Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Language
Publication year range
1.
Heliyon ; 10(12): e33208, 2024 Jun 30.
Article in English | MEDLINE | ID: mdl-39021975

ABSTRACT

Hyperspectral imaging has emerged as an effective powerful tool in plentiful military, environmental, and civil applications over the last three decades. The modern remote sensing approaches are adequate for covering huge earth surfaces with phenomenal temporal, spectral, and spatial resolutions. These features make HSI more effective in various applications of remote sensing depending upon the physical estimation of identical material identification and manifold composite surfaces having accomplished spectral resolutions. Recently, HSI has attained immense significance in the research on safety and quality assessment of food, medical analysis, and agriculture applications. This review focuses on HSI fundamentals and its applications like safety and quality assessment of food, medical analysis, agriculture, water resources, plant stress identification, weed & crop discrimination, and flood management. Various investigators have promising solutions for automatic systems depending upon HSI. Future research may use this review as a baseline and future advancement analysis.

2.
J Pharm Bioallied Sci ; 16(Suppl 2): S1628-S1632, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38882757

ABSTRACT

Objectives: This study intended to assess the level of awareness and attitude toward otitis externa (OE) and specific limitations that counter the attempts to uplift the understanding and notion related to OE among the general population of Saudi Arabia. Methods: A cross-sectional quantitative study using a questionnaire was done via Google Forms between May 2023 and July 2023. The scoring method was used to determine the participant's awareness or attitude; participants who scored >50% were considered aware or to have a good attitude. Results: Approximately 52.2% had a good attitude toward the OE, and majority were willing to visit healthcare professionals (81%) to provide care and receive proper education during office visits (80.1%). Of all the participants, 69%, 33.4%, and 30.8% suggested that a lack of awareness, cost, and health insurance, respectively, might prevent patients from seeking a healthcare professional. Only 10.9% of participants demonstrated good awareness (score >13) of outer ear inflammation. Conclusion: The findings indicate a poor level of awareness regarding OE, and a positive attitude toward seeking healthcare, with the majority recommending professional visits and relying on healthcare professionals for information.

3.
J Pharm Bioallied Sci ; 16(Suppl 2): S1623-S1627, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38882814

ABSTRACT

Introduction: Sedentary behaviors have been on the rise, potentially exacerbated by lockdowns, remote work, and lifestyle shifts during the pandemic, emphasizing the need to assess public awareness regarding associated health risks. This study investigated the knowledge and awareness levels of the Saudi population regarding sedentary lifestyle risk factors in the post-COVID-19 era. Methodology: This cross-sectional study included 400 participants and was conducted from May 2023 to July 2023 using a questionnaire distributed randomly through social media in multiple regions of Saudi Arabia. Results: The majority of the participants were females (57.1%), aged 15-25 years (54.3%), had a higher educational degree (65.4%) and were single (62%). Most (62%) of the participants reported declined/physical activity levels in the post-COVID-19 era. Our study found that 65% of the participants had increased usage of online shopping and delivery applications after the pandemic, and a significant portion (66%) had less than 150-300 min of moderate aerobic activity weekly. Barriers, such as bad weather and insufficient time for exercise, had significant impacts. Conclusion: This study provides valuable insights into the Saudi population's demographic characteristics, knowledge, and behaviors related to physical activity and health.

4.
J Pharm Bioallied Sci ; 16(Suppl 2): S1663-S1666, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38882840

ABSTRACT

Background: The thalamus, located in the diencephalon, regulates emotions and memories. If there is a problem in this area of the brain, it can cause an amnestic syndrome characterized by difficulties in remembering and recognizing things. The objective of this study was to identify changes in the volume of the thalamus while contrasting them among individuals with depression. Materials and Methods: The study involved measuring the volumes of the white matter of the thalamus in 79 patients with depression (42 males and 37 females) between 20 and 40 years (24 ± 5.51). This was compared to a control group of 53 individuals (24 ± 4.91) consisting of 29 males and 24 females, who were comparable in terms of sex and age. The measurements were taken employing BrainSuite version 18a. 021 Win 64bit software on a Philips 1.5 Tesla Magnetom Avanto Vision System magnetic resonance imaging (MRI). The Magnetization Prepared Rapid Acquisition (MPRA) was utilized to acquire three-dimensional images with T1 weighting. Results: The volume of white matter in the respective right and left thalamus was 5.09 cm3 and 4.58 cm3 (±standard deviation (SD) = 6.43 and 4.74) among individuals with depression. In the control group, the volume of white matter in the right and left thalamus was 3.66 cm3 and 4.16 cm3 (±SD = 3.99 and 5.06), respectively. The P-value is more than 0.05. The average volume of white matter in the right and left thalamus of females with depression and controls was 6.47 cm3 and 6.77 cm3 (with SD of 4.17 and 4.3), and 3.25 cm3 and 3.13 cm3 (with SD of 6.55 and 6.77), respectively. Conclusions: Our data suggest that individuals with depression exhibit an augmentation in the white matter of the thalamus, particularly in female patients where there is an upsurge in white matter volume. Depression appears to be linked to a decrease in volume on the left side of the brain.

5.
PLoS One ; 19(6): e0305524, 2024.
Article in English | MEDLINE | ID: mdl-38900804

ABSTRACT

This paper presents a compact 5G wideband antenna designed for body-centric networks (BCN. The single element antenna design includes a simple T-shaped radiator patch with ring shaped ground plane and transformer impedance feedline. First, the antenna was simulated in free-space, and its resonant frequency is found to be 27 GHz, falling within 5G's n261 band. The proposed single radiator antenna has a size of 23.375 mm3, and it offers a wide impedance bandwidth of 2.0 GHz (26-28 GHz). Parametric studies demonstrated that by increasing the length of slots in patch, the antenna frequency can be reduced further. Single radiator antenna is used as 8-element MIMO structure. Parallel adjacent antenna in X-direction has minimal coupling effect, whereas antenna placed in Y-direction has high coupling effect. Thus, coupling is reduced by etching a wall of slots in ground plane. It alters the surface current interference in Y-direction and limits the coupling effect. The antenna is investigated to use in body area network applications. To evaluate its on-body performance, an equivalent body model is virtually developed. The on-body performance is assessed by placing the antenna in close proximity to body model. Stable and robust performance is achieved for the on-body operation. At the resonant point, the antenna exhibits a reflection coefficient of -30 dB (free space) and -40 dB (on-body), high isolation of above 20 dB between adjacent radiators and above 30 dB for other radiators. Antenna has stable performance for different body tissues and on the non-planar structures. Bidirectional radiation pattern with gain of 2.53 dB and broadside type orientations with gain of 4.64 dB are achieved for free space and on body operations respectively. low specific absorption rate makes antenna safe for health care devices. Further, diversity performance is measured in terms of envelope correlation coefficient (ECC), and diversity gain (DG). Maximum Value of ECC is 0.005 and minimum value DG is 9.97 at 27 GHz which confirms the excellence of antenna for MIMO applications.


Subject(s)
Wireless Technology , Wireless Technology/instrumentation , Equipment Design , Humans
6.
PLoS One ; 19(3): e0296800, 2024.
Article in English | MEDLINE | ID: mdl-38547256

ABSTRACT

Solar energy generation requires photovoltaic (PV) systems to be optimised, regulated, and simulated with efficiency. The performance of PV systems is greatly impacted by the fluctuation and occasionally restricted accessibility of model parameters, which makes it difficult to identify these characteristics over time. To extract the features of solar modules and build highly accurate models for PV system modelling, control, and optimisation, current-voltage data collecting is essential. To overcome these difficulties, the modified particle swarm optimization rat search algorithm is presented in this manuscript. The modified rat search algorithm is incorporated to increase the PSO algorithm's accuracy and efficiency, which leads to better outcomes. The RSA mechanism increases both the population's diversity and the quality of exploration. For triple diode model of both monocrystalline and polycrystalline, PSORSA has showed exceptional performance in comparison to other algorithm i.e. RMSE for monocrystalline is 3.21E-11 and for polycrystalline is 1.86E-11. Similar performance can be observed from the PSORSA for four diode model i.e. RMSE for monocrystalline is 4.14E-09 and for polycrystalline is 4.72E-09. The findings show that PSORSA outperforms the most advanced techniques in terms of output, accuracy, and dependability. As a result, PSORSA proves to be a trustworthy instrument for assessing solar cell and PV module data.


Subject(s)
Algorithms , Solar Energy , Animals , Rats , Sunlight
7.
Heliyon ; 10(4): e26398, 2024 Feb 29.
Article in English | MEDLINE | ID: mdl-38404786

ABSTRACT

Brain implantable wireless microsystems has potential to treat neurological diseases and maintain the quality of life. Highly efficient miniaturized antenna is the fundamental part of BID (brain implantable device) for reliable signaling of data through dissipative intracranial material. In this paper, a patch antenna with L-shaped defected ground is demonstrated. L-shaped radiator contributed to achieve the resonance at 2.45 GHz industrial scientific and medical (ISM) band. Antenna size is reduced to 10 × 10 × 0.25 mm3. The proposed L-shaped ground plane geometry is contributing in improving the radiation performance. |S11| value shifts from 15 dB to 30 dB after modifying the ground plane. Proposed structure attained the gain of -14 dBi when located between the Dura and CSF layers at the depth of 12 mm in human brain model. Full wave simulated antenna prototype is fabricated and measured for performance verification. Impedance bandwidth of 270 MHz and broadside radiation pattern (for transferring maximum electromagnetic energy away from tissue) are maintained by the proposed antenna. Brain tissue safety is ensured by specific absorption rate which is 0.709 W/kg and in compliance with the safety limits of 1.6 W/kg for 1-g averaged tissue. Proposed antenna structure is the promising candidate for medical implant technology.

8.
Micromachines (Basel) ; 14(12)2023 Nov 29.
Article in English | MEDLINE | ID: mdl-38138341

ABSTRACT

The increasing prevalence of the Internet of Things (IoT) as the primary networking infrastructure in a future society, driven by a strong focus on sustainability and data, is noteworthy. A significant concern associated with the widespread use of Internet of Things (IoT) devices is the insufficient availability of viable strategies for effectively sustaining their power supply and ensuring their uninterrupted functionality. The ability of RF energy-harvesting systems to externally replenish batteries serves as a primary driver for the development of these technologies. To effectively mitigate concerns related to wireless technology, it is imperative to adhere strictly to the mandated limitations on electromagnetic field emissions. A TA broadband polarization-reconfigurable Y-shaped monopole antenna that is improved with a SADEA-tuned smart metasurface is one technique that has been proposed in order to accomplish this goal. A Y-shaped printed monopole antenna is first taken into consideration. To comprehend the process of polarization reconfigurability transitioning from linear to circular polarization (CP), a BAR 50-02 V RF PIN Diode is employed to shorten one of the parasitic conducting strips to the ground plane. A SADEA-driven metasurface, which utilizes the artificial intelligence-driven surrogate model-assisted differential evolution for antenna synthesis, is devised and positioned beneath the radiator to optimize performance trade-offs while increasing the antenna's gain and bandwidth. The ultimate prototype achieves the following: an impedance bandwidth of 2.58 GHz (3.27-5.85 GHz, 48.45%); an axial bandwidth of 1.25 GHz (4.19-5.44 GHz, 25.96%); a peak gain exceeding 8.45 dBic; and when a highly efficient rectifier is integrated, the maximum RF-DC conversion efficiency of 73.82% and DC output of 5.44 V are obtained. Based on the results mentioned earlier, it is considered appropriate to supply power to intelligent sensors and reduce reliance on batteries via RF energy-harvesting mechanisms implemented in hybrid wireless applications.

9.
Int. j. morphol ; 35(4): 1276-1279, Dec. 2017. graf
Article in English | LILACS | ID: biblio-893127

ABSTRACT

SUMMARY: Variation in the morphology of the extensor pollicis longus muscle is very rare. The muscle is considered as one of the deep group of dorsal forearm muscles. It passes through the dorsal radiocarpal ligament in a detached compartment. It inserts at the base of the distal phalanx of the thumb. The muscle might have double tendons where they run either in one, or in separate compartments. In this study, we report an extremely rare condition for a 38-year-old male where some of the tendon fibers split at the base of the proximal phalanx and the two tendons insert at the sides of the base of the distal phalanx. We also noticed a high range of hyperextension where the action was painless and showed no sign of discomfort. We believe that the way the tendons get inserted might have a role in this wide range of extension.


RESUMEN: La variación en la morfología del músculo extensor largo del pulgar es muy rara. Es considerado perteneciente al grupo profundo de los músculos del dorso del antebrazo. Su tendón pasa a través del ligamento radiocarpiano dorsal en un compartimiento separado. Se inserta en la base de la falange distal del pulgar. El músculo puede tener tendones dobles que pasan a través de un solo compartimiento, o en compartimentos separados, del ligamento radiocarpiano dorsal. En este estudio se reporta una variación extremadamente rara en un hombre de 38 años de edad, donde algunas de las fibras del tendón se dividen en la base de la falange proximal y los dos tendones se insertaban a los lados de la base de la falange distal del pulgar. También observamos un alto grado de hiperextensión siendo la acción indolora y no mostrando ningún signo de malestar. Creemos que la forma en que los tendones se insertan podrían tener un papel en este amplio rango de extensión.


Subject(s)
Humans , Male , Adult , Finger Joint/abnormalities , Muscle, Skeletal/abnormalities , Tendons/abnormalities , Anatomic Variation
SELECTION OF CITATIONS
SEARCH DETAIL