JACC Clin Electrophysiol ; 6(5): 523-532, 2020 05.
Article in English | MEDLINE | ID: mdl-32439036

ABSTRACT

OBJECTIVES: The aim of this study was to describe a mapping approach for ablation of complex atrial re-entrant tachycardias (ARTs) in which high-density activation maps are transformed into low-density activation maps displaying only the active part of the tachycardia circuit. BACKGROUND: High-density activation maps during complex ARTs are challenging to interpret because they include the activation patterns of active and passive circuits. Entrainment mapping provides the identification of the active tachycardia circuit. However, current electroanatomic mapping systems are not capable of color-coding the information obtained from entrainment maneuvers. METHODS: Seventeen consecutive patients with atypical atrial flutter were included. A high-density activation map was acquired during index tachycardia. Subsequently, entrainment maneuvers were performed to generate a low-density activation map in which only the activation of the atria directly involved in the flutter circuit was displayed. RESULTS: Of all patients included, 82% were men, and their mean age was 62 ± 7 years. Structural heart disease was present in 59%, and 53% had undergone prior left atrial ablation procedures. Low-density activation maps were successfully generated from an average of 14 ± 3 entrainment points. Twenty circuits (95%) were identified in the left atrium and 1 (5%) in the right atrium. Ablation guided by low-density mapping successfully terminated all ARTs in 267 ± 353 s of radiofrequency application. CONCLUSIONS: Low-density mapping based on entrainment maneuvers provides a precise delineation of the active circuit during complex ARTs and resulted in successful arrhythmia termination. This approach can be easily incorporated into clinical practice.


Subject(s)
Atrial Flutter , Catheter Ablation , Tachycardia, Supraventricular , Atrial Flutter/surgery , Heart Atria/surgery , Humans , Male , Middle Aged , Tachycardia , Tachycardia, Supraventricular/surgery
3.
Rev. esp. cardiol. (Ed. impr.) ; 73(4): 307-312, abr. 2020. tab, graf
Article in Spanish | IBECS | ID: ibc-195611

ABSTRACT

INTRODUCCIÓN Y OBJETIVOS: El marcapasos transcatéter Micra presenta una alta efectividad y una tasa de complicaciones más baja que los marcapasos convencionales. Sin embargo, se desconoce su beneficio en la población más anciana (≥ 90 años). El objetivo de este estudio es evaluar la efectividad y la seguridad de Micra en pacientes de edad ≥ 90 años. MÉTODOS: Estudio observacional prospectivo con pacientes consecutivos mayores de 70 años a los que se implantó un marcapasos Micra, divididos en 2 grupos de edad: ≥ 90 y <90 años. RESULTADOS: El Micra se implantó en 129 pacientes, 41 tenían 90 o más años y 88, menos de 90. El implante fue exitoso en 40 pacientes (97,6%) de edad ≥ 90 años y en 87 (98,9%) menores de 90 (p = 0,58). Fueron necesarias 2 o menos reposiciones en el 97,5 y el 91,9% de los pacientes respectivamente (p = 0,32). Los tiempos de procedimiento (26,1±11,6 frente a 30,3±14,2min; p = 0,11) y de fluoroscopia (6,4±4,7 frente a 7,2±4,9min; p = 0,41) fueron similares en ambos grupos. Hubo 3 complicaciones mayores (2,3%), todas en el grupo menor de 90 años: 1 perforación cardiaca, 1 hematoma femoral y 1 seudoaneurisma femoral. Un total de 13 pacientes de edad ≥ 90 años (31,7%) y 16 de los menores de 90 (18,2%) murieron durante unos seguimientos medios de 230±233 y 394±285 días respectivamente. No hubo muertes relacionadas con el dispositivo. No se observaron infección, dislocación o migración de Micra. El rendimiento eléctrico fue óptimo en el seguimiento. CONCLUSIONES: El marcapasos sin cables Micra parece efectivo y seguro en pacientes mayores de 90 años. Podría considerarse una alternativa razonable a la estimulación transvenosa convencional en esta población


INTRODUCTION AND OBJECTIVES: The Micra transcatheter pacing system has shown high effectiveness and a lower complication rate than conventional transvenous pacemakers. However, the benefit of the device is unknown in the very old population (≥ 90 years). The aim of this study was to evaluate the safety and effectiveness of Micra in patients ≥ 90 years. METHODS: We present a prospective observational study with consecutive patients aged >70 years who underwent implantation of a Micra pacemaker system. Patients were divided into 2 groups: ≥ 90 and<90 years. RESULTS: The Micra system was implanted in 129 patients, of whom 41 were aged ≥ 90 years and 88<90 years. The device was successfully implanted in 40 (97.6%) patients ≥ 90 years and in 87 (98.9%) patients<90 years (P=.58). An adequate position was achieved with need for ≤ 2 repositions in 97.5% and 91.9% of patients, respectively (P=.32). Procedure time (26.1 ±11.6 vs 30.3 ±14.2minutes; P=.11) and fluoroscopy time (6.4 ±4.7 vs 7.2 ±4.9minutes; P=0.41) were similar in the 2 groups. There were 3 major complications (2.3%), all in the group aged<90 years: 1 cardiac perforation, 1 femoral hematoma, and 1 femoral pseudoaneurysm. Thirteen patients aged ≥ 90 years (31.7%) and 16 patients aged <90 years (18.2%) died during a mean follow-up of 230±233 days and 394±285 days, respectively. There were no device-related deaths. No infection, dislocation or migration of Micra were observed. The electrical performance was optimal at follow-up. CONCLUSIONS: The Micra leadless pacing system seems to be safe and effective in patients older than 90 years. It may be considered a reasonable alternative to conventional transvenous pacing in this population


Subject(s)
Humans , Male , Female , Aged , Aged, 80 and over , Bradycardia/therapy , Pacemaker, Artificial , Records , Sinoatrial Node/physiology , Bradycardia/physiopathology , Equipment Design , Prospective Studies , Treatment Outcome
4.
Rev Esp Cardiol (Engl Ed) ; 73(4): 307-312, 2020 Apr.
Article in English, Spanish | MEDLINE | ID: mdl-31395499

ABSTRACT

INTRODUCTION AND OBJECTIVES: The Micra transcatheter pacing system has shown high effectiveness and a lower complication rate than conventional transvenous pacemakers. However, the benefit of the device is unknown in the very old population (≥ 90 years). The aim of this study was to evaluate the safety and effectiveness of Micra in patients ≥ 90 years. METHODS: We present a prospective observational study with consecutive patients aged >70 years who underwent implantation of a Micra pacemaker system. Patients were divided into 2 groups: ≥ 90 and<90 years. RESULTS: The Micra system was implanted in 129 patients, of whom 41 were aged ≥ 90 years and 88<90 years. The device was successfully implanted in 40 (97.6%) patients ≥ 90 years and in 87 (98.9%) patients<90 years (P=.58). An adequate position was achieved with need for ≤ 2 repositions in 97.5% and 91.9% of patients, respectively (P=.32). Procedure time (26.1 ±11.6 vs 30.3 ±14.2minutes; P=.11) and fluoroscopy time (6.4 ±4.7 vs 7.2 ±4.9minutes; P=0.41) were similar in the 2 groups. There were 3 major complications (2.3%), all in the group aged<90 years: 1 cardiac perforation, 1 femoral hematoma, and 1 femoral pseudoaneurysm. Thirteen patients aged ≥ 90 years (31.7%) and 16 patients aged <90 years (18.2%) died during a mean follow-up of 230±233 days and 394±285 days, respectively. There were no device-related deaths. No infection, dislocation or migration of Micra were observed. The electrical performance was optimal at follow-up. CONCLUSIONS: The Micra leadless pacing system seems to be safe and effective in patients older than 90 years. It may be considered a reasonable alternative to conventional transvenous pacing in this population.


Subject(s)
Bradycardia/therapy , Pacemaker, Artificial , Registries , Sinoatrial Node/physiopathology , Aged , Aged, 80 and over , Bradycardia/physiopathology , Equipment Design , Female , Humans , Male , Prospective Studies , Treatment Outcome
10.
Rev. esp. cardiol. Supl. (Ed. impresa) ; 9(supl.E): 67e-74e, 2009. ilus, tab
Article in Spanish | IBECS | ID: ibc-166887

ABSTRACT

Las arritmias son, sin duda, uno de los mayores problemas para el clínico a cargo de pacientes adultos con cardiopatías congénitas. Su protagonismo en el momento actual es incuestionable, pero a medida que los pacientes con cardiopatías reparadas en edad pediátrica envejezcan, es esperable que el impacto de las complicaciones arrítmicas aumente. Además, por diferentes motivos, las cardiopatías congénitas se apartan del manejo electrofisiológico habitual. En este capítulo nos disponemos a abordar de forma resumida las particularidades que las cardiopatías congénitas suponen para el especialista en arritmias, con un breve acercamiento a la terapia de resincronización cardiaca para el manejo de la insuficiencia cardiaca (AU)


Arrhythmias are a major concern for the physician treating adult congenital cardiac patients. At present, the relevance of arrhythmias in this population is unquestionable but, as the cohort of patients with cardiac defects repaired in infancy and childhood ages, its impact is expected to increase significantly. Furthermore, due to different reasons, arrhythmia management in such patients differs from the usual approach. This article provides a brief overview of the specific features of congenital heart disease that are of concern to specialists dealing with arrhythmias and includes a short introduction to the use of resynchronization therapy for treating heart failure (AU)


Subject(s)
Humans , Catheter Ablation/methods , Heart Defects, Congenital/therapy , Pacemaker, Artificial , Cardiac Resynchronization Therapy/methods , Electric Countershock/methods , Defibrillators, Implantable , Tachycardia, Atrioventricular Nodal Reentry/therapy , Body Surface Potential Mapping