Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
Add more filters










Publication year range
1.
World J Pediatr Congenit Heart Surg ; : 21501351241247498, 2024 May 07.
Article in English | MEDLINE | ID: mdl-38715424

ABSTRACT

We describe complex atrial baffling procedures in the setting of left isomerism with right-hand as opposed to left-handed ventricular topology. An appropriate understanding of the connections of the systemic and pulmonary veins, along with the internal atrial anatomy, as revealed using 3D printing, allowed for successful biventricular repair.

2.
Sultan Qaboos Univ Med J ; 23(Spec Iss): 55-58, 2023 Dec.
Article in English | MEDLINE | ID: mdl-38161755

ABSTRACT

Temporary epicardial cardiac pacing in patients with bradyarrhythmias may be used as a bridge to implantation of a permanent pacemaker. The temporary epicardial lead placement may sometimes necessitate a sternotomy that may pose a challenge in patients who have had multiple earlier sternotomies. The difficulty in accessing the epicardium for urgent implantation of temporary epicardial pacing leads depends on the extent of adhesions in such patients. We report an 8-year-8-month-old girl with a pacemaker with an extruded pulse generator and difficult myocardial access due to 5 prior transsternal procedures. The child presented to a tertiary care hospital in Muscat, Oman, in 2021. A trouble-shooting technique was adopted to achieve temporary epicardial pacing to provide time for a course of antibiotic therapy administration. A permanent transvenous pulse generator system was implanted after 7 days of temporary pacing.


Subject(s)
Pacemaker, Artificial , Sternotomy , Child , Female , Humans , Infant , Pacemaker, Artificial/adverse effects , Syndrome , Heart , Oman
3.
Sultan Qaboos Univ Med J ; 23(Spec Iss): 63-67, 2023 Dec.
Article in English | MEDLINE | ID: mdl-38161763

ABSTRACT

With the focus on an idiographic approach whereby the observations incorporated the various dimensions of individual functioning 'top-down' to 'bottom-up', this case report describes the successful management of a 14-year-old girl with Kearns-Sayre syndrome and Dyggve-Melchior-Clausen disease requiring a transvenous permanent pacemaker implantation for complete heart block. The patient presented to a tertiary care centre in Muscat, Oman, in 2023 seeking consultation. The current idiographic approach appears to have a heuristic value for 2 interrelated reasons. Firstly, it is unlikely that even tertiary care units can accrue such rare presentations and scrutinise them under nomothetic approach. Secondly, by employing the idiographic approach that is capable of examining each case in-depth, the aspiration for good health and well-being may come to the forefront. To the best of the authors' knowledge this is the first published idiographic report in anaesthesia care.


Subject(s)
Dwarfism , Kearns-Sayre Syndrome , Propofol , Female , Humans , Adolescent , Propofol/therapeutic use , Oman
6.
Ann Card Anaesth ; 25(2): 210-213, 2022.
Article in English | MEDLINE | ID: mdl-35417973

ABSTRACT

A diagnosis of congenital long QT interval syndrome based on history and electrocardiogram was made in a child in the absence of readily available genetic testing. A genotype 3 (LQT3) was suspected after exclusion of other variants as the child was non-responsive to beta-blocker and sodium channel blocker medication. As the child continues to show episodic bradycardia, polymorphic ventricular ectopy, and T-wave alternans, a single-chamber automated implantable cardioverter-defibrillator implantation was done successfully. This report highlights how the diagnosis of LQT3 was arrived at as well as the anesthetic challenges in the management of patients with LQTS.


Subject(s)
Defibrillators, Implantable , Long QT Syndrome , Adrenergic beta-Antagonists/therapeutic use , Arrhythmias, Cardiac , Child , Electrocardiography , Humans , Long QT Syndrome/diagnosis , Long QT Syndrome/genetics , Long QT Syndrome/therapy
7.
J Interv Card Electrophysiol ; 63(2): 399-407, 2022 Mar.
Article in English | MEDLINE | ID: mdl-34156610

ABSTRACT

PURPOSE: Cardiac resynchronization therapy (CRT) with multipoint left ventricular (LV) pacing (MultiPoint™ Pacing, MPP) has been shown to improve CRT response, although MPP response using automated pacing vector programming has not been demonstrated in the Middle East. The purpose of this study was to compare the impact of MPP to conventional biventricular pacing (BiV) using echocardiographic and clinical changes at 6-month post-implant. METHODS: This prospective, randomized study was conducted at 13 Middle Eastern centers. After de novo CRT-D implant (Abbott Unify Quadra MP™ or Quadra Assura MP™) with quadripolar LV lead (Abbott Quartet™), patients were randomized to either BiV or MPP therapy. In BiV patients, the LV pacing vector was selected per standard practice; in MPP patients, the two LV pacing vectors were selected automatically using VectSelect. CRT response was defined at 6-month post-implant by a reduction in LV end-systolic volume (ESV) ≥ 15%. RESULTS: One hundred and forty-two patients (61 years old, 68% male, NYHA class II/III/IV 19%/75%/6%, 33% ischemic, 57% hypertension, 52% diabetes, 158 ms QRS, 25.8% ejection fraction [EF]) were randomized to either BiV (N = 69) or MPP (N = 73). After 6 months, MPP vs. BiV patients experienced greater ESV reduction (25.0% vs. 15.3%, P = 0.08), greater EF improvement (11.9% vs. 8.6%, P = 0.36), significantly greater ESV response rate (68.5% vs. 50.7%, P = 0.04), and significantly greater NYHA class improvement rate (80.8% vs. 60.3%, P = 0.01). CONCLUSIONS: With MPP and automatic LV vector selection, more CRT patients in the Middle East experienced reverse remodeling and clinical improvement relative to conventional BiV pacing.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Cardiac Resynchronization Therapy/adverse effects , Cardiac Resynchronization Therapy Devices , Female , Humans , Male , Middle Aged , Stroke Volume/physiology , Treatment Outcome , Ventricular Function, Left/physiology
8.
Herzschrittmacherther Elektrophysiol ; 29(2): 236-237, 2018 Jun.
Article in English | MEDLINE | ID: mdl-29876875
11.
Heart Views ; 16(4): 125-30, 2015.
Article in English | MEDLINE | ID: mdl-26900416

ABSTRACT

BACKGROUND: The implantable cardioverter-defibrillator (ICD) is effective in the prevention of sudden cardiac death in high-risk patients. Little is known about ICD use in the Arabian Gulf. We designed a study to describe the characteristics and outcomes of patients receiving ICDs in the Arab Gulf region. METHODS: Gulf ICD is a prospective, multi-center, multinational, and observational study. All adult patients 18 years or older, receiving a de novo ICD implant and willing to sign a consent form will be eligible. Data on baseline characteristics, ICD indication, procedure and programing, in-hospital, and 1-year outcomes will be collected. Target enrollment is 1500 patients, which will provide adequate precision across a wide range of expected event rates. RESULTS: Fifteen centers in six countries are enrolling patients (Saudi Arabia, United Arab Emirates, Kuwait, Oman, Bahrain, and Qatar). Two-thirds of the centers have dedicated electrophysiology laboratories, and in almost all centers ICDs are implanted exclusively by electrophysiologists. Nearly three-quarters of the centers reported annual ICD implant volumes of ≤150 devices, and pulse generator replacements constitute <30% of implants in the majority of centers. Enrollment started in December 2013, and accrual rate increased as more centers entered the study reaching an average of 98 patients per month. CONCLUSIONS: Gulf ICD is the first prospective, observational, multi-center, and multinational study of the characteristics and, the outcomes of patients receiving ICDs in the Arab Gulf region. The study will provide valuable insights into the utilization of and outcomes related to ICD therapy in the Gulf region.

SELECTION OF CITATIONS
SEARCH DETAIL
...