Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 17 de 17
Filter
1.
Echocardiography ; 33(3): 459-71, 2016 Mar.
Article in English | MEDLINE | ID: mdl-26757247

ABSTRACT

We describe our process for quality improvement (QI) for a 3-year accreditation cycle in echocardiography by the Intersocietal Accreditation Commission (IAC) for a large group practice. Echocardiographic laboratory accreditation by the IAC was introduced in 1996, which is not required but could impact reimbursement. To ensure high-quality patient care and community recognition as a facility committed to providing high-quality echocardiographic services, we applied for IAC accreditation in 2010. Currently, there is little published data regarding the IAC process to meet echocardiography standards. We describe our approach for developing a multicampus QI process for echocardiographic laboratory accreditation during the 3-year cycle of accreditation by the IAC. We developed a quarterly review assessing (1) the variability of the interpretations, (2) the quality of the examinations, (3) a correlation of echocardiographic studies with other imaging modalities, (4) the timely completion of reports, (5) procedure volume, (6) maintenance of Continuing Medical Education credits by faculty, and (7) meeting Appropriate Use Criteria. We developed and implemented a multicampus process for QI during the 3-year accreditation cycle by the IAC for Echocardiography. We documented both the process and the achievement of those metrics by the Echocardiography Laboratories at the Ochsner Medical Institutions. We found the QI process using IAC standards to be a continuous educational experience for our Echocardiography Laboratory physicians and staff. We offer our process as an example and guide for other echocardiography laboratories who wish to apply for such accreditation or reaccreditation.


Subject(s)
Accreditation/standards , Echocardiography/standards , Laboratories, Hospital/standards , Process Assessment, Health Care/standards , Quality Assurance, Health Care/standards , Quality Improvement/standards , Louisiana
2.
Circ Cardiovasc Imaging ; 7(3): 430-437, 2014 May.
Article in English | MEDLINE | ID: mdl-24676783

ABSTRACT

BACKGROUND: Cardiovascular disease is an important cause of morbidity and mortality in sickle cell disease (SCD). We sought to characterize sickle cell cardiomyopathy using multimodality noninvasive cardiovascular testing and identify potential causative mechanisms. METHODS AND RESULTS: Stable adults with SCD (n=38) and healthy controls (n=13) prospectively underwent same day multiparametric cardiovascular magnetic resonance (cine, T2* iron, vasodilator first pass myocardial perfusion, and late gadolinium enhancement imaging), transthoracic echocardiography, and applanation tonometry. Compared with controls, patients with SCD had severe dilation of the left ventricle (124±27 vs 79±12 mL/m(2)), right ventricle (127±28 vs 83±14 mL/m(2)), left atrium (65±16 vs 41±9 mL/m(2)), and right atrium (78±17 vs 56±17 mL/m(2); P<0.01 for all). Patients with SCD also had a 21% lower myocardial perfusion reserve index than control subjects (1.47±0.34 vs 1.87±0.37; P=0.034). A significant subset of patients with SCD (25%) had evidence of late gadolinium enhancement, whereas only 1 patient had evidence of myocardial iron overload. Diastolic dysfunction was present in 26% of patients with SCD compared with 8% in controls. Estimated filling pressures (E/e', 9.3±2.7 vs 7.3±2.0; P=0.0288) were higher in patients with SCD. Left ventricular dilation and the presence of late gadolinium enhancement were inversely correlated to hepatic T2* times (ie, hepatic iron overload because of frequent blood transfusions; P<0.05 for both), whereas diastolic dysfunction and increased filling pressures were correlated to aortic stiffness (augmentation pressure and index, P<0.05 for all). CONCLUSIONS: Sickle cell cardiomyopathy is characterized by 4-chamber dilation and in some patients myocardial fibrosis, abnormal perfusion reserve, diastolic dysfunction, and only rarely myocardial iron overload. Left ventricular dilation and myocardial fibrosis are associated with increased blood transfusion requirements, whereas left ventricular diastolic dysfunction is predominantly correlated with increased aortic stiffness. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT01044901.


Subject(s)
Anemia, Sickle Cell/pathology , Cardiomyopathies/pathology , Adult , Anemia, Sickle Cell/complications , Cardiomyopathies/complications , Cohort Studies , Contrast Media , Echocardiography/methods , Female , Gadolinium DTPA , Humans , Image Enhancement/methods , Image Processing, Computer-Assisted/methods , Male
3.
Int J Cardiovasc Imaging ; 29(2): 285-93, 2013 Feb.
Article in English | MEDLINE | ID: mdl-22752362

ABSTRACT

Currently, no real-time three-dimensional echocardiographic (RT3DE) indices are recommended by the official guidelines for the assessment of diastolic dysfunction (DD). We hypothesized that recent developments in RT3DE imaging technology that allow dynamic quantification of both left ventricular (LV) volume and 3D myocardial deformation, could be utilized to objectively assess DD. Transthoracic RT3DE datasets were acquired (Philips iE33, X5 transducer, frame rate 19 ± 4) in 76 subjects, including 20 normal controls (NL), 16 mild DD, 20 moderate DD and 20 severe DD (grade 1, 2 and 3, respectively, using ASE guideline). Images were analyzed using prototype software (TomTec) that performs 3D speckle tracking to generate time curves of LV volume and segmental myocardial strain. Indices of diastolic LV function were calculated: volume at 25, 50 and 75 % of filling duration (FD) in percent of end-diastolic volume (volume index, LVVi), and rapid filling volume (RFV) fraction. Temporal indices included: FD in % of RR, and rapid filling duration (RFD) in % of FD. Additionally, longitudinal, radial and circumferential strains at 25, 50 and 75 % of FD were calculated. Inter-groups differences were tested using ANOVA. LVVi and RFV fraction showed a biphasic pattern with the severity of DD characterized by an initial decrease (grade 1), a pseudo-normalization (grade 2), and then an increase above normal (grade 3). FD progressively decreased with severity of DD. RFD was significantly increased in all 3 groups compared to NL. After normalization by peak systolic values, all three strain components showed a linear pattern with the severity of DD, suggesting potential clinical usefulness. This is the first study to show that current RT3DE technology allows combined quantitative analysis of LV volume and 3D myocardial strain, which is sensitive enough to demonstrate differences in myocardial relaxation in patients with different degrees of DD.


Subject(s)
Diastole , Echocardiography, Doppler , Echocardiography, Three-Dimensional , Ventricular Dysfunction, Left/diagnostic imaging , Ventricular Function, Left , Adult , Aged , Analysis of Variance , Biomechanical Phenomena , Case-Control Studies , Feasibility Studies , Female , Humans , Image Interpretation, Computer-Assisted , Male , Middle Aged , Predictive Value of Tests , Severity of Illness Index , Stroke Volume , Time Factors , Ventricular Dysfunction, Left/physiopathology
4.
Am J Respir Crit Care Med ; 186(4): 359-68, 2012 Aug 15.
Article in English | MEDLINE | ID: mdl-22679008

ABSTRACT

RATIONALE: An increased tricuspid regurgitation jet velocity (TRV > 2.5 m/s) and pulmonary hypertension defined by right heart catheterization both independently confer increased mortality in sickle cell disease (SCD). OBJECTIVES: We explored the usefulness of peripheral blood mononuclear cell-derived gene signatures as biomarkers for an elevated TRV in SCD. METHODS: Twenty-seven patients with SCD underwent echocardiography and peripheral blood mononuclear cell isolation for expression profiling and 112 patients with SCD were genotyped for single-nucleotide polymorphisms. MEASUREMENTS AND MAIN RESULTS: Genome-wide gene and miRNA expression profiles were correlated against TRV, yielding 631 transcripts and 12 miRNAs. Support vector machine analysis identified a 10-gene signature including GALNT13 (encoding polypeptide N-acetylgalactosaminyltransferase 13) that discriminates patients with and without increased TRV with 100% accuracy. This finding was then validated in a cohort of patients with SCD without (n = 10) and with pulmonary hypertension (n = 10, 90% accuracy). Increased TRV-related miRNAs revealed strong in silico binding predictions of miR-301a to GALNT13 corroborated by microarray analyses demonstrating an inverse correlation between their expression. A genetic association study comparing patients with an elevated (n = 49) versus normal (n = 63) TRV revealed five significant single-nucleotide polymorphisms within GALNT13 (P < 0.005), four trans-acting (P < 2.1 × 10(-7)) and one cis-acting (P = 0.6 × 10(-4)) expression quantitative trait locus upstream of the adenosine-A2B receptor gene (ADORA2B). CONCLUSIONS: These studies validate the clinical usefulness of genomic signatures as potential biomarkers and highlight ADORA2B and GALNT13 as potential candidate genes in SCD-associated elevated TRV.


Subject(s)
Anemia, Sickle Cell/genetics , Anemia, Sickle Cell/physiopathology , N-Acetylgalactosaminyltransferases/genetics , Receptor, Adenosine A2B/genetics , Tricuspid Valve Insufficiency/genetics , Tricuspid Valve Insufficiency/physiopathology , Adult , Anemia, Sickle Cell/diagnostic imaging , Cardiac Catheterization , Cohort Studies , Echocardiography, Doppler/methods , Female , Gene Expression Profiling/methods , Genetic Markers/genetics , Genome-Wide Association Study/methods , Humans , Hypertension, Pulmonary/diagnostic imaging , Hypertension, Pulmonary/genetics , Hypertension, Pulmonary/physiopathology , Male , Microarray Analysis/methods , Polymorphism, Single Nucleotide/genetics , Pulmonary Artery/diagnostic imaging , Pulmonary Artery/physiopathology , Reproducibility of Results , Support Vector Machine , Tricuspid Valve Insufficiency/diagnostic imaging , Polypeptide N-acetylgalactosaminyltransferase
5.
Echocardiography ; 29(8): 962-9, 2012 Sep.
Article in English | MEDLINE | ID: mdl-22563937

ABSTRACT

BACKGROUND: Sickle cell disease (SCD) is a hemoglobinopathy that affects one in 500 African Americans. Although it is well established that patients with SCD have left ventricular (LV) diastolic dysfunction, it is not clear whether they have subtle LV systolic dysfunction despite preserved ejection fraction (EF). We used three-dimensional speckle tracking echocardiography (3DSTE) to assess changes in both systolic and diastolic LV function in SCD. METHODS: Transthoracic real time 3D images were obtained (Philips iE33) in 56 subjects, including 28 stable outpatients with SCD (age 33 ± 7 years) and 28 normal controls (age 35 ± 9 years). 3DSTE was performed using prototype software (4DLV Analysis, TomTec) to obtain LV volume and deformation time curves, from which indices of systolic and diastolic LV function were calculated. RESULTS: In SCD patients, 3DSTE-derived LV filling parameters were significantly different from normal controls, reflecting an increase in both rapid and atrial filling volumes and prolonged active relaxation, depicted by a decrease in filling volume fractions at fixed times and an increase in rapid filling duration. Global LV systolic function was not only preserved but increased compared to controls, as reflected by significantly increased global longitudinal strain. Importantly, twist angle and torsion as well as radial and circumferential components of 3D strain were similar in both groups. CONCLUSIONS: 3DSTE was able to confirm diastolic dysfunction, as expected in some patients with SCD. However, 3DSTE strain analysis did not reveal any changes in LV systolic function. These findings provide novel insight into the pathophysiology of the cardiovascular complications of SCD.


Subject(s)
Anemia, Sickle Cell/diagnostic imaging , Anemia, Sickle Cell/physiopathology , Echocardiography, Three-Dimensional/methods , Elasticity Imaging Techniques/methods , Ventricular Dysfunction, Left/diagnostic imaging , Ventricular Dysfunction, Left/physiopathology , Adult , Anemia, Sickle Cell/complications , Elastic Modulus , Female , Humans , Male , Reproducibility of Results , Sensitivity and Specificity , Stroke Volume , Ventricular Dysfunction, Left/etiology
6.
Echocardiography ; 29(1): 19-24, 2012.
Article in English | MEDLINE | ID: mdl-21967480

ABSTRACT

BACKGROUND: Assessment of right ventricular (RV) function is difficult due to the complex shape of this chamber. Tricuspid annular plane systolic excursion (TAPSE) measured with M-mode echocardiography is frequently used as an index of RV function. However, its accuracy may be limited by ultrasound beam misalignment. We hypothesized that two-dimensional (2D) speckle tracking echocardiography (STE) could provide more accurate estimates of RV function. Accordingly, STE was used to quantify tricuspid annular displacement (TAD), from which RV longitudinal shortening fraction (LSF) was calculated. These STE derived indices were compared side-by-side with M-mode TAPSE measurements against cardiac magnetic resonance (CMR) derived RV ejection fraction (EF). METHODS: Echocardiography (Philips iE33, four-chamber view) and CMR (Siemens, 1.5 T) were performed on the same day in 63 patients with a wide range of RV EF (23-70% by CMR). TAPSE was measured using M-mode echocardiography. TAD and RV LSF were obtained using STE analysis (QLAB CMQ, Philips). TAPSE, TAD and RV LSF values were compared with RV EF obtained from CMR short axis stacks. RESULTS: STE analysis required <15 seconds and was able to track tricuspid annular motion in all patients as verified visually. Correlation between RV EF and TAD (0.61 free-wall, 0.65 septal) was similar to that with M-mode TAPSE (0.63). However, STE-derived RV LSF showed a higher correlation with CMR EF (r = 0.78). CONCLUSION: RV LSF measurement by STE is fast and easy to obtain and provides more accurate evaluation of RV EF than the traditional M-mode TAPSE technique, when compared to CMR reference. (Echocardiography 2012;29:19-24).


Subject(s)
Echocardiography/methods , Elasticity Imaging Techniques/methods , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Imaging, Cine/methods , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/pathology , Ventricular Dysfunction, Right/diagnosis , Adult , Algorithms , Female , Humans , Image Enhancement/methods , Male , Reproducibility of Results , Sensitivity and Specificity
7.
J Am Soc Echocardiogr ; 25(1): 80-8, 2012 Jan.
Article in English | MEDLINE | ID: mdl-22000777

ABSTRACT

BACKGROUND: Left ventricular (LV) volumes and ejection fraction derived from two-dimensional echocardiography are two measures of adverse LV remodeling, which predict survival in patients with systolic heart failure. However, the geometric assumptions and image foreshortening that can occur with two-dimensional echocardiography reduces measurement accuracy and thus predictive value. By its nature, three-dimensional (3D) echocardiography allows the entire LV shape to be studied, providing a methodology to examine LV remodeling through LV curvature on a global and regional scale. The aim of this study was to correlate changes in global and regional LV shape to LV ejection fraction. METHODS: Full-volume, 3D transthoracic echocardiographic studies of the left ventricle were performed in 106 consecutive patients with either normal left ventricles (n = 59) or cardiomyopathies (n = 47). Customized software (QLAB) was used to extract segmented 3D LV endocardial shells at end-systole and end-diastole and to analyze these shells to determine global and regional LV shape analysis. Independent t tests were used for intergroup comparisons, and linear regression was used to correlate regional shape changes with systolic performance. RESULTS: Derivation and analysis of the 3D LV shells was possible in all patients. Patients with dilated cardiomyopathy had significantly smaller curvature values, indicating rounder global LV shape throughout the cardiac cycle. Regional analysis identified a loss of septal and apical curvatures in these patients. Systolic apical mean curvature was well correlated with LV ejection fraction (r = 0.89). CONCLUSIONS: This is the first study to demonstrate that regional remodeling measured by regional 3D LV curvature correlates well with LV function. As well, this methodology is independent of the geometric assumptions that limit the predictive value of two-dimensional echocardiographic measures of LV remodeling. Overall, this is a novel tool that may have applications in the assessment and prediction of outcomes of different forms of dilated cardiomyopathy.


Subject(s)
Echocardiography, Three-Dimensional/methods , Stroke Volume , Ventricular Dysfunction, Left/diagnostic imaging , Adult , Humans , Male , Middle Aged , Reproducibility of Results , Sensitivity and Specificity , Statistics as Topic , Ventricular Remodeling
8.
J Am Soc Echocardiogr ; 24(8): 860-7, 2011 Aug.
Article in English | MEDLINE | ID: mdl-21719254

ABSTRACT

BACKGROUND: Accurate segmental mitral valve (MV) analysis is essential for surgical planning. Although real-time three-dimensional (3D) transesophageal echocardiography has improved the ability to visualize the MV, accurate localization of MV pathology from 3D transesophageal echocardiographic images still remains experience dependent. Three-dimensional parametric maps of the MV obtained from these images further simplify the visualization of MV anatomy. The aims of this study were to examine whether 3D parametric maps of the MV could improve the diagnostic accuracy in localizing pathology and to determine their usefulness for readers with different levels of training. METHODS: Five novice (American Society of Echocardiography [ASE] level 2), three intermediate-level (ASE level 3; <500 MV cases), and two expert (ASE level 3; >500 MV cases) readers interpreted MV segmental anatomy in 50 patients (30 with degenerative MV disease, 20 with normal MVs). All readers reviewed two-dimensional and 3D transesophageal echocardiographic and 3D parametric maps at sequential weekly sessions. The results were compared with surgical findings. RESULTS: Expert readers were the most accurate irrespective of image type. Novice readers were the least accurate and commonly misinterpreted P2 and P3 scallops. Their accuracy was highest when interpreting 3D parametric maps (from 87% with two-dimensional transesophageal echocardiography to 92%). Intermediate readers' accuracy fell between the other two groups irrespective of image type and showed no change with the use of parametric maps. CONCLUSIONS: This is the first study to show that the interpretation of 3D parametric maps improves the accuracy of localization of MV pathology by novice readers. Therefore, parametric maps should be used routinely by less experienced readers during the assessment of degenerative MV disease.


Subject(s)
Echocardiography, Three-Dimensional , Image Processing, Computer-Assisted , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/pathology , Mitral Valve/diagnostic imaging , Mitral Valve/pathology , Adult , Aged , Echocardiography , Echocardiography, Three-Dimensional/methods , Female , Humans , Male , Middle Aged , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnosis , Mitral Valve Insufficiency/surgery , Predictive Value of Tests , Reproducibility of Results , Retrospective Studies , Sensitivity and Specificity
9.
J Cardiovasc Comput Tomogr ; 5(4): 247-54, 2011.
Article in English | MEDLINE | ID: mdl-21723516

ABSTRACT

BACKGROUND: The ability of multidetector computed tomography (MDCT) to detect stress-induced myocardial perfusion abnormalities is of great clinical interest as a potential tool for the combined evaluation of coronary stenosis and its significance. However, stress testing requires repeated scanning that is associated with additional radiation exposure and iodine contrast. OBJECTIVE: Our goal was to determine the effects of reduced tube voltage and contrast dose on the ability to detect perfusion abnormalities. METHODS: We studied 40 patients referred for coronary CT angiography (CTA) who agreed to undergo additional imaging after administration of an A(2A)-agonist (regadenoson 0.4 mg). Images were acquired at rest and during hyperemia with prospective gating with 120 kV tube voltage with 80-90 mL of contrast in 20 patients (group 1) and 100 kV with 55-70 mL of contrast in the remaining 20 patients (group 2). Custom 3D analysis software was used to define 3D myocardial segments and measure x-ray attenuation in each segment. In each group of patients, myocardial attenuation was averaged for segments supplied by coronary arteries with stenosis causing >50% luminal narrowing on coronary CTA and separately for segments supplied by arteries without significant stenosis. RESULTS: Coronary CTA detected stenosis >50% in 23 of 120 coronary arteries in 16 of 40 patients. In all patients combined, myocardial attenuation increased from 86 ± 9 at rest to 110 ± 17 HU with stress, reflecting an increase in tissue blood flow, despite the decrease in left ventricular cavity attenuation (347 ± 72 to 281 ± 55 HU), reflecting an increase in cardiac output. Importantly, in both groups, myocardial attenuation was equally reduced in segments supplied by diseased arteries (group 1: 119 ± 19 vs 103 ± 14 HU, P < 0.05; group 2: 108 ± 20 vs 97 ± 16 HU, P < 0.05), despite the 74% reduction in radiation (from 7.4 ± 2.8 to 1.9 ± 0.45 mSv) and the 28% reduction in contrast dose (from 84 ± 7 to 60 ±7 mL) (both P < 0.05). CONCLUSIONS: Regadenoson stress MDCT imaging can detect hypoperfused myocardium even when imaging settings are optimized to provide a significant reduction in radiation and contrast doses.


Subject(s)
Coronary Circulation , Coronary Stenosis/diagnostic imaging , Myocardial Perfusion Imaging/methods , Purines , Pyrazoles , Radiation Dosage , Tomography, X-Ray Computed , Vasodilator Agents , Adult , Aged , Contrast Media , Coronary Stenosis/physiopathology , Female , Humans , Hyperemia/diagnostic imaging , Hyperemia/physiopathology , Male , Middle Aged , Predictive Value of Tests , Prospective Studies , Radiographic Image Interpretation, Computer-Assisted , Severity of Illness Index
10.
J Am Soc Echocardiogr ; 24(8): 878-85, 2011 Aug.
Article in English | MEDLINE | ID: mdl-21645991

ABSTRACT

BACKGROUND: Myocardial deformation measurements using two-dimensional speckle-tracking echocardiography (STE) are known to vary among vendors. The intervendor agreement of three-dimensional (3D) deformation indices has not been studied. The goals of this study were to determine the intervendor agreement of 3D STE-based measurements of left ventricular (LV) deformation parameters to investigate the intrinsic variability of these measurements and identify the sources of intervendor differences. METHODS: Real-time full-volume images obtained in 30 subjects with normal LV systolic function using two vendors' equipment (V1 and V2) on the same day were analyzed by two independent observers using two software packages (S1 and S2). Agreement between three technique combinations (V1/S1, V2/S2, and V1/S2) and their intrinsic reproducibility (interobserver and intraobserver agreement) were assessed using intraclass correlation coefficients. Parameters of LV deformation included global longitudinal strain, twist, 3D displacement, and 3D strain and its radial, longitudinal, and circumferential components. RESULTS: For all three combinations, intertechnique agreement was poor (intraclass correlation coefficient < 0.4), always beyond the intrinsic variability. For all measured parameters, the intertechnique agreement was better when the same software package was used with images from different vendors (V2/S2 vs V1/S2) than when images from same vendor were analyzed using different software (V1/S2 vs V1/S1). CONCLUSIONS: Three-dimensional STE-derived LV deformation parameters are highly vendor dependent, and the discordance levels are beyond intrinsic measurement variability of any of the tested combinations of imaging equipment and analysis software. This intervendor discordance must be taken into account when interpreting 3D deformation data.


Subject(s)
Echocardiography, Three-Dimensional , Heart Ventricles/diagnostic imaging , Heart Ventricles/physiopathology , Ventricular Dysfunction, Left/diagnostic imaging , Ventricular Dysfunction, Left/physiopathology , Adult , Algorithms , Echocardiography, Three-Dimensional/methods , Female , Humans , Imaging, Three-Dimensional , Male , Observer Variation , Prospective Studies , Reproducibility of Results , Software
11.
J Am Soc Echocardiogr ; 23(5): 511-5, 2010 May.
Article in English | MEDLINE | ID: mdl-20356710

ABSTRACT

BACKGROUND: Left ventricular (LV) ejection fraction (EF) by transthoracic two-dimensional echocardiography is time-intensive and highly dependent on image quality. Mitral annular displacement (MAD) qualitatively correlates with EF and can be measured in patients with poor image quality and dropout. The authors hypothesized that speckle-tracking echocardiography (STE)-derived MAD could quantify EF accurately and tested this hypothesis using cardiac magnetic resonance (CMR) as a reference. METHODS: One hundred eighteen patients undergoing clinical transthoracic echocardiography were screened, and 110 whose mitral annuli was sufficiently well-defined irrespective of LV endocardial visualization underwent CMR within 6 days (85 of 110 in 1 day). Reference CMR EF values were obtained using standard methodology. STE was used to track annular motion throughout the cardiac cycle in the apical 2-chamber and 4-chamber views. To establish the relationship between MAD and CMR EF and to obtain a formula to estimate EF from MAD, regression analysis was performed in a study group of 60 patients with a wide range of EFs. This formula was then used in an independent test group of 50 patients by comparing estimated MAD EF against CMR EF values using Pearson's correlation and Bland-Altman analyses. RESULTS: In the study group, STE MAD correlated highly with CMR EF and resulted in a formula relating MAD to EF. In the test group, estimated EF correlated well with CMR EF (4-chamber, R(2) = 0.64; 2-chamber, R(2) = 0.55), with near-zero bias and acceptable limits of agreement. Intraobserver and interobserver variability were between 5.8% and 12.7%. CONCLUSIONS: STE MAD is a clinically useful tool for quick, easy, robust, and accurate estimates of EF irrespective of LV endocardial definition.


Subject(s)
Algorithms , Echocardiography/methods , Elasticity Imaging Techniques/methods , Image Interpretation, Computer-Assisted/methods , Mitral Valve/diagnostic imaging , Ventricular Dysfunction, Left/diagnostic imaging , Adult , Female , Humans , Image Enhancement/methods , Middle Aged , Motion , Reproducibility of Results , Sensitivity and Specificity
12.
Am Heart J ; 157(3): 556-62, 2009 Mar.
Article in English | MEDLINE | ID: mdl-19249428

ABSTRACT

BACKGROUND: Providing patients with documented discharge instructions is a performance measure of health care quality. It is not well known how often cardiac patients comply with the list of instructions or what their association is with health status outcomes after an acute myocardial infarction. METHODS: Acute myocardial infarction patients (N = 2,498) were prospectively enrolled into a 19-center study and asked, at 1 month, if they had recalled receiving instructions at discharge on any of the 13 secondary prevention behaviors (eg, exercise, medications, diet, and smoking). Adherence, defined as the percentage of relevant activities patients reported adhering to at 1 month, was grouped into 4 categories: poor (0%-49%), partial (50%-74%), careful (75%-99%), and very careful (100%). RESULTS: A total of 2,046 patients completed 1-month interviews and received instruction on at least 1 risk factor management (RFM) behavior. Very careful adherence at 1-month was reported most frequently with "taking medications as prescribed" (94%). In multivariable-adjusted models, patients who reported being poorly adherent were 58% more likely to report angina at 1 year as compared with those who very carefully followed RFM (relative risk 1.58, 95% CI 1.05-2.37). There was no independent association between RFM behavior and quality of life, physical functioning, rehospitalization, or mortality. CONCLUSIONS: There is substantial variation in the types of RFM to which acute myocardial infarction patients adhere. In aggregate, stronger adherence was associated with less angina at 1 year. More research is needed to understand adherence patterns and its association with outcomes.


Subject(s)
Health Behavior , Myocardial Infarction/epidemiology , Myocardial Infarction/therapy , Patient Compliance/statistics & numerical data , Aged , Female , Health Status Indicators , Humans , Male , Middle Aged , Patient Discharge , Risk Factors , Treatment Outcome
13.
Arch Intern Med ; 168(19): 2111-7, 2008 Oct 27.
Article in English | MEDLINE | ID: mdl-18955640

ABSTRACT

BACKGROUND: Recognizing the importance of smoking cessation after acute myocardial infarction (AMI), the Centers for Medicare & Medicaid Services and the Joint Commission on Accreditation of Healthcare Organizations currently uses documentation of smoking cessation counseling (SCC) as a metric of hospitals' quality of AMI care. Yet, the association between hospitals' performance of this quality measure and subsequent tobacco cessation rates has not been established. METHODS: We analyzed 889 consecutive smokers treated for AMI at 19 hospitals in PREMIER (Prospective Registry Evaluating Myocardial Infarction: Events and Recovery) between January 1, 2003, and June 28, 2004. Patients were followed up for 1 year after hospitalization. Multivariate regression modeling was performed to determine the association between hospital-level documented SCC rates and tobacco cessation rates after discharge. RESULTS: On a hospital level, the median medical record-documented SCC rate was 72.0% (interquartile range, 59.6%-90.1%). At 1 year, the median smoking cessation rate was 55.6% (interquartile range, 37.5%-61.9%). Although patients with documented SCC were more likely to recall receiving SCC at 1 month (86.1% vs 70.8%, P < .001), their rate of quitting at 1 year was lower than that of patients without documented SCC (50.1% vs 60.7%, P = .02; relative risk, 0.76; 95% confidence interval, 0.61-0.94). At the hospital level, there was no correlation between SCC documentation and successful quitting at 6 months (r = -0.19, P = .11) or 1 year (r = -0.13, P = .45). CONCLUSIONS: The performance metric for SCC, as it is currently structured, does not correlate with actual smoking cessation at 6 months or 1 year. Revision of this performance measure should be considered to more effectively reflect the goal of promoting smoking cessation.


Subject(s)
Directive Counseling/standards , Mental Recall , Myocardial Infarction/psychology , Outcome and Process Assessment, Health Care , Smoking Cessation/psychology , Directive Counseling/statistics & numerical data , Hospitals , Humans , Prospective Studies , Smoking Cessation/statistics & numerical data
14.
Implement Sci ; 3: 58, 2008 Dec 31.
Article in English | MEDLINE | ID: mdl-19117513

ABSTRACT

BACKGROUND: In the setting of coronary angiography, generic consent forms permit highly variable communication between patients and physicians. Even with the existence of multiple risk models, clinicians have been unable to readily access them and thus provide patients with vague estimations regarding risks of the procedure. METHODS: We created a web-based vehicle, PREDICT, for embedding patient-specific estimates of risk from validated multivariable models into individualized consent documents at the point-of-care. Beginning August 2006, outpatients undergoing coronary angiography at the Mid America Heart Institute received individualized consent documents generated by PREDICT. In February 2007 this approach was expanded to all patients undergoing coronary angiography within the four Kansas City hospitals of the Saint Luke's Health System. Qualitative research methods were used to identify the implementation challenges and successes with incorporating PREDICT-enhanced consent documents into routine clinical care from multiple perspectives: administration, information systems, nurses, physicians, and patients. RESULTS: Most clinicians found usefulness in the tool (providing clarity and educational value for patients) and satisfaction with the altered processes of care, although a few cardiologists cited delayed patient flow and excessive patient questions. The responses from administration and patients were uniformly positive. The key barrier was related to informatics. CONCLUSION: This preliminary experience suggests that successful change in clinical processes and organizational culture can be accomplished through multidisciplinary collaboration. A randomized trial of PREDICT consent, leveraging the accumulated knowledge from this first experience, is needed to further evaluate its impact on medical decision-making, patient compliance, and clinical outcomes.

15.
Circ Cardiovasc Qual Outcomes ; 1(1): 21-8, 2008 Sep.
Article in English | MEDLINE | ID: mdl-20031784

ABSTRACT

BACKGROUND: Standard consent forms result in highly variable communication between patients and physicians. To enhance the consent process and facilitate shared decision making, we developed a World Wide Web-based program, PREDICT (Patient Refined Expectations for Deciding Invasive Cardiac Treatments), to systematically embed patient-specific estimates of death, bleeding, and restenosis into individualized percutaneous coronary intervention informed consent documents. We then compared patients' experiences with informed consent before and after implementation of PREDICT. METHODS AND RESULTS: Between August 2006 and May 2007, patients undergoing nonemergent cardiac catheterization who received the original consent form (n=142) were interviewed and compared with those who received the PREDICT consent form (n=193). Hierarchical modified Poisson regression models were used to adjust for clustering of patients within physicians. Compared with the original consent group, those in the PREDICT group reported higher rates of reading the consent form (72% versus 44%, relative risk [RR] 1.64, 95% confidence interval [CI] 1.24 to 2.16), increased perception of shared decision making (67% versus 45%, RR 1.48, 95% CI 0.99 to 2.22), and decreased anxiety (35% versus 55%, RR 0.70, 95% CI 0.53 to 0.91). Although there were no differences between groups in patients' ability to name complications of percutaneous coronary intervention, among patients who identified either death or bleeding as a potential complication, more patients in the PREDICT group recalled being informed of their estimated risk of that complication (death: 85% versus 62%, RR 1.37, 95% CI 1.03 to 1.82; bleeding: 92% versus 71%, RR 1.28, 95% CI 1.06 to 1.56). CONCLUSIONS: In this preliminary, single-center experience, individualized consent forms with patient-specific risks were associated with improved participation in the consent process, reduced anxiety, and better risk recall. PREDICT is one potential strategy for improving the current practice of obtaining informed consent for percutaneous coronary intervention.


Subject(s)
Informed Consent , Mental Competency , Adult , Aged , Cardiac Catheterization , Decision Making , Evidence-Based Medicine , Female , Humans , Male , Middle Aged , Outcome Assessment, Health Care , Patient Education as Topic , Physician-Patient Relations
16.
Cancer Invest ; 24(3): 283-7, 2006.
Article in English | MEDLINE | ID: mdl-16809156

ABSTRACT

Pemetrexed is a multitargeted antifolate approved by the Food and Drug Administration for patients with mesothelioma and non small cell lung cancer. As this agent is almost exclusively cleared by renal excretion, trials leading to its approval were conducted in patients with normal renal function. However, this cycle active agent often is administered with cisplatin to patients who may have pleural effusions and ascites. As a result, the potential for drug accumulation in effusions and for accompanying renal insufficiency is real. Recommendations for the management of pemetrexed toxicity in the presence of renal failure have not been established. A case of treatment-related acute renal failure following chemotherapy with cisplatin and pemetrexed in a patient with advanced mesothelioma and ascites is presented. Pharmacologic studies in this patient revealed persistent pemetrexed levels in ascites and plasma. This is the first time that significant accumulation of pemetrexed in ascetic fluid has been reported in the literature. Treatment with leucovorin, folate, and continuous veno-venous hemodialysis was initiated. Thymidine and carboxypeptidase were not available. Dialysis was unsuccessful in removing pemetrexed. Theoretical and practical approaches to management of similar cases are presented.


Subject(s)
Acute Kidney Injury/chemically induced , Antineoplastic Combined Chemotherapy Protocols/adverse effects , Ascitic Fluid/chemistry , Glutamates/pharmacokinetics , Guanine/analogs & derivatives , Pleural Effusion/chemistry , Acute Kidney Injury/therapy , Antineoplastic Agents/adverse effects , Antineoplastic Agents/metabolism , Antineoplastic Combined Chemotherapy Protocols/metabolism , Cisplatin/adverse effects , Folic Acid/therapeutic use , Glutamates/adverse effects , Guanine/adverse effects , Guanine/pharmacokinetics , Humans , Leucovorin/therapeutic use , Male , Mesothelioma/drug therapy , Middle Aged , Pemetrexed , Pleural Neoplasms/drug therapy , Renal Dialysis , Vitamin B 12/therapeutic use , Vitamin B Complex/pharmacology
SELECTION OF CITATIONS
SEARCH DETAIL
...