Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 84
Filter
1.
J Clin Med ; 12(19)2023 Sep 30.
Article in English | MEDLINE | ID: mdl-37834958

ABSTRACT

BACKGROUND: Atrial fibrillation (AF) is a common cardiac rhythm disorder associated with hemodynamic disruptions and thromboembolic events. While antiarrhythmic drugs are often recommended as the initial treatment, catheter ablation has emerged as a viable alternative. However, the recurrence of AF following ablation remains a challenge, and there is growing interest in exploring inflammatory markers as predictors of recurrence. METHODS: This retrospective, cross-sectional analysis included 249 patients who underwent cryoablation for paroxysmal AF. The relationship between the 'C-reactive protein (CRP) to albumin ratio (CAR)' and AF recurrence was examined. RESULTS: Two hundred and forty-nine patients with paroxysmal non-valvular atrial fibrillation were included. They were divided into two groups: those without recurrence (Group 1) and those with recurrence (Group 2). Significant differences were observed in age (57.2 ± 9.9 vs. 62.5 ± 8.4, p = 0.001) and left atrial size (4.0 ± 0.5 vs. 4.2 ± 0.7, p = 0.001) between the two groups. In blood parameters, significant differences were found in CRP (5.2 ± 1.3 vs. 9.4 ± 2.8, p < 0.001) and neutrophil counts (5.1 ± 2.2 vs. 6.7 ± 3.6, p = 0.001). In univariate regression analysis, age (OR: 1.058, CI: 1.024-1.093, p = 0.001), WBC count (OR: 1.201, CI: 1.092-1.322, p < 0.001), neutrophil count (OR: 1.239, CI: 1.114-1.378, p = 0.001), CAR (OR: 1.409, CI: 1.183-1.678, p < 0.001), and left atrial diameter (OR: 0.968, CI: 0.948-0.989, p = 0.002) showed significant associations with AF recurrence. CONCLUSIONS: Inflammation plays a crucial role in the initiation and progression of AF. This study demonstrated that along with age, the CAR can serve as an independent predictor of AF recurrence following cryoablation.

2.
3.
Kardiologiia ; 63(5): 47-52, 2023 May 31.
Article in Russian | MEDLINE | ID: mdl-37307208

ABSTRACT

Aim    The aim of this study was to determine the average minimum number of slow pathway ablation procedures required to reach a steady success rate among inexperienced operators.Material and Methods    We analyzed the consecutive AVNRT ablation procedures of three inexperienced operators for the rate of operational success and complications.Results    Operators performed a total of 156 AVNRT ablation procedures. There was no statistical significance between the three operators regarding the rate of success (p=0.69) and complications. There were significant differences between the operators in terms of procedure time, fluoroscopy time, and cumulative air kerma. The variability of procedure time and cumulative air kerma, both among three operators and within each operator, decreased significantly after the 25th case. Each operator was analyzed individually for the probability of success as related to the cumulative number of ablations. All trainee operators reached a success rate of 90 % at the 27th procedure.Conclusion    An average of 27 slow pathway ablation procedures should be performed by a beginner operator to achieve proficiency.


Subject(s)
Radiofrequency Ablation , Tachycardia, Atrioventricular Nodal Reentry , Humans , Learning Curve , Bundle of His , Probability
4.
Anatol J Cardiol ; 27(10): 567-572, 2023 09 30.
Article in English | MEDLINE | ID: mdl-37329114

ABSTRACT

BACKGROUND: Several clinical trials have assessed predictors for atrial fibrillation recurrence following cryoballoon catheter ablation. With these predictors, a practical and new scoring system can be developed to evaluate atrial fibrillation recurrence. The present study aimed to analyze the predictive value of the age, creatinine, and ejection fraction-left atrium score for potential recurrence of atrial fibrillation following cryoballoon catheter ablation in patients with symptomatic paroxysmal or persistent atrial fibrillation. METHODS: We retrospectively analyzed records of patients undergoing cryoballoon cath-eter ablation. atrial fibrillation recurrence was defined as an emerging atrial fibrillation episode around 12-month follow-up (with the exclusion of a 3-month blanking period). Univariate and multivariate analyses were performed to assess predictors of atrial fibrillation recurrence. In addition, receiver operating characteristic analysis was harnessed to evaluate the performance of the age, creatinine, and ejection fraction, left atrium score in determining the risk of atrial fibrillation recurrence. RESULTS: The study population comprised 106 subjects (age 52 ± 13 years, 63.2% women) with paroxysmal (84.9%, n = 90) or persistent (15.1%, n = 16) atrial fibrillation. age, creatinine, and ejection fraction, left atrium score was significantly higher in subjects with atrial fibrillation recurrence in comparison to those with the maintenance of sinus rhythm. However, on multivariate logistic regression analysis, only the age, creatinine, and ejection fraction, left atrium score (OR = 12.93, 95% CI: 2.22-75.21, P =.004) served as an independent predictor of atrial fibrillation recurrence following cryoballoon catheter ablation. CONCLUSION: Age, creatinine, and ejection fraction, left atrium score had an independent association with the risk of atrial fibrillation recurrence in subjects with atrial fibrillation undergoing cryoballoon catheter ablation. Therefore, this score might potentially serve as a useful tool for risk stratification of patients with atrial fibrillation.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Humans , Female , Adult , Middle Aged , Aged , Male , Creatinine , Retrospective Studies , Stroke Volume , Cryosurgery/adverse effects , Heart Atria , Catheter Ablation/adverse effects , Treatment Outcome , Recurrence
5.
Pacing Clin Electrophysiol ; 46(2): 185-189, 2023 02.
Article in English | MEDLINE | ID: mdl-36063407

ABSTRACT

The presence of mechanical heart valves in both aortic and mitral positions is a significant limitation for traditional left ventricular (LV) access, including retrograde transaortic and/or antegrade interatrial transseptal routes. We present a case of successful catheter ablation for ventricular tachycardia via a traditional transfemoral venous approach, which involves direct puncture of the inferior and medial aspect of the right atrium adjacent to the posteroseptal process of LV (PSPLV). Percutaneous trans-right atrial access to the left ventricle appears to be a safe and feasible method for catheter ablation of ventricular tachycardia in patients with mechanical aortic and mitral valves.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Tachycardia, Ventricular , Humans , Heart Ventricles/surgery , Mitral Valve/surgery , Atrial Fibrillation/surgery , Tachycardia, Ventricular/surgery , Heart Atria , Catheter Ablation/methods
6.
Int J Cardiol Heart Vasc ; 39: 100989, 2022 Apr.
Article in English | MEDLINE | ID: mdl-35257027

ABSTRACT

Background and Aim: Despite the advances in oral anticoagulation with NOACs, careful patient and dose selection is required with NOAC therapy. Our study aimed to assess treatment patterns of NOACs in AF along with patients' continuity to NOAC treatments in first year, and their knowledge level of AF and NOAC treatment. Methods: ASPECT-NOAC was designed as an observational, prospective, and multicenter study. AF patients who were prescribed NOACs within last four months were recruited from 34 outpatient cardiology clinics covering all geographic regions of Turkey. Baseline data were collected initially whereas patient awareness was evaluated at 3 to 4 weeks. Final study visit was performed at 12 months. Results: In total, 991 patients were included to the study. Mean ± standard deviation of age was 69.4 ± 10.2 years and 53.0% of patients were female. Mean duration from AF diagnosis was 24.9 ± 50.9 months. Mean CHA2DS2-VASc and HAS-BLED scores were 3.1 ± 1.5 and 1.6 ± 1.1, respectively. AF disease and NOAC treatment knowledge levels were found to be 48.9 ± 23.1% and 73.0 ± 19.3%, respectively. Among reduced dose users 71.4% of patients were prescribed inappropriate reduced doses. Through the study follow-up, 32 patients (3.2%) deceased and NOAC therapy was discontinued in 74 patients (8.7%). Conclusion: AF patients who recently started NOAC treatment in Turkey were found to have variable knowledge about their disease and anticoagulation treatment. It was observed that most of the patients continued the NOAC treatment throughout the study. Reduced dosing of NOACs was common, which was associated with higher baseline risk for bleeding as well as stroke.

8.
Coron Artery Dis ; 31(1): e27-e36, 2022 01 01.
Article in English | MEDLINE | ID: mdl-34010185

ABSTRACT

BACKGROUND: Congenital coronary artery anomalies (CCAAs) have the potential for life-threatening complications, including malignant ventricular arrhythmias and sudden cardiac death (SCD). In this study, we aimed to evaluate the relationship between impaired repolarization parameters and poor cardiovascular clinical outcomes in patients with potentially serious CCAAs. METHODS: This retrospective study included 85 potentially serious CCAA patients (mean age: 54.7 ± 13.6 years; male:44) who were diagnosed with conventional and coronary computed tomography angiography (CCTA). All patients underwent transthoracic echocardiography and 12-lead surface electrocardiography. Cardiac events were defined as sustained ventricular tachycardia or fibrillation, syncope, cardiac arrest and SCD. RESULTS: The presence of interarterial course (IAC) was confirmed by CCTA in 37 (43.5%) patients. During a median follow-up time of 24 (18-50) months, a total of 11 (12.9%) patients experienced cardiac events. The presence of IAC was significantly more frequent and Tp-e interval, Tp-e/QTc ratio and frontal QRS/T angle (fQRSTa) were significantly greater in patients with poor clinical outcomes. Moreover, the presence of IAC, high Tp-e/QTc ratio and high fQRSTa were found to be independent predictors of poor clinical outcomes and decreased long-term cardiac event-free survival in these patients. A net reclassification index was +1.0 for the Tp-e/QTc ratio and +1.3 for fQRSTa which were confirmable for additional predictability of these repolarization abnormalities. CONCLUSION: Impaired repolarization parameters, including wider fQRSTa, prolonged Tp-e interval, and increased Tp-e/QTc ratio, and IAC may be associated with poor cardiovascular clinical outcomes in potentially serious CCAA patients.


Subject(s)
Arrhythmias, Cardiac/complications , Coronary Vessels/physiopathology , Outcome Assessment, Health Care/statistics & numerical data , Adult , Aged , Arrhythmias, Cardiac/epidemiology , Arrhythmias, Cardiac/mortality , Echocardiography/methods , Echocardiography/statistics & numerical data , Electrocardiography/methods , Electrocardiography/statistics & numerical data , Female , Humans , Male , Middle Aged , Outcome Assessment, Health Care/methods , Retrospective Studies , Risk Factors
10.
J Electrocardiol ; 70: 50-55, 2022.
Article in English | MEDLINE | ID: mdl-34922221

ABSTRACT

BACKGROUND: The aim of the present study is to investigate the possible factors that might be predictive of effective antiarrhythmic effect of beta-blockers on premature ventricular complexes (PVC). METHODS: Data of 190 eligible consecutive patients to whom beta-blocker therapy had been initiated for treatment of PVC's were retrospectively evaluated. The Holter recording acquired before beta-blocker initiation and the first Holter acquired after beta blocker initiation during follow up was comprehensively evaluated for each patient. Parameters obtained from pre- and post-beta-blocker 24 h Holter recordings were compared with each other and possible predictors were evaluated for positive response to beta-blocker therapy. RESULTS: Sixty-one patients (32.1%) were observed to respond beta-blocker therapy with at least 50% reduction of daily PVC burden. Patients who responded to beta-blockers had significantly higher ratio of patients who had positive correlation between hourly heart rate and corresponding hourly PVC number (fast HR-PVC status) compared with non-responders (73.8% vs 48.1%, p < 0.001). Binary logistic regression analysis revealed PVC QRS width (Odds ratio: 0.971; p: 0.037) and fast HR-PVC status (Odds ratio: 2.935; p: 0.007) as the independent predictors of positive response to beta-blockers for treatment of PVC. CONCLUSION: Positive correlation between hourly heart rate and PVC incidence was found to be independent positive predictor and PVC QRS width was found to be independent negative predictor of beta-blocker success in our study. This observation might have important clinical implications to guide medical treatment of PVCs in clinical practice.


Subject(s)
Catheter Ablation , Ventricular Premature Complexes , Adrenergic beta-Antagonists/therapeutic use , Electrocardiography , Electrocardiography, Ambulatory , Humans , Retrospective Studies
11.
J Cardiovasc Electrophysiol ; 33(1): 117-122, 2022 01.
Article in English | MEDLINE | ID: mdl-34674347

ABSTRACT

INTRODUCTION: Single-center observational studies have shown promising results with fragmented electrogram (FE)-guided ganglionated plexus (GP) ablation in patients with vagally mediated bradyarrhythmia (VMB). We aimed to compare the acute procedural characteristics during FE-guided GP ablation in patients with VMB performed by first-time operators and those of a single high-volume operator. METHODS AND RESULTS: This international multicenter cohort study included data collected over 2 years from 16 cardiac hospitals. The primary operators were classified according to their prior GP ablation experience: a single high-volume operator who had performed > 50 GP ablation procedures (Group 1), and operators performing their first GP ablation cases (Group 2). Acute procedural characteristics and syncope recurrence were compared between groups. Forty-seven consecutive patients with VMB who underwent FE-guided GP ablation were enrolled, n = 31 in Group 1 and n = 16 in Group 2. The mean number of ablation points in each GP was comparable between groups. The ratio of positive vagal response during ablation on the left superior GP was higher in Group 1 (90.3% vs. 62.5%, p = .022). Ablation of the right superior GP increased heart rate acutely without any vagal response in 45 (95.7%) cases. The procedure time was longer in group 2 (83.4 ± 21 vs. 118.0 ± 21 min, respectively, p < .001). Over a mean follow-up duration of 8.0 ± 3 months (range 2-24 months), none of the patients suffered from syncope. CONCLUSION: This multi-center pilot study shows for the first time the feasibility of FE-guided GP ablation across a large group of procedure-naïve operators.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Atrial Fibrillation/surgery , Bradycardia/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods , Cohort Studies , Humans , Pilot Projects , Treatment Outcome , Vagus Nerve/surgery
12.
Anatol J Cardiol ; 25(7): 468-475, 2021 07.
Article in English | MEDLINE | ID: mdl-34236321

ABSTRACT

OBJECTIVE: This study aimed to evaluate the acute effect of cryoballoon ablation (CB-A) on electrocardiographic parameters that have been suggested to reflect heterogeneity in atrial conduction and ventricular repolarization. METHODS: A total of 67 patients (52.6±13.2 years, 43 men) without any exclusion criteria who had undergone CB-A for atrial fibrillation (AF) between January 01, 2015, and December 31, 2018, constituted our study population. Electrographic recordings obtained before and after the ablation procedure on the same day were retrospectively evaluated for the P-wave dispersion, QTc dispersion, Tp-Te interval, and Tp-Te/QT ratio. The pre- and post-ablation values were tested for significant differences. The association of the possible CB-A-related changes in these parameters with AF recurrence during follow-up was evaluated. RESULTS: P dispersion (30.1±6.8 vs. 35.9±9.4 ms, p<0.001), QT dispersion (20.7±7.5 vs. 24.0±8.8 ms, p<0.001), Tp-Te duration (on V5 83.6±8.1 vs. 110.2±9.5 ms, p<0.001), and Tp-Te/QT ratio (on V5 0.22±0.03 vs. 0.28±0.02, p<0.001) were observed to increase significantly after CB-A. There was no association between the magnitudes of change in any parameter and AF recurrence. CONCLUSION: CB-A had significant effects on electrocardiographic parameters related to atrial conduction and ventricular repolarization in the acute phase after CB-A. Further prospective studies are required to examine the time-related course of these alterations and their impact on clinical outcomes.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Atrial Fibrillation/surgery , Electrocardiography , Humans , Male , Pulmonary Veins/surgery , Recurrence , Retrospective Studies , Treatment Outcome
13.
Herz ; 46(5): 476-481, 2021 Oct.
Article in English | MEDLINE | ID: mdl-33464357

ABSTRACT

BACKGROUND: The aim of the present study was to determine the predictors of adequate intraprocedural premature ventricular complex (PVC) frequency for successful mapping and ablation of idiopathic PVCs. METHODS: A total of 101 consecutive patients (45 men; age: 47.9 ± 14.2 years) who had undergone idiopathic PVC ablation between 01 November 2018 and 24 June 2020 constituted our study population. Clinical and demographic data, procedural details and 24 h rhythm recordings that had been recorded before the procedure were retrospectively evaluated. Total PVC burden and diurnal variability assessed by the ratio of night time (22:00-06:00) over day time (06:00-22:00) PVC burden was calculated. The relationship between hourly PVC number and heart rate was also evaluated for each patient. Clinical characteristics and Holter parameters were compared between groups with and without adequate intraprocedural frequency of PVCs that permitted activation mapping. RESULTS: In all, 27 patients (26.7%) had infrequent intraprocedural PVCs which necessitated isoproterenol infusion or cancellation of ablation procedure due to inability of activation mapping. PVC burden was significantly higher in the group with frequent intraprocedural PVCs (26.1 ± 9.4% vs 21.2 ± 10.3%; p: 0.026). There were no significant differences between groups regarding the relationship between hourly PVC number and heart rate or the ratio of night/day PVC burden. Binary logistic regression analysis revealed the 24 h Holter PVC burden as the sole parameter that is significant predictor of frequent intraprocedural PVCs permitting activation mapping. CONCLUSION: The 24 h PVC burden was the only predictor of adequate intraprocedural PVC frequency permitting activation mapping during idiopathic PVC ablation.


Subject(s)
Catheter Ablation , Ventricular Premature Complexes , Adult , Heart Rate , Humans , Male , Middle Aged , Retrospective Studies , Ventricular Premature Complexes/diagnosis , Ventricular Premature Complexes/surgery
14.
Acta Cardiol ; 76(2): 127-131, 2021 Apr.
Article in English | MEDLINE | ID: mdl-32406298

ABSTRACT

BACKGROUND: There is limited data regarding the effect of idiopathic premature ventricular complexes (PVC) on myocardial repolarisation. Most of PVC's originate from right and left ventricular outflow tracts (RVOT and LVOT). AIM: The aim of this study is to evaluate the acute effect of outflow tract PVC ablation on electrocardiographic repolarisation markers. METHODS: A total of 180 patients (49.2 ± 13.6 years, 74 male) without any exclusion criteria who had undergone outflow tract PVC ablation between 1 January 2015 and 1 November 2018 constituted our study population. Electrocardiographic recordings that had been obtained before and after ablation procedure on the same day were retrospectively evaluated for the QTc dispersion, Tp-e interval, Tp-e/QT ratio and Tp-e/QTc ratio. Significance of difference between pre- and postablation values was tested. RESULTS: There was no significant difference regarding QTc dispersion between pre- and post-ablation state (36.5 ± 20.9 vs. 35.3 ± 16.4 ms, p: NS). However, Tp-e and Tp-e/QT values in all lateral precordial derivations were observed to decrease significantly after PVC ablation (in the respective order on derivation V5: 104.0 ± 21.6 ms vs. 91.1 ± 14.8 ms, p<.001 and 0.26 ± 0.05 vs. 0.23 ± 0.04, p<.001). CONCLUSIONS: Based on these observations, it may be suggested that frequent outflow tract PVC's increase transmural dispersion of repolarisation and this effect is attenuated by catheter ablation in the acute phase. Results of further prospective studies are required for evaluation of the long term effects of PVC ablation on myocardial repolarisation.


Subject(s)
Catheter Ablation , Ventricular Premature Complexes , Adult , Electrocardiography , Female , Heart Ventricles/diagnostic imaging , Heart Ventricles/surgery , Humans , Male , Middle Aged , Retrospective Studies , Ventricular Premature Complexes/diagnosis , Ventricular Premature Complexes/surgery
15.
Acta Cardiol ; 76(6): 605-610, 2021 Aug.
Article in English | MEDLINE | ID: mdl-32284019

ABSTRACT

BACKGROUND: The aim of present study is to evaluate the predictive value of QTc dispersion, Tp-Te interval and Tp-Te/QT ratio for idiopathic monomorphic outflow tract ventricular tachycardia (VT) occurrence in patients with frequent idiopathic outflow tract premature ventricular complexes (PVCs). METHODS: A total of 180 patients (49.2 ± 13.6 years, 74 male) who had undergone outflow tract PVC ablation between 01 January 2015 and 01 November 2018 constituted our study population. Patients with isolated outflow tract PVC without any VT recording on Holter recordings and without any inducible VT at EPS were classified as isolated PVC group. Patients with any episode of VT that has the same morphology with outflow tract PVC were classified as nonsustained or sustained VT groups based on the duration of VT episode. QTc dispersion, Tp-Te and Tp-Te/QT ratio values were calculated and compared between groups. RESULTS: There were 116 patients with isolated PVC, 35 patients with nonsustained VT and 29 patients with sustained VT. QTc dispersion, Tp-Te and Tp-Te/QT ratio values were significantly lower in patients with isolated PVC compared to patients with nonsustained or sustained VT episodes. Tpeak to Tend interval greater than 110.5 msec on derivation V6 predicted VT occurrence with 93.8% sensitivity and 82.8% specificity. Tpeak to Tend/QT interval greater than 0.27 on derivation V6 predicted VT occurrence with 93.8% sensitivity and 0.81% specificity. CONCLUSION: Tp-Te interval and Tp-Te/QT ratio on derivation V6 may aid in prediction of presence of outflow tract VT in clinical practice.


Subject(s)
Tachycardia, Ventricular , Ventricular Premature Complexes , Electrocardiography , Humans , Male , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/etiology , Ventricular Premature Complexes/complications , Ventricular Premature Complexes/diagnosis
16.
Herz ; 46(1): 82-88, 2021 Feb.
Article in English | MEDLINE | ID: mdl-33009623

ABSTRACT

BACKGROUND: The growing problem of endocardial lead infections and lead malfunctions has increased interest in percutaneous lead-removal technology. Transvenous lead extraction (TLE) via simple manual traction (SMT) is the first-line therapy. When SMT is not successful, TLE from the femoral vein using a gooseneck snare (GS) with a radiofrequency ablation catheter (RFAC) may be an alternative option. The aim of our study was to evaluate the success rate of transvenous extraction of chronically implanted leads via the femoral approach using a GS with RFCA in cases of failure with SMT. METHODS: The study included 94 consecutive patients who were referred for lead extraction due to pocket erosion and infection (71 patients) and to lead malfunction (23 patients). Initially, SMT was attempted for all patients. If SMT was not successful, patients underwent TLE using a GS with RFAC. RESULTS: Leads were extracted successfully with SMT in 34 patients (54 leads), while 60 patients (83 leads) underwent TLE using a GS with RFAC. The mean indwelling time of the leads was longer in the femoral approach with GS (87.5 ± 37.9 vs. 31.3 ± 25.8 months; p < 0.001). The procedural success rate was 96.7% in the femoral approach with GS. A preceding implantation lead duration of >51 months predicted an unsuccessful SMT necessitating alternative TLE using a GS with RFAC with 86% sensitivity and 78% specificity (p < 0.001). CONCLUSION: Transvenous lead extraction via the femoral approach using GS with RFAC may be an alternative approach to SMT with a high success rate, especially when the indwelling time of the leads is long.


Subject(s)
Defibrillators, Implantable , Pacemaker, Artificial , Defibrillators, Implantable/adverse effects , Device Removal , Femoral Artery , Humans , Retrospective Studies , Treatment Outcome
17.
Acta Cardiol ; 76(3): 236-242, 2021 May.
Article in English | MEDLINE | ID: mdl-33131407

ABSTRACT

OBJECTIVES: Patients and medical staff expose to significant radiation during electro-physiological (EP) procedures. There are few data regarding the leading factors of longer fluoroscopy time and higher scattered radiation in a laboratory giving EP training during those interventions. MATERIAL AND METHODS: The patients' recordings that underwent EP procedure in a single centre arrhythmia unit from February 2019 to January 2020 were examined. Prospectively collected data regarding procedure duration, fluoroscopy time and total air kerma, demographic characteristics of the patients, type of procedure, success of ablation and the use of electro anatomic mapping were retrospectively evaluated. Predictors of total air kerma were analysed with linear regression analysis. RESULTS: Study population consisted of 437 patients with a median age of 47 (39-56); 184 (42.1%) were male. Median fluoroscopy time was 768 (420-1320) seconds and median cumulative air kerma was 369 (191-750) mGy. Fluoroscopy time and cumulative air kerma were significantly lower in diagnostic EP studies compared to other procedures. There was no difference in terms of total air kerma between the procedures other than the diagnostic EP study. In multivariable linear regression analysis; body surface area, fluoroscopy time, not using the electro-anatomical mapping, unsuccessful ablation and atrial flutter ablation were predictors of total air kerma in EP studies performed by trainees. CONCLUSION: Scattered radiation during EP procedures performed by in-training operators is related with some factors. Awareness about those may help to effort reducing the harmful effect of ionising radiation.


Subject(s)
Electrophysiology , Fluoroscopy , Laboratories , Humans , Male , Radiation Dosage , Retrospective Studies
18.
J Electrocardiol ; 61: 71-76, 2020.
Article in English | MEDLINE | ID: mdl-32554159

ABSTRACT

OBJECTIVES: Data is scarce regarding the relation between P wave indices and new onset atrial fibrillation (NOAF) after trans-catheter aortic valve replacement (TAVR). AIMS: The present study aimed to find out certain characteristics of P wave that may predict NOAF after TAVR procedure. METHOD: Patients with severe calcific aortic stenosis who had undergone TAVR procedure between 2013 and 2019 in two centers were investigated. P wave abnormalities that have been resumed to reflect impaired atrial conduction; partial and advanced inter atrial block (IAB), P-wave terminal force in lead V1, P wave dispersion, reduced amplitude of P- wave in lead I, P wave peak time in D2 and V1 were evaluated on pre- procedural 12 derivation surface electrocardiography (ECG). The relationship between these parameters and incidence of NOAF during index hospitalization was evaluated. RESULTS: A total of 227 consecutive patients (median age 79 [74-83]; 134 [59%] female) were included in the study. NOAF occurred in 46 (20.3%) patients. P wave duration, P wave dispersion, number of patients with partial and advanced IAB, left atrium diameter, STS score were higher in NOAF patients. Use of general anesthesia and history of prior open heart surgery were also more frequent in NOAF group. In multivariable logistic regression analysis; advanced IAB (OR 6.413 [2.555-16.095] p < 0.01), P wave dispersion (OR 3.544 [1.431-8.780] p = 0.006) and use of general anesthesia (OR 2.736 [1.225-6.109] p = 0.014) were independent predictors of NOAF. CONCLUSION: Among P wave abnormalities evaluated on pre-procedural 12-derivation surface ECG, advanced IAB and P wave dispersion may predict NOAF after TAVR procedure.


Subject(s)
Aortic Valve Stenosis , Atrial Fibrillation , Transcatheter Aortic Valve Replacement , Aged , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Atrial Fibrillation/diagnosis , Catheters , Electrocardiography , Female , Humans , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects
19.
Turk Kardiyol Dern Ars ; 48(3): 289-303, 2020 04.
Article in English | MEDLINE | ID: mdl-32281950

ABSTRACT

OBJECTIVE: The evolution of non-vitamin K antagonist anticoagulants (NOACs) has changed the horizon of stroke prevention in atrial fibrillation (SPAF). All 4 NOACs have been tested against dose-adjusted warfarin in well-designed, pivotal, phase III, randomized, controlled trials (RCTs) and were approved by regulatory authorities for an SPAF indication. However, as traditional RCTs, these trials have important weaknesses, largely related to their complex structure and patient participation, which was limited by strict inclusion and extensive exclusion criteria. In the real world, however, clinicians are often faced with complex, multimorbid patients who are underrepresented in these RCTs. This article is based on a meeting report authored by 12 scientists studying atrial fibrillation (AF) in diverse ways who discussed the management of challenging AF cases that are underrepresented in pivotal NOAC trials. METHODS: An advisory board panel was convened to confer on management strategies for challenging AF cases. The article is derived from a summary of case presentations and the collaborative discussions at the meeting. CONCLUSION: This expert consensus of cardiologists aimed to define management strategies for challenging cases with patients who underrepresented in pivotal trials using case examples from their routine practice. Although strong evidence is lacking, exploratory subgroup analysis of phase III pivotal trials partially informs the management of these patients. Clinical trials with higher external validity are needed to clarify areas of uncertainty. The lack of clear evidence about complex AF cases has pushed clinicians to manage patients based on clinical experience, including rare situations of off-label prescriptions.


Subject(s)
Anticoagulants/administration & dosage , Atrial Fibrillation/drug therapy , Factor Xa Inhibitors/administration & dosage , Stroke/prevention & control , Administration, Oral , Aged , Aged, 80 and over , Anticoagulants/therapeutic use , Atrial Fibrillation/complications , Cardiologists/ethics , Clinical Trials, Phase III as Topic , Consensus , Dabigatran/administration & dosage , Dabigatran/adverse effects , Dabigatran/therapeutic use , Disease Management , Dose-Response Relationship, Drug , Factor Xa Inhibitors/therapeutic use , Female , Humans , Male , Middle Aged , Pyrazoles/administration & dosage , Pyrazoles/adverse effects , Pyrazoles/therapeutic use , Pyridines/administration & dosage , Pyridines/adverse effects , Pyridines/therapeutic use , Pyridones/administration & dosage , Pyridones/adverse effects , Pyridones/therapeutic use , Randomized Controlled Trials as Topic , Rivaroxaban/administration & dosage , Rivaroxaban/adverse effects , Rivaroxaban/therapeutic use , Stroke/etiology , Thiazoles/administration & dosage , Thiazoles/adverse effects , Thiazoles/therapeutic use , Vitamin K/antagonists & inhibitors , Warfarin/administration & dosage , Warfarin/adverse effects , Warfarin/therapeutic use
20.
J Electrocardiol ; 59: 93-99, 2020.
Article in English | MEDLINE | ID: mdl-32035356

ABSTRACT

INTRODUCTION: ST segment elevation (STE) in the standard 12­lead surface electrocardiography (ECG) is a well-known finding in patients with metastatic cardiac tumors. It is important to identify the specific characteristics of STE among those patients to prevent unnecessary aggressive treatments. In the present study, we aimed to demonstrate the ECG characteristics of patients with metastatic cardiac tumors who has STE. MATERIAL AND METHODS: Medical literature was searched from Pubmed database with key words "metastatic cardiac tumors" or "cardiac tumors" and "ST segment elevation" or "ST elevation". In addition, remaining articles were explored using the references of case reports which were obtained during former screening (snowball procedure). RESULTS: Thirty six of 46 case reports were included and ECG characteristics of each case were evaluated. Convex- shaped STE was observed in all patients and it showed a specific coronary territory in 35 of 36 patients (97.2%). Pathologic Q wave and/or loss of R wave progression were observed in only one patient. T wave inversion following STE was detected in 34 patients (94.4%). STE evolution was absent in 32 of 36 patients while the information regarding STE evolution were not provided in the remaining cases. CONCLUSION: STE due to tumor invasion has certain characteristics which could help clinicians in the differential diagnosis.


Subject(s)
Heart Neoplasms , Myocardial Infarction , Arrhythmias, Cardiac , Diagnosis, Differential , Electrocardiography , Heart Neoplasms/diagnosis , Humans , Myocardial Infarction/diagnosis
SELECTION OF CITATIONS
SEARCH DETAIL
...