Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Clin Lab Anal ; 37(23-24): e24992, 2023 Dec.
Article in English | MEDLINE | ID: mdl-38058281

ABSTRACT

BACKGROUND: Patients negative for the JAK2 p.V617F somatic variant are frequently reflexed to testing for MPL exon 10 variants. Detection of these variants via multiplexed allele-specific PCR followed by fragment analysis has been previously published. The present study builds on this concept by improving the detection of the p.W515A variant, adding a second allele-specific primer to detect the p.W515R variant, and incorporating an improved primer for p.S505N detection. METHODS: The W515 amplification employs 5'-labeled allele-specific forward primers to detect p.W515K, p.W515L, p.W515R, and p.W515A. The p.S505N amplification includes an allele-specific reverse primer with a tail extension. Fragments were subject to capillary electrophoresis on an ABI 3500 Genetic Analyzer and analyzed using GeneMapper 6.0 (Thermo Fisher Scientific). RESULTS: Thirty MPL-negative and 13 MPL-positive samples previously tested by a reference laboratory were tested with the MPL LDT. Results were 100% concordant. The MPL LDT has a limit of detection of at least 5% VAF for the p.W515 variants and 10% VAF for the p.S505N variant. CONCLUSION: Current MPL assays are predominantly focused on p.W515L/K and p.S505N mutations. We have engineered an MPL test for detecting p.W515A/L/K/R and p.S505N variants, thereby increasing the diagnostic yield with little additional expense or technician time.


Subject(s)
Myeloproliferative Disorders , Neoplasms , Humans , Neoplasms/genetics , Myeloproliferative Disorders/diagnosis , Myeloproliferative Disorders/genetics , Mutation/genetics , Exons , Codon , Janus Kinase 2/genetics , Receptors, Thrombopoietin/genetics
2.
J Mol Diagn ; 24(4): 294-308, 2022 04.
Article in English | MEDLINE | ID: mdl-35124239

ABSTRACT

Following the outbreak and subsequent pandemic of coronavirus disease 2019 (COVID-19), clinical diagnostic laboratories worldwide sought accurate and reliable testing methodologies. However, many laboratories were and still are hindered by a number of factors, including an unprecedented demand for testing, reagent and laboratory supply shortages and availability of qualified staff. To respond to these concerns, two separate laboratory-developed tests were validated for detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) using two different specimen types. In addition, these assays target different genomic regions of SARS-CoV-2, allowing for viral detection and mitigating genetic variation. Lower limit of detection and clinical evaluation studies showed detection of SARS-CoV-2 at 500 cp/mL with nasopharyngeal and saliva samples. These multiplexed RT-qPCR assays, although based on modified CDC, New York State Department of Health, and World Health Organization Emergency Use Authorization tests, allow for higher throughput and rapid turnaround time, benefiting patients, clinicians, and communities as a whole. These cost-effective tests also use readily obtainable reagents, circumventing commercial assay supply chain issues. The laboratory-developed tests described here have improved patient care and are highly adaptable should the need arise at other clinical diagnostic laboratories. Furthermore, the foundation and design of these assays may be modified in the future for detection of COVID-19 variants or other RNA-based viral detection tests.


Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnosis , Genomics , Humans , RNA, Viral/analysis , RNA, Viral/genetics , SARS-CoV-2/genetics , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...