Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 39
Filter
1.
Surg Endosc ; 2024 May 10.
Article in English | MEDLINE | ID: mdl-38727831

ABSTRACT

BACKGROUND: Near-infrared fluorescence (NIRF) angiography with intraoperative administration of indocyanine green (ICG) has rapidly disseminated in clinical practice. Another clinically approved, and widely available dye, methylene blue (MB), has up to now not been used for this purpose. Recently, we demonstrated promising results for the real-time evaluation of intestinal perfusion using this dye. The primary aim of this study was to perform a quantitative analysis of bowel perfusion assessment for both ICG and MB. METHODS: Four mature female Landrace pigs underwent laparotomy under general anesthesia. An ischemic bowel loop with five regions of interest (ROIs) with varying levels of perfusion was created in each animal. An intravenous (IV) injection of 0.25 mg/kg-0.50 mg/kg MB was administered after 10 min, followed by NIRF imaging in MB mode and measurement of local lactate levels in all corresponding ROIs. This procedure was repeated in ICG mode (IV dose of 0.2 mg/kg) after 60 min. The quest spectrum fluorescence camera (Quest Medical Imaging, Middenmeer, The Netherlands) was used for NIRF imaging of both MB and ICG. RESULTS: Intraoperative NIRF imaging of bowel perfusion assessment with MB and ICG was successful in all studied animals. Ingress (i/s) levels were calculated and correlated with local lactate levels. Both MB and ICG ingress values showed a significant negative correlation (r = - 0.7709; p = < 0.001; r = - 0.5367, p = 0.015, respectively) with local lactate levels. This correlation was stronger for MB compared to ICG, although ICG analysis showed higher absolute ingress values. CONCLUSION: Our fluorescence quantification analysis validates the potential to use MB for bowel perfusion assessment besides the well-known and widely used ICG. Further human studies are necessary to translate our findings to clinical applications.

2.
Diagnostics (Basel) ; 13(8)2023 Apr 18.
Article in English | MEDLINE | ID: mdl-37189570

ABSTRACT

Near-infrared fluorescence (NIRF) image-guided surgery is a useful tool that can help reduce perioperative complications and improve tissue recognition. Indocyanine green (ICG) dye is the most frequently used in clinical studies. ICG NIRF imaging has been used for lymph node identification. However, there are still many challenges in lymph node identification by ICG. There is increasing evidence that methylene blue (MB), another clinically applicable fluorescent dye, can also be useful in the intraoperative fluorescence-guided identification of structures and tissues. We hypothesized that MB NIRF imaging could be used for lymph node identification. The aim of this study was to evaluate the feasibility of intraoperative lymph node fluorescence detection using intravenously (IV) administered MB and compare it to ICG via a camera that has two dedicated near-infrared (NIR) channels. Three pigs were used in this study. ICG (0.2 mg/kg) was administered via a peripheral venous catheter followed by immediate administration of MB (0.25 mg/kg). NIRF images were acquired as video recordings at different time points (every 10 min) over an hour using the QUEST SPECTRUM® 3 system (Quest Medical Imaging, Middenmeer, The Netherlands), which has two dedicated NIR channels for simultaneous intraoperative fluorescence guidance. The 800 nm channel was used to capture ICG fluorescence and the 700 nm channel was used for MB. The target (lymph nodes and small bowel) and the background (vessels-free field of the mesentery) were highlighted as the regions of interest (ROIs), and corresponding fluorescence intensities (FI) from these ROIs were measured. The target-to-background ratio (TBR) was then computed as the mean FI of the target minus the mean FI of the background divided by the mean FI of the background. In all included animals, a clear identification of lymph nodes was achieved at all time points. The mean TBR of ICG in lymph nodes and small bowel was 4.57 ± 1.00 and 4.37 ± 1.70, respectively for the overall experimental time. Regarding MB, the mean TBR in lymph nodes and small bowel was 4.60 ± 0.92 and 3.27 ± 0.62, respectively. The Mann-Whitney U test of the lymph node TBR/small bowel TBR showed that the TBR ratio of MB was statistically significantly higher than ICG. The fluorescence optical imaging technology used allows for double-wavelength assessment. This feasibility study proves that lymph nodes can be discriminated using two different fluorophores (MB and ICG) with different wavelengths. The results suggest that MB has a promising potential to be used to detect lymphatic tissue during image-guided surgery. Further preclinical trials are needed before clinical translation.

3.
Surg Endosc ; 37(9): 6779-6790, 2023 09.
Article in English | MEDLINE | ID: mdl-37253870

ABSTRACT

BACKGROUND: Intraoperative near-infrared fluorescence imaging (NIRF) with preoperative optical dye administration is a promising technique for quick and easy intraoperative visualization of the ureter and for an improved, real-time assessment of intestinal perfusion. During colorectal surgery, there is a need for simultaneous non-invasive ureteral imaging and bowel perfusion assessment, using one single camera system. The purpose of this study is to investigate the feasibility of simultaneous intestinal perfusion and ureteral imaging using a single commercially available NIRF imaging system. METHODS: Six Landrace pigs underwent laparotomy under general anesthesia in this experiment. An intravenous (IV) dose of 0.2 mg/kg indocyanine green (ICG) was given to assess bowel perfusion. Two pairs received a methylene blue (MB) iv injection of 0.75, 0.50 or 0.25 mg/kg respectively to investigate ureteral visualization. Quest Spectrum Fluorescence Camera (Quest Medical Imaging, Middenmeer, The Netherlands) was used for NIRF imaging. RESULTS: Ureter visualization and bowel perfusion under NIRF imaging was achieved in all animals. All ureters were visible after five to ten minutes and remained clearly visible until the end of every experiment (120-420 min). A mixed model analysis did not show any significant differences neither between the three groups nor over time. Importantly, we demonstrated that bowel perfusion could be visualized with methylene blue (MB) as well. We observed no interference between ICG and MB and a faster washout of MB. CONCLUSION: We successfully demonstrated simultaneous fluorescence angiography with ICG and ureteral imaging with MB in the same surgical procedure, with the same commercially available NIRF imaging equipment. More importantly, we showed that the use MB is adequate for bowel perfusion assessment and ureter visualization with this NIRF imaging system. Besides, MB showed an earlier washout time, which can be clinical beneficial as a repeated dye injection may be necessary during a surgical procedure.


Subject(s)
Laparoscopy , Ureter , Swine , Animals , Laparoscopy/methods , Ureter/diagnostic imaging , Ureter/surgery , Methylene Blue , Indocyanine Green , Perfusion , Optical Imaging/methods , Fluorescence
4.
Surg Endosc ; 37(3): 1901-1915, 2023 03.
Article in English | MEDLINE | ID: mdl-36258001

ABSTRACT

BACKGROUND: Several pivotal studies and international guidelines on the perioperative management of rectal cancer have been published. However, little is known about the current state of perioperative management of rectal cancer patients in clinical practice worldwide. METHODS: An online survey including 13 questions focusing on key topics related to the perioperative management of patients with rectal cancer was conducted among colorectal surgeons registered within the database of the Research Institute Against Digestive Cancer (IRCAD). RESULTS: A total of 535 respondents from 89 countries participated in the survey. Most surgeons worked in the European region (40.9%). Two hundred and fifty-four respondents (47.5%) performed less than 25% of surgical procedures laparoscopically. The most commonly used definition of the upper limit of the rectum was a fixed distance from the anal verge (23.4%). Magnetic resonance imaging was used to define the upper limit of the rectum by 258 respondents (48.2%). During total mesorectal excision (TME), 301 respondents (56.3%) used a high-tie technique. The most commonly constructed anastomosis was an end-to-end anastomosis (68.2%) with the majority of surgeons performing a leak test intraoperatively (88.9%). A total of 355 respondents (66.4%) constructed a diverting ostomy, and the majority of these surgeons constructed an enterostomy (82%). A total of 208 respondents (39.3%) closed a stoma within 8 weeks. Lastly, 135 respondents (25.2%) introduced a solid diet on postoperative day 1. CONCLUSION: There is considerable heterogeneity in the perioperative management of rectal cancer patients worldwide with several discrepancies between current international practice and recommendations from international guidelines. To achieve worldwide standardization in rectal cancer care, further research is needed to elucidate the cause of this heterogeneity and find ways of improved implementation of best practice recommendations.


Subject(s)
Rectal Neoplasms , Surgeons , Humans , Rectal Neoplasms/surgery , Rectum/surgery , Anal Canal/surgery , Surveys and Questionnaires
5.
J Magn Reson Imaging ; 57(3): 918-927, 2023 03.
Article in English | MEDLINE | ID: mdl-35852296

ABSTRACT

BACKGROUND: MRI is the reference for the diagnosis of arterial cerebral ischemia, but its role in acute mesenteric ischemia (AMI) is poorly known. PURPOSE: To assess MRI detection of early ischemic bowel lesions in a porcine model of arterial AMI. STUDY TYPE: Prospective/cohort. ANIMAL MODEL: Porcine model of arterial AMI obtained by embolization of the superior mesenteric artery (seven pigs). FIELD STRENGTH/SEQUENCE: A 5-T. T1 gradient-echo-weighted-imaging (WI), half-Fourier-acquisition-single-shot-turbo-spin-echo, T2 turbo-spin-echo, true-fast-imaging-with-steady-precession (True-FISP), diffusion-weighted-echo-planar (DWI). ASSESSMENT: T1-WI, T2-WI, and DWI were performed before and continuously after embolization for 6 hours. The signal intensity (SI) of the ischemic bowel was assessed visually and quantitatively on all sequences. The apparent diffusion coefficient (ADC) was assessed. STATISTICAL TESTS: Paired Student's t-test or Mann-Whitney U-test, significance at P < 0.05. RESULTS: One pig died from non-AMI-related causes. The remaining pigs underwent a median 5 h53 (range 1 h24-6 h01) of ischemia. Visually, the ischemic bowel showed signal hyperintensity on DWI-b800 after a median 85 (57-276) minutes compared to the nonischemic bowel. DWI-b800 SI significantly increased after 2 hours (+19%) and the ADC significant decrease within the first hour (-31%). The ischemic bowel was hyperintense on precontrast T1-WI after a median 87 (70-171) minutes with no significant quantitative changes over time (P = 0.46-0.93). The ischemic bowel was hyperintense on T2-WI in three pigs with a significant SI increase on True-FISP after 1 and 2 hours. DATA CONCLUSION: Changes in SI and ADC can be seen early after the onset of arterial AMI with DWI. The value of T2-WI appears to be limited. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 2.


Subject(s)
Mesenteric Ischemia , Animals , Swine , Mesenteric Ischemia/diagnostic imaging , Prospective Studies , Magnetic Resonance Imaging/methods , Ischemia/diagnostic imaging , Ischemia/pathology , Diffusion Magnetic Resonance Imaging/methods
6.
Surg Endosc ; 37(2): 950-957, 2023 02.
Article in English | MEDLINE | ID: mdl-36068388

ABSTRACT

BACKGROUND: Ischemia at the site of an intestinal anastomosis is one of the most important risk factors for anastomotic leakage (AL). Consequently, adequate intestinal microperfusion is essential for optimal tissue oxygenation and anastomotic healing. As visual inspection of tissue viability does not guarantee an adequate objective evaluation of intestinal microperfusion, surgeons are in dire need of supportive tools to decrease anastomotic leakage after colorectal surgery. METHODS: In this feasibility study, laparoscopic laser speckle contrast imaging (LSCI) was used to evaluate intestinal microperfusion in an experimental ischemic bowel loop model. Both large and small ischemic loops were created from the small intestine of a pig; each loop was divided into 5 regions of interest (ROI) with varying levels of ischemia. Speckle contrast and local capillary lactate (LCL) was measured in all ROIs. RESULTS: Both real-time visualization of intestinal microperfusion and induced perfusion deficits was achieved in all bowel loops. As a result, the emergence of regions of intestinal ischemia could be predicted directly after iatrogenic perfusion limitation, whereas without LSCI signs of decreased intestinal viability could only be seen after 30 minutes. Additionally, a significant relation was found between LCL and LSCI. CONCLUSION: In conclusion, LSCI can achieve real-time intraoperative visualization of intestinal microperfusion deficits, allowing for accurate prediction of long-term postoperative ischemic complications. With this revealing capacity, LSCI could potentially facilitate surgical decision-making when constructing intestinal anastomoses in order to mitigate ischemia-related complications such as AL.


Subject(s)
Anastomotic Leak , Laparoscopy , Swine , Animals , Anastomotic Leak/etiology , Laser Speckle Contrast Imaging , Anastomosis, Surgical/methods , Laparoscopy/methods , Postoperative Complications/etiology , Perfusion , Ischemia/etiology , Perfusion Imaging/methods
7.
Diagnostics (Basel) ; 14(1)2023 Dec 22.
Article in English | MEDLINE | ID: mdl-38201335

ABSTRACT

Accurate preoperative localization is crucial for successful minimally invasive parathyroidectomy in primary hyperparathyroidism (PHPT). Preoperative localization can be challenging in patients with recurrent and/or multigland disease (MGD). This has led clinicians to investigate multiple imaging techniques, most of which are associated with radiation exposure. Magnetic resonance imaging (MRI) offers ionizing radiation-free and accurate imaging, making it an attractive alternative imaging modality. The objective of this systematic review is to provide an overview of the diagnostic performance of MRI in the localization of PHPT. PubMed and Embase libraries were searched from 1 January 2000 to 31 March 2023. Studies were included that investigated MRI techniques for the localization of PHPT. The exclusion criteria were (1) secondary/tertiary hyperparathyroidism, (2) studies that provided no diagnostic performance values, (3) studies published before 2000, and (4) studies using 0.5 Tesla MRI scanners. Twenty-four articles were included in the systematic review, with a total of 1127 patients with PHPT. In 14 studies investigating conventional MRI for PHPT localization, sensitivities varied between 39.1% and 94.3%. When employing more advanced MRI protocols like 4D MRI for PHPT localization in 11 studies, sensitivities ranged from 55.6% to 100%. The combination of MR imaging with functional techniques such as 18F-FCH-PET/MRI yielded the highest diagnostic accuracy, with sensitivities ranging from 84.2% to 100% in five studies. Despite the limitations of the available evidence, the results of this review indicate that the combination of MR imaging with functional imaging techniques such as 18F-FCH-PET/MRI yielded the highest diagnostic accuracy. Further research on emerging MR imaging modalities, such as 4D MRI and PET/MRI, is warranted, as MRI exposes patients to minimal or no ionizing radiation compared to other imaging modalities.

8.
Diagnostics (Basel) ; 12(9)2022 Sep 15.
Article in English | MEDLINE | ID: mdl-36140626

ABSTRACT

Complete mesocolic excision (CME), which involves the adequate resection of the tumor-bearing colonic segment with "en bloc" removal of its mesocolon along embryological fascial planes is associated with superior oncological outcomes. However, CME presents a higher complication rate compared to non-CME resections due to a higher risk of vascular injury. Hyperspectral imaging (HSI) is a contrast-free optical imaging technology, which facilitates the quantitative imaging of physiological tissue parameters and the visualization of anatomical structures. This study evaluates the accuracy of HSI combined with deep learning (DL) to differentiate the colon and its mesenteric tissue from retroperitoneal tissue. In an animal study including 20 pig models, intraoperative hyperspectral images of the sigmoid colon, sigmoid mesentery, and retroperitoneum were recorded. A convolutional neural network (CNN) was trained to distinguish the two tissue classes using HSI data, validated with a leave-one-out cross-validation process. The overall recognition sensitivity of the tissues to be preserved (retroperitoneum) and the tissues to be resected (colon and mesentery) was 79.0 ± 21.0% and 86.0 ± 16.0%, respectively. Automatic classification based on HSI and CNNs is a promising tool to automatically, non-invasively, and objectively differentiate the colon and its mesentery from retroperitoneal tissue.

9.
Life (Basel) ; 12(8)2022 Aug 16.
Article in English | MEDLINE | ID: mdl-36013430

ABSTRACT

BACKGROUND: Intestinal resection causes inevitable vascular damage, which cannot always be seen during an intraoperative clinical assessment of local intestinal perfusion. If left unaltered, impaired perfusion can lead to complications, such as anastomotic leakage (AL). Therefore, we demonstrate the use of a novel laparoscopic laser speckle contrast imaging (LSCI)-based approach in order to assess local intestinal perfusion during the construction of intestinal anastomoses. METHODS: Three segments were isolated from the small intestine of a pig, while the perfusion of each was compromised by coagulating 7-8 mesenteric arteries. Both clinical assessments and LSCI were used to detect the induced perfusion deficits and to subsequently guide a transection in either a well perfused, marginally perfused, or poorly perfused tissue area within the segment. Bowel ends were then utilized for the creation of three differently perfused anastomoses: well perfused/well perfused (anastomosis segment 1), well perfused/poorly perfused (anastomosis segment 2), and poorly perfused/poorly perfused (anastomosis segment 3). After construction of the anastomoses, a final perfusion assessment using both clinical assessment and LSCI was executed in order to evaluate the vascular viability of the anastomosis. RESULTS: Laparoscopic LSCI enabled continuous assessment of local intestinal perfusion and allowed for detection of perfusion deficits in real time. The imaging feedback precisely guided the surgical procedure, and, when evaluating the final anastomotic perfusion, LSCI was able to visualize the varying degrees of perfusion, whereas standard clinical assessment yielded only minor differences in visual appearance of the tissue. CONCLUSIONS: In this technical note, we demonstrate a novel LSCI-based approach for intraoperative perfusion assessment. With its ability to continuously visualize perfusion in real time, laparoscopic LSCI has significant potential for the optimization of anastomotic surgery in the near future.

10.
Life (Basel) ; 12(8)2022 Jul 27.
Article in English | MEDLINE | ID: mdl-35892925

ABSTRACT

Over the last decade fluorescence-guided surgery has been primarily focused on the NIR-I window. However, the NIR-I window has constraints, such as limited penetration and scattering. Consequently, exploring the performance of NIR-I dyes at longer wavelengths (i.e., the NIR-II window) is crucial to expanding its application. Two fluorophores were used in three pigs to identify the mean fluorescence intensity (MFI) using two commercially available NIR-I and NIR-II cameras. The near-infrared coating of equipment (NICE) was used to identify endoluminal surgical catheters and indocyanine green (ICG) for common bile duct (CBD) characterization. The NIR-II window evaluation showed an MFI of 0.4 arbitrary units (a.u.) ± 0.106 a.u. in small bowel NICE-coated catheters and an MFI of 0.09 a.u. ± 0.039 a.u. in gastric ones. In CBD characterization, the ICG MFI was 0.12 a.u. ± 0.027 a.u., 0.18 a.u. ± 0.100 a.u., and 0.22 a.u. ± 0.041 a.u. at 5, 35, and 65 min, respectively. This in vivo imaging evaluation of NIR-I dyes confirms its application in the NIR-II domain. To the best of our knowledge, this is the first study assessing the MIF of NICE in the NIR-II window using a commercially available system. Further comparative trials are necessary to determine the superiority of NIR-II imaging systems.

11.
Diagnostics (Basel) ; 12(1)2022 Jan 13.
Article in English | MEDLINE | ID: mdl-35054352

ABSTRACT

Mastectomy skin flap necrosis (MSFN) and partial DIEP (deep inferior epigastric artery perforator) flap loss represent two frequently reported complications in immediate autologous breast reconstruction. These complications could be prevented when areas of insufficient tissue perfusion are detected intraoperatively. Hyperspectral imaging (HSI) is a relatively novel, non-invasive imaging technique, which could be used to objectively assess tissue perfusion through analysis of tissue oxygenation patterns (StO2%), near-infrared (NIR%), tissue hemoglobin (THI%), and tissue water (TWI%) perfusion indices. This prospective clinical pilot study aimed to evaluate the efficacy of HSI for tissue perfusion assessment and to identify a cut-off value for flap necrosis. Ten patients with a mean age of 55.4 years underwent immediate unilateral autologous breast reconstruction. Prior, during and up to 72 h after surgery, a total of 19 hyperspectral images per patient were acquired. MSFN was observed in 3 out of 10 patients. No DIEP flap necrosis was observed. In all MSFN cases, an increased THI% and decreased StO2%, NIR%, and TWI% were observed when compared to the vital group. StO2% was found to be the most sensitive parameter to detect MSFN with a statistically significant lower mean StO2% (51% in the vital group versus 32% in the necrosis group, p < 0.0001) and a cut-off value of 36.29% for flap necrosis. HSI has the potential to accurately assess mastectomy skin flap perfusion and discriminate between vital and necrotic skin flap during the early postoperative period prior to clinical observation. Although the results should be confirmed in future studies, including DIEP flap necrosis specifically, these findings suggest that HSI can aid clinicians in postoperative mastectomy skin flap and DIEP flap monitoring.

12.
Surg Endosc ; 36(8): 5840-5853, 2022 08.
Article in English | MEDLINE | ID: mdl-35064320

ABSTRACT

INTRODUCTION: To assess the current approaches and perioperative treatments of laparoscopic right hemicolectomy (LRHC) and to highlight similarities and differences with international guidelines and scientific evidence, we conducted a survey for surgeons across the globe. METHODS: All digestive and colorectal surgeons registered with the database of the Research Institute against Digestive Cancer (IRCAD) were invited to take part in the survey via email and through the social media networks of IRCAD. RESULTS: There were a total of 440 respondents from 78 countries. Most surgeons worked in the European region (38.6%) followed by the Americas (34.1%), the Eastern Mediterranean region (13.0%), the South-East Asian region (5.9%), the Western Pacific region (4.8%), and Africa (3.2%) respectively. Over half of the respondents performed less than 25% of right hemicolectomies laparoscopically where 4 ports are usually used by 68% of the surgeons. The medial-to-lateral, vessel-first approach is the approach most commonly used (74.1%). The most common extraction site was through a midline incision (53%) and an abdominal drain tube is routinely used by 52% of the surgeons after surgery. A total of 68.6% of the responding surgeons perform the majority of the anastomoses extracorporeally. Finally, we found that the majority of responders (60.7%) routinely used mechanical bowel preparations prior to LRHC. CONCLUSION: Regarding several topics related to LRHC care, a discrepancy was observed between the current medical practice and the recommendations from RCTs and international guidelines and significant regional differences were observed.


Subject(s)
Laparoscopy , Surgeons , Colectomy , Humans , Surveys and Questionnaires
13.
Minim Invasive Ther Allied Technol ; 31(3): 342-349, 2022 Mar.
Article in English | MEDLINE | ID: mdl-33000653

ABSTRACT

BACKGROUND: Urethral injury is a dreaded complication during laparoscopic, perineal and transanal surgery and is mainly a result of a failed visualization of the urethra. The aim of this systematic review is to provide an overview of the available literature on the near-infrared fluorescence (NIRF) imaging technique using contrast agents for the intra-operative visualization of the urethra. MATERIAL AND METHODS: A systematic review of the literature was conducted including studies on NIRF imaging using contrast agents to visualize the urethra. All studies describing a NIRF imaging technique and demonstrating visual findings of the urethra were included. RESULTS: Five studies were identified. Four studies examined indocyanine green, one of which also studied the IRDye® 800BK agent and one examined the CP-IRT dye. All studies showed that the NIRF imaging technique was feasible for an early identification of the urethra. No complications related to NIRF imaging were reported. CONCLUSION: We conclude that the use of a NIRF imaging technique is feasible and that it can contribute to prevent iatrogenic injury to the urethra. However, based on the limited available data, no solid conclusion can yet be drawn and further translation to the clinical practice is necessary.


Subject(s)
Laparoscopy , Urethra , Fluorescent Dyes , Humans , Indocyanine Green , Laparoscopy/methods , Male , Optical Imaging/methods , Urethra/diagnostic imaging , Urethra/surgery
14.
Surg Endosc ; 36(1): 826-832, 2022 01.
Article in English | MEDLINE | ID: mdl-34741202

ABSTRACT

BACKGROUND: Laparoscopic endoscopic cooperative colorectal surgery (LECS-CR) is a promising technique to achieve full-thickness resection of colorectal tumors. This approach has shown good rates of complete resection and low local recurrence, especially for large laterally spreading tumors, which are difficult to remove via endoscopy alone. However, it is often difficult to prevent peritoneal leakage of intestinal content, causing infections and risks of cancer spreading. It was hypothesized that a robotic assistance could make the procedure easier and decrease intestinal fluid leakage. This preclinical trial aims to assess the feasibility of robotic and endoscopic cooperative colorectal surgery (RECS-CR). METHODS: LECS-CR was performed in five female pigs and RECS-CR was also performed in five female pigs. With the animal under general anesthesia, pseudotumors were created on the colonic mucosa at a distance comprised between 20 and 25 cm from the anal verge. Desired resection margins were marked endoscopically and two stay sutures were placed either robotically or laparoscopically. A mucosa-to-submucosa dissection was performed endoscopically along the markings. Complete full-thickness dissection was performed cooperatively. The specimen was withdrawn endoscopically. The colon was closed using a self-fixating running suture. Abdominal contaminations, operating times, complications, and complete resections were evaluated and compared between LECS-CR and RECS-CR. RESULTS: The mean number of colonies of Escherichia coli in the RECS group was significantly lower than in the LECS group (36.7 ± 30.2 vs. 142.2 ± 78.4, respectively, p < 0.05). Operating time was comparable (118 ± 11.2 vs. 98.6 ± 25.7, respectively, p = 0.22). Two stenoses occurred in the LECS group. R0 resection was achieved in all cases. CONCLUSION: This study suggests that RECS-CR is feasible and has the potential to reduce intestinal content leakage, potentially preventing postoperative infections.


Subject(s)
Colorectal Neoplasms , Laparoscopy , Robotic Surgical Procedures , Animals , Colorectal Neoplasms/surgery , Feasibility Studies , Female , Laparoscopy/methods , Swine , Treatment Outcome
15.
Diagnostics (Basel) ; 11(9)2021 Aug 24.
Article in English | MEDLINE | ID: mdl-34573869

ABSTRACT

Hyperspectral imaging (HSI) is a non-invasive imaging modality already applied to evaluate hepatic oxygenation and to discriminate different models of hepatic ischemia. Nevertheless, the ability of HSI to detect and predict the reperfusion damage intraoperatively was not yet assessed. Hypoxia caused by hepatic artery occlusion (HAO) in the liver brings about dreadful vascular complications known as ischemia-reperfusion injury (IRI). Here, we show the evaluation of liver viability in an HAO model with an artificial intelligence-based analysis of HSI. We have combined the potential of HSI to extract quantitative optical tissue properties with a deep learning-based model using convolutional neural networks. The artificial intelligence (AI) score of liver viability showed a significant correlation with capillary lactate from the liver surface (r = -0.78, p = 0.0320) and Suzuki's score (r = -0.96, p = 0.0012). CD31 immunostaining confirmed the microvascular damage accordingly with the AI score. Our results ultimately show the potential of an HSI-AI-based analysis to predict liver viability, thereby prompting for intraoperative tool development to explore its application in a clinical setting.

16.
Sci Rep ; 11(1): 9650, 2021 05 06.
Article in English | MEDLINE | ID: mdl-33958693

ABSTRACT

Intraoperative indocyanine green (ICG) fluorescence angiography has gained popularity and acceptance in many surgical fields for the real-time assessment of tissue perfusion. Although vasopressors have the potential to preclude an accurate assessment of tissue perfusion, there is a lack of literature with regards to its effect on ICG fluorescence angiography. An experimental porcine model was used to expose the small bowel for quantitative tissue perfusion assessment. Three increasing doses of norepinephrine infusion (0.1, 0.5, and 1.0 µg/kg/min) were administered intravenously over a 25-min interval. Time-to-peak fluorescence intensity (TTP) was the primary outcome. Secondary outcomes included absolute fluorescence intensity and local capillary lactate (LCL) levels. Five large pigs (mean weight: 40.3 ± 4.24 kg) were included. There was no significant difference in mean TTP (in seconds) at baseline (4.23) as compared to the second (3.90), third (4.41), fourth (4.60), and fifth ICG assessment (5.99). As a result of ICG accumulation, the mean and the maximum absolute fluorescence intensity were significantly different as compared to the baseline assessment. There was no significant difference in LCL levels (in mmol/L) at baseline (0.74) as compared to the second (0.82), third (0.64), fourth (0.60), and fifth assessment (0.62). Increasing doses of norepinephrine infusion have no significant influence on bowel perfusion using ICG fluorescence angiography.


Subject(s)
Fluorescein Angiography/methods , Indocyanine Green , Norepinephrine/pharmacology , Vasoconstrictor Agents/pharmacology , Animals , Disease Models, Animal , Female , Infusions, Intravenous , Injections, Intravenous , Intestines/blood supply , Intraoperative Period , Laparotomy , Norepinephrine/administration & dosage , Swine , Vasoconstrictor Agents/administration & dosage
17.
Surg Innov ; 28(6): 669-678, 2021 Dec.
Article in English | MEDLINE | ID: mdl-33787401

ABSTRACT

BACKGROUND: Despite the increasing number of laparoscopic hepatic procedures for the resection of hepatocellular carcinoma (HCC), intraoperative tumor localization and demarcation remains challenging in comparison to open surgery. In this study, we evaluated the feasibility of positive liver segment staining through the super-selective intra-arterial indocyanine green (ICG) administration. METHODS: Eight patients presenting with a single HCC underwent an interventional vascular procedure followed by laparoscopic surgery. A microcatheter was advanced into the hepatic artery branches perfusing the HCC followed by digital subtraction angiography and angiography computed tomography (angio-CT). Patients were then transferred to the operating room, and a laparoscopic hepatectomy was performed under ultrasound guidance. A 5 mL bolus of ICG with a concentration of .125 mg/mL was injected through the microcatheter, and a near-infrared laparoscope was used to detect the fluorescence signal to assess the correspondence between the fluorescence-based demarcation and the intraoperative ultrasound-based demarcation. RESULTS: The duration for the angiography procedure was 32.7 +/- 5.3 min, and it took 242 +/- 118 min from the end of angiography procedure until the start of the surgical procedure. In all cases, the fluorescent liver segment was corresponding to the angio-CT findings. In 6/8 cases, fluorescence imaging was considered helpful in the identification of the resection line. In 3 patients, the resection line was changed according to the positively stained liver segment. CONCLUSION: We successfully demonstrated the feasibility of the super-selective intra-arterial ICG administration for fluorescence-based positive staining of hepatic segmentation during laparoscopic surgery for HCC (NCT04266548).


Subject(s)
Carcinoma, Hepatocellular , Laparoscopy , Liver Neoplasms , Carcinoma, Hepatocellular/diagnostic imaging , Carcinoma, Hepatocellular/surgery , Feasibility Studies , Humans , Indocyanine Green , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/surgery , Staining and Labeling
18.
Int J Med Sci ; 18(7): 1541-1553, 2021.
Article in English | MEDLINE | ID: mdl-33746570

ABSTRACT

Dual emissions at ~700 and 800 nm have been achieved from a single NIR-AZA fluorophore 1 by establishing parameters in which it can exist in either its isolated molecular or aggregated states. Dual near infrared (NIR) fluorescence color lymph node (LN) mapping with 1 was achieved in a large-animal porcine model, with injection site, channels and nodes all detectable at both 700 and 800 nm using a preclinical open camera system. The fluorophore was also compatible with imaging using two clinical instruments for fluorescence guided surgery. Methods: An NIR-AZA fluorophore with hydrophilic and phobic features was synthesised in a straightforward manner and its aggregation properties characterised spectroscopically and by TEM imaging. Toxicity was assessed in a rodent model and dual color fluorescence imaging evaluated by lymph node mapping in a large animal porcine models and in ex-vivo human tissue specimen. Results: Dual color fluorescence imaging has been achieved in the highly complex biomedical scenario of lymph node mapping. Emissions at 700 and 800 nm can be achieved from a single fluorophore by establishing molecular and aggregate forms. Fluorophore was compatible with clinical systems for fluorescence guided surgery and no toxicity was observed in high dosage testing. Conclusion: A new, biomedical compatible form of NIR-dual emission wavelength imaging has been established using a readily accessible fluorophore with significant scope for clinical translation.


Subject(s)
Endoscopy/methods , Fluorescent Dyes/administration & dosage , Lymph Nodes/diagnostic imaging , Optical Imaging/methods , Animals , Endoscopy/instrumentation , Female , Fluorescent Dyes/chemistry , Fluorescent Dyes/toxicity , HeLa Cells , Humans , Intraoperative Care/instrumentation , Intraoperative Care/methods , Intravital Microscopy/methods , Lymphatic Metastasis/diagnosis , Male , Models, Animal , Neoplasms/pathology , Neoplasms/surgery , Optical Imaging/instrumentation , Porphobilinogen/administration & dosage , Porphobilinogen/analogs & derivatives , Porphobilinogen/chemistry , Porphobilinogen/toxicity , Rats , Spectrophotometry, Infrared/instrumentation , Spectrophotometry, Infrared/methods , Sus scrofa , Toxicity Tests, Subacute/methods
19.
Sci Rep ; 11(1): 4501, 2021 02 24.
Article in English | MEDLINE | ID: mdl-33627768

ABSTRACT

Iatrogenic ureteral injuries (IUI) occur in 0.5-1.3% of cases during abdominal surgery. If not recognized intraoperatively, IUI increase morbidity/mortality. A universally accepted method to prevent IUI is lacking. Near-infrared fluorescent imaging (NIRF), penetrating deeper than normal light within the tissue, might be useful, therefore ureter visualization combining NIRF with special dyes (i.e. IRDye 800BK) is promising. Aim of this work is to evaluate the detection of ureters using stents coated with a novel biocompatible fluorescent material (NICE: near-infrared coating of equipment), during laparoscopy. female pigs underwent placement of NICE-coated stents (NS). NIRF was performed, and fluorescence intensity (FI) was computed. Successively, 0.15 mg/kg of IRDye 800BK was administered intravenously, and FI was computed at different timepoints. Ureter visualization using NS only was further assessed in a human cadaver. Both methods allowed in vivo ureter visualization, with equal FI. However, NS were constantly visible whereas IRDye 800BK allowed visualization exclusively during the ureteral peristaltic phases. In the human cadaver, NS provided excellent ureter visualization in its natural anatomical position. NS provided continuous ureteral visualization with similar FI as the IRDye 800BK, which exclusively allowed intermittent visualization, dependent on ureteral peristalsis. NS might prove useful to visualize ureters intraoperatively, potentially preventing IUI.


Subject(s)
Fluorescent Dyes/metabolism , Ureter/metabolism , Ureter/surgery , Cadaver , Catheters , Fluorescence , Humans , Laparoscopy/methods , Optical Imaging/methods
20.
Surg Endosc ; 35(12): 7142-7153, 2021 12.
Article in English | MEDLINE | ID: mdl-33492508

ABSTRACT

BACKGROUND: Anastomotic leakage (AL) is one of the dreaded complications following surgery in the digestive tract. Near-infrared fluorescence (NIRF) imaging is a means to intraoperatively visualize anastomotic perfusion, facilitating fluorescence image-guided surgery (FIGS) with the purpose to reduce the incidence of AL. The aim of this study was to analyze the current practices and results of NIRF imaging of the anastomosis in digestive tract surgery through the EURO-FIGS registry. METHODS: Analysis of data prospectively collected by the registry members provided patient and procedural data along with the ICG dose, timing, and consequences of NIRF imaging. Among the included upper-GI, colorectal, and bariatric surgeries, subgroup analysis was performed to identify risk factors associated with complications. RESULTS: A total of 1240 patients were included in the study. The included patients, 74.8% of whom were operated on for cancer, originated from 8 European countries and 30 hospitals. A total of 54 surgeons performed the procedures. In 83.8% of cases, a pre-anastomotic ICG dose was administered, and in 60.1% of cases, a post-anastomotic ICG dose was administered. A significant difference (p < 0.001) was found in the ICG dose given in the four pathology groups registered (range: 0.013-0.89 mg/kg) and a significant (p < 0.001) negative correlation was found between the ICG dose and BMI. In 27.3% of the procedures, the choice of the anastomotic level was guided by means of NIRF imaging which means that in these cases NIRF imaging changed the level of anastomosis which was first decided based on visual findings in conventional white light imaging. In 98.7% of the procedures, the use of ICG partly or strongly provided a sense of confidence about the anastomosis. A total of 133 complications occurred, without any statistical significance in the incidence of complications in the anastomoses, whether they were ICG-guided or not. CONCLUSION: The EURO-FIGS registry provides an insight into the current clinical practice across Europe with respect to NIRF imaging of anastomotic perfusion during digestive tract surgery.


Subject(s)
Indocyanine Green , Surgery, Computer-Assisted , Anastomosis, Surgical/adverse effects , Anastomotic Leak/epidemiology , Anastomotic Leak/etiology , Humans , Perfusion , Registries
SELECTION OF CITATIONS
SEARCH DETAIL
...