Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Clin Chem Lab Med ; 62(7): 1393-1401, 2024 Jun 25.
Article in English | MEDLINE | ID: mdl-38205624

ABSTRACT

OBJECTIVES: Serum angiotensin-converting enzyme (ACE) is the only biomarker routinely used in the laboratory diagnostics of sarcoidosis, and ACE inhibitor (ACEi) drugs are among the most prescribed drugs worldwide. Taking ACEi can mislead medical teams by lowering ACE activity, delaying diagnosis and giving a false impression of disease activity of sarcoidosis. We aimed to develop a simple method to detect the presence of ACEi drugs in samples, to investigate the ACEi medication-caused interference and consequences in a retrospective study. METHODS: ACE activity and the level of ACE inhibition were determined for 1823 patients with suspected sarcoidosis. These values were compared with the therapeutic information at the first and follow-up visits. RESULTS: A total of 302 patients had biochemical evidence of an ACEi drug effect during diagnostic ACE activity testing. In their case, ACE activity was significantly lower (median(IQR): 4.41 U/L(2.93-6.72)) than in patients not taking ACEi (11.32 U/L(8.79-13.92), p<0.01). In 62 sarcoidosis patients, the ACEi reduced ACE activity to the reference range or below. Only in 40 % of the cases was the medication list recorded in the outpatient chart and only in 3 cases was low ACE activity associated with ACEi use. 67 % of the repeated ACE activity measurements were also performed during ACEi therapy. CONCLUSIONS: Our study revealed that the use of ACEi is common in patients with suspected sarcoidosis. The ACE activity lowering effect of ACEi drugs may escape the attention of medical teams which can lead to diagnostic errors and unnecessary tests. Nevertheless, these pitfalls can be avoided by using a method suggested by our team.


Subject(s)
Angiotensin-Converting Enzyme Inhibitors , Peptidyl-Dipeptidase A , Sarcoidosis , Humans , Angiotensin-Converting Enzyme Inhibitors/therapeutic use , Sarcoidosis/drug therapy , Sarcoidosis/diagnosis , Sarcoidosis/blood , Male , Female , Middle Aged , Retrospective Studies , Peptidyl-Dipeptidase A/blood , Adult , Biomarkers/blood
2.
Clin Chem Lab Med ; 56(7): 1117-1125, 2018 06 27.
Article in English | MEDLINE | ID: mdl-29425104

ABSTRACT

BACKGROUND: Serum angiotensin-converting enzyme (ACE) activity determination can aid the early diagnosis of sarcoidosis. We aimed to optimize a fluorescent kinetic assay for ACE activity by screening the confounding effects of endogenous ACE inhibitors and interfering factors. Genotype-dependent and genotype-independent reference values of ACE activity were established, and their diagnostic accuracies were validated in a clinical study. METHODS: Internally quenched fluorescent substrate, Abz-FRK(Dnp)P-OH was used for ACE-activity measurements. A total of 201 healthy individuals and 59 presumably sarcoidotic patients were enrolled into this study. ACE activity and insertion/deletion (I/D) genotype of the ACE gene were determined. RESULTS: Here we report that serum samples should be diluted at least 35-fold to eliminate the endogenous inhibitor effect of albumin. No significant interferences were detected: up to a triglyceride concentration of 16 mM, a hemoglobin concentration of 0.71 g/L and a bilirubin concentration of 150 µM. Genotype-dependent reference intervals were considered as 3.76-11.25 U/L, 5.22-11.59 U/L, 7.19-14.84 U/L for II, ID and DD genotypes, respectively. I/D genotype-independent reference interval was established as 4.85-13.79 U/L. An ACE activity value was considered positive for sarcoidosis when it exceeded the upper limit of the reference interval. The optimized assay with genotype-dependent reference ranges resulted in 42.5% sensitivity, 100% specificity, 100% positive predictive value and 32.4% negative predictive value in the clinical study, whereas the genotype-independent reference range proved to have inferior diagnostic efficiency. CONCLUSIONS: An optimized fluorescent kinetic assay of serum ACE activity combined with ACE I/D genotype determination is an alternative to invasive biopsy for confirming the diagnosis of sarcoidosis in a significant percentage of patients.


Subject(s)
Enzyme Assays/methods , Peptidyl-Dipeptidase A/blood , Peptidyl-Dipeptidase A/standards , Sarcoidosis/diagnosis , Adult , Aged , Female , Genotype , Humans , Male , Middle Aged , Peptidyl-Dipeptidase A/genetics , Polymorphism, Genetic , Reference Values
SELECTION OF CITATIONS
SEARCH DETAIL
...