrospective case-control study aimed at assessing, in the real world, the efficacy of a secondary prevention programme in reducing long-term coronary event recurrences after coronary artery bypass surgery (CABG). METHODS AND RESULTS: Programme participants (henceforth 'cases') were men and women aged <75 years subjected to CABG between 2002 and 2014, living within 100 km of the hospital. Key programme actions included optimization of treatments according to the most updated European preventive guidelines, surveillance of therapy adherence, and customized lifestyle counselling. Controls were analogous patients not involved in the programme because living farther than 100 km away, matched 1:1 with cases for gender, age at CABG, and year of CABG. Both groups (n = 1248) underwent usual periodic cardiology follow-up at our centre. Data on symptomatic or silent CHD recurrences were obtained from the hospital electronic health records. Cox analysis (adjusted for baseline differences between groups) shows that programme participation was associated with a significantly lower incidence throughout 5 years post-CABG of symptomatic [hazard ratio (95% confidence interval): 0.59 (0.38-0.94)] and silent [0.53 (0.31-0.89)] coronary recurrences. CONCLUSION: In a real-world setting, taking part in a structured longstanding secondary prevention programme, in addition to usual cardiology care, meaningfully lowers the risk of coronary recurrences.


Subject(s)
Cardiovascular Diseases , Coronary Artery Disease , Cardiovascular Diseases/etiology , Case-Control Studies , Coronary Artery Bypass/adverse effects , Coronary Artery Disease/etiology , Coronary Artery Disease/surgery , Female , Humans , Male , Recurrence , Retrospective Studies , Secondary Prevention , Treatment Outcome
14.
J Am Coll Cardiol ; 77(18): 2263-2273, 2021 05 11.
Article in English | MEDLINE | ID: mdl-33958122

ABSTRACT

BACKGROUND: Permanent pacemaker implantation (PPI) remains one of the main drawbacks of transcatheter aortic valve replacement (TAVR), but scarce data exist on PPI after valve-in-valve (ViV) TAVR, particularly with the use of newer-generation transcatheter heart valves (THVs). OBJECTIVES: The goal of this study was to determine the incidence, factors associated with, and clinical impact of PPI in a large series of ViV-TAVR procedures. METHODS: Data were obtained from the multicenter VIVID Registry and included the main baseline and procedural characteristics, in-hospital and late (median follow-up: 13 months [interquartile range: 3 to 41 months]) outcomes analyzed according to the need of periprocedural PPI. All THVs except CoreValve, Cribier-Edwards, Sapien, and Sapien XT were considered to be new-generation THVs. RESULTS: A total of 1,987 patients without prior PPI undergoing ViV-TAVR from 2007 to 2020 were included. Of these, 128 patients (6.4%) had PPI after TAVR, with a significant decrease in the incidence of PPI with the use of new-generation THVs (4.7% vs. 7.4%; p = 0.017), mainly related to a reduced PPI rate with the Evolut R/Pro versus CoreValve (3.7% vs. 9.0%; p = 0.002). There were no significant differences in PPI rates between newer-generation balloon- and self-expanding THVs (6.1% vs. 3.9%; p = 0.18). In the multivariable analysis, older age (odds ratio [OR]: 1.05 for each increase of 1 year; 95% confidence interval [CI]: 1.02 to 1.07; p = 0.001), larger THV size (OR: 1.10; 95% CI: 1.01 to 1.20; p = 0.02), and previous right bundle branch block (OR: 2.04; 95% CI: 1.00 to 4.17; p = 0.05) were associated with an increased risk of PPI. There were no differences in 30-day mortality between the PPI (4.7%) and no-PPI (2.7%) groups (p = 0.19), but PPI patients exhibited a trend toward higher mortality risk at follow-up (hazard ratio: 1.39; 95% CI: 1.02 to 1.91; p = 0.04; p = 0.08 after adjusting for age differences between groups). CONCLUSIONS: In a contemporary large series of ViV-TAVR patients, the rate of periprocedural PPI was relatively low, and its incidence decreased with the use of new-generation THV systems. PPI following ViV-TAVR was associated with a trend toward increased mortality at follow-up.


Subject(s)
Pacemaker, Artificial , Transcatheter Aortic Valve Replacement/methods , Aged , Aged, 80 and over , Female , Humans , Male , Prosthesis Implantation , Registries
15.
J Clin Med ; 10(5)2021 Feb 25.
Article in English | MEDLINE | ID: mdl-33669044

ABSTRACT

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is an established technique to treat severe symptomatic aortic stenosis patients with a wide range of surgical risk. Currently, the common femoral artery is the first choice as the main access route for the procedure. The objective of this observational study is to report our experience on percutaneous and surgical cut-down transfemoral TAVRs comparing the two approaches. METHODS: From January 2014 to January 2019, five hundred eleven consecutive patients underwent TAVR for severe symptomatic aortic stenosis. We analyzed only elective transfemoral procedures. After propensity score-matching based on age, sex, EuroSCORE II, mean aortic gradient, and left ventricular ejection fraction, we obtained two homogeneous populations: surgical cut-down (n = 119) and percutaneous (n = 225), which were labeled Group 1 and Group 2, respectively. RESULTS: The main findings were that there were no significant procedural outcome differences between the two groups, but Group 2 patients had a shorter length of hospital stay and were more frequently discharged home. At follow-up, Group 1 patients had lower survival rates. CONCLUSIONS: An accurate preoperative assessment of the femoral access is mandatory to achieve satisfactory outcomes with transfemoral TAVRs. Nevertheless, the percutaneous approach allows shorter in-hospital stay and the need for rehabilitation, thus potentially decreasing the costs of the procedure.

16.
J Card Surg ; 36(6): 2095-2098, 2021 Jun.
Article in English | MEDLINE | ID: mdl-33709408

ABSTRACT

Fully percutaneous transfemoral transcatheter aortic valve replacement (TF-TAVR) is currently the standard of the catheter-based treatment of severe aortic stenosis patients. Even though experience, lower delivery catheters profile and improved vascular closure devices performances have resulted in an overall reduction of both vascular and bleeding complications after TAVR, femoral pseudoaneurysm due to incomplete local hemostasis may occur, prolonging the in-hospital length of stay, causing discomfort to the patient and potentially evolving in serious consequences affecting the outcome. We report two successful percutaneous ultrasound-guided closure of both the main and secondary femoral access pseudoaneurysm.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Femoral Artery/diagnostic imaging , Femoral Artery/surgery , Humans , Retrospective Studies , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
17.
Cardiovasc Res ; 117(6): 1557-1566, 2021 05 25.
Article in English | MEDLINE | ID: mdl-33705542

ABSTRACT

AIMS: Patients with severe respiratory syndrome caused by SARS-CoV-2 undergo cardiac complications due to hyper-inflammatory conditions. Although the presence of the virus has been detected in the myocardium of infected patients, and infection of induced pluripotent cell-derived cardiomyocytes has been demonstrated, the reported expression of Angiotensin-Converting Enzyme-2 (ACE2) in cardiac stromal cells suggests that SARS-CoV-2 may determine cardiac injury by sustaining productive infection and increasing inflammation. METHODS AND RESULTS: We analysed expression of ACE2 receptor in primary human cardiac stromal cells derived from cardiospheres, using proteomics and transcriptomics before exposing them to SARS-CoV-2 in vitro. Using conventional and high sensitivity PCR methods, we measured virus release in the cellular supernatants and monitored the intracellular viral bioprocessing. We performed high-resolution imaging to show the sites of intracellular viral production and demonstrated the presence of viral particles in the cells with electron microscopy. We finally used RT-qPCR assays to detect genes linked to innate immunity and fibrotic pathways coherently regulated in cells after exposure to the virus. CONCLUSIONS: Our findings indicate that cardiac stromal cells are susceptible to SARS-CoV-2 infection and produce variable viral yields depending on the extent of cellular ACE2 receptor expression. Interestingly, these cells also evolved towards hyper-inflammatory/pro-fibrotic phenotypes independently of ACE2 levels. Thus, SARS-CoV-2 infection of myocardial stromal cells could be involved in cardiac injury and explain the high number of complications observed in severe cases of COVID-19.


Subject(s)
Angiotensin-Converting Enzyme 2/metabolism , COVID-19/virology , Heart Diseases/virology , Myocardium/enzymology , Receptors, Virus/metabolism , SARS-CoV-2/pathogenicity , Stromal Cells/virology , Virion/pathogenicity , Aged , Aged, 80 and over , Angiotensin-Converting Enzyme 2/genetics , Animals , COVID-19/complications , Chlorocebus aethiops , Female , Fibrosis , Heart Diseases/enzymology , Heart Diseases/pathology , Host-Pathogen Interactions , Humans , Inflammation Mediators/metabolism , Male , Middle Aged , Myocardium/ultrastructure , Phenotype , Receptors, Virus/genetics , SARS-CoV-2/ultrastructure , Spheroids, Cellular , Stromal Cells/enzymology , Stromal Cells/ultrastructure , Vero Cells , Virion/ultrastructure
19.
Curr Cardiol Rev ; 17(4): e290421188337, 2021.
Article in English | MEDLINE | ID: mdl-33238845

ABSTRACT

Despite the technological advancements in the last 40 years, conditions such as refractory cardiogenic shock and cardiac arrest still present a very high mortality rate in real-world clinical practice. In this light, we have reviewed the techniques, indications, contraindications, and results of the socalled Veno-Arterial Extracorporeal Circulatory Membrane Oxygenation (VA-ECMO) in the adult population to evaluate the current results of this temporary cardio-pulmonary support as salvage and/or bridge therapy in the patient suffering from refractory cardiogenic shock or cardio-circulatory arrest. The results are encouraging, especially in the setting of refractory cardiogenic shock and in-hospital cardiac arrest. Among a selected population, the prompt institution of a VA-ECMO may radically change the prognosis by sustaining vital functions while looking for the leading cause or waiting for the reversal of the temporary cardio-respiratory negative condition. The future directions aim to standardized and shared protocols, miniaturization of the machines, and possibly the institution of specialized "ECMO teams" for in and the out-of-hospital institution of the tool.


Subject(s)
Extracorporeal Membrane Oxygenation , Adult , Cardiovascular System , Heart Arrest/therapy , Humans , Prognosis , Shock, Cardiogenic/therapy
20.
J Card Surg ; 35(8): 2089-2092, 2020 Aug.
Article in English | MEDLINE | ID: mdl-32652613

ABSTRACT

Multiple valve replacements are known to carry additional risk of morbidity and mortality in redo context. Currently, a transcatheter-based valve-in-valve approach could be useful in reducing potential serious consequences. On the other hand, this approach poses several technical challenges regarding the device and the procedural aspects. We present the case of a 78-year-old man who presented with symptoms of heart failure due to mitral and aortic bioprosthesis degenerations who was deemed to be at extremely high risk for a conventional redo surgery. A two-step transcatheter-based approach was planned and a transfemoral aortic valve-in-valve procedure was followed by a transapical mitral valve-in-valve implantation with a favorable early and long-term outcome.


Subject(s)
Aortic Valve/surgery , Bioprosthesis , Cardiac Catheterization/methods , Heart Valve Prosthesis Implantation/methods , Mitral Valve/surgery , Transcatheter Aortic Valve Replacement/methods , Aged , Aortic Valve Stenosis/surgery , Humans , Male , Mitral Valve Stenosis/surgery , Patient Care Team , Reoperation , Stroke Volume , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...