Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 55
Filter
1.
Ann Oncol ; 34(1): 101-110, 2023 01.
Article in English | MEDLINE | ID: mdl-36522816

ABSTRACT

BACKGROUND: To evaluate potential synergistic effect of pembrolizumab with radiotherapy (RT) compared with a standard-of-care (SOC) cetuximab-RT in patients with locally advanced-squamous cell carcinoma of head and neck (LA-SCCHN). PATIENTS AND METHODS: Patients with nonoperated stage III-IV SCC of oral cavity, oropharynx, hypopharynx, and larynx and unfit for receiving high-dose cisplatin were enrolled. Patients received once-daily RT up to 69.96 Gy in 33 fractions with weekly cetuximab (cetuximab-RT arm) or 200 mg Q3W pembrolizumab during RT (pembrolizumab-RT arm). The primary endpoint was locoregional control (LRC) rate 15 months after RT. To detect a difference between arms of 60%-80% in 15-month LRC, inclusion of 66 patients per arm was required to achieve a power of at least 0.85 at two-sided significance level of 0.20. RESULTS: Between May 2016 and October 2017, 133 patients were randomized to cetuximab-RT (n = 66) and pembrolizumab-RT (n = 67). Two patients (one in each arm) were not included in the analysis (a consent withdrawal and a progression before treatment start). The median age was 65 years (interquartile range 60-70 years), 92% were smokers, 60% were oropharynx (46% of oropharynx with p16+) and 75% were stage IV. Median follow-up was 25 months in both arms. The 15-month LRC rate was 59% with cetuximab-RT and 60% with pembrolizumab-RT ]odds ratio 1.05, 95% confidence interval (CI) 0.43-2.59; P = 0.91]. There was no significant difference between arms for progression-free survival (hazard ratio 0.85, 95% CI 0.55-1.32; P = 0.47) and for overall survival (hazard ratio 0.83, 95% CI 0.49-1.40; P = 0.49). Toxicity was lower in the pembrolizumab-RT arm than in the cetuximab-RT arm: 74% versus 92% patients with at least one grade ≥3 adverse events (P = 0.006), mainly due to mucositis, radiodermatitis, and rash. CONCLUSION: Compared with the SOC cetuximab-RT, pembrolizumab concomitant with RT did not improve the tumor control and survival but appeared less toxic in unfit patients with LA-SCCHN.


Subject(s)
Chemoradiotherapy , Head and Neck Neoplasms , Squamous Cell Carcinoma of Head and Neck , Aged , Humans , Middle Aged , Cetuximab/therapeutic use , Chemoradiotherapy/adverse effects , Cisplatin/therapeutic use , Head and Neck Neoplasms/therapy , Squamous Cell Carcinoma of Head and Neck/therapy
2.
Eur Phys J C Part Fields ; 82(7): 599, 2022.
Article in English | MEDLINE | ID: mdl-35821975

ABSTRACT

The selection of low-radioactive construction materials is of the utmost importance for rare-event searches and thus critical to the XENONnT experiment. Results of an extensive radioassay program are reported, in which material samples have been screened with gamma-ray spectroscopy, mass spectrometry, and 222 Rn emanation measurements. Furthermore, the cleanliness procedures applied to remove or mitigate surface contamination of detector materials are described. Screening results, used as inputs for a XENONnT Monte Carlo simulation, predict a reduction of materials background ( ∼ 17%) with respect to its predecessor XENON1T. Through radon emanation measurements, the expected 222 Rn activity concentration in XENONnT is determined to be 4.2 ( - 0.7 + 0.5 )  µ Bq/kg, a factor three lower with respect to XENON1T. This radon concentration will be further suppressed by means of the novel radon distillation system.

3.
Cancer Radiother ; 26(3): 440-444, 2022 May.
Article in English | MEDLINE | ID: mdl-34175228

ABSTRACT

PURPOSE: Endoscopic endonasal surgery (EES) is becoming a standard for most malignant sinonasal tumours. Margin analysis after piecemeal resection is complex and optimally relies on accurate histosurgical mapping. Postoperative radiotherapy may be adapted based on margin assessment mapping to reduce the dose to some sinonasal subvolumes. We assessed the use of histosurgical mapping by radiation oncologists (RO). MATERIAL AND METHODS: A French practice survey was performed across 29 ENT expert RO (2 did not answer) regarding integration of information on EES, as well as quality of operative and pathology reportsto refine radiotherapy planning after EES. This was assessed through an electronic questionnaire. RESULTS: EES was ubiquitously performed in France. Operative and pathology reports yielded accurate description of EES samples according to 66.7% of interviewed RO. Accuracy of margin assessment was however insufficient according to more than 40.0% of RO. Additional margins/biopsies of the operative bed were available in 55.2% (16/29) of the centres. In the absence of additional margins, quality of resection after EES was considered as microscopically incomplete in 48.3% or dubious in 48.3% of RO. As performed, histosurgical mapping allowed radiotherapy dose and volumes adaptation according to 26.3% of RO only. CONCLUSIONS: Standardized histosurgical mapping with margin and additional margin analysis could be more systematic. Advantages of accurate EES reporting could be dose painting radiotherapy to further decrease morbidity in sinonasal tumours.


Subject(s)
Endoscopy , Paranasal Sinus Neoplasms , France , Humans , Paranasal Sinus Neoplasms/diagnostic imaging , Paranasal Sinus Neoplasms/radiotherapy , Paranasal Sinus Neoplasms/surgery , Surveys and Questionnaires
4.
Eur Phys J C Part Fields ; 81(4): 337, 2021.
Article in English | MEDLINE | ID: mdl-34720714

ABSTRACT

The selection of low-radioactive construction materials is of utmost importance for the success of low-energy rare event search experiments. Besides radioactive contaminants in the bulk, the emanation of radioactive radon atoms from material surfaces attains increasing relevance in the effort to further reduce the background of such experiments. In this work, we present the 222 Rn emanation measurements performed for the XENON1T dark matter experiment. Together with the bulk impurity screening campaign, the results enabled us to select the radio-purest construction materials, targeting a 222 Rn activity concentration of 10 µ Bq / kg in 3.2 t of xenon. The knowledge of the distribution of the 222 Rn sources allowed us to selectively eliminate problematic components in the course of the experiment. The predictions from the emanation measurements were compared to data of the 222 Rn activity concentration in XENON1T. The final 222 Rn activity concentration of ( 4.5 ± 0.1 ) µ Bq / kg in the target of XENON1T is the lowest ever achieved in a xenon dark matter experiment.

5.
J Intellect Disabil Res ; 65(9): 863-869, 2021 09.
Article in English | MEDLINE | ID: mdl-34338393

ABSTRACT

BACKGROUND: The recent introduction of microarrays for genetic analyses has allowed higher etiological diagnostic rates in patient with intellectual disability (ID), autism spectrum disorders (ASD), epilepsy and multiple congenital anomalies (MCA), because of its resolution. This approach still results of high complexity and some limitations have been reported. In fact, it discloses several variants of unknown significance (VOUS) or incidental findings. In all cases, a massive amount of data is generated, because of this, the analysis and the interpretation is very difficult and often without a definitive conclusion. METHOD: We analysed an Italian cohort of 343 patients with ID, MCA and ASD by array-comparative genomic hybridization. The purpose of this work was to consider the proportion of the chromosomal abnormalities in such cohort and to assess the distribution of the different type of the chromosomal abnormalities concerning their pathogenic significance, their origin and their correlation to these clinical phenotypes. RESULTS: Array-comparative genomic hybridization analysis revealed 76 positive results. Abnormalities were detected in 27.8% of patients with ID, 11.1% with ASD, 10.7% with epilepsy and 19.4% with multiple congenital anomalies. The anomalies were classified in three major groups: group 1 (27 patients) with pathogenic alterations (P group); group 2 (34 patients) with VOUS potentially pathogenic (PP group); and group 3 (13 patients) with VOUS potentially benign (PB group). As expected, comparing the diagnostic groups, we observed a greater number of deletions in the P group and that all the abnormalities of the PB group were inherited. CONCLUSIONS: Our retrospective study resulted in confirming the high detection rate of microarrays. CNV classification remains a complex procedure. The difficulty in CNV classification points out the importance of the patient selection, helping the interpretation of the molecular cytogenetic results.


Subject(s)
Genetic Counseling , Intellectual Disability , Chromosome Aberrations , Comparative Genomic Hybridization , Humans , Intellectual Disability/epidemiology , Intellectual Disability/genetics , Retrospective Studies
6.
Phys Rev Lett ; 126(9): 091301, 2021 Mar 05.
Article in English | MEDLINE | ID: mdl-33750173

ABSTRACT

We report on a search for nuclear recoil signals from solar ^{8}B neutrinos elastically scattering off xenon nuclei in XENON1T data, lowering the energy threshold from 2.6 to 1.6 keV. We develop a variety of novel techniques to limit the resulting increase in backgrounds near the threshold. No significant ^{8}B neutrinolike excess is found in an exposure of 0.6 t×y. For the first time, we use the nondetection of solar neutrinos to constrain the light yield from 1-2 keV nuclear recoils in liquid xenon, as well as nonstandard neutrino-quark interactions. Finally, we improve upon world-leading constraints on dark matter-nucleus interactions for dark matter masses between 3 and 11 GeV c^{-2} by as much as an order of magnitude.

7.
Phys Rev Lett ; 122(14): 141301, 2019 Apr 12.
Article in English | MEDLINE | ID: mdl-31050482

ABSTRACT

We report the first experimental results on spin-dependent elastic weakly interacting massive particle (WIMP) nucleon scattering from the XENON1T dark matter search experiment. The analysis uses the full ton year exposure of XENON1T to constrain the spin-dependent proton-only and neutron-only cases. No significant signal excess is observed, and a profile likelihood ratio analysis is used to set exclusion limits on the WIMP-nucleon interactions. This includes the most stringent constraint to date on the WIMP-neutron cross section, with a minimum of 6.3×10^{-42} cm^{2} at 30 GeV/c^{2} and 90% confidence level. The results are compared with those from collider searches and used to exclude new parameter space in an isoscalar theory with an axial-vector mediator.

8.
Phys Rev Lett ; 122(7): 071301, 2019 Feb 22.
Article in English | MEDLINE | ID: mdl-30848617

ABSTRACT

We present first results on the scalar coupling of weakly interacting massive particles (WIMPs) to pions from 1 t yr of exposure with the XENON1T experiment. This interaction is generated when the WIMP couples to a virtual pion exchanged between the nucleons in a nucleus. In contrast to most nonrelativistic operators, these pion-exchange currents can be coherently enhanced by the total number of nucleons and therefore may dominate in scenarios where spin-independent WIMP-nucleon interactions are suppressed. Moreover, for natural values of the couplings, they dominate over the spin-dependent channel due to their coherence in the nucleus. Using the signal model of this new WIMP-pion channel, no significant excess is found, leading to an upper limit cross section of 6.4×10^{-46} cm^{2} (90% confidence level) at 30 GeV/c^{2} WIMP mass.

9.
Phys Rev Lett ; 123(25): 251801, 2019 Dec 20.
Article in English | MEDLINE | ID: mdl-31922764

ABSTRACT

We report constraints on light dark matter (DM) models using ionization signals in the XENON1T experiment. We mitigate backgrounds with strong event selections, rather than requiring a scintillation signal, leaving an effective exposure of (22±3) tonne day. Above ∼0.4 keV_{ee}, we observe <1 event/(tonne day keV_{ee}), which is more than 1000 times lower than in similar searches with other detectors. Despite observing a higher rate at lower energies, no DM or CEvNS detection may be claimed because we cannot model all of our backgrounds. We thus exclude new regions in the parameter spaces for DM-nucleus scattering for DM masses m_{χ} within 3-6 GeV/c^{2}, DM-electron scattering for m_{χ}>30 MeV/c^{2}, and absorption of dark photons and axionlike particles for m_{χ} within 0.186-1 keV/c^{2}.

10.
Phys Rev Lett ; 123(24): 241803, 2019 Dec 13.
Article in English | MEDLINE | ID: mdl-31922867

ABSTRACT

Direct dark matter detection experiments based on a liquid xenon target are leading the search for dark matter particles with masses above ∼5 GeV/c^{2}, but have limited sensitivity to lighter masses because of the small momentum transfer in dark matter-nucleus elastic scattering. However, there is an irreducible contribution from inelastic processes accompanying the elastic scattering, which leads to the excitation and ionization of the recoiling atom (the Migdal effect) or the emission of a bremsstrahlung photon. In this Letter, we report on a probe of low-mass dark matter with masses down to about 85 MeV/c^{2} by looking for electronic recoils induced by the Migdal effect and bremsstrahlung using data from the XENON1T experiment. Besides the approach of detecting both scintillation and ionization signals, we exploit an approach that uses ionization signals only, which allows for a lower detection threshold. This analysis significantly enhances the sensitivity of XENON1T to light dark matter previously beyond its reach.

11.
Phys Rev Lett ; 121(11): 111302, 2018 Sep 14.
Article in English | MEDLINE | ID: mdl-30265108

ABSTRACT

We report on a search for weakly interacting massive particles (WIMPs) using 278.8 days of data collected with the XENON1T experiment at LNGS. XENON1T utilizes a liquid xenon time projection chamber with a fiducial mass of (1.30±0.01) ton, resulting in a 1.0 ton yr exposure. The energy region of interest, [1.4,10.6] keV_{ee} ([4.9,40.9] keV_{nr}), exhibits an ultralow electron recoil background rate of [82_{-3}^{+5}(syst)±3(stat)] events/(ton yr keV_{ee}). No significant excess over background is found, and a profile likelihood analysis parametrized in spatial and energy dimensions excludes new parameter space for the WIMP-nucleon spin-independent elastic scatter cross section for WIMP masses above 6 GeV/c^{2}, with a minimum of 4.1×10^{-47} cm^{2} at 30 GeV/c^{2} and a 90% confidence level.

12.
Ann Oncol ; 29(3): 731-736, 2018 03 01.
Article in English | MEDLINE | ID: mdl-29236943

ABSTRACT

Background: Concomitant chemotherapy (CT)-radiotherapy (RT) is a standard of care in locally advanced nasopharyngeal carcinoma (NPC) and a role for induction CT is not established. Methods: Patients with locally advanced NPC, WHO type 2 or 3, were randomized to induction TPF plus concomitant cisplatin-RT or concomitant cisplatin-RT alone. The TPF regimen consisted of three cycles of Docetaxel 75 mg/m2 day 1; cisplatin 75 mg/m2 day 1; 5FU 750 mg/m2/day days 1-5. RT consisted of 70 Gy in 7 weeks plus concomitant cisplatin 40 mg/m2 weekly. Results: A total of 83 patients were included in the study. Demographics and tumour characteristics were well balanced between both arms. Most of the patients (95%) in the TPF arm received three cycles of induction CT. The rate of grade 3-4 toxicity and the compliance (NCI-CTCAE v3) during cisplatin-RT were not different between both arms. With a median follow-up of 43.1 months, the 3-year PFS rate was 73.9% in the TPF arm versus 57.2% in the reference arm [hazard ratio (HR) = 0.44; 95% confidence interval (CI): 0.20-0.97, P = 0.042]. Similarly the 3 years overall survival rate was 86.3% in the TPF arm versus 68.9% in the reference arm (HR = 0.40; 95% CI: 0.15-1.04, P = 0.05). Conclusion: In conclusion, several important aspects can be emphasized: the compliance to induction TPF was good and TPF did not compromise the tolerance of the concomitant RT-cisplatin phase. The improved PFS and overall survival rates needs to be confirmed by further trials.


Subject(s)
Antineoplastic Combined Chemotherapy Protocols/administration & dosage , Induction Chemotherapy/methods , Nasopharyngeal Carcinoma/drug therapy , Nasopharyngeal Neoplasms/drug therapy , Adult , Aged , Antineoplastic Combined Chemotherapy Protocols/adverse effects , Chemoradiotherapy/methods , Cisplatin/administration & dosage , Cisplatin/adverse effects , Docetaxel/administration & dosage , Docetaxel/adverse effects , Female , Fluorouracil/administration & dosage , Fluorouracil/adverse effects , Humans , Induction Chemotherapy/adverse effects , Kaplan-Meier Estimate , Male , Middle Aged , Nasopharyngeal Carcinoma/mortality , Nasopharyngeal Carcinoma/radiotherapy , Nasopharyngeal Neoplasms/mortality , Nasopharyngeal Neoplasms/radiotherapy
13.
Phys Rev Lett ; 119(18): 181301, 2017 Nov 03.
Article in English | MEDLINE | ID: mdl-29219593

ABSTRACT

We report the first dark matter search results from XENON1T, a ∼2000-kg-target-mass dual-phase (liquid-gas) xenon time projection chamber in operation at the Laboratori Nazionali del Gran Sasso in Italy and the first ton-scale detector of this kind. The blinded search used 34.2 live days of data acquired between November 2016 and January 2017. Inside the (1042±12)-kg fiducial mass and in the [5,40] keV_{nr} energy range of interest for weakly interacting massive particle (WIMP) dark matter searches, the electronic recoil background was (1.93±0.25)×10^{-4} events/(kg×day×keV_{ee}), the lowest ever achieved in such a dark matter detector. A profile likelihood analysis shows that the data are consistent with the background-only hypothesis. We derive the most stringent exclusion limits on the spin-independent WIMP-nucleon interaction cross section for WIMP masses above 10 GeV/c^{2}, with a minimum of 7.7×10^{-47} cm^{2} for 35-GeV/c^{2} WIMPs at 90% C.L.

14.
Phys Rev Lett ; 118(10): 101101, 2017 Mar 10.
Article in English | MEDLINE | ID: mdl-28339273

ABSTRACT

We report on a search for electronic recoil event rate modulation signatures in the XENON100 data accumulated over a period of 4 yr, from January 2010 to January 2014. A profile likelihood method, which incorporates the stability of the XENON100 detector and the known electronic recoil background model, is used to quantify the significance of periodicity in the time distribution of events. There is a weak modulation signature at a period of 431_{-14}^{+16} day in the low energy region of (2.0-5.8) keV in the single scatter event sample, with a global significance of 1.9σ; however, no other more significant modulation is observed. The significance of an annual modulation signature drops from 2.8σ, from a previous analysis of a subset of this data, to 1.8σ with all data combined. Single scatter events in the low energy region are thus used to exclude the DAMA/LIBRA annual modulation as being due to dark matter electron interactions via axial vector coupling at 5.7σ.

15.
Cancer Radiother ; 20(5): 357-61, 2016 Jul.
Article in English | MEDLINE | ID: mdl-27345843

ABSTRACT

PURPOSE: Intensity-modulated radiation therapy (IMRT) has shown its interest for head and neck cancer treatment. In parallel, cetuximab has demonstrated its superiority against exclusive radiotherapy. The objective of this study was to assess the acute toxicity, local control and overall survival of cetuximab associated with different IMRT modalities compared to platinum-based chemotherapy and IMRT in the ARTORL study (NCT02024035). PATIENTS AND METHOD: This prospective, multicenter study included patients with epidermoid or undifferentiated nasopharyngeal carcinoma, epidermoid carcinoma of oropharynx and oral cavity (T1-T4, M0, N0-N3). Acute toxicity, local control and overall survival were compared between groups (patients receiving cetuximab or not). Propensity score analysis at the ratio 1:1 was undertaken in an effort to adjust for potential bias between groups due to non-randomization. RESULTS: From the 180 patients included in the ARTORL study, 29 patients receiving cetuximab and 29 patients treated without cetuximab were matched for the analysis. Ten patients (34.5%) reported acute dermal toxicity of grade 3 in the cetuximab group versus three (10.3%) in the non-cetuximab group obtained after matching (P=0.0275). Cetuximab was not significantly associated with more grade 3 mucositis (P=0.2563). There were no significant differences in cutaneous or oral toxicity for patients treated with cetuximab between the different IMRT modalities (P=1.000 and P=0.5731, respectively). There was no significant difference in local relapse-free survival (P=0.0920) or overall survival (P=0.4575) between patients treated with or without cetuximab. CONCLUSION: Patients treated with cetuximab had more cutaneous toxicities, but oral toxicity was similar between groups. The different IMRT modalities did not induce different toxicity profiles.


Subject(s)
Antineoplastic Agents/therapeutic use , Cetuximab/therapeutic use , Drug Eruptions/etiology , Head and Neck Neoplasms/therapy , Mucositis/etiology , Radiotherapy, Intensity-Modulated , Carcinoma, Squamous Cell/mortality , Carcinoma, Squamous Cell/pathology , Carcinoma, Squamous Cell/therapy , Chemotherapy, Adjuvant , Female , Head and Neck Neoplasms/mortality , Head and Neck Neoplasms/pathology , Humans , Male , Middle Aged , Neoplasm Recurrence, Local , Propensity Score , Prospective Studies
16.
Phys Rev Lett ; 115(9): 091302, 2015 Aug 28.
Article in English | MEDLINE | ID: mdl-26371638

ABSTRACT

We have searched for periodic variations of the electronic recoil event rate in the (2-6) keV energy range recorded between February 2011 and March 2012 with the XENON100 detector, adding up to 224.6 live days in total. Following a detailed study to establish the stability of the detector and its background contributions during this run, we performed an unbinned profile likelihood analysis to identify any periodicity up to 500 days. We find a global significance of less than 1σ for all periods, suggesting no statistically significant modulation in the data. While the local significance for an annual modulation is 2.8σ, the analysis of a multiple-scatter control sample and the phase of the modulation disfavor a dark matter interpretation. The DAMA/LIBRA annual modulation interpreted as a dark matter signature with axial-vector coupling of weakly interacting massive particles to electrons is excluded at 4.8σ.

18.
Bull Cancer ; 100(10): 983-97, 2013 Oct.
Article in French | MEDLINE | ID: mdl-24126183

ABSTRACT

Head and neck cancers are the fifth among the most common cancers in France. Two thirds of cases occur at an advanced stage. For advanced disease, progression-free survival, despite undeniable progress, remains below 50% at three years. The last 20 years have been marked by the necessity to identify situations where less intense surgery and/or radiotherapy and/or chemotherapy is possible without jeopardizing the prognosis, and situations where a therapeutic intensification is necessary and results in a gain in survival while better preserving function with less toxicity. French cooperative groups gathering radiation oncologists (GORTEC), surgeons (GETTEC) and medical oncologists or physicians involved in the management of systemic treatments in head and neck cancers (GERCOR) are now belonging to the INCa-labelled Intergroup ORL to deal with the challenges of head and neck cancers.


Subject(s)
Otolaryngology/organization & administration , Otorhinolaryngologic Neoplasms/therapy , Radiation Oncology/organization & administration , Chemoradiotherapy/methods , Chemoradiotherapy/trends , Disease-Free Survival , France , Humans , Induction Chemotherapy/methods , Lasers, Gas/therapeutic use , Medical Oncology/organization & administration , Organ Sparing Treatments/methods , Otolaryngology/methods , Otolaryngology/trends , Otorhinolaryngologic Neoplasms/mortality , Otorhinolaryngologic Neoplasms/pathology , Otorhinolaryngologic Neoplasms/virology , Papillomavirus Infections/complications , Paranasal Sinus Neoplasms/surgery , Phototherapy/methods , Radiation Oncology/methods , Radiation Oncology/trends , Retreatment/methods , Robotics/methods , Sentinel Lymph Node Biopsy
19.
Phys Rev Lett ; 111(2): 021301, 2013 Jul 12.
Article in English | MEDLINE | ID: mdl-23889382

ABSTRACT

We present new experimental constraints on the elastic, spin-dependent WIMP-nucleon cross section using recent data from the XENON100 experiment, operated in the Laboratori Nazionali del Gran Sasso in Italy. An analysis of 224.6 live days×34 kg of exposure acquired during 2011 and 2012 revealed no excess signal due to axial-vector WIMP interactions with 129Xe and 131Xe nuclei. This leads to the most stringent upper limits on WIMP-neutron cross sections for WIMP masses above 6 GeV/c², with a minimum cross section of 3.5×10(-40) cm² at a WIMP mass of 45 GeV/c², at 90% confidence level.

20.
Cell Transplant ; 22(1): 99-117, 2013.
Article in English | MEDLINE | ID: mdl-22507078

ABSTRACT

Amniotic fluid has drawn increasing attention in the recent past as a cost-effective and accessible source of fetal stem cells. Amniotic fluid-derived mesenchymal stem cells (AFMSCs) that display high proliferation rate, large spectrum of differentiation potential, and immunosuppressive features are considered optimal candidates for allogeneic repair of mesenchymal damaged tissues. In this study, ovine AFMSCs (oAFMSCs) isolated from 3-month-old sheep fetuses were characterized for their proliferation rate, specific surface antigen and pluripotency marker expression, genomic stability, and mesenchymal lineage differentiation during their in vitro expansion (12 passages) and after nucleofection. The high proliferation rate of oAFMSCs gradually decreased during the first six subculture passages while the expression of surface molecules (CD29, CD58, CD166) and of pluripotency-associated markers (OCT4, TERT, NANOG, SOX2), the in vitro osteogenic differentiation potential, and a normal karyotype were maintained. Afterwards, oAFMSCs were nucleofected with a selectable plasmid coding for green fluorescent protein (GFP) using two different programs, U23 and C17, previously optimized for human mesenchymal stem cells. Transfection efficiencies were ∼63% and ∼37%, while cell recoveries were ∼10% and ∼22%, respectively. Nucleofected oAFMSCs expressing the GFP transgene conserved their pluripotency marker profile and retained a normal karyotype and the osteogenic differentiation ability. Seven single clones with a GFP expression ranging from 80% to 97% were then isolated and expanded over 1 month, thus providing stably transfected cells with long-term therapeutic potential. The in vivo behavior of GFP-labeled oAFMSCs was tested on a previously validated preclinical model of experimentally induced Achille's tendon defect. The allotransplanted oAFMSCs were able to survive within the host tissue for 1 month enhancing the early phase of tendon healing as indicated by morphological and biomechanical results. Altogether these data suggest that genetically modified oAFMSCs might represent a valuable tool for in vivo preclinical studies in a highly valid translational model.


Subject(s)
Amniotic Fluid/cytology , Fetal Stem Cells/cytology , Green Fluorescent Proteins/genetics , Mesenchymal Stem Cell Transplantation/methods , Mesenchymal Stem Cells/cytology , Tendon Injuries/surgery , Transfection/methods , Amniotic Fluid/metabolism , Animals , Cell Growth Processes/physiology , Cell Proliferation , Cells, Cultured , Female , Fetal Stem Cells/metabolism , Green Fluorescent Proteins/metabolism , Immunohistochemistry , Male , Osteogenesis/physiology , Plasmids/genetics , Sheep , Tissue and Organ Harvesting/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...