ABSTRACT

Determination of the optimum pH in a coupled enzyme assay poses significant challenges because altering the pH of the reaction mixture can affect the performance of both enzymes. Here, we demonstrate a simple and reliable method to determine the pH optimum for pyruvate kinase using the pyruvate kinase/lactate dehydrogenase coupled enzyme assay. This simple and reliable method can be broadly adapted to determine the pH optimum for various enzymes that are assayed using a coupled enzyme assay.


Subject(s)
Enzyme Assays , Hydrogen-Ion Concentration , Enzyme Assays/methods , Enzyme Assays/standards , Enzyme Stability , L-Lactate Dehydrogenase/chemistry , L-Lactate Dehydrogenase/metabolism , Pyruvate Kinase/chemistry , Pyruvate Kinase/metabolism , Reproducibility of Results , Temperature