Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Diabetes Technol Ther ; 24(8): 564-572, 2022 08.
Article in English | MEDLINE | ID: mdl-35325567

ABSTRACT

Objective: Artificial intelligence-based decision support systems (DSS) need to provide decisions that are not inferior to those given by experts in the field. Recommended insulin dose adjustments on the same individual data set were compared among multinational physicians, and with recommendations made by automated Endo.Digital DSS (ED-DSS). Research Design and Methods: This was a noninterventional study surveying 20 physicians from multinational academic centers. The survey included 17 data cases of individuals with type 1 diabetes who are treated with multiple daily insulin injections. Participating physicians were asked to recommend insulin dose adjustments based on glucose and insulin data. Insulin dose adjustments recommendations were compared among physicians and with the automated ED-DSS. The primary endpoints were the percentage of comparison points for which there was agreement on the trend of insulin dose adjustments. Results: The proportion of agreement and disagreement in the direction of insulin dose adjustment among physicians was statistically noninferior to the proportion of agreement and disagreement observed between ED-DSS and physicians for basal rate, carbohydrate-to insulin ratio, and correction factor (P < 0.001 and P ≤ 0.004 for all three parameters for agreement and disagreement, respectively). The ED-DSS magnitude of insulin dose change was consistently lower than that proposed by the physicians. Conclusions: Recommendations for insulin dose adjustments made by automatization did not differ significantly from recommendations given by expert physicians regarding the direction of change. These results highlight the potential utilization of ED-DSS as a useful clinical tool to manage insulin titration and dose adjustments.


Subject(s)
Diabetes Mellitus, Type 1 , Physicians , Artificial Intelligence , Blood Glucose , Diabetes Mellitus, Type 1/drug therapy , Humans , Hypoglycemic Agents/therapeutic use , Insulin/therapeutic use , Insulin, Regular, Human/therapeutic use
2.
J Diabetes Sci Technol ; 16(2): 364-372, 2022 Mar.
Article in English | MEDLINE | ID: mdl-33100030

ABSTRACT

AIMS: To compare insulin dose adjustments made by physicians to those made by an artificial intelligence-based decision support system, the Advisor Pro, in people with type 1 diabetes (T1D) using an insulin pump and self-monitoring blood glucose (SMBG). METHODS: This was a multinational, non-interventional study surveying 17 physicians from 11 countries. Each physician was asked to provide insulin dose adjustments for the settings of the pump including basal rate, carbohydrate-to-insulin ratios (CRs), and correction factors (CFs) for 15 data sets of pumps and SMBG of people with T1D (mean age 18.4 ± 4.8 years; eight females; mean glycated hemoglobin 8.2% ± 1.4% [66 ± 11mmol/mol]). The recommendations were compared among the physicians and between the physicians and the Advisor Pro. The study endpoint was the percentage of comparison points for which there was an agreement on the direction of insulin dose adjustments. RESULTS: The percentage (mean ± SD) of agreement among the physicians on the direction of insulin pump dose adjustments was 51.8% ± 9.2%, 54.2% ± 6.4%, and 49.8% ± 11.6% for the basal, CR, and CF, respectively. The automated recommendations of the Advisor Pro on the direction of insulin dose adjustments were comparable )49.5% ± 6.4%, 55.3% ± 8.7%, and 47.6% ± 14.4% for the basal rate, CR, and CF, respectively( and noninferior to those provided by physicians. The mean absolute difference in magnitude of change between physicians was 17.1% ± 13.1%, 14.6% ± 8.4%, and 23.9% ± 18.6% for the basal, CR, and CF, respectively, and comparable to the Advisor Pro 11.7% ± 9.7%, 10.1% ± 4.5%, and 25.5% ± 19.5%, respectively, significant for basal and CR. CONCLUSIONS: Considerable differences in the recommendations for changes in insulin dosing were observed among physicians. Since automated recommendations by the Advisor Pro were similar to those given by physicians, it could be considered a useful tool to manage T1D.


Subject(s)
Diabetes Mellitus, Type 1 , Physicians , Adolescent , Adult , Artificial Intelligence , Blood Glucose , Blood Glucose Self-Monitoring , Diabetes Mellitus, Type 1/drug therapy , Female , Glycated Hemoglobin/analysis , Humans , Hypoglycemic Agents , Insulin , Insulin Infusion Systems , Male , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...